Loading...
HomeMy WebLinkAboutMIS95-0412 Above Ground Diesel Tank - MIS Permit / Conditions - 6/30/1995 i MASON COUNTY PERMIT NULL & VOID BY EXPtRAT16k f ,\ Mason County Bldg, III 426 W. Cedar DATE / - P.O. Box 186 Shelton, Washington 98584 BY M 1 r-.C E L— 1_._ A N E C3 LJ S P F: F 1 " I Ira P I , 1 1 !IV; Al 1 1'-' ! •+6 !0 PL.A 1 JOB ADDRESS : W 633 DAYTON—AIRPORT RD LJK LION APPLICANT : GREG BROWN OWNER : GREG BROWN LEGAL s T1 i OF 1112 S1 PROJECT DESCRIPTION : INSTALLATION OF AN ABOVE GROUND DIESEL STORAGE TANK PROJECT LOCATIONS DOT ENTRANCE GATE PROJECT NOTESs TYPE AMOUNT BY DATE RECEIPT PRMT S 26 .00 TW 06/30/95 39527 STFE 4 ,50 TW 06/30/95 39527 ( _ TOTALS 29 .50 yl OWNER OR AGENT DATE 11S_Fill, rev i 04111192 COMPLIANCE TO ATTACHED CONDITIONS IS RE'GU I RED CONCRETE MECHANICAL MOBILE HOME Footings-Setback date by Ribbons date by Gas Piping date b Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEPT. date by date by date by PLUMBING OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by f MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 PFERM 1 -f C- C) Nn 1 T' I (_)N �3 Case No . : MIS95.-0412 Fort GREG BROWN page ! 1 1 ) Approved per site-plan . 2) Property is IooAted within Flighly Critical Aquifer Recharge Area , applicant shall handle hazardous materials; (fuels , chemicals , pesticides ) according to state guidelines for these materials and store them as per plans submitted . 3 ) All approved plans are required to be on-site for Inspection purposes . If inspection is called for and plans are not on site, Approval WILL NOT be granted . In addition , a Re-- Inspection fee in the amount of $30 .00 per hour (minimum 1 hour ) will bA charged and must be collected by this department prior to any further Inspections being performed or approval granted . C 4 ) ALL CONSTRUCTION MUST MEET OR EXCEED AL-L LOCAL CODES AND UBC 13 QUJ REMENTS I --------- ------- CONCRETE MECHANICAL MOBILE HOME Footings-Setback date by Ribbons date by Gas Piping date b Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEPT. date by date by PLUMBING date by OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 5 ) Changes to appr caved bu i I d i ng plans- 'that et fect comp i l aiice to the 1991 Wrct: h l ngton State Energy Code, 1991 Ventilation and Indoor Air Quality Code, the Uniform Building Code and/or Mason Co ,u _ u Ions must be approved by Mason County prior to constructlo ; ,, 6) CONSTRUCTION PROCESS TO BE FIELD CORRECT -AS . UIRED PF:R MASON COUNTY BUILDING DEPARTMENT AND UNIFORM BUILDING CODE _M I 7) 1 . PROVIDE AN EMERGENCY SHUTOFF SWITCH WITHIN 75 ' BUT NO CLOSER 'THAN 15 ' TO THE TANK . 2 . PROVIDE A 2A-2013C RATED FIRE' EXTINGUISHER WITHIN 75 ' OF THE TANK . 3 . PROVIDE PROTECTIVE BOLLARDS AROUND THE TANK . CONCRETE MECHANICAL MOBILE HOME Footings-Setback date by Ribbons date by Gas Piping date b Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEPT. date by date by PLUMBING date by OTHER Groundwork date b date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by MASON COUNTY MISCELLANEOUS PERMIT APPLICATION 426 W. Cedar/P.O. Box 186, Shelton, WA 98584 - 427-9670 PLEASE PRINT #1 OwneT Phone # Fire District#— S ite Address l�3(033 �I��ccn.1-rs�rt' -T Ror+� City 5 4 PJ_-Mz Si MaAddress City St Zip Applicant Phone #,zmGl '2 t Applicant Address jai 2-1 City LEI^3"-_ ah St Lu Or zip 4edoM._ Directions to Site: 4 v" ly 3 sow aP Lia�,� - 3� �c c`c��i i1 i #2 arcel No. 20c� - - cn� I d Legal Description _12�C'C- L tl2 5Lo #3 Indicate by circling the applicable source if any water is on or adjacent to the property site: saltwater lake river creek stream pond wetland seasonal runoff marsh other #4 Project Start Date , I �,- �4 '�tS� Project Completion Date G- 3y'`�S #5 Use of Buildiing Describe proposed construction I►V 5Tt i_c_A-:ccs,J c,V- #nJ P-Qot Ye_ )Lots aa__ S'tacL -rp% S,,L CAoP*v�- 4--. B o E- L} adp E�. 