Loading...
HomeMy WebLinkAboutPlumbing - PLN General - 6/11/1997 11/14/1001 11:06 4257020969 FAIRWAY MECHANICAL PAGE 08/10 3uivi D1 :-tA11Lt 6-11-97 4;3tPM REED McCLURC- 20648866144 2/ 4 City Itf Frnalo aci„s county N 199A 14-ftna1t 11,K!",Mernr R, ylm,,,R,u•ruUue 9euiUr.-Kind Ctr'un[y Dapnrt eeen/ 6/11"hik' 1111M1[h r` IWCCLVRE �Uvnzti T„�iouri�, i=6,U.,h1I'i(, llvp•Inr l�,e:v�o>�,�Ivia>Ima June 3, .1997 TO: Plumbing Program Persowel FROM: Lay Kirchner,Principal Fnvironment'tsl Elealth Specialist RE: Studor Air Admittance Vatves On September 27, 1996,the King County Hearing lrxarniner rendered a decision,allowing the use of air admittance valves produced and sold by Studor, Inc. j The Ex$milter's decision gave Studor the right to have their air admittancte vulvca used under the fallowing conditions: 1, In addition to the restrictions stated within the manufrictucar'S installation instxuctions,the followivag limitations on the use Of Studor air admittance valves Shall apply unless delailed plans demon4grating the tmhniral feasibility of applying(ess stringent limitxtiun,4 have beon propared by a fluensed plumblug contmetor or professional engineer and subridlted to and approved by the Seattle-King County Department of Public health: a. The main drain vent roquire,�d for cacti building shall include a full-sick vent through the roof,meetinb UPC standards. b. The two-inch.ytudor Mini-Vent air admittalx;e valve shall be used Only as an individual fixtae vent,a common vent Jbr two fixtures,or u single bathrnUm group wat vent. c. Air adtriittanLe valycs shall not be used a9 Vert( terminals for vent stacks or;stack, vents. ( I 4:gvtry►IMICuf�I IIa�4N MvWinn Y99'fI jr(j AvOnNt Suitn 109 y�unle,NMehi.gton 9010CWN t206)2W.1722 �-n Fl►rycied Gam• 11/14/2001 11:06 4257020969 FAIRWAY MECHANICAL PAGE 09/10 i ,, 1 �_1 ,1i Ni.LL' dhlLtKl 'UGltr cl!,i l:. L� 4 i The attorney for 5tudur,Inc has complained that our. staff are not following the conditions set forth by tlae Kitig County hero ing Txatniner. Although it is my init)ression Ilim the Plumbing inspectors am applyipg the eonditiow outlined by the Cwantiner, i want to reiterate the importance of providing consistent and unbiased inspectional activities. Plcmoc ensure that you are CuniiliHr wills the cundidown established by the King Cuway Heating Exivuiuer trust the technical literature applicable to rinse air admituutcc valves. It is any expectation lint all suxff will comply with(lie bxttmiaer's decision. Attached is a copy of the literature summary put togedwr by Bob Johns,Attumey 1'or Studor,lac. Mr.Jolms has provided the iitfonnation so that you will know%ldittt the Studor company is providing to potential cliaats. NU.Johns has assured me that he will talk with his client to reiterate the imporu=c o[giv.ing Olis literature to Ids cliculs in order to eliiuinate any confusion about the standards for use of the product. i Please coot.itiue to complete the funns lbr logging in Vie installation inronnation. 'Ilds inforwatiun is briportarld as we inorutor die installation process and perfunnance of these devices. Be sure to provide complete acid accurate infomintion on the insWlintion history. For mmmple,if valves are installed irtappropriutely or in a manner not consistent with the tnauuf:aeturt:r's invtmetious,this infurmaition should be noted. If you have tiny questions about thus incino, pleme cull are at 296-4731. 1 would be hahPY o t elaborate.�• 1�iS,:dm Attadirtictits: cc: Carl Ositki ,Chief,Environmental 11calth Services Cussundra Newell,Seniur Deputy Prosecuti%,.Attorney I i 11/14/21Jb1 11:06 4257020969 FAIRWAY MECHANICAL PAGE 10/10 " •'L!% ILL 11 d1 h"L•LU irILLLL-KL ;U�14{tll. 1l•x d. ! •� J INSTRUCTIONS FOR USE OF STUDOR AIR ADMITTANCE VALVES IN SEATTLE AND UNINCORI•'ORATED ICING COUNTY THE FOLLOWING REQUIREMENTS FOR THE USE OF S'i'UDOR AIR ADMITTANCE VALVES APPLY IN THE CITY OF SEATTLB AND IN UNINCORPORATED KING COUNTY; QF�r,li�: Studor Air Admittance Mini-Valves maybe used with' •'�r � y out prior approval of the Seattle-King County Department of Public Health if the following conditions am met; 1. Studor Mini-Valves am installed In accordance with the manufacturer's installntion instructions,and one the COUCIwing installations is used: ;r:•;, a) The:Studor Mini-Valve is used as an individual fixture vent,or bj The Studor Mini-Naive is used as a common vent for two fix(ures,or ' h, ;'�• c) Thu Studor Mini-Valve is used as a single bathroom group wet vent. 2. 71te main drain vent required for each building shall include a full-size vent thmugh the roof meeting UPC standards. Maxi-Valves and Mini-Valves may be used ' other Studor Air Admitlanca ligitionsonl if the following conditions are met: 1. Detailed plans for the vent system have been prepared by a licensed plumbing contractor or professional engioeer and submitted to and approved by the Seattle - King County Deparmnent of Public Health,and 2. Studor Valves are installed in accordance with the manufneturer's installation • tea:•,.:• Instructions,and 3. Tile main drain vent required for each building shall include a full-slze vetit tivough the roof meeting UPC standards. fig: Under either optiun 0 t or 92,air admittance valves ntay not be used as vent terminals for vent stacks or stack vents. xtq�,