Loading...
HomeMy WebLinkAboutFire Safety Report - FIR Inspections - 12/16/1998 1 MASON COUNTY FIRE MARSHAL Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,Washington 98584 (360)427-9670 Ext.273 CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION December 16, 1998 NIMROD CLUB FIRE SAFETY INSPECTION REPORT A fire safety inspection of the Nimrod Club was conducted on 12/15/98. CURRENT STATUS: A 4026 square foot, V-N building. The building is approximately 50 years old. Primary use appears to have been an assembly occupancy, used for community and private organization meetings, and periodic food preparation service. Based on past and current use, the assumed occupancy classification is A-2.1 . PROPOSED USE: The applicant wishes to use the building as a dancing, dining and drinking establishment. It appears that under the 1997 Uniform Building Code, this proposed use is consistent with the assumed occupancy classification, and therefore would not constitute a change of use. On December 4, 1998, the applicant attended a pre-application meeting and presented a proposed interior floor plan that would the include the creation of areas for dancing, dining, and liquor consumption. Interior remodeling would include some counter-height walls to define use areas and the installation of cooking appliances. FIRE CODE REQUIREMENTS: 1 . Provide lighted exit signs, hard-wired into a circuit, over each exit door. 2. Provide two (2) battery-backup emergency lights. One in the dancing area and one in the lounge/dining area. 3. Provide panic hardware on all three exit doors.