HomeMy WebLinkAboutBLD2000-01503 SFR - BLD Permit / Conditions - 2/23/2001 Inspection Line (360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. 3 426 W. Cedar P.O. Box 186 1
Shelton, WA 98584 0`-'1
lip; RESIDENTIAL BUILDING PERMIT BLD2000-01503
OWNER: TERRY KNOBLOCH 253-841-2581 RECEIVED: 12/01/2000
CONTRACTOR: DOGWOOD CONSTRUCTI
SITE ADDRESS: 21 E GARNET CT UNION ISSUED: 0
PARCEL NUMBER: 322327590011 EXPIRES: 08/23/2001
/23/2001
LEGAL DESCRIPTION: TR 1-A OF SURVEY 5/59, TR 1 OF SP#2688
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
RESIDENCE NORTH ON BROCKDALE TO MCREAVY, LEFT ON UNION HEIGHTS DRIVE
RIGHT ON UNION HEIGHTS PL NORTH TO GARNET, CORNER LOT
General Information Construction & Occupancy Information Square Footage Information
No. of Bedrooms: 2 Type of Constr.: V-N
Type of Use: SF Insp. Area: No. of Bathrooms: 1 Occ. Group: R-3 Lot Size: Deck: 564
Type of Work: ACC Fire Dist.: 6 No. of Stories: 1 Occ. Load: Building:1,500 0
Valuation: $83,628 Buil ing Height: 16 Occ. Status: Basement:
Manufactured Home Information Setback Information Shoreline & Planning Information
Make Length: Ft. Front: S 149.0 Ft. Shoreline: Ft. Water Body:
Rear: N 52.0 Ft. Slope: 0.1 Ft. SEPA?: No
Model: Width: Ft. Side 1: E 100.0 Ft. Shoreline Desig.:
Year: Serial No.: Side 2: W 49.0 Ft. Comp. Plan Desi .: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Dishwasher 1 Exhaust Hood 1 Plan Check Fee KLW 12/01/200 $550.39 55144
Hosebibs 2 Furnace<100K 1 Address Fee GMM 12/04/200 $15.00 55681
Kitchen Sink 1 Gas Outlets 2 Planning Review Fee SLO 01/12/200 $38.00 55681
Lavatories 2 Propane Tank 1 Public Works Review SLO 01/12/200 $32.19 55681
Showers 1 Ventilation Fan 3 Building State Fee MEC 02/05/200 $4.50 55681
Water Closets (Toilets) 2 WOodStove 1 Building Permit Fee MEC 02/05/200 $881.75 55681
Water Heaters 1 Dryer Vent 1 Mechanical Fee MEC 02/05/200 $117.75 55681
Bath Tubs 1 Mechanical Base Fee MEC 02/05/200 $23.50 55681
Clothes Washer 1 Plumbing Fee MEC 02/05/200 $75.00 55681
Plumbing Base Fee MEC 02/05/200 $20.00 55681
EH Plan Review PSD 02/14/200 $50.00 55681
Total $1,808.08
BLD2000-01503 Please refer to the following pages for conditions of this permit. 1 of 5
I
CASE NOTES FOR
BLD2000-01503
CONDITIONS FOR
BLD2000-01503
1) This application i ject to Buffer and Landscaping requirements as established under Mason County Ordinance
1.03.036.X
2) The use, handling and storage of hazardo s materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval
of the Mason County Fire Marshal. X �
3) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely
impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of
the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For
further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or
access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future
planned work whi affect your project.
X
4) Proposed structure or any portion thereof greater than 30" in height from gr a ine, must maintain a minimum of 5'setback from all property lines,
easements and 10'from all County and State Road right of ways. X
5) All upland areas disturbed or ne reated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt
fencing or straw matting). X
6) All con ' ' ns and recommendations in the geo-assessment prepared by Bradley-Noble dated December 3, 2000 shall be followed.
X�
7) The Mason County Resource Lands and Critical Areas Ordinance requires vegetative management of the site. There shall be a minimum disturbance
of trees and vegetation in order to minimize erosion and stabilize Landslide Hazard Areas. Limbing trees for vie ur oses is preferred over tree
removal. Vegetation removal on the slopes of banks shall be minimized due to the potential for erosion.X_ �
BLD2000-01503 Please refer to the following pages for conditions of this permit. 2 of 5
8A Regulations which apply for GRADING of the site (per Mason County Resource Lands and Critical Areas Resource Ordinance):
A..No grading shall be performed in Landslide Hazard Areas or slide prone areas prior to obtaining a grading permit subject to approval by the Director
and based on recommendations contained in the geotechnical report with slope stability analysis and grading recommendations.
