Loading...
HomeMy WebLinkAboutBLD2008-00367 Garage - BLD Permit / Conditions - 5/8/2008 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2008-00367 OWNER: ALLEN BAHR RECEIVED: 4/1/2008 CONTRACTOR: LICENSE: EXP: ISSUED: 5/8/2008 SITE ADDRESS: 41 E GARNET CT UNION EXPIRES: 11/8/2008 PARCEL NUMBER: 322327590012 LEGAL DESCRIPTION: PCL 10 OF BLA#97-23 S 5/59 PROJECT DESCRIPTION: DIRECTIONS TO SITE: Garage. MCREAVY RD TOWARD UNION, L ON UNION HEIGHTS DR, R ON UNION HEIGHTS PL NORTH, FOLLOW TO GARNET CT ON THE RIGHT TO SITE ADDRESS. General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: V-B Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U-1 Lot Size: Deck: Type of Work: ACC Fire Dist.: 6 No. of Stories: 1 Occ. Load: Building: Garage-Detached 660 Valuation: Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: S 38.0 Ft. Shoreline: Ft. Water Body: Rear: N 198.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Shoreline Desig.: Side 1: E 4.0 Ft. Year: Serial No.: Side 2: W Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee KKK 4/1/2008 $199.71 S22008000 Planning Review Fee KKK 4/1/2008 $190.00 S22008000 EH Plan Review TW 4/7/2008 $40.00 S12008000 Building State Fee RTB 4/10/2008 $4.50 S12008000 Building Permit Fee RTB 4/10/2008 $307.25 S12008000 Geotechnical Asses. Report SDP 5/6/2008 $320.00 S12008000 Total $1,061.46 BLD2008-00367 Please referto the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2008-00367 CONDITIONS FOR BLD2008-00367 1) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X � 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X CO 3) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. x l 4) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X C 5) All other necessary permits from Mason County, Washington State and/or Federal Agencies that a&r required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X 6-�Q-5 6) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X CT5 7) Ownerl Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 8) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X CtD 9) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit sk-ll be applied for, reviewed and approved prior to the change. x c_. BLD2008-00367 Please referto the following pages for conditions of this permit. 2 of 5 10) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X ("5- 11) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Build' Department prior to any further inspections being performed or approvals granted. X 12) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contragor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X Cfi 13) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 6 14) This structure is limited to U-occupancy use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved. X 15) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X C 16) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your projegt. X 0 17) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 6q BLD2008-00367 Please referto the following pages for conditions of this permit. 3 of 5 18) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspeor shall be made prior to requesting additional inspections. X (' 19) All property lines shall be clearly identified at the time of foundation inspection. X 66 20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X& 21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 29 (�22) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and /or land modifications (grading, cuts, fills, etc.) required in the geotechnical report/assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X41.6 1 �/123) An inspection performed by a representative of the geologist, their authorized representative, or engineer of record, shall be completed on-site prior to the footing pour to verify that earthwork and foundation installation activities comply with the Geotechnical report or assessment recommendations. In addition a final inspection report, prepared by a representative of the geologist, their authorized representative, or engineer of record shall be required to verify that erosion control, drainage and final work is completed in accordance to the Geotechnical report or assessment recommendations. Reports shall be submitted to the Mason County Building Dept., PO Box 186, Shelton, WA 98584, prior to the footing and final inspections and available for ction. X X 24) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X a 25) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. XZ _ Please refer to the following pages for conditions of this permit. 4 of 5 BLD2008 00367 9 26) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed. X 27) Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project. X Gjj 28) Prior to final approval, all upland areas disturbed or new y created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 29) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established. X Gd3 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for revie and inspection. OWN ER OR AGENT: r DATE: BLD2008-00367 Please referto the following pages for conditions of this permit. 