Loading...
HomeMy WebLinkAboutBLD2000-01503 SFR - BLD Permit / Conditions - 2/23/2001 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 1 Shelton, WA 98584 0`-'1 lip; RESIDENTIAL BUILDING PERMIT BLD2000-01503 OWNER: TERRY KNOBLOCH 253-841-2581 RECEIVED: 12/01/2000 CONTRACTOR: DOGWOOD CONSTRUCTI SITE ADDRESS: 21 E GARNET CT UNION ISSUED: 0 PARCEL NUMBER: 322327590011 EXPIRES: 08/23/2001 /23/2001 LEGAL DESCRIPTION: TR 1-A OF SURVEY 5/59, TR 1 OF SP#2688 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE NORTH ON BROCKDALE TO MCREAVY, LEFT ON UNION HEIGHTS DRIVE RIGHT ON UNION HEIGHTS PL NORTH TO GARNET, CORNER LOT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr.: V-N Type of Use: SF Insp. Area: No. of Bathrooms: 1 Occ. Group: R-3 Lot Size: Deck: 564 Type of Work: ACC Fire Dist.: 6 No. of Stories: 1 Occ. Load: Building:1,500 0 Valuation: $83,628 Buil ing Height: 16 Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline & Planning Information Make Length: Ft. Front: S 149.0 Ft. Shoreline: Ft. Water Body: Rear: N 52.0 Ft. Slope: 0.1 Ft. SEPA?: No Model: Width: Ft. Side 1: E 100.0 Ft. Shoreline Desig.: Year: Serial No.: Side 2: W 49.0 Ft. Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KLW 12/01/200 $550.39 55144 Hosebibs 2 Furnace<100K 1 Address Fee GMM 12/04/200 $15.00 55681 Kitchen Sink 1 Gas Outlets 2 Planning Review Fee SLO 01/12/200 $38.00 55681 Lavatories 2 Propane Tank 1 Public Works Review SLO 01/12/200 $32.19 55681 Showers 1 Ventilation Fan 3 Building State Fee MEC 02/05/200 $4.50 55681 Water Closets (Toilets) 2 WOodStove 1 Building Permit Fee MEC 02/05/200 $881.75 55681 Water Heaters 1 Dryer Vent 1 Mechanical Fee MEC 02/05/200 $117.75 55681 Bath Tubs 1 Mechanical Base Fee MEC 02/05/200 $23.50 55681 Clothes Washer 1 Plumbing Fee MEC 02/05/200 $75.00 55681 Plumbing Base Fee MEC 02/05/200 $20.00 55681 EH Plan Review PSD 02/14/200 $50.00 55681 Total $1,808.08 BLD2000-01503 Please refer to the following pages for conditions of this permit. 1 of 5 I CASE NOTES FOR BLD2000-01503 CONDITIONS FOR BLD2000-01503 1) This application i ject to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 2) The use, handling and storage of hazardo s materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X � 3) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work whi affect your project. X 4) Proposed structure or any portion thereof greater than 30" in height from gr a ine, must maintain a minimum of 5'setback from all property lines, easements and 10'from all County and State Road right of ways. X 5) All upland areas disturbed or ne reated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 6) All con ' ' ns and recommendations in the geo-assessment prepared by Bradley-Noble dated December 3, 2000 shall be followed. X� 7) The Mason County Resource Lands and Critical Areas Ordinance requires vegetative management of the site. There shall be a minimum disturbance of trees and vegetation in order to minimize erosion and stabilize Landslide Hazard Areas. Limbing trees for vie ur oses is preferred over tree removal. Vegetation removal on the slopes of banks shall be minimized due to the potential for erosion.X_ � BLD2000-01503 Please refer to the following pages for conditions of this permit. 