Loading...
HomeMy WebLinkAboutBLD2007-01111 Cancelled Addition - BLD Permit / Conditions - 7/18/2007 Line 360)427- 262 ection MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phonpe: (360)427`9670,ext7352 `r{ Mason County Bldg. III 426 W. Cedar P.O Box 186 lrfi Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2007-01111 OWNER: TYSON WILLIAMS CONTRACTOR: LICENSE: EXP: RECEIVED: 6/21/2007 SITE ADDRESS: 191 E VILLAGE VIEW DR ALLYN ISSUED: 7/18/2007 PARCEL NUMBER:,.1,22205000093 EXPIRES: 1/18/2008 LEGAL DESCRIPTION: LAKELAND VILLAGE 1 TR 93 PROJECT DESCRIPTION: DIRECTIONS TO SITE: ADDITION ON SFR STATE ROUTE 3, L ON L E AND DR, L ON VILLAGE VIEW LN TO SITE ADDRESS O HE LEFT ID General Information Construction &Occupancy Info 4tion Square Footage Information No. of Bedrooms: 1 T e of ns r.: V- Type of Use: : F Insp.Ar No.of Bathrooms: 1 cc ro p R-3 Lot Size: Deck: 150 Type of Work: ADD Fire st.: No.of Stories: Oc Lo Building: Valuation: Building Heigh 1 cc Stat Basement: addition 672 Manufactured Home Informaltion Setb ck In r io Shoreline&Planning Information Make: Length: Ft. yFrt: 20.0 Shoreline: Ft. Water Body: SEPA?: 0.0 Ft. Slope: Ft. Shoreline DesiModel: Width: Ft. 19.0 Ft. g•: Not Applicable Year: Serial No.: 5.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qt . Type Qty. Type By Date Amount Receipt Lavatories 2 Gas Outlets 2 Plan Check Fee GMM 6/21/2007 $427.54 B12007000 Showers 1 Propane Tank 1 Planning Review Fee GMM 6/21/2007 $170.00 b12bb7bbb Water Closets (Toilets) 1 Ventilation Fan 1 Building State Fee RTB 7/6/2007 $4.50 S22bb70b0 Bath Tubs 1 Propane Stove 1 Building Permit Fee RTB 7/6/2007 $657.75 § bb7bbb Mechanical Fee RTB 7/6/2007 $128.00 S22007000 Mechanical Base Fee RTB 7/6/2007 $25.30 S220070b0 Plumbing Fee RTB 7/6/2007 $38.50 S22007000 Plumbing Base Fee RTB 7/6/2007 $22.00 S22007000 EH Plan Review TW 7/6/2007 $35.00 S22007000 Total $1,508.59 BLD2007-01111 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2007-01111 r . CONDITIONS FOR BLD2007-01111 1) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. x �J 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 3) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where Xch roads c nnect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. 4) This parcel is located in a smoke management zone. Please contact a fire warden at(360)427-9670 ext. 459 for further information. X 5) All other r-ecessary permits from Mason County, Washington State and/or Federal Agencies that are re_quire for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X � � 6) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Xepartme . nor p any/further inspections being performed or approvals granted. 7) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. x �. i 8) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removel of approved d cuments will result in failure of required building inspections. x s? 9) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X BLD2007-01111 Please referto the following pages for conditions of this permit. 2 of 4 10) , , .The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then • approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building 'Deeparenx prior to any further inspections being performed or approvals granted. // 11) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window (Max U-Factor):0.40, Skylight (Max U-Factor):0.58, Doors (Type/Max U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X �.��2�✓ 12) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X Z4�ty 13) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocat' n. X CL4, 14) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 15) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 'Z.- , Z�. 16) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be,made prior to requesting additional inspections. X , 17) All property lines shall be clearly identified at the time of foundation inspection. X BLD2007-01111 Please referto the following pages for conditions of this permit. 