Loading...
HomeMy WebLinkAboutBLD2008-00183 SFR and Garage - BLD Permit / Conditions - 3/12/2008 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 i� RESIDENTIAL BUILDING PERMIT BLD2008-00183 OWNER: JEFFREY ARAUJO RECEIVED: 2/19/2008 CONTRACTOR: J FIVE CONSTRUCTION LICENSE: JFIVECRO22JF EXP: 4/29/2008 ISSUED: 3/12/2008 SITE ADDRESS: 331 E UNION HEIGHTS DR UNION EXPIRES: 9/12/2008 PARCEL NUMBER: 322327590103 LEGAL DESCRIPTION: TR 10-C OF SURV 5/59 TR 3 OF SP#2231 #555474 PROJECT DESCRIPTION: DIRECTIONS TO SITE: SFR/Garage. 1 st paved road past Texaco up Union Heights Dr. follow to top past dark green house#281 on left. Next left on un named gravel easement road lot on right with Araujo sign. General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 1 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 1 Occ. Group: R3/U Lot Size: Deck: Type of Work: NEW Fire Dist.: 6 No. of Stories: 1 Occ. Load: Building:486 Garage-Attached 594 Valuation: Building Height: Occ. Status: Seasonal Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: E 80.0 Ft. Shoreline: Ft. Water Body: Rear: W 40.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Shoreline Desig.: Side 1: N 168.0 Ft. Year: Serial No.: Side 2: S 20.0 Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Hosebibs 2 Exhaust Hood 1 Plan Check Fee KKK 2/19/2008 $463.94 S22008000 Kitchen Sink 1 Ventilation Fan 1 Planning Review Fee KKK 2/19/2008 $190.00 S22008000 Lavatories 1 Dryer Vent 1 Address Fee BLF 2/21/2008 $162.00 S22o08bbo Showers 1 Fire Warden Review DHS 2/25/2008 $68.00 S22008000 Water Closets (Toilets) 1 ADJUST--Plan Check Fee MAL 2/27/2008 -$27.30 S22008000 Water Heaters 1 Building State Fee MAL 2/27/2008 $4.50 S22008000 Building Permit Fee MAL 2/27/2008 $671.75 S22008000 Mechanical Base Fee MAL 2/27/2008 $26.60 S22008000 Mechanical Fee MAL 2/27/2008 $29.15 S22008000 Plumbing Base Fee MAL 2/27/2008 $23.10 S22008000 Plumbing Fee MAL 2/27/2008 $47.11 S22008000 EH Plan Review TAM 3/10/2008 $100.00 S22008000 Total $1,758.85 BLD2008-00183 Please referto the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2008-00183 CONDITIONS FOR BLD2008-00183 1) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X 2) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X ; 3) PE /TITLE 14 MASON COUNTY BUILDING CODE -CHAPTER 14.17, STANDARDS FOR FIRE APPARATUS ACCESS ROADS- 14.17.110: A fire apparatus access road in excess of 14% grade and more than 150'to new residential or commercial structures will require an automatic fire sprinkler system installed. Contact the Mason County Fire Marshal at(360)427-9670, extension 273, for further information. x 4) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "A rov d Site Plan"to ensure these structures are shown and meet the setback conditions listed. X e- 5) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 6) Water yality is not to be degraded to the detriment of the aquatic environment as a result of this project. X BLD2008-00183 Please referto the following pages for conditions of this permit. 2 of 5 7) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647 0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 8) Approyed per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 9) Temporary erosion control measures must be implemented to prevent water quality,degradation of adjacent waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established. X Y ` 10) Application acknowledges that the structure is only permitted for a use consistent with the current zoning of the parcel. Zoning is Rural Residential 5. Maxirr)urn of one principal residence per 5 acres and one accessory dwelling unit per parcel as approved through a Special Use Permit. X 11, 11) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Departmetr prior to any further inspections being performed or approvals granted. X 12) Owner/, ent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X , C, 13) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official.