0yJ0 `Depending upon the type of permit,a floor plan and plot plan may be required. 'This permit is valid for 180 days from the date of issuance. OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT I CERTIFY THAT I AM EXEMPT FROM THE REQUIRE- I CERTIFY THAT I AM A CURRENTLY REGISTERED CON- MENTS OF THE CONTRACTORS REGISTRATION LAW TRACTOR IN THE STATE OF WASHINGTON AND I AM RCW 18.27, AND AM AWARE OF THE MASON COUNTY AWARE OF THE ORDINANCE REQUIREMENTS REGULAT- ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT ING THE WORK FOR WHICH THE PERMIT IS ISSUED AND IS ISSUED AND THAT ALL WORK DONE WILL BE IN CON- ALL WORK DONE WILL BE IN CONFORMANCE THERE- FORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITH. NO CHANGES SHALL BE MADE WITHOUT FIRST WITHOUT FIRSTOBTAINING APPROVAL FROMTHE BUILD- OBTAINING APPROVAL FROM THE BUILDING DEPART- ING DEPARTMENT. MENT. X OWNER X BY yI�C !DATI DATE = (Q�( �� i i i 6 Show following on the site plan Lot Dimensions Flood Zones Existing Structures Fences Structure Setbacks Wells Water Lines Shorelines Drainage Plan Easements Septic Systems Name of Fronting Street Indicate directional by Proposed Improvements Name of Flanking Street N, S, E, W etc: PLOT PLAN AREA I FOR OFFICIALOSE ONLY:Accepted by::! fate .. DEPARTMENTAL REVIEW FOR OFFICIAL USE ONLY Planning APP COND APP HOLD b3 Building LA)"-� to-Z�1" Fire Marshal 17 W. Other Special Conditions d p �� Fees Permit Fee $ ;z Plan Check Other Other State Building Fee .50 TOTAL DUE a g N J�OJ �• - N E'il -------- - ---------- -- i/j1N7 h'6 N Z� — 1�> J✓07 i�y1S Cl1�1b — ;7,S4 - ----•---313?J71rvi�ll!1'± 77t� - - ----- - - -- ----�._ -I+.__ � 73Ndd MC7�� 071t19 vy 53�07-_Tj - „Zl �d���- ,cd g ai- .�If . i rl „ 17d Wr-w - ��lr vd n n" d��i y r J - ti r THREADED 1" PIPE CAP PUMP EM. SWITCH SIGN SITE LOCATION AND EMERGENCY PHONE N0. SIGN (FUTURE) _ = EM. PHONE (FUTURE) FIRE EXTINGUISHER SIGN FIRE EXTINGUISHER & CABINET WITH 'BREAK GLASS-TURN HANDLE TO OPEN' ^ -) VINYL DECAL (RED) I In In EM. SHUT-OFF SW. 4"0 GALV. PIPE S 2"X2"X1/8" ANGLE FRAME PAINT 'RED' EXTERIOR GLOSS ENAMEL iv ;'i I: q I CONCRETE i J 4. {F- REMOTE SWITCH SUPPORT 0' 1' 2' 3• MODIFY TO ACCOMMODATE STEPS WHEN REQUIRED F16'-6' (3000 GAL. TANK) ('Al NOTES: VERIFY SLAB SIZE WITH TANK 18'-10' (4000 GAL. TANK) ('A') DRAWING PRIOR TO CONSTRUCTION CONCRETE SLAB SHALL BE SET 0 20'-4' (5000 GAL. TANK) ('A') TRUE AND LEVEL. 23'-8' (6000 GAL, TANK) ('B') CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI -- AT 28 DAYS. #5 REBAR 0 9" LONGITUDINAL o CDDOUBLE WALL / #4 REBAR ® 9" o INNER VAULT TRANSVERSE 0- AN TANK J � J a a W GUARD POSTS EQUALLY SPACED 1 1/8"0 ANCHOR 12" ( ALL AROUND ) ® 4'-6 MAX. , � BOLTS (TYP.) MIN.' (16) REQUIRED @ FDNS A ) GUARD, POSTS (18) REQUIRED ® FDNS 'B') EQUALLY SPACED ® 4'-6 MAX. FOUNDATION PLAN (3000-4000-5000-6000 GALLON DOUBLE WALL GUARD POSTS INNER VAULT TANKS) 4" STD. PIPE (OR SIZE AS REQ'D. BY LOCAL JURISDICTION) CONCRETE FILLED & PAINTED YELLOW 3 REBAR (CONT.) T & B 6" WHERE FROST LINE OCCURS). DRAIN VALVE #3 ® 12" (WHERE FROST LINE 3" LOCATED TO SUIT OCCURS ONLY). 