Loading...
HomeMy WebLinkAboutBLD2010-00493 Carport to Garage - BLD Permit / Conditions - 9/1/2010 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 NI Shelton,WA 98584 P,$ RESIDENTIAL BUILDING PERMIT BLD2010-00493 OWNER: STEVE LEVETTE RECEIVED: 6/17/2010 CONTRACTOR: LICENSE: EXP: ISSUED: 9/1/2010 SITE ADDRESS: 30 E MADRONA BEACH LN UNION EXPIRES: 3/1/2011 PARCEL NUMBER: 322325400009 LEGAL DESCRIPTION: MADRONA INC TR 9 &T.L. PROJECT DESCRIPTION: DIRECTIONS TO SITE: CHANGING CARPORT TO ENCLOSED GARAGE ST RT 106 (UNION) L ON MADRONA BEACH LN TO SITE ADDRESS ON 8.31.2010: Demolished old structure, construct new garage in same THE RIGHT SIDE footprint General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: Type of Work: ACC Fire Dist.: 6 No. of Stories: 1 Occ. Load: Building: Garage-Attached 587 Valuation: Building Height: 16 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information : y Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: Model: Width: Ft. Rear: Ft. Slope: Ft. Shoreline Desi Side 1: Ft. g.. Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee TW 6/17/2010 $126.91 S12010000 Building State Fee LDK 7/7/2010 $4.50 S12010000 Building Permit Fee LDK 7/7/2010 $195.25 S12010000 Plan Check Fee DLC 8/31/2010 $236.11 S12010000 ADJUST--Building Permit Fee DLC 8/31/2010 $168.00 S12010000 BLD-Plan Copies DLC 9/1/2010 $4.50 S12010000 Total $735.27 BLD2010-00493 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2010-00493 CONDITIONS FOR BLD2010-00493 1) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X ; 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X Si 3) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 4) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 5) Any changes in proposed construction prescribed by the engineer of record, RES Engineering, shall be reviewed and approved by the engineer of record and submitted in writing to the Mason County Building Department prior to making changes. All engineering documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. x _, I, 6) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building X soect'r shall be made prior to requesting additional inspections. BLD2010-00493 Please referto the following pages for conditions of this permit. 2 of 4 7) - All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason ounty ordinances and building regulations. X L 8) The use, handling and storage of haz rdous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X "-)� 9) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X t`�[- 10) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 11) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 12) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 4L 13) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X sr6I, 14) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-802-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X � % 15) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 16) Per IRC -SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in acc rdance with the applicable provisions of this section and the manufacturer's installation instructions. X � (� BLD2010-00493 Please referto the following pages for conditions of this permit. 3 of 4 17) , This project, modified and approved on 8/31/2010 inludes the demolition of the existing carport and construction of a garage in the same footprint. Trusses shall be designed in accordance with engineer of record specifications such that trusses be designed to be supported mid span as well as at their ends in order to address loading on the existing foundation system. Walls shall be framed with 4x4 posts, 4-ft oc at side walls and 44 posts at roof mid-span to support girder. The first inspection shall be performed after all framing elements have been completed, Labor& Industries has approved the electrical permit for cover, and the structure is weathered in. During the framing inspection the inspector will verify that the gypsum wallboard on the exterior of the structure, required for the 1-hour assembly due to property location, is installed correctly. X L x 18) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the XuildinD e partment prior to any further inspections being performed or approvals granted. 19) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved. X 1_ 20) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use perm) shall be applied for, reviewed and approved prior to the change. X (� 21) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROAD WAY. X r if construction or work is suspended for period of 180 days at an time after work is This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,o p p Y Y commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described grope and structure for review 5andn pection. OWNER OR AGENT: DATE:_-r / V I BLD2010-00493 Please refer to the following pages for conditions of this permit. 4 of 4 to o CONCRETE MECHANICAL MANUFACTURED HOME M oDate By _w.