Loading...
HomeMy WebLinkAboutMIS99-0784 Dry Chemical - MIS Permit / Conditions - 12/30/1999 MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 M I S C E L L A N E O U S P E I T FOR INSPECTIONS CALL 427-9670 MIS99-0784 PARCEL :42O1724OOrTr PLAT : DIV : BLK : LOT : JOB ADDRESS : 6651 W SHELTON MATLOCK RD SHELTON APPLICANT : KIRK PETERSEN 426-3082 OVVNER : KIRK PETERSEN 426-3082 LEGAL : TR 1 OF SE NN ` PROJECT DESCRIPTION : DRY CHEMICAL SUPPRESSION SYSTEM FOR SPRAY BOOTH PROJECT LOCATION : SIX MILES DOWN SHELTON MATLOCK RD FROM HWY 101 OVERPASS . BUILD SITE AND EXISTING SHOP ON LEFT . PROJECT NOTES : TYPE AMOUNT BY DATE RECEIPT WETC $ 100 .00 KS 12/30/99 2056 TOTAL : 100 .00 OWN R OR AGENT DATE MIS_PRMT, rev: 04i01/92 COMPLIANCE TO ATTACHED CONDITIONS IS RE©U I RED Y MASON COUNTY Mason County Bldg. III 426 W. Cedar y P.O. Box 186 Shelton, Washington 98584 PERM I T C O NI] I T I O N S Case No . : MIS99-0784 For : KIRK PETERSEN Page : 1 1 ) 1 . TRIP TEST REQUIRED . 2 . P OVIDE NON A-RATED 4013C DRY CHEMICAL FIRE EXTINGUISHER LOCATED NEAR THE MANUAL PULL . X I 1 -7 MASON d COUNTY FIRE AL . CO U N �A& D Mason County Bldg. III 426 W.Ced �.. P.O.Box 186 Shelton,Washington 9 ,5�1L E EC'TF (360)427-9670 Copy N� CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIG N PUBLIC EDUCATION PERMIT NO. MASON COUNTY FIRE PROTECTION SYSTEM "S99-O�$�f PERMIT APPLICATION PLEASE NOTE:This application must be completed and accompanied by a minimum of three (3) copies of plans,specifications, and applicable calculations per Mason County Fire Protection Standards,and submitted to the office of the Mason County Fire Marshal. This is not a permit and failure to submit all necessary information will cause a delay and/or rejection of your submittal. When a permit has been issued,you will be notified. PLEASE PRINT OWNER: <I.aK ter,, Mg'rj _ PHONE:g2Co -3USZ FIRE DISTRICT SITE ADDRESS:(C&S-/ Shiu-"nj MASLUX MITY Sr4U,ra J STATE V#- ZI 90�- MAILING ADDRESS: A3 S[?V� CITY STATE ZIP LIEN/TITLE HOLDER: K N R-tc- ?*E.rKRd" ADDRESS: S'Am4- As Af3o✓iL- CITY STATE ZIP CONTRACTOR I1: tj icr-a1T ADDRESS: ("4/3(0 ehL4&tAj QvAD S1�_CITY OLY� ./ STATE *IP So CONTRACTOR PHONE# ZI(02 CONTRACTOR REG# &n i U-t-J F d`/yLIC PARCEL# "+ I�LEGAL DESCRIPTION: 7tZA -1- l+z or su, OLj- tt- i71 c F AoArrrmc of -r-uE Nvy LwAA (1- Or- BLDG. SQ. FT. (EXISTING/PROPOSED)lST FLN / 2ND / 3RD / USE OF BUILDINGrtrill�dW&-I �e4�Nr SCR 4� DESCRIPTION OF WORK: SPRINKLER: WET DRY STANDPIPE: WET DRY AUTOMATIC FIRE ALARM HOOD & DUCT DRY CHEMICAL_X�— WET CHEMICAL HALON NEW SYSTEM MODIFICATION RIEU QUt41P MONITORING STN PHONE r YOUR SUBMITTAL MUST INCLUDE: 1. DIMENSIONS, SCALE, NORTH ARROW 2. FLOOR PLAN AND CROSS SECTIONAL ELEVATION 3. ALL CONCEALED SPACES (LABELED COMBUSTIBLE AND NON-COMBUSTIBLE) 4. CUT SHEETS OR REFERENCES FOR ALL NEW DEVICES 5. LOCATION/DESCRIPTION OF ANY EXISTING DEVICES 6. BATTERY CALCULATIONS FOR FIRE ALARM SYSTEMS 7. RISER/WIRING DIAGRAM FOR FIRE ALARM SYSTEMS 8. HYDRAULIC CALCULATIONS FOR SPRINKLER SYSTEMS PLEASE NOTE: WORK MAY PROCEED ONLY IN ACCORDANCE WITH A VALID FIRE PROTECTION SYSTEM PERMIT ISSUED BY THE MASON COUNTY FIRE MARSHAL. A VALID PERMIT AND AN APPROVED SET OF PLANS MUST BE ON THE JOB SITE DURING CONSTRUCTION AND MUST REMAIN THERE UNTIL A FINAL INSPECTION IS DONE BY THE MASON COUNTY FIRE MARSHAL. FAILURE TO OBTAIN A VALID PERMIT PRIOR TO WORKING ON A FIRE PROTECTION SYSTEM AND/OR FAILURE TO PROVIDE THESE PLANS AND PERMIT FOR THE MASON COUNTY FIRE MARSHAL MAY RESULT IN A CITATION AND