•The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or remove of approved documents will result in failure of required building inspections. X 17 14) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 15) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building pppartment prior to any further inspections being performed or approvals granted. �� 16) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window(Max U-Factor):0.35, Skylight(Max U-Factor):0.58, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab Insulation R-10. Exception: R-30 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the undersid of the roof sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation. X � BLD2008-00183 Please referto the following pages for conditions of this permit. 3 of 5 17) Per 2003 IRC -SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. X e 18) Per 2003 IRC-SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordapce with the applicable provisions of this section and the manufacturer's installation instructions. X 19) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. `NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor�s acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X i 20) The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 21) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 22) Installation of heating equipment in single family residences shall meet the requirements of the current Washington State Energy Code. The furnace to be installed shall not exceed 150% of the heating and cooling design load. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted engineering practice, including infiltration and ventilation. Design calculations shall be available for inspection during the framing inspection. Warm-air furnaces shall have a minimum efficiency of 78%AFUE or higher or 80% combustion efficiency. All ducts shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems or tapes installed in accordance with manufacturers installation instructions. Duct tape is NOT permitted as a sealant on any ducts. Ducts in unheated spaces shall be insulated to R-8. X , 23) Placemen of structure must comply with standards set forth per the international codes regarding descending and/or ascending slopes. X 24) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinanoe or regulation, must be reviewed and approved by Mason County prior to construction. X " BLD2008-00183 Please referto the following pages for conditions of this permit. 4 Of 5 25) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED • BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 26) All property lines shall be clearly identified at the time of foundation inspection. X 27) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason,gounty ordinances and building regulations. X 28) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder h ve prevented action from being taken. No more than one extension may be granted. X 29) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 30) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 31) Please note: A separate permit is needed for the fire suppression system on this structure, as required by the Mason County Fire Marshal's office. Please be advised that the Fire Marshal's office needs to complete the fire suppression system inspection prior to the framing inspection request. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for revie d inspection. OWNERORAGENT: DATE: BLD2008-00183 Please refer to the following pages for conditions of this permit. 5 of 5 o CONCRETE MECHANICAL MANUFACTURED HOME Footings 1 Setbacks Date 3�?Iu`l By ►-, Ribbons ! C Gas Piping C— CD Interior Date By Interior-Date By Date By O Co Exterior Hate 14 of5' By Exterior-Date B w S*t'up �- I NS U LATI ON Point Load!Isolated Footings Date By n BG 1 SLAB INSULATION - - TI Date By Data By FIRE DEPARTMENT X Foundation walls Floors Date By < Date By Data 17 G By DECKS FRAMING walla Date By Date JZ41 By L Data Z By 1 PROPANE TANKS PLUMBING vault Data BY�_. Date By OTHER Groundwork Attic Date BY r Date 5f, 71 It By Type' - - Date By D.w.v DRYWALL Type- Int Brace wall Date By W Oats ^ o • BY Date BY FINAL INSPECTION CD water Line Fire Seperation IV w Date l i b By Wit Data By Date � 2�� Bye oc-,- m , co Pass or Request Inspect. c s Type of Insp. Fail Date Date Done By Comments o o rp�-1i W 6CD 81 boCD � v �ubS ►t u, �� I bIS L�� 8 a 0 E, U) A %wu �— 3 - a. �� Ind' O-Yt t 3a i� 3( DS� viLL ca-Nr•�- -rev- �.0 +k•.�e_ &BAP— 1 vo '04 1213 1 1 Of' A441, 3 7 04 0 ACCESS & GRADE INSPECTION PERMIT #04 ,24�CE—Col ADDRESS INSPECTOR —DATE./ 2-) 0�5- DRIVEWAY AC�ESS A Length: lrp Width: Z- Surface: Size of turn-around: Condition of shoulders: Vertical clearance: '--� need ost at end of drivewa wit reflective add ss numbers. 