Loading...
HomeMy WebLinkAboutBLD2015-00184 SFR - BLD Permit / Conditions - 7/21/2015 (2) Inspection Line(360)427-7262 �0�� CUUN MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar Shelton, WA 98584 `° RESIDENTIAL BUILDING PERMIT BLD2015-00184 OWNER: MARSHALL& SENA SMITH RECEIVED: 3/16/2015 CONTRACTOR: JACK JOHNSON LICENSE: JACKJC1182M1 EXP: 7/21/2016 ISSUED: 7/21/2015 SITE ADDRESS: 300 E ARCHER RIDGE RD ALLYN EXPIRES: 1/21/2016 PARCEL NUMBER: 122203390221 LEGAL DESCRIPTION: PCL 1 OF BLA#06-23 REV I SURVEYS 9/6 & 32/61 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR******FIRE SPINKLER SYSTEM REQUIRED***** WA ST RT 3 N 15.9 MILES, TURN LEFT ONTO E SHERWOOD CREEK RD, TO E BROUGHTON HILL RD, TO E RUSSET RD. General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 5 No. of Stories: 1 Occ. Load: Building:2,417 Garage-Attached 1,059 Valuation: $ 328,731.94 Building Height: Occ. Status: Basement: cobv deck 694 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: W 358.0 Ft. Shoreline: Ft. Water Body: Rear: E 250.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 10.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: S Ft. To C1 _ v.1 b RC K . Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 2 Furnace<100K 1 Plan Check Fee JBN 3/16/2015 $ 1,479.50 S2201500000001 Lavatories 3 Heat Pump 1 Planning Review Fee JBN 3/16/2015 $205.00 S2201500000001 Bath Tubs 2 Ventilation Fan 3 Fire Warden Review JBN 3/16/2015 $73.00 S2201500000001 Showers 1 Woodstove 1 EH Plan Review JBN 3/16/2015 $205.00 S2201500000001 Water Heaters 1 Exhaust Hood 1 Fire Warden Review JBN 3/26/2015 $73.00 S1201500000001 Clothes Washer 1 Dryer Vent 1 Building State Fee RTB 5/1/2015 $4.50 S1201500000001 Kitchen Sink 1 Building Permit Fee RTB 5/1/2015 $2,276.15 S1201500000001 Dishwasher 1 Mechanical Permit Fee RTB 5/1/2015 $ 158.70 S1201500000001 Hosebibs 3 Mechanical Base Fee RTB 5/1/2015 $28.50 S1201500000001 Urinal 2 Plumbing Permit Fee RTB 5/1/2015 $ 128.00 S1201500000001 Plumbing Base Fee RTB 5/1/2015 $24.70 S1201500000001 Total $4,656.05 BLD2015-00184 Please refer to the following pages for conditions of this permit. Page 1 of 7 CASE NOTES FOR BLD2015-00184 CONDITIONS FOR BLD2015-00184 1) PER TITLE 14 MASON COUNTY BUILDING CODE- CHAPTER 14.17, STANDARDS FOR FIRE APPARATUS ACCESS ROADS- 14.17.110: A fire apparatus access road in excess of 14% grade and more than 150'to new residential or commercial structures will require an automatic fire sprinkler system installed. Contact the Mason County Fire Marshal at(360)427-9670, extension 352, for further information. x 2) In accordance with the Standards for Apparatus Access Standards, Mason County Code, Chapter 14.17 Section 110, an automatic fire sprinkler system shall be required and installed in this structure. A separate fire protection permit for the fire suppression system shall be required and submitted for review and approval prior to installation of the required system. Inspection of the installed fire suppression system shall be performed and approved by the Mason County building department/fire marshal office prior tot framing inspection of this structure. X (FL 3) Approved p r ons and setbacks on April 3, 2015 submitted site plan. Setbacks are measured from the furthest projection of the structure. X 4) Applicant acknowledges that site plan is based upon the Lot 1 dimensions on the recorded survey for BLA No. 06-23 approved on June 1, 2006. X 5) All construction and demolition debris must be removed from the site after project completion. Proper construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X Mr 6) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent w to or properties. Silt fencing, straw, or surface matting must be installed and maintained until upland vegetation has become established. X 7) Prior to final approval, all upland areas disturbed or new r d by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 8) Concret c to and wash water must be contained during construction pouring, such that water quality degradation of adjacent waters does not occur. X BLD2015-00184 Please refer to the following pages for conditions of this permit. Page 2 of 7 9) All property lines shall be clearly identified at the time of foundation inspection. X 10) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. All applicable recommendations and specifications shall be applied to the development on this site. Any deviation requires stamped written approval from the registered design professional responsible for the report/assessment, and may require special inspection by same. Structures and/or land modifications (grading, cuts, fills, etc.) required in the geotechnical report/assessment, may require a separate permit. The geotechnical report/assessment shall remain ed to the approved building plans. X 11) All surface water and potential runoff from the proposed development will be controlled on site and shall not adversely affect any adjacent properties, cause sediment deposits, nor increase the velocity flow entering or abutting to any state or county culvert or ditch system or road ay.X / , 12) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approv-1 S'Plan" to ensure these structures are shown and meet the setback conditions listed. X �j,►(,j' 13) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X Q9- 14) Applicant/owner acknowledges that the suitable connection to the North Bay sewer system and fees paid to County Utilities are completed by the time of temporary occupancy of the structure. X 0 0L 15) All other necessary permits from Mason County, Washington State and/or Federal Agencies that are requi f his proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X 16) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-095Z person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 17) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department ipytq any further inspections being performed or approvals granted. X 18) Owner/Agsisponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X BLD2015-00184 Please refer to the following pages for conditions of this permit. Page 3 of 7 19) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal on proved documents will result in failure of required building inspections. 20) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 21) 2012 IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window (Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credits from R406.2 shall be completed as follows: 3b H.P. min. HSPF 8.5, 5a elec. W.H. min. EF 0.93 X 9'10 22) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECCfWSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate" and are available in %or'/2 sheets. The Mason County Permit Center will also have some available. X 2Q__ 23) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. Q X 9/01 BLD2015-00184 Please refer to the following pages for conditions of this permit. Page 4 of 7 24) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000. X Rig: 25) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete /work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 26) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. X 4 UV 27) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charge be collected by the Building Department prior to any further inspections being performed or approvals granted. X 28) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rev o a� tpq. X 29) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 30) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance ore tion, must be reviewed and approved by Mason County prior to construction. X BLD2015-00184 Please refer to the following pages for conditions of this permit. Page 5 of 7 31) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building I spectorrs �sha be made prior to requesting additional inspections. 32) All property lines shall be clearly identified at the time of foundation inspection. X 9. 2:� 33) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County prdinances and building regulations. 34) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have_ �vented action from being taken. No more than one extension may be granted. X �_ 35) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connector a ping. Install metal connectors approved for contact with the new types of pressure treated material. X 36) An inspection performed by the engineer of record, shall be completed on-site prior to the footing pour to verify that earthwork and foundation installation activities comply with the Geotechnical report or assessment recommendations. In addition a final inspection report,prepared by the engineer of record shall be required to verify that erosion control, drainage and final work is completed in accordance to the Geotechnical report or assessment recommendations. Reports shall be submitted to the Mason County Building Dept., 426 W. Cedar St., Shelton, WA 98584, prior to the footing and final inspections and available for inspection. X za: BLD2015-00184 Please refer to the following pages for conditions of this permit. Page 6 of 7 OWNER /BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPC� L TION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Sig at a Date �a c Gt /11 OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) BLD2015-00184 Please refer to the following pages for conditions of this permit. Page 7 of 7 - r to cal� 140 120 . 120 30 FT EASEI#NT login 5 1 r HILL ROAD I r � t 21500 If -y ........._.... . APPRE)XIMATE P OF 40FT BUILDING SETBACKSLOPES EXCEEDING "40 PARCEL ..." 12220-33-90221 -AP- P a VED SEWERS. ARE T® BE MASON COIJI dTY DCD PW STUBBED INTO, LOCAL SITE PLAN REQUIRED TO LBE oN COMMUNITY =S''STEM CHAN ES S BJECTTO APPROVAL 'DP.AINAGE PER BY 1ii Date GEGTECHNICAL " a 'N REPORT AND STORM /ATEP MANAGEME PLAN . . ., SraleS S r . to �� 140 120 •200 .. ISO / 30 FT EASEMENT pill HILL ROAD 41 ,.. T APPRI]XIMATE TOP OF 40FT BUILDING SETBACK SCOPES EXCEE.UING 40 At.uu PARCEL APPROVED12220-33-90221 MASON COUNTY DCD PLAN G SEWERS ARE TO BE' SITE PLAN REQUIRED TO BE ON SI STUBBED INTO, LOCAL CH GES SUBJECT TO APPROVA --COMMUNITY SYSTEM By Date PEP.GEOT N A GE®TECHCHNICAL R 'G REPORT AND N N I STOR%MWATEP MANAGEME PLAN � 2- 2� �33 �O z N SCALE: 1 INCH = 150 FEET 0 75 150 140 120 200 180 160 30 FT EASEMENT r9 659' �— RUSSET RIDGE RWD - Of& 20 FT —.T- To _____ - I00Sir .y MALL READ PROD 4•;Vp" 368 FT IdSIDENCE 210 FT 80 60 si FT 40 APPROXIMATE TOP OF 40FT BUILDING SETBACK" SLOPES EXCEEDING 40' a 200, ED �M PARCEL a 12220-33-90221 SEWERS ARE TO BE STUBBED INTO LOCAL COMMUNITY SYSTEM 102, DRAINAGE PER GEOTECHNICAL REPORT AND STORMWATER MANAGEMENT co m PLAN q PROJECT/ OWNER/ LOCATION: SINGLE FAMILY RESIDENCE ET RIDGE PARCEL 'Z2 20.33_9 xx 1 ALLYN, WASHINGTON ENGINEER, ENVIROTECH ENGINEERING PO BOX 984 BELFAIR, WASHINGTON 98528 360-275-9374 SITE PLAN Z'O . f<'21 /-�� 122205400091 122205400033 122205400032 122205400031 122205400105 122200060010 122205400103 122205400094 122200060010 122203400180 122205400092 122205400095 122205400098 122205400102 122205400104 122205400093 122205400096 122205400097 122205400100 122205400101 122205400099 122205400084 122203300240 FR�SSFT/dIDGE RD 122203300190 122205400083 122203300220 122203400170 122205400082 122203300250 122203300320 122203390221 