HomeMy WebLinkAboutFire Alarm Reports - FIR Inspections - 4/8/2004 Mason County Fire Marshal Inspection Contract No.
Mason County Bldg. III File No.
426 W. Cedar
PO Box 186
Shelton WA 98584
FIRE ALARM SYSTEM
REPORT OF INSPECTION
Date: c��0 c�
Name of Facility: Church of the Nazarene
Occupied as: Church
Address: E 1331 Shelton Springs Rd.
County: Mason Zip: 98584 Telephone:
Building Designation (if more than one building)
Inspection by: ID&4&1 Title: Tech.
Date of Inspection: ui — 95 01-\
1 . Type of Test: Monthly [ ] Quarterly [ J Semi-Annual [ ] Annual [X]
2. Type of system: Noncoded [X] Common coded [ ] Selective coded [ J Dual Coded [ ]
(as pertaining to Chapter 212-14 WAC)
3. Local Fire Department:
4. Fire Department Official Contacted:
5. Test Received at Alarm Center: 0 Yes [ ] No
6. Master Box Reset AM 1 Z i CMG PM
7. All Tests Satisfactory �C], Yes ( ] No
8. Comments, explanation of unsatisfactory results, action taken, etc.
tj 14
Original Form to be returned to Fire Marshal
r �pd
N
�—° 15 2004 i
APR EQUIPMENT TESTED
SEViVof Units Test Satifactory
Type of Equip m Tested Date Yes No N/A Type and Manufacturer
9. Control Panel 1 q 4Oq Silent Knight 5204
10. Manual Station 6 `� ',�,-
11. Heat Detectors & �a�o
12. Smoke Detectors 6
13. Audible Alarm Devices 6 v
14. Visual Alarm Devices 6 /o
15. Code Transmitters X
16. Automatic Door Releases X
17. Trouble Indicators 1
18. Master Alarm Box
19. Batteries 2 9���
20. Charger 1 �� Y�o rarer
21 . Generator X
22. Ventilation Control X
23. Fire Dept Interconnection
24. Central Station Interconnection 1 -'
25. Ext Sprinkler Elec Alarm Bell X
26. Sprinkler Water Flow Switch X
27. Sprinkler Gate Valve Super Switch X
28. Annunciators X
29. Automatic Time Delay of General Alarm — Minutes. None Installed [ ].
30. Test of alarm system on emergency power, satisfactory? (kYes [ ] No
31 . This is to certify that this fire alarm system has been properly inspected for reliability covering
the items listed in this report and is consistent with NFPA fire alarm Maintenance Standards.
A. Signature of Owner or Representative :
B. Signature of Fire Alarm Firm Repesentative T)a��j
C. Name of Firm: PIONEER FIRE & SECURITY
D. Mailing Address: PO Box 597, E. Olympia, WA 98540-059 Phone No. 360-491-8141
E. Electrical Contractors License #: PIONEFS088LR
Original Form to be returned to Fire Marshal
Mason County Fire Marshal Inspection Contract No.
Mason County Bldg. III File No.
426 W. Cedar
PO Box 186
Shelton WA 98584
FIRE ALARM SYSTEM
REPORT OF INSPECTION
Date: ly - OF— �
Name of Facility: 1G�Z�R Fiy� C�`�f��-
Occupied as: C G
Address: . /
County: M61 Zip: ) p5 Telephone:
Building Designation (if more than one building)
Inspection by: � ' ` Title: Tech.
Date of lnspectio . 10 it -( — y (
1. Type of Test: Monthly [ ] Quarterly [ ] Semi-Annual [ ] Annual [X]
2. Type of system: Noncoded [X] Common coded [ ] Selective coded [ ] Dual Coded [ ]
(as pertaining to Chapter 212-14 WAC)
3. Local Fire Department:
4. Fire Department Official Contacted:
5. Test Received at Alarm Center: [ Yes [ ] No
6. Master Box Reset AM PM
7. All Tests Satisfactory [ Yes [ ] No
8. Comments, explanation of unsatisfactory results, action taken, etc.
Original Form to be returned to Fire Marshal
EQUIPMENT TESTED
# of Units Test Satifactory
Type of Equipment Tested Date Yes No N/A Type and Manufacturer
9. Control Panel
10. Manual Station
11 . Heat Detectors
12. Smoke Detectors ° X
13. Audible Alarm Devices 'klo�
14. Visual Alarm Devices �� k
15. Code Transmitters
16. Automatic Door Releases k
17. Trouble Indicators °P /
18. Master Alarm Box
19. Batteries
20. Charger d
21. Generator k
22. Ventilation Control
23. Fire Dept Interconnection x
24. Central Station Interconnection 0
25. Ext Sprinkler Elec Alarm Bell
26. Sprinkler Water Flow Switch 5C
27. Sprinkler Gate Valve Super Switch X
28. Annunciators
29. Automatic Time Delay of General Alarm Minutes. None Installed [ J.
30. Test of alarm systern on emergency power, satisfactory? [X Yes [ ] No
31. This is to certify that this fire alarm system has been prop rly inspected for reliability covering
the items listed in this report and is consistent with NFPA fire alarm Maintenance Standards.
V 1
A. Signature of Owner or Representative
B. Signature of Fire Alarm Firm Repesentative
C. Name of Firm: PIONEER FIRE & SECURITY
D. Mailing Address: PO Box 597, E. Olympia, WA 985A0-0597 Phone No. 360-491-8141
E. Electrical Contractors License #: PIONEFS088LR
Original Form to be returned to Fire Marshal
MASON COUNTY FIRE MARSHAL
Mason County Bldg. III 426 W.Cedar
P.O.Box 186 Shelton,Washington 98584
(206)427-9670
CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION
FIRE ALARM SYSTEM
REPORT OF INSPECTION
Date:
Name of Facility: Church of The Nazarene - Shelton
Occupied As: A rh„rrh
Address: F. 133m Shelton Springs Rd City: _ Shelton WA: 98584
County: Mkacnn Zip: 985,94 Telephone: 1366 426-1298
Building Destination (if more than one building):
Inspection By: zs e: 5�, ,� ' Title: Tech Date of Inspection:d��p5�. �
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1. Type of Test: Monthly [ ] Quarterly [ ] Semi-Annual [ ] Annual [x]
2. Type of System: Noncoded [ ] Common coded [ ] Selective coded [ ] Dual coded [ ]
(as pertaining to Chapter 212-14 WAC)
3. Local Fire Department: 360-426-4441
4. Fire Department Official Contacted:
5. Test Received at Fire Department?: Yes [ ] No ( ]
6. Marx Reset A.M. `." P.M.
7. Comments, explanation of results, action taken, etc.
ALL TESTS SATISFACTORY �C� Yes [ 1 'No
MCFMO 03-5/93
EQUIPMENT TESTED
NUMBER
OF SATISFACTORY CHECK
UNITS TEST TYPE AND
TYPE OF EQUIPMENT TESTED DATE YES jNO=N/A MANUFACTURER
8. Control Panel
9. Manual Station /y, 0
10. Heat Detectors F� 9
1 1 . Smoke Detectors
12. Audible Alarm Devices 05
13. Visual Alarm Devices
14. Code Transmitters �C
15. Automatic Door Releases
16. Trouble Indicators -0140
17. Mastef-Ahafm Box
18. Batteries 0Z X PA,NFL,
19. Charger
20. Generator
21 . Ventilation Control
22. Fire Department
Interconnection
23. Central Station
Interconnection
24. Exterior Sprinkler Electric
Alarm Bell
25. Sprinkler Water Flow Switch
26. Sprinkler Gate Valve
Supervision Switch
27. Annunciators
28. Automatic Time Delay of General Alarm Minutes. None Installed [ J
29. Test of alarm system emergency power, satisfactory? Yes [ No [ J
LEL
30. This is to certify that this fire alarm system has been properly inspected for reliability covering
the items listed in this report and is consistent with NFPA Fire Alarm Maintenance Standards.
A. Signature of Owner or Representative
C
B. Signature of Fire Alarm Firm Representative
C. Name of Firm Pioneer Fire & Securi y
D. Mailing Address P 0 Box 597, E Olympia, 98540 Phone No.
MASON COUNTY FIRE MARSHAL
Mason County Bldg. III 426 W.Cedar
P.O.Box 186 Shelton,Washington 98584
(206)427-9670
CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION
FIRE ALARM SYSTEM
REPORT OF INSPECTION
Date: zc—
Name of Facility: Church of The Nazarene - Shelton
Occupied As: n C`hiirr-h
Address: E 1331 Shelton Springs Rd City: Shelton WA: 98584
County:_ M ;Gnn Zip: qq R4 Telephone: ( 36d 426-1 s
Building Destination (if more than one building):
Inspection By: 6` 'S 2Z1�' Title: Tech Date of Inspection:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 . Type of Test: Monthly [ ] Quarterly [ ] Semi-Annual [ ] Annual 0
2. Type of System: Noncoded&Common coded [ ] Selective coded [ ] Dual coded [ ]
(as pertaining to Chapter 212-14 WAC)
