HomeMy WebLinkAboutFIR2009-00022 - FIR Permit / Conditions - 5/12/2009 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton,WA 98584 FIRE PROTECTION PERMIT FIR2009-00022 APPLICANT: KEN & PEGGY CHOW RECEIVED: 4/22/2009 CONTRACTOR: AMERICAN PLUMBING CONSTRUCTION INC 1.360.791.6300 LICENSE: A ISSUED: 5/12/2009 SITE ADDRESS: 260 E UNION HEIGHTS DR SHELTON EXPIRES: 11/12/2009 PARCEL NUMBER: 322327590151 LEGAL DESCRIPTION: TR 15-A OF SURV 5/59 SEE SURVEY 6/126 TR 1 OF SP#2196 PROJECT DESCRIPTION: Fire Sprinkler System GENOUL INFORMATION System Information Type of Use: RES Fire District: 6 Sprinkler Heads: Audible Switches: Pull Stations: Hood&Duct t: Flow Switches: Visual Devices: Door Releases: Dry Chemical?: Pressure Switches:: Smoke Detectors: Duct Detectors: Wet Chemical?: Zones: Heat Detectors: Sprinkle(?: Y Standpipe?: Y SQUARE FOOTAGE FEES Monitoring Company: First Floor: Type Amount Due Amount Paid Monitoring Phone No.:()- Second Floor: Auto Fire Alarm?: Third Floor;: Sprinkler System Permit $277.70 $277.70 Sprinkler System Plan $138.35 $138.35 Total: $416.05 $416.05 FIR2009-00022 Please refer to the follo:ring pages for conditions of this permit. 1 of 4 CASE NOTES FIR2009-00022 i CONDITIONS FOR FIR2009-00022 1.) Per section 901.2.1 of the 2006 International Fire code, Statement of Compliance. Before requesting final approval of the installation, the installing contractor shall furnish a written statement to the fire code official that the subject fire protection system has been installed in accordance with the approved plans and has been tested in accordance with the manufactures specifications and the appropriat installation standard. Any deviations from the design standards shall be noted and copies of the approvals for such deviations shall be at t e written statement. X This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The ownerorthe agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure review and i spection. OWNER OR AGENT: �, DATE: FIR2009-00022 Please refer to the following pages for conditions of this permit. 2 of 4 J -n n CONCRETE MECHANICAL MANUFACTURED HOME _ 0 Date By p Footings J Setbacks Ribbons Gas Piping GInterior Date By Interior-Date By Date By m OC Exterior Date By Exterior-Date _ B Set-up Z N Point Load!Isolated Footings INSULATION nate By BG!SLAB INSULATION Date By Data By FIRE DEPARTMENT m Foundation Wails Floors Date By 0 G) Date By Data By DECKS FRAMING Walls Date By Date By Data By PROPANE TANKS PLUMBING Vault Date By Date By OTHER Groundwork Attic Type. Date By Date By Date By D.w.v DRYWALL Type: Int.Brace Wall Date By Date By Daie By N Water Lane FINAL INSPECTION 0 Fir®Se ration c� p Date By Date By Date ld Q / By ` C 0 Pass or Request Inspect. ` o Type of Insp. Fail Date Date Done By Comments----------------- N o / � '7�=w ce-A _C C�P� 4v-" 2 Aem:7 > 0 N H 3 w 0 h COVI n D W. MASON Id COUNTY SFIRE MARSHAL PO BOX 186 Shelton,WA 98584 U �/'�l� 1�ft=X,1& (360)427-9670 Ext.273 /�{ -, �(J" �j�'�`� Permit #-L e-- W 1 - ()) Mason County Fire Protection System Permit Application Incomplete application will not be accented Owner: IV 9 i1)1ZS Llk co t,--,) Phone#: 2---QY - ;32/ - Mailing Address: Yid, fj6�C 1y� City: 'State: Zip: Site Address: E ull%y1 City: 6/1,11al-7 State: LJi-3-Zip: Parcel #: Legal Description: Lien/Title Holder: & /714Ls r,Acr,C,3 Address: 1),b . 6o X J `f 4 City: 2*tate: LJQ4 Zip:6 Contractor: Phone #: .360-/-4/- 6,-30 ) 02, P.o• box I� /� � wA �85 Address: 7�/�/ gj-C�o/G� � City: (//t1,1 State: Zip:'EK-522/ Contractor Registration #: /1g .PC oz'S Expiration Date: /,�• // Building Square Footage(existing & proposed): 1" / 2n / 3rd / Building Use: _ dejl g2 Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: Wet f1f Dry New System: Standpipe: Wet .X Dry Modification: AFA: Hood & Duct: Dry Chem: Wet Chem: Fire Pump: UL certified Monitoring company: Phone #: Contractors Bid Price: \\CLUSTERI_HOME_SERVER\HOME\COMMON\Community Development\BUILDING\Fire Protection System Permit Application.doc 1 Plan Submittal Requirements Your plan submittal shall include the following: • Plans shall be on standard 24" x 36"paper, drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and/or area separation walls, partitions, stairway enclosures, concealed spaces, etc. • Cut sheets and/or references for all new devices. • Location/description of all new and existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floor plan. • Electrical riser diagram showing all zones, circuits, devices, and end —of— line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$168.50. A plan review fee will be calculated at 65%of the permit fee(minimum$109.50)and is due upon submittal of permit application. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire Marshal. By: / Date: v7z G \\CLUSTER I_HOME_SERVER\IiOME\COMMON\Community Development\BUILDING\Fire Protection System Permit Application.doc _ _ _ Fire Protection by Computer Design Amos ftft� Ind Uponor 5925 148th Street West o¢o.6eaz Apple Valley, MN 55124 v � (952) 891-2000 ow �r Job Name UNITED BUILDER @ CHOW -Two Head Calculation (H.6 & H.12) Building RESIDENTIAL Location 260 E. UNION HEIGHT DR. UNION WA 98592 System 1 Contract 090514-45L Data File 090414-45L CHOW RESIDENCE.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Uponor Page 1 UNITED BUILDER @ CHOW -Two Head Calculation (H.6& H.12) Date 4/17/2009 HYDRAULIC DESIGN INFORMATION SHEET Name - UNITED BUILDER @ CHOW Date - 04/17/09 Location - UNION WA 98592 "Building - RESIDENTIAL System No. - 1 Contractor - AMERICAN PLUMBING CONT INC Contract No. - 090514-45L Calculated By - DEVON HUYNH Drawing No. - 1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height VARIES OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( ) l (X)2 ( ) 4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 9.14 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC43 I Elevation at Highest Outlet - 108 Feet Size 3/8 K-Factor 4.3 G Note: Temperature Rating 155 N Calculation Gpm Required 26.0005 Psi Required 52.63 At Ref Pt STR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 04/03/09 Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 57 Elev. R Residual (Psi) - 57 Other Well Flow (Gpm) - 300 Proof Flow Gpm S Elevation - 110 P Location: P L Source of Information: CITY SUPPLY Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C)' Uponor Page 2 UNITED BUILDER 9 CHOW -Two Head Calculation (H.6 & H.12) Date 4/17/2009 City Water Supply: Demand: C1 - Static Pressure : 57 D1 - Elevation -0.866 C2 - Residual Pressure: 57 D2 - System Flow 26.0005 C2 - Residual Flow 300 D2- System Pressure 52.632 Hose (Adj City) Hose ( Demand ) D3 - System Demand 26.0005 Safety Margin 4.368 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 R 60 E 50 40 30 20 10 50 D1100 150 200 250 300 350 400 450 FLOW ( N 11 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Uponor Page 3 UNITED BUILDER @ CHOW -Two Head Calculation (H.6& H.12) Date 4/17/2009 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90'Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Utb ProPEX Tee-Branch-Brass 2 .8 2 9.08 12.88 13.22 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 Uponor Page 4 UNITED BUILDER @ CHOW -Two Head Calculation (H.6& H.12) Date 4/17/2009 SUPPL Y ANAL YSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 57.0 57 300.0 57.0 26.0 52.632 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.12 108.0 4.3 9.14 13.0 T.29 108.0 10.42 H.18 108.0 13.38 H.21 108.0 16.74 T.39 108.0 21.72 H.19 108.0 27.98 T.38 108.0 28.86 T.35 108.0 28.29 H.16 108.0 26.36 H.15 108.0 24.82 T.26 108.0 22.45 H.10 108.0 21.85 HA 108.0 19.99 H.3 108.0 18.93 T.24 108.0 18.04 H.5 108.0 19.17 H.11 108.0 20.53 T.33 108.0 21.24 T.30 116.0 18.12 H.13 116.0 18.16 T.31 116.0 18.22 H.14 116.0 18.32 T.32 116.0 18.35 H.6 108.0 4.3 9.14 13.0 H.2 108.0 12.97 T.23 108.0 17.07 HA 108.0 17.42 H.17 108.0 21.45 T.36 108.0 21.64 H.20 108.0 21.7 T.27 116.0 18.14 H.9 116.0 18.16 H.7 116.0 18.22 T.25 116.0 18.23 H.8 116.0 18.26 S.1 104.0 35.29 MTR 110.0 43.56 STR 110.0 52.63 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Uponor Page 5 UNITED BUILDER @ CHOW -Two Head Calculation (H.6& H.12) Date 4/17/2009 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. ..C., or Ftng's Pe Pv ... Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn HA 2 12.88 0.671 1 Utb 0.8 3.000 9.140 K Factor=4.30 to 150.0 0.0 0.800 0.0 T.29 12.88 0.3363 0.0 3.800 1.278 Vel= 11.69 T.29 0.0 0.671 1 Utb 0.8 8.000 10.418 to 150.0 0.0 0.800 0.0 H.18 12.88 0.3364 0.0 8.800 2.960 Vel= 11.69 H.18 0.0 0.671 0.0 10.000 13.378 to 150.0 0.0 0.0 0.0 H.21 12.88 0.3363 0.0 10.000 3.363 Vel= 11.69 H.21 0.0 0.671 1 Utb 0.8 14.000 16.741 to 150.0 0.0 0.800 0.0 T.39 12.88 0.3364 0.0 14.800 4.978 Vel= 11.69 T.39 2.89 0.671 1 Utb 0.8 12.000 21.719 to 150.0 0.0 0.800 0.0 H.19 15.77 0.4891 0.0 12.800 6.261 Vel= 14.31 H.19 0.0 0.671 1 Utb 0.8 1.000 27.980 to 150.0 0.0 0.800 0.0 T.38 15.77 0.4889 0.0 1.800 0.880 Vel = 14.31 T.38 -26.00 0.671 2Utb 1.6 1.000 28.860 to 150.0 0.0 1.600 0.0 T.35 -10.23 -0.2192 0.0 2.600 -0.570 Vel = 9.28 T.35 0.0 0.671 1 Utb 0.8 8.000 28.290 to 150.0 0.0 0.800 0.0 H.16 -10.23 -0.2194 0.0 8.800 -1.931 Vel= 9.28 H.16 0.0 0.671 0.0 7.000 26.359 to 150.0 0.0 0.0 0.0 H.15 -10.23 -0.2193 0.0 7.000 -1.535 Vel= 9.28 H.15 0.0 0.671 1 Utb 0.8 10.000 24.824 to 150.0 0.0 0.800 0.0 T.26 -10.23 -0.2194 0.0 10.800 -2.370 Vel = 9.28 T.26 3.97 0.671 1 Utb 0.8 6.000 22.454 to 150.0 0.0 0.800 0.0 H.10 -6.26 -0.0885 0.0 6.800 -0.602 Vel = 5.68 H.10 0.0 0.671 0.0 21.000 21.852 to 150.0 0.0 0.0 0.0 H.4 -6.26 -0.0886 0.0 21.000 -1.861 Vel = 5.68 H.4 0.0 0.671 0.0 12.000 19.991 to 150.0 0.0 0.0 0.0 H.3 -6.26 -0.0886 0.0 12.000 -1.063 Vel = 5.68 H.3 0.0 0.671 0.0 10.000 18.928 to 150.0 0.0 0.0 0.0 T.24 -6.26 -0.0885 0.0 10.000 -0.885 Vel = 5.68 T.24 13.11 0.671 1 Utb 0.8 10.000 18.043 to 150.0 0.0 0.800 0.0 H.5 6.85 0.1046 0.0 10.800 1.130 Vel = 6.21 H.5 0.0 0.671 0.0 13.000 19.173 to 150.0 0.0 0.0 0.0 HA 1 6.85 0.1046 0.0 13.000 1.360 Vel= 6.21 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Uponor Page 6 UNITED BUILDER @ CHOW -Two Head Calculation (H.6& H.12) Date 4/17/2009 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.11 0.0 0.671 1 Utb 0.8 6.000 20.533 to 150.0 0.0 0.800 0.0 T.33 6.85 0.1047 0.0 6.800 0.712 Vel = 6.21 T.33 -2.89 0.671 0.0 9.000 21.245 to 150.0 0.0 0.0 -3.465 T.30 3.96 0.0380 0.0 9.000 0.342 Vel = 3.59 T.30 -1.07 0.671 1 Utb 0.8 1.000 18.122 to 150.0 0.0 0.800 0.0 H.13 2.89 0.0211 0.0 1.800 0.038 Vel = 2.62 H.13 0.0 0.671 1 Utb 0.8 2.000 18.160 to 150.0 0.0 0.800 0.0 T.31 2.89 0.0211 0.0 2.800 0.059 Vel= 2.62 T.31 -0.29 0.671 1 Utb 0.8 5.000 18.219 to 150.0 0.0 0.800 0.0 H.14 2.6 0.0174 0.0 5.800 0.101 Vel= 2.36 H.14 0.0 0.671 1 Utb 0.8 1.000 18.320 to 150.0 0.0 0.800 0.0 T.32 2.6 0.0172 0.0 1.800 0.031 Vel = 2.36 T.32 1.36 0.671 1 Utb 0.8 16.000 18.351 to 150.0 0.0 0.800 3.465 T.26 3.96 0.0380 0.0 16.800 0.638 Vel = 3.59 0.0 3.96 22.454 K Factor= 0.84 H.12 0.12 0.671 0.0 15.000 9.140 to 150.0 0.0 0.0 0.0 H.6 0.12 0.0001 0.0 15.000 0.001 Vel = 0.11 H.6 13.00 0.671 0.0 11.000 9.141 K Factor=4.30 to 150.0 0.0 0.0 0.0 H.2 13.12 0.3477 0.0 11.000 3.825 Vel = 11.90 H.2 0.0 0.671 1 Utb 0.8 11.000 12.966 to 150.0 0.0 0.800 0.0 T.23 13.12 0.3477 0.0 11.800 4.103 Vel = 11.90 T.23 0.0 0.671 0.0 1.000 17.069 to 150.0 0.0 0.0 0.0 H.1 13.12 0.3480 0.0 1.000 0.348 Vel = 11.90 H.1 0.0 0.671 1 Utb 0.8 1.000 17.417 to 150.0 0.0 0.800 0.0 T.24 13.12 0.3478 0.0 1.800 0.626 Vel = 11.90 0.0 13.12 18.043 K Factor= 3.09 T.33 2.89 0.671 1 Utb 0.8 9.000 21.245 to 150.0 0.0 0.800 0.0 H.17 2.89 0.0211 0.0 9.800 0.207 Vel = 2.62 H.17 0.0 0.671 1 Utb 0.8 8.000 21.452 to 150.0 0.0 0.800 0.0 T.36 2.89 0.0212 0.0 8.800 0.187 Vel = 2.62 T.36 0.0 0.671 1 Utb 0.8 2.000 21.639 to 150.0 0.0 0.800 0.0 H.20 2.89 0.0211 0.0 2.800 0.059 Vel = 2.62 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Uponor Page 7 UNITED BUILDER @ CHOW - Two Head Calculation (H.6 & H.12) Date 4/17/2009 Hyd. Oa Dia. Fitting Pipe Pt Pt •Ref. "C" or Ftng's Pe Pv """' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.20 0.0 0.671 0.0 1.000 21.698 to 150.0 0.0 0.0 0.0 T.39 2.89 0.0210 0.0 1.000 0.021 Vel= 2.62 0.0 2.89 21.719 K Factor= 0.62 T.30 1.07 0.671 1 Utb 0.8 6.000 18.122 to 150.0 0.0 0.800 0.0 T.27 1.07 0.0032 0.0 6.800 0.022 Vel = 0.97 T.27 0.0 0.671 0.0 5.000 18.144 to 150.0 0.0 0.0 0.0 H.9 1.07 0.0034 0.0 5.000 0.017 Vel = 0.97 H.9 0.0 0.671 0.0 16.000 18.161 to 150.0 0.0 0.0 0.0 H.7 1.07 0.0034 0.0 16.000 0.054 Vel = 0.97 H.7 0.0 0.671 1 Utb 0.8 2.000 18.215 to 150.0 0.0 0.800 0.0 T.25 1.07 0.0036 0.0 2.800 0.010 Vel = 0.97 T.25 0.30 0.671 1 Utb 0.8 5.000 18.225 to 150.0 0.0 0.800 0.0 H.8 1.37 0.0053 0.0 5.800 0.031 Vel= 1.24 H.8 0.0 0.671 0.0 18.000 18.256 to 150.0 0.0 0.0 0.0 T.32 1.37 0.0053 0.0 18.000 0.095 Vel = 1.24 0.0 1.37 18.351 K Factor= 0.32 T.31 0.30 0.671 0.0 17.000 18.219 to 150.0 0.0 0.0 0.0 T.25 0.3 0.0004 0.0 17.000 0.006 Vel= 0.27 0.0 0.30 18.225 K Factor= 0.07 T.38 26.00 0.862 1 T 7.528 10.000 28.860 to 150.0 0.0 2.904 1.732 S.1 26.0 0.3641 0.0 12.904 4.698 Vel = 14.29 SA 0.0 1.112 2E 3.168 100.000 35.290 to 150.0 0.0 3.168 -2.599 MTR 26.0 0.1053 0.0 103.168 10.868 Vel= 8.59 MTR 0.0 2.435 1 E 8.474 5.000 43.559 to 150.0 1 T 16.949 26.835 9.000 ' Fixed loss = 9 STR 26.0 0.0023 1 G 1.412 31.835 0.073 Vel= 1.79 0.0 26.00 52.632 K Factor= 3.58 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Bulletin 006 Rev.D ® Model RFC43 (SIN RA0612) co RialmlabiModel RFC49 (SIN RA0616) - Flat Concealed g Residential Sprinklers A Concealed Residential . . Sprinkler engineered for a . minimum design density of 0.05 gpm/ftz with low GPM ' requirements. c i; Features ''` 1 . Very low water flow requirements. s • " 2. 1/2" (13mm) Total adjustment. _ _ - 3. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. a' r Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada(cULus) 2. NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC43 and RFC49 Concealed Residential Sprinklers The RFC43 and RFC49 are UL Listed Residential Sprinklers are fast response residential fusible solder link automatic to be installed in the residential portions of any occupancy in sprinklers. Residential sprinklers differ from standard accordance with NFPA 13, 13R,& 13D. sprinklers primarily in their response time and water The RFC43 and RFC49 can reduce the need for precise distribution patterns. cutting of drop nipples. The threaded cover plate assembly Model RFC43 and RFC49 sprinklers discharge water in a can be adjusted without tools to fit accurately against the hemispherical pattern below the sprinkler deflector. ceiling. The fire protection system need not be shut down to Residential distribution patterns are higher and generally adjust or remove the cover plate assembly. contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge Application and Installation pattern required for residential sprinklers has demonstrated, The RFC43 and RFC49, for residential installations, use a in fire testing, an ability for controlling residential fires, and 165OF(74°C)fusible solder link in a tuning fork style sprinkler thereby providing significant evacuation time for occupants. frame with a drop-down deflector. This assembly is recessed The RFC43 and RFC49 Sprinklers provide the best form of into the ceiling and concealed by a flat cover plate. The cover fire protection by combining an attractive appearance and plate is attached to the skirt, using 135OF (57°C) ordinary 1/2"(13mm)of cover adjustment for ease of installation. The temperature classification solder. When the ceiling small diameter cover plate is easily and positively attached temperature rises,the solder holding the cover plate releases and blends into the ceiling,concealing the most dependable the cover allowing the deflector to drop into position and fire protection available,an automatic sprinkler system. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 exposing the sprinkler inside to ceiling temperature. The should be taken to prevent damage to the sprinkler. DO NOT subsequent operation of the solder link opens the waterway WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP and causes the deflector to drop into position to distribute the ASSEMBLY. MODEL RFC43 AND RFC49 CONCEALED discharging water in a hemispherical pattern below the SPRINKLERS MUST BE INSTALLED ONLY WITH 135OF sprinkler deflector. Any adjustment of thread engagement RATED COVERS. between the cover plate and cup will assure that the Cover assemblies provide up to y2" (13mm) of drop-down deflector is properly located below the ceiling. adjustment. Turn the cover clockwise until the flange is in The residential distribution pattern contains a finer droplet size contact with the ceiling. For the push-on/thread-off option, than a standard sprinkler, and the pattern produces the cover assembly is pushed onto the cup and final significantly higher wall wetting. adjustment is made by turning the cover clockwise until the After a 2 5/8 inch diameter hole is cut in the ceiling, the skirt flange makes full contact with the ceiling. Cover sprinkler is to be installed with the Model FC Wrench. When removal requires turning in the counter-clockwise direction. installing a sprinkler, the wrench is first positioned into the In ceilings that have a plenum space above the sprinkler, sprinkler/cup assembly and around the hexagonal body of the plenum space may have neutral or negative the sprinkler frame. The Wrench must bottom out against the pressurization but must not be positively pressurized. Inspect cup in order to ensure proper,safe installation. The sprinkler all sprinklers after installation to ensure that the gap between is then tightened into the pipe fitting. When inserting or the cover plate and ceiling and the 4 slots in the cup are all removing the wrench from the sprinkler/cup assembly, care open and free from any air flow impediment. Temperature Rating Sprinkler Cover Plate Max.Ambient Temp. 165°F/74°C 135°F/57°C 100°F/38°C Installation Data: RFC43 (SIN RA0612) Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch(mm) Factor Spacing Distance Distance between ft.(m) to Wall ft.(m) sprinklers,ft.(m) Flow Press. gpm(Lpm) psi(bar) 1/2"(15mm) 4.3 12 x 12(3.6x3.6) 6(1.83) 8(2.43) 12(45) 7.8(0.54) 1/2"(15mm) 4.3 14 x 14(4.3x4.3) 7(2.13) 8(2.43) 13(49) 9.1 (0.63) '/2"(15mm) 4.3 16 x 16(4.9x4.9) 8(2.43) 8(2.43) 13(49) 9.1 (0.63) 112"(15mm) 4.3 18 x 18(5.5x5.5) 9(2.74) 8(2.43) 18(68) 17.5(1.21) 1/2"(15mm) 4.3 20 x 20(6.Ox6.0) 10(3.05) 8(2.43) 21 (79) 23.8(1.64) Note: 1 bar= 100 Kpa Installation Data: RFC49 RA0616 Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch(mm) Factor Spacing Distance Distance between ft.(m) to Wall ft.(m) sprinklers,ft.(m) Flow Press. gpm(Lpm) psi(bar) 1/2"(15mm) 4.9 12 x 12(3.6x3.6) 6(1.83) 8(2.43) 13(49) 7.0(0.48) 1/2"(15mm) 4.9 14 x 14(4.3x4.3) 7(2.13) 8(2.43) 13(49) 7.0(0.48) 1/2"(15mm) 4.9 16 x 16(4.9x4.9) 8(2.43) 8(2.43) 13(49) 7.0(0.48) 1/2"(15mm) 4.9 18 x 18(5.5x5.5) 9(2.74) 8(2.43) 17(64.3) 12.0(0.83) 1/2" 15mm 4.9 20 x 20(6.Ox6.0) 10(3.05) 8(2.43) 20(75.7) 16.7(1.14) Note: 1 bar = 100 Kpa FOR SLOPED CEILING APPLICATIONS SEE RASCO BULLETIN 035. 2. Maintenance Model RFC43 and RFC49 Concealed Sprinklers should be 135°F(57°C). Cover plate assembly shall consist of a brass inspected quarterly and the sprinkler system maintained in cover plate and copper alloy retainer flange allowing a 1/2" accordance with NFPA 25. Do not clean sprinklers with soap cover plate adjustment. Any secure engagement between and water, ammonia or any other cleaning fluids. Remove the cover plate and the cup will assure that the drop-down dust by using a soft brush or gentle vacuuming.Remove any deflector is properly located below the ceiling. A plastic sprinkler cover plate assembly which has been painted(other protective cap shall be provided and factory installed inside than factory applied) or damaged in any way. A stock of the sprinkler cup to protect the drop-down sprinkler deflector spare sprinklers should be maintained to allow quick from damage,which could occur during construction before replacement of damaged or operated sprinklers. Prior to the cover plate is installed. Standard cover finish: [Chrome] installation, sprinklers should be maintained in the original [White][Specialty—specify]. Residential concealed sprinklers cartons and packaging until used to minimize the potential for shall be Reliable Model RFC43,SIN RA0612(Bulletin 006)or damage to sprinklers that would cause improper operation or Model RFC49, SIN RA0616(Bulletin 006). non-operation. Model RFC43 and RFC49 Residential Ordering Information over Plate Finishes Concealed Sprinkler Specification Specify: Standard Finishes Sprinklers shall be cULus Listed low flow residential 1. Sprinkler Model Chrome concealed sprinklers with drop-down deflector and 2. Cover Plate Finish white adjustable flat cover plate engineered for a minimum design 3. Thread-On or density of 0.05 gpm/ftz. Sprinkler frame and deflector shall be Push-On Feature Special Application of bronze frame construction having a 1/2" NPT thread. Finishes Thermal element shall consist of an approved black-painted Bright Brass beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring Black Plating washer and machined brass cap water seal assembly Black Paint containing no plastic parts. Sprinkler K-factor shall be nominal Off white 4.3(62.4), having a 7/16"orifice.Temperature rating shall be Satin Chrome Ordinary 165°F(740C); cover plate temperature rating to be I')Other colors and finishes available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. I' x 112" REDUCING TEE OR ELBOW 29"[66.7mml DIA. 24" [58.7mm] DIA — HOLE IN CEILING L J CUP 2"[50.8mm] MAX. FACE OF FI rTING TO FACE OF CEILING f DIMENSION r � CEILING iiiiiii 7-7 f�_ J" [12.7mm] MAX. I COVER ADJUSTMENT 3 " DIA COVER PLATE 184.1mm11 (4.8mmJ QO ;- ASSEMBLY SPRINKLER • aoermr COVER PLATE: 112" [12.7mml ADJUSTMENT 3. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Supertrol electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances,whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by: Recycled The Reliable Automatic Sprinkler Co.,Inc. HIM ';��'� (800) -1588 Sales Offices Paper 84 (800)848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address E.G.Printed in USA. 12106 PM 9999970261 Bulletin 176 Rev.A Model F1 Residential Sprinklers for Design Density of .10 gpm/ft2 D Model F1 Res Sprinlders engineered for the lowest flows to meet the minimum design density of.05 gpm/ff Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res 49 CCP Pendent 5. F1 Res 58 Pendent F1 Res 49,58&76 F1 Res 49,58&76 6. F1 Res 58 Recessed Pendent/F1 Recessed Pendent/F1 Recessed Pendent/FP 7. F1 Res 58 Recessed Pendent/FP 8. F1 Res 58 CCP Pendent 9. F1 Res 44 & 58 HSW 10. F1 Res 44 & 58 HSW Recessed HSW/F2 11. F1 Res 44 SWC 12. F1 Res 76 Pendent 13. F1 Res 76 Recessed Pendent/F1 14. F1 Res 76 Recessed Pendent/FP F1 Res 49,58&76 F1 Res 44&58 15. F1 Res 76 CCP Pendent CCP Pendent Recessed HSW/F2 Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW F1 Res 44 SWC Patents US Patent No. 6,516,893 applies to the Model F1 Res 49& 58 Pendent Sprinklers Product Description Technical Data: Model F1 Res Pendent sprinklers (Figs. 1, 2, 3 & 4) • Thermal Sensor: Nominal 3mm glass-bulb combine excellent durability, high sensitivity glass-bulb • Sprinkler Frame: Brass Casting and low profile decorative design. • Sprinklers'Pressure Rating : 175 psi The 3mm glass-bulb pendent sprinklers permit the Factory Hydrostatically Tested to 500 psi efficient use of residential water supplies for sprinkler . Thread Size: 112' NPT(R1/2) coverage in residential fire protection design. . Kfacbr 4.9(Ad&O-F1 Res 49 Pendent Sprinkler The low flow F1 Res sprinklers are specially 5.8(A.Lo-F1 Res58Rndent&HSWSprin14er engineered for fast thermal response to meet the 7.6(Actual)-F1 Res 76 Pendent Sprinkler sensitive fire protection application needs of the latest 4.4(Actual)-F1 Res 44 HSW Sprinkler residential market standards (UL 1626 Standard *). • Density: Minimum 0.10 gpm/ft2 Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. * Effective date 7112102 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 Res Sprinklers are used for Residential Fire Example No. 1 Protection according to UL 1626 Standard*. Be sure Room Size= 12 ft x 20 ft(3.6 m x 6.1 m) that orifice size, temperature rating, deflector style and Coverage Area= 12 x 20 = 240 ft2(22.3 m2) sprinkler type are in accordance with the latest Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm published standards of The National Fire Protection Using an F1 Res 49 Pendent Sprinkler, K=4.9 Association or the approving authority having Pressure= (24/4.9)2 = 24 psi (1.65 bar) jurisdiction. The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) When using F1 Residential Sprinklers for systems coverge area using the baseline density of 0.05 design to NFPA 13D or NFPA 13R, use listed area of gpm/ft will be 20 gpm @ 16.7 psi (75.7 Umin @ 1.14 coverage and minimum flow and pressure requirements bar). Therefore,the minimum flow required is 24 gpm @ shown in Bulletin 135. 