HomeMy WebLinkAboutPAR2019-00038 - PAR Letters / Memos - 7/15/2019 1
MASON COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
Building Division
Mason County Bldg. 8, 615 West Alder Street, Shelton, WA 98584
www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269
MASON COUNTY PRE-SUBMISSION CONFERENCE NOTES
• BUILDING DEPARTMENT REPRESENTATIVE: Tricia Woolett
(360) 427-9670 ext. 281
E-Mail: tw@co.mason.wa.us
• DATE: July 1511 @ 9:30 AM
• PROJECT/ PROJECT TRACKING NUMBER: PAR2019-00038
• PARCEL NUMBER: 12220-50-72009 TO BE KEPT IN THE
• SITE ADDRESS: Corner of Lakeland and WA 3 PARCEL FILE
• PROJECT REPRESENTATIVE (S): Larry Grohn 360.876.7885
DESCRIPTION & SIZE OF PROJECT/OCCUPANCY CLASSIFICATION & USE: Installation of new drive up
interactive teller machine. The work is exterior modification of existing parking lot to include a curb island
an enclosure for the new drive up unit.
ALL COMMERCIAL SUBMITTALS ARE BY APPOINTMENT.
PLEASE CALL 360.427.9670 EXT. 352 TO SCHEDULE A APPOINTMENT.
COMMENTS: Plans need to include compliance notes and specification for WSEC Table
C406.5.5(2) for lighting zone 2 per table C405.5.2(1).
THE FOLLOWING MUST BE INCLUDED ON THE PLANS:
• SETBACKS TO PROPERTY LINES: Provide a site plan, drawn to scale. Clearly identify all
structures including fences, parking and other similar items, with setback dimensions on site the
plan.
• DISTANCES TO OTHER STRUCTURES: Site plan, drawn to scale shall clearly identify distances,
where required include fire-resistive details, including continuity, &tested assembly details.
• FIRE RESISTANCE FOR EXTERIOR WALLS: When applicable include fire-resistive details,
including continuity, &tested assembly details.
• IDENTIFY TYPE OF CONSTRUCTION & PROVIDE ALLOWABLE AREA CALCULATIONS WHERE
NEEDED. See Chapter 5, IBC
• FIRE-RESISTIVE RATED CONSTRUCTION &TYPE OF CONSTRUCTION: Where required
demonstrate compliance. Identify the location of the assembly, compliance to continuity
requirements and construction details:
Exterior Wall (IBC704), Fire Wall (IBC705), Fire Barrier (IBC706), Shaft Enclosures (IBC 707), Fire
Partitions (IBC 708), Smoke Barriers (IBC 709), Smoke Partitions (IBC 710), Horizontal
Assemblies (IBC 711), Penetrations (IBC 712), Fire Resistant Joint Systems (IBC 713), Fire-
Resistance Rating of Structural Members (IBC 714), Opening Protection (IBC 715), Duct and Air
Transfer Openings (IBC 716), Concealed Spaces (IBC 717), ETC,
• ENGINEERING REQUIRED: Structures that do not comply with prescriptive specifications of the
2015 International Code (IBC) shall be designed in accordance with Chapter 16 of the IBC.
Referencing Washington State RCW 18.08.410 - Structures 4000 sq. ft or more shall have all plan
pages reviewed and stamped by a Washington State licensed design professional. The review
shall include a code evaluation addressing life-safety, plumbing & mechanical evaluation, and
structural analysis. (ref. RCW 18.08.410) ALL PLAN PAGES SHALL BE STAMPED AND SIGNED
BY THE DESIGN PROFESSIONAL, including plumbing and mechanical pages.
• ACCESSIBILITY REQUIRED: YES, must include compliance information and plan details including
design details and analysis demonstrating compliance to Chapter 11 and details demonstrating
compliance to ANSI 117.1, in effect at the time of submittal. Include information demonstrating
compliance for restrooms, employee work areas, parking spaces, accessibility to structure,
drinking fountain, signage, etc. Construction plans will NOT be accepted without compliance
details include on the plans.
