Loading...
HomeMy WebLinkAboutSWG2007-00354 - SWG Application / Design - 5/29/2007 ONSITE SEWAGE SYSTEM APPLICATION 1 . w v� y D MA is ALTu Official use onl��,t/_. �pCEI.�p�.CEDIR EET PERMIT NUMBER: S v -�`•� SPICIVA 98584 DATE RECEIVED: �7AMOUm RECEP/ED:S,J a G APPLICANT DATE CNECKAPPLICABLEm:NS a o NEW SYSTEM 3 0 h / p REPAIR SYSTEM O MAILING ADDRESS DAYTIME cPHONE p TABLE S REPAIR p �a5o� 1��� N •�fi3 TANK REPLACEMENT STATE ZIP 1l/ p4 p RV HOLDING TANK ONLY T Omt�\PNTJ �{�� IVO I1STALLwaiver) s yp INSTALLATION PERMR ONLY Y SITE ADDRESS A SINGLE FAMILY Z 13 tl la \a L Yv`�•'^ ^S`„� � PI...OTHER 3 0 NAME OF DESIGNER PHONE NUMBER Nola � "'r' �a .�, Aabuiln requiredlor aQ inshllo4onc z ` NAME OF INSTALLER DRINKING WATER SOURCE IU, PRIVATE INDIVIDUAL WELL PRIVATE Iu NUMBER OF BEDROOMS LOT SIZE: ACRES FT X FT D PRIVATE TWO-PARTY WELL l^1 p OOMMUNmIPUSLIC WATER SYSTEM I I" SYSTEM WFI# I W 1t\`�� } SYSTEM NAME: I. SPECIFIC DIRECTIONS FOR LOCATING SRE. 0 IU x Site must be flagged from main road and test holes must be flagged with test hole numbers I b o ID Official use only below this tine I I SOIL LOGS C0MMEMS/C0NDrF10NS SOILTE7 CODES: V = G• revel S=send L-b SI-SR Cmday E_ R SIGNATURE DATE DESIGNEXPMATIONDATE DESIGN APPROVED BY DATE (1/7/07 2 / 6 to 07 DATE A`STALLATI FEE PAID INSTALLATION EXPW.TION DATE TALLA ON PROVED BY DATE Z!o 07 Revised anrzam MASON COUNTY DEPARTMENT OF HEALTH SERVICES hi- June 10, 2007 Robs Excavating 1871 E John's Prairie Rd Shelton WA 98584 RE: Design for BREEDEN Case No: SWG2007-00354 Parcel No: 322345000014 Your design for the above referenced parcel has been review and is APPROVED. Please refer to the comments section of this letter for any additional information. Please call me at (360)427-9670, ext. 279 if you have any questions. Sincerely, ',/�,/,��,'/� Amanda Environmental Health Mason County Health Services COMMENTS: 6/10/2007 1 of 1 SWG2007-00354 DESIGN FORM-PAGE ONE+A desiga will be reAewed whn 3.vieof anaeh of th e folwD6�Y, Completed dceigs firm thin haz been siged d dazed si(}rrooLf skVetcE D ing erg epplimble items on d ckli.R +SWeA plot plea ivcluduag all applicable items on checklist +C. including au eppErable Dams on eh"^Hn� MadmRRR 11'X 17" Pemvt Number. SWG CU7 -pU� ].t Deslgoer's Name: ' Applicant's Name: Aa (llyrljgnl Designer's Phone Numbs: Mailing Address: 10SCiS 1\9�. 'P N E Demper's Add ess: Z. rn N k 'Rt. gj ly City So e Zip qn. Stale � N� v aA v AesessoegPWWNumber:. IDD2, -5g. -s"41 TreabacitDev4x . ❑Glendon N.M. ❑Sand Filter ❑Moned ❑Si 1 I,ioN DnmSeJd ❑R inntjnotZ Fdn,,Type:_' ❑Aerobic Unit Mabe Model ❑Doiinteon.Una MakNModal Oche. Drainfield Type - - ❑GmAty ❑Pseasee .O Trench ❑Bed 0 Sub,SWARD Drip Septic TaeWDrsuBdd$pa7Lcations lAftmk Number ofBed[ooms '� Clan - DnilyFlnav - ■�f+PPROV.- xf zap— ft %Js Septic Tank Capacity � � DianivW HEALTH 0EpT j1.� q m - Rooming Soil TypeG� _ Number ,iUN I 0 2007 . Receiving Soil Appl.Rate fe gpd/ Seaman e.Z ft Resigned Square Footage- Su o fe qp� � - Designed Squna Footage SO ftf ianl Ni®b!i ofOri6wa Percent Reduction Takm O % Dinrheter 5II(e in Itencb/Bed WMth �10j--- ft ypoomg. .3(P— in Tsencb/Bed length 'il ft Manifold Elevation Memmunna ob hc�'Clau �t Origmel Dreinfield Ate Slope Q Yo Length .New Slope.HAlraed _ Q % Diameter p1 �{t n Depth ofmW Gole Nn+iwe) A! inRefemd manifold wnBSvadm aed7 OYa No Trom Origiml Grade ��-ayal :al in 1Yaesporl Pipe Desigped Vertical Seperetioa in ye�lass . Gmnllea Chambers Rqueed? 