HomeMy WebLinkAboutBLD2015-01062 Solar - BLD Permit / Conditions - 12/28/2015 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext.352 Mason County Bldg. III 426 W. Cedar Shelton, WA 98584 1R44 RESIDENTIAL BUILDING PERMIT BLD2015-01062 OWNER: GARY MAXWELL CONTRACTOR: ARTISAN ELECTRIC, INC 206-557-4215 or 206-489-9536 LICENSE: ARTISE19361-1 EXP: 6/2 RECEIVED: 12/28/2015 SITE ADDRESS: 150 E WESTLAKE WY ALLYN ISSUED: 12/28/2015 PARCEL NUMBER: 122195000024 EXPIRES: 6/28/2016 LEGAL DESCRIPTION: LAKELAND VILLAGE 7 LOT: 24 PROJECT DESCRIPTION: DIRECTIONS TO SITE: PHOTOVOLTAIC ROOF TOP MOUNTED SYSTEMS (SOLAR) FROM HWY 3 HEAD WEST ON E LAKELAND DR HEAD EAST ON WESTLAKE WAY HOMES LOCATED ON THE LEFT General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Lot Size: Deck: Type of Work: ALT Fire Dist.: 5 No. of Stories: Occ. Load: Building: Valuation: Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: Model: Width: Ft. Rear: Ft. Slope: Ft. SEPA?: Side 1: Ft. Shoreline Desig.: Year: Serial No.: Side 2: Ft. Comp, Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type City. Type By Date Amount Receipt Additional Fixtures 1 Total BLD2015-01062 Please refer to the following pages for conditions of this permit. Page 1 of 4 CASE NOTES FOR BLD2015-01062 CONDITIONS FOR BLD2015-01062 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-�4,7-0_982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2) Owner-/ gent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X BLD2015-01062 Please refer to the following pages for conditions of this permit. Page 2 of 4 3r The installation of solar(thermal or photovoltaic) energy systems to provide space heating or cooling, hot water and swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code, the International Fire Code, and be shall be listed and labeled in accordance with UL1703. Roof mounted panels shall weigh no more than 3 Ibs/square foot and shall not exceed 1000 lbs. Supports for solar panels are to be installed to spread the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-Ibs are created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the inspection by the Mason County Building Inspector. Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings. Not less than two- 3-foot wide access pathways shall be provided from the eave to ridge. Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection. Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight, collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector. Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit. Solar energy collectors, controls, dampers, fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials, flashed and sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for inspection. X 4) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 44-- 5) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENTAND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspeogr hall be made prior to requesting additional inspections. X -f�f BLD2015-01062 Please refer to the following pages for conditions of this permit. Page 3 of 4 6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mas�unty ordinances and building regulations. X 7) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holds Have prevented action from being taken. No more than one extension may be granted. X OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PER IT APP ATIO'/N OF 80 DAYS WILL INVALIDATE THE APPLICATION. ` Si nMLW Date ► ou/ -ef OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) BLD2015-01062 Please refer to the following pages for conditions of this permit. Page 4 of 4 o CONCRETE MECHANICAL MANUFACTURED HOME D U, Footings ISetbacks GaDate s Piping By Ribbons o Inteinor Date By interior-Date €y Data By m rn Extefkx Date By Exterior-Date By _up r" Point Load i Isolated Footings ngs BG 1 SLAB INSULATION Date 8y G) D Date By Data By FIRE DEPARTMENT Foundation Walls Floors Date I31 Date 5y Data By DECKS F RAM I NG waits Date Ell Date 5y Data By PROPANE TANKS PLUMBING Vault C-Ato 8y owe ey OTHER Groundwork Ate Cate By Type- Bata B y Date 8y Da WV DRYWALL rypa- Int Brace Wall Dat- By 100 �.e?F By CD Date By m FINAL INSPECTION � Zn Water tine Fire SeparationCD G N C CD Cate By Hate By Date / Zz /` By l � CD s Pass or Request Inspect. c Type of Insp. Fail Date Date Dane By Comments o CD rn 1/u /G 11 Z ! :56L— N a v m i o i 0 0 Q 0 0 s N CD 3 t {pg� E N (D • Components Installed Per Manufacterers Specifications _ • Overall Roof Area: 3,849ft2 — �— • Overall Solar Area: 649ft2 • Solar Covers About 17 of Overall Roof Area • 18" Pathway Maintained Along Horizontal Ridges • Solar Array Does Not Exceed 18" Off Of Roof Deck • Total Dead Load of Modules & Racking: 2.441b/ft2 18" b 00 A � I SA N MM/DD/YY REVISION REMARKSMARKS 1 ' 1 12/23/2o16 q.gkW Solafforld Solar Amy O P1�Tbi��lDfi�hEad E L E C T R I C 2 / /-- ... 0 3 --/--/-- ... 1 Sofa t 4 --/__/-- ... -Components Installed Per Manufacturers Specifications -Dead Load of Solar: 2.591b/ft2 -Total Weight of Solar & Rails: 1,6811b -Total Area of Roof: 3933ft2 -Total Area of Solar: 649ft2 -Solar Covers 16.5% of Overall Roof Area -Solar Does Not Exceed 18" off of Roof Deck •18" Setback From Horizontal Ridges 7N,\ co 18 �� 00 REVISIONS Gary Maxwell • � � MM/DD/YY RE S O ELECTRIC 1 12/3/2oi6 q.gkW SolarWorld Solar Array N Allyn, WA 98524 - , , ..