Loading...
HomeMy WebLinkAboutBLD2017-00015 Additions - BLD Permit / Conditions - 3/15/2017 Inspection Line (360)427-7262 °pU.yTF MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County 615 W Alder St Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2017-00015 OWNER: HELICOPTER CONSULTANTS, INC RECEIVED: 1/9/2017 CONTRACTOR: LICENSE: EXP: ISSUED: 3/15/2017 SITE ADDRESS: 318 E UNION HEIGHTS DR UNION EXPIRES: 9/15/2017 PARCEL NUMBER: 322327590122 LEGAL DESCRIPTION: TR 12-B OF SURVEY 5/59 TR 3 OF SP#610 PROJECT DESCRIPTION: DIRECTIONS TO SITE: ADDITION TO EXISTING GARAGE, ADDING LIVING SPACE AND OUT E BROCKDALE RD TO E MCREAVY RD, FOLLOW E MCREAVY RD TO CARPORT UNION HEIGHTS DR IN UNION General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 1 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R3 Lot Size:54,810 Deck: 336 Type of Work: ADD Fire Dist.: 6 No. of Stories: 2 Occ. Load: Building:684 Garage-Attached 989 Valuation: $ 124,970.24 Building Height: Occ. Status: Seasonal Basement:684 Carport 560 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: S 34.0 Ft. Shoreline: Ft. Water Body: Rear: N 20.0 Ft. Slope: Ft. SEPA?: Unkn Model: Width: Ft. Side 1: E 20.0 Ft. Shoreline Desig.: bWtiApplicable Year: Serial No.: Side 2: W 111.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 2 Ventilation Fan 2 Plan Check Fee JBN 1/9/2017 $736.94 S220170000000( Lavatories 2 Exhaust Hood 1 Planning Review Fee JBN 1/9/2017 $205.00 S220170000000( Showers 2 Dryer Vent 1 EH Plan Review JBN 1/9/2017 $210.00 S2201700000001 Water Heaters 1 Furnace<100K 1 Building State Fee MPB 2/6/2017 $4.50 S1201700000001 Clothes Washer 1 Building Permit Fee MPB 2/6/2017 $ 1,133.75 S1201700000001 Kitchen Sink 1 Final Inspection Fee MPB 2/6/2017 $73.00 S1201700000001 Dishwasher 1 Mechanical Permit Fee MPB 2/6/2017 $67.50 S1201700000001 Hosebibs 2 Mechanical Base Fee MPB 2/6/2017 $28.50 S120170000000( Plumbing Permit Fee MPB 2/6/2017 $93.20 S120170000000( Plumbing Base Fee MPB 2/6/2017 $24.70 S120170000000( Total $2,577.09 BLD2017-00015 Please refer to the following pages for conditions of this permit. Page 1 of 7 CASE NOTES FOR BLD2017-00015 CONDITIONS FOR BLD2017-00015 1) Application acknowledges,) that the structure is only permitted for a use consistent with the current zoning of the parcel. Zoning is RR-5. X J�C� 7 2) Apprgved.per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X X GG�4 3) Prior to final approval, all upland areas disturbed or new y�y cr�ajied by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X /t G( /J 4) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800- �0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X K 5) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depa ment,prior to any further inspections being performed or approvals granted. X %4 4 6) Owner/Agent i responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 7) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or X removal of approved documents will result in failure of required building inspections. BLD2017-00015 Please refer to the following pages for conditions of this permit. Page 2 of 7 8) All replacement windows shall be installed per manufacturer's specifications and be flashed per IRC section R703.8. All installations shall meet requirements for guards per R613 and safety glazing per R308.4. WSEC requires a U-factor of.30 or less in all heated spaces. Existing, non-conforming, egress window openings are not required to be enlarged, but it is highly recommended. Egress windows replaced in an existing opening shall be brought into compliance with current codes if a product is available for this application. Building plans/permit are required for windows in new, enlarged or relocated openings these installations must meet all current codes. Windows and doors shall be installed in accordance with the manufacturer's written installation instructions and shall be available during inspections. X 9) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM STAB� �SI SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE. X /C 10) Single rafter joist roof reac nt shall be insulated to a minimum of R-38 allowing for a minimum of one-inch continuous vented airspace above the level of insulation. X 11) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Buildin zg Department prior to any further inspections being performed or approvals granted. X 12) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECC/WSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate" and are available in %or'/z sheets. The Mason County Permit Center will also have some available. X R a 13) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. x /Z �,7p BLD2017-00015 Please refer to the following pages for conditions of this permit. Page 3 of 7 14) WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. X 9 4�b ! 15) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. (I RC 2012 R905.2.8.5) X -� 16) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor s a owledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 17) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000. X R a_6 18) To perform an inspection the Mason County Building Inspector will need to access the interior of the structure. An electrical permit completed and approved by Washington State Labor& Industries must be available on-site during the inspection. The Mason County Building Inspector will inspect the following: Verify that the system is installed in accordance with manufacturer specifications-The inspector will check to make sure that the exterior unit is permanently installed and supported, the exterior unit complies with required setbacks to property lines, fuel tanks are located at least 10-ft from the system, a source of ignition,all exterior penetrations are properly sealed,condensate lines are installed and are properly supported, including proper material, slope, and that the condensate line terminates to a proper location outside of the foundation, copper refrigerant lines are insulated with '/2" thick continuous closed-cell foam insulation or better, indoor units are located at least 3-ft from smoke and carbon monoxide alarms,and that modifications made to the structure, to install the unit, does not affect existing structural members. X��� ' BLD2017-00015 Please refer to the following pages for conditions of this permit. Page 4 of 7 19) A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2015 IBC, Section 1705.12.2 • and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheet SLC designate wall(s) type SLC and SLC with fastener spacing 4 inches or less. • The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and sub�titted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. X 20) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. I EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. X `�) 21) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be X arged hall be collected by the Building Department prior to any further inspections being performed or approvals granted. 22) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in perm vocation. X BLD2017-00015 Please refer to the following pages for conditions of this permit. Page 5 of 7 23) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.2.2 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. X Q� 24) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org X k �2� 25) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or must be reviewed and approved by Mason County prior to construction. 26) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. x /Z C�( D BLD2017-00015 Please refer to the following pages for conditions of this permit. Page 6 of 7 27) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X 28) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X /2 29) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X ,�_, a 2) 30) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed. X R a�b - OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Signature Date t J,, 1 C "L a v Z OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) BLD2017-00015 Please refer to the following pages for conditions of this permit. Page 7 of 7 MASON RMIIT ASSIISTANCE O N MR NITY SERVICES Permit Noh&0/ /— 660 •BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL 615 W.Alder Street,Shelton,WA 98584 RECEIVED Phone Shelton:(360)427-9670 ext. 352•Fax:(360)427-7798 Phone 185 4 Belfair. (360)275-4467•Phone Elma:(360)482-5269 JAN 0 9 2017 BUILDING BUILDING PERMIT APPLICATION 615 W. Alder Street PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME �AM501 �� �'r NAME: MAILING AD RESS: MAILING ADDRESS: CITY:4))1 ln)j� STATE: ZIP: CITY: STATE: ZIP: PHONE#1: : pCob- gC,Ca PHONE: CELL: PHONE#2:T� EMAIL : EMAIL: L&I REG# EXP. PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER �j NAME Ylls?II' / �I(�,�11 P.