2 of 5 8A Regulations which apply for GRADING of the site (per Mason County Resource Lands and Critical Areas Resource Ordinance): A..No grading shall be performed in Landslide Hazard Areas or slide prone areas prior to obtaining a grading permit subject to approval by the Director and based on recommendations contained in the geotechnical report with slope stability analysis and grading recommendations. B. Clearing, grading, and other construction activities shall not aggravate or result in slope instability or surface sloughing. C. Undergrowth shall be retained to the extent feasible. D. Clearing methods which minimize soil disturbance shall be used. E. No fill, dead vegetation (slash/stumps), or other foreign material shall be placed within a Landslide Hazard Area. X�/` 9) Site is located within an unstable Landslide Hazard Area. Development should be designed to preserve the natural drainage courses in the area. Surface drainage, including downspouts, shall not be directed onto or within 50 feet above or onto the face of a Landslide Hazard Area or it's associated buffer. If drainage must be discharged from the top of a Landslide Hazard Area to below it's toe, it shall be collected above the top and directed to below the toe by tight-line drain and provided with an energy dissipating device at the toe. X 10) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and must be collected by the Build* Department prior to any further inspections being performed or approvals granted. X y-57 11) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contr�qor fail to post the address on site prior to requesting inspections. 12) The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspects. X y�/1 13) The"approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval will not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and shall be collected by the wilding Department prior to any further inspections being performed or approvals granted. Y BLD2000-01503 Please refer to the following pages for conditions of this permit. 3 of 5 14) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air from e in accordance with the Uniform Mechanical Code. X 15) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee of$47.00 per hour(minimum 1 hour) will be charged and shalom collected by the Building Department prior to any further inspections being performed or approvals granted. 16) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occu=_ 1d result in permit revocation. X 17) Installation of heating equipment in single family residences shall meet the requirement of the 1991 WSEC. The furnace to be installed shall not exceed 150% of the heating design load or prescriptive requirements of Chapter 9. Furnace efficiency shall be .78 AFUE or higher. Ducts shall be taped, aled and mechanically fastened with a minimum of 3 fasteners per joint. Ducts shall be insulated to R-8. X 18) Proposed structure or any portion thereof greater than 30" in height from grade line, must maintain a minimum of 5'setback from all property lines, easements and 10' from all County and State Road right of ways. X� 19) All changes to "approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordin a or regulation, must be reviewed and approved by Mason County prior to construction. X 20) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. ' I 21) All property lines shall be clearly identified at the time of foundation inspection. X 22) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-co Mason County ordinances and building regulations. X ��� 23) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X �, BLD2000-01503 Please refer to the following pages for conditions of this permit. 