�,...�.� _ - 3 --/--/-- ... O Sola ^ �^ motion a __/--/__ ••• ARRAY SPECIFICATIONS 0 CONDUIT AND CONDUCTOR SCHEDULE TAG DESCRIPTION OF CONDUCTOR TYPE COND. NUMBER OF CONDUIT CONDUIT O Array Specifications Inverter#1(dc) Inverter#1(dc) GAUGE CONDUCTORS TYPE SIZE r 1 BARE(EGC) 8 AWG 1 Bare N/A N/A" O� 9.975 kW PV Imp 18.4 A PV Imp 18.4 A 2 PV WIRE/THHN THWN-2 10 AWG 2 R,2 B,1G(EGC/GEC)#8 EMT 1" L O 285W SolarWorld Modules PV Vmp 350 V PV Vmp 350 V 3 THHN THWN-2 8 AWG 1 B(Ll),1 R(1-2),1 W(NEUT),1 G(GRND)#10 EMT 3/4" sp W I fV 35 Modules PV Voc 500 V PV Voc 500 V 4 GROUNDING ELECTRODE COND 6 AWG Bare 1 CU N/A N/A (1)Strings of(23)in Series Source Circuit PV Isc 24.6 A PV Isc 24.6 A M E N (1)Strings of(13)in Series Source Circuit 1 String of 23 1 String of 13 L1a f0 T 0 Module Max Voltage Regulated �_� Ratings Design Temp AC Circuit By The SolarEdge System fG d e SW 285 Hot 29"C 240 V Nominal U N Ln �Vo 9.2 A Nom 25'C 42 A Max 9 aLi CA 9.84A Cold -17"C LINE 41 Cl-2 3 31.3 V TcVoc -.30%/"C ^^ W E - O c 39.7 V Max Voc 44.7 V 'V 1 >a—— — —— — — LOAD �Ln z A —43 w s Max Continous M dj e 0 r° W Output 42 A (6 « 10 3 i 2 SolarEdge 1000ow O 4J Inverter 200 d 3 N 6 Main C = W O' L ( J E ; C t x AC 8 Gl Lr) A ^� AC 22SA Bus 0 f N v, in l Disconnect LINE ui w G 2 ) ( DC ^A ^ 60 Amp a E 3 ) 1 V I Inverter OCPD a)v 0 ( — --- —OA— —) 141 15 A Fuses — inL Q of — +( i i m O 1 T l �— ---J ) p O z ) ) 1 1 ) Inverter Max Continuous W DC Disconect 7 ) Output 42 Amps Q N J I z --- -- t -- — -- — z -- —————————— ————————— —� z ) Production Meter 4 @$0.15/kWH i r W 41 4 ' cn OEQUIPMENT SCHEDULE N TAG EQUIPMENT LOCATION DESCRIPTION rft7 1 SOLAR PV MODULE South and East Roof of House 9.975kW System:35 SolarWorld 285 Mono;285W Each; SW285 Mono O O 2 DC OPTIMIZER Underneath Modules (35)SolarEdge 300 Power Optimizers;8-48VDC;MC4 Compatible;15A; SolarEdge P300(for 60Cell Modules) 3 PV ARRAY South and East Roof of House 35 Modules: (1)String of(23)Modules(1)String of(13)Modules on SolarEdge 10000 Inverter 4 DC DISCONNECT Bottom of Inverter Integrated in bottom of Inverter 5 INVERTER North Exterior Garage Wall (1)SolarEdge 10000 Inverter;SE10000A-US;(4)15 AMP DC Fuses; `; CO CO 6 AC DISCONNECT North Exterior Garage Wall AC Disconnect;VLB/Throwswitch C 7 PRODUCTION METER North Exterior Garage Wall 125_A Meter Colocated with Utility Meter _;� N 8 200 AMP MAIN SERVICE PANEL North Interior Garage Wall 240 VAC 200 AMP MAIN,225 AMP BUS,60 AMP OCPD MU 9 UTILITY METER North Exterior Garage Wall Mason County PUD Meter#23627 U FROM INVERTER In 1.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON '4 HOT HOT ASHRAE MINIMUM MEAN EXTREME DRY BULB 0 TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO \ INSTALLATION LOCATON.LOWEST EXPECTED AMBINET TEMP:-17°C � 0 L \ w W .4 N i1 2.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED E .. ON ASHRATE HIGHEST MONTH 2%DRY BULB m E TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO L. 0) INSTALLATION LOCATION.HIGHEST CONTINUOUS C Q TEMPERATURE:29°C M >` 3.)2005 ASHRAE FUNDEMENTALS 2%DESIGN �0 2 7 u ^' TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED 'L W STATES.FOR LESS THAN 9 CURRENT-CARRYING 0+ CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT AT d 3 LEAST 0.5"ABOVE ROOF AND USING THE OUTDOOR i DESIGN TEMPERATURE OF 47`C OR LESS(ALL OF UNITED LU O) 'Ei C > STATES) CT >Q ` 0 O O in A 3 c w a.)12AWG,90'C CONDUCTORS ARE GENERALLY C i' o ACCEPTABLE FOR MODULES WITH Isc OF 7.68AMPS OR (0 N 0 E W 0 LESS WHEN PROTECTED BY A 12AMP OR SMALLER FUSE. .0, w 3 IV r0L v c� UJ II b.)10AWG,90°C CONDUCTORS ARE GENERALLY J E Ln ACCEPTABLE FOR MODULES WITH Isc OF 9.6AMPS OR LESS C Ln '� y WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. O N N U1 TO SERVICE PANEL ui w Q INTERCONNECTION HOT HOT m a w BREAKER 22 in in vi U z0 m N 00 240 VAC r `D UJI a Ln For Details on the SolarEdge System Please Visit: aNz www.solaredge.us/groups/support/downloads Specific WhitePaper: SolarEdge System Design and the National Electrical Code Photovoltaic Power Source Photovoltaic Power Source w v RATED MPP CURRENT 18.14 A RATED MPP CURRENT 18.14 A PV MODULE RATINGS @ STC 1 V) RATED MPP VOLTAGE 350 V RATED MPP VOLTAGE 3SO V MAX SYSTEM VOLTAGE S00 V MAX SYSTEM VOLTAGE 500 V MODULE MAKE SolarWorld MAX CIRCUIT CURRENT 24.6A MAX CIRCUIT CURRENT 24.6 A MODULE MODEL SW 280 mono a) WARNING;ELECTRICAL SHOCK WARNING;ELECTRICAL SHOCK Y In fu ZN T RATINGS HAZARD-LINE AND LOAD MAY BE HAZARD-LINE AND LOAD MAY BE INVERTERMAX POWER-POINT CURRENT(Impp) 9.2 A Ln E ENERGIZED IN OPEN POSITION ENERGIZED IN OPEN POSITION INVERTER MAKE SolarEdge MAX POWER-POINT VOLTAGE(Vmpp) 31.3V T � SOLAR PV SYSTEM AC DISCONNECT SOLAR PV SYSTEM AC DISCONNECT IY (— POINT OF CONNECTION POINT OF CONNECTION INVERTER MODEL I SolarEdge 10000;SE10000A-US OPEN CIRCUIT VOLTAGE(Voc) 39.7V MAX DC VOLT RATING 600 V SHORT-CIRCUIT CURRENT(Isc) 9.71A A T > AC OUTPUT CURRENT 42A AC OUTPUT CURRENT 42A ► ► 67 c0 Do NOMINAL AC VOLTAGE 240 V NOMINOL AC VOLTAGE 240 V MAX POWER @ 29°C 