HomeMy WebLinkAboutBLD2015-00695 Solar - BLD Permit / Conditions - 8/17/2015 Inspection Line(360)427-7262
0MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. 3 426 W. Cedar P.O. Box 279
iShelton, WA 98584
MECHANICAL PERMIT BLD2015-00695
OWNER: JEFF GISH RECEIVED: 8/17/2015
CONTRACTOR: SOUTH SOUND SOLAR INC 360.352.7869 LICENSE: SOUTHSS+3N7 EXP: 8/27/2016 ISSUED: 8/17/2015
SITE ADDRESS: 370 E GREAT BEND DR UNION EXPIRES: 2/17/2016
PARCEL NUMBER: 322327590026
LEGAL DESCRIPTION: TR 2-A OF SURV 5/59 TR A-2 OF SP#673; TR 4 OF SP#2687 PCL 8 OF BLA#96-27#625768
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
NEW SOLAR PANELS, OVER THE COUNTER CHECKLIST FOR SOLAR BROCKDALE RD, MCREAVY RD, L ON 5TH ST, L ON PORT TOWNSEND, R
PANELS WAS COMPLETED ON GREAT BEND DR TO SITE ADDRESS ON THE RIGHT SIDE
General Information Setback Information
Type of Use: SF Insp.Area: Front: Ft. Shoreline: Ft.
Type of Work: ACC Fire Dist.: 6 Rear: Ft. Slope: Ft.Side 1: Ft.
Valuation:
Side 2: Ft.
Mechanical Fixtures FEES
Type Qty. Type By Date Amount Receipt
Additional Fixtures 1 Mechanical Permit Fee GMM 8/17/2015 $16.90 S120150000C
Mechanical Base Fee GMM 8/17/2015 $28.50 S120150000(
Building Special inspection GMM 8/17/2015 $73.00 S120150000(
Total $118.40
BLD2015-00695 Please refer to the following pages for conditions of this permit. Page 1 of 4
CASE NOTES FOR
BLD2015-00695
CONDITIONS FOR
BLD2015-00695
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X ,?—
2) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON
STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM
STANDARDS SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE.
X
BLD2015-00695 Please refer to the following pages for conditions of this permit. Page 2 of 4
3) The installation of solar(thermal or photovoltaic) energy systems to provide space heating or cooling, hot water and swimming pool heating shall
conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code, the International
Fire Code, and be shall be listed and labeled in accordance with UL1703.
Roof mounted panels shall weigh no more than 3 Ibs/square foot and shall not exceed 1000 lbs. Supports for solar panels are to be installed to spread
the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-Ibs are created. Panels may be installed
on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered
analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with
manufacturer specifications provided during the inspection by the Mason County Building Inspector.
Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points
shall not be located in areas where access ladders would block window or doors openings. Not less than two- 3-foot wide access pathways shall be
provided from the eave to ridge.
Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection.
Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction
Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight, collector
maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector.
Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems
containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be
equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the
dwelling to 180 degrees Fahrenheit.
Solar energy collectors, controls, dampers, fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof
shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials, flashed and
sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to
verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an
engineered design for inspection.
X
4) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X 2-
5) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been
identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or
operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
X
BLD2015-00695 Please refer to the following pages for conditions of this permit. Page 3 of 4
6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinances and building regulations.
X Z=
7) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prevented action from being taken. No more than one extension may be granted.
X :e_
OWNER /BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
17 �wr Zol$�
nature Date
S3� Cl,ay.r.c� OWNER - REPRESENTATIVE - CONTRACTOR
Print Name (Circle one to indicate)
BLD2015-00695 Please refer to the following pages for conditions of this permit. Page 4 of 4
0
o CONCRETE Gas Piping MANUFACTURED HOME
o Intorlor-Date By n 2
U, Footings/Setbacks Exter+ts _[)aleByRibbons -
rn Data BYINSULATION Date By m
cLn Foundation Walls BG/SLAB INSULATION Set-up 11
Date By Date By Date By
FRAMING Floors FIRE DEPARTMENT
Date By pate By
Date By Walls
PLUMBING Date By Date Ely
DECKS
Groundwork Vault
TANKS
Date By Date By
Date BY Attic
D.W.V Date By OTHER
Date BY DRYWALL Type.