0 Ya 13 Optimal Length ft Pump Requhed? XYce ❑No Dinette a, in Pmm�BWw SpeciScatiova Dosing and Pnm DOn��ce in Elevation etweenm Pump 56umfiand Uppam.t Numb es/day Dos PI Uppermost Orifice Higher G Lower thm pump Shutoff �Qa� By Capacity @total Ptessme Head 3<.'l a(in)Elapse T'me Mete Cf k rjrerpb d Calculazed Total Pressme Hmd 9'Z(0 Pump off comments 5Pyo LjWR. O WINE IGN.q... DESIGN FORM—PAGE TWO Assessor's Pascal Number:3 a a 3`I — 51 — .Q a QA Pewit Number. SWG Scaled Plot Plan Scaled Layout Sketch Cros"ection Sketch Test hole locations Dtainfield orientation and layout Reference depth from original grade: b Soil logs V Trench/bed dimensions and \� Septic tank Property lines critical distances within layout k7 Drainfield cover Existing and proposed wells �9 D-BoxfValve box locations Reference depth from original grade within 100 R of property 'Q Septic tank/pump chamber anrestrictive strata: Measurements to cuts,banks,and locations 10 Laterals,trenchftwd,top and surface water and critical areas b Observation port location bottom Location and orientation of b Clean-out location ❑ Curtain drain collector curtain drain and all absorption b Manifold placement ❑ Sand augmentation !i components �3 Orifice placement r cross-section detail: )] Location and dimension of Lateral placement with distance Observation portstcleanouts I primary system and reserve area to edge of bed Other Information Buildings Audiblelvisual alarm referenced Yes No Direction of slope indicator Scale of drawing shown on scale ❑Design staked out Waterlines bar ❑ ❑Recorded Notices attached Roads,easements,driveways, ❑ ❑Waiver(s)attached parking ❑Pump curve attached MNorth arrow and scale drawing ❑ El Evaluation of failure shown on scale bar Non-residential justification ❑ ❑Waste strength ❑ ❑Flow The undersigned desi er does not,waive the requirement to be notified by the installer at time of installation. {� \�- 5--a3 -o� Signature of Designer Date The undersigned has reviewed this design on behalf of Mason County Department of Health Services and determined it to be in compliance with state al on-site regulations: / 07 Environmental Hcaltfi Specialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDTITON: The design is stamped"Approved"by Masora County Deparment of Health Services. / The Onsue Sewage Permit has not expired,the Permit Expiration Date is: J 201,0 Drsinfteld site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer,unless prio from Mason County Department of Health Services.An Installation Permit is evi 06 100 72 'p; T GDODN ... E1lPIRES 0808-C1_. 491 U� ji SCxalx, 1'_ ao s a' T s ,WJPPRO p h' 1 01007 PT 4oq µlM1YW N7}� WAS • . ...` �oi W/cd+'C.oa ff\o 'VbT7��t,.� SNet,�'k}„� $.. Fe'y^F pT v �01 1` IeS� `011A�YL Ib 100 T N rMw 1Va1 T.I...i EXPIRES 08-D& p, �aaay - 50 - 000��{ .pa�u.r a fAS MAPPRO AED Uv r 0 2007 epT AIR \o a' a' a' o = o6sccwA1 �A 100172 OBERT GOOOMN'�. L EN I NEF EXPIRES 08-08-p"� �R.aa �k �aAec� MAPPRO QED pr 1uh i 0 2007 AOR, e C� 11 11 I�11 � u 100172 m S ......BE. RTGOODWIR'". �.1 EXPIRES 08-08-Cr-/ SECURED LID WITH GAB TIGHT BEAL 24'DIAMETER 1 AOCm RISER FINISH GRADE TO PUMP CHAMBER FROM SEWAGE SOURCE FIAATiNO MAT APPROVED EFFLUENT FILTER SEDIMENTIS MAPPRo QED SEPTIC TANK JUN 2 0.2007•.:'.. '. - f7YPoCALI