Loading...
HomeMy WebLinkAboutCOM2005-00135 Change in Tenant - Collision Repair and Spray Booth - COM Permit / Conditions - 2/1/2006 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext. 352 Shelton, WA 98584 iT COMMERCIAL BUILDING PERMIT COM2005-00135 OWNER: EXTREME AUTO RECEIVED: 12/6/2005 CONTRACTOR: LICENSE: EXP: ISSUED: 2/1/2006 SITE ADDRESS: 1383 E SHELTON SPRINGS RD SHELTON EXPIRES: 8/1/2006 PARCEL NUMBER: 420122190102 LEGAL DESCRIPTION: LOT: 2 OF SP#2968 PTN TR 10 NE NW PROJECT DESCRIPTION: DIRECTIONS TO SITE: CHANGE OF TENANT FROM CLASSIC AUTO/RV STORAGE SHELTON SPRINGS, SHARED DRIVEWAY WITH 1381 E SHELTON TO COLLISION REPAIR& INSTALL SPRAY PAINT BOOTH SPRINGS RD. GMM General Information Construction &Occupancy Information No.of Units: Type of Constr.: IIB Type of Use: Automotive Insp.Area: No.of Bathrooms: 1 Occ. Group: S1 Type of Work: ALT Fire Dist.: No.of Stories: 1 Occ. Load: 20 Valuation: $ 7,395.00 Building Height: Pre-Manufactured Unit Information Square Footage Information Make: Length: Lot Size: Model: Width: Building: 3,750 Year: Serial No.: Basement: Parking Spaces: Setback Information Shoreline&Planning Information Front: Ft. Shoreline: Ft. Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.: Side 1: Ft. SEPA?: Comp. Plan Desig.: Side 2: Ft. Fire Protection System Information Auto Fire Alarm System?: Emergency Key Box?: Standpipe?: Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?: Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?: COM2005-00135 Please refer to the following pages for conditions of this permit. Page 1 of 5 Plumbing Fixtures Mechanical Fixtures FEES Type Qty, Type Qty. Type By Date Amount Receipt Furnace<100K 1 Plan Check Fee KKK i9iRi9nnR A197 nn gggnnRn EH Plan Review r.Fw 19/iA/9nn It75 nn glgnnrn Plan Check Fee ni r. vavgnnR App Ri c19nnRn Building State Fee ni r 1/,A1/9nnR .ta Rn gignnRn Building Permit Fee ni r. 1i141i9nnR A1S,A 95 gignnRn UFC Plan Check Fee ni r 1/z1i9nnR Rap R1 gi9nnan Mechanical Fee ni r. 9i1ai9nns a14 An g99nnRn Mechanical Base Fee ni ?i1�i9nnR (t9A sn cggnnrn Total $547.47 CASE NOTES FOR COM2005-00135 CONDITIONS FOR COM2005-00135 1) Changes to approved building plans that affect compliance to the current Washington State Energy Code (WSEC), ventilation and Indoor Air Quality Code (VIAQ), Building/Plumbing/Mechanical Codes and/or Mason County Regulations shall be approved prior to construction. X 2) This project is approved without structural changes to the building. Exhaust systems required by the manufacturer of the spray booth shall not affect structural members and shall maintain required setback from combustible materials as required by the manufacturer installation specifications. X 3) Lighted exit signs are required at all exit doors. Battery back-up emergency lights are required in all storage areas and exit corridors. X 4) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 5) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X COM2005-00135 Page 2 of 5 6) The requirements of the International Fire Code chapter 26 "Welding and Other Hot Work" shall be adhered to. A copy of the chapter has been