-- Date By
Water Line Date By
Type:
Date By Int.Brace Wall Date By
ZF
m MECHANICAL m Separation Date �' FINAL INSPECTION o
Date By Date BY Date ' e— /5- By
O
° Pass or Request Inspect. rn
oType of Insp. Fait I Date Date Done By Comments
a�• �,� Ik tS� y�� (.4)%L
Cn
Y�l by /1e rl 7a
0
a
m
� I �
co
cu
0
MASON COUNTY PERMIT NOTA&ZOIE2
DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING a PLANNING,FIRE MARSHAL
WWW.CO.MASON.WA.US (360)427-9670 Shelton ext,352
Mason County Bldg. 111,426 West Cedar Street (360)275-4467 Belfair ext. 352
Shelton,WA 98584 (360)482-5269 Elma ext.352
PLUMBING & MECHANICAL PERMIT APPLICATION
............
r ........
OWNER INFORMATION: CONTRACTOR INFO MATT N:
NAME: NAME: 5o(.,% e
MAILING ADDRESS: 310 ADDRESS:_tjjp bkl MAILING Ltmov\
1 CITY: VxqwJ STATE:w& ZIP: Jlb!iA74 c rT-Y STATE: WA- ZIP: ff!?!5t7&-
PHONE:
PHONE:�J CCELL: C -E um
EMAIL: r EMAIL : d44K
L&I REG# o EXP. /0LJ
PARCEL INFORMATION:
1 PARCEL NUMBER(12 DIGIT NUMBER): 3aP,-8a--7
LEGAL DESCRIPTION(.,IBBRI-tlf..171-1) :C SITE ADDRESS: -1 CITY: 0 r)I ovtj
DIRECTIONS TO SITE ADDASS:
....................... ...................
TYPE OF JOB
NEW ADD ALT REPAIR 0TIIE'R—USE,01"BUILDING
LOCATION OI-'I,'IX'I'IJRES./t..rNI'I'S— I ST FLOOR 2i"D FLOOR— BASFMFN'I'--..-...GARAGE—OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACII) MECHANICAL UNITS
Type of Fixture No. ot*Fixtures Fees Fuel ry,pe:Electric-1.110 Natural Gas Ductless_
Toilets Type of unit No. of Units Fees
Bathroom Sink Furnace
Bath Tub,, Beat Pump
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kitchen Siaks Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust Flood
Hose bibs Dryer Vent Ju=
Other Solar Pp
Othcd'n44UC.41&%"
Base Fee Base Fee
TOTAL PLUMBIN6 TOTALNIL,CIIANICAL --tL&4—D
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare
that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including
i any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is
I accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This
permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is
suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
x
Signature of Applicant Date
X f)CL k0l.,If' Owner/Owners Representative/Contractor
Print Name (indicate which one)
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
Jeff and Jana Gish N-lhSm ROOF SPECS:
370 E Great Bend Dr. 0_Solar.- SLOPE: 6/12(26.5°)
Union,WA 98592 360.352.7869 TYPE: COMP
425-228-2455 yyww.southsoundsolar.com AZIMUTH: 230'
CCB#SOUTHSS902N7 ARRAY FT2=369.62 FT
DATE: 8/7/1S DRAWN BY: SW
SITE PLAN VERSION 1.0
MAIN E-PANEL
NET METER
PRODUCTION METER
UTILITY DISCONNECT
Amok-
a �
t`
of
• A •
• Built-in-Washington using Cutting Edge
High Efficiency Mono Crystalline Cells
• 25-Year Power Output Warranty
• 10-Year Workmanship Warranty