24 psi (90.8 Umin @ 1.65 bar). For systems designed to NFPA 13, use information in this bulletin.The number of design sprinklers shall be the Example No. 2 most hydraulically demanding sprinklers as required by Room Size= 8 ft x 20 ft (2.4 m x 6.1 m) NFPA 13. Flows and pressures can not be below the Covera e Area- 8 x 20 - 160 ft2(14.9 m2 baseline flows and pressurers. Flow @ 0.10 gpm/ft2 density= 160 x 0.10 ) 16 gpm NFPA 13 Using an F1 Res 49 Pendent Sprinkler, K=4.9 For residential sprinkler systerrrrI�,s designed to NFPA 13, Pressure= (16/4.9)2 = 10.7 psi (0.74 bar) a minimum density of 0.1 gpm/fe must be provided over The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) the"design area"that includes the four(4)hydraulically covera e area using the baseline density of 0.05 most demanding sprinklers for the actual coverage gpm/ft2gwill be 20 gpm @ 16.7 psi (75.7 Umin @ 1.14 areas being protected by the 4 sprinklers. The minimum bar). Therefore,the minimum flow required is 20 gpm @ required discharge from each of the four most 16.7 psi (75.7 Umin @ 1.14 bar). hydraulically demanding sprinklers shall be the greater of the following: 1.The flow rates given in the Reliable Residential ExampleNo. 3 Sprinkler Technical Bulletins referenced in Table A Room Size= 10 ft x 16 ft(3.0 m x 4.91 m) for NFPA 13D and 13R as a function of temperature Coverage Area= 10 x 16 = 160 ft2(14.9 m2) rating and maximum allowable coverage area (for Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm actual coverage areas less than or between those Using an F1 Res 76 Pendent Sprinkler, K=7.6 indicated in the respective technical bulletin, it is The baseline flow for a 16 ft x 16 ft coverage area is 21 required to use the minimum required flow for the gpm @ 7.6 psi(79.5 Umin @ 0.52 bar). Therefore, the next largest coverage area); or minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 2.A minimum discharge density of 0.1 gpm/ft2 Umin @ 0.52 bar). applied over the"design area"consisting of the four most hydraulically demanding sprinklers for the Example No. 4 actual coverage areas being protected by the four Room Size= 14 ft x 18 ft(4.3 m x 5.5 m) sprinklers. The maximum dimension of the actual Coverage Area= 14 x 18 = 252 ft2(23.6 m2) coverage area cannot be any greater than the 2 maximum coverage area indicated in the technical Flow @ 0.10 gpm/ft density= 252 x 0.10 = 25.2 gpm (94.6 Umin) bulletins referenced in Table A. Design Note: Using the AS = S x L method to Using F1 Res 76 Pendent Sprinkler, K=7.6 determine the sprinkler protection area of coverag Pressure= (252/7.6) = 11 psi (0.76 bar) in accordance with NFPA 13, apply the 0.1 gpm/ft The baseline flow and pressure of an 18 ft x 18 ft density to this area to determine the minimum coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 required flow. Compare this flow to the minimum bar). Therefore,the minimum flow and pressure is 25.2 0.05 gpm/ft cULus Listed flow for the appropriate gpm @ 11 psi (94.6 Umin @ 0.76 bar). coverage area in the technical bulletin for the specific residential sprinkler. If the flow stated in the In general residential sprinklers require technical bulletin is less than the calculated 0.1 flows and pressures as listed for D.05 gpm/ft density flow required, the .1 density flow densities to achieve the proper spray pattern must then be used in the equation Q=K P, solving so the flows and pressures at 0.05 density are for P, to establish the minimum required pressure the baseline flows and pressures. Flows and using the sprinkler K-factor. Note: In many cases pressures below the listed 0.05 density shall the listed flow of individual residential sprinkler not be used. may exceed the required minimum 0.05 gpm/ft density.Reliable has available residential sprinklers with larger K-factors (K=5.8 and K=7.6) that wi provide lower pressure demands for 0.1 gpm/ft densities in NFPA 13 residential applications. 2. Installation Models F1 Res sprinklers are to be installed as use only the Model GFR2 Sprinkler wrench. Use of shown. Model F1, F2 and FP Escutcheons, illustrated wrenches other than those specified may damage herewith,are the only recessed escutcheons to be used these sprinklers. with Model F1 Res sprinklers. Use of any other Note:A`leak tight'sprinklerjoint can be obtained with recessed escutcheon will void all approvals and the following torque: warranties. For installing Model F1 Res Pendent • 3/a" NPT(R3/4)- 14-20 ft-Ibs (19-27.1 N-m) sprinklers use only the Model D sprinkler Wrench; for . 1/2" NPT(R1/2)-8-18 ft-Ibs(10.8-24.4 N-m) installing Models F1 Res Recessed Pendent, CCP Do not tighten sprinklers over maximum sprinklers use only the Model GFR2 sprinkler wrench; recommended torque. It may cause leakage or for installing Model F1 Res recessed HSW sprinklers impairment of the sprinklers. • Model F1 Res 49, 58 & 76 • Model F1 Res 49, 58 & 76 Pendent Recessed Pendent/ F1/F2 F1 escutcheon, /" (19mm) adjustment Note: See escutcheon table for dimensions. 2 I/1•HOLE OR 15,.2m.1/ ' ml j x 1/2 I1011l AG,.VS/SPIP6IlLL£t FACE or Rrrm TO ctxlwL:aucwsw+: . 1 jf�f/ J/16-15/16(FI ESCU7CKpy) !/16-=f/16(F2 ESCUTVEM) AL1N/$i1/ENI I n. ) i IJ5FGOJ IJ5FG02A z 27/u•W [722—] Fig. 1 Fig. 2 3. Technical Data: F1 Res 49 Pendent and Recessed Pendent Escutcheon*, F1 or F2, Data: Nominal Spnnkler Max. Max Sprinkler Face of fitting to Thread Orifice Temp. Actual Adjustment "A" p Pressure � Len Type ceiling SYae Inch Ratin psi Tem K Inch Inch(mm) Inch(mm) Inch mm (mm) °F °C (bar) °F OC Factor (mm) , Min.=/~ (19.1) F1 /,(19.0) Max.=14 „ 38.1 116 s(4.7-24.0) y„NPT ,s•(11) 155 68 175(12) 100 38 4.9 2.25(57) R 175 79 150 66 F2 /22(12.7) M�_'%s„(38$ 3/,s-"/,s(4.7-17.4) *Note: Escutcheons F1 or F2 may be used with Model F1 Res 49&58 Recessed Pendent Sprinkler **Baseline flows and pressures for 0.05 density Deflector-to-ceiling *Deflector-to-ceiling Maximum 1"(25mm)to 4"(100mm) Maximum 4"(100mm)to 8"(203mm) Max.Sprinkler Sprinkler Max.Sprinkler Sprinkler Flow Pressure Flow Pressure Sftac�g Identification Spacing Identification gpm(Lpm)' psi(bar) Number SIN ft m g gpm(Lpm)'' psi(bar) Number SIN 12 x 12 3.6x3.6 13 49 7.0 0.48 12 x 12 3.6x3.6 15 57 9.4 0.65 14 x 14 4.3x4.3 13 49 7.0 0.48 14 x 14 4.3x4.3 16 60.5 10.6 0.73 16 x 16 4.9x4.9 13 49 8 R3516 16 x 16 4.9x4.9 17 64.3 12.0 0.83 R3516 18 x 18 5.5x5.5 17 64.3 12.400.83 18 x 18 5.5x5.5 19 72 15.0 1.0 20 x 20 6.1 x6.1 20 75.7 4) 20 x 20 6.1 x6.1) 22 83.2 20.2 1.4 *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth=7"(178mm) 2.Beam spacing at or greater than 7.5 ft.(2.3m)on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Sprinkler Thread Orifice Temp. Pressure Ambient K Length Size Inch Ratin psi Temp. I Factor Inch (mm) OF I °C (bar) T oC (mm) 1/2'NPT %.