included with the review. X An automatic fire alarm system meeting NFPA 72 and Mason County standards and monitored by an UL certificated monitoring company shall be installed in this building. Information indicates a disconnected system currently exists that may need upgrading. Separate plan and permit is required. X - A rapid access "Knox" key box is required for this building. Contact Mason County Fire District# 11 at 360-426-1822 for an application and mounting instructions. X Minimum 3A40BC rated fire extinguishers are required to be within 30 feet travel distance in approved locations and mounted no more than 48 inches from the finished floor to the top of the extinguisher. X Fire apparatus access roads chapter 14.17 of the Mason County Building Code shall be adhered to.X 7) This permit is approved for the UL listed spray booth only. A separate permit is required for the fire suppression system which will be reviewed by and approved by the Mason County Fire Marshal. The fire suppression system shall be connected to the building alarm system. A modification of the existing fire alarm system may be required. The UL listed spray booth is not approved for use until the fire suppression system is installed and tested. X 8) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 9) The applicant understands that they must contact the Olympic Region Clean Air Agency for a permit to operate and annual registration. X 10) All approved plans are required to be on-site for inspection purposes. If inspection is called for and plans are not on site, Approval WILL NOT be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by the Mason County Building Department prior to any further inspections being performed or approvals granted. X 11) PURSUANT TO INTERNATIONAL CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE INTERNATIONAL CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS. X 12) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X COM2005-00135 Page 3 of 5 13) Shaft penetration for the exhaust system shall maintaine one-hour fire resistive construction. • X 14) Recyclable materials & Solid Waste Storage: Space shall be provided for the storage of recycled materials and solid waste. The storage area shall be designed to meet the needs of the occupancy, efficiency of pick-up, and shall be available to occupants and haulers.X 15) Welding, cutting and similar spark-producing operations shall not be conducted in or adjacent to spray areas or dipping or coating operations unless precautions have been taken to provide safety. Conspicuous signs with the following warning shall be posted in the vicinity of spraying area, dipping operations and paint storage: NO WELDING THE USE OF WELDING OR CUTTING EQUIPMENT IN OR NEAR THIS AREA IS DANGEROUS BECAUSE OF FIRE AND EXPLOSION HAZARDS. WELDING AND CUTTING SHALL BE DONE ONLY UNDER THE SUPERVISION OF THE PERSON IN CHARGE. X 16) A new natural gas heater installed per 2003 International Mechanical Code is approved with a thermostat that limits heat to 44 degrees fahrenheit or less. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: DATE: COM2005-00135 Page 4 of 5 s C� o m N CONCRETE MECHANICAL MANUFACTURED HOME T Footings I Setbacks Date By Ribbons m Gas Piping &p Interior Date By Interior-Date „ z3 jo6, BytAt_ Date By IT!Exterior Date By Exterior-Dater ( By Set-up D INSULATION c Point toad I Isolated Footings Date By BG J SLAB INSULATION Date By Data By FIRE DEPARTMENT 0 Foundation Walls Floors Date By Date By Data By DECKS FRAMING Wails Date By Date By Data By PROPANE TANKS PLUMBING Vault Date By Date By OTHER Groundwork Attic Data By Date By Type: Date By DRYWALL n D.W.V Type:Int Brace Wall Date By Date By Date BY O Water tine Fire Separation FINAL INSPECTION c I �y r '/� o Date By Date By Dats� Ii16, Bye-.v�ll o Pass or Request Inspect. Type of Insp. Fail Date Date Done By Comments Los ' i ar 4s3 Z/ D� � -Ztt3 dto lr6D�L 14 r 00 (_&C& &f r;ac- 1. c OH tam 6r" . Nil aT r a is rn L0� h-le-I 4 1 LIC L1 L �r I . Sys��'�) dd 241 r � 7a hol MCD U1 0 COM;��Y►� -C�C?I �S MASON COUNTY CHANGE IN TENANT APPLICATION Complete the Change in Tenant Application and return with a floor plan,site plan,septic pumper's report,septic records and fee to the Mason County Permit Center, P.O. Box 186, Shelton,WA 98584. Evaluation of the Change in Tenant Application will involve staff members from the Building, Fire Marshal, Environmental Health, Planning and Public Works offices who will identify compliance requirements. This application is intended for tenant change only. If construction or remodelinq is proposed or required a building permit will be necessary. Upon approval the permit will be issued to the applicant/tenant. After the permit is issued, schedule an inspection by calling (360)427-7262. Upon satisfactory inspection a Certificate of Occupancy will be issued and must be posted in a cons icuous Qlace on the remises. Date: Assessor's Parcel Number: Legal Description:^/Cc I AIW I C7_/a i u/,1 ,A/ G WWi1 Building Site Address: /3g /3£'SS -SAf�LT ,c! /A/ ,r Method of sewage disposal: Septic Z / ,,16 O Sewer-name of district: Water source. Individual Welle)Q5i O Community Well O Public System, name of system: PEOPLE INVOLVED IN THE PROJECT Name of Applicant: G}L� Mailing address: 716E, City:� jZc-L�o�/ State: t,, A . Zip: qg_I�Ry Day phone: p-'t.32. - ,A,51 Contact Person: Message phone: 4 -N l PROJECT INFORMATION Proposed business name: M� Proposed use: �� � .S Number of employees:2a�,,,��s- Previous business name: Describe previous use: $io oG' .4-n!T c.cA-C4-'25 `e74Z, m� Check one: O Detached single level/single tenant O Single level/ multi tenant O Multi level/single tenant O Multi level/multi tenant Age of st cture: Is structure currently If not occupied, how long has it been vacant? l0 occupied? (1:e:`sj No Yr. Mo. Squar I First: 375E) Mezzanine: Second: Third: _ Is the structure heated? Heating type: Circle one: �t/o ,� b,c-ice • �45 Circle one: es No Electric Liquid Propane NaturalGas Oil CC.EGT,elC A447- Type of he; : Circle one: Furnace Heat Pump Electric baseboard o wall mount Radiant AW F'4iLrr_B&DT14 Will there be any changes to the following? Circle yes orno, if applicable: Floor lay-out: Yes N Lighting: Yes No