-_.. -- —• .0 o Footings/Setbacks Gas Piping Ribbons � o Interior Date By Interior"Date By Date By m Exterior Date By Exterior-Date By Set-up Cl) Point Load!Isolated Footings INSULATION Date By '{ Date By Da d By SLAB INSULATION FIRE DEPARTMENT m Foundation Wails Floors Date By Date By Data _ _ By DECKS F RAM I NG Wails Date By Date Li Gt By Data ___ By PROPANE TANKS PLUM if Vault Date By Date By OTHER Groundwork Attic Date By Type. Dale By Date By D.W.V DRYWALL Type- Int.Brace Wall Date By IA Date BY Date By FINAL INSPECTION Fire Se ration tV Water Line Pe C Dale By Date By Date vy By O m � Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments J,0 0'/j q jr) b& s, v <n m En m a,r� i C�vc�� �jC �� de �- rle i J E rn' ��-� T-G•( I O "1 �r3 !0 N r© cp}� l�r ► �� t"t✓ d�--�r�c�YL. 1 4 tTz. " 0 J �� f�i`•�.�'«"-,i �� t^'..� `�`�:.,� ,rr � ..d•.. .fit � k # "` � ��• _ , - A �r 4 , gg �P Y 4. ya m , r i �4 s; ry di T. ..- a?fib. _� ,♦ � � w r { �p a . � 1 � t I S 11 AS In i 10 lb• : y � - � y.n`.aAl. 2 'jai• '� �.�. t ed { IgN t { ,• sr ._,.. i.�' a t .yL� ty.°L'Jh',Lr�"Z't�jy.k� L� r�a- pi lip OL � - it d i �,t ii► tt�. w ^�1 M ' Page 1 of 1 Debbera Coker- Permit# BLD2010-00493 Levette Garage From: Levette <levette@hctc.com> To: <dlc@co.mason.wa.us> Date: 8/19/2010 9:53 AM Subject: Permit# BLD2010-00493 Levette Garage oil .r a IMG_4266.JPG S file://C:\Documents and Settings\Dlc\Local Settings\Temp\XPgrpwise\4C6CFF12Masonmai110017035701... 8/24/2010 Page 1 of 1 Dtbbera Coker- Permit# BLD2010-00493 Levette Garage From: Levette<levette@hctc.com> To: <dlc@co.mason.wa.us> Date: 8/19/2010 9:54 AM Subject: Permit# BLD2010-00493 Levette Garage .......... ` C ipl t e r u i e v: w.. a ad .' 1�4S'r i v IMG_4268.JPG C� file://C:\Documents and Settings\Dlc\Local Settings\Temp\XPgrpwise\4C6CFF6CMasonmai110017035701... 8/24/2010 I Page 1 of 1 Debbera Coker- Permit# BLDG 2010-00493 Levette garage From: Levette <levette@hctc.com> To: <dlc@co.mason.wa.us> Date: 8/24/2010 8:44 AM Subject: Permit# BLDG 2010-00493 Levette garage An r r ,TE , w i I' e _ t , n ➢ P f Debbera, picture of old carport with old curbing and old 4X4 posts. North side r' file://CADocuments and Settings\Dlc\Local Settings\Temp\XPgrpwise\4C73866CMasonmai110017035701... 8/24/2010 Page lo! Dabbef Coker- Perm)# 2010-00493 Levee Garage From: Lv tt 4ee eghdcc m> To: <egc.mas m«a us Date: 8/2»O]0aa7AM Subject: Permit#2010 0 493 L v tt Garage \ �\ . . % \, ` l �»- . j�«<\2 . a , . axe . \-0000\a ° . DebbeC picture of Soutside old Carport partial wall and curbing 61:/C§Do ume bad Scttln ADIQto al Sctfina6Temp\r/rpwls\C738711Ma onm310017 35701E, 8 2%010 Page 1 of I Debbera Coker- Levette Garage Permit#2010-004493 From: Levette<levette@hctc.com> To: <dlc@co.mason.wa.us> Date: 9/22/2010 8:39 AM Subject: Levette Garage Permit#2010-004493 Hi, Debbera, This is the nail pattern from the exterior south wall corner(southwest corner). Thank you, Barbara i CA .4 s N IMG 4599.JPG file://C:\Documents and Settings\Dlc\Local Settings\Temp\XPgrpwise\4C99COBOMasonmai110017035701... 9/22/2010 EXISTING HOUSE WALL I ' i ` S-O" DOOR J"X12" ANCHOR BOLT AT 4' O.C. f 2'-0"O.C. SPACING - ALTERNATE 2"X4" i AND 4"X4" POST ' ,,,-CEDAR SIDING I �✓ ONCRETE WALL N O GYP. BOARD p I APOR BARRIER ——————————— ————— —— — 2"X6" AT 24" b.C. "X6" POST 0'-0" X 8'-0" 4"X6" POST C OVERHEAD DOOR "X6" STUD WALL t SCALE: 1 /4 —o$P ��� 'r cq�(..t-cxP Irk, , AV Request To Revise An'Approved Plan Permit Number: BLDP 6 Name Lp- P";?,it t-e-, Parcel Number - - Phone Number daytime (,�( G ) 9 - 796 Project Address Mailing Address 9 D - S 35"S Please provide a complete, detailed description of the proposed rev'si ns to the approved plans: _ 2s - -7 , 3 Jl8! Are two sets of the revised plans or addendum indicating the changes included? ❑ Yes ❑ No Are the approved site plans included? ❑ Yes ❑ No Are the revisions clearly and accurately identified on the plans or addendum? Q Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? ❑ Yes ❑ No If Yes,Has the engineer or architect approved this revision? ❑ Yes ❑ No Is a stamped and signed approval included with this request? ❑ Yes ❑ No Wote:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record.) Does the proposed revision modify the footprint or location of the structure? ❑ Yes ❑ No If Yes, Is a revised site plan, with all new setback dimensions included with this request? ❑ Yes ❑ No Additional Information: Applicant's signature Date: j Office Use Only Received by: Date Sent Assigned To Approved By Date ��� � ❑ B. Original Valuation: yy� $ /O Additional Valuation: ❑ P. Sq.Ft. x$ 07 $ Sq.Ft. x$ $ ❑ E.H. Total New Valuation ❑ P.W. Additional Fees: / AdditionalglanningDepS___ - �. _ . Additional Plan Review $ / Additional Condition /Comments: `2 Additional Building Permit $ leo S,. O Additional Plumbing $ Additional Mechanical $ 42 3 , Additional E.H. Dept. $ Other $ 1 J Total Amount Due: $ J Amount To Be Paid Up-Front$