� EMAIL S MAILING AEbRESS i CITY STATE Z PHONE 1 ELL PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 3 a�� --] — O as ZONING REC LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT SITE ADDRESS_3/6 ()hi&n Ro CITY jr DIRECTIONS TO SITE ADDRESS J IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWATER❑ LAKE ❑ RIVER/CREEK❑ POND ❑ WETLAND❑ SEASONAL RUNOFF ❑ STREAM❑ TYPE OF WORK: NEW ADDITION ® ALTERATION REPAIR❑ OTHER ❑ USE OF STRUCTURE esfdence, arage ommerclal Bldg,Etc. IS USE: PRIMARY ❑ SEASONAL ® NUMBER OF BEDROOMS_ NUMBER OF BATHROOMS HEATED STRUCTURE? YES(Whole Bldg) ❑ YES (Part(s)of Bldg NO ❑ n/ DESCRIBE WORK P 7 SQUARE FOOTAGE: (propose '-existing) 1 ST FLOG sq.ft. 2ND FLOORL� sq.ft. 3RD FLOOR sq.ft. BASEMENT sq. ft. DECK sq. ft. COVERED DECK J%2 sq.ft. STORAGE // sq. ft. OTHER sq. ft. GARAGI 4qa sq. ft. Attached il Delached❑ CARPORT ') sq. ft. Attached 11 Detached❑ MANUFACTURED HOME I *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENG WI BEDROOMS BATHS L'R ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC ® SEWER❑ / NEW ❑ EXISTING I PLUMBING IN STRUCTURE? YES N NO ❑ If yes, attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES ® NO❑ EXISTING SQ.FT. EXISTING BEDROOMS PROPOSED BEDROOMS 1 TOTAL BEDROOMS 1 OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT ,^,PE°LICP.TIrJN OF 180 Dr"YS .^.F "11CRE WILL CAUSE THE APPLICATION TO ESE EXPIRED. (MASON COUNTY CODE 14.08.42) X -7 Signature of OWN R(Must a signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH BUILD ING Boa` = MASON COUNTY COMMUNITY SERVICES �L�� I w0/.� P •�T�= Permit No: PERMI7A55ISTANCE CENTER: y •BUILDING•PLANNING•FIRE MARSHAL 615 W. Alder St-Shelton, WA 98584 B RECEIVED Y - - Phone Shelton:(360)427-9670 ext 352 Fax:(360)427-7798 U I�D I N G Phone Belfair. (360)275 4467 Phone Eima:(360)482-5269 O 9 2017 -�;4 .IAN B U I L D I N GLUMBING & MECHANICAL PERMIT APPLICATION 619 Wl Alder St d OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: NAME: MAILING ADDRESS: MAILING ADDRESS: CITY:LM jMQ STATE: zIP:!�g,5e? CITY: STATE: ZIP: PHONE: CELL: 2nd PHONE: EMAIL : EMAIL: L&I REG# EXP. PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):32� -7,--2 G -2OU a Zoning. R?—S LEGAL DESCRIPTION(Abbreviated): SITE ADDRESS: - CITY: (_)y2 ia� DIRECTIONS TO SITE ADDRESS: TYPE OF JOB NEW ADDS ALT / REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS— 1 sr FLOORS 2ND FLOOR_y_BASEMENT GAR-AriE ✓ OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPG Natural Gas Ductless_ Toilets a Type of Unit No. of Units Fees Bathroom Sink al Furnace Bath Tubs Heat Pump Showers a Spot Vent Fan Water Heater 1 Propane Tank Clothes Washer 1 Gas Outlets Kitchen Sinks J Wood/Gas/Pellet Stove Dishwasher ( Kitchen Exhaust Hood Hose bibs Z- Dryer Vent Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X //?/] Signature of A.pp nt Date X�m(,.Qt— I<t C ' P Owne Owners Representative Contractor _' Print Name (Circle one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Visit us on-line: http://www.co.masori.wa.us/community_dev/ Rev.1/27/2016 JBN Permit number BLD Mechanical Permit Checklist • Name of owner: Name of Installer: • Fuel Type? LPG Nat Gas Electric Other • If propane, what is the proposed size of tank(s)? • ',A hat tvpe of mechanical unit will be installed?(i.e.freestanding stove,forced air furnace, etc.) • If the unit is a wood stove,provide: Make Model Year Label Number • What is the use of the structure? (Circle one) Residential Commercial (A permit application for a commercial mechanical permit will be issued upon satisfactory review by staff. Include a floor plan showing the location of unit(s)and layout of duct work with the permit application.) • Type of structure: (Circle one) Site Built Home Manufactured Home Other • What room will the mechanical unit be located? • Will the unit be located in a basement?(circle one) Yes No • How will combustion air be supplied to the mechanical unit? (Describe, i.e. direct vent, air inlets, etc.) • How will the mechanical unit be exhausted to the outside? Applies to appliances using gas, oil or wood fuel. (Indicate B-vent, direct vent,L-vent,etc.) • What year was the structure constructed? Was this structure part of a PUD upgrade? • What type of controls will be installed? (i.e. thermostat, etc.) • Will the proposed mechanical unit be a heat source?