0-17 GRADE,OF DRIVEWAY % OF ROAD ROAD ACCESS Length: 2-0-0 Width: 2 Surface: Condition of shoulders: Vertical clearance: ( ) BURN PERMIT REQUIRED FOR LAND CLEARING FIRE. ( ) LOT INSIDE SMZ, 4X4 FIRES ONLY. ( ) LOT INSIDE UGA, NO OUTDOOR BURNING PERMITTED. LOT TOO SMALL FOR: BURN PERMITS 4X4 FIRES 2x3 FIRES. REMARKS KA5-7 continue remarks on back MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT FIRE MARSHAL Mason County Bldg. III, 426 West Cedar Street 1 PO Box 186, Shelton, WA 98584 Shelton (360) 427-9670 Belfair (360) 275-4467 Elma (360) 482-5269 On the web: http://www.co.mason.wa.us February 25, 2008 JEFFREY ARAUJO 81 E 2ND ST UNION WA 98592 Permit Number: BLD2008-00183 Parcel No.: 322327590103 Dear Applicant, A representative of the Mason County Fire Marshal's office conducted an inspection of the parcel referenced above to verify compliance to Mason County Building Code, Chapter 14.17 Standards for Fire Apparatus Access Roads. A copy of the standards and addressing guidelines referenced in the standards are enclosed. PLAN REVIEW REQUIREMENT COMMENTS: 1 . During the inspection the Fire Warden found that the access road does not comply with Section 14.17.110 that reads as follows: "A fire apparatus access road which is newly constructed or existing, and which is in excess of 14% grade, and which is greater than 150-ft from a primary access point intersecting with a County or State road right of way, to new residential or commercial construction will require an automatic fire sprinkler to be installed." A condition concerning the required fire sprinkler system will be placed on the building permit referenced above. A separate permit shall be required and approved. In addition the Fire Marshal's office shall complete the fire sprinkler inspection prior to the framing inspection request. If you have questions please contact the Mason County Fire Warden's office at (360) 427-9670 ext. 459. Denny Skinner Fire Warden Mason County Department of Community Development Encl.: Title 14 Mason County Building Code, Chapter 14.17 Standards for Fire Apparatus Access Roads Address Posting Requirements Guidelines for Private Road Signing Comments: 2/25/2008 1 of 1 BLD2008-00183 Request To Revise An'App roved Plan Permit Number: BLD200 - (j Name `,-A�eC 99 J V-Q LA ,ro Parcel Number 2232_ ne Number da time �) Project Address Mailing Address En ' nn 7C)Q- ` Please p vide a complete, detaikd description of the proposed revisions to the approved plans: Are two sets of the revised plans or addendum indicating the changes included? /11� Yes ❑ No Are the approved site plans included? ❑ Yes �<No Are the revisions clearly and accurately identified on the plans or addendum? A(Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? ❑ Yes JtC No If Yes,Has the engineer or architect approved this revision? ❑ Yes o No Is a stamped and signed approval included with this request? ❑ Yes ❑ No (Note:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record.) Does the proposed revision modify the footprint or location of the structure? Yes ❑ No If Yes, Is a revised site plan,with all new setback dimensions included with this request? ❑ Yes ❑ No Additional Information: Applicant's signa Da et . Office Use Only R ceived by: Date Sent Assigned To Approved By D to Original Valuation: $ VAL, G *9/0? Additional Valuation: $ ' 11 Sq.Ft. g Z x$��}.05 $ Sq.Ft. x$ $ Total New Valuation $ ❑ P.W. W Additional Fees: Additional Planning Dept. $ Additional Plan Review $ Z� f Additional Conditions/Comments: Additional Building Permit $ B4' Additional Plumbing $ Additional Mechanical $ Additional E.H.Dept. $ Other $ Total Amount Due: $ Amount To Be Paid Up-Front$ MASON COUNTY PERMIT NO*LJ`Da Z BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 I Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner Company Name j"j- r,'�e �ti..sr -t 1Z��.�►, Mailing Address S Mailing Address $ / E City UAJ, 0-sJ StateSAIA Zip Code 9 V 919 2, City_UN;Q,1J State Zip Code !?%-r9-2 Phone 31-0 -- X 9 51-i 1�'rhther Ph36c,-WO 1s'-) S Phone 36 y- X 2,V -..g,2 -7 fye Other Ph. V2 ci -a 1 `-. Lien/Title Holder Contractor Reg. z - Exp._$6 -A? - a E mail address T ARAcA .y 0 We Tc • coon, E Mail Address''AR.4 c_A i ej Ik rc. Ca," Drivers Lic.