AD,R • . SECURED LID WITH OAS TIGHT SEAL THREADED UNION 24•DIAMETER ACCESS RISER - FIHISN GRADE TO DRAINFlEID FROM SEPTIC TANK EMERGENCY STORAGE HIGH WATER ALARM LEVEL INDEPENDENT WORKINGVOLUME FLOAT STEM VJI AJJI D�1. VI�J4L FORFLMT— — — MOUNTING 16N a 3hn CMEOK VALVE 6USMERSIBLE SEDIMENTS CENTRIFUGAL PUMP ' PUMPCHAMBER (TYPICALI ' All NEEDED SE SKHD150 SP40 SP50 ��. MAX-SOLIDS 3/4"SPHERE MAX.SOLIDS I-1/4"SPHERE MAX.SOLIDS I-1/2"SPHERI 1-1/2 HP - 4/10 HP 1/2 HIS 3450 RPM - 1750 RPM 1750 RPM MAPpRo 4ED ,c�>u w Apr t • Dual shaft seals Mand aa{.,u'�"F. • Available in automatic and manual • Available in automatic and manual failure sensor capabiirty ava}jaWg `�i • Oil-filled ball bearing motor • Oil-filled,heavy-duty ball bearing Ito be wired to an alarm devmek ° incorporates automatic reset motor • 1-1/2 HP,oil-tilled motor thermal overload • Enclosed.two-vane cast iron • flogged east non eonatrocnon • Non-clog,two-vane thermoplastic sewage-type impeller • 1.1/2"NPT discharge:- sewage-type impeller • Automatics feature oil-isolated • Spring loaded mechanicotseah • Automatics feature reliable level control diaphragm switch in with carbon and ceramic feces-"' "'' diaphragm switch with piggyback cast iron housing • Non-clogging semi-open - plug-in • Rugged cast iron construction thermoplastic impeller a-s_ • 2" NPT discharge • Mechanical shaft seal with carbon • Pump-cut vanes on rear shroutt'ef T. a Rugged cast iron construction and ceramic faces impeller ,`' • Stainless steel shaft • 2"NPT discharge(3"flange • For high hoed septic tank fftuenY^° • Completely field serviceable optional) applications • Residential sewage ejector or high • Completely field serviceable 01-1/2 HP, 1 a 230V and 3020OV:.'.`r capacity sump pump • All bronze modal lSP50AB1)in 230V,460V or 575V • 4/10 HP, to I I SV or 230V automatic. 10115V • 1/2 HP, to 115V,200V,230V and - - 3a 200V,230V,46DV or 575V tt• a pa �m dm ....1111u 3x 7a yz pa x m x r w x °a m a x a tx ao ap a a Se as tM It rY.1Q1YL.16YM WaarrilE alM CIV101YYSalM 1871 E Johns Prairie Road Shelton,WA 99594 360-426-6697 GENERAL NOTES 1. Rob's Excavating has designed this system in accordance with all-current state and county Health Department requirements and assumes on responsibility for its use or longevity. The ovmer therefore agrees to maintain and make all necessary repairs to the system at no cost to Rob's Excavating. 2. The contractor shall be certified and approved by the county to install septic systems. 3. The contractor shall field verify all contours, stub out elevators,and trench depths in drainfietd areas before construction- .a II construction materials and installation shall conform to all applicable state Health Department requirements. the installer's responsibility to have a copy of this design onsite at all "'�` u construction Cshell be the owner's andlor installer's responsibility to notify Rob's rating and the county Health Department for the required inspections ore backfilling. 7. All required tests shall be successfully mn before calling Rob's Excavating for final inspection All components,including all tank access lids must be accessible for inspection. 8. Rob's Excavating and the County Health Department shall fist approve any variations to this design. 9. Owmer/histaller shall not remove my topsoil in drain5eld area. Removal of topsoil could remdw the site unusable. 