B. Clearing, grading, and other construction activities shall not aggravate or result in slope instability or surface sloughing.
C. Undergrowth shall be retained to the extent feasible.
D. Clearing methods which minimize soil disturbance shall be used.
E. No fill, dead vegetation (slash/stumps), or other foreign material shall be placed within a Landslide Hazard Area.
X�/`
9) Site is located within an unstable Landslide Hazard Area. Development should be designed to preserve the natural drainage courses in the area.
Surface drainage, including downspouts, shall not be directed onto or within 50 feet above or onto the face of a Landslide Hazard Area or it's associated
buffer. If drainage must be discharged from the top of a Landslide Hazard Area to below it's toe, it shall be collected above the top and directed to
below the toe by tight-line drain and provided with an energy dissipating device at the toe.
X
10) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and must be collected by the
Build* Department prior to any further inspections being performed or approvals granted.
X y-57
11) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and
legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site
inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or
contr�qor fail to post the address on site prior to requesting inspections.
12) The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must
remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they
shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of
plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building
inspects.
X y�/1
13) The"approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then
approval will not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and shall be collected
by the wilding Department prior to any further inspections being performed or approvals granted.
Y
BLD2000-01503 Please refer to the following pages for conditions of this permit. 3 of 5
14) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion
air from e in accordance with the Uniform Mechanical Code.
X
15) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee of$47.00 per hour(minimum 1 hour) will be charged
and shalom collected by the Building Department prior to any further inspections being performed or approvals granted.
16) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason
County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or
occu=_ 1d result in permit revocation.
X
17) Installation of heating equipment in single family residences shall meet the requirement of the 1991 WSEC. The furnace to be installed shall not
exceed 150% of the heating design load or prescriptive requirements of Chapter 9. Furnace efficiency shall be .78 AFUE or higher. Ducts shall be
taped, aled and mechanically fastened with a minimum of 3 fasteners per joint. Ducts shall be insulated to R-8.
X
18) Proposed structure or any portion thereof greater than 30" in height from grade line, must maintain a minimum of 5'setback from all property lines,
easements and 10' from all County and State Road right of ways. X�
19) All changes to "approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County
ordin a or regulation, must be reviewed and approved by Mason County prior to construction.
X
20) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall be made prior to requesting additional inspections.
' I
21) All property lines shall be clearly identified at the time of foundation inspection. X
22) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-co Mason County ordinances and building regulations.
X ���
23) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time
for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the
permit holder have prevented action from being taken. No more than one extension may be granted.
X �,
BLD2000-01503 Please refer to the following pages for conditions of this permit. 4 of 5
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period
of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection
must be approved before bui ing can be occupied. n
OWNER OR AGENT: DATE: ?
BLD2000-01503 Please refer to the following pages for conditions of this permit. 5 of 5
i
CONCRIFtE MECHANICAL MOBILE HOME
Footings-Setback date �,, -' &-"C( by Ribbons
date Gas Piping date b
Foundation Walls date by Set Up
date by INSULATION date by
3G/S!AB Insulation Floors Final
date by date by date by
FfYkMING Walls FIRE DEPT.
data /'(' by date by
O_�t `��( by
PLUMBING date OTHER
Groundwork Attic
date by datef'd'/� Z00/ by
D.W.V. WALLBOARD NAILING
date 6-V .?p(4 by date o -rG ZC;ty
Water Line FINAL INSPECTION
date - - r by — i date ty,Z by date by
pl � �.�! � Sc'C �7.9iC' F ,�.eEL'�U.e� /L�i O•E/.�iT�
14 mat! Pi��SEp _
1 �
��-
�`' oot X 41110vvv LL'�*S &,Ue 4N /�r15✓yam �'�
ZDoZ
I
January 6,2001
Mike:
I have reviewed the Terry Knobloch Residence project,Permit#BLD2000-01503 and I find the following
items that need correction.
1. The lot dimensions are not given on the site plan.
2. No elevations are given on the topographical cross section or the site plan.
3. There was no energy information with the submittal and no heat source was specified. Therefore the
energy calculations could not be checked.