# DOB ' - Drivers Lic.#VAAAcd j, j S,/dp47 DOB -� - SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic__ Existing Septic " 3 Connect to Water System _1 Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATIQ 12 Digit PcelN �= _Fire District Legal Description fz Ac"-C S''c' 1/ S'%Jr� 7"q 3 old . 1 2� 3/` �.SS'S'�l�f� ' Site Address (Please include street name, street wiiioer and city)_. � I Directions to site7Xeje t 2&ja.'c _?z e:,0Q= 6 4_ 4-y c ads Will timber be cut and sold in parcel preparation?Yes CNI Is property within 200' of Saltwater tJ'j Lake G-' River/Creek N o Pond v Wetland Seasonal Runoff o Stream � Slopes or Bluffs > 15% 7 Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/Na TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building " ��K�; Describe Work!=�� ��► i 1 `�cLc ?�'7 No. of Bedrooms___ —No. of Bathrooms Square Footage- 1 st Floor ' 2nd Floor 3rd Floor -Basement '4 Deck= "" Covered Deck Other Sq. ft. Garage Attached ,v —Detached Carport Attached Detached MAN FACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No,of Bathrooms Type of Heat Purchase Price$ Rlm��t Unit? Yes/ No Installer Name ertification No. OWNER/BUILDER AcknovVIedges scbmission of inaccurate information may result in a stop work order or permit revocation. Acknowledgeryre4 of-&uch isby signature below. I declare that I am the owner,owners legal representative, or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the informaticn provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OFAPROGRE S INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X At Date: 2 - - u ' Owwer/Owners Repr entative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW AFAPROVO I Dr DENIED NOTES Building Department Ob Planning Department -7 Environmental Health Department !0 - U) _73- Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee eJ- EH Review Fee Plumbing & Base Fee 7 Planninq Review Fee Mechanical & Base fee i Other Wood /Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ � TOTAL FEES 2J MASON COUNTY PERMIT NO. PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair(360) 275-4467• Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner -r,'7Q#&C U 10 Company Name?"fe4ha Mailing Add ress_tl Mailing Address 21 E " ^�zt city U'Ou PnAj State1,&Zip Code City cj"' t,,J State-&-'A Zip Code 'Y'S'p�- Phone360--$2Q-1-2,W Other Ph. 4e90 -2-r:2 Phone - Other Ph. v - 21zi Lien/Title Holder Contractor Reg. Exp. V--.2S—a' Email address Mail Address �'/�e a ._'A 9V fly� MCC.) Drivers Lic.# DOB - - Drivers Lic. ._ DOB 3- 7 "g SEPTIC INFORMATION - Connect to New Septic 24 Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMAT'nN - 12 Digit Parcel No. :5 2 2_3 5: ._ Fire District Legal Description_ Site Address (Please include street name, street number and city)_ Directions to site?/lc�rE-T xA,c :Z(, w4c/lc.d` 0T r Is property within 200'of Saltwater Lake AJ 0 River/Creek A,G—Pond N v Wetland ,Lj l, Seasonal Runoff 46 Stream "0 Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building 17666aj- 4, Z%w%tip Location of Fixtures/Units - 1st Floor Y 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric_ LPC-L___ Natural Gas Heat Pump_ Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps Showers Spot Vent Fan Water Heater Propane Tank �,� Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood `Hosebibs — Dryer Vent 1 Other Other -�i Base Fee / 06c ,fc-j c Ig.--Base Fee 376 d TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop Nork order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X _ Date: ;2— Z�— Z�2cA/O Ow /Owners Repre ntaWe/ tractor/(indicate which one) i� � kA OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group—Type Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood /Gas / Pellet Stove Fee Other Violation Fee TOTAL FEES � ■���■■■�� Ham■■III■ ■■ ■■■■■■■■■■■■■■■S =■■■.f■■■■■ ■ ■�■■����■ ■NONE ■ ■ ■ ■ NOON■■, .��! - . .!�■ ■�■ ■ ■ ■■■■■■ ■�■■■■m■■II►■■MEN ■ NONE ■m uk lum0.momm:■■mo■■■■m ■ MMMINQUINO mommonsNo ■ ■m:"� ■■ ,�■■■■■■■■u ■ ■�■■■ ►•jai■■ �► ■om■ mmoommom rom ■W!1���mmmmm owl SENSE FRIN.- ■����■1VA ■■NNE■■FJR 0 MOMS ■� low ■■moms PH IN ■ ■NEsm-_ SEEN MME ■ EMU ■N U S wvO�AAM� b4i)1 5 � • I J �t 3 3S-(oc7" t�.a.S�.r-�t�k-��.