4 of 5 This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before bui ing can be occupied. n OWNER OR AGENT: DATE: ? BLD2000-01503 Please refer to the following pages for conditions of this permit. 5 of 5 i CONCRIFtE MECHANICAL MOBILE HOME Footings-Setback date �,, -' &-"C( by Ribbons date Gas Piping date b Foundation Walls date by Set Up date by INSULATION date by 3G/S!AB Insulation Floors Final date by date by date by FfYkMING Walls FIRE DEPT. data /'(' by date by O_�t `��( by PLUMBING date OTHER Groundwork Attic date by datef'd'/� Z00/ by D.W.V. WALLBOARD NAILING date 6-V .?p(4 by date o -rG ZC;ty Water Line FINAL INSPECTION date - - r by — i date ty,Z by date by pl � �.�! � Sc'C �7.9iC' F ,�.eEL'�U.e� /L�i O•E/.�iT� 14 mat! Pi��SEp _ 1 � ��- �`' oot X 41110vvv LL'�*S &,Ue 4N /�r15✓yam �'� ZDoZ I January 6,2001 Mike: I have reviewed the Terry Knobloch Residence project,Permit#BLD2000-01503 and I find the following items that need correction. 1. The lot dimensions are not given on the site plan. 2. No elevations are given on the topographical cross section or the site plan. 3. There was no energy information with the submittal and no heat source was specified. Therefore the energy calculations could not be checked. 4. The engineering could not be verified because there is nothing on the engineering calculations to indicate what snow load had been used. There was a reference on the plans to 251b snow loads but not on the stamped engineering. It should be noted that none of the structural loads have been checked. I did, however show the tributary loads on the roof beams and major headers assuming a 25 lb snow load. 5. A soil bearing of 2,000 P.S.F.was assumed on the plans. UBC Table 18-1-A requires that 1,500 P.S.F. be used for sandy soils unless data is provided to indicate otherwise. No such data was provided. 6. The kitchen area is completely blank. I assumed the usual equipment and used that for permit valuations. 7. No grade and species were given other than"Group III "framing material. I have completed the as ch of the review as possible. The plan is NOT approved. Th u, She an CodePro onsulting PERMIT NO.: BLD MASON COUNTY I BUILDING PERMIT APPLICATION t I � 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968 APPLICANT INFORMATION CONTRACTOR INFORMATI0 1 Owner`-escIpT &yr gAw gtJo S .#C H Contractor Name nQ9 ID c Mailing Address /' a A -nd AuE. G . Mailing Address E I& W 15 t City&u V.4LLV4 State LM&Zip Code q 13 7S" City 0"1 D V'1 State Zip Code Phone(Z SLI) 4141.258/ Othe U rPh. Ph.( 3(0 ) 8 */ i ther Ph.( 8 Lien/Title Holder1. v LoG Contractor Reg # OC,*0 0Address /7 9 Id Expiration o?Dp SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic Existing Septic_)L_Connect to Sewer System Name of Sewer System Well Water System Name of Water System p to in f PARCEL INFORMATION-12 digit Tax Parcel No. 37 2 3 2. /1.�/ c7ad Z Fire District �y Legal Description Site Address(Please include street name, street n ber and city) Directions to site - N'f //fX�kfs A. NI�f�1 ,� �IF9AO.vFTr fod���LvT Will timber be cut and sold in parcel preparati6ril (Yes/No)_ALdL_ Is your property within 200' of the following: Body of Water(Name) Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream YSlopes or Bluffs PERMANENT RESIDENCE❑ SEASONAL RESIDENCE❑ TYPE OF JOB New_)(,_Add Alt Repair Other Use of Building Describe Work e-4.0,45t No. of Bedrooms-4Nc; of Bathrooms :1 SQUARE FOOTAGE-1 st Floor/5p d 2nd Floor 3rd Floor Loft Basement Deck Other sq. ft. Garaig ,!