HomeMy WebLinkAboutBLD2014-00463 Heat Pump - BLD Permit / Conditions - 5/27/2014 Inspection Line (360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. 3 426 W. Cedar P.O. Box 279
Shelton, WA 98584
MECHANICAL PERMIT BLD2014-00463
OWNER: EDWARD STOLESEN RECEIVED: 5/27/2014
CONTRACTOR: SUNSETAIR INC. 360.456.4956 LICENSE: SUNSEA"220CM EXP.- 2/3/2015 ISSUED: 5/27/2014
SITE ADDRESS: 110 E MASON AVE UNION EXPIRES: 11/27/2014
PARCEL NUMBER: 322325010302
LEGAL DESCRIPTION: UNION HOOD CANAL LAND & IMP CO BILK 103, LOTS 37 & 38
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
DUCTLESS HEAT PUMP
General Information Setback Information
Front: Ft. Shoreline: Ft.
Type of Use: SF Insp.Area:
Rear: Ft. Slope: Ft.
Type of Work: MEC Fire Dist.: $
Side 1: Ft.
Valuation:
Side 2: Ft.
Mechanical Fixtures FEES
Type Qty. Type By Date Amount Receipt
Heat Pump 1 Mechanical Permit Fee TW 5/27/2014 $18.20 S220140000C
Mechanical Base Fee TW 5/27/2014 $28.50 S220140000(
Final Inspection Fee TW 5/27/2014 $73.00 S220140000(
Total $119.70
BLD2014-00463 Please refer to the following pages for conditions of this permit. Page 1 of 3
CASE NOTES FOR
BLD2014-00463
CONDITIONS FOR
BLD2014-00463
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
x
2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X _,
3) To perform an inspection the Mason County Building Inspector will need to access the interior of the structure. An electrical permit completed and
approved by Washington State Labor& Industries must be available on-site during the inspection.
The Mason County Building Inspector will inspect the following:
Verify that the system is installed in accordance with manufacturer specifications;
The inspector will check to make sure that the exterior unit is permanently installed and supported,
the exterior unit complies with required setbacks to property lines,
fuel tanks are located at least 10-ft from the system, a source of ignition,
all exterior penetrations are properly sealed,
condensate lines are installed and are properly supported, including proper material, slope, and that the condensate line terminates to a proper location
outside of the foundation,
copper refrigerant lines are insulated with '/" thick continuous closed-cell foam insulation or better,
indoor units are located at least 3-ft from smoke and carbon monoxide alarms,
and that modifications made to the structure, to install the unit, does not affect existing structural members.
X '�4
4) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC
Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances),
repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created.
X �� K
BLD2014-00463 Please refer to the following pages for conditions of this permit. Page 2 of 3
5) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X ._�` \
6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinances and building regulations.
X .\ Y
7) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prevented action from being taken. No more than one extension may be granted.
X 11S
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
C:' � -7
nature Date
OWNER - REPRESENTATIVE - CONTRACTOR
Print Name (Circle one to indicate)
BLD2014-00463 Please refer to the following pages for conditions of this permit. Page 3 of 3
oCONCRETE Gas Piping MANUFACTURED HOME �1
o Interior-Date By 0
A Footings/Setbacks
Ribbons
Extetw-Date B m
y
Co ate By INSULATION Date Sy N
m
w Foundation Walls BG/SLAB INSULATION Set-up Z
Date By Date By Date By v
FRAMING Floors FIRE DEPARTMENT D
Date BY Date By
Dale By ----- 0
PLUMBING Date VftIs By DECKS
Da to By
Groundwork Vault TANKS
Date By Date By
Date By Attu
D.w.v
Date BY
OTHER
Date
By DRYWALL Type.
Date By
Waller Line Date By Type: W
-0 Date fay Int.Brace Wall Date By r
Cn MECHANICAL Date By INSPECTION N
cD Fire Seperaticn O
m �
m Da?c Date By Date 40-
O
Pass or ` Request Inspect. C1
Type of Insp. Fall Date Date Done By Comments w
o
0.
cc
Cn
v
O
a
o'
D
y
O
5
N
(D
3
N
(Q
(D
0
r �
MASON COUNTY PERMIT NO.
DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING•PLANNING.FIRE MARSHAL
WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352
{ Mason County Bldg. 111,426 West Cedar Street (360)275-4467 Belfair ext.352
PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352
PLUMBING & MECHANICAL PERMIT APPLICATION a31�3
OWNER INFORMAT ON: CONTRACTOR INFORMATION:
E NAME: NAME: Y1 Q,t' NI r UnU
! MAILIN ADDRESS: MAILING ADDRESS: 5a[ UL1 I a SE
I CITY: ATE:PI� ZIP: CITY:i�u STATE:j�(t ZIP:PHONE: �';�Mg
CELL: PHONE: - CELL:
EMAIL: EMAIL.
L&I REG#`U rl' ga-k gLX trq EXP.PARCEL
i
I INFORMATION:PARCEL NUMBER(12 DIGIT NUMBER):
LEGAL DESCRIPT QN(A B y.ATEEDn: j)n_ a �- (tn CD Gib 3_ 3
SITE ADDRESS: 1 tU1 �/�I,A oY+ t r� P CITY: r
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB
NEW ADD ALT REPAIR OTHER USE OF BUILDING
LOCATION OF FIXTURES/UNITS— Is'FLOOR 2r1DFLOOR BASEMENT GARAGE OTHER
i —
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of.Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump____
Toilets Type of Unit No.of Units Fees
Bathroom Sink Furnace
c I
Bath Tubs Heatpump 5>
E Showers Spot Vent Fan
I Water Heater Propane Tank
Clothes Washer Gas Outlets
I{itahen Sinks Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust Hood
Hosebibs Dryer Vent
Other Other
j! Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate Information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare
that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including
any easement holder or parties of interest regarding this project The owner or authorized agent represents that the information provided is
accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This
permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is
suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK 1S BY MEANS OF INSPECTION.INACTIVITY OF THIS
PER PLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
X_ q xf/V
Signatu e of Applica Date
X Owner/Owners Representative/Contractor
PrkJ Name (indicate which one)
llEP.A'RTM'F,N`I'AL kEVIEW WOVEb W IVI IX tix'N `FA S/I OI' l TIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL