HomeMy WebLinkAboutRetaining Wall - BLD Engineering / Geo-tech Reports - 9/19/1995 ► / ,OB ROgE RSS JOHN R. SLADEK, P.E. SHEET NO. OF Consulting & Design Engineer CALCULATED BY DATE OLYMPIA, WASHINGTON 98501 (206) 459-4254 CHECKED BY DATE rzrz SCALE ( 5UgIITTAI. FoR ENGINES. U) RETAINING WAI,, 114m,rqAN RE510ENCE, 0 `11/RAt ID C0ou Ne,PAR,ED FOR ; ZAELTOt4 , Jwwi ROK-IZT', / CONSfZUCT10N CONSUL-n v Ay50CIATES 0 WA, 5EE. MOTES � SPE.CIFICATIONS ITT-9 N- I FOv, l,i1 krt OP . ENGINEERED �ESIVN, 5Ugl(mT ' INrE% bUPQECr SuEFr �1= rJoTES SI�.cIFlcAnoNS �-4 ; DETAIL DETAIL g/ r L 5r2UCTU1ZAL CALCULATIONS 7 - G4 �ANUFaCTL) REIN' S CUT 5AEEVS R. S1 q y i. 212s6 O.JAL�' • � ��� �SEP 1 � 199� -;F�aFs 9 i� 95 1C/g: e: •:": •.:.,.3tRi 1J v'aW F�M TiKI iliti:s.Mn f+-0apl Holmes Residence Pyramid Court Mason County, WA. NOTES & SPECIFICATIONS FOR ENGINEERED RETAINING WALL 1) Engineering design is for the retaining wall and its foundation only. All other framing, including other building footings, any required holdowns or other anchors not detailed in these plans are not included. All temporary shoring, bracing, forms and other construction materials or methods are not included in the engineered design and shall be the sole responsibility of the Contractor. 2) Retaining wall design and details are in accordance with the applicable provisions of the 1991 Edition of the Uniform Building Code. Assumed design loads for portions of building supported by the retaining wall are: - Roof: dead load: 15 psf; snow load: 25 psf. - Second floor: dead load: 25 psf; live load: 40 psf. Distribution of building loads to retainin wall are based upon framing layout shown on Sheet No. 3 of Building Plans. See structural calculations for assumptions and details of analysis. Notify Engineer of any alterations to building layout. 3) Detail dimensions are provided solely to clarify the intent of the design. All dimensions shall be verified by the Contractor prior to ordering material and/or fabrication of any components. 4) Assumed allowable bearing pressure at the base of footings is per the requirements of UBC Table No. 29-6 for Material Class 3 includingincreases specified in Table Footnote 3. Footings 9 shall bear upon undisturbed natural ground or structural fill meeting the requirements of Note 5. 5) Backfill at retaining wall and toe of footing, any utility or plumbing trenches, and any fill supporting footings shall meet the following requirements: a) Material shall be clean, 4 minus, gravel or gravelly sand Unified Classification GW, SW or GP. No more than 7% by weight of the backfill material shall pass the No. 200 Sieve as determined by ASTM D-1140. Except as noted below, in-situ material may be utilized as backfill at retaining wall. b) Clean 5/8' crushed rock backfill shall be used at all drains and other locations specified in the details. c) Backfill supportin footings or slabs, and backfill at toe of retaining wall footing shall be placed in uniform �ifts not exceeding 6' thickness, conditioned to optimum No content and compacted by at least three passes of a vibratory plate compactor. d) Backfill behind retaining walls not supporting concrete slabs shall be placed in uniform lifts not exceeding 12' thickness, conditioned to optimum moisture content and compacted by at least three passes of a vibratory plate compactor. e) In lieu of the requirements specified in Item 'c', backfill supporting footings or slabs be placed under the supervision of a test laboratory approved by the Engineer. Backfill shall be compacted to minimum of 90% of maximum density as measured by ASTM D-1557. 