(13) 1551 68 175(12) 100 38 5.8 2.25(57) (R/2) 1751 79 150 66 **Baseline flows and pressures for 0.05 density Max. Sprinkler Ceiling-to- Sprinkler Spacing Flow( m Psi(bar) Deflector Identification ft m gP ( P ) (bar) Inch(mm) Number SIN 12 x 12 3.6x3.6 16 61 7.6 0.53 14 x 14 4.3x4.3 16 61 7.6 0.53 16 x 16 4.9x4.9 16 61 7.6 0.53 1-4(25 100) R3513 18 x 18 5.5x5.5 19 72 10.8 0.75 20 x 20 6.1 x6.1 22 83.3 14.4 1.0 **Calculate for a.10 density but in no case go below the baseline flows&pressures 4. Technical Data: F1 Res 76 Pendent and Recessed Pendent Nominal Sprinkler Max Mw. Sprinkler Thread Orifice Temp Pressure Ambient K Length See Inch PlEft psi TomFacior Inch (mm) °F °C (bar) °F °C (mm) NPT ,�z•(13.5) 155 68 175(12) 100 38 7.6 2.25(57) T Adjustment "A" Face of fitting to (R3,) 175 79 150 66 YPe Inch(mm) Inch(mm) Ind Ii 7m F1 %(19.0) Min.=3/4" (19.1) %-ly,(4.7-24.0) *Baseline flows and pressures for 0.05 density Max.=1' " 38.1 Max.Sprinkler Sprinkler F2 (12.7) Max.=1 6"(38.81j �6-'�s(4.7-17.4) Flow Pressure Spacing gpm(rpm) psi(bar) Identification ft m Number SI 12 x 12 3.6x3.6 21 7.6 0.53 14 x 14 4.3x4.3 21 7.6 0.53 16 x 16 4.9x4.9 21 7.6 0.53 R7618 *Calculate for a .10 density but in no case 18 x 18 5.5x5.5 21 7.6 0.53 go below the baseline flows& pressures 20 x 20 6.1 x6.1 23 9.2 0.63 • Model F1 Res 49, 58 &76 Model F1 Res 49, 58 &76 CCP Pendent Recessed Pendent/FP FP push-on/thread-off escutcheon 2 5/8"[66.7mm] DIA. 2 5m'D"l6&7 1 "a[X.CE/UN6 2 5/16"041. HOLE IN CEILING [58.7mm] 2 5/16"D1l CUP - L56.7 1 CUP `--i----� 1"X 1/2"REDUCER r -- CUP \ i I 1 1'X 1/2-REDUCER -__I--_-_ CEILING _ 1 1/4"[31.5mml 1\ i A MAX. FACE OF FITTING \ / I r0 FACE OF CEILING 1 I ", DIMENSION J "A" L I DEXwac COVER ADJUSTMENT 9" I HEIGHT 1 r/Y L! i jrux. FA OFF FCEIL TO FACE [OF CElM•G O"QRSrOw 3 5/16"DA 135FG04C [84.I mm] 1/FP(1-1 11 RES 49. 58 & 76 CCP PEND. ADJV$TWAff A"+ Fig. 3 Fig. 4 NOTE: The F1 Res 76 will use a 1"x 3/4"reducer. 5. Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/ FP CCP O tions Data: Nominal SPri A-,sen y Max Max Spri ider "A" Thread Orifice Temp. TWp6 Pressure Ambieit K Length Cover Adjustment CCP Height Size Inch R-&�g Fhftpsi Term Fac or Inch Inch mm Inch(mm) (mm) (bar) 'C (mm) 12.7 16 24 3 4.7 3 19 Yz NPT2.25(13/z) 57 316"(11) 155 68 135 57 175(12) 100 38 4.9 (57) *Baseline flows and pressures for 0.05 density FP Data "A": Max.Sprinkler Flow Pressure Sprinkler FP Position Inc"A" Spacing gpm��) psi�) Identification ft m Number SIN Max.Recessed 11 12 x 12 3.6x3.6 13 49 7.0 0.48 Min. Recessed 1 24 14 x 14 4.3x4.3 13 49 7.0 0.48 Note: Sprinklers shown in Fig. 3 and Fig. 4 are not 16 x 16 4.9x4.9 14 53 8.2 0.56 R3516 suitable for installation in ceilings which have 18 x 18 5.5x5.5 18 68.1 13.5 0.93 positive pressure in the space above. 20 x 20 6.1 x6.1 20 75.7 16.7 1.14 Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Nominal Max Max 90*ler Thread Orifice R Temp. Pressure Acttbient K Length Sim Inch �ng psi Temp. Factor Inch (mm) OF ,C ,F I ,C (bar) of (mm) NPT Yz'(13) 155 68 135L 175(12) 100 38 5.8 2.25(57) *Baseline flows and pressures for 0.05 density Max.Sprinkler Flow Sprinkler Spacing gpm ) � Identification ft m Number SIN 12 x 12 3.6x3.6 16 61 7.6 0.53 14 x 14 4.3x4.3 16 61 7.6 0.53 16 x 16 4.9x4.9 16 61 7.6 0.53 R3513 18 x 18 5.5x5.5 19 72 10.8 0.75 20 x 20(6.1 x6.1) 22 83.3 14.4 1.0 Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP CCP Nominal � Max S�xiiWer Thread Orifice Temp. yT Presaie Ambient K Length Sim Inch Rating Palling psi Temp. Faraor Inch (mm) ,F °C °F °C °F °C ( ') 3/4"NPT 1%' 155 68 100 38 2.25 R3/4 13.5 175 79 135 57 175(12) 150 66 7'6 57 *Baseline flows and pressures for 0.05 density Max.Sprinkler Flow Pure Sprinkler Spacing 9--m(Lp m) si ) Identification ft m Number SIN 12 x 12 3.6x3.6 21 7.6 0.53 14 x 14 4.3x4.3 21 -7.6 0.53 16 x 16 4.9x4.9 21 7.6 0.53 R7618 "Calculate for a.10 density but in no case 18 x 18 5.5x5.5 22 8.4 0.58 go below the baseline flows&pressures 20 x 20 6.1 x6.1 25 10.8 0.74 6. • Model F1 Res 44 & 58 HSW Model F1 Res 44 & 58 Recessed HSW/F2 a' F2 escutcheon,y" 13mm) adjustment Technical Data: F1 Res 44 HSW & HSW/F2 Escutcheon, F2, Data: Nominal T N�c Max SM*Ier Face of Fitting She Inch � �n ATmbiert Fedor � Type kic(rrw to k�chmm (mm) T -C M80 T I ';C (MM) F2 13 a 4.7-17.4 (10) 155 68 175(12) 100 38 4.4 2.45(62) R/z 175 79 1501 66 *Baseline flows and pressures for 0.05 density Max.Sprinkler Ceiling to- Sprinkler Temp. Flow Pure Sprinkler Spacing Deflector Rating 9pm psi(bar) Identification ft(m) Inch(mm) F(`C) (Lpm) Number(SIN) 12 x 12 3.6x3.6 155 68 175 79 12 45.4 7.5 0.52 14 x 14 4.3x4.3 155 68 175 79 14 53.0 10.2 0.71 16 x 16 4.9x4.9 4-6 155 68 175 79 16 60.6 13.3 0.92 16 x 18 4.96.5 (101-152) 155 68 175 79 18 68.1 16.8 1.16 18 x 18 5.5x5.5 155 68 175 79 19 72.0 18.7 1.29 16 x 20 4.9x6.1 155 68 175 79 23 87.1 27.4 1.89 R3531 12 x 12 3.6x3.6 155 68 175 79 14 53.0 10.2 0.71 14 x 14 4.3x4.3 155 68 175 79 16 60.6 13.3 0.92 16 x 16 4.9x4.9 6-12 155 68 175 79 17 64.4 15.0 1.04 16 x 18 4.9x5.5 (152-305) 155 68 175 79 20 75.7 20.7 1.43 16 x 20 4.9x6.1 155 68 175 79 23 87.1 27.4 1.89 'Calculate for a.10 density but in no case go below the baseline flows&pressures 7. • Model F1 Res 44 SWC e"to 12' [101.60mm To 1 1/I•[J 1.75mm]JW-imum 304.80mm] Foce Of Fitting PUSH ON COVER. THEN To Wall 0lmansion TURN TO ACVUST UN77L TIGHT AGANST WALL. i'X 1/2'Reducer 1 �l Recommended i1 Wo17 Hole 2 5/16 2 5/8' [58.71mm]'T --- - ---- J 5/16- f [66.68mm] Dio. [8<.14mm] Diaj Dio. i TURN COLLAR UNT/L TIGHT AGAINST SPRINKLER WRENCH BOSS. 121 (a2.07mmJ 12-[12.70mm] Adjustment F1 RES 44 SWC Fig. 5 I Technical Data: F1 Res 44 SWC Nominal Spiinkler ODWT Max Max Thread Orifice Temp. PreSSM AmbierltTerrp K SLE Inch Ratlixg - psl Fader (mm) -F j -C °F °C (bar) °F qC (MM) '/2R 2) y•(10) 155 1 68 135 57 175(12) 100 38 4.4 2.45(62) *Baseline flows and pressures for 0.05 density A Max.Sprinkler Flow Sprinkler Spacing Deflector Ceiling-to- 9Pm Pressure Identification ft(m) Inch mm) (�) psi(bar) Number(SIN) 12 x 12 3.6x3.6 13 49.2 8.7 0.60 14 x 14 4.3x4.3 4-6 14 53.0 10.2 0.71 16 x 16 4.9x4.9 (101 52) 17 64.3 15.0 1.1 16 x 18 4.9x5.5 19 71.8 18.7 1.13 16 x 20 4.9x6.1 23 87.1 27.4 1.89 R3531 12 x 12 3.6x3.6 14 52.9 10.2 0.71 14 x 14 4.3x4.3 6-12 15 56.7 11.7 0.81 16 x 16 4.9x4.9 (152-305) 18 68.1 16.8 1.16 16 x 18 4.9x5.5 20 75.6 20.7 1.43 . *Calculate for a.10 density but in no case go below the baseline flows& pressures i I 8. I Technical Data: F1 Res 58 HSW & HSW/F2 Escutcheon, F2, Data: Nominal Sprinkler Max. Max Sprinkler Adjustment Face of Fitting Thread Orifice Temp. Pressure ArobleM K Length Type Inch(mm to wall Size Inch Rating_ psi T Factor Inch Inch mm (mm) IF °C (bar) 'F 'C (mm) F2 13 3 Y16 4.7-17.4 '/2RNPT Y2•(13) 155 68 175(12) 100 s 5.8 2.45(62) *Baseline flows and pressures for 0.05 density MWL Sprinkler Ceilin "to- Sprinkler Temp. Flow Pressure Sprinkler Spacing m) Deflector F ti C) ( ) psi(bar) NumIdenbification er(SIN)Inch(mm 12 x 12 3.6x3.6 155 68 175 79 16 60.6 7.6 0.53 14 x 14 4.3x4.3 155 68 175 79 18 68.2 9.7 0.67 16 x 16 4.9x4.9 4-6 155 68 175 79 21 79.5 13.2 0.91 16 x 18 4.9x5.5 (101-152) 155 68 175 79 25 94.7 18.6 1.28 16 x 20 4.9x6.1 155 68 175 79 29 109.8 25 1.73 R3533 12 x 12 3.6x3.6 155 68 175 79 22 83.3 14.4 1.0 14 x 14 4.3x4.3 6-12 155 68 175 79 22 83.3 14.4 1.0 16 x 16 4.9x4.9 (152-305) 155 68 175 79 26 98.4 20.1 1.39 16 x 18 4.94.5 155 68 175 79 31 117.4 28.6 1.97 *Calculate for a.10 density but in no case go below the baseline flows&pressures Finishes(') Standard Finishes Ordering Information - Specify: Sprinkler F1 F2 FP Escutcheons 1. Sprinkler Model Bronze Brass Chrome Plated Bright Chrome Plated 2. Sprinkler Type White Polyester Coated White Painted 3.Temperature Rating Special Application Finishes 4. Sprinkler Finish Sprinkler F1 F2 Escutcheons Bright Brass Bright Brass 5. Escutcheon Finish Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult factory for details. 