Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2022-00203 Remodel - BLD Application - 2/18/2022
MASON COUNTY COMMUNITY SERVICES Permit No: 1 PERMIT ASSISTANCE CENTER: = jj •BUILDING a PLANNING•PUBLIC HEALTH a FIRE MARSHAL 615 W.Alder Street,Shelton,WA 98504 Phone Shelton.(360)427-9670 ext.352•Fax:(360)427-7798 Phone F E B 18 2022 Belfair.(360)2754467•Phone Elms:(360)482-5269 BUILDING PERMIT APPLICATION er Street PROPERTY OWNER INFORMATION: I CONTRACTOR INFORMATION: NAME: BENJAMIN AND STAGY C70UX i NAME: INFINITY DE516N5 MAILING ADDRESS:22403 NE 10 5T MAILING ADDRESS: 11101 108TH AVE 5E#451 CITY: SAMMAMISH STATE: yAA._ZIP:98014 CITY: RENTON STATE:WA. ZIP:98055 PHONE#1: 495 41-7 4or;g PHONE: CELL: 605 280 8091 PHONE#2: EMAIL: inTinitudesiansllc icloud.com EMAIL: ben@pypartners.com L&I PEG# GG INFINDL840P6 EXP. 2/24/2023 PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER©DE516NER NAME KENT VIGARY EMAIL kentAgan.la(")�t ahoo.com MAILING ADDRESS 16225 5E 4ND PLACE CITY BELLEVUE STATE WA ZiP9800b 00. PHONE.425 4439361 CELL 425 443 9381 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 32232 50 03002 ZONING LEGAL DESCRIPTION(Abbreviated)HOOD CANAL LAND IMP C.O BLK 3 5T RT 1 Ob LOT2 ( ) FIRE DISTRICT b SITE ADDRESS 4981 E STATE ROUTE 106 CITY UNION,WA. J DIRECTIONS TO SITE ADDRESS 5MI,EAST OF HY-IY 1011106 JUNCTION ON 106 NORTH SIDE,(WATER)SIDE IN UNION. IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NOES SNOW LOAD:-ILpsf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check n11 rhai nppl)): SALTWATER® LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW❑ ADDITION❑ ALTERATION® REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence.Gmnge.Commercial Bldg,Bfc.) IS USE: PRIMARY❑ SEASONAL® NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2 112 HEATED STRUCTURE? YES OF/We Bldg)® YES(Parrfs)ofBldg)❑ NO❑ I DESCRIBE WORK 2ND FLOOR,ADD 1 LARGE DORMER WEST ROOF AND 2 SMALLER DORMERS EAST AND WE5T G /,f.F FINICfJ�TTIf.4Pa[,F.� r1l-INJF I,N,(F�f�1ST um�F•A'(IT�OWNT,iN SQUARE FOOTAGE:(proposed) EXISTING ROOF. K l��G`1 L n- 'RtMfJ(,VL- fh' I ST FLOOR sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. KrIt DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.it. OTHER sq.R GARAGE sq,ft. Attached E Detached❑ CARPORT sq.ft. Attached❑ Detached❑ I MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC® SEWER❑ / NEW❑ EXISTING❑ PLUMBING IN STRUCTURE? YES❑ NO❑ Ifyes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES❑ NO® EXISTING SQ.FT. EXISTING BEDROOMS 3 PROPOSED BEDROOMS TOTAL BEDROOMS 3 OWNER acknowledges that submission of inaccurate Information may result in a slop work order or permit revocation.Acknowledgement of such is by I signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,Including any easement holder or parties of interest regarding this project.The owner or legal representative,represents that the information provided Is accurate and grants employees of Mason County access to the above described property i and structures)for review and inspection.This permit/application becomes null&void if work or authorized construction Is not commenced'within 180 days or If construction work is suspended for a period of 180 days. - PROOF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT,A ICATION OF 180 DAYS OF MORE WILL CAUSE THE APPUCATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) 6 2 2--- f Signature of OWNER dlus stoned by the OWNER Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH MASON COUNTY COMMUNITY SERVICES Penn ttNo:�i C12022 -LLfe'p� PERMIT ASSISTANCE CENTER: BUILDING •PLANNING •FIRE MARSHAL • 615 W.Alder St-Shelton, WA 98584 www.co.mason.wa.us RECEIVED Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 • Phone Belfair. (360)275-4467• Phone E/ma:(360)482-5269 FEB 18 2022 PLUMBING & MECHANICAL PERMIT APPLICATION_ er Street OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: BENJAMIN AND STAGY GOUX NAME: T B D MAILING ADDRESS: 22403 NE 10 5T MAILING ADDRESS: CITY: 5AMMAM15H STATE: WA. ZIP: gb014 CITY: STATE: ZIP: U16PHONE: _425 41 1 4069 PHONE: CELL: CCEL NE: EMAIL : ben@pvpartners.com L&I REG# EXP. INFORMATION: rJRCEL NUMBER(12 Digit Number): 32232 50 03002 Zoning: AL DESCRIPTION(Abbreviated): HOOD CANAL LAND IMP CO BLK 3 5T RT 106 LOT2 =E ADDRESS: 4951 E 5TATE ROUTE 106 CITY: UNION, WA. CTIONS TO SITE ADDRESS: CQMI. EAST OF H 4Y 1011106 JUNCTION ON 106 NORTH SIDE, 