Heating: Yes o Exterior Finishes: es No Interior Finishes: Yes No Parking: Yes Number of restrooms provided: Number of fixtures in each S,/.r K F,"Ta,(e-r Is structure handicap accessible? Circle one es No Is the structure equipped with afire sprinkler system? Yes o) Fire alarm system? Yes No Monitoring Station Name:K/o1�Cll,G7�E7<H� Phone number:&/�/I A-YTAsS 1. Floor Plan(5 sets): • Draw the floor plan to scale 0 Use of rooms • Room Dimensions • Location of all exits and windows (include dimensions) • Location of plumbing and mechanical fixtures • Interior doors with swing radius 2. Site Plan(5 sets): Note scale used • Property lines, easements, &right of ways • Location of all existing structures&dimensions • Distance, in feet,from property line&structures • Landscape buffer yards • On-site sewage tanks and drain fields, & reserve • Well location • Location of fire hydrants&vehicle access roads • Parkin areas number&arrangement) 3. Septic records,pumper's report or O&M report. OA0 /TS 7;4�kj 4. Fees will be collected at time of submittal 7WAccepted by Date Submittal Amount$ Receipt number Department Review Initials Date Comments Building Environmental Health Fire Marshal Planning Public Works Occupancy Change? (circle one) Yes No Type of construction Occupancy classification change from to S Occupant load calculated: 40 persons Existing occupant load design persons. Land Use Designation: Occupancy Classification: :51 Cn��y�o0 - �L�N v 7 7q. �i if EXISTING STRUCTURES TABLE 3410.7 SUMMARY SHEET—BUILDING CODE Existing occupancy, (% Proposed occupancy AuTo M Year building was constructed ?CC-) Number of stories Height in feet 1 �P19C5 M s e-C�- � Area per floor 3 7a O q Type of construction i Percentage of open perimeter r Q q % Percentage of height reduction % Completely suppressed: Yes No Corridor wall rating Compartmentation: Yes No Required door closers: Yes No Fire-resistance rating of vertical opening enclosures Type of HVAC system NSA serving number of floors ADeHCD Automatic fire detection: Yes -&—No type and/location \(J 9Rr-L' e&Q4 r t5 Fire alarm system: Yes X No , type Smoke control: Yes _ No type Adequate exit routes: Yes No Dead ends: Yes No Maximum exit access travel distance •t D -I �[ Elevator controls: Yes No Means of egress emergency lighting: Yes -X--No Mixed occupancies: Yes No SAFETY PARAMETERS FIRE SAFETY(FS) MEANS OF EGRESS(ME) GENERAL SAFETY(GS) 3410.6.1 Building Height 3410.6.2 Building Area 3410.6.3 Com artmentation 3410.6.4 Tenant and Dwelling Unit Separations 3410.6.5 Corridor Walls 3410.6.6 Vertical Openings 3410.6.7 HVAC Systems 3410.6.8 Automatic Fire Detection 3410.6.9 Fire Alarm System 3410.6.10 Smoke control *► 3410.6.11 Means of Egress 3410.6.12 Dead ends 3410.6.13 Maximum Exit Access Travel Distance 3410.6.14 Elevator Control 3410.6.15 Means of Egress Emergency Lighting 3410.6.16 Mixed Occupancies 3410.6.17 Automatic Sprinklers +2= 3410.6.18 Incidental Use Building score—total value ****No applicable value to be inserted. TABLE 3410.9 EVALUATION FORMULASa FORMULA T.3409.7 T.3409.8 SCORE PASS FAIL FS-MFS>—0 (FS) — (MFS)= ME-MME z 0 (ME) — (MME)_ GS-MGS