Loading...
HomeMy WebLinkAboutCOM2010-00091 Sign - COM Permit / Conditions - 9/30/2010 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton,WA 98584 too • COMMERCIAL BUILDING PERMIT COM2010-00091 OWNER: HOOD CANAL SCHOOL DISTRICT#404 RECEIVED: 9/20/2010 CONTRACTOR: DOGWOOD CONSTRUCTION 360-898-6102 LICENSE: DOGWOC1990R4 EXP: 12/24/2011 ISSUED: 9/30/2010 SITE ADDRESS: 111 N STATE ROUTE 106 SHELTON EXPIRES: 3/30/2011 PARCEL NUMBER: 421023460000 LEGAL DESCRIPTION: S1/2 OF SW EX &VAC RESERVATION RD ADJ PROJECT DESCRIPTION: DIRECTIONS TO SITE: Construction of New Reader Board Sign US Highway 101 North, R on St Rt 106, then left into the school. General Information Construction&Occupancy Information No. of Units: Type of Constr.: Type of Use: School Insp. Area: No. of Bathrooms: Occ. Group: Type of Work: ACC Fire Dist.: g No. of Stories: Exit Design. Load: Valuation: $ 6,800.17 Building Height: 12 Pre-Manufactured Unit Information Square Footage Information Make: Length: Lot Size: Model: Width: Building: Year: Serial No.: Basement: Parking Spaces: Setback Information Shoreline& Planning Information Front: S 30.00 Ft. Shoreline: Ft. Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.: Not Applicable Side 1: Ft. SEPA?:Unknown Comp. Plan Desig.: Side 2: Ft. Fire Protection System Information Auto Fire Alarm System?: Emergency Key Box?: Standpipe?: Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?: Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?: COM2010-00091 Please refer to the following pages for conditions of this permit. 1 of 5 Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee MAM Q/9n/9nin aQn r,1 Si gmnnn Planning Review Fee r.KAM Q/9n/9nin 07n nn gi9mnnn Building State Fee nnFr. Q/9Q/?nin Qd 5n Glgntnnn Building Permit Fee nnFr. QnQnnln ,t1iQ)r, S1,nlnnn Total $304.26 CASE NOTES FOR COM2010-00091 CONDITIONS FOR COM2010-00091 1) 3000 PSI CONCRETE WILL REQUIRE SPECIAL INSPECTION IF THE QUANTITY EXCEEDS 50 CUBIC YARDS< LESSER AMOUNTS WILL REQUIRE AN APPROVED CONCRETE SUPPLIER TO PROVIDE YOU WITH A BATCH TICKET AT WILL BE REQUIRED TO BE SUBMITTED TO THE SITE INSPECTOR FOR THE VERIFICATION OF MATERIAL USED. X /_ 2) Owner/Agent i sponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X , 3) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF U50R OCCUPANCY WOULD RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x 4) Changes to approved building plans that affect compliance to the current Washington State Energy Code (WSEC), ventilationrequirements), Build in lining/Mechanical Codes and/or Mason County Regulations shall be approved prior to construction. X 5) Any changes in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are removed, approval will not be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected a Mason County Building Department prior to any further inspections being performed or approvals granted. X 6) CO STRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason t:Bj.lilding Inspector shall be made prior to requesting additional inspections. X COM2010-00091 2 of 5 7) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-cojpVant with Mason County ordinances