122205400074 122200060010 E SHERWppD CREEKRD 122295100005 122203390232 122205400073 122203300210 122292200320 122205400073 122295100004 122203390231 122205400072 122295100003 122203390233 122203300290 122203300211 122295100001 122292200280 122203390232 - 122292200390 122307600041 E BROUGHTON HIL'VR� 122292100270 122292200310 -22 RI 29, jt 122292200330 122292290341 122290060010 ,y 122301100010 122292290344 122292290342 122301100060 122292290343 122301190090 122301190090 122292222222 122292290351 122292290368 o rce: E-sri. DigitalGlobe. ��o€�ye'9 cube�`6 •-D ,�USGS',°FQ€X5 122301190050 122292290367 et apping erogrid. I�N � ' s i stoPo. a d the GIS ser o unity N 1 inch = 200 feet W+- 1 E 1 inch = 0 miles S '00, BUILDING Name $� `rf� Parcel# 1,X Z 2O -- 33 `G`O:(2�O BLD#_ Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet(page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area 'All dimensions in feet Buildings X = O X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X s 2-5 _ c+ X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved,gravel or packed area per definition above table X = Patios/Walks X = &0 X = Any paved,gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) Aj 770 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement o ch is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowled t t information provided is accurate and employees of Mason County are granted access to the above- described prope for ev e d inspection as may be required. X Owner/Agent/Contractor(circle one)Date: I 1 If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. RECEIVED Page 1 of 2 MAR 16 2015 426 W. CEDAR ST. Name .5,o&,-r/ Parcel# / Z- ,Zo--33 r 02 g v BLD# RO 01 Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: hi!p//www.co.mason.wa—us/code/comm i ssioners/index_htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. ;These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout' PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850,Shelton WA 98584 Physical: 415 N 6th St,Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of suc by Signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge tha e f ion vided is accurate and employees of Mason County are granted access to the above- described property for r ie tion as may be required. X Owner/Agent/Contractor(circle one)Date: l Page 2of2 RECEIVED MAR 16 2015 428 W rFnAM BUILDING ♦� .c_ MASON COUNTY PERMIT NO.-kb P%O 5 - DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING a PLANNING•FIRE MARSHAL DD' WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg.III,426 West Cedar Street (360)275-4467 Belfair ext.352 PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 RECTEIVED BUILDING PERMIT APPLICATION 46A •- �`%6q 015 OWNER INFORMATION: CONTRACTOR INFORMA O �'r �j' 26 l'V, C E D R ST. NAME: 4/-S� ft �� Se � S�f NAME: a l/IG MAILING ADDRESS: /5'01/ 4�_ ST,k,t le6 MAILING ADj2RESS: _ CITY: 00,4g,", STATE: 4JA ZIP: 3;L fr CITY: STATE: IP: 'L PHONL95 3 /3 CELL:360-5�lrf-97-00 PHON : �-CJ`K�ELL IQJ EMAIL: EMAIL : I laxG. 66M L&I REG# S 19LI&I EXP._I_/2_/ PARCEL INFORMATION: cf p2 2 I PARCEL NUMBER(12 DIGIT NUMBER) �2'22O �✓�"` FIRE DISTRICT LEGAL DESCRIPTION(ABBREVIATED): IJC I- a�f3L O �3(j2)�11' l fl7T2ia S�l�V y 3 z 6/ SITE ADDRESS F, Zqr 2 Rd, CITY A LY. DIRE-CTTIONS TO SITE A }LESS E S r �✓ E &vf L'.'e P /? �r J� IS PROPERTY WITH&200 FT: SALTWATER❑ LAKE❑ RIVERICREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF ❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES[ NO❑ TYPE OF JOB: NEW V ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) R�S 11�p�✓C IS USE: PRIMARY SEASONAL NUMBER OF BEDROOMS_ NUMBER OF BATHROOMS_ DESCJUBEWQRK �v fjk ./ rrJ.e .✓ di;/C S rY� t01•��� '�/res+c C �Gy�t ..✓� SQUARE FO TAG . 1 ST FLOOR.Z 1 7 sq. ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. G�s DECK sq.ft. COVERED DECK_ q.ft.STORAGE sq.ft. OTHER sq.ft. GARAGE f T sq.ft. ATTACHED❑ Dt r r+CHED❑ CARPORT sq.ft. ATTACHED❑ DETACHED❑ MANUFACTUR ME INFOR *4 COPIES H LOOR PLAN-,--' MAKE MODEL YEAR LENGTH B MS BA SERIAL NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided i rate and grants employees of Mason County access to the above described property and structure(s)for review and inspectio .T is p tion becomes null&void if work or authorized construction is not commenced within 180 days or if constructio rk i s for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INAC TY IS P IT APPLICATION OF 180 DAYS WILL IN1D1�ATj THE APPLICATION. X Sig of Ap nt Date I —f X A OWNER/REPRESENTATIVE/CONTRACTOR Print Name (CIRCLE TO INDICATE) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT Telm PLANNING DEPARTMENT BUILDING 61 p 5� oot8`� MASON COUNTY PERMIT NO. DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg.III,426 West Cedar Street (360)275-4467 Belfair ext.352 PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 RECEIVED PLUMBING & MECHANICAL PERMIT APPLICATION MAR 16 2015 OWNER INFORMATION: ,f CONTRACTOR INFORMATION: 426 W. CEDAR ST. NAME: NAME: MAILING ADDRESS: IS-2,71 ,ec 5rr/ZV «'G MAILING ADDRESS: CITY: 73e/Air STATE: i--)A ZIP:9'2 CITY: STATE: ZIP: PHONE:15`3 :(�^ jS`5'� CELL: 140 -.i�j� 97,nr-- PHONE: CELL: EMAIL: EMAIL : L&I REG# EXP. PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER): LEGAL DESCRIPTION(ABBREVLATED): ILL 7 CP'C ; e&-";U3(10A _ 1 F77-�/0 549V4 y SITE ADDRESS: 0 AJ . CITY_: le A/ DIRECTIONS TO SITE ADDRESS: L:% 5l'' T7 �-5 e i,��od C'r e e K . • .,A/ .F.' 3rciT to_,v dl- .7L ' u sS r7' Z: e TYPE OF JOB NEW ✓ ADD ALT REPAIR OTHER USE OF BUILDING F&51'j'F Vice LOCATION OF FIXTURES&D4TS— I ST FLOOR ,/ 2ND FLOOR BASEMENT