0ATER)51DE IN UNION. TYPE OF JOB: NEW=ADD=ALT[:�C]REPAI OTHER=USE OF BUILDING 5 F R LOCATION OF FIXTURES/UNITS—IsT FLOOR 2xD FLOOR BASEMENT=GARAGE=OTHERO PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric=LPGC=JVatural GasEDDuctless= Toilets 3 Type of Unit No.of Units Fees Bathroom Sink 5 Furnace Bath Tubs l Heat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks 1 Wood/Gas/Pellet Stove Dishwasher 1 Kitchen Exhaust Hood 1 Hose bibs Dryer Vent Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X Signature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev: 1/27/2016 JBN c s NameAlts; Parcel#-3;�A;32 5b 012M2 BLD# 2022 - 66Z03 Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X = X = Measurements for buildings are taken at the X — perimeter of the farthest projections (example: eaves/gutters) X = Driveways X X = Length of drive begins at the right of way X — Parking Areas X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition X — above table Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read, acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor. 1 further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read, acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone: (360)427-9670 EXT.450 Mail:P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT.352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 EH APPROVE 02/24/2022 EH SETBACKS A)Drainfield/Reserve requires 10'setback from footing/foundations B)Septic tank(s)requires 5'setback from all footing/foundations G N L Q No foundation/perimeter drains within 30'down-gradient of drai field/ H O p D reserve area D)No cut(s),bank(s)(greater than 5'&over 45 degrees)within 50' N bl 4b,5F E 60.00' yvn-gradient of drainfeld/reserve area LOT 2 LOT 1 LOT 3 1025 5F NARRATIVE 1)UPPER FL: IT 15 PROPOSED TO BUILD A 51MILAR DORMER AS THE EXISTING EAST DORMER ON THE WEST 51DE OF THE UPPER FLOOR.THI5 AREA 15 CURRENTLY by 26'-4' 25'-10' HEATED 5PAGE AND WILL BE USED AS AN OFFICE. EXIS NG BRICK PATIO I 2)IT 15 PROPOSED TO FINISH THE EX15TINO ATTIC EXISTING DECK SPACE OVER THE GARAGE INGLUDING THE ADDITION OF 2 DORMERS ONE ON THE EAST SIDE AND ONE ON THE WEST SIDE.THESE WILL ADD LIGHT AND EGRESS TO THE SPACE. 2)MAIN LEVEL:IT 15 PROPOSED TO ENLARGE THE EXISTING KITCHEN BY REDUCING THE MAIN BATH TO A POWDER ROOM, ALL NEW KITCHEN CABINETS WILL BE INSTALLED. PROP05 NEW 326 5F SHED IT 15 AL50 PROP05EO TO REMODEL THE MASTER BATHROOM EXI5TIN HED DORMER WITH NEW SHOWER AND CABINETS. THE PROPOSED WORK DOES NOT EFFECT THE EXISTING PROPERTY THERE WILL BE I NO EXCAVATION OR EARTH DISTURBANCE ENTRY PORG NO CHANGE IN OCGUPANGY. PROJECT INFORMATION OWNER: b; 16 10, 4 W BEN AND 51ACY GOUX CV 'rt1'� A r PROJECT ADDRE55 5 N 4961 E STATE ROUTE 106 UNION,NA. IA P/N 522325003002 O O LEGAL: 111 Z HOOD CANAL LAND IMP GO BLK3 2NEWATT CDORMERS 5T RT 10b LOT 2 Ln L = LOT 51ZE: 1025 SF s ANTICIPATED DISTURBED AREA: 0 Z < EX15TING RE5IDENCE AGLA 2613 WITH FINISHED ATTIC PROPOSED NI5HED AT7IC \\ o ATTAGHED GARAGE 6505F AREA 4125F � \ PROP05ED EXISTING SPACE CONVERTED TO HEATED SPACE 412 5F I \ NEW AGLA RESIDENCE 2813 5F CONCRETE WALK LAN ER 11 EXI5TING BLACKTOP PARKING A'CEA \ / II 60.00, — W M v N STATE ROUTE 106 ° � °'°. a:"~°°TM°~ N O u> ry r.r4(scrnsl Q/ w°e1TieC1 5 — � �5._ISl3lLWle[➢c�eoirs SCALEV-20' VIGARY RE51DENTIAL DESIGN DATE: 2/3/22 REV. SGALE:1"=20' �o {- P�I►2. G 51TE PLAN -- - — -- �jIC1202Z -' 002-o NEW RESIDENCE FOR BENJAMIN AND STAGY GOUX 4981 E STATE ROUTE 106 DRWN.8Y: SHT# UNION,YVA K.VIGARY 1 /7 RECEIVED MASON COUNTY FEB 18 2022 = , COMMUNITY SERVICEfS W. Alder Street Building,Planning,Environmental Health,Community Health These requirements apply to all IRC building types, including detached one-and two-family dwellings and multiple single-family dwellings (townhouses). Contact Information Project Information Own; ame: Site Address:ea 6 !(>t0cow lap Mailing Address: It) 5 r Uh IUA_. W A 9 g59 a Parcel Address: 3a�. 