(circle one) Yes No • Additional information: Signature of Applicant Date Typical mechanical fees: Forced air furnace $ 18.30 Heat pump 18.20 Propane tank 73..00 Gas Outlets 6.20 additional outlets over 1-5 ($1.20 each after 5) Mechanical base fee 28.50 or$ 9.00 if base fee was paid on an active building or mechanical permit Freestanding unit, fireplace, pellet stove or wood stove $73.00 Final Inspection fee 73.00 BUILDING Name kf r,i"-PY �� cal �o,,1fi5 Parcel# BLD#,:?017- Q/5 IVl C, Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page I of 2) Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of Stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings 4 X I _ X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = Parking Areas X Any paved,gravel or packed area per definition X above table X = Patios/Walks X 3t,o X = Any paved, gravel or packed area per definition above table X = Others X = w`l X If the total impervious area of the proposed site X = development.is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area(sum of all areas) ' If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. <— ?fi- Own /Agen ontractor(circle one)Date: / If the Total Impervious S1 rface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 DECEIVED 615 W. Alder Street Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a Stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout' PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone:360-427-9670 e)d 450 100 W.Public Works Dr Shelton.WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: 360-427-9670 ext 400 415 N. 6th St— Bldg#8 lower level Shelton. WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT e WSEC/Ventilation Code Compliance Application Submit with heating/cooling system size worksheet (see instructions #4) Owner: Parcel#: Type of project: 3aa - s-ctoIaa Total Sq. Ft. 1 Floor: 2" floor: Heated Basement: of heated area:: (a84 g L( Heating System Type: O Electric wall heater O Electric Central Furnace O LPG Furnace O Heat Pump with electric furnace O Heat pump with gas furnace 9 Ductless Heat Pump O Boiler, specify fuel type: O Other: Specify: ® Prescriptive Option Table R402.1.1 (see table on previous page) Compliance Method ❑ Component Performance, R402.1.3 — Calculation worksheets required Must Check one:: ❑ Other (Specify): Check one ® Whole House Ventilation system ❑ Whole House Ventilation using exhaust fans&window or wall Integrated with a Forced Air El Other, describe: Ventilatio fresh air vents (M1507.3.4). If using System (M1507.3.5) n System window vents be sure to order windows with vents. Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements," all residential units must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to comply. If the table is not attached to this form you can access the table on our website at: hftp://www.co.mason.wa.us/forms/Community Dev/iecc wsec.pdf Additional Description: Small dwelling units: less than 1,500 sq. feet of heated or cooled floor area and less than 300 sq. ft fenestration area (skylights, doors, windows, etc). Energy *Including additions to existing building that are greater than 500 sq. ft. of heated floor Efficiency Requirem but less than 1,500 sq ft of floor area. Requires 1.5 credits ents b) Medium dwelling units that are not included in (a) above {small dwelling), OR (c) below Energy {large dwelling) Requires 3.5 credits credits EXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2.5 required: credits. See page two for description. 1. 5 c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled floor area. Requires 4.5 credits d) Additions less than 500 sq feet. Requires .5 credits (Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque doors, lazed-doors that include products with glass and non-glass glazing materials. Describe Energy Credit Option(s):n Using Option number(s): RECEIVED JAN 0 9 2017 BUILDING 3 615 W. Alder Street FENESTRATION SCHEDULE USE FOR ENERGY CREDIT a) SMALL DWELLING OPTION & COMPONENT PERFORMANCE COMPLIANCE List all windows, doors, skylights (If needed. attach an additional sheet) 'Fenestration is defined in IECC Chapter 2 as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazing materials. Manufacturer Location U-Factor Size Quantity Total (rough opening) Square Feet Total Fenestration: windows, skylights and door area Energy Credits 4