Loading...
HomeMy WebLinkAboutBLD2008-00927 Addition - BLD Permit / Conditions - 3/12/2009 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2008-00927 _ OWNER: NATHAN HOUSER CONTRACTOR: LICENSE: EXP: RECEIVED: 7/24/2008 SITE ADDRESS: 911 E LAKESHORE DR ALLYN ISSUED: 3/12/2009 PARCEL NUMB EXPIRES: 9/12/2009 LEGAL DESCRIPTION: LAKELAND VILLAGE 7 LOT: 63 PROJECT DESCRIPTION: DIRECTIONS TO SITE: ADDITION OF KCROOM, LAUDRY, PANTRY, BATH, BEDROOM AND HWY 3 TO ALLYN LEFT ON LAKELAND DRIVE LEFT ON LAKESHORE DR -GARAGI�'& Deck TO PROPERTY ON LEFT JUST PAT WESTLAKE WAY ON RIGHT General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 1 Type of Constr.: V-B Type of Use: SF Insp.Area: No. of Bathrooms: 1 Occ. Group: R-3, U-1 Lot Size: Deck: Type of Work: ADD Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:1,081 Garage-Attached 171 Valuation: Building Height: Occ. Status: Prima Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 20.0 Ft. Shoreline: Ft. Water Body: NONE Rear: N 5.0 Ft. Slope: Ft. SEPA?: Unkn Model: Width: Ft. Shoreline Desig.: hWtlA Ilcable Side 1: S Ft. PP Year: Serial No.: Side 2: W Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Lavatories 1 Ventilation Fan 2 Plan Check Fee KS 7/24/2008 $591.34 S12008000 Water Closets (Toilets) 1 Dryer Vent 1 Planning Review Fee KS 7/24/2008 $190.00 S12008000 Clothes Washer 1 EH Plan Review KS 7/24/2008 $40.00 S12008000 Building State Fee RTB 7/30/2008 $4.50 b12008000 Building Permit Fee RTB 7/30/2008 $909.75 612008000 Mechanical Fee RTB 7/30/2008 $25.20 612008000 Mechanical Base Fee RTB 7/30/2008 $26.60 612008000 Plumbing Fee RTB 7/30/2008 $24.30 612008000 Plumbing Base Fee RTB 7/30/2008 $23.10 612008000 Plan Check Fee TW 3/12/2009 $13.65 612009000 Building Permit Fee TW 3/12/2009 $21.00 612009000 Total $1,869.44 BLD2008-00927 Please referto the following pages for conditions of this permit. 1 of 4 s 1 CASE NOTES FOR BLD2008-00927 CONDITIONS FOR BLD2008-00927 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647- 9Q 8 The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X �Vim'_ 2) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 3) All other necessary permits from Mason County, Washington State and/or Federal Agencies that are required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X V\ /'".W - 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Department riop r to any further inspections being performed or approvals granted. X �- 5) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. XL - 6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X k. 7) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X �� 8) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Build ng Department prior to any further inspections being performed or approvals granted. x f r kL1Ge c.n fit , �S—a'I — BLD2008-00927 Please referto the following pages for conditions of this permit. 2 of 4 �) ',,'Nashington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window (Max U-Factor):0.35, Skylight (Max U-Factor):0.58, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab Insulation R-10. Exception: R-30 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the underside of the roof sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation. X 10) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, - inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A" was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X N zs� 11) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 12) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X �� - 13) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 14) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your projec . 1' BLD2008-00927 Please referto the following pages for conditions of this permit. 3 of 4 14 5) AAll changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or r g ulation, must be reviewed and approved by Mason County prior to construction. X V�-- 16) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector III be made prior to requesting additional inspections. X (� 17) All property lines shall be clearly identified at the time of foundation inspection. X y" 18) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason Count o finances and building regulations. X 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have ev nted action from being taken. No more than one extension may be granted. X 20) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and��Ia hin Install metal connectors approved for contact with the new types of pressure treated material. X 21) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure these structures meet the setback conditions listed. X 22) Landings and stairs must meet the same setback conditions as any permitted structure, and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X INS' This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: ��'T G� �r� � � DATE: y y'U� —c BLD2008-00927 Please refer to the following pages for conditions of this permit. 4 Of 4 f 'rill c : W '.20NCRETE MECHANICAL MANUFACTURED HOME p _ c-- �' e+'itti's 1 Setbacks Gas�,P,inDate -g By Ribbons to m oY interior-Date dY t7atW P,yX r1jExterior Date B Exterior Date By r Set- Z Point Load l Isolated footings INSULATION Date Fay BG 1 SLAB INSULATION _ Z Bate By Data BY FIRE DEPARTMENT D Foundation Walls Z Floors Date By Date D" By DECKS FRAMING f�F�jD%O 'C wads Date By Date -L/ By Lma111 Data By L� PROPANE TANKS PLUMBING vault Date By Date `l-•21 - O� By,,(--) OTHER Groundwrork Attic Date By Date By Date By n.w.v DRYWALL Type- Int.Brace Wall pate By W Date r Date By FINAL INSPECTION 0 nCDi Water Line G� Fire Sepe�ration N m Date _ By (/ i7ata�.,d� ByT Date Iv By' �) o0 Pass or Request Inspect. Cl Type,of Insp. Fail Date Date Dane By Comments CID -•t �= o _ . Cn 64 —07 2- a 0 c CID s- /n.9v �jG o v c 4 G w /sir v v►- ,� - 'Chi �S-l/ tipw v _ �/-/•�. zfZ 0 RIName ;RM111, Parcel# 1 2� (q-5�/ �1)6 NO3BLD4 Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. «: ..... . A ::::: ::::::::::la...... rvtA .s: �r� c . ::::::............................. ...r. ... .... ...............................................:, Surface Type Length X Width = Area *All dimensions in feet Buildings X X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X X = Any paved, gravel or packed area per definition above table X = ....: ....;.::.... .. Others X = «I tFe t #aj rft rvii3 s>arsa<i3f.t1?... .§.e0' f X P :::::::::::: ::::. :::._1 .::1 .::.::::.::.:: "2000 O s' care:::#;; .... t t f$»:reatei tf3a :: ................_.......e >::; .. ........:: . Sm.. .Pr.. tQ.r..ratr : : ::a:_ . . :: Total:l:rrt ruiotjsSrfac 'Acea':$uri af::all aiaas::.:::>: .. ...... ....... .:...:::.. ..::..:.:::::::. ...1::.:::. If the Total Impervious Surface Area' LESS THAN 2000 Square F t,please read,acknowledge and sign below. Based Upon the information you have provi e e Ian IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I fiuther acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X �C l7 Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2