and building regulations. X f� 8) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of t27iit holadr have prevented action from being taken. No more than one extension may be granted. X 9) All approved plans are required to be on-site for inspection purposes. If inspection is called for and plans are not on site, Approval WILL NOT be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour w a charged and collected by the Mason County Building Department prior to any further inspections being performed or approvals granted. X 10) All property lines shall be clearly identified at the time of foundation inspection. X 11) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-9,902. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 12) Setbacks on highway frontage is measured from the edge of the easement. Easement width is established by State DOT. 13) ApproyM per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 14) The approved site plan is required to be on-site for inspection purposes. If inspection is called for and the site plan is not on site, Approval WILL NOT be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by the Mason Coun ilding Department prior to any further inspections being performed or approvals granted. X 15) An inspe tion performed by the engineer of record or thier representative shall be completed on-site during the compaction of quarry rock, prior to the footing pour and during the compaction of native backfill to verify that earthwork and foundation installation activities comply with the engineers report and recommendations. Reports shall be submitted to the Mason County Building Dept., PO Box 186, Shelton, WA 98584, prior to the footing and final inspections and available fn ion. X T 16) In addition to the inspections required in IBC, Section 109, the owner, the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by the design professional. The special inspectors duties& responsibilities shall be as specified in Chapter 17. Special inspection reports shall be submitted to the Mason County Building Department, PO Box 186, Shelton WA 98584 and available for inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and final o pections. X � COM2010-00091 3 of 5 17) The image and/or message shall remain fixed for at least 5 seconds and the only animation or appearance of movement allowed is the transition from on ssad/or image to another by the scrolling on and/or off of the message and/or image. X 18) The size, to ation, movement, content, coloring or manner of illumination shall not be confused with or construed as a traffic control sign, signal or device, or the light of an emergency or radio equipment vehicle, or obstruct the visibility of traffic or street sign or signal device from the traffic intended a served by the sign, signal or device. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: i� ���� DATE'< �� COM2010-00091 4 of 5 n O 2 N) CONCRETE MECHANICAL MANUFACTURED HOME O Date By 0 o Footings 1 Setbacks Ribbons o Gas Piping n o intenor Date By interior-Date By Date By D o cm Fxten r Date By Exterior-Date _ By $et-up D Point Load 1 Isolated Footings S SLAB I1 O ULATION Date By Cn Date By Data By FIRE DEPARTMENT = Foundation Walls Floors Date By O Date By Data By DECKS 0 F RAM I NG Walls Date By p Date By Data By PROPANE TANKS PLUMBING vault Date By Date By OTHER 0 Groundwork Attic Date By Date By Type: *k Date o.w.'v DRYWALL Type: By O Int Brace Wall Date By Date a Date w _._..___. By 9 y FINAL INSPECTION N L Water Line Fire Separation Date By • Date By Data By I?O Pass or Request Inspect. o Type of Insp. Fail Date Date Done By Comments /D—l7 —10 C // ff 0 U1 PLANNING SEP 2 3 2010 • ALL SETBACKS ARE MEASUREDi FROM THE FURTHEST MASON COUNTY PROJECTION OFTH — — Q I I r�iolo- hIA- '� WlilAlD Sf1UGR 0.{'MIN. _ Qoruronvwa r v f —E%iEMawEiUND �D.. /\\ • ��1 �r.l6p a„MM 1 ���� , ;� d • � I 1 r m nuwq x¢e '+op \ 0-1: TIE T j \` ' op �o ViU o i deb \`\ n �� _/ I'' ) O a lo i.lima'.ne �� 1 A PROVED / pawn: .--dASON NTY DCD NNINGI I - � / J wxco Innw SITE RA REQUIRED TO.W ON SITE CHAWES SUBJ TO APPROVAL co ='L„ .co�u.olroloulxmea.aa« ( rl.cs o �. onrwow�r wr.,'we.caA.e � J - DYW _ AO:y OVE A 1.01 __omlre trrun waosmnµ'iw�'a0° wauau l>.wlawo MASON COUNTY PERMIT NOCAM 2010-Odd 1 BUILDING PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670• Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner_ i+rM 44NAL jgfn L i'qD+ Company Name DO&,,,l,""� 6"Wt4001 // . Mailin Address I n . �41, -f,G. it% —� Mailing Address CitySiLI6= State_WA Zip Code '19531±E City Ua4z'21 State /� Zip Code 985:� Phone �O—A-72-5_460 Other Ph. Phone - ' Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address E Mail Address 1&A-) et%1,A,r11z4 Gc*)1t Y.rl, d/1 �07Y1f Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Water System Name of Water System PARCEL INFORMATION.- 12 Digit Parcel No, )CQ.:3146,06 O Fire District Legal Description LS 1A I�E SW CA -j Vt}C tA?CZ1'J 1 hf�r_ Site Address(Please include street name, street number and city)_ ill Q . Aii odC�� 10'A Directions to site &41 a fU 4�4hL4� Will timber be cd ands d in parcel preparation?Yes/ o Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs ] 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building Is—Describe Work_. ,SGkyl i'1RG(tY' I � i No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor 2nd Floor 3rd Floor Basement Deck Covered Deck Other Sq.ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION -Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOFPE&ONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION.�,J X f Date ole� Owner/Owners Re resentati e/ tractor (indicate which one FOR OFFICIAL USE BEYON OINT Accepted b . i Date — (� DEPARTMENTAL REVJEW APPROVED DENIED NOTES Building Department Planning Department Environmental Health Department Public Works Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planninq Review Fee Mechanical& Base fee Other Wood/Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation$ TOTAL FEES DATE JOB NO. M.E.T. MORTA ENGINEERING & TESTING PROJECT _ 1018 E.Wishkah St. Aberdeen,WA 98520 LOCAnON f smorta@aol.com G. Business:(360)28199--_0i95�/8// Tfoj/li Free: 1-8_0_0-5590-0958 CONTRACTOR OWNER TO ` /j�w" 6��:: 1!!./l (JLi" wEATNER TEMP. °al AM fat PM ea _ PRESENT