z 0 (GS) — (MGS)_ a. FS=Fite Safety MFS=Mandatory Fire Safety ME=Means of Egress MME=Mandatory Means of Egress GS=General Safety MGS=Mandatory General Safety 578 2003 INTERNATIONAL BUILDING CODE® 6/2/2008 Conditions Associated With 11:22:03AM Case #: COM2005-00135 Permit Condition Status Updated item# Code Title Status Changed By Tag Date By 14) 5710 SOLID WASTE STORAGE NOT MET 12/16/2005 DLC Recyclable materials&Solid Waste Storage: Space shall be provided for the storage of recycled materials and solid waste. The storage area shall be designed to meet the needs of the occupancy,efficiency of pick-up,and shall be available to occupants and haulers.X 15) 1 WELDING WARNING SIGNS NOT MET 1/27/2006 DLC Welding,cutting and similar spark-producing operations shall not be conducted in or adjacent to spray areas or dipping or coating operations unless precautions have been taken to provide safety. Conspicuous signs with the following warning shall be posted in the vicinity of spraying area,dipping operations and paint storage: NO WELDING THE USE OF WELDING OR CUTTING EQUIPMENT IN OR NEAR THIS AREA IS DANGEROUS BECAUSE OF FIRE AND EXPLOSION HAZARDS. WELDING AND CUTTING SHALL BE DONE ONLY UNDER THE SUPERVISION OF THE PERSON IN CHARGE. X 16) 1 HEATER IN SEMI-HEATED SPACE NOT MET 5/14/2008 DLC A new natural gas heater installed per 2003 International Mechanical Code is approved with a thermostat that limits heat to 44 de ees fahrenheit or less. X Page 3 of 3 CaseConditions..rpt _ a/vu I f'1 L-n.L r WASHINGTON.vEXCE Is TOGETHER WITH ANC ® Lor I COMMERCIAL .T 22,413 SF.lsjMllA �� a ful ' " E ®� I�ctGg'� �'G �SLbcxrftaJ: ,� �L-E LAI M Fa1R gEcURr 4 co I■ 381642 COMMERCIAL ,Ll OUILDI SWIMS f l/ W EXISr/NG • I qsP ►�// fu EASEMENT OF VARYING W S 1 /// WIDTH FOR INGRESS, EGRESS, DRAINAGE AND UTILITIES (PRIVATE) �o 144.01 N j 89'11'00yl�//203/ �82./ / L Z L2 �`//� C3 S 89'11'00" E TOIL CONTROL L4 IsEPARATOR—_yam Cl •= *5 IRON BAR M=LASTIC I HOUSE z YELLOW CAP SET' O= 05 IRON BAR W/PLASTIC CAP FROt1 PREVIOUS SURVEY-, _ UNLESS OTHERWISE NOTED DRAINFIELD AREA i (APPROXIMATE) 0 = SOIL Las HOLE // ♦ = INSPECTION LID (SEPTIC) / 155 AC. \\ Co= CLEAN-OUT (SEPTIC) CtXrRr—IAL ]vtr WELL = Fx/srING wIELL PER —W— = EXISTING WATERLINE SEC' 1 WELL — IS" CULVERT SHOT SUCE RAY WATERS N M= = EXISTING CATCH BASIN EXC? EXISTING ROOF DRAIN FUTU / 300 \ / SOUTH LINE NE 114, NW 114 THIS AG1U1 LOT' S 874759" E 263.50 ORC WATE TO F 322e TOT,, VOLT WATT E SCALE. 1 =60 FEET BEL, LOT 0 30 60 120 Mason County Dept. of Community Development Mason County Bldg. 3 426 W. Cedar rioP.O. Box 186 (360) 427-9670 Local (360) 482-5269 Elma Shelton, WA 98584 (360) 275-4467 Belfair Notice to Obtain Final Inspection November 20, 2007 EXTREME AUTO 1383 SHELTON SPRINGS RD. SHELTON WA 98584-8759 Case No.: COM2005-00135 Parcel No.: 420122190102 Protect Description: CHANGE OF TENANT FROM CLASSIC AUTO/RV STORAGE TO COLLISION REPAIR & INSTALL SPRAY PAINT BOOTH The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Building Code or the code your permit was issued and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from the date of this letter. Failure to contact our office to make the necessary scheduled inspections will result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $64.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you will be charged $64.00 again, per inspection until final inspection and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 359. Sincerely, Terry Ryan Mason County Department of Community Development Cc: Property File November 20, 2007 COM2005-00135 Mason County Dept. of Community Development Mason County Bldg. 3 426 W. Cedar rioP.O. Box 186 (360)427-9670 Local (360) 482-5269 Elma Shelton, WA 98584 (360) 275-4467 Belfair Notice to Obtain Final Inspection November 09, 2007 EXTREME AUTO 71 E VANCE CT z cT SHELTON WA 98584 Case No.: COM2005-00135 Parcel No.- 420122190102 Proiect Description: CHANGE OF TENANT FROM CLASSIC AUTO/RV STORAGE TO COLLISION REPAIR & INSTALL SPRAY PAINT BOOTH The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Building Code and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from the date of this letter. Failure to contact our office to make the necessary scheduled inspections will result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $64.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you will be charged $64.00 aqain, per inspection Until fin?! ins.ecti„n and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 359. Sincerely, Terry Ryan Mason County Department of Community Development Cc: Property File November 09, 2007 COM2005-00135 FILE COPY 11'� Documents attached to approved plans: APPROVED Site plan: Plan review checklist: &4 Pages MASON BUILDING INSPECTOR Engineering: Y(:ffl Lateral Vertical CHANGES SUBJECT TO�AP_P/R�O/VA,L, � Number of pages DATE .--1—s—�—� Aolde�ol Urr-7 �or� ,,q 005-�i�� Ors I' );Ke m�mfis, �xfr�rrr� �v To 2oOs-- 001 p p MUST MEET ALL CURRENT CHANGES THE. &. PLANS FAUSTSE O WASHINGTON STATE CODES SUBMIT CHANGES FOR APPROVAL 7O Ti ���� SITE: PRIOR TO PERFORMING WORK CDR INSPEcCTIOi'! 2.4 6 feet I 2 foot I �a f ` �BeIam Span Roofing Material Tar Paper Metal Flashing Upper Roof Line 44 16 feet 6 foot S-t►'�G+vYei 44 16 feet UpFor-f-i r�c� 44 8 feet ax 4x4 8 feet 3/4'Plywood Sheets S'x4' / (I Or c k o-,Y►04, -tb 60/( 10 'J'(J 'D Back wall is excisting building 5e,e se! Su oYA n) now Fie id Co r. ,,J -) hips Concrete slab 16'x4'x14"thick �S r v f �e Concrete Compression mounting hardware CO L)Y-k T� �Yl Sf 7e�} t ., y'xof�l - Per de-fall S 5Ubrtwt:4470 ` �t11 Fast� -�`I �� . 15 , e� P�-acjP.YI cl fJn'1 0��S de dv✓i n 0� i fl5�}-i d n co Zaos- 0 U O r EX6T.SIPNS \ N EXR4T.W4i SF1T6 O N1'rE. o EA5T.29 SW a 24'HAJf. RA`rER BEW1.CZL"14ZE AND TFfIRS cJN+ crLCN � FETAL FLASWU6 ARE&N' OR TK FCLtQKY6 ` r.,. VMTKA1 LOAD. U V2'058 RWF 50tT6 W dd s6'C/ R40F SHTG 70 LBDMR"UFG SGN7L ROOF DL•a P5P OV T1LF RonFJ .. AT Ail`JIPPWTFD PAM!EXE5 Wo-4bG yq4 .8 p� � NIR Rf R-OPE PER Le(,144T AF,D 0d a b'a pe JaD ww EVOR.RF G,60 FV%,U<L 'r1 OR LCY,�L 1FU501GT70R RLLJfIFYa HATF1ilAL FSR LEOG(R SIZE 5E15MIG,ZONt 3.50tL TYFE-3,1.1 / \ ]XB MR (vla Dlsr ro 5L06) W i6''x ]XVJ FnR OR?XI]'ft0-16'G15T TO 13LDG) U �ELXJQN5 / \ 2Xi2 XC t OR 2441 ER 20,D157 TO MDG) RAFTER VMS (DF#2) a 61ry FCC AT BEARP6 IZE 174TVCE 10 BALDIIi3 ,p / LJ=D632 TO F1LH WILL STIR INLIF6• i•1 0'-f0' K!Ib' 16'X)' N aJfrEMR(TTF) \�/ MTLDSPAGll1(�` L BE 24,x Hirt J 1 %16d STAGGER(bla PST TO BLDW 17'0G 2 X b 2 X 6 2 x 10 y,F7���2_r RAFTER a {4J-{6d STAGGER QO-W'015T r0 BLD6) Y Ib'a 2%b 7 X ID 2 X I2 J J 1 {9-Ibd 5TA66F32 Ab-]CY DIS7 TO BLDS) �c ]<'Q; --TX 8 2 X 12 ]X N m FLRR)G/JE CLIP AT FA M OF RAP" Lt FETAL KAWAR � 51FP50N FU OR EaLAI. 94-I0N LSf� Uxb RAMW 9"'CH LSYr26 ao RAFFE4J BEAM SIE5 (DFtt� ' 5RPSGF L 55U210(2XL'JF LP RAFTER)CS 2}iAX BEAK Gf12-Sa MM Ealk DISTAN:E TO 910.D.)u a-IU ID-16' W-]D' FETAL POST GAP 5' 4 X 4 4 x 6 4 X 6 SF-SON AG4(4X4 czLL.F4(I b' 4 X 6 4 X 6 4 X 6 571'P5aN Aa/4xb C.G"OR $ 1' 4 X 6 4 X 0 4 X 0 E,G OL O 6' 4X6 4 X 0 4xRO z 1 L 4X0 4x[0 CGUl 4x10 n 12 FWI P �1.�?REaTcD r' 4 X F0 4 X 12 O is F� 4X4(0-10'06T TO RDSJ 4 x 6 4X6(60-W D15T.T0 BLC6) .b 4X6(&XT 015T 70 U DS) r�m1 li 8�M fiAM ]' �C l n A SPAY— —LPIJiFWi I ►r � LGrPfABLL FETAL P05T BA E(6AVANVEDJ Y—L T S+r+F•�a+L4844(4x4 COLIFW � DurAlY.t SUPSGN l.GE346(4X6 COtiFeU GA TO&.Dd- FOOTDO 4 f�UL N GOLlta!R'TPl C:A4 fiYPJ 7CLR L,ry 6'FUR 3 {TT'P1 ALGIFfaigLl! BUtLL!NS f4,LPl P P{8N my L AhAY���m (.OFGRETE POpT1Ni 1 4'N.41 N L H 3•uR +c_��w "��' 57ANDARD DETAIL FOR ATTACHED rn PJ 2 44 EA eur rcv.ear LATER ry•P57Ah"70 b-D6. RE51VENT IAL CARPORT Y SO FTC, 3'C R SECT IOC\ FLAN 14-0.0.OLYMPIC PENINS(,CA G}G4P'TER fryp) Cv✓e D-eAni/ Nf5 IlTS rI 5GALE I DATI• I DR 6'r I -i? NO ICY16 N7 X'MP 3,3l1946 • O O A7 Th'S'PLANS F.tjLiST Bc Aid e4ldo►'1 C IN Tf-i E jr o f S t c Cp nil Z005-001 F(,r? jrvspEc rjoiv 7 MUST MEET ALL CURRENT vNSTATEC�vT WASHINGTON STATE CODES ES 77 f l� r s'� CHANGES Rem row !-,'fin v SUBMIT CHANGES FOR APPROVALd o5 6,0 PRIOR TO PERFORMING WORK 6m VG 97, �i CHANGES wgUsrMEFr ,. �. SH`NG qCC SUBMIT CNANOES FOR C A T AP PROVAL P R 0 Q R V PR IOR A R l r R TO PERFORMING NsTgrEco lvr S ` .. , FWD, $Y �5f ?is I 1 � xa j4 Case Activity Listing 5/12/2008 8:19:24AM Case#: COM2005-00135 i Assigned Done Activity Description Date I Date 2 Date 3 Hold Disp To By Updated Updated By COMC100 Inspection 2/21/2006 2/23/2006 None COND LDK 2/24/2006 KLW GAS PIPING PASS,HEATER PASS COND,NEED LOCKOUT BY FINAL ALSO NEED TO ADD COMPRESSOR LOWER AT REAR TO T.I.CONTACT DEBRA COMA985 LTR-Notice Final Inspection 11/9/2007 None DONE TFR 11/9/2007 TFR COMA985 LTR-Notice Final Inspection 11/20/2007 1None DONE TFR 11/20/2007 TFR COMC157 Final Inspection-Failed 12/11/2007 12/13/2007 None FAIL LDK 12/14/2007 KDM 1-.PROVIDE FIRE MARSHAL SIGN-OFF OF FINAL 2)STORAGE AREA PER PI AIV TO BE 1 HR RETED-HOLE IN CEILING WILL NOT BE ALLOWED OR MUST BE RATED 1 HR OPENING.FRAME OPENING AND DRYWALL CEILING WITH 5/8 DRYWALL AND TAPE AND MUD 3 PER PREVIOUS INSPECTION FOR UNIT HEATER-CONDITION CALL FOR LOCK-OUT TSTAT AT 44 D re.✓i�r�/eG� OUND NO VISION ON PLAN SHOWING AIR COMP SSOR STRUCTURE ON REAR OF BUILDING UBMIT REVISIONM COUNTY FOR REVIEW s'v eG e I 5) VE MARSHALL O 3P40 OFF ER f CA **MAKE CORRECTIONS,ITEMS WILL BE CHECKED ON NEXT INSPECTION**** CO Y�C-H6 n S COMC260 Fire Marshal Final 4/11/2008 None PASS CJH 4/14/2008 KDM PIONEER FIRE AND SECURITY WILL RELATCH SEVERAL HEAT DETECTORS UTILIZING A HYDRAULIC LIFT.ALL FIRE EXTINGUISHERS,SPRAY BOOTH SUPPRESSION SYSTEM AND ALARM SYSTEM ARE CURRENT ON REQUIRED INSPECTIONS,(SEE ATTACHED) COMC157 Final Inspection-Failed 4/8/2008 4/15/2008 None FAIL LAW 4/16/2008 KDM EMPLOYEE ONSITE SAID THAT THE INSPECTION WAS CANCELLED YESTERDAY.NO INSPECTION DONE. TV-E,';E PLANS MUST 13E • n E 10_'vITE t A Go„1 Z�s-oo13s Page 2 of 2 / / ' Al U C_'C ivity..rpt EXISTING BUILDING PAINT BOOTH 3'HOLE IN ROOF FOR 75, Es -14 EXHAUST ' / �_ BOOTH FIRE = EXHAUST FANS 3'MAN DOOR SUPPRESSION ALARM ~a S ELECTIRCAL N CONNECTION 3 ���� 6, z AIR n C❑NNECTI❑N x B 50 141 PAINT BOOTH DOORS `-- PAINT BOOTH DOORS ❑ EXISTING ru N S = STORAGE ROOM PAINT BOOTH CONSTRUCTED B = BATHROOM OF GALVANIZED STEEL �3 DOOR IL8' 1 ,8' w ❑ = ❑FFICE SPACE d \ BAY DOORS o EACH C❑NTAINS SCALE 1'= 20' 3' EXHAUST PORT I ✓ \R/ ROOF DRAIN CONCRETE SLAB FLOOR ROOF DRAIN �\ 6" DIAM. PVC 4" DIAM. PVC SCHEDULE 80 SCHEDULE 80 I.E. 268.61 1.E.269.12Iq �9 50' z 240 36 Iq CA TCPI,k3A SIN #1 W i ' R 7'YPE 30 RIM ELEV. 2`zi t29 '� f \` 55 �` I.E. OUT 269.8.7 X 27 °'o DFH581C o �,' ` �qM p o �� ► CATCH BASIN #3 of �� i TYPE 1 SC ' RIM ELEV. 271.09 11�9 ``` C '9 8 \�� i `lD� I.E. CB #1 `"1121'`' & #2 269.54 U*) ------------t----------�' � 6.0' I.E. OUT 269.40 - ROOF DRAIN ^ ROOF DRAIN , p� I.E. 268.25 0 I.E. 268.75�, CATCH BASIN #2 ,�'v0 SO� r� TYPE,30 �M. P 0� F o A RIM ELEV. 271.7.9 I.E. OUT 269.87- Lo ROOF DRAIN I.E. 267.88 �1:'' 21� ? \` lo o -0.0095 FT. GRADE OOF RAIN 4'R DIIAMD PVC 4 EXISTING CATCH BASIN SCHEDULE 80 RIM ELEV. 269.14 I.E. 268.39 Q NEW I.E. IN NORTH 268.30 00 ,n ;O -\ROOFIDRAIN "DIAM. PVC I 1s SCHE E 80 rn I.E. 267.50 • D BUILDING #1 BLOW UP NOT TO SCALE December 6, 2005 r TO: MASON COUNTY PERMIT ASSISTANCE CENTER FROM: EXTREME AUTO BODY GARY YANDO—PERMIT CONSULTANT SUBJECT: CHANGE OF TENANT APPLICATION You will find attached a Change of Tenant Application being submitted by Gary Yando for Jim Ness of Extreme Auto Body. Mr. Ness is proposing to change the use of the existing building located on Shelton Springs Road. The existing building has been used for the past four years for repairing vehicles and also for the storage of antique vehicles and recreational vehicles. It is Mr. Ness's intent to use the building for auto body repair work. You will find attached five copies of the required application, a layout of the building and the paint booth location. In addition, you will find a blow up of the existing building and a drawing that shows the locations of the drainage facilities that are already in place. I might add that there is an approved Stormwater and Erosion and Sediment Control Site Plan for the site. There will be no additional impact as a result of the proposed use. You will find enclosed a check in the amount of$127.00(as required by staff). We are requesting that the necessary steps be taken to process this application in a timely manner. If you have any questions, please call either Jim Ness or myself. S" rely, d N Y ,�, �. .,� � -,: ` � .,,� ,�_�• .ter • ,„�,. . - . wi T s.. t