HomeMy WebLinkAboutBLD2022-00732 Final MFG Home - BLD Inspections - 6/18/2024 MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584 COMMUNITY SERVICES SHELTON:360-427-9670,EXT 352 BELFAIR:360-275-4467,EXT 352 Buildin%Planning,Environmentalliealth,CommunityHealdi ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY`* To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection. Permit Number BLD2022-00732 Date Issued 08/12/2022 Iss By Project NEW MFG Site Address 50 NE Schooner Ct Applicant CUNNINGHAM JOHN HOWARD Contractor FUTURE HOMES OF BREMERTON Contractor Phone 1.360.479.4663 Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type MANUFACTURED HOME Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.— PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Department Building Official: Community Services Designee Concrete Setbacks Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home Ct-210-7,Z rT7— s'23 �J Concrete Foot/Runners q�Lto-ZZ J-I-L Final Other f t-e- ( s- rq 13 �a I' iF,.( Fa�C6-1 d a3 �� �FtrlcC fA(L.6-;-rr a3 ,P0 s" A-h'- MASON COUNTY 360-427-9670 Shelton ext.352 . COMMUNITY SERVICES 36 60-482-52 Belfairext.352 360-482-5269 Elma ext. 352 Building, Planning, Environmental Health,Community Health 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER: ADDRESS/LOCATION: sp A-) cr' St yvy n/ER C% FINDINGS: G C t f'C 7O 3E (.W OTC �'�.�i'ro'7 x�►te l ai..CS �uF -)o l� ►oac�� �-� ��c ros� ��,rkk�sy� sio 1 t 1 to� 6L �e•Q ; �¢ 1 k f- �c A� 1 44r- e-,-t o tO Q- Items listed above must be corrected to p_ain compliance. [1 THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. OK to Date: - - ❑ Please contact our office regarding possible Department: LD structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building, Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: &D20aa-GO-73e2 ADDRESS/LOCATION: S0 /UE 0C41QOA)E2 C.i FINDINGS: 4aS A0 62 En���•nui-�s � ��tLT� 7eo�. V oorck d .1 __/14SOA)Co cJNTYtj .a Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. OK to -5-wD S,y Date: 6 16',23 ❑ Please contact our office regarding possible Department: Bur) structural damage incurred by recent "natural/man made"disasters.This is NOT a Inspector: ,�� CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Belfair ext.352 360-482-5269 Elma ext.352 Building, Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER: FID20,22—60`73 a ADDRESS/LOCATION: SO /UE 5-01WA)EK FINDINGS: / D►not' COMI-4 s 4 '-o 6ockinj un,1t!e� Gka�c .GIo�C,� I rL n \j e-,Itj al-ov, c�, !K ora,W1 a-01U+110( C $ �� �=n ;.• vc� fir, D pJufts Wt r rCcci fO nmi eA-,kl I cLi4 ,T4V- CS,T ,r -k 44is 4a-iAkd lo� 6ef� Co,mc:A , J-)MRSOA/W MRJp4)C-00NTYQA•6dV Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. OK to Date: Please contact our office regarding possible Department: &D structural damage incurred by recent Inspector: .DCD "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 ` Mason County I Mason County - Division of Community Development 615 W. Alder St. Bldg.8 x�,vati'c� Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us B DD2022-00732 MANUFACTURED HOME PROJECT DESCRIPTION: NEW MFG ISSUED: 08/12/2022 SITE ADDRESS: 50 NE SCHOONER CT BELFAIR EXPIRES: 02/08/2023 PARCEL: 123305200035 APPLICANT: CUNNINGHAM JOHN HOWARD OWNER: CUNNINGHAM JOHN HOWARD 13639 COHO RUN NW 13639 COHO RUN NW BREMERTON,WA98312 BREMERTON,WA98312 360.440.5124 GENERAL CONTRACTOR'S LICENSE: FUTURE HOMES OF BREMERTON License: FUTURHB812JS 4021 W