6) Minimum 28 day compressive strength of footing concrete shall be 2500 psi. Concrete shall have a maximum water-cement ratio of .50. Maximum size of coarse aggregate at footings shall not exceed 2'. Bar reinforcement shall have a minimum yield strength of 60 KSI. Except as noted in details, typical rebar lap splice shall be 2'-6'. All lapped rebar shall be securely tied together. Reinforcement details and clear cover requirements not noted in the Plans shall be in accordance with UBC Section 2607. For increased water-tightness and durability, recommended minimum 28 day compressive strength of stem wall concrete shall be 3500 psi. Structural design of walls is based upon 28 day ComrrcS3i':e strength of 2500 psi. Wall concrete shall have a maximum water-cement ratio of .45, contain at least 560 pounds of cement per cubic yard and shall have an entrained air content of 4 to 6%. Water reducing admixtures compatible with tie air entraining admixture may be used to increase the concrete's workability. Maximum size of coarse aggregate at wall shall not exceed 1-112'. ' 3 Note 6, Concrete, continued. Wall control joints shall be located at all transitions in height and/or thickness, and at locations noted on Elevation, Sheet D-1. These joints shall be formed as noted in Standard Detail B/T. All concrete shall be thoroughly vibrated during placement using a 2' diameter spud vibrator. Footing concrete shall be wet cured for at least three days. Wall concrete shall be continuously wet cured for at least seven days. In addition to wet curing, it is recommended that two coats of Masterbuilder's MB 429 Curing Compound be applied to wall surfaces. Curing compound coverage per gallon shall be in accordance with the manufacturer's recommendations. Fresh and partially cured concrete shall be protected against the effects of cold weather and freezing. Contact Engineer for detailed recommendations as required. Backfill shall not be placed at walls until the wall and footing concrete have attained a minimum compressive strength of 2500 psi. 1) Two separate drainage systems are required to help maintain dry enclosed areas below grade: a) Perforated footing underdrains at foundations extending behind the full length of the retaining wall. Drains shall be 4' diameter perforated PVC pipe sloped a minimum of 112' per 10'-0' run to daylight. Drains shall exit to daylight at least 5'-0' down-slope of retaining wall foundations. Provide drain clean-outs as noted on Plan, Sheet D-1. b) All building down-spouts and other concentrated sources of run-off shall be connected to a separate 4' minimum diameter ADS non-perforated tubing tightline. This drain shall be sloped a minimum of 112' per 10'-0' run to daylight, and shall exit at least 5'-0' down-slope of building foundations. Provide clean-outs at up-slope ends and at any sharp bends. Notify Engineer of any springs or other sources of run-off encountered during construction and/or final grading so that drainage system may be modified as required. All perforated drains shall have openings oriented toward the base and shall be bedded in a 3' minimum thickness of crushed rock fill. See Note 5 and Details for fill material requirements, dimensions and protection at perforated drains. All drain line components shall be connected with the appropriate 'Ell', 'Tee' or 'Y' fittings. Clean-outs shall be fitted with end caps. 8) Depending upon specific site conditions, uses and finishes anticipated for below grade space, quality of construction and compliance