AT SITE ARRIVAL TIME: DEPARTURE TIME:�• y-S��' THE FOLLOWING WAS NOTED: I� on E 1 s i` \_ Ir1, Jr. ••fir � r �� f�� I' i c— 10,7 - f-/U4-11 i i COPIES TO �. �� FIELD E P O R SIGNED i MASON N COUNTY I Department of Community Development jINSPECTION CARD and CERTIFICATE OF OCCUPANCY* i I C 0 BOX 186, 426 W Cedar ST, Shelton WA 98584 General tions: (360) 427-9670 ext 352 Inspection Requests: (360) 427-7262 Permit Number COM2010-00091 Date 09/30/2010 Issued By Project Construction of New Reader Board Sign Site Address 111 N STATE ROUTE 106 SHELTON Applicant HOOD CANAL SCHOOL DISTRICT#404 Contractor DOGWOOD CONSTRUCTION License Number DOGWOC1990R4 Con. Phone 360-898-6102 Expiration Date 12/24/2011 Primary Code 2009IBC Occupancy Division Use School Type of Construction Exit Design Load Public Works Access/Driveway Other Health Dept Septic Well Planning Dept Site Inspection Fire Marshal Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Dept Building Official: Community Development Designee Concrete Setbacks JD— 2 1— / Slab Footing Perimeter qZ--- /v—2- Ret. Wall /Bulkhead Footing Interior Footing Decks/ Porches See 6"'K 1> Foundation Stem Other Rough-In Groundwork Plumbing Plumbing Groundwork Mechanical Other Groundwork Gas Pipe Gas Piping Framing Mechanical Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Nailing Interior Wall Brace Panels Fire walls Other Final Building Manuf. Home Setbacks Setup Concrete Foot/ Runners Final Other APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS "THIS STRUCTURE MAY NOT BE USED FOR OCCUPANCY UNITL ALL APPLICABLE FINAL INSPECTIONS ARE COMPLETED DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVALS ARE GIVEN. POST THIS CARD IN A CONSPICUOUS PLACE ON THE FRONT OF THE PREMISES CONVENIENT FOR MAIQING REQUIRED ENTRIES. ALL PERMITS EXPIRE 180 DAYS AFTER PERMIT ISSUANCE OR 180 DAYS AFTER LAST INSPECTION ACTIVITY IS PERFORMED. OWNER/AGENT IS RESPONSIBLE FOR CALLING FOR ALL INSPECTIONS PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMT MUST BE MET. i Request To Revise An Approved Plan GO Y'Yl ,gyp 10 _ CCU I Name 1�0 6 - I UVC� 0 o nS Permit Number: —E � c Parcel Number d Z l - _-�p�Q(Z Phone Number dayti ) Project Address 111 �-' Mailing Address (o 1 C)U L o.A C1 FS5e>,J Please provide a complete, detailed d ription of the proposed revisions to the approved plans: 1 ' ' 2, 6 no F E1 Are two sets of the revised plans or addendum indicating the changes included? ❑ Yes �i<No Are the approved site plans included? ❑ Yes )<No Are the revisions clearly and accurately identified on the plans or addendum? INS<Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? )eyes ❑ No If Yes, Has the engineer or architect approved this revision? >�Yes ❑ No Is a stamped and signed'approval included with this request? xYes ❑ No (Note:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record.) Does the proposed revision modify the footprint or location of the structure? ❑ Yes )<No If Yes, Is a revised site plan, with all new setback dimensions included with this request? ❑ Yes ❑ No Additional Information: Applicant's signature Date: \,3 e) L[� Office Use Only Received by: Date