GARAGE—OTHER— PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump Toilets 2 Typg of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs X Heatpump _ Showers / Spot Vent Fan Water Heater / Propane Tank Clothes Washer / Gas Outlets Kitchen Sinks / Wood/Gas/Pellet Stove Dishwasher / Kitchen Exhaust Hood Hosebibs ,3 Dryer Vent Other L<RIsiAL 2 Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed.1 have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants oyees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application co s @da void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a od 18 .PR F OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTMTY OF THIS PERMIT APPLICA O OF WILL INVALIDATE THE APPLICATION. X 1� Sign of Applica t Date X Owner/Owners Representative/Contractor Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT / PLANNING DEPARTMENT �►� .cam' MASON COUNTY PERMIT NO. bbb RO1 ✓ " _ DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL aD f WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg.III,426 West Cedar Street (360)275-4467 Belfair ext.352 PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 n �I ---- RECEIVED BUILDING PERMIT APPLICATION ',AI �t &A 015 OWNER INFORMATION: CONTRACT'OR INFOR 1MA O NAME: N4/'��ft �/ �/ St°,v S 1/y � NAME: tJ a �G �O 1'I 1nr-I&I- 4 2 6 vv CEDAR S T. MAILING ADDRESS: /:5'o y/ Sr!7-f lee, MAILING_ADDRESS-. CITY: �°/� i r STATE: �r//1 Z_IP: y;Z rf CITY: STATE: IP: Z PHONE:.Z:5'3-,Z -%3 Y�CELL:360-5a'7-Yroe► PHONE: ^5`JU�ELL (gyp EMAIL: EMAIL L&I REG# EXP.Z/74 PARCEL INFORMATION: pa y-7-zo I S PARCEL NUMBER(12 DIGIT NUMBER) %�'Z� �✓ " FIRE DISTRICT LEGAL DESCRIPTION(ABBREVIATED): CL 5_e9V 3V G/ SITE ADDRESS 'OF, jzq 5 '0 CITY A I-L DIRECTIONS TO SITE ADDRESS _I=- S r` T' _ - e�+J?. C:^e e %? } 11 0'J A A-, 4— ' �-o. to `rn -. ?w 5S e t- l e rz IS PROPERTY WITA 200 FT: SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF ❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES[✓7 NO❑ TYPE OF JOB: NEW V ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) R e S lade—IC C IS USE: PRIMARY SEASONAL NUMBER OF BEDROOM NUMBER OF BATHROOMS DE SC E WOr/�'tr S X/z •,/ 4+it!'� S/o YY, fd1 n.�� 'fir4y2 C' rd"e i,✓, C PQ �p p SQUARE FO TAG : I ST FLOOR;Z /7 sq. ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq. ft. COVERED DECK_(psq.ft.STORAGE sq.ft. OTHER sq.ft. GARAGE,Jt�sq.ft. ATTACHED❑ Dt t .CHED❑ CARPORT sq.ft. ATTACHED❑ DETACHED❑ MANUFACTUR ME INFOR *4 COPIES OOR PL MAKE MODEL YEAR LENGTH B MS BA SERIAL NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided i ccurate and grants employees of Mason County access to the above described property and structure(s)for review and inspectim .T is p tion becomes null&void if work or authorized construction is not commenced within 180 days or if constructio rk i s d for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INAC TY T IS P IT APPLICATION OF 180 DAYS WILL IN), IDA E THE APPLICATION. X '7 I Lo lq Sig tur of Ap icant Date X OWNER/REPRESENTATIVE/CONTRACTOR Print Name (CIRCLE TO INDICATE) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT R1j WhINIfAL CAN aOIB'� MASON COUNTY PERMIT NO. p 5- DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING v FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg.III,426 West Cedar Street (360)275-4467 Belfair ext.352 ISM PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 RECEIVED PLUMBING & MECHANICAL PERMIT APPLICATION MAR 16 2015 OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: fi1&r'3 g/ �S'e,V-t. S��r r' NAME: 426 W. CEDAR S T. MAILING ADDRESS: !S�-'7/ .g- Sr xt. toG MAILING ADDRESS: CITY: 13r/1-ct i'r STATE: t.-JA ZIP:95S CITY: STATE: ZIP: PHONE:;ZS CELL: I&C -- .:r-y;Aco PHONE: CELL: EMAIL: EMAIL : L&I REG# EN P. PARCEL INFORMATION: qD o_a l PARCEL NUMBER(12 DIGIT NUMBER): j� - LEGAL DESCRIPTION(ABBREmTED): lPrL 54XV4 SITE ADDRESS: —', W,tsS,T' P - CITY: A/,I YA1 DIRECTIONS TO SITE ADDRESS: R-. S'r. i<'t 3 7 G, _54&r .�nc)d C e e k 9J. �l TYPE OF JOB NEW ✓ ADD ALT REPAIR OTHER USE OF BUILDING Re5r'dPF4,ce LOCATION OF FIXTURES/UNITS— 1ST FLOOR ,/ 2ND FLOOR BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump V Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs :G Heatpump Showers / Spot Vent Fan Water Heater / Propane Tank Clothes Washer I Gas Outlets Kitchen Sinks / Wood/Gas/Pellet Stove Dishwasher / Kitchen Exhaust Hood Hosebibs :3 Dryer Vent Other URJW1 L Z Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants loyees of Mason County access to the above described property and structure(s)for review and inspection.This permittapplication b co es nu void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a p 'od f 18 da .PR F OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICA O OF 80 WILL INVALIDATE THE APPLICATION. x I 1Lo ll C) Sign i of Applica t Date X Owner/Owners Representative/Contractor Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT �o� wlx Ev�,v%rotech ev�.g�v►.eer�v�.g QL� �- cieotechvt,LoaL o EvwLrowvuevLtaL°DraL"Oe°rzoadwaU March 11, 2015 RECEIVED MAR 16 2015 Jack Johnson Construction, Inc. PO Box 1119 426 W. CEDAR ST. Belfair, Washington 98528 RE: Geotechnical Report Addendum 41 for Knutsen Tracts Single Family Residences,Parcel 12220-33-00220,Mason County,Washington Dear Mr.Johnson, Envirotech Engineering (Envirotech) has completed this geotechnical report addendum for the above referenced project. The original report, dated June 12, 2008, was prepared by Envirotech (Project#0857). The site was revisited by Michael Staten with Envirotech on March 3, 2015 in order to evaluate the proposed project and verify the absence of new geotechnical hazards since our initial site