with Plan Details and Notes L Specifications; separate waterproofing measures at the retaining wall may be required. To provide the maximum level of moisture protection for below grade finished areas, the Engineer generally recommends the following measures: a Snap-ties used at stem wall have a neoprene waterproofing washer at mid-length. b Installation of waterstops at wall/slab construction joints as shown in Detail A/T. c Installation of a positive waterproofing system, such as American Colloid Company's Volclay Type 1C Panels. If such systems are to be considered, contact Engineer for additional details prior to construction. Based upon Engineer's site visit and his understanding that below grade areas of building will be utilized only as an unfinished garage, special snap-ties, waterstops and Volclay Panels are not required. This conclusions would change if the Owner anticipates a future conversion of garage to finished space. ' 4 ZI The following Notes 9 and 10 are recommended specifications for cast in place and drilled-in adhesive anchor bolts. No engineered design has been completed for anchor bolts on this project. Notes 9 and 10 exceed the minimum prescriptive requirements specified in Chapters 25 and 29 of the Uniform Building Code. 9) Anchor bolts at wood frame walls shall be conventional cast in place 'J' bolts or drilled-in adhesive anchors meeting the requirements of Note 9. Unless otherwise noted, anchor bolts at wood frame walls shall be 5/8' diameter, embedded a minimum of 7' into concrete and spaced as noted in the details. Where spacing is not specified, anchor bolts shall be spaced no more than 4'-0' O.C. and a maximum of 6' from each end of each sill plate. All anchor bolts at wood frame walls shall be installed with appropriate sized washers. Bolts shall be installed plumb and shall project above the top of concrete and shall extend completely through the uppermost sill plate as required to allow the installation of any washers or other hardware and provide full engagement of the nut without counterboring the sill plate. Simpson MA-6 Mudsill Anchors may be substituted for anchor bolts. Locate and space mudsill anchors as noted above. Fasten each mudsill anchor to sill plate with (6) N-8 nails. 10) Drilled-in anchor bolts and rebar dowels shall be Ramset/Redhead Epcon Epoxy Anchors. Except as noted in details, anchors/dowels shall be embedded into concrete as follows: - 3/8' diameter or No. 3 rebar: 4-1/2' minimum embedment. - 1/2' diameter or No. 4 rebar: 6' minimum embedment. - 5/8' diameter or No. 5 rebar: 7-1/2' minimum embedment. - 3/4' diameter or No. 6 rebar: 9' minimum embedment. - 1' diameter or No. 8 rebar: 12' minimum embedment. All anchor/dowels materials and installation shall be in accordance with the manufacturer's recommendations. Anchors substituted for cast-in-place anchor bolts shall project above the concrete as specified in the following requirements or as shown in the details. Unless otherwise noted, drilled-in anchor bolts at wood frame walls shall be 5/8' diameter ASTM A-307 steel threaded rod cut to the required length and spaced as noted in the details. Where spacing is not specified bolts shall be spaced no more than 4'-0' O.C. and a maximum of 6'from each end of each sill plate. All anchor bolts at wood frame walls shall be installed with appropriate sized washers. Bolts shall be installed plumb in holes drilled to the diameter required on the manufacturer's cut sheet. Bolts shall project above the top of concrete and shall extend corletely through the