__)(__Attached_jrDetached Carport Attached Detached MOBILE HOME INFORMATION-Make Model Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Prioe $ Replacement Unit ?(Yes/No) Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I c<ify that I am exenVt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration`4aw RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the wotR for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval, Date X / , U� Date 110 FOR OFFICIAL USE BEYOND THIS POIN_T.l Accepted by Date Su Ittal Amount Due Receipt N� DEPARTMENT,AI»,RE1/I W APPROVED, DENIED' CONDITION CODES Building Departmm ,� Occ GroupIE^ T e C nst Planning Department Environmental Health Department Public Works Department Fire Marshal Valuation $ FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing&Base Fee Planning Review Fee Mechanical&Base Fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal ( ) TOTAL FEES Fie: ALL icer� 1✓��,-� oA�: 1 Subiect to Change Without Notice FEBRUARY 5. 1993 - EXTERIOR DOORS owl gal an sol 804 Sod 807 all Ala A14 r � 4; %1 - i ii it i ii 711 4 ,>ZIIfO am I Tim ! WU I Xm 1iJ0 � ety ass re a�pligue Gulls included on Bab, B18, A14 Jambs for 2x6 wall Deadbolt lock & passage set Door swings in b - door swims out 2x4 jamb UP(T 2x6) - key to knob (IPO deadbolt & passage) - for use as a garage service door only Y BOIFD20 & FD45 - for use as a ggarage fire door - available as Z0 min. or 45 min. rating - self closer is not included SPD - for use only as a 'screened porch" door - not for use to add to exterior door - 2x4 jamb (IPO Zx6) SPD w/GSL - same as SPD except: - includes screen sidelite Brass Package (single) - brass escutcheon - brass knocker - brass viewer - brass kick panel Brass Package (double) - as above except: 2 brass escutcheons Epp - 2 brass kick panels (IPO 1) 63o FEATURES: r" e01 zaso 1 72 36+2 r'OQ S`tE S9,2 71i• dsie - High Prmile aL•(m!n!(m �!il 612 762 1072 PVC -nndensa:e atannrt s. �5 24++e 30 421 a - Standard Jamb[t idrn i - Fusion IWded Pt'C D V) Jasites Prin0rred A'(th:nter::,r aiumtnum dame - Double Tandem D+)n►Rilers - Keyed Lock Unit - Dnuoie Glazed Thermal 3 R Insulated Tempered Glass - Fiberglass Mesh Screen —roller bearing mounted SLIDING - Heavy Duty compression Iteatherstrtppin; GLASS 'SG-5 OPMO S: DOOR 868 982 i3is Frantc D+++r ash—:['(::; ,r r t3 3334 38se 5+3x `andst.no SYSTEMOQ�bar 838 982 '295 ',;,q^ ,i.;•.n— 'JCtr 37 3778 51 612 762 072 r, 241 6 30 3. a n ^ s,a�c ;�aac 3'NA.•3,AHAi SNA.'A,RHM SWA-33i RHA FEATURES: I - Dnnr P2nels are:nsuiaw. >:eei c•iad - Fuil Nnmerer magnetic ' xeadters;r.a;ystem Dot101e GiQZFa'Iterma( insulated T-mpered Cear(;lass - Brass Beres Glass BB):s '�ERRACE It Triple ;lazed _ __ _ •- _ c . E:+rG=4GM Cu'S CE BRASS I ^Prs!ass :x::;r L•::tsCG^id SWA' a':-A SNA-31L-A wonI _ ...., . ... SYSTEM opnONS: -ANO AC"'.E viEVVING ARCM CU'S;OE BRASS Opening Specifications FRAME SIZE StelnAexrs Iff"Mm 7mnel Odor Wn i W H W H 59+2. '9S e '509 x 2022 50' 2. '9se '816 . 2022 I SUGGESTED ROUGH OPENING(S.R.0) . _. ;.. ...._..