Sent Assigneq To I Approve By Date B Original Valuation: $ L 1� — � Additional Valuation: $ P. Sq. Ft. x$ $ Sq. Ft. x$ $ Total New Valuation $ Additional Fees: Additional Planning Dept. $ Additional Plan Review $ Additional Con itions/ ments: Additional Building Permit $ av Additional Plumbing $ Additional Mechanical $ Additional E. H.Dept_ $ ' Other $ NJ Total Amount Due: $ Amount To Be Paid Up-Front$ DOGWOOD CONSTRUCTION, INC. New Construction ' Remodels ' Garages ' Repairs DOGWOCI 9WR4 320 E.Dalby Road Union,WA 98592 (360)898-6100 ' Fax(360)89"102 OWN www.doawoodconstruction.corn1997 2, 7info.a`ZdoQwoodconstruction.com*40,9�- _ P FAX - COVER SHEET FAX # 360-427-7798 Date: 3/31/2011 Attention: Bulling Department Re: Hood Canal School Sign 3 - Pages sent including this cover letter Thank you- Cherry 6'd Z069 869 M, QOOMO00 eCV60 l6 68 JeA Request To Revise An Approved Plan Permit Number-B kl3l, - 0 011' I Nam C 'l Parcel Number 2 1 D - 3 -j Phone Number da ime (7r,41- ) Project Address Ll t IJ � Z( Mailing Address Please provide a complete, detailed description of the proposed revisions to the approved plans: Are two sets of the revised plans or addendum indicating the changes included? Yes ❑ No Are the approved site plans included? ,Z Yes ❑ No Are the revisions clearly and accurately identified on the plans or addendum? q Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? cK Yes ❑ No If Yes, Has the engineer or architect approved this revision? Yes ❑ No Is a stamped and signed approval included with this request? Yes ❑ No (Note:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record.] Does the proposed revision modify the footprint or location of the structure? ❑ Yes ❑ No If Yes, Is a revised site plan, with all new setback dimensions included with this request? ❑ Yes ❑ No Additional Information: Applicant's signature T Date: 47��J Office Use Only A�_ Received by: Date Sent Assigned To Approved By Date Original Valuation: $ B. Additional Valuation: $ Sq. Ft. x$ $ Sq. Ft. x$ $ H Total New Valuation $ Additional Fees: ❑ P.W. Additional Planning Dept. $ Additional Plan Review $ Additional Conditions/Comments: Additional Building Permit $ Additional Plumbing $ Additional Mechanical $ Additional E. H. Dept. $ Other $ Total Amount Due: $ RECEW Be Paid Up-Front$ 426 W. CEDAR ST. EnCon Services, Inc. Sign Design Calculations Job Description PREPARED BY: EnCon Services, Inc. Hood Canal School 2272 Jaudon Road 111 N. Hwy 106 Dover, FL 33527 Skokomish Nation, WA 98584 813-655-3373 12'-0" monument sign F 813-655-9814 Design per ASCE 7-05 Aaron Biedenbach, P.E. FL PE#52949, FL EB 9394 Importance Factor 1 OH PE 60756, OC#01893 Kzt 1 KY PE #20281, P#2463 Exposure C IN PE#PE 19600322 Kd 0.85 FL CBC#060535, QB#22527 Kz 0.85 v 85 mph Cf 1.73 G 0.85 Wind Pressure Number of Poles=2 1 20 PSF Sign Area Distance to Center P=Force Moment sf ft Qb) ft-lb) Top 35.40 9.50 696 6609 Middle 0 0 Bottom 21.42 3.85 421 1621 Poles 0 0 Totals Per Pole 1,117 8,229 Required Sx 5.20 inches cubed per pole Provided Sx 9.11 5"x5"x3/8"6061-T6 Aluminum Tube OK Anchor Bolt Design Distance Between Bolts 11 8977 Tension on Bolts(LB) Number