uppermost sill plate as required to allow the installation of any washers or other hardware and provide full engagement of the nut without counterboring the sill plate. Drilled-in anchor bolts shall be torque tested per the requirements of UBC Standard No. 24-8. Required torque capacities for drilled-in anchor bolts larger than 3/4' diameter shall be specified by the Engineer. To avoid crushing sill plates during testing, temporary installation of a 4' x 4' z 1/4' steel bearing plate may be required. Upon satisfactory completion of the test, the bearing plate may be removed and the permanent nut/washer installed snug-tight. JOHN R. SLADEK, P.E. Job: TyPICAL DETAIL. CONSULTING & DESIGN ENGINEER .OLYMPIA, WA 98501 Date: f_ Cu _ 19M9 By: 3RS Page 5 of �(206) 459-4254 APRIL Rouc,1AENE.D CONSTRUCTION ,OINT ExTEQOR FACE CANTINu0s WATT R5TO' , VOLCLAX RX , SEE, ATTACUED COT ✓ SNEErs, 2n OPTIONAL. LocATION WATI^9,5mp REBAR BELOW GRADE SLAB FOOTING LOCATE QATE95TOP P RE FOR mONOLITNIC. FOOTING - 51AS POURS. bErAIL_ REF Tyr)\cAL SECT;oN NOTE 8 TYPICAL, DETAIL, WATER5TOP 14/0r TO SCALE.. JOHN R. SLADEK, P.E. Job: T�JPI e AL DETAIL CONSULTING & DESIGN ENGINEER OLYMPIA, WA 98501 Date: BY: ,1 R 5 Page of ',(208) 459-4254 CA01,K JOINT SIKAFL F-y - I o, 15�,L A.NT: WAIT Q5 LONG AS F Po551�LE To Ami CAULK, (IZEFE.RAF,L� AFTER CRAC uAs orz�cD L()j-"r).RE0NFI�1sN D �l D 'T 11 � �L��I vr POZ17ONTAL V,EBAR CONTI KOOUS L1CR055 �OINT a s 1 d FOIZ CONTR01. �01NT Ar EACW FACT OVER FULL NE16WT' OF WALL. "I CWAIFEfL ' TR I P5 RiPPEp R O I X Lu gU, STOC KI, PP;- FORDED Pv0DUCT5 5uC4 AS WIL.LIA 5 illiz- 6 �01 - FOR ER lay 8E S0657ITUTED, WALi, TNIcKNE55 JOINT DEPTW 0. a� OR LE55 i N 10 I�z Q DUA I L. eT TT PICAL DETAI L. WALL CONTIZOL �IOKV. t�Or To SCALE SEe PLAN FOR LDCATION t SPAC1Nv. JOB �QfiF_(ZT't JOHN R. SLADEK, P.E. SHEET NO. OF Consulting & Design Engineer CALCULATED BY �QS DATE F q OLYMPIA, WASHINGTON 98501 (206) 459-4254 CHECKED BY DATE SCALE A�.I.OvJAgI,F gEARl1JC� pRESSU¢E GV,AvFL, / 5AND t�XfOVE C WAWs U5F U 9 C TAF5LE- a- T� - 5 ArV--eIAL Typp- wimi roonNV BASF OP FOonNV 5'-0 F�Eow Ev mNV Ngrum, GRADE Au,pw 3 't3 USF �•° L 000 �y� crn+ u, .wuN.,•A's::eu:;Tp uiJc Rfv:K TQ;:Ii;ct.A.UY.6isi JOB SHEET NO. ryry( U OF CALCULATED BY J PA / DATE AN CHECKED BY DATE SCALE DESIGN laaos EARTH IZESSURE IN — S►TU `�c)It,S ARE 5AN0— GRAVE 1, I.EVr L Bac KFI L1., V- D '1 °z Fi�uRE Ito PER NA PAC , P VEI. D P R A l L 5a T pE 2 SOIL GRA / SaNI� RESTRICTS E E 7 y y �1 K N : 38 Phi hi Kv = 0 Au-ow Fork 100 Pit 5URCNARCvE C - `r/ u a�Qx ' 8,'1' PN �'S �38x8.�" �Z + . 50 1455 �ta3 ITES pl9 lor 2 14" (8, ".4 5BIA • A L3u1l omG LOADS 110 L.L, a•° (AD �,�� 320 kAip- WAw, M 60 z RooF Dl- A.° (i� rti� 66 5L 4•° (2" �, 100 688 �4 166 �4� DL joB ROSF-VkrS JOHN R. SLADEK, P.E. SHEET NO. 9 OF Consulting & Design Engineer CALCULATED BY .IRS DATE �F 4 OLYMPIA, WASHINGTON 98501 (206) 459-4254 CHECKED BY DATE SCALE C0t45TR.UCTI0N C0N171TlON RETg1NIN(, WALL I BAI;KFILL ONI.y i o � 3� — 5 • l�� �• 15� �� 83l 9� 4� 5q'1 � Ib TEI�1 P a P � k 1`1 5 FooTl>, . 5. �• 155 Pc� 801 . 63 61. t Aa4 d, 11, 2383. 611�• bill, S / 2d3 o 86 t aX 1'1 Q.• C 'Ay PJ 1 S F'S') o.r, _ AW, 8 1, 92 OKAY buolwa ougmc. C0N5TRUCT1014 z I. 2 PN - C W ram► + PAIhIVE PN _ 1A55 W = 2213 (FPA%ive I. (, I455 � - 2.213 (, , 60) 418 p9; REQ O .5 Kp (12,5 ��� )(1. �2 2 AtS OKAy .t...,.,mI1 Ne:0:� ncJw+�,.uass ul7i�t.,0uxr vnuLel�,�ltlilE hdW:.