4. The engineering could not be verified because there is nothing on the engineering calculations to
indicate what snow load had been used. There was a reference on the plans to 251b snow loads but not on
the stamped engineering. It should be noted that none of the structural loads have been checked. I did,
however show the tributary loads on the roof beams and major headers assuming a 25 lb snow load.
5. A soil bearing of 2,000 P.S.F.was assumed on the plans. UBC Table 18-1-A requires that 1,500 P.S.F.
be used for sandy soils unless data is provided to indicate otherwise. No such data was provided.
6. The kitchen area is completely blank. I assumed the usual equipment and used that for permit
valuations.
7. No grade and species were given other than"Group III "framing material.
I have completed the as ch of the review as possible. The plan is NOT approved.
Th u,
She an
CodePro onsulting
PERMIT NO.: BLD
MASON COUNTY I
BUILDING PERMIT APPLICATION t I �
426 W.Cedar/P.O.Box 186,Shelton,WA 98584
Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968
APPLICANT INFORMATION CONTRACTOR INFORMATI0
1
Owner`-escIpT &yr gAw gtJo S .#C H Contractor Name nQ9 ID c
Mailing Address /' a A -nd AuE. G . Mailing Address E I& W 15 t
City&u V.4LLV4 State LM&Zip Code q 13 7S" City 0"1 D V'1 State Zip Code
Phone(Z SLI) 4141.258/ Othe U rPh. Ph.( 3(0 ) 8 */ i
ther Ph.( 8
Lien/Title Holder1. v LoG Contractor Reg # OC,*0 0Address /7 9 Id Expiration o?Dp
SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic Existing Septic_)L_Connect to Sewer
System Name of Sewer System Well Water System Name of
Water System p to in f
PARCEL INFORMATION-12 digit Tax Parcel No. 37 2 3 2. /1.�/ c7ad Z Fire District �y
Legal Description
Site Address(Please include street name, street n ber and city)
Directions to site -
N'f //fX�kfs A. NI�f�1 ,� �IF9AO.vFTr fod���LvT
Will timber be cut and sold in parcel preparati6ril (Yes/No)_ALdL_
Is your property within 200' of the following: Body of Water(Name) Saltwater
Lake River/Creek Pond Wetland Seasonal Runoff Stream YSlopes or
Bluffs
PERMANENT RESIDENCE❑ SEASONAL RESIDENCE❑
TYPE OF JOB New_)(,_Add Alt Repair Other Use of Building
Describe Work e-4.0,45t
No. of Bedrooms-4Nc; of Bathrooms :1 SQUARE FOOTAGE-1 st Floor/5p d 2nd Floor
3rd Floor Loft Basement Deck Other sq. ft.
Garaig
,!__)(__Attached_jrDetached Carport Attached Detached
MOBILE HOME INFORMATION-Make Model Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Prioe $ Replacement Unit ?(Yes/No)
Installer Name Certification No.
NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF
CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the
information provided is accurate and grants employees of Mason County access to the above described property and structures for review and
inspection of this project. Acknowledgment of such is by signature below:
OWNER AFFIDAVIT-I c<ify that I am exenVt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a
Contractor Registration`4aw RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance
requirements for which this permit is issued and that all work will be done in requirements regulating the wotR for which this permit is issued and all work
conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without
approval. first obtaining approval,
Date X / , U� Date 110
FOR OFFICIAL USE BEYOND THIS POIN_T.l
Accepted by Date Su Ittal Amount Due Receipt N�
DEPARTMENT,AI»,RE1/I W APPROVED, DENIED' CONDITION CODES
Building Departmm ,�
Occ GroupIE^ T e C nst
Planning Department
Environmental Health Department
Public Works Department
Fire Marshal
Valuation $
FEES
Building Permit Fee Site Inspection
Plan Review Fee EH Review Fee
Plumbing&Base Fee Planning Review Fee
Mechanical&Base Fee Other
Wood/Gas/Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal ( )
TOTAL FEES
Fie: ALL icer� 1✓��,-� oA�:
1 Subiect to Change Without Notice
FEBRUARY 5. 1993
- EXTERIOR DOORS
owl
gal an
sol 804 Sod 807 all Ala A14
r �
4; %1 -
i ii it i
ii 711 4 ,>ZIIfO am I Tim ! WU I Xm 1iJ0 �
ety ass re a�pligue
Gulls included on Bab, B18, A14
Jambs for 2x6 wall
Deadbolt lock & passage set
Door swings in
b - door swims out
2x4 jamb UP(T 2x6)
- key to knob (IPO deadbolt & passage)
- for use as a garage service door only
Y
BOIFD20 & FD45 - for use as a ggarage fire door
- available as Z0 min. or 45 min. rating
- self closer is not included
SPD - for use only as a 'screened porch" door
- not for use to add to exterior door
- 2x4 jamb (IPO Zx6)
SPD w/GSL - same as SPD except:
- includes screen sidelite
Brass Package (single) - brass escutcheon
- brass knocker
- brass viewer
- brass kick panel
Brass Package (double) - as above except:
2 brass escutcheons Epp
- 2 brass kick panels (IPO 1)
63o FEATURES:
r" e01 zaso
1 72 36+2
r'OQ S`tE S9,2
71i• dsie - High Prmile aL•(m!n!(m �!il
612 762 1072 PVC -nndensa:e atannrt
s. �5
24++e 30 421 a - Standard Jamb[t idrn i
- Fusion IWded Pt'C D
V) Jasites Prin0rred A'(th:nter::,r
aiumtnum dame
- Double Tandem D+)n►Rilers
- Keyed Lock Unit
- Dnuoie Glazed Thermal
3 R Insulated Tempered Glass
- Fiberglass Mesh Screen
—roller bearing mounted
SLIDING - Heavy Duty compression
Iteatherstrtppin;
GLASS 'SG-5 OPMO S:
DOOR 868 982 i3is Frantc D+++r ash—:['(::; ,r
r t3 3334 38se 5+3x `andst.no
SYSTEMOQ�bar 838 982 '295 ',;,q^ ,i.;•.n—
'JCtr 37 3778 51
612 762 072 r,
241 6 30
3.
a n ^
s,a�c ;�aac
3'NA.•3,AHAi SNA.'A,RHM SWA-33i RHA
FEATURES:
I - Dnnr P2nels are:nsuiaw.
>:eei c•iad
- Fuil Nnmerer magnetic
' xeadters;r.a;ystem
Dot101e GiQZFa'Iterma(
insulated T-mpered Cear(;lass
- Brass Beres Glass BB):s
'�ERRACE It Triple ;lazed
_ __ _ •- _ c . E:+rG=4GM Cu'S CE BRASS
I
^Prs!ass :x::;r L•::tsCG^id
SWA' a':-A SNA-31L-A
wonI _ ...., . ...
SYSTEM
opnONS:
-ANO AC"'.E viEVVING ARCM CU'S;OE BRASS
Opening Specifications
FRAME SIZE
StelnAexrs Iff"Mm 7mnel
Odor Wn i W H W H
59+2. '9S e '509 x 2022
50' 2. '9se '816 . 2022
I
SUGGESTED ROUGH OPENING(S.R.0)
. _. ;.. ...._..__.i aw... an.. ,CA . J(1]s Note. ?h@ S.R.O.S Zn naw bW GtWM,nfp by the
fZ1� Ty P
rF ------- ---- -------------1�
I i
• r----- — --------------, -
I I I I
1 007 r rowan mR,vETE
a ro!m �_ -,
--————j L----- ----------- �_
T I I I I I
—————— ————————
�I 1zO rrwatoeR
I
cp I I
I I I I I S •I I I 6 p I I
I Me FLOORrash +r O.C. I +e moon JO,srs , O.C.
I ,ROW Da CRoss woDGNG ,row na CROSS BRIOG MG ,Cow 7)a CR0.45 e100GIRO I I I
PROVIDE
xa oonG�w
I I PONT LOAD$MOVE
I I I
6JI6 POST w PAD
I I I Ir QBToee3R I ar . eEneR i _I _ A ,o�IVJ I I
gyp%U.No.I I _ _ . .r +
I I $ I I 1
I I I I kI a I o I I
I S I r—'—, CRAWL SPACE I I
' --——————————� ' I l l I �0 4 I I
I
L---------------1.. I I
, I h �• � I e� I I
' •. 1 s. I I I I
L------ — I
I I ____J
` I i '• r---------------------
I I
I I
2 '- o"x 10 IS ETF-
'lEf'.TI GAIN
AI�T., BEN t�s.