10.Eudsting utilities shown on the plans have been plotted from the best information available to the designer. Accuracy and completeness are not guaranteed. ROB'S EXCAVATING 1871 E JOHNS PRAIRIE RD SHELTON, WA 98584 (360.416.6697) INSTALLATION/MAINTENANCE PRESSURE DISTRIBUTION SYSTEM 1. Install laterals with contour of the ground. 2. histall trench bottoms level and at all times a minimum of six inches into the native soil. 3. Install locator tape on top of all drainfield laterals. 4. Install observation ports as indicated on the plot plan(minimum two per drainfield with bottom extending to the drain rock/native soil interface). S. Install drainfield during dry weather and soil conditions, and soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the ends of all laterals(cap must extend to within 6 inches of finished grade and be marked with locator tape). 7. Install audio/visual high water alarm. 8. Install 1/8 inch mesh non-corrosive pump screen(min. 12-sq. ft. surface area,not to interfere with controls or floats). 9. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. I 10. Filter fabric required over drain rock prior to backfilling. If the drain rock extends i above natural grade, ran the fiher fabric at least 2 inches down the trench wall. 11.Divert all storm water run-off away on-site sewage system. 12. No curtain drains allowed within 10 ft. or the up-slope edge of the drainfield and reserve area 13. No curtain drains allowed within 30 ft. of the down-slope edge of the drainfield and reserve area. 14. Have the septic tank and pump chamber pumped or inspected every three to five years. 15.Inspect floats,clean pump screen and test water alarm every 6— 12 months as needed. 1%V6. 16. All materials and workmanship must meet County and State regulations. 17. Septic tank risers to be at or above finish grade. 18. Deviation from this design without prior approval from the Designer and Mason County Health Department will make this design null and void. 19. Pump chamber lid to be above finish grade. 20. The on-site septic system owner is responsible for properly operating and maintaining the OSS and shall: a) Determine the level of solids and scum in the septic tank once every three years. b) Employ an approved pumper to remove the septage from the tank when the level of solids and scrum indicates that removal is necessary. c) Protect the OSS area and the reserve area from: 1. Cover by structures or impervious material 2. Surface drainage 3. Soil compaction by vehicular traffic or livestock 4. Damage by soil removal and grade alteration d) Keep the flow of sewage to the OSS at or below the approved design both in quantity and waste strength. 21.High strength waste will increase the depth of the biomat in a drainfield, causing a decreased flow through the biomat and possible ponding or flooding of the drainfield. High strength waste in a residence is usually related to the`9ifestyle,or habits of the home,generally resulting from one or more of the following: a) Excessive use of a garbage disposal b) Consecutive loads of laundry done all on one day c) Excessive bleach or detergents with added whiteners d) Dishwashing, showering, and laundering all at the same time e) Medications—antibiotics can kill or impair the biological process in the septic tank. t) beaky plumbing(hydraulic overloading)