`�;. JOB ROFS�R'('S i JOHN R. SLADEK, P.E. SHEET NO. 10 OF Consulting & Design Engineer CALCULATED BY IR�7 DATE OLYMPIA, WASHINGTON 98501 (206) 459-4254 CHECKED BY DATE SCALE F-0AA1. COV401TIOR N INC.L.UDF [JLALJDIN(j 1% � 100 �s� 50RCNAq*a �'�13 ➢ Bill, " 4 -1 BuiLoiNG Dt_ '�to8 A.44 1151-1 O 5URCNARGa 150 �15 Oo "t 50 4.0 7qV. G49Ai;F- 5LAI3 4.°° PSG 300 2•00 00 •0 P 7Z31 p9� to 157 . -u►��� or 4 1 I 1015 — 5 toa 2a31 I. I°a . 91 ' :, RFSUt.TAt4r Ouf51DE of KERN • 2 (1511� _ I I2,3 fax 5 I l08 p' :C OKAY/) I d (F.S. or to I�� , _ t. :, OKAY 5�g4.4 1 5►.iDIN re GoNstOE� Sig, �uii.DWt; RF�'fi;A1N r 5LA13 DL 7A.% (36.'*X 50 psi) IL r-00w Anot4 41^ ?� ) 719000 pa + ?�•'Roof- D1. ?A.°( � (41.°XI2"n FwoR/ �5 317,3-4 REMININ6 WALL, 51.0 (1&51 09 + 110•0 (1115 p9�) I_ 7316314 USF F. 5. = 1.15 60 1,5 ( f P _ ( 1 w ) t o + F pa�ivE t PN = 4a ° 11Ia p9T ) = 824LA Ib 1391099 1'�3L9L 1 F PA4hlve /R��r !• 5� � ��3�1 tt°od3 b I Flor R o � I�►ivE . JOB ROgERr`� JOHN R. SLADEK, P.E. SHEET NO. L OF Consulting & Design Engineer CALCULATED BY IR5 DATE OLYMPIA, WASHINGTON 98501 (206) 459-4254 CHECKED BY DATE SCALE FINAL, CONDIT-tON BUIt-()jNG IX LL 7 51- 100 SuVCµARGE RutL.otty� L1., 5L 6' c) + 100 Q`�0 4 AA 18L4 , S CwAgAG-:� SLAB U, A.o' (AO P5�� 160 310,° 54 11 04 5411 6 X \ 5 I or F, S, ) bt.vRG OKay �y lNSPEcrtoN JOB 7,0REV-V7 - JOHN R. SLADEK, P.E. SHEET NO. 1� OF Consulting & Design Engineer CALCULATED BY .I Q DATE R�ET OLYMPIA, WASHINGTON 98501 (206) 459-4254 CHECKED BY DATE SCALE I + 3o C� 95 '01 = 5 'T5 Qy�y z .61 (wwo) 15600 P4 0 caa - . 10 151a00x �, �K - ,13/Z ,/ (�, - 151� 5 +� ' l�►/p ;, OKay 5NEAQ OKAY ey tw.'pecnow Curol<F or- VevmcaL. REgAR, e WAI-L # 5 Q ?A " AS y 1�00 F� . 10 ( ncox�' " - .11A )�17, BS (L) /L + 50 (L�/Z l S LONVITuwRAL V a6gg 0 WALL b� 8 0LO) Y JOB ROgE�.YYi JOHN R. SLADEK, P.E. SHEET NO. 13 OF Consulting & Design Engineer CALCULATED BY .IRS DATE m rM4 OLYMPIA, WASHINGTON 98501 (206) 459-4254 CHECKED BY DATE SCALE FOOTINV Dr StC�N 4�-0' ?30 30'1 230 !, 23� 5,04 TEN bl ON l � �OTl�t11 Cm 1 Ax 5 (2�? -230X4•0)' + 891 (A 0)'/3 44 M 8 mIZ10 16600 qi/Z I V �E SNt.AR OKAY 6y 1N5PFCT10N .-5W I iv l,h;i N NONi TOIL rRph 16'l;ar.,i xi 1 JOB RQF5 JOHN R. SLADEK, P.E. SHEET NO. 14 OF Consulting & Design Engineer CALCULATED BY �tiZZ�] DATE OLYMPIA, WASHINGTON 98501 (206) 459-4254 CHECKED BY DATE SCALE 1ZE13AQ tvE�oamEN r LEN NTH 5 VF-v-maL C FooriNL, 10� NOoK I`�" 0•C . SAS) QF-Q I r) 1AA; b'1 A '1513 . C s SUPPUED '0)( Izoo 13 E gE0 vir IN FdonNV Q Qt1 OxAy I � � 5 VF.RncAl, C WAt l- ° n s 3 0 5 ' y S�t;Er t5 • . o d , V D. D D p. �;Y:�y:•..; -.• ...+;+.•tip;'+r%' J. P 3 ' "•ih. a+v*T'r 4 ,., 7 .:. i. Al�uf: iha _ P permMentlil 32 � ?a'3't�r`�� �.����y��i .�'•1�„y�d�� "�i T�r'�K• w �.�."� wS�'iSi"_. t- �::•- • � 41`!r�`.s'.fy�.3c`-- ' b.1�. r f Qn mte points. � § 'xa°v :j-Y• Y 1`et.i •ti; 3S"Fk' Yh �r.G;.lx '�a'4p4 y�L• Z T�W.'✓,£r.:ll' �,�`�p'p^�r'�nr�"�°�� � r<<-...'�' � �'a ��- � �iF�.;ReaFC.,:. OW W+f"c II n.�...,4�• .fin M�.i - I V American Colloid Company WaterstepwRXehelps save time, MURVY... and concrete Installing conventional waterstops in con- crete joints is an important(but normally time- FOOTING JOINT consuming)part of concrete construction.It can also be very labor-intensive,reducing VERTICAL the profitability of the job.Most important, WALL JOINT conventional waterstops offer only a partial d solution to water infiltration,leaving architects, engineers,and contractors open to liability :e problems. Volclay®Waterstop-RX"'solves water infiltration a °, problems.It's easy to apply even by a single, - inexperienced laborer,cutting installation time in half.It eliminates split-forming and ., Waterstop-RX splicing.And,its self-healing properties Concrete assure that concrete joints remain protected o d permanently. How Waterstop-RX works The key to Waterstop-RX is its western sodium bentonite base.Specified for more D than 20 years for foundation waterproofing, bentonite swells in contact with water,forming . an impenetrable gel.This property also allows bentonite products to fill in small . cracks in concrete. Minimum 2" to Waterstop-RX comes in a coil.It is applied exterior wall surface. . by adhering the material to the butt end of �d • o • the concrete with RX Adhesive or concrete o cut nails—an operation that requires a single laborer.Then pour or place the next section a of concrete to complete the joint.No split i forming,splicing,or bonding is required as �■/ with conventional waterstops. Upon hydration,Waterstop-RX swells to Place Waterstop-RX inside form a self-healing compression seal that c . of outer most dowels. completely locks out water.This action also p prevents water migration along the waterstop and in keyways as an extra protection against 6• Q . penetration. All-temperature application Waterstop-RX has been engineered for use under virtually all temperature conditions. Unlike other popular joint sealants,Waterstop- RX does not become stiff and brittle in cold weather nor spongy and difficult to work with Waterproofing a .4 in hot weather.As a result,Waterstop-RX does not have to be heated in cold weather, G saving time and money.It also remains totally 4 flexible without shrinking,hardening,or oxidizing. Safe to use a Because Waterstop-RX is non-toxic,no a Waterstop-RX special handling equipment is required.It is clean to the touch,and does not contain any a material which can discolor or irritate the skin,helping eliminate lost man-hours. c ° a a• Note:Waterstop-RX is not an expansion a o ° c joint material and should not be used as such.Expansion joints are the responsibility °. a. c a ••a• i%D'o�: of OTHERS. a - '.a �"a \ Waterproofing Drain tile \ J Drain aggregate \•/ Placement of Waterstop-RX where slab rests on top of footing. Installation procedures 03250/AME Surface preparation BuyLine 3563 Joint surfaces should be clean and dry.For Typical sections showing placement of Waterstop-RX best results,Waterstop-RX Adhesive should be applied to the joint surface prior to adhering Waterstop-RX,especially on vertical joints. Waterstop-RX 101 The adhesive creates a tacky surface which allows for excellent adheFion to the concrete. ° v Q'. Positioning o Waterstop-RX is adhered to the butt end n . °• ° 4. .4 0 . of the previous concrete pour and should a 4 be positioned a minimum of 2"from the 4 • a exterior joint surface.Concrete cut nails, Waterstop-RX Adhesive,or both must be 4, ° . used to secure Waterstop-RX in place to .4 a prevent displacement of the material during the pour. Waterstop-RX may also be installed in a cast in place recess at the exterior side of the joint.In this situation,precautions must be taken to protect Waterstop-RX from hydration prior to backfilling and backfill 4 .• .-.. : must be compacted to 85%modified proctor C : c a: a °.4 minimum,adjacent to the joint.The o 4 - recess at the exterior of the joint should 4=. -a o a match the dimension of Waterstop-RX. �.' 4 a ° The ends of individual Waterstop-RX �� ��/��� ���� ������ i �� ��� G .' 