HomeMy WebLinkAboutBLD2024-00113 - BLD CD Environmental Health Review - 2/1/2024 MASON COUNTY COMMUNITY SERVICES Permilaoa - JJ3
PERMITASSISTANCECENTER:
.BUIL NG•P"NNING.PUBLICNEN.TH-FIREMARSHAL
615 W.NCw StleeLSMMn.WA°B5H
PAon.a"�'„'o,'z7�67-F61';Ems;Pat)' :�69 ENVIRONMENTAL
BUILDING PERMIT APPLICATIONI'I EALTH
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Lermar NoMwest LLC NAME: Lennar Northwest,LLC
MAILING ADDRESS: 33455 6th eve S.UBit 1-H MAII.WG ADDRESS:33455 6th ave S,Uadt 1-B
C7TY:Federel WaY -STATE.-WA ZIP: 98003 CITY:Federal Way STATE:WA ZIP: 98003
PHONE#1: (253)30&0265 PHONE: CELL:�
/1 PHONE#2: EMAIL: Laoren.FefnisALeratatI om
DJ EMAIL:Lauren.Fafiisfi*Le .tom L&I REG#LENNANL783JO EXP. 03/18/24
PRIMARY CONTACT: OWNER CDNTRALTOR❑ lill9
NAME Lauren Fafnis,Aglfcr Lennar EMML Ieuran.pembll.nner.mm
MMLING AOORE55 334536�i ave 5.Un1t 1-e Ory Few nATB WA Up
PHONE125313oe-026s CELL_
PARCEL INFORMATION:
OPARCEL NUMBER(12 Digit Number) 12328-514)0127 ZONING
LEGAL DESCRIPTION(Abbm,,,W) Olympic Ridge FIRE DISTRICT
SITE ADDRESS 131 HE Belau Station Dr CII'1'
„s DIRECTIONS TO SHE ADDRESS
ISTHEPRWECTWI'FIIBi3o11FTOFSIAPE(3)GREATERTNANI4A: YESD NO® SNOWLOAD:$$. W
I IS PROPERTY WITHIN 200 FT OFTNE FOLLOWING: IClwimwagMsyJ:
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONALRUNOFFD STREAM❑
^� TYPE OF WORK: NEW® ADDITION❑ ALTERATION❑ REPAIR❑ OTHER M
USE OF STRUCTURE(xemtraa,aemge,c oo lemg,pa)New SFR usim aooroved stock plan#bM-na Plan 104]MF GL
1SUSE: PRIMARY[] SEASONAL❑ NUMSEROFBEDROOMS 3 NUMBFROFBATHROOMS 2
HEATED STRUCTURE! YES Praan Bl¢J❑ YES fBmrPl fiahal® NOD
DESCRIBE WORK New Single Family Residence heeled and aas°aeunheatd
�J SQUARE FOOTAGE:&.,l
T In FLOOR 1021 s9.ft. 2NDFLOOR aS.ft. 3RDFLOOR aIft BASEMENT N.ft
DECK_al COVEREDDBC-iQ Nft STORAGE p.ft OTHERl ft
n GARAGE 3W aq.I Amached® DemcAM❑ CARPORT °q.ft Aoachedo Demrhed❑
v MANUFACTURED HOME INFORMATION: a4 COPIES OF THE FLOOR PLAN REQUIRED-
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENYUIIQ TALHEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER® / NEW EXISTING
PLUMBING IN STRUCTURE? YES® NO❑ If^r,,mmeM1 completed Wmer Adeemary Form
PERI[MnER/FOUNDATION DRAINS PROPOSED? YES R NOD EXISTING SQ.FT. 1470
EXISTING BEDROOMS PROPOSED BEDROOMS TOTALBEDROOMS
QYr�RacMrvamefoea Bin awniamm minem.ale exomrauon mey rcslm In aasapwort amaw pemvl rewonm.xxnvneegemem mars bXy
!]rWe E¢UW.Ibtlme Mn heerUMereM NMm Declare IXarlapneMbrecWeImle PormX end 10 EOMevvrk eepropoae0 o naw
MMWpmnia®onhomall Dee rfosrarmpm IdM,.a one eesemem Mderor peN¢e m -ICre1a-at prolem d.rothrorroon
aced rleEae.mpaeade Bad The Ml TIN,of ieemrele antl or+^I+eraAaYeeaW Memn Lanry aaess to rXe•Hove desvlC¢d pmpNly
nC or I- e)la mN¢WBndrusaeral r. penni 0 I tafilpnMmmae null6 xre RvuM1 or autlwved mn5mcdion 15 nMmmme^SO vi1X611m
Nya abmneWCWn xvm rc susperAed Im a Poripd m Nan dayb.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.IMAEON
COUNTY CODE lCil 21
X L6ueaiL FQ�irb 12/11/2023
$a3nrum al ER IMual ha agnetl bvgelWMERI Data
DEPARTMENTALREVIEW APPROVED DATE DENTED DATE TAGSINOTES/COND]TIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH Z
TCE 7INSFALL TEMP. CONST. ENTRANCE BUILDING SETBACKS:
EH APPROVED F 1R 10' sDe s' ": 10•
TSS =INSTALL TEMP. SOIL STOCKPILE Rho.Tlo, a Owtr2014
15'12'45E 69.4 ' I Z
PROPOSED - -
\______________344—__--, I I
i
CONTOURS _ l _
------342------- I < �
_-340— ---(' -
PUNic sewer and water
-T.