3a-5o � 63002 Acry are Feet(total): (� ZZZZ— 06 W3 J Ventilations Compliance: 0 Whole House Ventilation system F� Whole House Ventilation using exhaust fans&window or wall Integrated with a Forced Air fresh air vents(M1507.3.4) System(M1507.3.5) Other,describe: Instructions:This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings:Table R402.1- Insulation and Fenestration Requirements by Component,Table R406.2- Fuel Normalization Credits and 406.3- Energy Credits. All Climate Zones(Table R402.1.1) R-Value a U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC bje n/a n/a Ceiling E 49 i 0.026 Wood Frame Wall g,h 21 int 0.056 Floor 30 0.029 Below Grade Wall`,h 10/15/21 int+TB 0.042 Slab d,f R-Value&Depth 10,2 ft n/a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. "10/15/21+5TB" means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d I R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. Prescriptive Path—Single Family 2018 Washington State Energy Code-R 3 2018 Washington State Energy Code—Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family—New&Additions effective February 1,2021 Version 1.1 These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings(townhouses). Project Information L Contact Information BEN AND STACY GOUX KENT VICARY 987 E.ST ROUTE 106 UNION,WA 116225 SE 42ND PL. BELLEVUE,WA Instructions:This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed.Based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. Authorized Representative Date P2J15/2022 All Climate Zones Mable R402.1.J1 __-- ---___-- R-Value' _ U-Factor' Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a _ 0.50 _ Glazed Fenestration SHGC b,e n/a n/a Ceiling e 49 0.026 Wood Frame Wall 9,1 21 int 0.056 Floor 30 0.029 Below Grade Wall Gh 10/15/21 int+TB 0.042 ' Slab d f R-Value&Depth 10,2 ft n/a R-values are minimums.U-factors and SHGC are maximums.When insulation is installed in a cavity that is less a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. "10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth i e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section RS03.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. g I For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for climate zone 5 of ICC 400. Int. (intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard �Jit raming 16 inches on center, 78%of the wall cavity insulated and headers insulated with a minimum of R-10 nsulation. Prescriptive Path—Single Family 2018 Washington State Energy Code-R 1 2018 Washington State Energy Code-Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family-New&Additions(effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit:3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit:6 credits All dwelling units that are not included in#1 or#3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table,review the details in Table 406.3(Single Family),on page 4. Summary of Table R406.2 and 406.3 heatin o T -- Heating O tions Fuel Normalization Descriptions tio Credits-select ONE ns g p tion User Notes p 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 GI 3 Electric resistance heat only-furnace or zonal -1.0 ❑ �4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy Credits-select ONE Options Energy Credit Option Descriptions energy option from each P category 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 Efficient Building Envelope 0.5 r!] 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 1 2.4 Air Leakage Control and Efficient Ventilation Li 2.0 ❑ 3.1a High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 ❑ 3.3a High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 ❑ 3.5 1 High Efficiency HVAC 1.5 ❑ 3.6a High Efficiency HVAC 2.0 ❑ 4.1 High Efficiency HVAC Distribution System 0.5 ❑ 4.2 High Efficiency HVAC Distribution System 1.0 ❑ Prescriptive Path-Single Family 2018 Washington State Energy Code-R 2 2018 Washington State Energy Code—Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family—New&Additions(effective February 1,2021) Summary of Table R406.2 Cont. Energy Credits-select ONE Energy Credit Option Descriptions(cont.) energy option from User Notes Options each category d 5.1d Efficient Water Heating 0.5 ❑ 1-5.2 1 Efficient Water Heating 0.5 ❑ 5.3 Efficient Water Heating_ 1 1.0 _❑ 1 5.4 J Efficient Water Heating 1 1.5 ❑ 5.5 _Efficient Water Heating _ _ ( 2.0 ❑ 5.6 1 Efficient Water Heating 2.5 ❑ 6.1e I Renewable Electric Energy(3 credits max) 1 1.0 Q 7.1 1 Appliance Package 1 0.5 ❑ Total Cmdhs I 1.5 Calculate Total clear Form a. An alternative heating source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4)or C403.3.2(5) c. Equipment listed in Table C403.3.2(1)or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category S.Option 5.1 may be combined with options 5.2 through 5.6.See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. For