• NON-RESIDENTIAL ENERGY CODE (IECC/WSEC): Provide completed compliance forms.
Forms (Envelope, Mechanical and Lighting are available at: https://wseccomplliancedocuments.com/
• SPECIAL INSPECTION: Referencing IBC Chapter 17, Section 1704.1.1. When required a Statement
of Special Inspections must be prepared by registered design professional in responsible charge.
A completed Special Inspection Agreement form must be submitted prior to permit issuance.
• MECHANICAL EQUIPMENT: Identify the location and type of mechanical equipment located within,
and outside the structure. Address foundation and support systems for equipment. Where new
equipment will be placed on site provide UL listing information and/or construction details shall be
stamped by a Washington State licensed design professional. Where applicable include duct
information and duct support compliance information.
• FIRE MARSHAL REQUIREMENTS: Fire Marshal comments requirements including fire protection
requirements and identify compliance information on the proposed building plans. Show the
location of fire extinguishers and identify type. The following items must be completed for the
project approval:
• EMERGENCY VEHICLE ACCESS: "Standards for Fire Apparatus Access Roads: adopted through
Mason County Code Title 14 Section 14.17 is attached. Submit documents should clearly identify
code compliance.
• ADDRESSING: Referencing IFC, Section 505 and Mason County Code Chapter 14.28, all new
buildings shall have an approved address.
• PERMITS REQUIRED FOR PROJECT:
o BUILDING (each structure)
o SIGN (each business)
ADDITIONAL NOTES: Current Code: 2015 IBC and 2015 IECC/VVSEC.
• CONSTRUCTION PLANS, drawn to scale. Include floor plan, elevations, cross section, cross section,
construction details, etc.
• MECHANICAL PLAN, (If a deferred submittal must be indicated on plans at submittal)
• NON-RESIDENTIAL ENERGY CODENENTILATION & INDOOR AIR QUALITY CODE INFORMATION.
• A PLAN REVIEW FEE WILL BE COLLECTED WHEN THE BUILDING PERMIT IS SUBMITTED.
VALUATIONS ARE BASED UPON THE MOST RECENT BUILDING STANDARDS VALUATION DATA.
DESIGN CRITERIA:
SEISMIC ZONE: D2
WIND SPEED: 85 MPH basic 110 ultimate, Exp. B (Unless proven otherwise)
GROUND SNOW LOAD: 25 PSF
REFERENCE CODE EDITIONS: Effective August 9, 2016
2015 INTERNATIONAL BUILDING CODE(IBC), INCLUDING APPENDIX CHAPTERS C, E AND H, EXCLUDING
H106; SECTIONS 101 THROUGH 107, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, AND EXCLUDING
APPENDIX CHAPTERS A, B, D, F, G, I, J AND K AND; ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-
50.
2015 INTERNATIONAL EXISTING BUILDING CODE(IEBC)
2015 UNIFORM PLUMBING CODE(UPC), PUBLISHED BY THE INTERNATIONAL ASSN. OF PLUMBING AND
MECHANICAL OFFICIALS (IAPMO)AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-56 AND WAC
51-57, EXCLUDING SECTIONS 102.4 AND CHAPTERS 12, 15, AND 16, PART I.
2015 INTERNATIONAL MECHANICAL CODE(IMC), PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, AND
THE 2009 INTERNATIONAL FUEL GAS CODE AS ADOPTED THROUGH THE WASHINGTON STATE BUILDING CODE WAC
51-52.
2015 INTERNATIONAL FIRE CODE (IFC) PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, EXCLUDING
APPENDIX A, D,AND K AND ADOPTING APPENDICES B,C,E,F, G AND ADOPTING THE WASHINGTON STATE BUILDING
CODE WAC 51-54.
2015 INTERNATIONAL ENERGY CONSERVATION CODE(IECC), AS AMENDED BY WASHINGTON STATE
BUILDING CODE WAC 51-1 1
To view the Mason County Building and Construction Code and adopted amendments go to the
Mason County website at: www.co.mason.wa.us