FINE. OWNER'S AFFIDAVIT I certify that I am exempt from the requirerrle of the Contractor's Registration Law RCW 18.27, and am aware of the Mason County ordinance requiremen for which this permit is issued and that all work will be done in conformance therewith. No changes will te- Firejithout first obtaining approval from the Mason County Marshal. OWNER: I , —' ' A DATE: CONTRACTOR'S AFFIDAVIT I certify that I am a currently registered contractor in the State of Washington and I am aware of the ordinance requirements regulating the work for which the permit is issued and all work done will be in conformance therewith. No changes will be made without first obtaining approval from the Mason County Fire Marshal. BY: DATE: 1 E452-LC9 ?Cbgat 9 e ISY-006 auuHd :. BEti-L64 XdA LLt - t7 90,42 ')N uaa.ano ePdd �� $ ' m N - 0 Go T - I TIV Zl d.. ULLS�Q�L _ _ m _ H1QIr1 ��S�II .Yt r N a W ti e _ x � a `0 � a _ H 11C O ty m _ x 'A Its eB :wl-W 1snYNX3 . S ii0. h 3SVNd f iHZ 'HYd .v¢ ranr�erti w+ Ztt 'LOUA N=V(l 2iQ1Ary KLMI'MY� M�. wasu'-. w ,.1-s+�ti.-:ii... .,:,r.-.-..,.,-„ s ....�.. « ,..., . t.••i.,-.+�-f...+a.w�.,.;w�.., .- r . . .e .,� _ -�. ]ti u �..'.y. ..-. .. I M1•i4e..Mn •�1 iu,.a try. .Y me � . .iu.1M � s. ti � .. ,� 'r.°,� M�S., wt-(:--:'� -_'S_. �. .L 1`C-X'. :as.f7- ". _-.. -.-_ -1.' - '1'- .... ;t-_.•Yl•.- �:�. - ,t -lr ..� `}F�'^ ,.;...., .�'_�}y,?+L. ..±•y<....�.'e��'`'P.itYti .R - •EI^" , - - -. 7.?p'.. .....- , ..- _ ..�,.e.:,i ,. =c4-,`�-'�'• ��"4d i _ �.�::tal:�n�!{Yz~tM�.•_es► •,.+.«�4�:-.�,.,'r ih�:M.At S'!aI• ♦N\ a....Yu.4Y.:� RsW 1yT.,iw_ , _; �_. -..1�...- w :.P �i'T WE.I>4 L=yAa<.J..�'.:w�w r. 4+: .. FILE COPY AdO3 1111 SCOPE OF WORK ` This is in reference to the design, installation, operation, testing and maintenance of pre- engineered, dry chemical fire extinguishing systems that discharge from fixed nozzles and piping by means of expellant gas, where applied in connection with hazardous storage facilities, spray paint booths, industrial or commercial applications to be protected as per both national and local codes and standards. All operating devices designed, located, installed, shall be protected so that they are not to be subjected to mechanical, environmental, or other conditions that could render it inoperable or cause inadvertent operation of the system. Where two or more hazards may be simultaneous involved in the fire by reason of proximity. The hazard shall be protected by individual systems installed to operate simultaneously, or a single system designed to protect all hazards that may be Y g Y g involved. An hazard that will allow firepropagation from one area to simultaneously y another shall constitute a single fire hazard. All systems must have both automatic and manual methods of activation. Automatic detection and system activation may consist of either electrical or fuse link type devices. Pipe and fittings will be of non-combustible materials having physical and chemical characteristics compatible with the dry chemical powder. Dry chemical containers and expellant gas assemblies shall be installed and located as to the accessibility for inspection, maintenance and charging. All fuel source shut down may consist of either electrical micro switch, pressure switch, mechanical gas valve or electrical solenoid gas valve. In case, Knight Fire Protection isn't supplying the device or material, Knight Fire Protection requires it be supplied and/ or installed by a licensed contractor, all materials shall be in accordance with the