---334- -h1 \\ has Meemm mrenr,evaom,a aaem
BSBL 1 \ io Prom wremmm.
(TYP) I 1 \\ b vw.sieeuor acceewry n,ucr„rcs a,m slam for not
® , W Seer���aro releer
I j Rev vema reerror eaeeeory wum�res acn rO rrrcuw me
I n ewaneo tee.
I vreer r.v wre.lO i»r.
PATIO j ' x J
1
16.5' 17.96'
35'
EAVE HS 12-, III o
BUILDING PROPOSED
ENVELOPE SFR n wma
n
a v nvPeoveO
� 1047MF I M45CN000RIV�C�FIANNiNG
ry � SCOR ROtDVA1eD
16'E L INSTALL SILT FENCE,
z CONCRETE STRAW WATTLE, OR
16.5' DRNEWAY PORCH a FUNCTIONALLY EQUIVALENT
SS STUB :. 1ALk / ?7B' v ADA RAMP
..
(TYP.)
STORM
�i STUB — - FIRE s^ SOIL AMENDMENT NOTE:
PWR ti❑ KE HYDRAN -�\ SEE BMP T5.13 'POST CONSTRUCTION
VAULT SOIL OUALTIY AND DEPTH', WSDOE
° . STORMWATER MANAGEMENT MANUAL
1 '12 45 W 29.47 FOR WESTERN WASHINGTON.
SV N \ POWER TRANSFORMER SETBACK NOTES:
1. MINIMUM DISTANCE FROM ANY POWER
-- --- --- L-6288' TRANSFORMER TO ANY DOOR, WINDOW, ON ALL
R�40 W, NON-COMBUSTIBLE MATERIALS SHALL BE
8-FEET.
NE BELFAIR ST TM M — A-W023e 2. MINIMUM DISTANCE FROM ANY POWER
TRANSFORMER TO ANY COMBUSTIBLE WALLS OR
LOT SIZE = 7,644 SF ROOF SHALL BE 10-FEET.
SEPARATION NOTE:
IMPERVIOUS ANY PORTIONS OF STRUCTURES WITH LESS THAN
TOTAL IMPERVIOUS: 2,022 SF (26.5%) 10-FEET OF SEPARATION SHALL BE FIRE RATED.
ROOF: 13 28 SF
DRIVEWAY: ,6 2 SF FLAT WORK NOTE:
WALK: 33 SF LOT COVERAGE = 1,628 SF (21.3%) FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PATIO: 9 SF (INCLUDES EAVES) PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
°' "Mm'ef EmboPm2° '° LENNAR NORTHWEST LLC.
21885 Fro4 r 40
Barghausen OLYMPIC RIDGE
Sheet Consulting Engineers,Inc.
Qe,,, OMhBP HOMESITE 127
1821572nd Avenue South PARCEL NO. 12328-51-00127
Kent W 98032
of
ooe 12/11/23 425251.6M bn9heurnwm 131 NE BELFAIR STATION DR, BELFAIR, WA
RIe:P:\210u0.\21885\rot\218e5-0yrepc Ridp-Plot %ns.d.y Plot Deter e:12/11/2023 1:54 PM DORMS