3" CL. " #3 REBAR (CONT.) #5 ® 9" 15" #5 ® 9" N #4 ® 9" #4 ® 9" GRADE GRADE M _ W a• . m •a ih DEEPEN EDGES / ``' co �� �� � — — o � � _ _ J DEEPEN EDGES TO TO FROST LINE j M #3 REBAR ® 12" 12" LINEFROST AS AS REQUIRED t 2" 12" " REQUIRED. CONCRETE DIA., FOOTING .� , ' TYPICAL CURB TYPICAL (When Required) GUARD POST DOUBLE WALL INNER HOOVEI � VAULT TANK CONTAINMENT SYSTEMS INC, FOUNDATION PADS C CONSTRUCTION DETAILS 5-19-93 DWFDN2 15'-0" 14'-0" 19 1/4" DIA. 12• MUSHROOM VENT 24' 13-GALLON IN TOP SPILLBO �6- -FsI- ----------------- -- -- ---�-- ----- 2,; ; 2" STD. PIPE FOR — - ---- MONITOR ACCESS. EM. 8 VENT CC) 00 4 _ 8` EMERG. VENT & I -- ACCESS OPENINGS (AS REQUIRED) `D ! FOR POURING CONCRETE -------------------_ (PVC. PLUGGED) 2 I 6" SPACE ALL AROUND TOP PLAN BETWEEN INNER AND OUTER TANKS, (TOP, BOTTOM, & SPILLBOX SIDES), FILLED WITH 2" STD. PIPE FOR CONCRETE. MONITOR AC ill CESS. SEAL WELD THREADED CONNECTION ALL OPENINGS (TYP) SEE TOP PLAN. TOP VENT SEAL WELD TANK ENCASED W/ I I I , 1/4' POLYSTYRENE—�, ' , 1 1 E CD INNER TANK 1 1 1/4" TOP,BOTTOM & 1 1 I `D ENDS-3/16" SIDES I , 1 I 1 1 I -----------------------—--------------------------------------------- OUTER TANK 1 1 3 16" ALL AROUND U OR 360° 2' 3'-0" 4'-6" C❑NTAINMENT) II 8'-1 4'-6" 3'-0" f -, 8'-4" C6 X 8.2J/ ELEVATION 1 1 4'0 HOLE HOLSUPPORTS WITH FOR ANCHOR IN EACH G. EACH END HOOVER EXTERIOR 4-CONTAINMENT SYSTEMS INC. EPDXY PAINT DESCRIPTION: 4000 GALLON SINGLE COMPARTMENT ABOVEGROUND ❑R FIBERGLASS THIS DRAWING AND THE DESIGN sHovN — 9'ss LIQUID STORAGE VAULT TANK. HEREIN IS THE PROPERTY OF HOOVER 2 JRD U/L 2085 LAB LED COATED CONTAINMENT SYSTEMS INC. BY: PATE: OWG: USE OR COPIES THEREOF CANNoi >+E JRD 5-29-93 SW4MVTT MADE VITHpUT VRITTEN CONSENT. HO NIER w 9 R Containment Systems Inc. PE�= A S UBSI DIARY OF HOOVER GROUP, INC. 410-987-3800 P.O. BOX 396 800-777-2823 SEVERNA PARK, MARYLAND 21146 FAX 410-987-3890 SPECIFICATIONS HOOVER VAULT TANK UL LISTED 2085 "PROTECTED" TANK 1.0 GENERAL TANK DESCRIPTION: 1.1 The Single Compartment, Single Wall Inner Hoover Vault Tanks are constructed in accordance with national, state, and locally recognized aboveground storage tank standards such as: The Uniform Fire Code-Articles 52 and 79 Appendix II F and Appendix Standard A-II-F, Underwriters Laboratory Standard 2085 Protected and Insulated Tanks and Standard 142 and The National Fire Protection Association Sections 30 and 30A. 1.2 The Vault Tanks are constructed as single compartment, double wall steel tanks, utilizing steel primary and secondary tanks. The primary tank is resistance to bullet penetration (per UFC Article 9 and Appendix H F). A minimum of two(2) hours of fire protection is provided (per UFC Appendix H F and Standard A-H-F and UL 2085 Protected Tanks). 1.3 The tanks have 6 inches of "light weight concrete" surrounding the primary storage tank. 1.4 The primary tank shall have a separate intermediate barrier surrounding it which provides a leak detection space void of fire protection material. 1.5 The tanks shall g have the fisting mark from Underwriters Laboratory for Standard 2085 Protected Tanks and Certification from CARB for Phase I and II Vapor Recovew. 1.6 The Anchoring tie downs shall be welded to the bottom of the secondary tank and meet Zone 4 Seismic requirements and must be off-loaded on site with a crane. 