manufacturers listed installation and maintenance manual, and meet all codes and standards pertaining to the integrity, function and operation of the system designed and installed by Knight Fire Protection. Materials supplied by an outside source other than Knight Fire Protection have no warranties nor will Knight Fire Protection assume any liabilities stemming from their installation. A. Clarifications: 1. Its the owner responsibility to provide a UL listed paint spray booth and have approved by the authority having jurisdiction. 2. The booth, listed dampers, ducts and baffles devices shall be designed, constructed and installed to meet NFPA- 33, NFPA- 96 and local codes and standards. 3. The booth will be installed and approved by the local building department or Fire Marshal depending on authority having jurisdiction prior to the fire system installation. 4. The extinguishing system, if provided, will be connected to the alarm system in accordance with the requirements of NFPA - 72 National Fire Alarm code and local standards, so that the activation of the extinguishing system will sound the alarm as well as provide the function of the extinguishing system. 5. The spray booth and its installation is sufficient to support the installation of the fire suppression system. 6. All work to be performed during normal business hours unless agreed to by Knight Fire Protection. 7. The work area is to be accessible at all times during the system installation. 8. Any added time or travel due to construction, electrical work, gas piping, and/or any re-scheduling will be in addition to the proposed bid. 9. Changes in the booth design and construction or fire protection criteria after acceptance of this proposal will be reflected in an increase or decrease in the form of a contract change order. B. Exclusions: 1. Installation and connecting of all electrical devices, alarm system, and fan shut- down unless contracted to do so. ■ OPEN FACE PAINT SPRAY BOOTH rom PROTECTION Chem A L 1 aINTERNATIONAL LTD.COMPANY MONARCHTM INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL • COMPONENTS • DESIGN • INSTALLATION • MAINTENANCE Manual No. PC98201 Chapter 1 —General Page 1-1 s ' CHAPTER I General Information INTRODUCTION Pyro-Chem Open Face Paint Spray Booth automatic dry chemical fire suppression system is of the pre-engineered type as defined by the NFPA Standard for Dry Chemical Extinguishing Systems, NFPA-17. The extinguishing units described in this manual are intended to be installed, inspected, and maintained in accordance with NFPA-17. Limitations detailed in this manual have been established through extensive testing by Underwriters Laboratories, Inc. Installation and maintenance of the system must conform to the limitations detailed in this manual and be performed by an Authorized Pyro-Chem dealer. The Pyro-Chem Open Face Paint Booth System utilizes a monoammonium phosphate based dry chemical agent (specifically designed to suppress carbonaceous solid, liquid, gas or electrical fires). The system provides mechanical or electrical automatic actuation and can be manually actuated through a remote mechanical pull station. Upon actuation, the system discharges a pre-determined amount of agent to the hazard area. The shutdown of fuel and power to the hazard area is required upon system actuation. Exhaust fan(s) in the ventilation system must be shut off during system discharge to allow the proper concentration of agent to build up in the hazard area. The Pyro-Chem Open