visit in 2008. We conclude that topographic and geologic conditions were unchanged. Furthermore, we conclude that the conclusions and recommendations established in the original geotechnical report remain applicable to this project. Envirotech is pleased to submit this addendum. Please contact Michael Staten at 360-275-9374 if you have any questions,comments,or require additional information. Best Regards, Envirotech Engineering C LYDE S `GAP O WASy�M T9)� 43045 �cv4 CAST-, �sS�QNAt 6�G` Michael Staten,P.E. Geotechnical Engineer Envirotech Engineering Geotechnical Report Addendum#I PO Box 984 Page 1 of 1 Knudsen Tracts Single Family Residences Belfair,Washington 98528 Parcel 12220-33-00220 Ph.360-275-9374 March 11,2015 ArcIMS Viewer Page 1 of 2 t Lake Anderson LU i `► GNAryyEC 4� uj -cs LU r 4k� H � F�R GFR�. E NORTH BAY PL NHr�Rp r http://mapmason.co.mason.wa.us/website/mason/MapFrame.htm 3/26/2015 I 9 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT FIRE MARSHAL 8 Mason County Bldg. III, 426 West Cedar Street PO Box 186, Shelton, WA 98584 www.co.masonma.us Shelton (360)427-9670 Belfair(360)275-4467 Eima (360)482-5269 March 30,2015 Marshall&Sena Smith 15071 E State Route 106 Belfair WA 98528 Mason County Building Permit Number:BLD2015-00184 Parcel number: 12220-33-00220 Dear Mr.&Mrs. Smith Mason County Building Inspector Larry Kelly conducted an inspection of the parcel referenced above on March 27,2015,in order to verify compliance to Mason County Building Code,Chapter 14.17, Standards for Fire Apparatus Access Roads. A copy of the access standards and addressing guidelines referenced in the standards are enclosed. PLAN REVIEW REQUIREMENT COMMENTS: 1. During the inspection the inspector found that the access road does not comply with Section 14.17.110 that reads as follows: "A fire apparatus access road which is newly constructed or existing, and which is in excess of 14%grade, and which is greater than 150-ft from a primary access point intersecting with a County or State road right of way, to new residential or commercial construction will require an automatic fire sprinkler to be installed" As a result a condition concerning the required fire sprinkler system has been added to the building permit referenced above. To comply a separate fire protection permit shall be required for the fire-sprinkler system. Submit fire- sprinkler permits to the Mason County Building Dept./Fire Marshal office where the building permit was submitted. After the fire sprinkler permit is issued you or your contractor will need to request an inspection prior to the framing inspection of the project. The inspector will verify that the fire-sprinkler system is installed in accordance with the approved plans. If you have questions please contact the Mason County Permit Center office at(360)427-9670 ext.284 Sincerely, Genie McFarland Mason County Department of Community Development CC: Jack Johnson,P.O.Box 1119,Belfair,Wa 98528 Encl.: Title 14 Mason County Building Code,Chapter 14.17 Standards for Fire Apparatus Access Roads Address Posting Requirements Guidelines for Private Road Signing t- IKt IVi'ARSHAL ACCESS & GRADE INSPECTION BLD �� y Ov 1IYLI r 2�d _4DDRES �.�'.'�. ao. C` ��f.SS�-� INSPECTOR: DATE OF INSPECTION: FIRE SPRINKLER REQUIRED? (circle) NO CE) IF fire sprinkler required, was notification letter mailed`? DATE MAILED: DRIVEWAY ACCESS ()() need post at access of driveway with reflective address numbers Length: Width: Surface: Size of turn-around: Condition of shoulders: Vertical clearance: GRADE OF DRIVEWAY %, OF ROAD % ROAD ACCESS Length: Width: Surface: Condition of Shoulders: Vertical clearance: ( ) BURN PERMIT REQUIRED FOR LAND CLEARING FIRE. �) LOT INSIDE UGA—NO OUTDOOR BURNING PERMITTED. LOT TOO SMALL FOR: BURN PERMITS 4 X 4 FIRES 2 X 3 FIRES PASSED ( ) FAILED C ON HOLD ( ) REMARKS: � � n l r�+��l , "Q�` ,�[��Gxi.��y b� �/'bKG,h�a� yam,(,1 60(✓L Mason County Map Output Page Page 1 of 1 Mason County Map �k r r m g Lake erson { t CyA1,4, Q f4� m m r J �4R�y%F R4SSET R'pCFR ' O E SHERyyppp CREEK Rp E NORTH BAY PL Rp / 0 51 A DISCLAIMER AND LIMITATION OF LIABILITY: The data used to make this map have been tested for accuracy,and every effort has been made to ensure that these data are timely,accurate and reliable.However,Mason County LEGEND makes no guarantee or warranty to its accuracy as to labeling,dimensions,or placement or location of any map features contained herein.The boundaries depicted by these data are Roads Pedwal Land, approximate,and are not necessarily accurate to surveying or engineering standards,and are intended for informational purposes only.Mason County does not assume any legal liability Z'\/Hrgrwraya City of Shelton or responsibility arising from the use of this map in a manner not intended by Mason County. �r RrvdrS d Strvaens In no event shall Mason County be liable for direct,indirect,incidental,consequential, t t G�°x'ty E{�ura70ry{pNR) special,or tort damages of any kind,including,but not limited to,loss of anticipated profits parcels Comry,ssronor Ctstncts or benefits arising from use of or reliance on the information contained herein it Sectons * Ldke5 ©2009-Mason County GIS Tewrtshgrs JJO Fuget Sound$Major Lakes 100 W.Public Works Dr Shelton,WA 98584 http://mapmason.co.mason.wa.us/serviet/com.esri.esrimap.Esrimap?ServiceName=amason... 3/26/2015 2220 �3 - oo -2 r� � IRE MARSHAL SCALE- 1 INCH = 60 FEET 110 FT 35 FT 0 15 30 60 ACCESS ROAD M 49 FT �ji ) 200 PROPOSED _ RESIDENC o 0 PARCEL 12220-33-00240 co 160 PARCEL ! m I 12220-33-002501 V ik- 1 PARCEL 221' 1 12220-33-00220 DRAINAGE PER GE❑TECHNICAL REPORT 1 AND STORMWA ER MANAGEMENT P AN 1 VAX 1 APPROXIMATE T11P OF SLOPES 1 rll��EXCEEDINC 407. 