10000W MAX SERIES FUSE(OCPD) 15A ^� C _0 THIS PANEL FED BY MULTIPLE THIS PANEL FED BY MULTIPLE NOMINAL AC VOLTAGE 240V MAXIMUM POWER(Pmax) 280W `w (L0 v SOURCES(UTILITY AND SOLAR) SOURCES(UTILITY AND SOLAR) MAX AC CURRENT 42A MAX VOLTAGE(TYP 60OVDC 600V 0 U MAX OCPD RATING 60A VOCTEMP COEFFICIENT(mV/°C or%/^C®) -.30 Sunmodule;/ Plus SOLARWORLD SW285 MONOREALVALUE 3�,M.tu V'c% � ..., ' TUV Power controlled: 3 TUVHh.W..d Lowest measuring tolerance in industry 'O 000002b,'t1 Every component is tested to meet 3 times IEC requirements J Designed to withstand heavy accumulations of snow and ice Sunmodule Plus: Positive performance E J P I 25-year linear performance warranty and 10-year product warranty J FLA Glass with anti-reflective coating IM10 World-class quality SMKV ,!E,61I15 a 4mmo Salarynia.wiamMa V • turoE,IEC 81 T]0 Fully-automated production lines and seamless monitoring of the process and mate- rial ensure the quality that the company sets as its benchmark for its sites worldwide. �aoa SolarWorld Plus-Sorting 'ENFORM-N S ED C Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules ^°�DLT^�°^°°� eUs that have greater than or equal to the nameplate rated power. UL 1703 DVE 25-year linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course ` a G of 25 years, a significant added value compared to the two-phase warranties com- mon in the industry.In addition,SolarWorld isoffering a product warranty,which has been extended to 10 years.' Homelnnovation NGRS GREEN CERTIFIED. 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty solarworld.com IMPORTED PARTS Sunmodule ✓ Plus . . " SW285 MONO REALVALUE PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' PERFORMANCE AT 800 W/mz,NOCT,AM 1.5 Maximum power P,,,,,, 285 Wp Maximum power P" 213.1 Wp Open circuit voltage V. 39.7 V Open circuit voltage V. 36.4 V Maximum power point voltage Vmpp 31.3 V Maximum power point voltage Vmpp 28.7 V Short circuit current I,� 9.84 A Short circuit current Ix 7.96 A Maximum power point current Impp 9.20 A Maximum power point current I,"pp 7.43 A Module efficiency Om 17.0% Minor reduction in efficiency under partial load conditions at 25'C:at 200 W/m2,100% (+/-2%)of the STC efficiency(1000 W/m2)is achieved. 'STC:1000 W/m=25'C,AM 1.5 1)Measuring tolerance(P_)traceable to TUV Rheinland: 2%(TUV Power Controlled). COMPONENT MATERIALS THERMAL CHARACTERISTICS Cells per module 60 NOCT 46'C Cell type - Mono crystalline TC 1, 0.04%/'C Cell dimensions 6.17 in x 6.17 in(156.75 x 156.75 mm) TCv. -0.30%/'C Front Tempered glass(EN 12150) -Tic Pmpp -0.41%/'C Frame Clear anodized aluminum Operating temperature -40'C to 85'C Weight 39.5 Ibs(17.9 kg)- SYSTEM INTEGRATION PARAMETERS 1000 W/m= Maximum system voltage SC 11/NEC 1000 V - - Maximum reverse current 25 A 800 W/m� - Number of bypass diodes - 3 g 600 W/mz Design Loads' Two rail system 113 psf downward64 psf upward I `- E 170 psf downward Y400 W m= Design Loads' Three rail system n psf upward f -- --- -- - -- Design Loads' Edge mounting 30 psf downward 200 W/W 30 psf upward 100 W/m� Please refer to the Sunmodule installation instructions for the details associated with these load cases. Module voltapM V« ADDITIONAL DATA Powersorting' -0 Wp/+5 Wp --x 4 37.44(951) J-Box IP65 Moduleleads PV wire per UL4703 with H4 connectors Module type(UL 1703) 1 11.33(288) Glass Low iron tempered with ARC 39.37(1000) 0.6 15.3 VERSION 2.S FRAME Version Compatible with both"Top-Down" 25frame and"Bottom"mounting methods 65.94(1675) bottom ♦Grounding Locations: mounting 4 corners of the frame y holes 4locations along the length of the L module in the extended flanget 6 x4 4.20 007)t 1.22(31) 39.41(1001) �i All units provided are imperial.SI units provided in parentheses. Solar World AG reserves the right to make specification changes without notice. SW-01-6007US 12-2014 s o l a r - • %ei- SolarEdge Single Phase Inverters For North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US e r ter 12_25 wartao�Y; ,. Jal,anJ`. 9 The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance -- Superior efficiency(98%) Small, lightweight and easy to install on provided bracket Built-in module-level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional—revenue grade data, ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us Single Phase Inverters for North America solar.=ee SE3000A-US i SE380OA-US/SE5000A-US/ SE6000A-US/ SE760OA-US/SE10000A-US/SE1140OA-US - SE3000A-US SE3800A-US SEM00A US SE6000A US SE7600A US SE10000A-US SE11400A US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA .............. ............... . ............... ................ ................ .10000 9240V Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA ...... .......... ............I... ............... .5450 240V �°....... l.ag.Min...... ✓....... ................ ................ 10950 240V .................. ........... AC Output Voltage Min:Nom.-Max.ltl ✓ 183-208-229 Vac " ....................................I...... ................ ............... ................. ................ ................ .................. .................. ........... AC Output Voltage Min:Nom:Max.1i1 ✓ ✓ ✓ ✓ 211-240-264 Vac ........................................... ................ ............... ................. ................ ................ .................. .................. ... .. A Frequency Min.-Nom.Max.iti 59.3-60-60.5(with HI country setting 57-60-60.5) Hz 24 @ 208V 48 @ 208V .............. f Max.Continuous Output Current 12.5 16 ( 25GFDI I.......32...,...f_._42.@240V 47.5. A 21.@.240V.. ................l ........................................... ................................... ......... A . . Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes........ ................................................... ...Yes.... INPUT Recommended Max.DC Powerizj 3750 4750 6250 7500 9500 12400 14250 W JSTD).................................... ................ ...............I................. ..........._.... ................ .................. .................. ........... Transformer-less,Ungrounded Yes M .............. .......................................................................................................................... ........... ax.Input Voltage 500 Vdc ............................................ ........... Nom.DC In . ......... .put Voltage 325 @ 208V/350 @ 240V Vdc 5 @ 208V 33 @ 208V Max.Input Current•il 9.5 13 16. 18 23 34.5 Adc 15 S.�a 240V 30.5 @ 240V ........... f:::::::::::::::::: Max.Input Short Circuit Current 45....................................... ..................... Reverse-Polari Protection ........................................ ................................ ...........................Yes............................................................... ........... Ground-Fault Isolation Detection 600kc Sensitivity .................................... ................ ............... ................ .................. .................. ........... Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 % ..............I....................... ................ .. ................ ...........I...... .................I ........... ................. ................ 97.5 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 % ..........g. 98 @1240V Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,Zi Bee Revenue Grade Data,ANSI C12.1...... Optional.................... (41 ............................................... . ......... ..................................... ................................................. ......... ....................................... ........... Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid..shutdown..kit is installedl5j STANDARD COMPLIANCE Safety UL1741,UL16998,UL3998,CSA 22.2 ................... .......................................................................................................................... ........... Grid Connection Standards IEEE1547 Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size./ range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG .......................................... ........... ........... DC input conduit size/#of strings/ 3/4"minif-m y 1-2-strings/16-6 AWE AWG ran e - -3f 4"mimmum/1-2 strings/14 6 AWG - .........&s with ........................ ................................['., .......... ..................... ................................... ....... .Dimensions with Safety Switch 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ 30.5 x 12.5 x 10.5/775 x 315 x 260In/HxWxD ... 775x315x172 775x315x191 ... mm We.. t with Sa ety Switch ..__ ...I.51.2/23.2 .......54.7/24.7 .................. ..88.4/40.1 Ib/kg........ Cooling ................................ ...... ,_....Natural Convection Fans.(user.reP laceable. . ) .... ..... .. ...... . ................ ........... Noise <25 <50 dBA ................................ ................................................................. .......I.... Min.-Max.Operating Temperature ..Rang?. 13 to+140 J-25 to+60(-40 to+60 version avaliable(')) F/.C ...... .... . .. .. . .... .... ..... .. . .. ... ...... .. . .. ................................................................ ........... Protection Rating....................... .............................. NEMA 3R............. ..............................,........Ir1 For other regional settings please contact SolarEdge support. ........... 2 Limited to 125%for locations where the yearly average high temperature is above 77'F/25'C and to 135%for locations where it is below 77'F/25'C. For detailed information,refer to http.,/=zze.uslfiles/pdfs/imerter zze.us/files/odfs/imerter do oversizing euide odf isl A higher current source may be used;the inverter will limit its input current to the values stated. 