HomeMy WebLinkAboutBLD2003-00173 Rockwall - BLD Permit / Conditions - 3/24/2003 I inspection Line(360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352
Mason County Bldg. 3 426 W. Cedar P.O. Box 186
Shelton,WA 98584
RESIDENTIAL BUILDING PERMIT BLD2003-00173
OWNER: JOSE FLORES RECEIVED: 2/24/2003
CONTRACTOR: LICENSE: EXP: ISSUED: 3/24/2003
SITE ADDRESS: 143 E SPRUCE ST UNION EXPIRES: 9/24/2003
PARCEL NUMBER: 322325218004
LEGAL DESCRIPTION: UNION-GRAYS HARBOR& UCRR ADD BILK: 18 LOTS 3-4 & N1/2 ALLEY ADJ
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
ROCKWALL
General Information Construction&Occupancy Information Square Footage Information
No.of Bedrooms: Type of Constr.:
Type of Use: Insp.Area: No.of Bathrooms: Occ. Group: Lot Size: Deck:
Type of Work: Fire Dist.: No.of Stories: Occ. Load: Building:
Valuation: Building Height: Occ. Status: Basement:
Manufactured Home Information Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: N 70.0 Ft. Shoreline: Ft. Water Body:
Rear: S 5.0 Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Side 1: W 40.0 Ft. Shoreline Desig.: Not Applicable
Year: Serial No.: Side 2: E 36.0 Ft. Comp. Plan Desig.: Rural Activity Ctr.
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty, Type By Date Amount Receipt
Plan Check Fee KLW 2/24/2003 $43.03 2710
Building State Fee MRG 2/28/2003 $4.50 62316
Building Permit Fee MRG 2/28/2003 $66.20 62316
Total $113.73
BLD2003-00173 Please refer to the following pages for conditions of this permit. 1 of 4
` CASE NOTES FOR
• BLD20 0 3-00 1 73
CONDITIONS FOR
BLD2003-00173
-n� 1) This application is subject to Buffer and Landscaping requirements as established under Mason County Ordinance
1.03.036.X
2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
/ Y
3) The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of
J the Mason County Fire Marshal. X
4) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
X
5) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Department prior to any further inspections being performed or approvals granted.
X
6) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and
legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site
inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or
contractor fail to post the address on site prior to requesting inspections.
X
BLD2003-00173 Please refer to the following pages for conditions of this permit. 2 of 4
7) ' The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable)are part of the approved plans and must
remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they
shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of
. plans on site for the duration of the project.- Failure to comply and/or removal of approved documents will result in failure of required building inspections.
X
8) The "approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"plot plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
X
9) All changes to"approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordinance
or regulation, must be reviewed and approved by Mason County prior to construction.
X
�C
10) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall be made prior to requesting additional inspections.
X
t+� 11) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County" ordinances and building regulations.
X
12) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prevented action from being taken. No more than one extension may be granted.
X
13) Approved per dimensions and setbacks on submitted site plan. X
�\14) All areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or
straw matting). X
A 15) The corner of the rock wall closest to the residence is determined to be 4' 1". The rock wall wraps around the garage and progressively diminishes in
height along the eastern and southern portions of the wall. The height of the south corner of the wall is approximate) 2'5". Because the southern portion
I � Y
of the rock wall, ranges in height from 3'to 2'5", and is located within the 5'setback of the property line, the planning department considers this as rockery
landscaping and allowed in setback without DR variance. Any changes to approved site plan will require prior planning review.
BLD2003-00173 Please referto the following pages for conditions of this permit.Pe 3 of 4
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is
commenced. Evidence of co 'nuation of work is a progress i tion within the 180 day period. Final inspection must be approved before building can be occupied.
OWN ER OR AGENT: DATE:
6/
BLD2003-00173 Pease refer to the following pages for conditions of this permit. 4 of 4
W
o '
o CONCRETE MECHANICAL MANUFACTURED HOME
0
GO Footings / Setbacks Date By Ribbons
0
D ate B y Gas Piping Date B y
~ Foundation Walls Date B y Set-up
w
Date By INSULATION Date By
B G / Slab Insulation Floors Final
Date By Date By Date By
FRAMING Walls FIRE DEPT
Date By Date By Date By
PLUMBING Attic OTHER
Groundwork Date By
Date By WALLBOARD NAILING
D.W.V. Date By
Date By FINAL INSPECTION
Water Line Date3/3/k By J
Date By Date By
CD
CD
C
a
0
v
a
8
a
o
o
M O
CD
j o
O O
O
W �
0
MASON COUNTY PERMIT NO. BLD� 'W 1 ( 3
BUILDING PERMIT APPLICATION
426 W.Cedar/P.O.Box 186,Shelton,WA 98584
Shelton(360)427-9670 Belfair(360)275-4467 Elma(360)482-5269 Seattle(206)464-6968
On the Web www.co.mason.wa.us
APPLICANT 1(,FORMATION CONTRACTOR INFORMATION
Owner p S 4 4J 'L OQ E C Contractor Name
Mailing Address f _ f?-t ' '(� Mailing Address
City U A),C)4) State 1 Zip Code City State Zip Code
Phone cj TJY- // !'Other Ph. L___) Phone L_J Other Ph. (___)
Lienrl-itle Holder Contractor Reg.# Exp.