4 coils should be butted together—never . minimum of 2" overlapped. (substrate) .'a " •'a to exterior b '.:e'. wall surface Applications Waterstop-RX is ideal for use on many types of poured in place and below grade a::Q,a precast concrete applications.There should ° be a minimum of 2"of concrete cover sep- ..:a arating the exterior face of the Waterstop- 4 Q• ' RX from the exterior side of the joint. NOTE:In cases of lightweight concrete or insufficient coverage,consult the manufacturer. Use On: Waterstop-RX 102 minimum 2" Precast concrete wall panel systems concrete coverage a' a Septic tanks and sewage treatment plants required. Q. Sanitary and storm sewer manholes Pipe(round,oval,flatbase,elliptical,and f^ 2" 2" a. arch types) a min. min. Cold joints in foundation slabs or walls ;� ° .' below grade Burial vaults Utilityvaults s•: a' . a_•a a: a.•a' Wet wells Box culverts Waste water treatment plants Portable water tanks 2" min. FIX Waterstop is available in two sizes as shown within the technical information on . the next page.The smaller size(FIX 102)is '�' ' ° ' Q v 4' .° typically used in smaller joints. v -a D. V -P A No matter which size RX Waterstop is used, both require a minimum concrete coverage a 4 of 2"from the exterior wall surface. a 4 G Note:Waterstop-RX is not an expansion n. ° 2" joint material and should not be used as n a 2" min. 4 such.Expansion joints are the responsibility min. Q a • a"• of OTHERS. ° 4 . 4' 4 .4 i a . 4 , r Volclay Waterstop-RX`is a flexible strip of bentonite waterproofing compound,coiled in Limitations i. ) two sizes.Dimensions and other specifications are as follows: In conditions where severe ground water �J RX 101 FIX 102 contamination is expected,please consult the manufacturer for compatibility infor- Dimensions 1" x 3/4" x 16'6" 3/a" x %" x 25'0" mation.Waterstop-RX should be confined Weight 50 lbs./ft.minimum 1651bs./ft.minimum within a concrete joint with a minimum 2" concrete cover to the exterior of the joint Carton Contents 100 L/F 150 L/F surface.Waterstop-FIX may also be installed) in a cast-in-place recess at the exterior Carton Weight 50 lbs. 25 lbs. side of the joint.In this situation,precau- Carton Size 10" x 14" x 10" 8" x 14" x 10" tions must be taken to protect Waterstop- FIX from hydration prior to backfilling and Pallet Size 4' x 4' 4' x 4' backf ill must be compacted to 85%of modified proctor minimum adjacent to Chemical Composition the joint.The cast in place recess should match the dimension of the Waterstop-FIX Material Test Method Waterstop-RX Results being used. Butyt Rubber- An exposed length of coil should not be Hydrocarbon submerged for extended periods of time. (%by weight) ASTM D-297 24.9% If Waterstop-RX exhibits considerable Bentonite SS-S-210-A 75.0% swelling prior to confinement in the joint, it must be replaced with new material.To Volatile matter AS D 6 Below 1% avoid displacement of Waterstop-RX during or prior to concrete placement,cut nails NOTE:Contains no asbestos fibers or asphaltics. and/or Waterstop-RX Adhesive must be Physical Properties used to hold the material in place.Proper y p care should be taken during concrete place- Property Test Method Waterstop-RX Results ment to avoid displacing the Waterstop-RX strip.Waterstop-RX is not an expansion Specific gravity joint product and should not be used at 77OF ASTM D-71 1.57 as such. Softening point ASTM D-30 N/A NOTE:In cases of lightweight concrete or insufficient coverage,consult the Penetration ASTM D-217 manufacturer. 150 GTL 58 300 GTL 85 Warranty Flash point ASTM D93-97 365 American Colloid Company warrants its mate- rials to be of good quality and will replace pressure test 231 ft.(100 psi) material proved to be defective.In no instance will American Colloid Company be liable for Accelerated aging (Mechanical oven Maintained 99% labor costs or incidental damage associated 4 hrs.