STATE HWY 15 Expires: 07/30/2023 BREMERTON,WA98312 1.360.479.4663 FEES: Paid Due Modular/Manufactured Home $275.00 $0.00 Fee-2nd half collected at ready to issue Technology Surcharge $11.00 $0.00 Planning Review Fee $240.00 $0.00 State Fee-Residential $6.50 $0.00 Modular/Manufactured Home $275.00 $0.00 Fee- 1 st half collected at submittal Building Plan Review/Change of $125.00 $0.00 Use- Onsite Sewage Totals : $932.50 $0.00 REQUIRED INSPECTIONS Setback Inspection Connection has been verified by Health or Utilities Footing Inspection BLD-Final Inspection Set-Up Inspection Printed by:Amber Selby on:08/12/2022 09:42 AM Page 1 of 5 Mason County Mason County - Division of Community Development ''�'��*• 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us MANUFACTURED HOME BLD2022-00732 CONDITIONS The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M. Support configuration shall be clearly marked in the installation instructions. * Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * REQUIRED INSPECTIONS (Footing Inspection-prior to pour(set-up manual must be on-site), Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the current fees adopted by the Mason County Building Dept., and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. Until resolution of any/all problems no occupancy (Final Inspection)will be granted for the residence. OWN ER/CONTRACTOR(indicate which) Printed by:Amber Selby on:08/12/2022 09:42 AM Page 2 of 5 Mason County X Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us MANUFACTURED HOME BLD2022-00732 " Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified installer responsible for each major part of the installation. RCW43-63B.090 An approved Installer cerification tag shall be placed on the end of the manufactured home directly above or below the HUD certification tag or temporarily located in plain site within three feet of the home's front entry. There shall be one certification tag for each certified installer accounting for the work that each installer performed or installed. Certification number and signature of the certified installer responsible for each major part of the installation. WAC365-210 * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American National Standards Institute (NCSBCS/ANSI A225.1). * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/age nt/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * This permit is for the placement and installation of the manufactured home only and does not imply approval or review for any other items indicated on the plot plan. Printed by:Amber Selby on:08/12/2022 09:42 AM Page 3 of 5 t Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us MANUFACTURED HOME BLD2022-00732 Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * All property lines shall be clearly identified at the time of foundation inspection. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B.) Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/ Perimeter Drains within 30ft, down gradient of Drainfield/ Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. * PLANNING SETBACKS Front: 25', Rear: 20', Side: 10' Measured from furthest projection Subject to EH Setbacks * Approval for residence only Printed by:Amber Selby on:08/12/2022 09:42 AM Page 4 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 ,uava� Shelton, WA 98584 360-427-9670 ext 352 www.co.masonma.us MANUFACTURED HOME BLD2022-00732 I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and (Irdinances gov rning this type of work will be complied with whether specified4hereint. The granting �rmit does not presume to give authority to violate or cancel the proviof r state/lo al I r gulating construction or the performance of construction. Issued B Contractor or Authorized Agent: Date: r�� Printed by:Amber Selby on:08/12/2022 09:42 AM Page 5 of 5 NN►NG RECEIVED e?L�D� -�7�� LA JUN - 8 2uzz 15 W. (\AeLCCetACLI 10'-f' !'-7 1 1• 1'-9 1 I• 11'-! 1//• 6-5 I/4' t'-/• 6'-1• 1-( IMTCN ant A-.Is A(3) amns tiH-Ei.x, CL OOFr 1 NLtKtu7i T sAwRo3uT AAi GAaMtHB 13 pD^ti CAM CILTVAL uTN 2 QI, t art an ID n MTM 1 fTV OIMIM6 LH UiNo FLU OALSCL47 LIGRT 108.7 rot KITCHEN O.T D C:T GtOq 1Li LL t D Il, a - RLC6fr'CD t 11NMT rye :ftAto C W,nu i���y�1OR +r 41,IW�cC roR / �Y L rater 60i t 'ILI UTILt 'ICEOtT fl �� Q SOUR SUai r ncmr 0 \ ii�IIstc Port 11 Oft mu ORPRu CftD 1 RAC RLtux:AIR a GRILL ® M LAD WI77LR a, ®•,L — TMy 76mR MISTER C!• J I ® tfrZ NWC f I _®� C tQJ WALL-HOomo, 1 RS6IISLR / 1 (2) att ��` .tso6t-om !A?CCiFOR M4 / / 0 a s7'-0 l/0• `f + ♦ ♦ /(//'-�Y��}} 1 WhTSON .( / OPT. /' DORMSR /�} ` atT Nru i \-/EO PFCAT roar Uin t Opt LRICE CQ tql TQQ SRLARNµL •�a'�Ly `{z / / fMet 101 TAN K 1 0rt / /i✓ t // uYiNG ROCH TV a4.1 daf Q ISO r. S6"-0• .215.0 ® 160 L 56'-0• Caveo TI67f61 °aP Ii•3783 WSW HB OaNt.TU.A,OrC• WOODBURN n._n. 210 56'-0• WAUR auC EAGLE 1) Opt glam bath per pcd(omit one sink) 2)Opt Bed#4 per pcd 28563s 3)Sliding glass door NDTLs: wT, 1. At Err SRALL It02 LL INSTALLED NtTHLN 30-Y. TIR/AHWER SFACL. 4)Opt Utility door with wall per pcd 2. wLCTR1W MALL PLATES-ALL NOT at INSTALILD irrrIEN or A OPT FLOOR PLAN RARGE Dot COOLT01. ]. ROOM TITLES INCLDDItlG III INDICATES SQUARE t00TAOE HAS StEAI CoRDIAED tort 0W1tiM6/TEN7I06 REQUIREMENTS. DIAW N,., !. Tilt MA2IMOM TRAVEL OIS7ANCL FA011 ART a'DRooM DOORWAY To AN NI] John G. ENTRY DOOR 13 27.t Li. MIX: 11/1S/20 THIS FLOOR FLAN AND ATTACHED Orrion DETAILS IIf ArfLIC:RRLEt 5. COMSINATIOR CC DETLCTOA/SHOMC ALARX eta r IS DESIGNED TO MLCT THEtOLLONIMG ENCNT3: IDANItst Grt1 fN YI RD zore lsH 1 Roof Lo III st 20 ills. PERIMETER PIERING REQUIRED HvnoN Fp.2 F It9].7 IILGI0567s PI$OSA16es H.document If Cumni as at 00,02=21 PLANNING 2 4 L L G C N O RCCEPTACyB NOTE: 'YLA1 TyFH art r2cC'T MLt:TArE OFC RLLER O TxcRNOSTAT I.. CONLINATION CO OLTLCTOR/ SMOKE ALARM Ot/UNCIBPtD6 Of C.00R OII UNDERs10E 0/ $IOXE ALARH xIY11IX 2'Of 1GY[A xITMIN I'OP NAffl .9ND1.2 RN I, i'OR BOB PONT POST LOfATI0p5, WL'THE APPLICAHLL SUPPLY IIX.LI'- '.SUPPLT WLLT CONSINATIOU OP fLOOR PLAX AND OPT. HIM.. NLliSe sUAt, , 0'.b r wn LO•DLTSM11 ra N R Ayl�cxTeIA�T9e[ BATH Q, FLUOR65`CGNT LIGHT OPT n IO'-1• !'-7 1 I• f'-11 1/I" s R A?qz' , Y ®L%70.9sT.[AN }..� .PANEL BOX 1 9TILIT7 a sow Tual rlfSlSL I .i F 0 AIB. OR D'lIDpt O-KW OR II•RLTYAR Y [i1N f saw _ N' µR [u•n bEDR07H S —� ,i 1I •-L: RAG AETURO AIR 311.7 aef ^A GRILLE K-NIRE A eWT a ('1 D;U On ZAP fOB PA {y L7 a IRG IN cm 1-9:,ac[ ALGI.TLR `�, r O. FLOOR REarsTER. -\ \ ®Nu1-NDUNTCD u"�'Rm�� OPT. G:LAMOUR BATH OPT. UTILITY WALL //� II�� Ivor Sam \ ®1� 1 PI ((((((�///�yyyyy'�````���� 4GOcATIOH R 4 outt"T POST LA T i1 =001E II - flJHEARNALL 11 , ..0 Qf I G[I _ __ IT C u fW7,ROD eaLi 1' i � f � ` TOe Xf2Lww FLAT LL W M. ' 6 ron F"ALO RECEIVED V avco AoOf iLAD 11 nA AryI,ICAILL � �N�r 1UOCAW wor'14A0 (sce. x III ' t� Jp OR ]Z•-L 1 s• a+DoaT.m.ANcr A ®!O a OPT. L• DOAHLR a `�.