1 1 3 A PARCEL 12220-33-00210 �w a ' w 40FT BUILDING S TBACK & VEGETATION BUFFER 'FROM TOP OF SLOPES EXCEEDI 40% PROJECT/ OWNER/ L CATION SINGLE FAMI Y RESIDENCE GE❑TECHNICAL REPORT E RUSSET RIDGE ROAD PARCEL 12220 33 00220 PTO ALLYN, WASHINGTON Sep— Zv,4 yj<o�tir ENGINEER ENVIROTE CH ENGINEERING 984 74INGTON 985 28 36 0753 Ser t Sidz %Q ' MAR 16 20 5 SITE PLAN 426 W. CEDAR ST. FIRE , , COU MARSHAL MASON COUNTY PERMIT NO. 6Lb _ DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL 00I y WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg.III,426 West Cedar Street (360)275-4467 Belfair ext.352 t" PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 E C E I V E D BUILDING PERMIT APPLICATION L:6, 015 OWNER INFORMATION: CONTRACTOR INFORMA O �?6 �V,V CEDAR ST. NAME: Alg-r�s�/�_ �� S�,i1 Sim���/� NAME: �a �01'I V1S01'%_ MAILING ADDRESS: /:'d I/ ST:tel: /e'G MAILING AD SS: CITY: /?�'/F-',Pi' STATE: ZdA Z_IR :S Zrt CITY: STATE: IP:_ Z PHONB:Z5 3-.Z_6b i5 yf CELL:;360-5JY{,9700 PHON EMAIL: EMAIL: G G. L&I REG# S Z l EXP._ /JJZ PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER) %�'��® "�✓ �' a FIRE DISTRICT LEGAL DESCRIPTION(ABBREVIATED): CL of JU ' gef6-,43(tZ Ar 7,1 iv -SWA6r SITE ADDRESS OL P<q S 'C, `f RX. CITY A L/- DIRECTIONS TO SITE R t� SS �' r �` S �r��k �'s e l %? /?r f- ZZ�u / 'V -7'' Z-77 /Z'1sSe't` IS PROPERTY WITH&200 FT: SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES 2'NO❑ TYPE OF JOB: NEW V ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) Re-3/de—lee IS USE: PRIMARY V SEASONAL NUMBER OF BEDROOMS_ NUMBER OF BATHROOMS_ DESC E WO "�� �.�:'/�� dt1 z ..✓ �:v e s i r y ���n.:0 •�s.���. �L�� �� SQUARE FO TAG : 1 ST FLOOR.2 1 sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq. ft. COVERED DECK_(psq.ft.STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. ATTACHED❑ DtiixCHED❑ CARPORT sq.ft. ATTACHED❑ DETACHED❑ MANUFACT ME INFOR *4 COPIES OOR PL MAKE MODEL YEAR LENGTH B MS BATH SERIAL NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided i ccurate and grants employees of Mason County access to the above described property and structure(s)for review and inspectio .T is p tion becomes null&void if work or authorized construction is not commenced within 180 days or if constructio w rk i s de for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INAC TY T IS P IT APPLICATION OF 180 DAYS WILL INV,�I'IDA[E THE APPLICATION. x '�ICII�11Gi Sig atur of Ap lea <•nt Date �I � x OWNER/REPRESENTATIVE/CONTRACTOR Print Name (CIRCLE TO INDICATE) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIJ EM& AL MASON COUNTY PERMIT NO. D&5- _ DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING-PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg.III,426 West Cedar Street (360)275-4467 Belfair ext.352 Im PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 RECEIVED PLUMBING & MECHANICAL PERMIT APPLICATION MAR 16 2015 OWNER INFORMATION: CONTRACTOR INFORMATION: 426 W. C E D R ST. NAME: melr'i ha/ el, j"-I r' NAME: MAILING ADDRESS: 16;--1`7l r- Sr Xt:' «16, MAILING ADDRESS.- CITY:P CIA*i'w STATE: 4JA( ZIP: CITY: STATE: ZIP: PHONE:;ZS-3-:lam•­i!`'VY CELL: 6,0 PHONE: CELL. EMAIL: EMAIL -. L&I REG# EXP. PARCEL INFORMATION: 9'v2 Z PARCEL NUMBER(12 DIGIT NUMBER): LEGAL DESCRIPTION(ABBREVIATED): i:CCi 7 of`f3 SITE ADDRESS: W-1-gs v t CITY: AIZ Al DIRECTIONS TO SITE ADDRESS: E _5'r, J<1 3 : -5Lr c'd C lee& 9- , t K;_kA't TYPE OF JOB NEW tl ADD ALT REPAIR OTHER USE OF BUILDING 9&51',PFA'1-P LOCATION OF FIXTURES/UNITS—1 ST FLOOR ,/ 2ND FLOOR BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Tvpe of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat PumpZ Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heatpump Showers / Spot Vent Fan Water Heater / Propane Tank Clothes Washer / Gas Outlets Kitchen Sinks I Wood/Gas/Pellet Stove Dishwasher / Kitchen Exhaust Hood Hosebibs :3 Dryer Vent Other aRjw� L .'Z Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.1 declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants qmployees.of Mason County access to the above described property and structure(s)for review and inspection.This permitlapplication b co es nu void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a p "od f 18 da .PR F OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICA 10 OF 80 WILL INVALIDATE THE APPLICATION. x � 1�ll Sign51 , f Applica t (� Date X �I`C W � Owner/Owners Representative/Contractor Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT n oN S7grF MASON COUNTY P� A o N DEPARTMENT OF COMMUNITY DEVELOPMENT o- NT Planning Division T Y 426 W Cedar St, Shelton, WA 98584 .�° (360)427-9670 1864 NOTIFICATION OF INCOMPLETE APPLICATION April 03, 2015 MARSHALL & SENA SMITH 15071 E ST RT 106 BELFAIR WA 98528 Parcel No.: 122203300220 Project Description: NEW SFR******FIRE SPINKLER SYSTEM REQUIRED***** Dear Applicant: You have submitted a permit application (case no. BLD2015-00184) for proposed construction or development in the county. Upon review of your application, I have determined that the contents of the application are incomplete or do not provide enough detail for review. Therefore, review of your application will not proceed until the necessary information is provided (see the comment section of this letter for details.) Once the information is submitted and the application is complete, I will continue to process your application accordingly. If the additional information is not provided to the County within 180 days of this request, the application shall expire and no further action on the proposed development shall take place. Please contact me