HomeMy WebLinkAboutCOM2000-00012 Demo Store and Construct Canopy - COM Permit / Conditions - 10/20/2000 MASON COUNTY PERMIT ASSISTANCE CENTER Inspection Line (360)427-7262
Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670, ext. 352
' Shelton, WA 98584
COMMERCIAL BUILDING PERMIT COM2000-00012
OWNER: AL JOHNSTON RECEIVED: 02/17/200
CONTRACTOR: AL JOHNSTON ISSUED: 10/20/200
SITE ADDRESS: 11900 N U.S. HIGHWAY 101 SHELTON EXPIRES: 04/20/200
PARCEL NUMBER: 420122200090
LEGAL DESCRIPTION: TR 9 OF NW NW EX
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
DEMOLISH EXISTING STORE AND CONTSTRUCT NEW 11900 HWY 101, SHELTON
CANOPY
General Information Construction & Occupancy Information
Type of Use: Insp. Area: 2 No. of Units: Type of Constr.:
Type of Work: NEW Fire Dist.: 11 No. of Bathrooms: Occ. Group: S3
Valuation: $ 44,750.00 No. of Stories: Occ. Load:
Building Height:
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
odel: Width: Building:
Year: Serial No.: Basement: Parking Spaces:
Setback Information Shoreline & Planning Information
Front: N 20.00 Ft. Shoreline: Ft.
Rear: S 65.00 Ft. Slope: Ft. Water Body: Shoreline Desig.:
Side 1: E 15.00 Ft. SEPA?: Comp. Plan Desig.
Side 2: W 15.00 Ft.
Fire Protection System Information
Auto Fire Alarm System?: Emergency Key Box?: Standpipe?:
Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?:
Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?:
COM2000-00012 Please refer to the following pages for conditions of this permit. 1 of 5
Plumbing Fixtures Mechanical Fixtures FEES
Type QtY. Type Qty. Type By Date Amoun Receipt
Plan Check Fee KLW 02/17/200 $100.00 52715
Adjust Plan Check Fee SKM 04/04/200 $244.34 54891
Building State Fee SKM 04/04/200 $4.50 54891
Building Permit Fee SKM 04/04/200 $529.75 54891
Non-Res.Energy Code DLC 04/06/200 $42.00 54891
Demolition Fee TW 04/06/200 $42.00 54891
Total $962.59
none
COM2000-00012 Please refer to the following pages for conditions of this permit. 2 of 5
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period
of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection
must be approved before building can be occupied.
OWNER OR AGENT: DATE: J
/"'
CASE NOTES FOR
COM2000-0001
1)
COM2000-00012 Please refer to the following pages for conditions of this permit. 3 of 5
CONDITIONS FOR
COM2000-00012
1) This application is subject to Buffer and Landscaping requirements as established under Mason County
Ordinance. For this type of business and the adjacent land uses, buffer requirements shall be 2 canopy trees, 4
understory trees and 6 shru r
et.
1.03.036.X
2) All upland areas disturbed dr newly eated by construction activities shall be ee vegetated or given an
equivalent type of erosion protectio (silt fencing or straw matting). X
3) Approved per dimensions and setbacks on submitted site plan. X
4) THE DEMOLITION AND DISPOSAL OF DEMO WEBRIS MU E R UIREMENTS AS PER
MASON COUNTY REGULATIONS. X
5) Approved per dimensions and setbacks on sub tt d to plan. X
6) All property lines sh I rly identified at the tim0f of foundation inspection.
X
7) CONSTRUCTION 0R,15CPS TO BE FIELD CORRECTED UIRED PER MASON COUNTY BUILDING
DEPARTMENT AND UNrrORM BUILDING CODE.x AV 9
8) Changes to approved building plans that affect compliance t th urrent non-residential Energy Code (NREC),
ventilation and Indoor Air Quality Code (VIAQ) Uniform Building lumbing/Mechanical Codes and/or Mason
County Regulations"T17
approved prior to construction.
X
9) Proposed stru'611tre o portions thereof with an projection over 30" in height from grade line, must maintain a 5'
separation sta e t een adjacent structures and that furthest projection.
X
10) ALL CON T CTI MUST MEET OR EXCEED ALL LOCAL CODES AND UBC REQUIREMENTS AND
OCCUPANCY IS L ITED TO THE PERMITTED ANQ APPROVED CLASSIFICATION. ANY CHANGE OF
USE OR OCCUPANCY WOULD RESULT) �IV EVOCATION. CHANGE OF USE MUST BE
APPROVED PRIOR TO CHANGE. x
11) Any changes in construction shall be revie a by gineer of record and submitted in writing to the Mason
County Building Department prior to construction. All engineering documents are a part of the approved set of
plans and must remain attached thereto. If engineering documents are removed, approval will not be granted.