__.i aw... an.. ,CA . J(1]s Note. ?h@ S.R.O.S Zn naw bW GtWM,nfp by the fZ1� Ty P rF ------- ---- -------------1� I i • r----- — --------------, - I I I I 1 007 r rowan mR,vETE a ro!m �_ -, --————j L----- ----------- �_ T I I I I I —————— ———————— �I 1zO rrwatoeR I cp I I I I I I I S •I I I 6 p I I I Me FLOORrash +r O.C. I +e moon JO,srs , O.C. I ,ROW Da CRoss woDGNG ,row na CROSS BRIOG MG ,Cow 7)a CR0.45 e100GIRO I I I PROVIDE xa oonG�w I I PONT LOAD$MOVE I I I 6JI6 POST w PAD I I I Ir QBToee3R I ar . eEneR i _I _ A ,o�IVJ I I gyp%U.No.I I _ _ . .r + I I $ I I 1 I I I I kI a I o I I I S I r—'—, CRAWL SPACE I I ' --——————————� ' I l l I �0 4 I I I L---------------1.. I I , I h �• � I e� I I ' •. 1 s. I I I I L------ — I I I ____J ` I i '• r--------------------- I I I I 2 '- o"x 10 IS ETF- 'lEf'.TI GAIN AI�T., BEN t�s. (7 ) az'� � z 4 c o" Poaiz. -- p'aon►Jv will, �ETAI L RW i FOUNDATION PLAN, Window and Door Schedule Window/Door Insulation Values Refer to repective framing details for installation. Thermo Pane(Pair Glass)with 1 coat Low"E",Air Filled R-3.2 RSI -0.56 Date: 11/14/00 Thermo Pane(Pair Glass)with 1 coat Low"E",Argon Filled R-3.9 RSI -0.69 Customer: KNOBLOCK,TERRY AND SHARON Casement Window-Low"E",Air Filled U=.30 R-3.2 RSI -0.56 Order#: US250271 Casement Window-Low"E",Argon Filled U=.27 R-3.6 RSI -0.63 Model: THE SURFSIDE Picture Window -Low"E",Air Filled U=.30 R-3.2 RSI -0.56 Picture Window -Low"E",Argon Filled U=.27 R-3.6 RSI -0.63 Slider Window -Low"E",Air Filled U=.35 R-2.7 RSI -0.48 Slider Window -Low"E",Argon Filled U=.32 R-3.0 RSI -0.52 Sliding Glass Door -Low"E",Air Filled U=.32 R-3.0 RSI -0.52 Sliding Glass Door -Low"E",Argon Filled U=.30 R-3.3 RSI -0.58 Insulated core, steel skinned door and sidelites Core is polyurethane foam( Density 2.1 to 2.2 Ibs/cubic ft) R- 15.2 RSI -2.68 Note:Windows over bath tubs will automatically be tempered glass. CODE QTY FRAME WIDTH X HIEGHT R.S.O WIDTH X HEIGHT M.O.WIDTH X HIEGHT #OF UNOBSTRUCTED OPENING VENTILATION GLAZING COMMENTS INCHES(mm) INCHES(mm) INCHES(mm) OPTRS WIDTH X HIEGHT AREA AREA REFER TO DTL#1047 INCHES(mm) SQ.FT(m2) SQ.FT(m2) Coding Convention (viewed from outside) Casements windows. C1942/2LF 1 39x41.5(990x1054) 39.75x42.125(1010x1070) 44x46.375(1118x1178) ONE 10.75x36(273x914) 3.47(0.312) 6.7(0.603) ILeft hinged operator,Right fixed. C3036L 2 29.625x35.5(752x902) 30.375x36.125(771x918) 34.625x40.375(879x1025) ONE 20.5x30(521x762) 5.03(0.452) 4.92(0.443) Left hinged operator. C304812LF 3 59.625x47.75(1514x1213) 60.375x48.375(1534x1229) 64.625x52.625(1641x1337) ONE 20.5x42.25(521x1073) 7.08(0.637) 13.86(1.247) lLeft hinged operator,Right fixed.Canadian and US Egress. Picture awing and sliders. PS3 1 35.5X67.375(902X1711) 36.25X68(921X1727) 40.5X72.25(1029X1835) ONE 30X10.75(762X273) 2.89(0.260) 12.22(1.1) Lower awing operator.Lower AND UPPER unitS tempered. PS3 1 35.5X67.375(902X1711) 36.25X68(921X1727) 40.5X72.25(1029X1835) ONE 30X10.75(762X273) 2.89(0.260) 12.22(1.1) LOWER AWING OPERATOR,TEMPERED LEFT LOWER-TEMPERED RIGHT UPPER AND LOWER PS3/21-F 1 71.375X67.375(1813X1711) 72.125X68(1832X1727) 76.375X72.25(1940X1835) ONE 30X10.75(762X273) 2.89(0.260) 24.44(2.12) Lower left operator right fixed.Lower units tempered. LPS3/2LR 1 7;.375X67.375(1813X1711) 72.125X68(1832X1727) 76.375X72.25(1940X1835) ONE 30X10.75(762X273) 2.89(0.260) 24.44(2.12) Lower left HINGED operator.LOWER RIGHT HINGED OPERATOR.UNITS TEMPERED Architectural windows. 2489 2 SEE DRAWING 2490 2 SEE DRAWING 2491 2 SEE DRAWING _ DOORS. VSG6-OF I 2 SEE ATTACHED B01 DL 32 1 SEE ATTACHED