of Bolts per Base Plate 2 Use 1-1/4" Dia.X 36" Long F1554 Gr 36 Bolts w/4" L-Hook Embedded in Concrete Footer 111r///J1.Opo JA,Q grEDENeq; ` Q r • NO • a' �jk% 4416 3/14/2011 Hood Canal School 5kokomish Nation WA 12-0 rob mon R2 pole thru sign 85 mph _ 1 EnCon Services, Inc. Sign Design Calculations Job Description PREPARED BY: EnCon Services, Inc. Hood Canal School 2272 Jaudon Road 111 N. Hwy 106 Dover, FL 33527 Skokomish Nation, WA 98584 813-655-3373 12'-0" monument sign F 813-655-9814 Design per ASCE 7-05 Aaron Biedenbach, P.E. FL PE#52949, FL EB 9394 Importance Factor 1 OH PE 60756, OC#01893 Kzt 1 KY PE #20281, P#2463 Exposure C IN PE#PE 19600322 Kd 0.85 FL CBC#060535, QB#22527 Kz 0.85 v 80 mph Cf 1.73 G 0.85 Wind Pressure Number of Poles=2 1 17 PSF Sign Area Distance to Center P=Force Moment sf ft (ib) ft-lb) Top 35.40 9.50 616 5854 Middle 0 0 Bottom 21.42 3.85 373 1435 Poles 0 0 Totals Per Pole 989 7,289 Required Sx 4.60 inches cubed per pole Provided Sx 9.11 5"x5"x3/8"6061-T6 Aluminum Tube OK Base Plate Design Distance Between Bolts 11 7952 Tension on Bolts(LB) Number of Bolts per Base Plate 2 Use 1-1/4" Dia.X 36" Long F1554 Gr 36 Bolts with 4" L-Hook Base Design Number of Bases 1 Diagonal B(FT) 5.83 Base Size Required Lateral soil pressure(LB/SF/FT) 100 4.0 FT Deep Depth (Estimated) (FT) 4 5.0 FT Parallel To Sign Face S1 356 3.0 FT Perp.To Sign Face Design Depth(FT) 3.60 Ft ���, Q• B�EDFN''' 1480 No52 ; 1t ATE F kI f v 11 S/0 N A���►���� �01/ ///1 2/28/2011 Hood Canal School Skokomish Nation WA 12-0 rob mon R1 revised pole thru sign EnCon Services, Inc. Sign Design Calculations Job Description PREPARED BY: EnCon Services, Inc. Hood Canal School 2272 Jaudon Road 111 N. Hwy 106 Dover, FL 33527 Skokomish Nation,WA 98584 813-655-3373 12'-0"monument sign F 813-655-9814 Design per ASCE 7-05 Aaron Biedenbach, P.E. FL PE#52949, FL EB 9394 Importance Factor 1 OH PE 60756, OC#01893 Kzt 1 KY PE #20281, P#2463 Exposure C IN PE#PE 19600322 Kd 0.85 FL CBC#060535,OB#22527 Kz 0.85 V 80 mph Cf 1.73 G 0.85 Wind Pressure Number of Poles=2 1 17 PSF Sign Area Distance to Center P=Force Moment sf ft (ib) ft-lb Top 35.40 9.50 616 5854 Middle 0 0 Bottom 21.42 3.85 373 1435 Poles 0 0 Totals Per Pole 989 7,289 Required Sx 4.60 inches cubed per pole Provided Sx 9.11 5"x5"x3/8"6061-T6 Aluminum Tube OK Base Plate Design Distance Between Bolts 11 7952 Tension on Bolts(LB) Number of Bolts per Base Plate 2 Use 1-1/4" Dia.X 36" Long F1554 Gr 36 Bolts with 4" L-Hook Base Design Number of Bases 1 Diagonal B(FT) 5.83 Base Size Required Lateral soil pressure(LB/SF/FT) 100 4.0 FT Deep Depth(Estimated) (FT) 4 5.0 FT Parallel To Sign Face S1 356 3.0 FT Perp.To Sign Face Design Depth(FT) 3.60 Ft Q` . 