141 Revenue grade inverter P/N:SExxxxA-US000NNR2 Isi Rapid shutdown kit P/N:SE1000-RSD-Si 161-40 version P/N:SExwcxA-US000NNU4 SUf15PEC RoHS soiatEdge Technologies.Inc.All rights reserved.SOLAREDGE,the SolarEdge logo.OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks are trademarks of their respective owners.o•_ • • •� Subject to change without notice. • Components Installed Per Manufacterers Specifications • Overall Roof Area: 3,849ft2 = • Overall Solar Area: 649ft2 • Solar Covers About 17% of Overall Roof Area • 18" Pathway Maintained Along Horizontal Ridges • Solar Array Does Not Exceed 18" Off Of Roof Deck • Total Dead Load of Modules & Racking: 2.44lb/ft2 18„ ono 0o L-2 ,$�vw '�I� ' IJ'�N MM/DD/YY REVISION�S��Pl�tBi��ZMhFadE LE C"T F2 I C 1 12/23/2oi6 q.9kW SolarWorld Solar Array O 2 --/--/-- ... p 3 --/--/-- ... Ma tion 4 _ -Components Installed Per Manufacturers Specifications -Dead Load of Solar: 2.59lb/ft2 -Total Weight of Solar & Rails: 1,6811b -Total Area of Roof: 3933ft2 -Total Area of Solar: 649ft2 -Solar Covers 16.5% of Overall Roof Area -Solar Does Not Exceed 18" off of Roof Deck •18" Setback From Horizontal Ridges ao 18 " 00 xEvzsiox Gary Maxwell v ARTISAUN MM/DD/YY REMARKS Q! E LE C T' R I C: 12/3/2oi6 q.gkW SolarWorld Solar Array O Allyn, WA 98524 3 Sola tion a __/__/__ ... `p ARRAY SPECIFICATIONS 0 CONDUIT AND CONDUCTOR SCHEDULE TAG DESCRIPTION OF CONDUCTOR TYPE COND. NUMBER OF CONDUIT CONDUIT O Array Specifications Inverter H 1(dc) Inverter#1(dc) GAUGE CONDUCTORS TYPE SIZE N 1 BARE(EGC) 8 AWG 1 Bare N/A N/A" ON 9.975 kW PV Imp 18.4 A PV Imp 18.4 A 2 PV WIRE/THHN THWN-2 10 AWG 2 R,2 B,1G(EGC/GEC)#8 EMT 1" L. > 0 285W SolarWorld Modules PV Vmp 350 V PV Vmp 3504A ' 3 THHN THWN-2 8 AWG 1 B(Ll),1 R(L2),1 W(NEUT),1 G(GRND)#10 EMT 3/4" w Ni 35 Modules PV Voc 500 V PV Voc 500 4 GROUNDING ELECTRODE COND 6 AWG Bare 1 CU N/A N/A (1)Strings of(23)in Series Source Circuit PV Isc 24.6 A PV Isc 24.6 E Qj (1)Strings of(13)in Series Source Circuit 1 String of 23 1 String of 13 L. O 'J OIL Module Max Voltage Regulated Ln Design Temp AC Circuit > a Ratings By The SolarEdge System u a N SW 285 Hot 29"C 240 V Nominal N Imp F Nom 25"C 42 A Max 9 �L± V) 00 Isc Cold -17"C V LINE N d 3 Vmp TCVoc -.30%/'C W c Voc Max Voc 44.7 V M 01 QtV a5. I LOAD fp — > a i — — -- — -- — — �Ln `-' ; m` (D i Max Continous v c LU 1 s M y Q 0 p Output 42 A ++ (o p m 1 2 I SolarEdge 10000W t j 0 y I 1 inverter 200 C a 3 N 1 I 6 Main — w t 8 J E ;N cn r — — — ---- — I O ytn q .a AC 225A Bus O N AC N 2 I Disconnect LINE 6 v U I Ea a DC1^A ^ 60 Amp �o� E 3 I I V I Inverter OCPD v N 1 (4)15 A Fuses — ——— —CIA — — — iT)Lr) U) Q i+ 1 z 1 — I 1 m 0 —T� --� 2 1 1 1 1 I Inverter Max Continuous LD 1 I DC Disconect I Output 42 Amps Q Lr) J � I � ---- -- � -- — -- — 2 I 4 1 1 z I z I Production Meter 4 @$0.15/kWH 1 ' LU cU OEQUIPMENT SCHEDULE O) TAG EQUIPMENT LOCATION DESCRIPTION 1 SOLAR PV MODULE South and East Roof of House 9.975kW System:35 SolarWorld 285 Mono;285W Each; SW285 Mono O O 2 DC OPTIMIZER Underneath Modules (35)SolarEdge 300 Power Optimizers;8-48VDC;MC4 Compatible;15A; SolarEdge P300(for 60Cell Modules) 3 PV ARRAY South and East Roof of House 35 Modules: (1)String of(23)Modules(1)String of(13)Modules on SolarEdge 10000 Inverter 4 DC DISCONNECT Bottom of Inverter Integrated in bottom of Inverter . A 15 5 INVERTER North Exterior Garage Wall (1)SolarEdge 10000 Inverter;SE10000A-US;(4) AMP DC Fuses; `,� CD m 6 AC DISCONNECT North Exterior Garage Wall AC Disconnect;VLB/Throwswitch 7 PRODUCTION METER North Exterior Garage Wall 125_A Meter Colocated with Utility Meter 8 200 AMP MAIN SERVICE PANEL North Interior Garage Wall 240 VAC 200 AMP MAIN,225 AMP BUS,60 AMP OCPD V 9 UTILITY METER North Exterior Garage Wall Mason County PUD Meter#23627 U FROM INVERTER 1.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON "a HOT HOT ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO \ INSTALLATION LOCATON.LOWEST EXPECTED AMBINET 011 TEMP:-17'C 0 Lij N w � 2.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED £ ON ASHRATE HIGHEST MONTH 2%DRY BULB M E 0) TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO L. 0) INSTALLATION LOCATION.HIGHEST CONTINUOUS I l4/ TEMPERATURE:29°C >` �Lr) a 3.)2005 ASHRAE FUNDEMENTALS 2%DESIGN V a N TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED 'L Q) 00 0 STATES.FOR LESS THAN 9 CURRENT-CARRYING fp CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT AT d 3 LEAST 0.5"ABOVE ROOF AND USING THE OUTDOOR i DESIGN TEMPERATURE OF 47°C OR LESS(ALL OF UNITED LU WE j. > STATES) CT < M. O O O MC 1° > < zN m 3 m a.)12AWG,90°C CONDUCTORS ARE GENERALLY C t 0 O LL) ACCEPTABLE FOR MODULES WITH Isc OF 7.69AMPS OR M v 0 Y LESS WHEN PROTECTED BY A 12AMP OR SMALLER FUSE. U 0 d r a+ In 0) C= N W o!C, CA � II b.)10AWG,90-C CONDUCTORS ARE GENERALLY I E x ul ACCEPTABLE FOR MODULES WITH Isc OF 9.6AMPS OR LESS Ln x "� y WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. C N to N TO SERVICE PANEL E V) a INTERCONNECTION HOT HOT z Q E BREAKER Y Y � in in In O C� zo cO N Oo 240 VAC `o Q � Ln F- For Details on the SolarEdge System Please Visit: z www.solaredge.us/groups/support/downloads Specific WhitePaper: SolarEdge System Design and the National Electrical Code Photovoltaic Power Source Photovoltaic Power Source W v N RATED MPP CURRENT 18.14 A RATED MPP CURRENT 18.14 A PV MODULE RATINGS @ STC In RATED MPP VOLTAGE 350 V RATED MPP VOLTAGE 350 V MAX SYSTEM VOLTAGE 500 V MAX SYSTEM VOLTAGE S00 V MODULE MAKE SolarWorld MAX CIRCUIT CURRENT 24.6A MAX CIRCUIT CURRENT 1 24.6 A N WARNING;ELECTRICAL SHOCK WARNING;ELECTRICAL SHOCK MODULE MODEL SW 280 mono Y (n HAZARD-LINE AND LOAD MAY BE HAZARD-LINE AND LOAD MAY BE INVERTER RATINGS MAX POWER-POINT CURRENT(Impp) 9.2 A Ln E