@ 2120 F) solids with the use of this product,unless stated Flow resistance (3/4"overhead in a warranty for a specific project. joint exposed to Document 1350 F for 7 days) No flow This brochure contains information to sup- Storage life Indefinite plement information service available from Adhesion to clean, American Colloid Company's Building Mate- dry concrete Excellent rials Division and from local distributors. Application temperature Application Assistance range 50 to 1250F Local distributors of Waterstop-RX are quali- Service temperature fied to aid in solving problems related to use range -400 to 212OF of this product.In the event that your needs are special or you have an unusual situation, Notice:The information presented here is believed to be correct.However,since it is pro- your local Waterstop-RX distributor will vided without charge and without specific knowledge of the intended use or application of its arrange to have a factory representative product,American Colloid Company assumes no obligation or liability with respect to such contact you for personal assistance. use or application,and makes no warranty,either expressed or implied,as to the application or use of such product,or to the use or infringement of any patent or other proprietary rights Protected under patent nos.4534925 and 45349266. of American Colloid Company or others with respect to such application or use. Seal concrete joints quickly and permanently with the waterstop that heals itself—Waterstop- RX.For more information,contact your American Colloid Company distributor, or contact us direct. Distributed by: WARRANTY Theinfofmahon and data contained herein are believed to be accurate and reliable.Specaicabonsand other information Z�QLi, contained herein superssede ell previously printed material and are subject to change without notice. Manufacturer warranty of installed system is available.Contact seller for terms and sample document including all limitations. All goods sold by seller are warranted to be free from defects in material and workmanship. The loregoingwarrarnyis in lieu of and exclude all other warranties not expressly set forth herein,whether 0Kpress or implied American Colloid Company by operation ot law or otherwise including but not limited to any implied warranties of merchantability or fitness. p y Seller shall nob%liable for inCtoentalorconsequential losses,damages or expenses,directly or indirectly arising from Building Materials Division the sale.handling or used the goods,or from any other cause relating thereto,and seller's liability hereunderin any case Sf Is enpressly kmaed to the replacement(m the form originally Shipped)of goods:Kt mply, with t his agreement or at seller's 1500 W.Shure Drive \\� eledion,to the repot ent of,or creditin buyer with,an amount equal)to the purchase puce of such goods,whether such cl-sarelorbreac of warranty orreg$gene. Arlington Heights,IL 60004 My claim by buyer with reference to the goods sold hereunder for any cause shall be deemed waived by buyer unless sub matey to seller m writing w,thin thirty(30)days from the dale buyer discovered or should have disco-red,any claimed breach. 1-708-392-4600 Materials should be respected and tested by purchaser pro,to their use if product quality is subject to verification after FAX 708-506-6199 and 6195 shipment.Pertormance guarantees are normally supplied by the applicator. NOTE:Expansion joints shall be the responsibility of OTHERS. TELEX ITT 4330321 Form No.WS-200 293 5M Printed in U.S.A.