E-mail Address E-mail Address
SEPTIC/WATER SYSTEM INFORMATION -Connect to New Septic Existing Septic Connect to Sewer
System_Name of Sewer System Well p- Water System
Name of Water System
PARCEL INFORMATION- 12 digit Tax Parcel No. / / Fire District l`
Legal Description )�. I �K ,! U I
Site Address (Please include street name,street number and city) y.�
Directions to site
Will timber be cut and sold in parcel preparation? (Yes/No)
Lake River/Creek Pond Wetland Seasonal Runoff Stream
,Slopes or Bluffs
PERMANENT RESIDENCE❑ SEASONAL RESIDENCE❑
TYPE OF JOB- New Add Alt Repair Other Use of Building
Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action? (Yes/No)
Describe Work
No.of Bedrooms N"Bathrooms SQUARE FOOTAGE- t Floor — .2nd Floor
3rd Floor_Loft ', Basements Deck Other sq.
Garage Attached Detached Carport Attached Detached
MOBILE HOME INFORMATION- Make Model Model Year
Length Width Serial No. No.of Bedrooms No.of Bathrooms
Type of Heat Purchase Price$ Replacement Unit? (Yes/No)
Installer Name Certification No.
NOTICE:THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF
CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION.The owner or agent on owner's behalf,represents that the
information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection
of this project.Owner/Builder acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgment
of such is by signature below:
OWNER AFFIDAVIT-I certify that I am exempt from the requirements of CONTRACTOR'S AFFIDAVIT-I cer tIEtQE gistered as a
the Contractor Registration Law RCW 18.27 and am aware of the ordi- contractor in the State of Washington and that I am aW the ordinance
nance requirements for which this permit is issued and that all work will be requirements regulating the work for t�ls,�permit is issued and all
done in conformance therewith. No ch es shall be made without first work shall be done in conformance there d .N`S ct 3s shall be made
obtaining-approval. without first obtaining approval.426 W
X ( 1� Date X CED Date An T`
FOR OFFICIAL USE BEYOND THIS POINTG
ccepUW by I Date . ; . Submittal Amount Due �` Receipt No.01
C/
Building Department J n
Occ Group Type Constr. ('
Planning Department
Environmental Health Department
Public Works Department
Fire Marshal
Valuation$
FEES
Building Permit Fee Site Inspection
Plan Review Fee EH Review Fee
Plumbing &Base Fee Planning Review Fee
Mechanical & Base Fee Other
Wood/Gas/Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal ( )
TOTAL FEES
zop
- "7 � /20 e ' �-e d-S
w
r r A-d -A16,z-A, o�
f
w1 L.�.,�,�.-[t aC � a.-� - ��01.•� �,-� ram.
r, r
't
c
y
�`.•"� �`"� boa - v�YS _
^�e.d 6.�'�D�'�'S lox.-�-r � • /��,;...�� �J��c=C,,
- VK WALL --
ONT/NUOUS CONCf?E rE GAP gL 4 PW TO E>CTENO TO OAYL/GrHT
�" THICKNESS GLASS C CONCRETE � _
�EGW/RED FOR (1JALLS 6' OR '
�REArER IN HEIGrHr
24" MIN
h4:
l'•'•.94'..1.1 •.,{•..... NArU
—sL OPT As 11XNECEssARY FOF
sTABILIrY BUR/Na
WALL BACKP/L L
I'=/L TIER FABRIC
12 MIN.
/.
ALL
LOGAr/ON
F/N/SI-1 Gl¢4DE
SLOPE -51r MAX.
PLACE ROCK ON F/Rl•1 UND/sTEf?BEG SOILS
OR ON CONCRrETE' fJASE
B
SE�. REFElQRALS ARE TO
!LS•-14:;)T SrANDARn SPEC/P/CATIONS
ROCKER�' M/N/l`9UM ROGfG
{L- ka-4f 7` /N RECEIVED
IN A LEj5T
�N> «� FEB 14 2003
rd-6 1.3
426 W. CEDAR ST.,
-!1 2.�
12-14 3.,a
NOrE, 14' /s MAX. 4LL000A®LE• HEIGHT FIGURE 3
I