• Exceptional Power Density (watts/m2)
• • GENERAL DATA MECHANICAL DATA
Cell type 60 Super High Efficiency Mono crystalline cells Dimensions 39.1"X 64.8"X 2"
-6 X 10 cell matrix -3 by-pass diodes
Weight 43 Ibs
Glass Ultra clear,low iron tempered solar glass with
anti-glare prismatic subsurface texture
Backsheet Multi layered,highly resistant polyester MAXIMUM -
ATINGS
Frame High strength anodized aluminum frame
compatible with both top-down clamps and Operational Temperature -40...+90°C
bottom flange mounting -Numerous flange Maximum System Voltage 600V
mounting holes on inch dimension centers
•Mounting holes specifically for micro- Design Load(UL 1703) up to 1 13 Ibs/ft'-
inverter applications Maximum Load(UL 1703) 551 kg/m2(5400 Pa)
Cable 42"90C 12 AWG PV wire Maximum Wind Load 113lbs/ft2
Connector MC4 Max Series Fuse Rating 15A
Max Reverse Current 15A
Grounding Certified for Wiley Electronics WEEB'm
grounding clips •Eight standard grounding NOTE: Specifications subject
locations per module for reduced ground to change without notice
wire length
TEMPERATURE RATINGS
g++...�............-------.._...- sa%--..._..---...........................,}0..2!`-.
44'L4_0CL 8oY &aY 110C &00' &00' $.x� '4,44' Nominal Operating
-� 820°C
_ '__._ Temperature effNOCT of P 40.47%/°C
Cell
icient
__._. -----........__.......__ 3 Temperature Co
�._� 2 yu^drys '• ; Temperature Coefficient of V 0.32%/"C
1#"?4 rnnrs - � Temperature Coefficient of I +0.04 VIC
dro.==.198'
Temperature Coefficient of V 0.45%/`C
QUALIFICATIONS
Li
y "---_^---.Wh,p� •?----- UL Listing UL 1703
Fire Rating Class C
i \ lac•rr zrw oen,n I :.
Made in Washington State
• • • ELECTRICAL � .
Maximum Power-P.% (Wp) 255 260 265 270 275 280
Maximum Power Voltage-V-0) 31.5 313 31.8 32.0 32.1 32.3 00 dp
Maximum Power Current-Ir..(A) 8.1 8.2 8.3 8.4 8.5 8.6 itekenergy
• • do
Open Circuit Voltage•V,,:(V) 38.4 38.6 38-7 38.9 39.0 39.2
Short Circuit Current-IK(A) 8.8 8.9 9.0 9.1 9.2 9.3
Power Density(W/m) 155.8 158.8 161.9
= 164.9 168.0 171.0 The Best Choice For Solar
WA. 360.647.9531
itekenergy.com MN. 612.318.6369
V06.1114
k
J ,
bluefrogsolar
YC50OA- MIW
Microinverter
modules* Single unit connects two solar
* Maximum output power 50OW
. Individual MPPT for each module
modules0 Rated up to 31OW
& Up to 14 solar 00
string with a 0A breaker
DIMENSIONS
90.1"(2290mm) Our flagship product, the APS YC50OA-MIW is a grid-
8.7„(221mm) - tied microinverter with intelligent networking and
monitoring systems to ensure maximum efficiency.
Highly dependable and cost effective, the YC500A
handles up to 31OW modules with negligible
E
clipping, delivering 250W AC per module with dual
6.5"(167mm) MPPT. Half the inverters and half the installation
_ means real cost savings for residential and
. __._.�,
commercial customers.