�tr�►,. ���:e� �re�ca-�� 0,C. 4+S two Z.Z 2, -7 - ID o Name, �_T ijCl Parcel# 3 z z 3 2- 7S caoloo BWE ll.1J -. Mason County r� nn Department of Community Development B` r RCE"." Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment', with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site, the creation or addition of impervious surfaces, structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity, and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways, patios, driveways, parking lots or storage areas, concrete or asphalt paving,gravel roads, packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. > >' <:>::>::>::>::>:::;:::::::»:..:.. : .. . ..........................;:..rt.........0 Surface Type Length X Width = Area * All dimensions in feet Buildings X ®( = O s �- X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways 41 X X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X X = Any paved, gravel or packed area per definition X _ above table Others X _.... .. X = Ifi:;t l `tz tal pe rl p ar €#>3 os stte ; X _ velgpi�rttr �ter th�rt 2pQ€f 5clu .fl`a Sri.. ;' :.; tif < <.> 1 Stw €et.utt .1'F�n..� . ....:.:::.:::::.:::::::.:::: .: .:.::::::.:::: #::::::::::::::::::::::::.:::::::::::::::.:.:...............rid.:::. lrn r�rit�t� ::.:.:::::::.:::..::::::.::::::::::... . ..::.: :::..: ....... e. a.. ortt.+ .�l..at~ea .::::::: :.:::.:::::.::::...:..:;>;::;:::..:..:<.;:.;::.::.. .:.::.;.. . :......::::::................. ....... ::::.:.................................................:..::::::.::......:.::::.:::::::: :. . ... .. d If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read, acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owner's legal representative,or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/� gent/Contractor(circle one)Date: Z _ ?_o the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read, acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 . , ! Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC) regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: hitp//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14, Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots;The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A)2�, The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT. 450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th_St�Shelton WA 98584 If this development has, or will have, a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part, that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owner's legal representative, or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/ ent/Contractor(circle one)Date: Page 2 of 2 NORMWEST RESIDENTIAL F RE SPRINKLER, INC. 3503 SOUTH BAY RD NE# WA 98506 360-754-6475 3 DESIGN CALCULATIONS (NFPA 13D) s Sheet No: 1 of I RESIDENTIAL FIRE SPRINKLER SYSTEM Date: ffl•IZ8 I o8 �,� By. Ld)1)(L ntractor's Reg.#NWRESFS085BA Activity# _ZO�g- OO i � �+a••r` � Project Name: r Floor Level: I �1 Project Location: cvTts V1� Union Elev.of Spkrs: Available Water Supply:_2_gp.m. at: p.s.i. Location: Max Sprinkler Spacing:_ ft:x _fL Sprinkler T.D.:V� U n p-, ONE-SPRINKLER DESIGN: Type of Pi in : Min_Flow: g.p.m.; Min.press:�,g p.s.i. VC TWO-SPRINKLER DESIGN: Steel(Sch.40) Min.Flow:2A g.p.m.; Min.press:-1 N p.s.i. Copper K,L,M(Circle one) CALCULATIONS CALCULATIONS 1 Sprinkler flow: System demand= I ,? gpm 2 Sprinkler flow: System demand= gpm PIPING (1 spkr flow) PIPING(1 spkr flow) TOTAL x UNlT = TOTAL TOTAL x UNIT = TOTAL DIA. LENGTH FR LOSS FR LOSS DIA. LENGTH FR LOSS FR LOSS � u Service(Polly) D � .w$R Service(Polly) �,w 3CDJ ,C6 1g System(CPVC) �" 121 •n� g1 System(CPVC) r 2.3'_ _ 2. 1 Plus 15% •49 Plus 15% FITTINGS &VALVES (1 spkr flow) FMINGS&VALVES(2-spkr. Flow= gpm) DIA.& UNIT LENGTH UNIT TOTAL DIA.& UNIT LENGTH UNIT TOTAL TYPE QTY X EQ.LEN. X E.Q.LEN.X FR LASS=F.R DOSS TYPE QTY X EQ.LEN. X E.QIEN.X F.R.DOSS=F.R.[ASS NO v ��I�T' -�s1 a y_ltik .(511(SCL. •r�� Meter Friction Loss(Size=�JJd_�) .O Meter Friction Loss(Size=3/¢`.') S.pp Sprinkler Pressure Required 'I ,g ( Sprinkler Pressure Required Elevation Head Loss( g ft x 0.434) Z Elevation Head Loss( q ft X 0.434) TOTAL System Pressure Demand 2( ,_j TOTAL System Pressure Demand TOTAL Supply Pressure Availablei9d ,6 TOTAL Supply Pressure Available 50,6 O Affordable Fire Protection For Your Family& Home