9. I Maintenance Model F1 Res 49, F1 Res 58 & F1 Res 76 Sprinklers Model F1 Res 49 & 58 Recessed Pendent/F1, should be inspected quarterly, and the sprinkler system Model F1 Res 49 &58 Recessed Pendent/172, maintained in accordance with NFPA 25, 13, 13D, and Model F1 Res 49 & 58 Recessed Pendent/FP 13R. Do not clean sprinkler with soap and water,Ammonia Sprinklers shall be [cULus Listed] [New York City MEA or any other cleaning fluids. Remove dust by using a soft Approved (258-93-E)] low flow residential recessed brush or gentle vacuuming. Remove any sprinkler which pendent sprinklers engine red to provide a minimum has been painted(other than factory applied)or damaged design density of 0.10 gpmover the listed coverage area. in any way. A stock of spare sprinklers should be Listed flows as specified by the manufacturer's technical maintained to allow quick replacement of damaged or data sheets are to be used. Residential sprinklers shall be operated sprinklers. Prior to installation, sprinklers should installed in conformance with the manufacturer's installation remain in the original cartons and packaging until used. guidelines and the applicable installation standard. Where This will minimize the potential for damage to sprinklers that pendent residential sprinklers are installed under sloped could cause improper operation or non-operation. ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance Model F1RES 49 Residential listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" Sprinkler Specifications NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic Model F1 Res 49 & 58 Pendent parts, and having a temperature rating of [155°F (680C)] Sprinklers shall be [cULus Listed] [New York City MEA [1750F(790C)]. Sprinklers shall have a nominal K-factor of Approved (258-93-E)] low flow residential pendent 4.9(70). Standard finish: [Bronze] [Chrome-plated] [White sprinklers engineered to provide a minimum design Polyester] [Special finish-specify]. Recessed escutcheon density of 0.10 gpm/ft2 over the listed coverage area. assembly shall be a steel, two-piece escutcheon [with '/2" Listed flows as specified by the manufacturer's technical adjustment(Model F2)][with 3/a' adjustment(Model F1)] [of data sheets are to be used. Residential sprinklers shall be push-on and thread off design with 1/2" adjustment(Model installed in conformance with the manufacturer's FP)]. Standard finish shall be[brass][bright chrome] [white installation guidelines and the applicable installation painted]. Residential recessed pendent sprinklers shall be standard. Where pendent residential sprinklers are Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1] installed under sloped ceilings having a pitch of up to[4/12] [Model F1 Res 49&58 Recessed Pendent/F2] [Model F1 [8/12], the sprinklers shall be listed for such use. Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513 Deflector-to-ceiling distance listing shall be 1" to 8" (Bulletin 135). maximum.Sprinkler frame and deflector shall be of bronze Model F1 Res 49&58 CCP Pendent(Concealed) frame construction having a '/2" NPT thread. Water seal Sprinklers shall be [cULus Listed] [New York City MEA assembly shall consist of a Teflon-coated Belleville spring Approved 258-93-E low flow residential concealed washer and top-loaded extruded cup with 3 mm glass bulb sprinklersp engineered to provide a minimum design containing no plastic parts, and having a temperature density of 0.10 gpm/ft2 over the listed coverage area. rating of [1550F (680C)] [1750F (79°C)]. Sprinklers shall Listed flows as specified by the manufacturer's technical have a nominal K-factor of 4.9 & 5.8. Standard finish: data sheets are to be used. Residential sprinklers shall [Bronze][Chrome-plated][White Polyester][Special finish- be installed in conformance with the manufacturer's specify]. Residential pendent sprinklers shall be Reliable installation guidelines and the applicable installation Model F1 Res 49&58,SIN R3516&R3513(Bulletin 135). standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155OF (681C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1/2" cover plate adjustment. Cover plate temperature rating shall be 1350F(571C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 49&58 CCP, SIN R3516& R3513 (Bulletin 135). 10. Model F1 Res 44 & 58 Horizontal Sidewall Model F1 Res 76 Recessed Pendent/F1, Sprinkler Model F1 Res 76 Recessed Pendent/172, Sprinklers shall be[cULus Listed] [New York City MEA Model F1 Res 76 Recessed Pendent/FP Approved (258-93-E)] low flow residential horizontal Sprinklers shall be [cULus Listed] low flow residential sidewall sprinklers engineered to provide a minimum recessed pendent sprinklers engineered to provide a design density of 0.10 gpm/ft over the listed coverage minimum design density of 0.10 gpm/ft over the listed area. Listed flows as specified by the manufacturer's coverage area. Listed flows as specified by the technical data sheets are to be used. Residential manufacturer's technical data sheets are to be used. sprinklers shall be installed in conformance with the Residential sprinklers shall be installed in conformance manufacturer's installation guidelines and the applicable with the manufacturer's installation guidelines and the installation standard. Where horizontal sidewall applicable installation standard. Sprinkler frame and residential sprinklers are installed under sloped ceilings deflector shall be of bronze frame construction having a having a pitch of up to [4/12] [8/121, the sprinklers shall 3/4" NPT thread. Water seal assembly shall consist of a be listed for such use.Sprinkler frame and deflector shall Teflon-coated Belleville spring washer and machined be of bronze frame construction having a'/2"NPT thread. cup with 3 mm glass bulb containing no plastic parts,and Water seal assembly shall consist of a Teflon-coated having a temperature rating of [1550F (680C)] [1750F Belleville spring washer and top-loaded extruded cup (790C)]. Sprinklers shall have a nominal K-factor of 7.6. with 3 mm glass bulb containing no plastic parts, and Standard finish: [Bronze] [Chrome-plated] [White having a temperature rating of [1550F (680C)] [1750F Polyester] [Special finish- specify]. Recessed (790C)]. Sprinklers shall have a nominal K-factor of 5.8. escutcheon assembly shall be a steel, two-piece Standard finish: [Bronze] [Chrome-plated] [White escutcheon [with '/z" adjustment (Model F2)] [with 3/4" Polyester][Special finish-specify].Residential horizontal adjustment(Model F1)][of push-on and thread off design sidewall sprinklers shall be Reliable Model F1 Res 58, with'/2" adjustment(Model FP)]. Standard finish shall be SIN R3513 (Bulletin 135). [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable[Model F1 Model F1 Res 44 & 58 Recessed Res 76 Recessed Pendent/F1] [Model F1 Res 76 Horizontal Sidewall Sprinkler Recessed Pendent/F21 [Model F1 Res 76 Recessed P Pendent/FP] SIN R7618 (Bulletin 135). Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed Model F1 Res 76 CCP Pendent (Concealed) horizontal sprinkler." Add: Recessed escutcheon Sprinklers shall be [cULus Listed] low flow residential assembly shall be a steel,two-piece escutcheon with Yz" concealed sprinklers engin eyed to provide a minimum adjustment (Model F2). Standard finish shall be design density of0.10gpm over the listed coverage area. [brass][bright chrome] [white painted] [Special finish- Listed flows as specified by the manufacturer's technical specify]. Residential recessed horizontal sidewall data sheets are to be used. Residential sprinklers shall be sprinklers shall be Reliable Model F1 Res 58/F2, SIN installed in conformance with the manufacturer's installation R3513(Bulletin 135). guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame Model F1 Res 76 Pendent construction having a 3/4"NPT thread. Water seal assembly Sprinklers shall be [cULus Listed] low flow residential shall consist of a Teflon-coated Belleville spring washer and pendent sprinklers engine red to provide a minimum Cover plate assembly shall consist of a brass machined cup with 3 mm glass bulb containing no plastic over listed coverage area. parts, and having a temperature rating r ss cover plat F (68 design density of 0.10 gpmp plate Listed flows as specified by the manufacturer's technical ass e data sheets are to be used. Residential sprinklers shall be and copper alloy retainer flange. Method attaching the installed in conformance with the manufacturer's installation cover plate to the sprinkler cup shall a push on and guidelines and the applicable installation standard. thread-off design allowing a /z cover plate adjustment. Cover plate temperature rating shall be 1350 F (57 C). A Sprinkler frame and deflector shall be of bronze frame plastic protective cap shall be provided and factory installed construction having a /4"NPT thread. Water seal assembly inside the sprinkler cup to protect the sprinkler from shall consist of a Teflon-coated Belleville spring washer and damage,which could occur during construction before the machined cup with 3 mm glass bulb containing no plastic cover plate is installed.Standard cover plate finish: [White] parts, and having a temperature rating of [1550F (680C)] [Custom Color-specify]. ]. Concealed pendent sprinklers [1750F(790C)]. Sprinklers shall have a nominal K-factor of shall be Reliable Model F1 Res 76 CCP,SIN R7618(Bulletin 7.6. Standard finish: [Bronze] [Chrome-plated] [White 135). Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). 11. Reliable , . . For Complete Protection • Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection • The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances,whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices Recycled labld (800)848-6051 Sales Fax ®Paper (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reiiablesp6nkler.com Internet Address EG.Printed in U.S.A.05/08 PM 9999970322 i uponof 1 FIRE PROTECTION SYSTEMS .,_ UPONOR RESIDENTIAL FIRE PROTECTION SYSTEM (FORMERLY AQUASAFE°) FLOW VERIFICATION TEST Flow Test ...................................................................................................................................................................................................................... Alliance Color of test orifice used: Member ID Manifold pressure reading Number: before test(static pressure): Company Name: Manifold pressure reading Contact: during test(residual pressure): Phone: Test gauge pressure on test connector before test(static pressure): Fax: Test gauge pressure on test connector Job Name: during test(residual pressure): Project Number: What time of day was the flow test taken? Job Address: How many gallons of water ran into the test bucket in 60 seconds? City: How many gallons of water did State,ZIP: the design predict as required? Did the test meet or exceed design flow? ❑Yes ❑No After completing this form, please fax it to the Uponor Fire Protection Design department Which sprinkler did you flow? Number: at(952)891-1115. Date left in service with all valves open: ...................................................................................................................................................................................................................... Test Witnessed and Verified by: Name Signature Occupation Date a 0 Additional Explanations and Notes 0 a a 0 �fYVj O Uponor,Inc. Tel:(800)321-4739 5925 148th Street West Fax:(952)891-1409 Apple Valley,MN 55124 Web:www.uponor-usa.com W' O� 5925 Valle Street West Apple Valley,MN 55124 Phone:800-321-4739 Ltfe, Safety, Comfort Systems Fax:952-891-1409 www.wirsbo.com Brass ProPEX Tee Submittal Information Component Project Information Job Name: Part No. Ordered: Location: Quantity Ordered: P.O. Number: Engineer: Date Submitted: Contractor: Submitted By: Mfg Rep: Approved By: Technical Data Material.............................................B140 Copper Alloy UNS C31400 _____________________________________________________or B16 Copper Alloy UNS C36000 �A Product Information and Application Use The brass ProPEX tees are available for use in hot and cold domestic potable water systems.These tees are also approved for use in any hydronic heating e and AQUAPEX plumbing systems. Each end of the tee is manufactured with the \ \� Wirsbo ProPEX fitting for connections to hePEX plus or AQUAPEX tubing. E 0 Ordering Information Dimensional Information �l Description Part Number A B C D E Weight [ ] Brass Tee, 1/2"PEX x 1/2"PEX x 1/2"PEX Q4705050 2.50" 1.45" 1/2" 1/2" 1/2" 0.20 Ibs [ ] Brass Tee, 3/4"PEX x 3/4"PEX x 3/4"PEX Q4707575 3.27" 1.90" 3/4" 3/4" 3/4" 0.20 Ibs [ ] Brass Tee, 1"PEX x 1"PEX x 1"PEX Q4701010 4.10" 2.45" 1" 1" 1" 0.40 Ibs Code Approvals/Standards Installation ANSI/NSF 14 and 61 certified • Use the appropriate PEX ring for the tubing being connected. ASTM F 877 • Refer to the Wirsbo AQUAPEX Installation Handbook for ASTM F 1960 additional information. CAN/CSA B137.5 ICBO ER 5142 IPC Related Applications UPC AQUAPEX—Hot and Cold Potable Water Distribution NSPC Wirsbo Radiant Floor Heating Systems SBCCI(PST and ESI Report No. 9661) Wirsbo Permafrost Heating Systems UL 1821 ('/z"X X '/2") Wirsbo Snow&Ice Melting Systems Bdnwg CO .;#! q O II I ©2002 Uponor Wirsbo Brass ProPEX Coupling Submittal—October 1, 2002 W'�� O® 5925 Valle Street West Apple Valley,MN 55124 Phone:800-321-4739 Ltfe, Safety, Comfort Systems Fax:952-891-1409 www.wirsbo.com ProPEXO Brass Reducing Tee Submittal Information Component Project Information Job Name: Part No. Ordered: Location: Quantity Ordered: P.O. Number: Engineer: Date Submitted: Contractor: Submitted By: Mfg Rep: Approved By: Technical Data Material------------------------_...................B140 Copper Alloy UNS C31400 ^ _____________________________________________________or B16 Copper Alloy UNS C36000 Product Information and Application Use ProPEX Brass Reducing Tees are available for use in hot and cold domestic potable water systems.These reducing tees are also �� �o B approved for use in any hydronic heating systems. Each end of the reducing tee is manufactured with the Wirsbo ProPEX fitting for �E connections to hePEX plus or AQUAPEX tubing. Ordering Information Dimensional Information �I Description Part Number A B C D E Weight [ ] Reducing Tee, 1/2"PEX x 1/2"PEX x 3/4" PEX Q4705575 2.80" 1.90" 1/2" 1/2" 3/4" 0.40 Ibs [ ] Reducing Tee,3/4"PEX x 1/2"PEX x 1/2" PEX Q4707555 3.05" 1.66" 3/4" 1/2" 1/2" 0.40 Ibs [ ] Reducing Tee,3/4"PEX x 1/2"PEX x 3/4" PEX Q4707557 3.05" 1.90" 3/4" 1/2" 3/4" 0.40 Ibs [ ] Reducing Tee,3/4"PEX x 3/4"PEX x 1/2" PEX Q4707550 3.27" 1.66" 3/4" 3/4" 1/2" 0.40 Ibs [ ] Reducing Tee,3/4"PEX x 3/4"PEX x 1"PEX Q4707710 3.62" 2.45" 3/4" 3/4" 1" 0.50 Ibs [ ] Reducing Tee, 1"PEX x 3/4"PEX x 3/4"PEX Q4701775 3.86" 2.20" 1" 3/4" 3/4" 0.30 Ibs [ ] Reducing Tee, 1"PEX x 3/4"PEX x 1"PEX Q4701751 3.86" 2.45" 1" 3/4" 1" 0.40 Ibs [ ] Reducing Tee, 1"PEX x 1"PEX x 1/2"PEX 04701150 4.10" 1.98" 1" 1" 1/2" 0.40 Ibs [ ] Reducing Tee, 1"PEX x 1"PEX x 3/4"PEX 04701175 4.10" 2.20" 1" 1" 3/4" 0.40 Ibs Code Approvals/Standards Installation ANSI/NSF 14 and 61 certified • Use the appropriate size PEX ring for the tubing being ASTM F 877 connected. ASTM F 1960 • Refer to the Wirsbo AQUAPEX Installation Handbook for CAN/CSA B137.5 additional information. ICBO ER 5142 IPC UPC Related Applications NSPC • AQUAPEX—Hot and Cold Potable Water Distribution SBCCI(PST and ESI Report No.9661) • Wirsbo Radiant Floor Heating Systems • Wirsbo Permafrost Heating Systems • Wirsbo Snow& Ice Melting Systems Bringing II I ©2003 Uponor Wirsbo ProPEX Brass Reducing Tee Submittal—December 1,2003 Wirsbo AQ UAPEX° Tubin9 - Lengths the uponof 9 Submittal Information Revision A: April 21, 2008 Project Information Job Name: Location: Part No.Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: Crosslinked polyethylene PEX-a Engel Method Standard Grade Hydrostatic 180OF(93 820C)at 80 psi Ratings(PPI): 12 F( C)at 100 psi 120°F(49°C)at 130 psi 73.4°F(23°C)at 160 psi Linear Expansion Rate: 1.10"/10°F(120C)/100' A B Product Information and Application Use Wirsbo AQUAPEX°'tubing is used primarily in hot and cold potable water distribution systems and AQUASAFE®Residential Fire Safety Systems. Note: Uponor's 1/2",3/4"and 1"Wirsbo AQUAPEX tubing is listed to UL 1821 and ULC/ORD C199P and carries an additional rating of 120°F(49°C)at 130 psi. Description Part Number A B Weight 1/2"Wirsbo AQUAPEX, 100-ft.coil F1040S00 0.469" 0.629" 6 lbs. 1/2"Wirsbo AQUAPEX, 300-ft.coil F1060500 0.469" 0.629" 19 lbs. 1/2"Wirsbo AQUAPEX, 1,000-ft.coil F1120500 0.469" 0.629" 58 lbs. 3/4"Wirsbo AQUAPEX tubing, 100-ft.coil F1040750 0.670" 0.875" 10 lbs. 3/4"Wirsbo AQUAPEX tubing,300-ft.coil F1060750 0.670" 0.875" 34 lbs. 3/4"Wirsbo AQUAPEX tubing,500-ft.coil F1100750 0.670" 0.875" 54 lbs. 1"Wirsbo AQUAPEX tubing, 100-ft.coil F1041000 0.860" 1.123" 21 lbs. 1"Wirsbo AQUAPEX tubing,300-ft.coil F1061000 0.860" 1.123" 58 lbs. 1"Wirsbo AQUAPEX tubing, 500-ft.coil F1101000 0.860" 1.123" 94 lbs. 11/4"Wirsbo AQUAPEX tubing, 100-ft.coil F1061250 1.069" 1.375" 35 lbs. 11/4"Wirsbo AQUAPEX tubing,300-ft.coil F1021250 1.069" 1.375 106 lbs. 11/2"Wirsbo AQUAPEX tubing, 100-ft.coil F1061500 1.263" 1.625" 44 lbs. 11/2"Wirsbo AQUAPEX tubing,300-ft.coil F1021500 1.263" 1.625" 133 lbs. 2"Wirsbo AQUAPEX tubing, 100-ft.coil F1062000 1.629" 2.125" 70 lbs. 2"Wirsbo AQUAPEX tubing,200-ft.coil F1052000 1.629" 2.125" 140 lbs. 2"Wirsbo AQUAPEX tubing, 300-ft.coil F1022000 1.629" 2.125" 210 lbs. Installation Refer to the AQUAPEX Professional Plumbing Installation Handbook or the AQUASAFE Network Installation Guide and Looped System Installation Guide for additional information. Standards CSA B137.5; ASTM F876; ASTM-E84; CAN/ULC 5102.2;ASTM-E119/UL 263 Codes IPC; UPC; NSPC; IRC; NPC of Canada Listings ANSI/NSF 14-and 61-certified; ICC ESR 1099; IAPMO 3558; PPI TR4;CSA; UL 1821; ULC/ORD C199P(1/2",3/4"and 1"Wirsbo AQUAPEX tubing); WARNOCK HERSEY 25 FS/50SD plenum listing; UL Fire Resistive Assemblies(K913,L557,V444, U372) Related Applications Contact Information PEX-a Plumbing Systems Uponor,Inc. Uponor Ltd. AQUASAFE Residential Fire Safety Systems 5925 148"Street West 655 Park Street Apple Valley,MN 55124 USA Regina,SK S4N 51\11 CANADA Phone: (800)321-4739 Phone: (888)994-7726 Fax: (952)891-2008 Fax: (800)638-9517 www.uponor-usa.com www.uponor.ca VIXR.GuideInfo - Cross-linked Polyethylene Sprinkler Pipe and Fittings Page 1 of I U` ONLINE CERTIFICATIONS DIRECTORY VIXR.GuideInfo Cross-linked Polyethylene Sprinkler Pipe and Fittings View ListiriQ5 -Page BgttQm [Sprinkler System and Water Spray System Devices] (Piping, Sprinkler System) Cross- linked Polyethylene Sprinkler Pipe and Fittings See General Information for Piping Sprinkler System Cross-linked polyethylene(PEX) pipe and fittings are intended for use in multipurpose piping systems of residential occupancies as defined in the Standard for Installation of Sprinkler Systems in One-and Two-Family Dwellings and Manufactured Homes, NFPA 13D. Protection shall be provided for PEX pipe and fittings.The minimum protection shall consist of either(1)one layer of 3/8 in. gypsum wallboard, (2)a suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs.per sq.ft.when installed with metallic support grids, (3) 1/2 in. plywood soffits,or(4)one layer of 1/2 in. plywood. During remodeling or ceiling repair,appropriate precautions shall be implemented to properly shield the piping from the protected occupancy. PEX pipe and fittings are intended to be installed in accordance with the requirements specified in the manufacturer's installation instructions and NFPA 13D. Special installation and design criteria relative to pipe hanger spacing, piping and sprinkler restraint,sprinkler temperature rating, piping location,testing procedures and friction loss characteristics are specified in the manufacturer's installation instructions provided with the pipe. PEX pipe and fittings are not intended to be installed in combustible concealed spaces where sprinklers are required by NFPA 13D. PEX pipe and fittings are intended for use in areas where the maximum ambient temperature does not exceed 120°F. If the ambient temperature is expected to exceed this limitation,refer to the manufacturer's installation instructions for additional information on methods to reduce the pipe exposure temperatures. These pipe and fittings are not intended to be installed in outdoor applications. The PEX pipe and fittings are intended for use in wet pipe systems only and have not been investigated for use in dry pipe systems. The manufacturer's installation instructions should be reviewed and Authorities Having Jurisdiction consulted before installation. The basic standard used to investigate products in this category is UL 1821,"Thermoplastic Sprinkler Pipe and Fittings for Fire Protection Service." The Listing Mark of Underwriters Laboratories Inc.on the smallest unit container in which the product is packaged with or without the UL symbol on the product is the only method provided by Underwriters Laboratories Inc.to identify products manufactured under its Listing and Follow-Up Service.The Listing Mark for these products includes the UL symbol, (as illustrated in the Introduction of this Directory),together with the word"LISTED,"a control number,and one of the following product names,as appropriate: "PEX Sprinkler Pipe"or"PEX Sprinkler Fitting". Last Updated on 2000-04-17 Questions? Notice of Disclaimer page Top Copyright_©20g7_1 nderw rile rs Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow- Up Service.Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.The Guide Information,Designs and/or Listings(files)must be presented in their entirety and in a non-misleading manner,without any manipulation of the data (or drawings).2.The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc."must appear adjacent to the extracted material.In addition,the reprinted material must include a copyright notice in the following format: "Copyright©2007 Underwriters Laboratories Inc.@" An independent organization working for a safer world with integrity, precision and knowledge. lr,�40) http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showp age.html?name=VIXR.GuideI... 9/5/2007 W'�� O� 5925 Valle Street West Apple Valley,MN 55124 Phone:800-321-4739 L fe, Safety, Comfort Systems Fax:952-891-1409 www.wirsbo.com Brass ProPEX Coupling Submittal Information Component Project Information Job Name: Part No. Ordered: Location: Quantity Ordered: P.O. Number: Engineer: Date Submitted: Contractor: Submitted By: Mfg Rep: Approved By. Technical Data Material___________________________________6140 Copper Alloy UNS C31400 A ____________________________________________or B16 Copper Alloy UNS C36000 Product Information and Application Use B The brass ProPEX fittings are available for use in hot and cold domestic potable water systems. Fittings are also approved for use in any hydronic heating and PEX fire suppression systems. Each end of the coupling is manufactured with the Wirsbo ProPEX fitting for connections p to hePEX plus or AQUAPEX tubing. Orderinq Information Dimensional Information �l Description Part Number A B C D E Weight [ ] Brass ProPEX Coupling, 3/8"PEX x 3/8"PEX Q4543838 1.31" 0.75" 3/8" 3/8" N/A 0.02 Ibs [ ] Brass ProPEX Coupling, 3/8"PEX x 1/2"PEX Q4543850 1.43" 0.84" 3/8" 1/2" N/A 0.02 Ibs [ ] Brass ProPEX Coupling, 1/2"PEX x 1/2"PEX Q4545050 1.54" 0.84" 1/2" 1/2" N/A 0.03 Ibs [ ] Brass ProPEX Coupling, 1/2"PEX x 3/4"PEX Q4545075 1.78" 1.19" 1/2" 3/4" N/A 0.04 Ibs [ ] Brass ProPEX Coupling, 3/4"PEX x 3/4" PEX Q4547575 2.00" 1.19" 3/4" 3/4" N/A 0.06 Ibs [ ] Brass ProPEX Coupling, 3/4"PEX x 1"PEX Q4547510 2.25" 1.35" 3/4" 1" N/A 0.10 Ibs [ ] Brass ProPEX Coupling, 1"PEX x 1"PEX Q4541010 2.50" 1.35" 1" 1" N/A 0.13 Ibs Code Approvals/Standards Installation ANSI/NSF 14 and 61 certified • Use the appropriate PEX ring for the tubing being connected. ASTM F 877 • Refer to the Wirsbo AQUAPEX Installation Handbook for ASTM F 1960 additional information. CAN/CSA 13137.5 ICBO ER 5142 I PC Related Applications UPC AQUAPEX—Hot and Cold Potable Water Distribution NSPC Wirsbo Radiant Floor Heating Systems SBCCI(PST and ESI Report No. 9661) Wirsbo Permafrost Heating Systems Wirsbo Snow&Ice Melting Systems Bnnwg O 11 I ©2002 Uponor Wirsbo Brass ProPEX Coupling Submittal—October 1,2002