f; t
f
bluefrogsolar.com
•
r"
APS YC500A-M1Wa
INPUT DATA (DC)
Recommended PV Module Power Range (STC) 180-31OW
MPPT Voltage Range 22-45V
Maximum Input Voltage 55V
Maximum Input Current 12A X 2
OUTPUT DATA (AC)
Rated Output Power 50OW
Maximum Output Current 2.08A @ 240V 2.4A @208V
Nominal Output Voltage/Range-240V 240V/211V-264V'
Nominal Output Voltage/Range - 208V 208V/183V-229V'
Nominal Output Frequency/Range 60Hz/59.3-60.5Hz'
Power Factor >0.99
Total Harmonic Distortion <3%
Maximum Units Per Branch 7 per 20A @ 240V 6 per 20A @ 208V
EFFICIENCY
Peak Efficiency 95.5%
CEC Weighted Efficiency 95%
Nominal MPP Tracking Efficiency 99.5%
MECHANICAL DATA
Storage Temperature Range -40OF to +1850F (-40°C to +85°C)
Operating Temperature Range (Ambient) -40'F to +149'F (-40°C to +65°C)
Operating Temperature Range (internal) -40OF to +1850F (-40°C to +85°C)
Dimensions (WxHxD) inches 8.75" x 6.5" x 1.1"
Dimensions (WxHxD) mm 221mm x 167mm x 29mm
Weight 5.5 Ibs (2.5kg)
Enclosure Rating NEMA 4X
Cooling Natural Convection
FEATURES & COMPLIANCE
Communication Power line
Design Life 25 years
Emissions& Immunity (EMC) Compliance FCC PART 15, ANSI C63.4 2003, ICES-003
Safety Class Compliance UL 1741 ,CSA C22.2, No.107.1-01, NEC2014 690.12
Grid Connection Compliance IEEE 15.47
Specifications subject to change without notice-please ensure you are using the 'Programmable per customer and utility requirements.
most recent update found at www.APSamerica.com All settings UL approved
's;6/14 All Rights Reserved Os�OPS bluefrogsolar
1015 Hostmark St., Ste 104, Poulsbo, WA 98370 1 206.855.5149 1 bluefrogsolar.com
INSTALLERS - please contact us to join our network of BlueFrogSolar registered installers
Jeff and Jana Gish ROOF SPECS:
370 E Great Bend Dr. --Solar.- SLOPE: 6/12(26.5°)
Union,WA 98592 360.352.7869 TYPE: COMP
425-228-2455 www.southsoundsolar.com AZIMUTH: 230'
CCB#SOUTHSS902N7 ARRAY FT2= 369.62 FT n .`
DATE: 8/7/15 i DRAWN BY: SW `
1-LINE DIAGRAM VERSION 1.0
O `
O `
SYSTEM SPECS: `
21)ITEK 275 HE MODULES=5.88 KW(S.T.C.)
MAX POWER: 275 WATTS
Vmp=32.1VDC-Imp=8.5A C O
Voc=39 VDC-Isc=9.2 A 1
11) BLUE FROG YC500A-MIW MICRO INVERTERS
MAX OUTPUT POWER= 500 WATTS -- - -3---0- za --.0- - --
MAX OUTPUT CURRENT= 2.08A @ 240 VAC O O 0 O MOUNTING SPECS:
TOTAL MAX OUTPUT CURRENT=22.88 A
-6 SNR RAILS @ 40"
-7 SNR RAILS @ 80"
-6 SNR RAILS @ 122"
3)#S THHN 3)#10 THHN - 1 SNR RAIL @ 162"
W/#10 EG W/#8 EG/GEC =_ ----- - ----
3/4"EMT 3/4"EMT
O 46 SUNMODO FLASHINGS -
MASON
PUD#1 0 16 SNR GROUND LUGS
UTILITY UTILITY AC
240 VAC LOCATED ON LOCATED ON DISCONNECT INVERTER 40 SNR ENDCLAMPS
11 INSIDE WEST WEST WALL 2P 3R 60A COMBINER PANEL 22 SNR MIDCLAMPS
WALL OF GARAGE OF GARAGE 2P 125A 3R M.L.O.
22 MICRO ATTACHMENTS
MAIN PANELF 2P20A
���C
200A BUS RATING
Im 2P40A
2S 2P20A
PRODUCTION
METER
BI 2S
NET METER
200A LOAD
LOAD I
I
LOCATED ON #6 BARE GEC
WEST WALL CONNECTS TO EXISTING
OF GARAGE GROUNDING ELECTRODE
1
. --------------------------------------j