ENERGIZED IN OPEN POSITION I ENERGIZED IN OPEN POSITION INVERTER MAKE SolarEdge MAX POWER-POINT VOLTAGE(Vmpp) 31.3V 0 0 SOLAR PV SYSTEM AC DISCONNECT SOLAR PV SYSTEM AC DISCONNECT CL ♦— POINT OF CONNECTION POINT OF CONNECTION INVERTER MODEL I S01arEdge 10000;SE10000A-US OPEN CIRCUIT VOLTAGE(Voc) 39.7V AC OUTPUT CURRENT 42 A AC OUTPUT CURRENT 42A MAX DC VOLT RATING 600 V SHORT-CIRCUIT CURRENT(Isc) 9.71A > > T 6 CO m NOMINOL AC VOLTAGE 240 V NOMINOL AC VOLTAGE 240 V MAX POWER @ 29-C 10000W MAX SERIES FUSE(OCPD) 15A c p THIS PANEL FED BY MULTIPLE THIS PANEL FED BY MULTIPLE NOMINAL AC VOLTAGE 240V MAXIMUM POWER(Pmax) 28OW `i�►. v SOURCES(UTILITY AND SOLAR) SOURCES(UTILITY AND SOLAR) MAX AC CURRENT 42A MAX VOLTAGE(TYP 600VDC 600V U MAX OCPD RATING WA VOC TEMP COEFFICIENT(mV/°C or%/°C®) -30 Sunmodule/ Plus SOLARWORLD SW285 MONO REALVALLIE tuv TUV Power controlled: ruvan.piR-a Z Lowest measuring tolerance in industry 00000,1 P111Every component is tested to meet 3 times IEC requirements J LkDesigned to withstand heavy accumulations of snow and ice A Sunmodule Plus: ®� Positive performance tolerance LI ' `ar 25-year linear performance warranty �f and 10-year product warranty J FEAR Glass with anti-reflective coating iffliJ World-class quality o 11111 Nv�n.a,'EC • a .emn,"m,ml.e•nc. v �1�.iEc s,r" e»aa Fully-automated production lines and seamless monitoring of the process and mate- p e P.,,�,cfp per.. <.....a.e •81ow1,g R.M rv.isbnl � rial ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting \P TMlM RES AS CC A® $AIT MIST flE515iANi Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules J °� T^��ppp� C us that have greater than or equal to the nameplate rated power. UL 1703 EVE • 1 1° 25-year linear performance guarantee and extension of product warranty to 10 years C I 1 SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course ` i_ G of 25 years, a significant added value compared to the two-phase warranties com- mon in the industry.In addition,SolarWorld is offering a product warranty,which has pp been extended to 10 years.* Home Innovation NGBS GREEN CERT;iIEp- 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty solarworld.com AND DIMPORTED Sunmodule;,-/ Plus . SW 285 MONO PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' PERFORMANCE AT 800 W/M2,NOCT,AM 1.5 Maximum power Pam. 285 Wp Maximum power Pm„ 213.1 Wp Open circuit voltage V_ 39.7 V Open circuit voltage V. 36.4 V Maximum power point voltage Vmw 31.3 V Maximum power point voltage Vmpp 28.7 V Short circuit current Ix 9.84A Short circuit current Ix 7.96A Maximum power point current Impp 9.20 A Maximum power point current Impp 7.43 A Module efficiency nm 17.0% Minor reduction in efficiency under partial load conditions at 25'C:at 200 W/m;100% (+/-2%)of the STC efficiency(1000 W/m=)is achieved. 'STC:1000 W/m2,25•C.AM 1.5 1)Measuring tolerance(P)traceabletoTUVRheinland:+/-2%(TUVPowerControlled). COMPONENT MATERIALS THERMAL CHARACTERISTICS Cells per module 60 NOCT 46'C Cell type Mono crystalline TC 1x 0.04%/'C Cell dimensions 6.17 in x 637 in(156.75 x 156.75 mm) TCv= -0.30%/'C Front Tempered glass(EN 12150) TCPmpp -0A1%/'C Frame Clear anodized aluminum Operating temperature -40'Cto85'C Weight 39.5 Ibs(17.9 kg)- --------- SYSTEM INTEGRATION PARAMETERS IX 1000 W/m= Maximum system voltage SC 11/NEC 1000 V Maximum reverse current 25 A 800 W/m2 Number of bypass diodes 3 600 W/m2 Design Loads' Two rail system 113 psf downward 64 psf upward = Design Loads' Three roil system 170 psf downward 400 W/m 71 psf upward Design Loads* Edge mounting 30 psf downward 200 W/rrP 30 psf upward 100 W/ms *Please refer to the Sunmodule installation instructions for the details associated with these load cases. Module voltage[VI V� ADDITIONAL DATA Power sorting' -0 W p/+5 W p -L-x 4 37.44(951) J-Box I P65 — Module leads PV wire per UL4703 with H4 connectors Module type(UL 1703) - -_ _ --— 1 -- 11.33(288) Glass Low iron tempered with ARC 39.37(1000) 0.605.3) VERSION 2.5 FRAME Version Compatible with both"Top-Down" 2.5frame and"Bottom"mounting methods 65.94(1675) bottom N ♦Grounding Locations: mounting 4 corners of the frame u v holes 4 locations along the length of the module in the extended flanget 7.34(34) 20(107)t 1.22(31) 4�39.41(1001) �I All units provided are imperial.Sl units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. SW-01-6007US 12-2014 solar - • • SolarEdge Single Phase Inverters For North America SE3000A-US / SE38OOA-US / SE5000A-US / SE6O0OA-US / SE760OA-US / SE1O00OA-US / SE1140OA-US d , r �werte, . 12 waiia t'1; The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance Superior efficiency(98%) Small, lightweight and easy to install on provided bracket Built-in module-level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us solar=eeSingle Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US SE760OA-US/SE10000A-US/SE1140OA-US — - SE3000A-US SE3800A-US SESOOOA-US SE6000A-US SE760OA-US SE1000OA-US SE114_0OA_-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ........................................... ..............I. 10000 @ 240V Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA s4so@240 . ................ ................ .10950.@240V..............I ............... . ...... . . .................. ........... AC Output Voltage Min.-Nom:Max.ltl ✓ 183-208-229 Vac ....................I............. ................ ............... ................. ................ ................ .................. .................. ........... AC Output Voltage Min.-Nom.-Max.itl ✓ ✓ ✓ 211-240-264 Vac ........................................... ................ ............... ................. ................ ................ .................. .................. ........... AC Frequency Min:Nom.-Ma..l.. 59.3-60-60.5(with HI country setting 57-60-60.5) Hz 24 @ 208V 48 @ 208V Max.Continuous Output Current 12.5 16 25 32 47.5 A ..... ............... 21.@.240V.. ................�................1...42.@ 240V...I.................. ........... GFDI1............................... .......................................................................................................................... ......A ..... Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT Recommended Max.DC Powe0l) 3750 4750 6250 7500 9500 12400 14250 W ..(STC).....................I...I.......... ................I............... .................I................ .......I........ .................. .................. ........... Transformer-less,Ungrounded Yes ........................................... .......................................................................................................................... ........... Max.Input Voltage Soo Vdc . .................... .......................................................................................................................... ........... Nom.DC Input Voltage ............... ............. 325 @ 208V/350 @ 240V Vdc 16.5 @ 208V 33 @ 208V ........ ... Max.InputCurrenT3j 95 .............13 18 23 34.5 Adc ...... . 15.5 240V 30;5.@ 240V.. ...Adc Max.Input Short Circuit Current 45 Reverse-Polarity Protection Yes ........................... ............ ....................................... ............................................................... ........... Ground-Fault Isolation Detection 600ko Sensitivity ....................................... ................ ............... ................. ................ ................ .................. .................. ........... Maximum Inverter Efficiency......... 97.7 98.2 983 98.3 98 98 98 9. 97.5 @ 208V ( 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 9..5 % ........................................ ................ ............... ...98 @.240V.. ................ ................ ..97;5.@ 240V . . . .. .................. ........... Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) Revenue Grade Data,ANSI C12.1 141 ..............I...........I................ Optional Rapid Shutdown—NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed(51 STANDARD COMPLIANCE Safety UL1741,UL1699B,UL1998,CSA 22.2 . ......................................... .......................................................................................................................... ........... Grid Connection Standards IEEE1547 .................................. ............................................. .................................................I................. ........... Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG UCrpfr3 conduit size J#of strirsgs t AWG ran a 3/4"minimum/1-2 strings/16-6 AWG 3/4"minimum/1-2 strings/14-6 AWG .......... K .............................1................................ .................................. ............. Dimensions with Safety Switch 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ in/ 30.5x12.5x10.5/775x315x260 (FIXWxP)................................ ........775 x 315_x 17......... ........775,x.315 x 191........ ...................................................... ...mm.... Weight with Safety Switch............. ..........51.2/23.?.......... ...........54.7/24:�........... .....................98.4�40:1..................... . lb/.kg.. Cooling Natural Convection Fans(user.replaceable) ............. ... ................... ........... Noise <25 <50........................ ...dBA. .... ........................................... ................................................................. . .............................. . .. Min.-Max.Operating Temperature Ran a -13 to+140/-25 to+60(-40 to+60 version available ) 'F/°C ......g.................................... ..................................................... ..................................................................... ........... Protection Rating NEMA 3R ......................................................................................................................... ........... W For other regional settings please contact SolarEdge support. 