Loading...
HomeMy WebLinkAboutBLD2015-00695 Solar - BLD Permit / Conditions - 8/17/2015 Inspection Line(360)427-7262 0MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 279 iShelton, WA 98584 MECHANICAL PERMIT BLD2015-00695 OWNER: JEFF GISH RECEIVED: 8/17/2015 CONTRACTOR: SOUTH SOUND SOLAR INC 360.352.7869 LICENSE: SOUTHSS+3N7 EXP: 8/27/2016 ISSUED: 8/17/2015 SITE ADDRESS: 370 E GREAT BEND DR UNION EXPIRES: 2/17/2016 PARCEL NUMBER: 322327590026 LEGAL DESCRIPTION: TR 2-A OF SURV 5/59 TR A-2 OF SP#673; TR 4 OF SP#2687 PCL 8 OF BLA#96-27#625768 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SOLAR PANELS, OVER THE COUNTER CHECKLIST FOR SOLAR BROCKDALE RD, MCREAVY RD, L ON 5TH ST, L ON PORT TOWNSEND, R PANELS WAS COMPLETED ON GREAT BEND DR TO SITE ADDRESS ON THE RIGHT SIDE General Information Setback Information Type of Use: SF Insp.Area: Front: Ft. Shoreline: Ft. Type of Work: ACC Fire Dist.: 6 Rear: Ft. Slope: Ft.Side 1: Ft. Valuation: Side 2: Ft. Mechanical Fixtures FEES Type Qty. Type By Date Amount Receipt Additional Fixtures 1 Mechanical Permit Fee GMM 8/17/2015 $16.90 S120150000C Mechanical Base Fee GMM 8/17/2015 $28.50 S120150000( Building Special inspection GMM 8/17/2015 $73.00 S120150000( Total $118.40 BLD2015-00695 Please refer to the following pages for conditions of this permit. Page 1 of 4 CASE NOTES FOR BLD2015-00695 CONDITIONS FOR BLD2015-00695 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X ,?— 2) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM STANDARDS SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE. X BLD2015-00695 Please refer to the following pages for conditions of this permit. Page 2 of 4 3) The installation of solar(thermal or photovoltaic) energy systems to provide space heating or cooling, hot water and swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code, the International Fire Code, and be shall be listed and labeled in accordance with UL1703. Roof mounted panels shall weigh no more than 3 Ibs/square foot and shall not exceed 1000 lbs. Supports for solar panels are to be installed to spread the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-Ibs are created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the inspection by the Mason County Building Inspector. Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings. Not less than two- 3-foot wide access pathways shall be provided from the eave to ridge. Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection. Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight, collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector. Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit. Solar energy collectors, controls, dampers, fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials, flashed and sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for inspection. X 4) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 2- 5) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org X BLD2015-00695 Please refer to the following pages for conditions of this permit. Page 3 of 4 6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X Z= 7) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X :e_ OWNER /BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. 17 �wr Zol$� nature Date S3� Cl,ay.r.c� OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) BLD2015-00695 Please refer to the following pages for conditions of this permit. Page 4 of 4 0 o CONCRETE Gas Piping MANUFACTURED HOME o Intorlor-Date By n 2 U, Footings/Setbacks Exter+ts _[)aleByRibbons - rn Data BYINSULATION Date By m cLn Foundation Walls BG/SLAB INSULATION Set-up 11 Date By Date By Date By FRAMING Floors FIRE DEPARTMENT Date By pate By Date By Walls PLUMBING Date By Date Ely DECKS Groundwork Vault TANKS Date By Date By Date BY Attic D.W.V Date By OTHER Date BY DRYWALL Type. -- Date By Water Line Date By Type: Date By Int.Brace Wall Date By ZF m MECHANICAL m Separation Date �' FINAL INSPECTION o Date By Date BY Date ' e— /5- By O ° Pass or Request Inspect. rn oType of Insp. Fait I Date Date Done By Comments a�• �,� Ik tS� y�� (.4)%L Cn Y�l by /1e rl 7a 0 a m � I � co cu 0 MASON COUNTY PERMIT NOTA&ZOIE2 DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING a PLANNING,FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext,352 Mason County Bldg. 111,426 West Cedar Street (360)275-4467 Belfair ext. 352 Shelton,WA 98584 (360)482-5269 Elma ext.352 PLUMBING & MECHANICAL PERMIT APPLICATION ............ r ........ OWNER INFORMATION: CONTRACTOR INFO MATT N: NAME: NAME: 5o(.,% e MAILING ADDRESS: 310 ADDRESS:_tjjp bkl MAILING Ltmov\ 1 CITY: VxqwJ STATE:w& ZIP: Jlb!iA74 c rT-Y STATE: WA- ZIP: ff!?!5t7&- PHONE: PHONE:�J CCELL: C -E um EMAIL: r EMAIL : d44K L&I REG# o EXP. /0LJ PARCEL INFORMATION: 1 PARCEL NUMBER(12 DIGIT NUMBER): 3aP,-8a--7 LEGAL DESCRIPTION(.,IBBRI-tlf..171-1) :C SITE ADDRESS: -1 CITY: 0 r)I ovtj DIRECTIONS TO SITE ADDASS: ....................... ................... TYPE OF JOB NEW ADD ALT REPAIR 0TIIE'R—USE,01"BUILDING LOCATION OI-'I,'IX'I'IJRES./t..rNI'I'S— I ST FLOOR 2i"D FLOOR— BASFMFN'I'--..-...GARAGE—OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACII) MECHANICAL UNITS Type of Fixture No. ot*Fixtures Fees Fuel ry,pe:Electric-1.110 Natural Gas Ductless_ Toilets Type of unit No. of Units Fees Bathroom Sink Furnace Bath Tub,, Beat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Siaks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Flood Hose bibs Dryer Vent Ju= Other Solar Pp Othcd'n44UC.41&%" Base Fee Base Fee TOTAL PLUMBIN6 TOTALNIL,CIIANICAL --tL&4—D OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including i any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is I accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. x Signature of Applicant Date X f)CL k0l.,If' Owner/Owners Representative/Contractor Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Jeff and Jana Gish N-lhSm ROOF SPECS: 370 E Great Bend Dr. 0_Solar.- SLOPE: 6/12(26.5°) Union,WA 98592 360.352.7869 TYPE: COMP 425-228-2455 yyww.southsoundsolar.com AZIMUTH: 230' CCB#SOUTHSS902N7 ARRAY FT2=369.62 FT DATE: 8/7/1S DRAWN BY: SW SITE PLAN VERSION 1.0 MAIN E-PANEL NET METER PRODUCTION METER UTILITY DISCONNECT Amok- a � t` of • A • • Built-in-Washington using Cutting Edge High Efficiency Mono Crystalline Cells • 25-Year Power Output Warranty • 10-Year Workmanship Warranty • Exceptional Power Density (watts/m2) • • GENERAL DATA MECHANICAL DATA Cell type 60 Super High Efficiency Mono crystalline cells Dimensions 39.1"X 64.8"X 2" -6 X 10 cell matrix -3 by-pass diodes Weight 43 Ibs Glass Ultra clear,low iron tempered solar glass with anti-glare prismatic subsurface texture Backsheet Multi layered,highly resistant polyester MAXIMUM - ATINGS Frame High strength anodized aluminum frame compatible with both top-down clamps and Operational Temperature -40...+90°C bottom flange mounting -Numerous flange Maximum System Voltage 600V mounting holes on inch dimension centers •Mounting holes specifically for micro- Design Load(UL 1703) up to 1 13 Ibs/ft'- inverter applications Maximum Load(UL 1703) 551 kg/m2(5400 Pa) Cable 42"90C 12 AWG PV wire Maximum Wind Load 113lbs/ft2 Connector MC4 Max Series Fuse Rating 15A Max Reverse Current 15A Grounding Certified for Wiley Electronics WEEB'm grounding clips •Eight standard grounding NOTE: Specifications subject locations per module for reduced ground to change without notice wire length TEMPERATURE RATINGS g++...�............-------.._...- sa%--..._..---...........................,}0..2!`-. 44'L4_0CL 8oY &aY 110C &00' &00' $.x� '4,44' Nominal Operating -� 820°C _ '__._ Temperature effNOCT of P 40.47%/°C Cell icient __._. -----........__.......__ 3 Temperature Co �._� 2 yu^drys '• ; Temperature Coefficient of V 0.32%/"C 1#"?4 rnnrs - � Temperature Coefficient of I +0.04 VIC dro.==.198' Temperature Coefficient of V 0.45%/`C QUALIFICATIONS Li y "---_^---.Wh,p� •?----- UL Listing UL 1703 Fire Rating Class C i \ lac•rr zrw oen,n I :. Made in Washington State • • • ELECTRICAL � . Maximum Power-P.