Face Paint Booth System is designed to accommodate a mandatory factory pre-set time delay. This time delay is required based on the UL 1254 compliance testing. TEMPERATURE LIMITATIONS The operating temperature range of the Pyro-Chem Open Face Paint Booth System is 32 °F (0 °C) minimum to 120 °F (49 °C) maximum. UL LISTING The Pyro-Chem Open Face Paint Booth Industrial Fire Suppression System has been tested to the UL Standard for Pre-Engineered D[y Chemical Extinguishing System Units. UL1254 (Revised Sept. 29, 19981, and Listed by Underwriters Laboratories, Inc. UILEX 3437 CEx732 September 29, 1998 Chapter 2—Components Page 2-1 s ' CHAPTER II COMPONENTS CYLINDERS & VALVE Pyro-Chem Open Face Paint Spray Booth automatic dry The valve shown in Figure 2-2 is a pressure sealed, poppet chemical systems are supplied in 15 pound, 25 pound, type valve. It is on all cylinders and also the PAC-10 and the 35 pound, 50 pound, and 70 pound capacity cylinders. They PAC-200 cylinders. The valve discharge port is 3/4" NPT. are the Models PCI-15ABC, PCI-25sABC, PCI-35ABC, PCI-50sABC, and PCI-70ABC. Each cylinder must be sepa- rately piped to its own nozzles. All models are charged with dry nitrogen to 350 psi @ 70' F. These systems are for indoor hazard protection only. All are rated to protect "A", "B", and "C" Class Hazards. The dimensions of the cylinders and valve assemblies are shown in Figure 2-1. The cylinder is manufactured, tested, and marked in accordance with DOT specification 413350. R MOUNTING BRACKET MODEL NO. A B C D WEIGHT USED C PCI-15ABC 6.00 21.75 27.50 19.00 30lbs. MB-15 B PCI-25sABC 8.00 24.75 30.50 22.00 58lbs. MB-15 D PCI-35ABC 10.00 30.00 35.75 27.75 71 lbs. M8-1 PCI-50sABC 10.00 30.00 35.75 27.75 86lbs. MB-1 PCI-70ABC 12.00 34.75 40.5 32.5 130lbs. MB-1 ALL DIMENSIONS IN INCHES t— A Figure 2-1 Cylinder and Valve Assemblies ITEM PART NO. DESCRIPTION 1 VALVE BODY 9 5 2 490-020870 DRY VALVE CAP & STEM ASSY 3 4 1 3 385-020002 CONICAL SPRING 6 4 975-320261 RETAINING WASHER 5 733-020024 E-RING 6 732-020025 PRESSURE GAUGE 7 240-002026 HIGH TEMPERATURE RELIEF PLUG 2 8 325-020029 VALVE BODY O-RING 8 9 741-020805 PISTON 10 325-020636 PISTON O-RING Figure 2-2 Valve Cross Section 302842PC ULEX 3437 CEx732 September 29, 1998 Chapter 2-Components Page 2-3 s MODEL ECH — ELECTRIC CONTROL HEAD The Model ECH electric control head is an electrically oper- ated control head which can be connected to the PCI-15/25s/35/50s/70 cylinder valve. This control head will support an electric thermal detection system, a remote ° mechanical pull station (Model RPS-M), and a mechanical or O electric gas shutoff valve. It will not support a fusible link ° O detection system. A miniature electric switch (Model MS-DPDT) is included. The Model ECH control head is available in both 120 VAC (Model ECH-120) and 24 VDC (Model ECH-24). It is equipped with a local manual control handle that allows for mechanical system actuation. Figure 2-7. Model MB-P2 - Control Head Operation of the local manual control requires removing the Mounting Bracket. pull pin and rotating the handle clockwise. The Model ECH 1026<6PC control head can actuate a maximum of three (3) cylinders. See Figure 2-6. PNEUMATIC ACTUATING o CYLINDERS 0 1. Model PAC-1 0. 