5 of 5 MASON COUNTY PERMIT NO. BUILDING PERMIT APPLICATION 44mw>►�.. 426 W. Cedar• R 0. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 Q,A On the web www.co.mason.wa.us APPLICA111T INFORM ION CONTRACTOR INFORMATION Owner 1, 90" Rh* 0. B'4H4 Company Name Mailinq Address P, Mailing Address City Sta Zip Code City State Zip Code j Phon er Ph. Phone Other Ph. Lien/Title Holder 92 Qe4 Contractor Reg. # Exp. E mail address ` E Mail Address Drivers Lic.# DOB —� Drivers Lic. # DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic ✓ Existing Septic ✓ Connect to Water System ✓ Name of Water System ;>. U—n J/ flora Tt/ Well .' 4A Sewer SystemW Name of Sewer Syste PARCEL INFORMATION - 12 Digit P rcel IN Fire District 6 j Legal Description 1d CL /D o 8L4 k- -- _'" Site Address (Please include street name, street number and city) ` Directions to site - OWEV-L •° Will timber be cut and sold in parcel pr paration?Yes Is property wthin 200' of Saltwater Lake River/Creek Pony _ Wetland ! Seasonal Runoff Stream Slopes or Bluffs 150%�Kt Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New_Y_Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building 47ZV24`2' 7 Describe Work��0 'Al TC Ae [`y. No. of Bedrooms No. of Bathrooms Square Footage- 1 st Floor 2nd Floor 3rd Floor Basement .,Re Covered Deck Other Sq. ft. Attached _. - Detached Carport Attached Detached Garage ` MANUFACTURED HOME INFORMATION - Make Model Year Length— Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the informaticn provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OFAPROGRESS INSPECTI N.INACTIVITY OF-THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THEAPPLICATION. Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Planning Department Environmental Health Department Fire Marshal FEES Building Permit Fee D .Z Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood/Gas/ Pellet Stove Fee — State Fee L on Fee - - Pre-Paid at Submittal ion $ TOTAL FEES zY P. o. Box 5 77 1200 1- PLANNING : „ ALL SETBACKS ARE MEASURED SC016/ c O FROM THE FU TH EST > .o rI�t9RDING 1, �l6RTt/di� �R.O(�CCda�2 f�ly� i Le�e28eaoK�.Q�e _ f� 9 T "7-"t At Raa�T�v�i d/l • �- . e ,le-r8e-K an 21ce9 003-7 � q coo e L,o liGr_ M StTc 4ZO pZ APPROVED ot�D•b ��,, , _,, �` MASON COUNTY DCD PLANNING SITE PLAN REIQUIRED TO BE ON SITE CHANGES SVBJECTTOAPPR V I Q By - Date - s-riweT q.hE CQAffcl- CT PROPeaT Li uc /aQ ' Pwo- Y Name&Z � Parcel - q`,-'JW 1-9, BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment`, with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site, the creation or addition of impervious surfaces, structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity, and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to, rooftops,walkways, patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads, packed earthen materials,and oiled, macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. :: i?l1# . FIIfF3 15.T �3��: : � G��CUI�18 IfXI *llrlE3LT5 ft1 e>I ` '.: 1. 1�. Surface Type Length X Width = Area * All dimensions in feet Buildings X j X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways X X ) = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = PatiosMalks 1 X = X = Any paved, gravel or packed area per definition above table X = ......................................................................................................................... ......................................................................................................................... ......................................................................................................................... Others X = ....."'```'` r3s>at` . >2i3131 is ua % a ti; teti ..,:. 3ts rti .th........................ ............................. ... ...................................................................................................... utrt�............ ................... ... Total..m . . . . ctrface.Afe. .sutrt.of ati.areas"> < . ..:. :........:... If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read, acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described prope for review and' pection as may be required. X Owner/Agent/Contractor(circle one)Date: G If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read, acknowledge and sign the information provided on page 2 of 2. Page I of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code (MCC) regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/conuniss-loners/index.htm Please follow the links to "Title 14, Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout' PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT. 450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has, or will have, a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative, or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2