at (360) 427-9670, ext. 365 if you have questions. Sincerely, Allan Borden Land Use Planner Mason County Planning Department 4/3/2015 Page 1 of 2 BLD2015-00184 NOTIFICATION OF INCOMPLETE APPLICATION 4/3/2015 Case No.: BLD2015-00184 Comments: The site plan for this building permit shows a smaller residence [51' by 74'] than the detailed plan sheets (66 ft. deep by 78 ft. wide] for the proposed residence. The width of the lot (east to west) is 111 ft. and may not allow a 66 feet deep house with a driveway facing to the west, when you account for a 30 ft. wide access easement (Russet Ridge) to the property and a 40 ft. setback from the slope. Please prepare a new site plan with setbacks from the property lines, access easement, and top of slope. Is a lot combination with the property to the east needed to provide adequate building area as a result of this larger home footprint and needed setbacks ? 4/3/2015 Page 2 of 2 BLD2015-00184 122205400037 122205400036 122205400034 , QJ E C 122205400033 m� HgNH�`OR 122205400032 ` 122205400091 122200060010 �* 122200060010 122205400094 f 1 205 092 122205400095 122205400096 122205400093 122205400097 122205400098 122205400084 E RUSSET RipGFRp 122203300240 122205400083 122203300220 122203300250 122292200320 122203300210 122203390221 122205400082 122205400074 122205400073 122205400073. Source. Esr Dig t !"Ice e,GaoE=,ye i-cubed. 1222033002�erog:rid, IG , I�P, s isetopo,and t e SIS User Commu ity Page 1 of 2 Allan Borden - RE: Allyn UGA Lot Combos? From: Michael MacSems To: Johnson, Jack Date: 3/26/2015 11:49 AM Subject: RE: Allyn UGA Lot Combos? CC: Adkins, Barbara; Borden, Allan Attachments: 20150326111313328.pdf Jack, I've talked to Genie and Barbara about this. There might be a misunderstanding. Barbara and I are thinking that you probably can develop this lot as you have proposed, with the aid of a series of administrative variances to reduce your front yard setbacks to as little as 10' and your side yard setback to 5'. It seems like due to the lot constraints the variance could be approved, and Barbara would prefer to go that way, rather than grant the exception to 17.03.030.0 if the lot actually is buildable with setback variances. How does that sound? For the record, I'm am only involved in this because you called me with the lot combination question. Allan Borden will the planner that will actually see this through. Thanks, Michael >>> "Jack Johnson" <jjc@hcc.net> 3/26/2015 10:05 AM >>> Thanks Michael Sena and Marsall Smith (my daughter and son-in-law purchase all the property from me. Currently they have a building permit application in on parcel 12220-33-00220. Because of the steep slopes setback(Per Michael Staten, Geo-tech), set back requirements from the road way easement North and West property lines the house they want to build cannot be sited.Therefore it does fall under the exception allowed under 17.03.030 C as I see it. Genie in the MC permit center is the one that has denied our site plan application. This is how we would like to address her concerns. Let me know if you concur? Thanks, Jack Johnson (360)731-7101 jjc@hctc.com file:///C:/Users/ahb/AppData/Local/Temp/XPgrpwise/5513F240Masonmail... 3/26/2015 Page 2 of 2 From: Michael Macsems [mailto:mms@co.mason.wa.us] Sent: Wednesday, March 25, 2015 4:10 PM To:Jack Johnson Subject:Allyn UGA Lot Combos? Jack, 1 would have called you back but the last two digits of your phone number got cut off. Regarding your question about combining lots is the Allyn UGA,there is a problem with that. Section 17.03.030.0 of the MC Development Regulations restricts the combination of lots in the Belfair and Allyn UGAs if the resulting parcel is greater than 8,000 sq ft. Almost no lots, including the lots created in the original Town of Allyn plat can meet this standard. Here is a link to the Dev Regs, see page 16. http://www.co.mason.wa.us/code/Communitv Dev/dev regs—june 2009.pdf Michael file:///C:/Users/ahb/AppData/LocaUTemp/XPgrpwise/5513F240Masomnail... 3/26/2015 20 3 3 -- 00 20 OWA4-) SCALE- 1 INCH = 60 FEET 110 FT 35 FT 0 is 0 60 ACCESS ROAD � 40' Jo ,,'' C49 FT 2C0 PROPOSED RESIDENCE — - o N _ PARCEL 12220-33-00240 � M 1Qo 160 PARCEL 12220-33-00250 I � 14u PARCEL 1 12220-33-00220 221' DRAINAGE PER GE❑TECHNICAL REPORT AND STORMWAl ER MANAGEMENT P AN APPR❑XIM TE T11P OF SLOPES j EXCEEDIN 40% 1 3 o PARCEL OK 12220-33-00210 �w w 40FT BUILDING SETBACK & VEGETATION BUFFER FROM TOP OF SL❑PES EXCEEDI 407 PROJECT/ OWNER/ L CATION- SINGLE FAMILY RESIDENCE �� /q�A, ��� K'/ GE❑TECHNICAL REPORT ` vv11 E RUSSET RIDGE ROAD PARCEL 12220 33 00220 ° ALLYN, WASHINGTON ENGINEER gENVIROTECH ENGINEERING I) BOX 84 R E C E I`� BELFAIR 9 WASHINGTON 98528 t {L Pe r : '20 360-275-9374 MAR 16 2015 SITE PLAN 426 W. CEDAR ST. Page 1 of 2 Rich Balderston - RE: BLD2O15-00184 From: "Tom Herstad Building Design" <herstaddesign(abwavecable.com> To: "'Rich Balderston"' <RBalderston@co.mason.wa.us> Date: 5/1/2015 11:44 AM Subject: RE: BLD2015-00184 Hi Rich, Both of the garage headers would be 4"x12" beams. Mike Fortman Tom Herstad Building Design, Inc. 296 Tremont St, Port Orchard, WA 98366 360-876-6893 herstaddesign@wavecable.com From: Rich Balderston [mai Ito:RBalderston @co.mason.wa.us] Sent: Friday, May 01, 2015 10:13 AM To: Design, Tom Herstad Building Subject: RE: BLD2015-00184 Tom, I don't see the size of the O.H. garage door headers, can you provide me with those sizes and with your permission I can add them to the plans. Thanks Rich >>> "Tom Herstad Building Design" <herstaddesign@wavecable.com> 4/30/2015 3:09 PM >>> Hi Rich, 1. Yes we want to use the rebar spacing per IRC 404.1.1(2) 2. Attached you will find the completed detail (did not print correctly on plans) 3. The owners just want a tall crawlspace no plans for future basement at this time file:///C:/Users/rbalderston/AppData/Local/Temp/XPgrpwise/55436723Masonmai11001693... 5/1/2015 Page 2 of 2 Let me know if you have any other questions Mike Fortman Tom Herstad Building Design, Inc. 296 Tremont St, Port Orchard, WA 98366 360-876-6893 herstaddesign@wavecable.com From: Rich Balderston [mailto:RBalderston@co.mason.wa.usl Sent: Thursday, April 30, 2015 2:38 PM To: jjc(bhctc.com; herstaddesignCalwavecable.com Subject: BLD2015-00184 Jack and Tom, I'm doing the building plan review of the Smith SFR. The plans submitted show a tall basement wall that does not meet the requirements of IRC table R404.1.1(2). I have attached the table for your review, the plans show the wall being up to 9' tall so it would need to be constructed as per the 94" portion of the table and it appears to be around 8' of unbalanced backfill. If you chose to construct the wall as per the table just let me know and I will attach the table to your plans, the other option is to provide an engineered design stamped and signed by a Washington State licensed Engineer, this design should include plans and calculations. Page 2 of the plans has a detail for a Simpson stand off base. The detail doesn't appear to be complete or maybe I'm just not understanding what this detail is telling me. Please provide some clarification on this detail. The plans show a portion of the underfloor space as an unfinished basement. Unfinished basements are considered the same as a tall crawl space, if at some time the owners want to convert the unfinished basement to finished space it will become a habitable basement and will be required to have at least one window that meets all egress requirements. I'm just giving you and the owners a heads up in case that may be a consideration. Please reference your building permit number, BLD2015-00184, on anything you submit. Thanks Rich No virus found in this message. Checked by AVG - www.avq.com Version: 2015.0.5863/Virus Database:4339/9664 - Release Date: 04/30/15 No virus found in this message. Checked by AVG -www.avq.com Version: 2015.0.5863/Virus Database:4339/9673 - Release Date: 05/01/15 file:///C:/Users/rbalderston/AppData/Local/Temp/XPgrpwise/55436723Masonmai11001693... 5/1/2015 EvLVt,roteC,k G-KOL'MerL�0 , 6L 0 20 ) !�- 60 ceotechvdoal.a enviwcvLKLtKtat o Drai"e3e o Roadway March 11,2015 RECEIVED PLANNMG MAR 16 2015 Jack Johnson Construction,Inc. 426 W. CEDAR S T. PO Box 1119 Belfair, Washington 98528 RE: Geotechnical Report Addendum#1 for Knutsen Tracts Single Family Residences,Parcel 12220-33-00220,Mason County,Washington Dear Mr.Johnson, Envirotech Engineering (Envirotech) has completed this geotechnical report addendum for the above referenced project. The original report, dated June 12, 2008, was prepared by Envirotech (Project#0857). The site was revisited by Michael Staten with Envirotech on March 3, 2015 in order to evaluate the proposed project and verify the absence of new geotechnical hazards since our initial site visit in 2008.We conclude that topographic and geologic conditions were unchanged. Furthermore, we conclude that the conclusions and recommendations established in the original geotechnical report remain applicable to this project. Envirotech is pleased to submit this addendum. Please contact Michael Staten at 360-275-9374 if you have any questions,comments,or require additional information. Best Regards, Envirotech Engineering Any C LYDE S VYASq TI p �A FGISTtiR� �sS�DNAL ECG` Michael Staten,P.E. Geotechnical Engineer Envirotech Engineering Geotechnical Report Addendum#I PO Box 984 Page 1 of 1 Knudsen Tracts Single Family Residences Belfair,Washington 98528 Parcel 12220-33-00220 Ph.360-275-9374 March 11,2015 Page 2 of 2 Date: Thu, 16 Jul 2015 15:04:34-0700 From: RebeccaH@co.mason.wa.us To: bwolfmom@msn.com Subject: Parcel 122203390221 Hello Barbara, There is a geotech report from 2007 that was prepared for the grading and development on the parcel below yours. It is attached. However, the grading permit was never issued. And Jack Johnson had canceled his subdivision plans. It's possible that the current owner, who is just developing for one home (I believe), is not triggering a grading permit. Since he used the geotechnical report from 2007 for the current building permit application, he will be held to the recommendations made within that report, and he will be required to submit an inspection report per the following permit condition: "An inspection performed by the engineer of record, shall be completed on-site prior to the footing pour to verify that earthwork and foundation installation activities comply with the Geotechnical report or assessment recommendations. In addition a final inspection report, prepared by the engineer of record shall be required to verify that erosion control, drainage and final work is completed in accordance to the Geotechnical report or assessment recommendations. Reports shall be submitted to the Mason County Building Dept., 426 W. Cedar St., Shelton, WA 98584, prior to the footing and final inspections and available for inspection." I have forwarded the information on to our Enforcement Officer, Trish Woolett. Sincerely, Rebecca Hersha, Planner Mason County DCD 426 W. Cedar �' r Shelton, WA 98584 0 �` �Cp 360-427-9670 ext. 287 Pq /? < T �N Ty /`e file:///C:/Users/TrishW/AppData/Local/Temp/XPgrpwise/55BOC7DFMasonmail 1001626B6E 1541 FA 1/... 8/26/2015 1 7 __ 00 FRENCH HIP 5Y5. QQ 0 F71, VAULTED AREA 0 a O O ER TRU55 i ROOF V I EW REFER 70 5HOP DW55 E3Y 7RU55 MFR