In addition, a re-inspection fee of$42.00 per hour(minimum 1 hour)will be charged and must be collected by
this department prior to any further inspections being performed or approval granted.X
12) The approved plot plan is required to be on-site for inspection purposes. If inspection is called for and plot plan
is not on site, Approval WILL NOT be granted. In addition a Re-Inspection fee in the amount of$42.00 per
hour(minimum 1 hour) will be charged and must b t y this department prior to any further inspections
being performed or approval granted. X
13) All approved plans are required to be on-site for insp cti purposes. If inspection is called for and plans are
not on site, Approval WILL NOT be granted. In additio , a R -Inspection fee in the amount of$42.00 per hour
(minimum 1 hour) will be charged and must be co c b his department prior to any further inspections
being performed or approval granted. X
COM2000-00012 Please refer to the following pages for conditions of this permit. 4 of 5
14) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR
ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE
STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES
THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE,
BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL
BE ASSESSED IF OWN CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING
INSPECTIONS,
X
15) A lighting plan and comple d lighting summary shall be submitted to the Mason County Building Department for
approval prior to the final i spection. The lighting summary, attached to the approved set of plans, lists the
maximum allowable light wattage at 5616 watts. Complete the proposed light wattage section listing proposed
lights and wattages ttp gZceed the allowable wattage.
X -
COM2000-00012 Please refer to the following pages for conditions of this permit. 5 of 5
i
CONCRETE MECHANICAL MOBILE HOME
Footings-Setback date by Ribbons
date �, _CVf by 4,l,Z/,!-77Z- Gas Piping date b
! Foundation Walls date by Set Up
date by INSULATION date by
BG/SLAB Insulation Floors Final
date by date by date by
FRAMING Walls FIRE DEPT.
date
PLUMBING by date by date by
Groundwork
Attic OTHER
date b date by
D.W.V. WALLBOARD NAILING
date by date by
Water Line FINAL INSPECTION
date by date 9�i D bye'
date by
5—lv—Dl
/'Z4Eu 5SrE —L v, 7,6 u oz JLI
Z 90 �i��Ad
N -/? -2;i�-///es
IF
T2•��J�. r� . o• � �
d �o o• sip
9ZI Z7 .C)l
l
Building Permit # MASON COUNTY
BUILDING 111 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found: Items Listed below must be corrected to gain code compliance
n C t1V 7Ile'z
F' c S
-S
02
i�- S - S .9l -W •-
S d - �1�L - / ' vvc.
You are hereby notified that t e above corrections shall be made
BEFORE PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing
❑ Make corrections, items will be checked on next inspection
❑ OK to
❑ This is not a complete inspection Department
Date Inspector
moos NnT MOOV T llv--- T A
PERMIT NO.:
MASON COUNTY .� I-7
BUILDING PERMIT APPLICATION
426 W.Cedar/P.O.Box 186,Shelton,WA 98584
Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner —t Contractor Name
Mailing Address Oa Mailing Address
City a Stated Zip Code City State Zip Code
Phone(31,eu ) GU Other Ph.( ) Ph.( Other Ph.(
Lien/Title Holder Contractor Reg. #
Address # ' Expiration
SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic Existing Septic Connect to Sewer
System Name of Sewer System Well X Water System Name of
Water System
PARCEL INFORMATION-12 digit Tax Parcel No.+:J261 / 2 0,009 Fire District
Legal Description
Site Address(Please include street name, street number and city) 00 blvii W 10
Directions to site
Will timber be cut and sold in parcel preparation? (Yes/No)
Is your property within 200' of the following: Body of Water (Name) Saltwater
Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or
Bluffs
TYPE OF JOB New Add Alt Repair Other Use of Building (2 M
Describe Work `ttlo cQ b'' D S
No. of Bedrooms No. of Bathrooms SQUARE FOOTA E-1st Floor 2nd Floor
3rd Floor Loft Basement Deck Other sq. ft.
Garage Attached Detached Carport Attached Detached
MOBILE HOME INFORMATION-Make Model Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price $ Replacement Unit ?(Yes/No)
Installer Name Certification No.
NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF
CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the
information provided is accurate and grants employees of Mason County access to the above described property and structures for review and
inspection of this project. Acknowledgment of such is by signature below:
OWNER AFFIDAVIT-1 certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a
Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance
requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work
conformance therewith. ht6 hange hall be made without first obtaining shall be done in conformance therewith. No changes shall be made without
approval first obtaining approval.