3. Local Fire Department: 360-426-4441
4. Fire Department Official Contacted:
5. Test Received at Fire Department?: Yes [ ] No [ ] /y w
6. Master Box Reset l A.M. P.M.
7. Comments, explanation of results, action taken, etc.
ALL TESTS SATISFACTORY f � Yes l 1 No
MCFMO 03-5/93
EQUIPMENT TESTED
NUMBER
OF SATISFACTORY CHECK
UNITS TEST TYPE AND
TYPE OF EQUIPMENT TESTED DATE YES NO N/A MANUFACTURER
8. Control Panel
9. Manual Station _
D
10. Heat Detectors 2 �wW.4P-D
11 . Smoke Detectors
12. Audible Alarm Devices
13. Visual Alarm Devices �(7
14. Code Transmitters
15. Automatic Door Releases
16. Trouble Indicators 42;
1 7. Master Alarm Box
18. Batteries 7-1
19. Charger 1
20. Generator
21 . Ventilation Control
22. Fire Department
Interconnection
23. Central Station IPAAIA
Interconnection
24. Exterior Sprinkler Electric
Alarm Bell
25. Sprinkler Water Flow Switch
26. Sprinkler Gate Valve
Supervision Switch
27. Annunciators
28. Automatic Time Delay of General Alarm Minutes. None Installed]
29. Test of alarm system emergency power, satisfactory? Yes j No [ ]
30. This is to certify that this fire alarm system has been properly inspected for reliability covering
the items listed in this report and is consistent with NFPA Fire Alarm Maintenance Standards.
A
A. Signature of Owner or Representative B. Signature of Fire Alarm Firm Representative
C. Name of Firm Pioneer Fire & Security
D. Mailing Address P 0 Box 597 , E Olympia, 98540 Phone No. 9 ,,
PIONEER FIRE & SECURITY
P.O. Box 597 East Olympia, WA 98540-0597 (360)491-8141
Customer The Church of the Nazarene Account 24-3023
Address E 1331 Shelton Springs Rd. Dated 5/11/98
City Shelton State WA Zip 98584 Phone (360) 426-1298
Billing Address Same
1. PIONEER FIRE & SECURITY (7he Company) agrees to provide Annual inspection of the customer's fire
alarm system during the time this contract is in effect. Such inspections shall include the following:
a) Check and test master control panel operations.
b) Activate and check the required equipment each inspection:
Manual pull stations, Smoke detectors, Heat detectors,
Visual and sounding devices, Emergency power supplies, _Supervisory/detection switches
2. Customers shall pay $60.00. Said fee shall include all labor to perform each inspection as described
above.
3. This contract shall not cover the making of any repairs, nor furnish labor or material for said repairs. In the
event the inspection indicates the necessity of repairing the system,the customer shall approve all material and
labor costs prior to such work being performed.
4. The term of this contract shall be for Three years from the date of initial inspection
5. The Company does not guarantee or warranty that the service supplied will prevent fire or other occurrences,
or losses from such occurrences, and the Subscriber acknowledges that they are not entering into this
agreement with the expectations that The Company will insure or reimburse the Subscriber or any other person
for losses from such occurrences. The Subscriber agrees that 7he Company will have no liability for loss or
damage to property or for loss or damage to property or for personal injury or death due to any failure in the
fire alarm system or for interruptions of service because of(1) any failure to the Subscriber's alarm (2)any
defective or damaged equipment (3) strike of The Company's employees or employees of other, riots, floods,
acts of God, or any other causes beyond the control of The Company. If 7he Company should nevertheless be
found liable for loss of damage to persons or property irrespective of the cause because of negligent act or
negligent failure to act of The Company, its employees or agents, or on some other basis,the Subscriber
agrees that such liability is limited to a sum equal to one year's service charge of$250.00,whichever is
greater. The Subscriber agrees to and shall indemnity and save harmless The Company, its employees and
agents, for and against any claims, suits, losses, demands and expenses arising from any death of, or
injury to any person or property or any damage loss, for which The Company is not liable, or to the extent any
such claims, suits, losses, demands or expenses exceed the limits or The Company liability.
6. The Subscriber understands that the basic fees to The Company are based upon the service to be provided,
with due consideration to the scope, of 1'he Company's liability and are not related to the value of the
Subscriber's property or the property of others, in the Subscriber's premises.
Pioneer Fire & Security Date Authorized Signature Date