49 *� . Q • Nos -o00• a • •• N A 'j 2/28/2011 Hood Canal School Skokomish Nation WA 12-0 rob man R1 revised pole thru sign EnCon Services, Inc. Sign Design Calculations Job Description PREPARED BY: EnCon Services, Inc. Hood Canal School 2272 Jaudon Road 111 N. Hwy 106 Dover, FL 33527 Skokomish Nation,WA 98584 813-655-3373 12'-0" monument sign F 813-655-9814 Design per ASCE 7-05 Aaron Biedenbach, P.E. FL PE#52949, FL EB 9394 Importance Factor 1 OH PE 60756, OC#01893 Kzt 1 KY PE #20281, P#2463 Exposure C IN PE#PE 19600322 Kd 0.85 FL CBC#060535, OB#22527 Kz 0.85 V 80 mph Cf 1.73 G 0.85 Wind Pressure Number of Poles=2 1 17 PSF Sign Area Distance to Center P=Force Moment sf ft (ib) ft-lb) Top 35.40 9.50 616 5854 Middle 0 0 Bottom 21.42 3.85 373 1435 Poles 0 0 Totals Per Pole 989 7,289 Required Sx 4.60 inches cubed per pole Provided Sx 9.11 5"x5"x3/8"6061-T6 Aluminum Tube OK Base Plate Design Distance Between Bolts 11 7952 Tension on Bolts(LB) Number of Bolts per Base Plate 2 Use 1-1/4" Dia.X 36" Long F1554 Gr 36 Bolts with 4" L-Hook Base Design Number of Bases 1 Diagonal B(FT) 5.83 Base Size Required Lateral soil pressure(LB/SF/FT) 100 4.0 FT Deep Depth (Estimated) (FT) 4 5.0 FT Parallel To Sign Face S1 356 3.0 FT Perp.To Sign Face Design Depth(FT) 3.60 Ft ,I�� Q, SIEDFM • No 52Au ••*' 0 TAB a '�., 0 N A� ��► 2/28/2011 Hood Canal School Skokomish Nation WA 12-0 rob man R1 revised pole thru sign N a EnCpn Services,Inc. ui�n Desryn Ca}tulalla+tl bti Date:+Nw; PACPArIED BY:En;;c•1 S^n+raes,Inc. 1t-J OKA kiVA l 2272 Ja-uan Road 11!a Hwy IN rnmt,IT 385V 9kt4,;:m4h f mWv,WA 983s1 81M55-3973 IT-0"mcwmrnl.sign F R J.".9r-qp 14 Dorn w ASCE 7.05 N Aamn�odarllaca,P.E. O FL PE Y3294a,FL EB 2394 I'npo mnoe Favor 1 OH PE 00759,OC a018d8 Yzl 1 KY PE 420281,P 42453 Co BxpoBula IN PE WE 19600322 G) Ku 0•L'ti Pi.C8C 006055S,QB 022327 00 K1 0.85 O Y 85 mph Cl 1.73 A 0.25 Wind Precaure fd1:Aff of Pc!ae 2 1 20 PBF II dgn 4t l:hlnntoC401ar ,.r.e gln!nnnl Top r5.40 9.50 1196 8809 0 cc IMddia 0 0 t■w' a 3 Botla',I 21.42 3.05 4TI 1021 Putus 0 0 Q Z Totals Par Pala 1,117 t1,228 ♦f'4 p fiocplkea 5i ti.20 Mcim oubud 9ot9Cli N O areridod 8x U l S't5'x3/8'6001•T3 AlumAw!n TuLv OK w M Anchor Boll .sIT, Q a n DISla!ra Butraen Boh 11 3477 Tension on balks(LB) = O U Pl,+mbar of p01s p1•Bs;o Pmla 2 the 1-1/4"Dia.X 30"Lang F1594 Or 86 Both Cy vd4^L.Haok I:mbeddsd 1n Cot%jots Foo!sr O m� �a rn � 1 • tiax �tQf :pn u.• 3075rS 0 ` Alt i p'°Rt fi1�T.•{�����` m M ?:1t7•:11 � hleadhwl:Jrcd S^.iaaal,thU-.ttVh if-OraS moe k-pr.:•th;se�n 37,yJ. G O (h r M I — d j� Y FRAME —� � 7' _ 6 1 9" SX'TRUDED ALUMINUM FILLER C) 1/8" VELDED SHEET STIFFENER _ — 3 LAbIP WIR12 RACEWAY 2° X 2" X 3/16"ALUMINUM ANGLE WkWED 1 I I I I 5 RAL[AST - P7PTIP CW/IfO 2 RRgIIFRRD in 6 LAMPS - I'AOT12 CW/HU. 5 REQUIRED N I i I 7 SOCKETS - KULRA DOUBLY CONTACT SNAP IN n 0 1 { I I LAMPHOLDERS 662 & 683 f~y! 8 11/it" X 1 1/2" X 1/6' ALUMINUM ANGLE RETAINER � II I D 5" 6" X 3/D" SQUARE 0001^70 ALUMINUMTUDINC 00 l0 NOT USED I ' s�) I 1 I I 4f� 11 ALUViNIIM FOOT `IEEE DETAIL, 2 REQUIRED f l -... - 12 E �4" DIA 1 36" F1654 GR 36 'd' DOLTS k NUTS, 4 RE4ULRED bIt Ct� EtiIVFIDED INTO CONCRETE FOONDATION DESIGNED BY OTHERS � p 1 �I 14 NOT li$ED A i .Z f• '� \ _ 2'C � 15 ELECTRONIC MESSAGE CRNM 20 POWDER COATED FINISH 17 LEG POSTS WRI-DSO TO FRAMEJI- As-*.,v 3ZS-7oi/ NOTES ' NXTORIOR FINISH - ?MIR COATED e r TJIMPV INCLUDen ;U.L. " 11 r I limb 7 EUCTRIC.U. — 3.K ARK 120 VACI—A I{ FRAME. � LAMP DETAIL FACE `=�' I!�l� rl�--�` �cLEcAN esr RUN UNDER A 1 3" PANFORRED PDI.YCABVQNA4E CUAi: GOUND IN } H ACE DECORATION PER ROBSON CORD- AR"ORK CONDU1i i 6ew ` CROSS SECTION ❑ I �•Pl IENCON SERWES. INC. 1l AN 3!MFNRACH PORYANC.FACrM- t o 2272 JAUCON ROAC cxPOSURE C 4EN8 4 — DOV R, FL 3352Y AtU 7-0! (� + 75' ,�: 42 O ' � PLPE )52949, FLED y9:551 a Di I 4 140 O1Pp 6 60756, OC It.0189•. ^I Y '� �C fr 1 t , br r 1. �:0 IN p,PE IS600322 ri �yla It741R1.�'�1�1 1SiZE MN: NG:n CANALsc:VUL °�/ii/JNl u 111 N. HWt. 105 ' GRAP111C DETAIL FOOT DETAIL - - SKOKOVS4 N,0;CN,WAS11111GTON 98b84 _. �ChL ! KVI$ION R2 SHEET 1 OF 1 EnCon Services, Inc. Sign Design Calculations Job Description PREPARED BY: EnCon Services, Inc. Hood Canal School 2272 Jaudon Road 111 N. Hwy 106 Dover, FL 33527 Skokomish Nation, WA 98584 813-655-3373 12'-0"monument sign F 813-655-9814 Design per ASCE 7-05 Aaron Biedenbach, P.E. FL PE#52949, FL EB 9394 Importance Factor 1 OH PE 60756, OC#01893 Kzt 1 KY PE #20281, P#2463 Exposure C IN PE#PE 19600322 Kd 0.85 FL CBC#060535, OB#22527 Kz 0.85 V 85 mph Cf 1.73 G 0.85 Wind Pressure Number of Poles=2 1 20 PSF Sign Area Distance to Center P=Force Moment sf ft (lb) ft-lb) Top 35.40 9.50 696 6609 Middle 0 0 Bottom 21.42 3.85 421 1621 Poles 0 0 Totals Per Pole 1,117 8,229 Required Sx 5.20 inches cubed per pole Provided Sx 9.11 5"x5"x3/8"6061-T6 Aluminum Tube OK Anchor Bolt Design Distance Between Bolts 11 8977 Tension on Bolts(LB) Number of Bolts per Base Plate 2 Use 1-1/4" Dia.X 36" Long F1554 Gr 36 Bolts w/4" L-Hook Embedded in Concrete Footer g1EDEN�% p % y a . No ��[ • W SIGN P►� ►► 3/14/2011 Hood Canal School Skokomish Nation WA 12-0 rob mon R2 pole thru sign 85 mph 4 3 5 4 1 FRAME CHANGES A 6 7 1 9" EXTRUDED ALUMINUM FILLER SUBMIT CHANGES FOR APPRO 7 2 1/8" WELDED SHEET STIFFENER PRIOR TO PERFORMING WOR 3 LAMP WIRING RACEWAY B 4 2" X 2" X 3/16"ALUMINUM ANGLE WELDED o f I I I I 5 BALLAST - F72T12 CW/HO 2 - REQUIRED 6 LAMPS - F96T12 CW/HO, 5 REQUIRED Ln I I I I 7 SOCKETS - KULKA DOUBLE CONTACT SNAP IN I I O I I LAMPHOLDERS 582 & 583 I I I I 8 1 1/2" X 1 1/2" X 1/8" ALUMINUM ANGLE RETAINER I 9 5" X 5" X 3/8" SQUARE 6061-T6 ALUMINUM TUBING 10 NOT USED 4 I I I I 4 11- ALUMINUM FOOT SEE DETAIL, 2 REQUIRED 12 1-1/4" DIA z 36" F1554 GR 36 'J' BOLTS & NUTS, 4 REQUIRED EMBEDDED INTO CONCRETE FOUNDATION DESIGNED BY OTHERS 14 NOT USED w c11 Z Q 9 2 c c • 15 ELECTRONIC MESSAGE CENTER 8 8 16 POWDER COATED FINISH 17 LEG POSTS WELDED TO FRAME 16 NOTES EXTERIOR FINISH - POWDER COATED LAMPS INCLUDED 11 2 U.L. LISTED ELECTRICAL - 3.8 AMPS. 120 `XC II 11 II II FRAME & LAMP DETAIL II 11 ELECTRIC CAN B FACE 12 RUN UNDER A 1/8" PANFORMED POLYCARBONATE - CLEAR GOUND IN B FACE DECORATION PER ROBSON CORP. ARTWORK 1/2" CONDUIT 5' 9' 1• 1,625'0 CROSS SECTION ENCON SERVICES, INC. 85 MPH WIND LOAD B�E� '%� AARON BIEDENBACH IMPORTANCE FACTOR 1.0 o ,1� Q 4 �� 2272 JAUDON ROAD EXPOSURE C F z 11 ❑C � •.•EN•.• Bq DOVER, FL 33527 ASCE 7-05 A o CD `NA ; •. • 813-655-3373 ® o 0 13,875' Q: • Z FLPE #52949, FLEB #9394 D *& Q % Np 52 OHPE #60756, OC #01893 a W; KY #20281, P #2463 C Z =�0- A IN #PE 19600322 ��► SIZE LOCATION: HOOD CANAL SCHOOL FOOT DETAIL "'' B N. HWY. 106 SK GRAPHIC DETAIL SKOKOMISH NATION, WASHINGTON 98584 SCALE %&O REVISI❑N R2 SHEET 1 OF i