0 SET FiREO . R LIRN The Model PAC-10 is a pneumatic actuating cylinder that iNORELE/SEFiRE s.sEw 0 can actuate a maximum of ten (10) agent cylinders simulta- Model ECH Ex.Rc�s.R� neously. The Model PAC-10 includes a DOT 46350 cylinder Contml Head pressurized with dry nitrogen to 350 PSIG @ 701 F., a brass ' valve with pressure gauge, and a wall mounting bracket. A ® Model MCH, NMCH or ECH control head must be purchased separately and connected to the PAC-10 to open the valve. Figure 2-6. Electric Control Head. See Figure 2-8. MODEL ECH MODEL NMCH — MECHANICAL CON- (SOLD SEPARATE Y) TROL HEAD The Model NMCH Mechanical Control Head is a fully - - mechanical control head which can be connected to the PCI- x r 3/4" DISCHARGE 15/25s/35/50s/70 cylinder valve. This control head will sup- PORT port a fusible link detection system, a remote mechanical pull station (Model RPS-M), and a mechanical or electric shut-off valve. A miniature electrical switch (Model MS-SPDT 20.25 or MS-DPDT) can be ordered separately and field installed. There is no local manual actuation for the Model NMCH. 14.50 The Model NMCH control head can actuate a maximum of 712.25 three (3) cylinders. The Model NMCH can be used as a direct replacement for the Model MCH. MODEL MB-P2 - CONTROL HEAD --I 4.00 MOUNTING BRACKET Figure 2.8. Model PAC-10 Pneumatic Actuating Cylinder. The Model MB-P2 mounting bracket must be used to mount the Model MCH, NMCH or ECH control head if the control head is not mounted directly on a cylinder valve. See Figure 2-7. ULEX 3437 CEx732 September 29, 1998 Chapter 2—Components Page 2-5 DETECTION EQUIPMENT 3. Model FLH-1. 1. Model FLK-1. The Model FLH-1 fusible link hanger is an accessory designed to simplify the installation of fusible links in the fusible link line. It can be used with the Model FLK-1/1A The Model FLK-1 fusible link kit includes a 10" steel bracket, fusible link kit (kits must be ordered separately). The two (2) 1/2" EMT connectors, four (4) cable crimps, and two Fusible Link Hanger makes it possible to install fusible links (2) "S" hooks. Fusible links must be ordered separately. without cutting and crimping loops in the fusible link line for See Figure 2-10. each link. They are available in packages of 25 (FLH-25) only. See Figure 2-11. 2. Model FLK-1 A. The Model FLK-1A fusible link kit includes an 8" steel brack- et, two (2) 1/2" EMT connectors, four (4) cable crimps, and two (2) "S" hooks. Fusible links must be ordered separately. LINK DETECTOR BRACKET TERMINAL LINK SHOOK 1/2"EMT CONNECTOR 3/64"OR 1/16"STAINLESS STEEL CABLE FUSIBLE LINK CABLE CRIMP SERIES LINK Figure 2-10. Model FLK-1 Fusible Link 002849PC FUSIBLE LINK KIT (SOLD SEPARATELY) FUSIBLE LINK (SOLD SEPARATELY) FLH-1_T FUSIBLE LINK HANGER Figure 2-11. Model FLH-1 Fusible Link Hanger 002850PC ULEX 3437 CEx732 September 29, 1998 Chapter 2—Components Page 2-7 GAS SHUTOFF VALVES 2. Electric Gas Shutoff Valve. 1. Mechanical Gas Shutoff Valve. A gas shutoff valve is required on all systems used to pro- tect a gas fueled appliance to stop gas flow in the event of system actuation. A UL Listed electric gas valve can be A gas shutoff valve is required on all systems used to pro- used with either the Model MCH, NMCH or ECH control tect a gas fueled appliance to stop gas flow in the event of head. The valves are rated for natural and LP gas. Valves system actuation. A mechanical gas valve can be used with are available in 120 VAC. Electric gas valves are available either the Model MCH, NMCH or ECH control head. It is in the following sizes: connected to the system control head by stainless steel cable. This cable is enclosed in 1/2" EMT with a corner pul- Maximum ley at each change in direction. The valves are rated for Valve Operating natural and LP gas (see Figure 2-14). Mechanical gas Model No. Size Pressure valves are available in the following sizes: EGVSO-75 3/4" 50 psi Maximum EGVSO-100 1" 25 psi Valve Operating EGVSO-125 1-1/4" 25 psi Model No. Size Pressure EGVSO-150 1-1/2" 25 psi GV-75 3/4" 5 psi EGVSO-200 2" 25 psi GV-100 1" 5 psi EGVSO-250 2-1/2" 25 psi GV-125 1-1/4" 5 psi EGVSO-300 3" 25 psi GV-150 1-1/2" 5 psi Note: A UL Listed manual reset relay is required when using GV-200 2" 5 psi an electric gas valve. The Pyro-Chem Model SM-120 sole- GVSO-250 2-1/2" 5 psi noid monitor may be used for this purpose. GVSO-300 3" 5 psi CORNER PULLEYS 1. Model MCP-1. A corner pulley is used whenever a change in stainless steel 0 o cable direction is required. The Model MCP-1 corner pulley Pyro Chem is equipped with a set screw fitting for connection to 1/2" GAS VALVE SHUT-OFF EMT. See Figure 2-15. 1.925---i o O r,r-n F=,,71\ Figure 2-15. Model MCP-1 Corner Pulley. 002855PC Figure 2-14. GV-Series Mechanical Gas Valve. 002853PC ULEX 3437 CEx732 September 29, 1998 Chapter 2—Components Page 2-9 � I ELECTRICAL SWITCHES MODEL SM-120/24 SOLENOID MONITOR 1. Model MS-SPDT. The Model SM-120/24 solenoid monitor is used in conjunc- The Model MS-SPDT is a miniature electrical switch which tion with the Model ECH control head to supervise the actu- can be field mounted in the Model MCH, NMCH, or ECH ation and detection circuits. In the event of a problem in the control head. When used with the Model MCH or NMCH circuit, a light on the monitor goes out. The Model SM-120 is control head, it provides one set of NO/NC dry contacts. It is used with the Model ECH-120 control head. The Model intended for use with electric power shutoff devices (dealer SM-24 is used with the Model ECH-24 control head. Two supplied), electric gas valves, alarms, bells, lights, contac- sets of NO/NC dry contacts are provided. The unit mounts tors, and other electrical devices designed to shut off or turn directly to a three gang wall outlet box. The Model SM-120 on upon system actuation. The switch is rated for 20 amps acts as a reset relay when used with an electric gas valve. ® 125/250 VAC, 1/2 hp ® 125 VAC, and 1 hp Q 250 VAC. Electric gas valve wiring instructions are provided in the See Figure 2-19. installation section of this manual. See Figure 2-21. Pyro-Chem SOlenolo Monitor uc;«r c:rvcrx:ut rvcxaw i g1b11C nFSE* I ® 0 Figure 2-19. Model MS-SPDT Miniature Switch. 002858PC 2. Model MS-DPDT. 0 0 The Model MS-DPDT is a miniature electrical switch which can be field mounted in the Model MCH or NMCH control head and is included in the Model ECH control head. When used with the Model MCH or NMCH control head, it provides two sets of NO/NC dry contacts. When used with the Model 0 0 0 ECH control head, it provides one set of NO/NC dry con- tacts. It is intended for use with electric power shutoff Figure 2-21. Model SM-24/120 Solenoid Monitor. devices (dealer supplied), electric gas valves, alarms, bells, 00286OPC lights, contactors, and other electrical devices designed to shut off or turn on upon system actuation. The switch is PIPE & FITTINGS rated for 20 amps ® 125/250 VAC, 1/2 hp @ 125 VAC, and 1 hp @ 250 VAC. See Figure 2-20. Pipe and fittings must be furnished by the installer. Schedule 40 black, galvanized, chrome plated, or stainless steel pipe must be used. Standard weight malleable, galva- nized, chrome plated, or stainless steel fittings must also be used. Figure 2-20. Model MS-DPDT Miniature Switch. 002959PC ULEX 3437 CEx732 September 29, 1998