Building Officials Only Prescriptive Path—Single Family 2018 Washington State Energy Code-R 3 2018 Washington State Energy Code—Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family—New&Additions(effective February 1,2021) _ Table 406.3—Energy Credits(Single Family) Option I Credits:SF 1. EFFICIENT BUILDING ENVELOPE OPTIONS Only one option from Items 1.1 through 1.7 may be selected in this category. Compliance with the conductive UA targets is demonstrated using Section R402.1.4,Total UA alternative,where [1- (Proposed UA/Target UA)]>the required%UA reduction. j Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.1 i Vertical fenestration U=0.24 O.S. Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.2 1. {Vertical fenestration U=0.20 I Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U=0.28 j Floor R-38 1.3 Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and 0.5 under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U=0.25 Wall R-21 plus R-4 ci Floor R-38 1.4 Basement wall R-21 int plus R-5 ci 1.0 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and un der entire slab or Compliance based on Section R402.1.4:Reduce the Total conductive UA by 15% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U=0.22 Ceiling and single-rafter or joist-vaulted R-49 advanced Wood frame wall R-21 int plus R-12 ci Floor R-38 1.5 Basement wall R-21 int plus R-12 ci 2.0 !Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or I Compliance based on Section R402.1.4:Reduce the Total conductive UA b 30% p y Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U=0.18 Ceiling and single-rafter or joist-vaulted R-60 advanced Wood frame wall R-21 int plus R-16 ci 16 Floor R-48 3.0 Basement wall R-21 int plus R-16 ci Slab on grade R-20 perimeter and under entire slab Below grade slab R-20 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 40%. Advanced framing and raised heel trusses or rafters Vertical Glazing U-0.28 1.7 R-49 Advanced(U-0.020)as listed in Section A102.2.1, Ceilings below a vented attic and 0.5 R-49 vaulted ceilings with full height of uncompressed insulation extending over the wall top plate at the eaves. Prescriptive Path—Single Family 2018 Washington State Energy Code-R 4 Simple Heating System Size:Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA Manuals J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you.If you do not see the selection you need in the drop-down options,please contact the WSU Energy Program at energycode@energy.wsu.edu or(360)956-2042 for assistance. Project Information Contact Information BEN AND STACY GOUX I IKENTVICARY 4987 EAST ST ROUTE 106 116225 SE 42ND PLACE UNION,WA. I BELLEVUE WA. Heating System Type: o All Odw Systems 0 Heat Pump To see detailed instructions for each section,place your cursor on the word'Instructions" Design Temperature Instructions — Design Temperature Difference(AT) 47 $hellion A=Indoor(70 degrees)-outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 691 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 8.0 5,528 Glazing and Doors U-Factor X Area = UA Instructions +. ().0,28 . 0.280 74 20.72 11� Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA ,structions R-0 _ • 0.026 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA 0.020 691 13.82 R-49 Advanced • Above Grade Walls(see Fig"i) U-Factor X Area UA R-211NT plus R-12 d 0.032 F 378 12.03 It Floors U-Factor X Area UA NR-38 •— 0.025 F 474 11.85 Below Grade Walls(see Figure 1) U-Factor X Area UA nstructlons � ectR-value No selection --- Slab Below Grade(me Figure+) F-Factor X Length UA Instructions Select owAitioning No selection — Slab on Grade(see Figure 1) F-Factor X Length UA Instructions Select R-Value -.�.- r J • No selection -- �� Location of Ducts Instructions " -..... _ Duct Leakage Coefficient _Conditioned Spam 1.00 Sum of UA 58.42 Envelope Heat Load 2,746 Btu/Hour Figure 1. Sum of UA x AT Air Leakage Heat Load 2,806 Btu/Hour Volume x 0.6 x oT x 0.018 Above Grade Building Design Heat Load 5,552 Btu/Hour Air leakage+envelope heat loss Building and Duct Heat Load 5,552 Btu/Hour Ducts in unconditioned space:sum of buik/ino heat loss x 1.10 Ducts in conditioned space:sum of building heat loss x 1 Maximum Heat Equipment Output 7,773 Btu/Hour Buildina and duct heat loss x 1.40 for forced air fumace Building and duct heat loss x 1.25 for heat pump (071VV13)