(7 ) az'�
� z
4 c o" Poaiz. --
p'aon►Jv
will,
�ETAI L RW i
FOUNDATION PLAN,
Window and Door Schedule
Window/Door Insulation Values Refer to repective framing details for installation.
Thermo Pane(Pair Glass)with 1 coat Low"E",Air Filled R-3.2 RSI -0.56 Date: 11/14/00
Thermo Pane(Pair Glass)with 1 coat Low"E",Argon Filled R-3.9 RSI -0.69 Customer: KNOBLOCK,TERRY AND SHARON
Casement Window-Low"E",Air Filled U=.30 R-3.2 RSI -0.56 Order#: US250271
Casement Window-Low"E",Argon Filled U=.27 R-3.6 RSI -0.63 Model: THE SURFSIDE
Picture Window -Low"E",Air Filled U=.30 R-3.2 RSI -0.56
Picture Window -Low"E",Argon Filled U=.27 R-3.6 RSI -0.63
Slider Window -Low"E",Air Filled U=.35 R-2.7 RSI -0.48
Slider Window -Low"E",Argon Filled U=.32 R-3.0 RSI -0.52
Sliding Glass Door -Low"E",Air Filled U=.32 R-3.0 RSI -0.52
Sliding Glass Door -Low"E",Argon Filled U=.30 R-3.3 RSI -0.58
Insulated core, steel skinned door and sidelites
Core is polyurethane foam( Density 2.1 to 2.2 Ibs/cubic ft) R- 15.2 RSI -2.68
Note:Windows over bath tubs will automatically be tempered glass.
CODE QTY FRAME WIDTH X HIEGHT R.S.O WIDTH X HEIGHT M.O.WIDTH X HIEGHT #OF UNOBSTRUCTED OPENING VENTILATION GLAZING COMMENTS
INCHES(mm) INCHES(mm) INCHES(mm) OPTRS WIDTH X HIEGHT AREA AREA
REFER TO DTL#1047 INCHES(mm) SQ.FT(m2) SQ.FT(m2)
Coding Convention
(viewed from outside)
Casements windows.
C1942/2LF 1 39x41.5(990x1054) 39.75x42.125(1010x1070) 44x46.375(1118x1178) ONE 10.75x36(273x914) 3.47(0.312) 6.7(0.603) ILeft hinged operator,Right fixed.
C3036L 2 29.625x35.5(752x902) 30.375x36.125(771x918) 34.625x40.375(879x1025) ONE 20.5x30(521x762) 5.03(0.452) 4.92(0.443) Left hinged operator.
C304812LF 3 59.625x47.75(1514x1213) 60.375x48.375(1534x1229) 64.625x52.625(1641x1337) ONE 20.5x42.25(521x1073) 7.08(0.637) 13.86(1.247) lLeft hinged operator,Right fixed.Canadian and US Egress.
Picture awing and sliders.
PS3 1 35.5X67.375(902X1711) 36.25X68(921X1727) 40.5X72.25(1029X1835) ONE 30X10.75(762X273) 2.89(0.260) 12.22(1.1) Lower awing operator.Lower AND UPPER unitS tempered.
PS3 1 35.5X67.375(902X1711) 36.25X68(921X1727) 40.5X72.25(1029X1835) ONE 30X10.75(762X273) 2.89(0.260) 12.22(1.1) LOWER AWING OPERATOR,TEMPERED LEFT LOWER-TEMPERED RIGHT UPPER AND LOWER
PS3/21-F 1 71.375X67.375(1813X1711) 72.125X68(1832X1727) 76.375X72.25(1940X1835) ONE 30X10.75(762X273) 2.89(0.260) 24.44(2.12) Lower left operator right fixed.Lower units tempered.
LPS3/2LR 1 7;.375X67.375(1813X1711) 72.125X68(1832X1727) 76.375X72.25(1940X1835) ONE 30X10.75(762X273) 2.89(0.260) 24.44(2.12) Lower left HINGED operator.LOWER RIGHT HINGED OPERATOR.UNITS TEMPERED
Architectural windows.
2489 2 SEE DRAWING
2490 2 SEE DRAWING
2491 2 SEE DRAWING
_ DOORS.
VSG6-OF I 2 SEE ATTACHED
B01 DL 32 1 SEE ATTACHED