��� I �J -i c"rzRI A LRAM o J U N — 8 2022 HOoo>3 11 roR rAR 4�DR i el Ar 210 , ors �i� y6[[ OR Nlf1 L HEIL� '�!' / Mrt+I4R NMI CAN �rT a ` 0FT k1.0.0 1 bf..E 1 �i// LTYINO AOdt IHse'L eyt. rDe.FM 615 W. Alder Street EAGLE �py 28563S 1701f5! T]0595P ' 411NN! Ti?Sfi5 OF-1 m.T,TLI minF mAAF -Im FLOOR PLAN 10'-0" 30•-P' 1 '-s• 15'--O• OPTIONS OM1R1 BY, 2 .i a A13 JDhn G. 9-s• Ain •r ,.,a.,w,. OcrA, 06/0.9/21 uuOemaN 'R di' OPT . 4 TH ', , ROOM YAIII FP0.1 F 11 EG2e5679 PF8 OM19l3 0*00cumeN b U nnl Bs 6fOHN91203, CY tcmogsAAOEawPllEsr PLANNING: (�tpacaa-007ba Designer's Stamp Aarum smrmvnrtwwm�nw tea+*^+'+rs�n'a"" P"n"smm""� ALL SETBACKS ARE MEASURED FROM oTukaaix CarnrxwckmuwcNKawaugcr:rmrooac.LlMmiv brannun�xatn.�nrsasAEsaw.wrryr..o�arau�caeemsccr.,ra� THE FURTHEST PROJECTION OF THE a,,a, w,Aa•tia„a�mt.�w�x»�.re� BUILDING PLANNING SETBACKS PKSCRIPTNER0WM lMMEASJRts Front:25' r cmrt4n¢.w�aw.ww�w'ro.mwe,uvnwr.+awuw:,wun+n.•o Rear:20' ^ fi trxtmanevnWaramlo-:rnAr¢awrsrmcunvmnw.uncr„rsmn Ct anu+owurmEcae:neouurwv miommw.rt.wi+inu�. Side:10' n Ev axRRovERlTaSas Subject to EH Setbacks urru*rcwxruwvnanewawia;vrmm.vvA v¢cnmuutaa>t.+ �' '`.. APPROVED A^.QAetrnfpYmMlaxllWXNAa:m.vnmwamwAam..' amgrJanT ® °/a2,T w sa:aeaxrmanrrv�.cea� MASON COUNTY DOB PLANNING ' SITE PLAN REQUIRED TO BE ON SITE 11NSISNOTASURVEY CHANGES SUBJECT TO APPROVAL YI[aAl W urwum.uwlMsetoaxwtea.+NAoowAtv¢5rv+w wsw.]ciM aw.twmw[a.mnurecnaunAwe.scnuuw�+vrnmmaalai�m•:x By: Dat¢'07/06/2022 AUMtGiWLn"Il(FM:Ia�AIaSnRY.6IdLA.aM1�ntaM¢u9MO4aY.atvtD . Mtya�,y,•N.t1YDS1e w1014avS4 V.FmfaappgSA49tI0f11lS4OR4u!f%'IX:S Note:Approval for residence only County Review e EH Setbacks ,, �► A.)Drairf"Reseme requires 10'setback from toottngRoundalions • 1 8.)Septic tanks)requlras 5'setback tram all footingloundatbM - C.)Nd totmdaliom4 e&imeler Drains wdhin 3(Ht.downgrade l of • - - - t,9 Drat nfielyEteserw?area S No Cut Banks)(greater Lhan 511 over 45 degrees)within 50h N� APPROVED P P O Y j�`L D down gradterd of Drainneld?Resewerve araa A� •per a 0.s h 1 .OhtdSaRA�H�` EH APPROVED ' ryCO tYc Rhonda Thompson 07/07/2022 t. C) t9 SCALE, 0 15 ° A+Onsk LLC c�.u►aYertslficgllirp �m r.mtak.a. 0:wre Narre:Jft curittir w C. ADD cR'S3:50189dga1alx >t � 9ed'n,'MA9l5!! 12330.5200075 & OirpBl StnTissim 6>tr 11A7R021 W.A�n�ion Da�lA'1�P2 Name Parcel#�`d �^ �_ �15 BLD#VECCEIVED �ao�—QD73GC Mason County BUILDING Department of Community Development ,JUN - 8 2022 Small Parcel Stormwater Management Application/Workshsgt (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area All dimensions in feet Buildings X X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways Q X X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) /l ,� If the 'I'otal Impervious Surface Area is LESS THAN 2000 Sotiare Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described ope for view and inspec ion as may be required. X w gent/Contractor(circle one)Date:,�`��� f the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Pagel of 2 MASON COUNTY COMMUNITY SERVICES Permit N - L,020=-0073a PERMIT ASSISTANCE CENTER: R CE�VE •BUILDING•PLANNING•PUBLIC HEALTH.FIRE MARSHAL ■ E 615 W.Alder Street,Shelton,WA 98584 JUN - 8 2022 Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone Belfair(360)275-4467•Phone Elma:(360)482-5269 615 W. Alder Street BUILDING PERMIT APPLICATION PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: — NAME:�IfAf t�l/sU,�l NAME: MAILINGAODDIRESS: MAILING ADDRESS:_ /��f�j! CITY:_/g,-G�, X' j,�l STATE: ZIP: �CITY:,ot- 97ej?� STATE: A ZIP:4 %Z PHONE#1:�36p..