1�1 Limited to 125%for locations where the yearly average high temperature is above 77'F/25'C and to 135%for locations where it is below 77'F/25'C. For detailed information,refer to http://wv4w.wlaredae.us/files/`pdfs/imerter do oversizing guide pdf A higher current source may be used;the inverter will limit its input current to the values stated. i0I Revenue grade inverter P/N:SExxxxA-USOOONNR2 Rapid shutdown kit P/N:SE1000-RSD-51 iel-40 version P/N:SExxxxA-Us000NNU4 sunsae� R oHS Q SolarEdge Technologies.Inc.Ail rignts reserved.SOLAREDGE,the SolarEdge logo.OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed in this Checklist. All project plans and supporting documentation must be provided on site for the inspector. --------TO BE COMPLETED BY APPLICANT------- © Project Information Property Owner Name: 6.,r Project Address: ' gyp L��S�-hKG ,Jay Parcel# 12.2. 1 q,$000O.2 City- State 0 A- ZIP: 'T S 2 Day Phone: 1210 6 — Contractor Name ,��"sa h E'c ✓i C Lin C Contractor License#: f} T T S r- 9 7� ,DN Contractor day phone: ZEj6 5S7-�!Z j $— Describe project: Conventional framed built dwelling or garage, PV 0-�- h o h1e Pole structure,steel building, etc. Note: Manufactured/mobile homes require L&I Approval PV system description A Sim I t ( -7>S) UIarW o Zg r Mvh o 2 6 (include manufacturer W,cod u 1-4S ocV, 6 0, d o o lJ So 10 r EJ 5 e SC)o600Pt-iIS and model#of PV modules and h Ver+� inverters): ©Determine if your project qualifies for expedited permitting: Yes No 1. PV system is designed and proposed for a detached one-or two-family dwelling or townhouse not more than three stories above grade or detached accessory structure that �p ❑ is code compliant to setbacks and height,or code allows expansion of nonconformity for Y solar modules. [IRC 101.2] 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by �(,` ❑ the local jurisdiction. 3. Rooftop is made from lightweight material such as a single layer of composition shingles, ❑ metal roofing, lightweight masonry,or cedar shingles. 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.2] ❑ 5. The installation shall meet the requirements of NFPA 70 National Electric Code, and all required electrical permit(s) must be obtained from the Authority Having Jurisdiction to ❑ administer the electrical code. [IRC M2302.2] 6. The installation shall meet the requirements of the International Fire Code as amended ❑ by WA State. [IRC M2302.2] 7. The PV system is designed for the wind speed of the local area, and will be installed per ❑ the manufacturer's specifications. [IRC M2302.2.1(1)1 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] ( ❑ 9. Total dead load of modules, supports, mountings, raceways and all other appurtenances ❑ weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] t Enter total dead load of system (lbs/ft2): Click here to enter text. 10. To address uplift, modules are mounted no higher than 18" above the surface of the ❑ roofing to which they are affixed. [IRC M2302.2.1(4)] 11. Supports for solar modules are installed to spread the dead load across as many roof- framing members as needed to ensure that no point load exceeds fifty (50) pounds. C ❑ [IRC M2302.2.1(5)] 12. The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for &r, ❑ the roof construction. [IRC M2302.2.1] 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, ❑ rodents, and insects. [IRC M2302.2.2] 14. PV modules are listed and labeled with a fire classification in accordance with UL 1703. ❑ [IRC M2302.2.3] Comments: I Click here to enter text. If you answered yes to all of the above questions, the project qualifies for the over-the- counter permitting process. © Submit this Checklist, Site Plan, and other required permit application forms to: [insert contact info for jurisdiction having authority] yAs the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: Date: '116��(/'Z� /2 2 3 S Applicant Name (Please Print): df Wa/ --------TO BE COMPLETED BY MASON COUNTY STAFF------ Qualifies for OTC Building Permit? Yes ❑No Permit Application#: Staff Initia s ff6 i Date: Is 2 MASON COUNTY PERMIT NO. DEPARTMENT OF COMMUNITY DEN51-0136MENT BUILDING•PLANNING•FIRE MARSHAL _ WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360) 275-4467 Belfair ext. 352 Shelton,WA 98584 (360)482-5269 Elma ext. 352 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: Cray' A W e t I NAME' :rv► C. MAILING AD RESS: 1 'SD E7- WrStIaK-e— Wa.c MAILING ADDRESS: q q S.Nth rns K4 S� CITY: Ia-0 ri STATE: WIt ZIP: I zy CITY: 5rg*' J(f STATE: Lw ZIP: oa' PHONE:Sob ?R 3^ 9S'gCELL: PHONE: 'Zo&-S'S7-yz►S- CELL: 2-06 - 9 7 y -9 d'3 EMAIL:�o rhQx I (95— Wawc.CAb c. , rcr ,, , EMAIL : at JKezy @a,rf:Lao,[/rcfr;c,'h C , e-dr)'? L&I REG# ART-TSal- 136L I- EXP.c96 /2y/17 PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER): 122 I S o 0 o D z y LEGAL DESCRIPTION(ABBREVLtTED): SITE ADDRESS: 1 S-O F, I�lacr CITY: /�- IIV14 DIRECTIONS TO SITE ADDRESS: Freo, Ilw ke-J t.J es-I C- L-k ak I)r �'— c ''i F i/-'c s E I k �<c &tt a�h , Ham (cc' o-h TYPE OF JOB NEW ADD ALT REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS— 1sT FLOOR 2ND FLO R BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPG Natural Gas Ductless_ Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hose bibs Dryer Vent Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS P ERM:;;7CATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Signature of Applicant f Date X O Ce.,� G Owner/Owners Representative/Contractor Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL