HomeMy WebLinkAboutBLD2012-00294 Addition - BLD Permit / Conditions - 6/7/2012 Inspection Line(360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
Shelton, WA 98584
too
RESIDENTIAL BUILDING PERMIT BLD2012-00294
OWNER: RICH HUISINGH RECEIVED: 5/4/2012
CONTRACTOR: LICENSE: EXP: ISSUED: 6/7/2012
SITE ADDRESS: 7340 W SHELTON MATLOCK RD SHELTON EXPIRES: 12/7/2012
PARCEL NUMBER: 420181100020
LEGAL DESCRIPTION: TR 2 OF NE NE
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
ADDITION OF UNHEATED UTILITY/STORAGE AREA AND COVERED
PORCH AND REMODEL THE MAIN STRUCTURE ORIGINALLY
PERMITED BLD2005-00127
General Information Construction&Occupancy Information Square Footage Information
No. of Bedrooms: 3 Type of Constr.: VB
Type of Use: SF Insp.Area: No. of Bathrooms: 1 Occ. Group: R-3 Lot Size: Deck:
Type of Work: ADD Fire Dist.: 12 No. of Stories: 2 Occ. Load: Building:160
Valuation: $ 38,990.10 Building Height: 0 Occ. Status: Primary Basement: cov porch 95
Manufactured Home Information Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body:
SEPA?:
Model: Width: Ft. Rear: Ft. Slope: Ft.Side 1: Ft. Shoreline Desig.:
Year: Serial No.: Side 2: Ft. I Comp. Plan Desig.:
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Water Closets (Toilets) 1 Dryer Vent 1 Plan Check Fee TW 5/4/2012 $346.22 S1201200000001
Lavatories 1 Exhaust Hood 1 Planning Review Fee TW 5/4/2012 $205.00 S1201200000001
Bath Tubs 1 Ventilation Fan 2 EH Plan Review MRB 5/4/2012 $ 103.00 S6201200000001
Water Heaters 1 Building State Fee LDK 5/22/2012 $4.50 S1201200000001
Clothes Washer 1 Building Permit Fee LDK 5/22/2012 $532.65 S1201200000001
Kitchen Sink 1 Mechanical Permit Fee LDK 5/22/2012 $40.20 S1201200000001
Dishwasher 1 Mechanical Base Fee LDK 5/22/2012 $28.50 S1201200000001
Hosebibs 2 Plumbing Permit Fee LDK 5/22/2012 $67.10 S1201200000001
Plumbing Base Fee LDK 5/22/2012 $24.70 S1201200000001
Total $ 1,351.87
BLD2012-00294 Please refer to the following pages for conditions of this permit. Page 1 of 5
CASE NOTES FOR
BLD2012-00294
CONDITIONS FOR
BLD2012-00294
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-098z The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
x Rig VT
2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
x R b k+
3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Department ,priorany further inspections being performed or approvals granted.
4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
( 4
��_
5) All replacement windows shall be installed per manufacturer's specifications and be flashed per IRC section R703.8. All installations shall meet
requirements for guards per R613 and safety glazing per R308.4. WSEC requires a U-factor of.30 or less in all heated spaces. Existing,
non-conforming, egress window openings are not required to be enlarged, but it is highly recommended. Egress windows replaced in an existing opening
shall be brought into compliance with current codes if a product is available for this application. Building plans/permit are required for windows in new,
enlarged or relocated openings these installations must meet all current codes.
Windows and doors shall be installed in accordance with the manufacturer's written installation instructions and shall be available during inspections.
X
6) All wall cavities serving as exterior walls, exposed during construction or remodeling work shall be insulated to the full depth of the wall cavity and
inspected prior`tq covering. Insulation R-values shall be as follows: 2x4 wall cavities min. R-15 and 2x6 wall cavities min. R-21.
6 or
X ki-
7) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X Q[�
BLD2012-00294 Please refer to the following pages for conditions of this permit. Page 2 of 5
8) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Xuilding DepV ,`,prior to any further inspections being performed or approvals granted.
9) Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option III, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors
(Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38 advanced or R-49 standard, Vault Insulation R-38,
and Slab Insulation R-10.
In addition the following credit from Table 9-1 shall be completed: 6
X ? `
t A-
10) A minimum of 50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSEC
Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall
be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s)with integral photocontrol photosensor or
installed in or around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps).
Reference 1�VS�C 505.
X }�o
11) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the
manufacturer's installation instructions.
X Q \-�
12) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered.
A. Drainfield/ Reserve requires a 10ft setback from all footing/foundations.
B. Septic tank(s) requires 5ft setback from all footing/foundations.
C. No foundatiains within 30ft, down gradient of drainfield/reserve area.
x R�on r
13) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other
vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2).
X 1�.it �}-
14) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revoc9ttionn `l
X
BLD2012-00294 Please refer to the following pages for conditions of this permit. Page 3 of 5
15) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
) R D \�
16) Placement of stru�cttulemust comply with standards set forth per the international codes regarding descending and/or ascending slopes.
17) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
X
rdinance or regulation, must be reviewed and approved by Mason County prior to construction.
18) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall be made prior to requesting additional inspections.
X .t A
19) All property lines shall be clearly identified at the time of foundation inspection. X R A 14
20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinanc s and building regulations.
X
21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
(older have pr ventgd action from being taken. No more than one extension may be granted.
22) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
X connectors, anted flaashigg. Install metal connectors approved for contact with the new types of pressure treated material.
23) Retaining walls needed to support a surcharge such s structures, roads, or to support slopes, shall require a separate building permit and approval prior
to construction of the retaining wall. X T2 �1
BLD2012-00294 Please refer to the following pages for conditions of this permit. Page 4 of 5
24) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure
these structures meet the setback conditions listed.
x ?-z�+
25) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
x 'Rfl
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any
time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be
occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate
and grants employees of Mason County access to the abome described property and structure for review and inspection.
OWNER OR AGENT: DATE: (I -7 I Z
BLD2012-00294 Please refer to the following pages for conditions of this permit. Page 5 of 5
to
2
o CONCRETE MECHANICAL MANUFACTURED HOME c
o Date fS Z611� By _'" N
N Footings I Setbacks ' Ribbons Z
Gas Pip ng
o Interior Date By Interior-Date By Date By
Exterior Date By Exterior-Date By
Sot-up =
Point Load I Isolated Footings INSULATION Date By 22
BG f SLAB INSULATION - - n
Date By Data By FIRE DEPARTMENT 2
Foundation Walls Floors Date By
Date By Data By DECKS
FRAMING waif trt.Sri, �^ � z t-'8�'- Date By
Date j� Bye Data 9 �f �/ ey PROPANE TANKS
PLUMBING Vault 0010JA Date 13y
Date 9��y, S`-' By OTHER
Groundwork Attic c%'V 7 iw
Data By Date B y Type-
Date By
D.w.v DRYWALL Type.
-0 Date 6y Int.Brace Wall Date By
w Date By FINAL INSPECTION p
w Water Line Fire Separation N
CD , /n1
m Dale B V Date By Date I Z V I By ! IL O
i5
N
g Pass or Request I nspect.
Type of insp. Fail Date Date Done By Comments
o n �
! i w� t.�>re� P>L z t /3 Z l , �3 2, k- U�t,��.�-t�- C
N
O !J' vj
-177
0)
CD
3
RX I< LAO ed rc�
"VA V
PCILK
ww 1 45
0
0
0
Permit#ZO Dd09/ MASON COUNTY
BUILDING Ill 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location '3 y0 1A) ::5" A�
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
f und' Items listed below ust a corrected to gain compliance
14 i lr
241- 6tZIlW 41 I L1P_ Q S
You are hereby notified that the above corrections shall be made
BEFORE PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office
Make corrections, items will be checked on next inspection regarding possible structural
❑ OK to damage incurred by recent
This is not a complete inspection J�p %,�� �r/r�ia;ya�- ifi� "na disasters.
This
made"
�f disasters.This is NOT a
Date L, - /P ,/� Department CORRECTION NOTICE.
f�—
Inspector
10* 4 N*IT * ; ' THIa TAFMIllLy
Permit#
MASON COUNTY
BUILDING 111 426 W, CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location %-�'11CJ L AJ S'/yZ,/ ie�/✓-" Ileil?e c,, C.It R-b
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found: Items listed below must be corrected to gain compliance
You are hereby notified that the above corrections shall be made
BEFORE PROCEEDING WITH ANY FURTHER WORK
Call for re-inspection when corrections are made before continuing ❑ please contact our office
❑ Make corrections, items will be checked on next inspection regarding possible structural
❑ OK to damage incurred by recent
"natural/man made"
❑ This is not a complete inspection disasters. This is NOT
Date �! ` /.� CORRECTION NOTICE.
Department
Inspector
a* ,# NvsT P ivlovV ' TH1 ,4b, TA* 4
MASON COUNTY PERMIT 1 L Z--� l
BUILDING PERMIT APPLICATION
426 W. Cedar•P.O. Box 1 B6, Shelton,WA 98584
Shelton (360) 427-9670•Beffafr(360)275-4467•Elma(360)482-5269
On the web www.co.mason.wa its
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner ,R;�Lh i e Cr v a C K n Company Name
Maing Address t t OR-It Mailing Address
City b,e-1 k n State�7lp Code q '�` Cry State Zip Code
Phoneme�-.)O- 71i1 -63 Z-3 Other Ph.�LC- 2 0-2 1 b 3 Phone Other Ph.
Lien/Trtie Holder "')A#, Contractor Reg. Exp.
E Mai[Address
E mail address Drivers Lic.# DOB
SEPTIC/WATER SYSTEM INFORMATION -Connect to New Septic E�dsting Septic
Connect tp-Water System Name of Water System
Well ✓ Water System Name of Water System
PARCEL INFORMATION-12 Digit Parcel No - Fire District
Legal Description
6 Site Address(Please include street name,street number and city) •
Directions to site
Will tim er e cut and sold in parcel preparation?Yes/No
Is prop within 200'of Saltwater Lake River/Creek Pond
Weti Seasonal Runoff Stream Slopes or Bluffs > 15%
Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?YesJNo
TYPE OF JOB-New Add X Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑
Use of Building 5'`�+\t �,;l`� t7�ct seribe Work- &Mo I G��`lr 4 _ + ar c-d- co.yQ;�eo Pc rc.h
No. of Bedrooms Z No.of Bathrooms I Square Footage-1st Floor 1�O 2nd Floor
3rd Floor Basement Deck Covered Deck q—Other Sq.ft. 110
Garage Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION -Make Model Year
Le Width Serial No. No.of Bedrooms, No_of Bathrooms
T e f Heat Purchase Price$ Replacement Unit? Yes/No
1 sfaller Name Certification No.
O�R�IEf3J BUQDff Admow{aiges submission of asap�Iomon may result in a stop v�ric order or pem ut reva:a�on �lmowiedgement of
suer is try sigrBhae belovu I declare that I am the ovrrrs,owrrrs represerdadive,or the cork I further declare that 1 am entitled to remove this
perruT and to do the work as proposed the appficafion I declare that I have o'ut�ed the perm ssion from all the neary parfies tf permission Is
required from any easemerrt holder,or any other party in regarding this appfication or the work prop el the apprrca5on,l have obtained
permission from them to apply for this pxrrd and conduct the work proposed. The owner or agerd on owners behalf,represents that the irrfomabon
provided is a=Aate and grants employees of Mason County access to the above described property and structue for review and inspection.
PROOF OF CO 9F WORK IS BY MEANS OF A PROGRESS INSPECTION.
X N,�� Date: �lo�I Z
�
Owner/owners Represrntafive/Contractor (in1cate which one)
FOR OFFICIAL USE BEYOND THIS POINT Accepted by. Date J
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department Zz u0�
Planning Department
Environmental Health Department
Public Works Department
Fire Marshal
FEES
BuIld'ing Permit Fee Site Inspection
Plan Review Fee EH Review Fee
Plumbing&Base Fee Planning Review Fee
Mechanical&Base fee Other
Wood/Gas/Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal
Valuation$ TOTAL FEES
zo
op co ort4
v i
I
1 G'3 i
� ti � ems_ � • . No�SQ.. - b�
1 t'u
---------------
A�
Ad