3 of 4 18) All building permits shall have a final inspection performed and approved �y the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. y X 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 20) Pressure 'reated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X Zvi.6,% 21) By defini,ion, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. � X J--�L--I1.- 22) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X 7- . y This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. z/� OWN ER OR AGENT: s "� DATE: BLD2007-01 1 11 Please referto the following pages for conditions of this permit. 4 of 4 i/vLLJ"A.L v YiJA L'ai�1 LTiL'1\1 Ju LA l iVl\ iVLV Vjv o x \Qw /e4f REQUEST TAKEN BY G- TIME f DATE OF INSPECTION O � " TODAY'S DATE r_ / l DATE INSPECTION IS REQUESTED J/ NAME ON PERMIT SITE ADDRESS PERMIT# �" �- TYPE OF PERMIT TELEPHONE #, NAME / y '1 i _ ✓C INSPECT.AREA TYPE OF INSPECTION: C _FOOTING INT.SHEAR WALL NAILING HOLES FOUNDATION FINAL PROGRESS SLAB INSULATION MOBILE HOME FOOTING OTHER SLAB ROUGH-IN PLUM MOBILE HOME SET-UP FRM/PLUMB/MECEVPEN MOBILE HOME FINAL INSULATION WOODSTOVE/PROPANE CONFIRMED DATE -CONTACT TIME tsUlLLll�li L1LYAl�11Vli�.lr 1 106YLU'llUiN KLVUEST 16 REQUEST TAKEN B TIME ;Z^ DATE OF INSPECTION 7 TODAY'S DATE '` - DATE INSPECTION IS REQUESTED / �e�T2_--,,:. NAME ON PERMIT SITE ADDRESS PERMIT TYPE OF PERMIT c`i 7�"► TELEPHONE #, NAME �' v�S�� INSPECT. AREA TYPE OF INSPECTION: FOOTING INT.SHEAR WALL NAILING HOLES FOUNDATION FINAL PROGRESS SLAB INSULATION MOBILE HOME FOOTING OTHER " SLAB ROUGH-IN PLUM MOBILE HOME SET-UP _S�FRM/PLUMB/MECH/PEN MOBILE HOME FINAL INSULATION WOODSTOVE/PROPANE %a ./ CONFIRMED DATE CONTACT L TIME BUILDING DEPARTMENT INSPECTION REQUEST REQUEST TAKEN BY TIME DATE OF INSPECTION TODAY'S DATE_ �'Z7-C DATE INSPECTION IS REQUESTED NAME ON PERMITa7-J SITE ADDRESS171 PERMIT # ` Q I I 1 TYPE OF PERMIT TELEPHONE #, NAME INSPECT. AREA TYPE OF INSPECTION: FOOTING INT.SHEAR WALL NAILING HOLES FOUNDATION FINAL PROGRESS SLAB INSULATION MOBILE HOME FOOTING OTHER SLAB ROUGH-IN PLUM MOBILE HOME SET-UP (iFRM/PLUMB/MECH/PEN MOBILE HOME FINAL _�INSULATION WOODSTOVE/PROPANE t. CONFIRMED DATE CONTACT �� v 1 TIME �' BUILDING DEPARTMENT INSPECTION REQUEST REQUEST TAKEN BY TIME 12­e 4,*� DATE OF INSPECTION TODAY'S DATE ' _ DATE INSPECTION IS REQUESTED NAME ON PERMIT SITE ADDRESS PERMIT # `�- / TYPE OF PERMIT.,� TELEPHONE #, NAME 'Y % INSPECT.AREA TYPE OF INSPECTION: FOOTING YNT.SHEAR WALL NAILING HOLES FOUNDATION FINAL PROGRESS SLAB INSULATION MOBILE HOME FOOTING OTHER SLAB ROUGH-IN PLUM MOBILE HOME SET-UP Y FRM/PLUMB/MECH/PEN MOBILE HOME FINAL INSULATION WOODSTOVE/PROPANE CONFIRMED(. DATE CONTACT pie C�rv�Y�y�x���f TIMES° - (2/17C200O Phyllis Burnison - Inspection request for: BLD2007-01 111 ------ —----- Pagel � From: «chi|nonxiUiama@yahoo.nom> To: <pib@�zn.m000nmm.us» Date: 2/17/20008:20AM Subject: Inspection request for: 8LD20O7'01111 7h k v�,e(a� Date inspection Requested: 02/18/0S r y Name on Permit: TYSONWILLIAMS Site Address: 101 E VILLAGE VIEW ORALLYN Permit Number: BLD200T'01111 Requentoru Name: Apri|JoneWilliams Phone Number: 360G482187 ~ |napeotionTypo: SitaB Comment\Other Type: sop - o CONCRETE..__. MECHANICAL MANUFACTURED HOME CD Rite Footings I Setbacks Gas Piping Ribbons o 7,Te-r7or�Date By Interior-Date By Data By Exterior Date&Z' B Y/2/,>U Exterior-Date By I set.up ii— Point Lc--1 INSULAfici 1"olated Foctings BG ULATION Cate By !SLAB INS Date By ch Date By FIRE DEPARTMENT 0 Foundation Walls Floors Dale By z Date Data L�y DECKS FRAMING 'wales Date By Date B PROPANE TANKS PLUMBING Vault Date By late Sy OTHER GroundwotU Attic Type: Date y Data By B -I Data By 01W.V DRYWALL Type: Date 15"- 7-7- 8 Int.Brace Wall Date By lA date - FINAL INSPECTION Water Li Fife S 0ato By Date By Date By C)C) Pass or Request Inspect. 6 Type of Insp. Fail Date Date Done By Comments (D '10t;e PIV 0 CD 0 CD 0 BLAding Permit MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location /!a jZ1c046-;C- Lx1,674c.,) This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection 8, OK to ❑ This is not a co plete inspection Department s4� Date —��'��y Inspector ,L1S moo * No *T Mo *V THlmw& T ' ,*w