X Date y X
FOR OFFICIAL USE BEYOND THIS POINT
Accepted by Date �/r Submittal Amount Due 11461) Receipt No.t2iL 216 .
r
DEPARTMENTAL. REVIEW APPROVED DENIED'' CONDITION CODES
Building Department kH -d/-=
Occ Grou - Type Constr. A)
Planning Department
Environmental Health Department
Public Works Department
I
Fire Marshal
Valuation $ qq, �75-0 Llet'
FEES
Building Permit Fee t�o2 �Jr— Site Inspection
Plan Review Fee :� kg, / 3e/ UFC Plan Review Fee
ye/Plumbing & Base Fee `7' 7 Public Works Review Fee
Mechanical & Base Fee Other
Wood/Gas/Pellet Stove Fee Other
Violation Fee Pre-Paid at Submittal ( lOQ OO )
T O AL FEES
MASON COUNTY PROJECT SITE INFORMATION
} I Case No.
Name ' ll ,I iN CCEL NUMBER`7 �/ '22'V f Date 1 o U
SHOW THE FOLLOWING ON SITE PLAN Show Direction by indicationg N, S, E, W in relation to the
site plan
Lot Dimensions Fences
Existing Structures Driveways
Structure Setbacks Shorelines
Water Lines Topography
Well Location (including adjacent) Drainage Plan
Names of Streets Easements
Names of Fronting Streets Septic System
DRAW SITE PLAN BELOW Include adjacent properties if on shoreline or within 100 feet of adjacent property line.
adjacent property lined , I Fadjacent property line
I
I I
1
I I
I I
I
I I
I I
I
I I
I I
I
I I
I I
I I
I
I I
I I
I
I I
I I
I
I I
I I
I I
adjacent property line- I I E-adjacent property line
SAMPLE SITE PLAN
adja t property lined _ Fadjacent property line
D 30- rRfsd7rA gel
.gEASo wJ AL. I ti 7�Ic Ho _,- f.
C2fE1G \ I ne t Gr4 u
]I i�ocua
I j PRo PoseD sa ptt c —�I
1 ,
VACAfuT I 1 C ARAaE
I 30' I /i
I(C PM1oPo3CD I
� A6R iCu.LTuJLAL SO � ■■1
I IF-4o'—I \ .gyp•
I I
I �--B O'_'1)
-- I I
I
I � I
I I � c._.eLL
I I
I � /00' I
adjacent property line- ; \; E-adjacent properfy line
TOPOGRAPHY PROFILE(Show a side view of property. Show slopes, cuts and fills. If possible include height and the
degree of slopes. See sample topography profile.)
SAMPLE TOPOGRAPHY PROFILE
d15+Ar.c0- to
ructL-Ye.
&stav'c.c to
S1opa tc¢
�• dii�a..am
4 0 !.
' 7v�
n tur Date
0
I
'pu1� �
I �m wri-�ng �o reC��tes-� a cctnop\/
Ver mit Qxlens)w - k-In e y eoasc-�n cj�- +h 1 S
the �nhnisheG�
Y e model i ng o� the n'eW Sx,� Icy i � 1g
�N
{� 47-0 IZZ-2occ 1
Aft AIRPORT GROCERY,
®Shelton, WAW98584
PACIFICEnmron ental
S E R V I C E S C O M P ANY
P.O. Box 2049 ; 8585 HWY 20, Port Townsend, WA 98368 Phone: (360) 385-4221 Fax: (360) 379-9395
CANOPY QUOTATION
1. CUSTOMER: AIRPORT CHEVRON
2. SITE OF WORK: Hwy 101 Shelton, WA
3. SCOPE OF WORK: CANOPY SIZE: 52' x 72'
BRAND /STYLE:
1) Engineered structural drawings and calculations required for permitting.
2) Structural steel to be prime coated. Pre-welded anchor bolt cages are included.
3) 3/4"electrical conduit and 3" dia. ABS drain pipes in columns.
4) Pre-finished 20 gauge white roof panels and gutter.
5) Pre-finished 42" ACM (alpolic) fascia.
6) Delivered to job site and installed.
BRAND SPECIFIC OPTIONS: Items marked with an( X ) are included in price.
( ) Cladding for columns. ( ) Spanners. or ( )"Pump toppers"
( ) Perimeter down-lighting fixtures. ( ) Illuminated "Red Band" fascia.
EXCLUSIONS:
♦ Electrical connections. ♦ Ceiling light fixtures. ♦ Concrete footings. ♦ Painting of columns.
♦ Signage/ graphics. ♦ P a_, is will be billed separately)
PESCO PROVIDED labor!Ematerial; S 44,750.00,plus sales tax and pe mits.
NOTE: Signed & sealed Engine wins and c i require pre-payment of S 900+ sales tax,
prior to deliyM ;PESCO must pay the Engineer before they will produce them. This cost is included in the
price given above. Please see the Agreement for Drawings and Calculations attached.
READ, ACKNOWLEDGED, AND AGREED TO this day of 9199 _
CUSTOMER ACCEPTANCE: PACIFIC ENVIRONMENTAL
SERVICES COMPANY:
By: ,eS By: ,K
(Authorized signature) PESCO representative
( Printed name/title ) ( Printed name/title )
Date of proposal: September 20, 1999