% (Wp) 255 260 265 270 275 280 Maximum Power Voltage-V-0) 31.5 313 31.8 32.0 32.1 32.3 00 dp Maximum Power Current-Ir..(A) 8.1 8.2 8.3 8.4 8.5 8.6 itekenergy • • do Open Circuit Voltage•V,,:(V) 38.4 38.6 38-7 38.9 39.0 39.2 Short Circuit Current-IK(A) 8.8 8.9 9.0 9.1 9.2 9.3 Power Density(W/m) 155.8 158.8 161.9 = 164.9 168.0 171.0 The Best Choice For Solar WA. 360.647.9531 itekenergy.com MN. 612.318.6369 V06.1114 k J , bluefrogsolar YC50OA- MIW Microinverter modules* Single unit connects two solar * Maximum output power 50OW . Individual MPPT for each module modules0 Rated up to 31OW & Up to 14 solar 00 string with a 0A breaker DIMENSIONS 90.1"(2290mm) Our flagship product, the APS YC50OA-MIW is a grid- 8.7„(221mm) - tied microinverter with intelligent networking and monitoring systems to ensure maximum efficiency. Highly dependable and cost effective, the YC500A handles up to 31OW modules with negligible E clipping, delivering 250W AC per module with dual 6.5"(167mm) MPPT. Half the inverters and half the installation _ means real cost savings for residential and . __._.�, commercial customers. f; t f bluefrogsolar.com • r" APS YC500A-M1Wa INPUT DATA (DC) Recommended PV Module Power Range (STC) 180-31OW MPPT Voltage Range 22-45V Maximum Input Voltage 55V Maximum Input Current 12A X 2 OUTPUT DATA (AC) Rated Output Power 50OW Maximum Output Current 2.08A @ 240V 2.4A @208V Nominal Output Voltage/Range-240V 240V/211V-264V' Nominal Output Voltage/Range - 208V 208V/183V-229V' Nominal Output Frequency/Range 60Hz/59.3-60.5Hz' Power Factor >0.99 Total Harmonic Distortion <3% Maximum Units Per Branch 7 per 20A @ 240V 6 per 20A @ 208V EFFICIENCY Peak Efficiency 95.5% CEC Weighted Efficiency 95% Nominal MPP Tracking Efficiency 99.5% MECHANICAL DATA Storage Temperature Range -40OF to +1850F (-40°C to +85°C) Operating Temperature Range (Ambient) -40'F to +149'F (-40°C to +65°C) Operating Temperature Range (internal) -40OF to +1850F (-40°C to +85°C) Dimensions (WxHxD) inches 8.75" x 6.5" x 1.1" Dimensions (WxHxD) mm 221mm x 167mm x 29mm Weight 5.5 Ibs (2.5kg) Enclosure Rating NEMA 4X Cooling Natural Convection FEATURES & COMPLIANCE Communication Power line Design Life 25 years Emissions& Immunity (EMC) Compliance FCC PART 15, ANSI C63.4 2003, ICES-003 Safety Class Compliance UL 1741 ,CSA C22.2, No.107.1-01, NEC2014 690.12 Grid Connection Compliance IEEE 15.47 Specifications subject to change without notice-please ensure you are using the 'Programmable per customer and utility requirements. most recent update found at www.APSamerica.com All settings UL approved 's;6/14 All Rights Reserved Os�OPS bluefrogsolar 1015 Hostmark St., Ste 104, Poulsbo, WA 98370 1 206.855.5149 1 bluefrogsolar.com INSTALLERS - please contact us to join our network of BlueFrogSolar registered installers Jeff and Jana Gish ROOF SPECS: 370 E Great Bend Dr. --Solar.- SLOPE: 6/12(26.5°) Union,WA 98592 360.352.7869 TYPE: COMP 425-228-2455 www.southsoundsolar.com AZIMUTH: 230' CCB#SOUTHSS902N7 ARRAY FT2= 369.62 FT n .` DATE: 8/7/15 i DRAWN BY: SW ` 1-LINE DIAGRAM VERSION 1.0 O ` O ` SYSTEM SPECS: ` 21)ITEK 275 HE MODULES=5.88 KW(S.T.C.) MAX POWER: 275 WATTS Vmp=32.1VDC-Imp=8.5A C O Voc=39 VDC-Isc=9.2 A 1 11) BLUE FROG YC500A-MIW MICRO INVERTERS MAX OUTPUT POWER= 500 WATTS -- - -3---0- za --.0- - -- MAX OUTPUT CURRENT= 2.08A @ 240 VAC O O 0 O MOUNTING SPECS: TOTAL MAX OUTPUT CURRENT=22.88 A -6 SNR RAILS @ 40" -7 SNR RAILS @ 80" -6 SNR RAILS @ 122" 3)#S THHN 3)#10 THHN - 1 SNR RAIL @ 162" W/#10 EG W/#8 EG/GEC =_ ----- - ---- 3/4"EMT 3/4"EMT O 46 SUNMODO FLASHINGS - MASON PUD#1 0 16 SNR GROUND LUGS UTILITY UTILITY AC 240 VAC LOCATED ON LOCATED ON DISCONNECT INVERTER 40 SNR ENDCLAMPS 11 INSIDE WEST WEST WALL 2P 3R 60A COMBINER PANEL 22 SNR MIDCLAMPS WALL OF GARAGE OF GARAGE 2P 125A 3R M.L.O. 22 MICRO ATTACHMENTS MAIN PANELF 2P20A ���C 200A BUS RATING Im 2P40A 2S 2P20A PRODUCTION METER BI 2S NET METER 200A LOAD LOAD I I LOCATED ON #6 BARE GEC WEST WALL CONNECTS TO EXISTING OF GARAGE GROUNDING ELECTRODE 1 . --------------------------------------j