- 72y PHONE: �� �ELL: PHONE#2: EMAIL : �� EMAIL: L&I RE EXP. PRIMARY CONTACT: OWNER[ram CONTRACTOR❑ OTHER❑ NAME / EMAIL MAILING ADDRESS CITY Ai�'��s-�./STATE ZIP PHONE CELLT��� T��Z�� 4= PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) ZONING LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT SITE ADDRESS �'- CITY�/�� �f s-- 01RECTIONS TO SITE ADDRESS gjy,6f,2 S THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO J5— IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWATER ❑ LAKE ❑ RIVER/CREEK❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM ❑ TYPE OF WORK: NEW gr ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.) jj10 Ad*g..�e-tom IS USE: PRIMARY 2-- SEASONAL ❑ NUMBER OF BEDROOMS_ NUMBER OF BATHROOMS_ HEATED STRUCTURE? YES(Whole Bldg) 93-' YES(Part[,,]of Bldg) El No ❑ DESCRIBE WORK L 44gL;- P s!!J. SQUARE FOOTAGE: (proposed) 1ST FLOOR l�sq. ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq. ft. DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE t6 90&� MODEL eZ;gr4 YEAR-Z LENGTH WIDTH BEDROOMS BATHS .2+ SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC 91"', SEWER ❑ / NEW 910' EXISTING ❑ PLUMBING IN STRUCTURE? YES P NO ❑ Ifyes, attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES ❑ NOff' EXISTING SQ.FT. EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS- ,g — OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.1 declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON COUNTY CODE 14.08.42) ignature of OWNE st be signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH 01,0022-(073a BUILDING RECE1v/E0 Mason County _ g NU Community Services-Building Division �UN MANUFACTURED HOME PLAN REVIEW SPECIFICATION505 W• A►der Street UNIT INFORMATION: Snow Load v Make fL1��t Model Year 2 Square feet Width �ly/7 Length ❑Single/Double/❑Triple-Wide (indicate) [ NEW or❑Replacement(indicate) All footings must be min. 12" below grade within 24"of the skirting when perimeter blocking is required. When manufacture specification is not available use ANSI A225.1 or HUD 24 CFR 3285. Must provide pier plan with reference sections. Allowable Pressure(Pound Per Square Foot)No Allowances made for overburden pressure,embedment depth,water table height,or settlement problems Soil bearing is assumed at 1500 psi If set-up is using a greater soil bearing capacity a soil report from a design professional is required Fill(compact or uncompacted) Compaction Report required through Special analysis Peat or organic clays Compaction Report required through Special analysis SET UP SPECIFICATIONS: Ef Manufacturer's Pier Plan ❑ ANSI A225.1/HUD24 CFR part 3285 FOUNDATION: Check the type of foundation and attach detail plans from manufacturer's or the ANSI A225.1/ HUD24 CFR part 3285 ❑ Pads Continuous concrete footing(runners) ❑ Slab ANCHORING: ❑ Ground ❑ Magnum ❑ Concrete-2500 PSI ❑ 1-bolt ❑ Expansion bolt For new units, this information can be obtained from the home retailer or contractor. Previously owned units,which manufacture's instruction are not available must utilize the ANSI A 225.1/ HUD24 CFR part 3285 code for installation. Washington State law requires that a certified installer install manufactured homes. The undersigned I hereby acknowledge he/she does understand that the Mason County submittal and review processes will be based on the information provided herein and will be verified at time of inspectic X Applicant/❑Dealer/❑Installer(indicate) Date -