HomeMy WebLinkAboutCorrection Notice - COM Inspections - 8/31/2007 NNW CALGD Engineering August 31,2007 4118 Kyro Fbad SE Larry Waters Oyrrpia,VGA 985M Mason County Community Development F0311W)7891-7591 P.O. Box 186 �I I:(360)789-18� Fax W)`-'&38M Shelton WA 98584 Re: Hood Canal School District Modernization&Additions Larry, I am responding to your"Correction Notice"from the site inspection on August 30th. Note, I'm responding to each line item by the numbers on your Notice. Item#1 — Will comply, signs are on site and will be installed by Jones& Roberts when striping is done. Expected completion by Sept.. 7, 2007. Item#2—Will comply, once site Storm Draining System is complete, I will call Public Works for inspection.At this time ponds are not complete. Expect completion by Oct. 1, 2007. Item#3 —Will comply, J&R is repairing by Sept. 17, 2007. Item#4—Will comply, inspection has been called for, Boilers will not be used until Certified by L&I. The Elevator has been approved by L&I. (See attached) Item#5 — A/E is working on response or design correction. Item#6—Will comply, will cut pipe off as requested, expect completion on August 31, 2007. Item#7— Our project Architect, Erickson McGovern claims smoke seals are not required on Classroom doors. Will comply on doors in 2 hour walls. Needs resolution with Mason County. Please note,plans were approved and built in accordance with the approved plans. May need some time for a resolution. Item#8—Will comply, expect completion on August 31,2007. Item#9—These doors were installed for security purposes"Only"to prevent Off Hour Users from going beyond the Commons, Gym and Library. We placed these doors so dead end corridors meet the 20 ft,rule. Design was reviewed with Mason County plan reviewer Kelly Mayo. It was agreed and approved exit doors and existing width comply with required IBC code. Needs resolution with the A/E Team and the County. Item#10—Will comply, I believe this is a Owner correction item in custodial rooms. Items will be corrected or disconnected. Item#11 —Will comply, Bollards on site, expect completion by Sept. 7, 2007. Item#12 —Will comply, expecting completion on August 31, 2007. Item#13 —Will comply, expect completion on August 31, 2007. Item#14—Confused about what's expected. The washer will not be used until resolved. *Please note,this is not a commercial washer. It will only be used to wash cleaning towels. The Health Dept. normally requires a wash machine as installed. Item#15 —Will comply, expect completion on August 31, 2007 or supplies will be shut off. Item#16—Need resolution,this is a Residential Stove. Stove will not be plugged in until resolved. Item#17— Will comply, expecting completion on August 31, 2007. Item#18 — Same as above. Item#19—Needs resolution, all pans have or will have drains to meet the code. Item#20— Same as above. Item#21 —Needs resolution, A.H.U. units can be removed or broken down. Can be removed from exterior make-up air louvers. Item#22 —Will comply, State Fire Marshal approves hood. (Lance Talley) Will not use hood until approved. Item#23 —Will comply, when we receive from our Contract Air Balancer, Advance Mechanical. Expect to have by October 1, 2007. Item#24—Will comply, will have Contractor or A/E Team provide cut-sheets. Item#25 —Will comply, expect completion A.S.A.P. Item#26—Will comply, have Contractor or A/E Team provide. Item#27—Needs resolution,this is a Residential Unit to wash soiled dish towels only, expect to be used 1 —2 times per week. Item#28— Will comply, expect completion on August 31, 2007. Item#29—Needs resolution, all 2 hour wall penetrations have been sealed. Will verify others with A/E Team. Not sure if it's a code issue. Item#30—Will comply, I believe relief drain is piped to waste lines on the first floor. Will confirm. Will not use heater until resolved. 2 Larry, in closing, I hope I have addressed all the concerns in your Correction Notice so Mason County can issue a Temporary Occupancy Certificate so the Staff and Students can occupy the facility on September 4, 2007. Also, I would like to emphasize that the 2 hour walls, on approved plans were not a required code issue. The walls were a negotiated issue with the State Fire Marshal, because of the inadequate water storage volume for fire flow requirements. Please note, we also installed non-code smoke detectors in all classroom spaces as agreed with the jurisdiction involved. F.Y.I we have on site 60,000 gallons of on site storage for fire protection and fire sprinkler system along with Skykomish Tribe hydrants which can provide 1,000 GPM @ 20PSI residual on S.R. 106. We have appreciated working with Mason County on this project for the Students, Staff and the Community. If we have a few resolution items to resolve I hope that Mason County will be understanding and allow us a Temporary Occupancy Certificate. Again, I thank you, and if you have any questions please contact me at(360)491-7591 or cell (360) 789-1865. Sincerely, 6aryyy . Larson, P.E,Project Manager P.S. Please see attached email comments/responses from our Project Architect, Erickson—McGovern and our Mechanical Engineer, BCE. cc: Robert Jones; Jones&Roberts Ray Mow; Erickson—McGovern Ron Zier; Hood Canal School District GAL/sal 3