1.7 All openings shall be from the top , with threaded NPT risers. 1.8 The Tank Manufacturer shall provide certificate of insurance that provides a minimum of twenty- two million dollars of Product Liability Covera>;etwo million dollars ($22,000,000) of Product Liability Coverag per occurrence. 1.9 The Vault Tank to include a Warranty for 20 or 30 years, depending upon model purchased. VSLW.BT 1 Revised 3/95 Serving the Industry with Quality Tanks and Systems 2.0 PRIMARY STORAGE TANKS: 2.1 The primary storage tank shall be Rectangular in design and constructed of UL specified steel thickness with continuous welds, inside and out, and have a capacity of 250 to 12,000 gallons. 2.2 The primary storage tank shall be constructed in accordance with UL-142 Standards, and carry the appropriate UL label. 2.3 The primary tank shall be fitted with: a 4" Fill Port w/ 16 gallon Spill Containment and Locking Lid; either a 4", 6' or 8" Emergency Vent Port; a 2" Working Vent Port; a 2" Liquid Level Port; a 2" Port for Dispensing Pump; a 2" Auxiliary port; a 4" Phase I Vapor Recovery Port and a 3/4" drainback port located within the spill container. (Additional ports are available.) 2.4 The primary tank shall be pressure tested to U.L. 142 Standard (minimum 3 to 5 psi) at the factory and shall also be field testable. 2.5 The exterior surface of the primary tank shall be cleansed of foreign material and coated with a corrosion resistant industrial epoxy paint. 2.6 The primary steel tank shall be designed to store M85 (methanol), alcohol petroleum blends or 100%methanol. 3.0 INTERMEDIATE LEAK DETECTION and INSULATIVE BARRIER: 3.1 Each primary tank shall be completely surrounded by a separate intermediate barrier which creates a void space around each tank and provides added insulation to the primary tank. 3.2 The intermediate barrier shall be constructed of 1/4 inch thick polystyrene. 3.3 The intermediate barrier shall separate the primary tank walls from the fire protection material; thus, creating a separate leak detection envelope around each primary tank. 3.4 A 2" monitoring tube shall access the space created between the walls of the intermediate barrier and the primary tank to detect leaks. 4.0 FIRE PROTECTION: 4.1 The fire protection material shall be light weight concrete and surround the primary tank at a thickness of six (6) inches, and provide a minimum two (2) hour protection per UFC Appendix H F and Standard A-II-F and UL 2085 Protected Tanks. 4.2 The fire protective material shall have been tested and approved by a nationally recognized testing firm. 4.3 The fire protective material shall be of a monolithic pour, performed at the factory. VSLW.BT 2 Revised 3/95 4.4 The fire protective material shall be verified by a nationally recognized testing firm not to spauld, crack, or otherwise be adversely affected by maximum temperatures of 2,000'F. 5.0 BULLET RESISTANCE: 5.1 The fire protected primary tank shall be tested by a qualified engineering firm to be resistant to penetration of the primary tank by a 180 grain, M 2 Ball bullet,traveling at a velocity of not greater than 2700 feet per second, when fired from a 30.06 caliber rifle, located a maximum of 100 feet from the target. 5.2 The fire protected tank must be able to be repaired in the field by a factory representative according to written factory procedures, when impacted by a bullet. 5.3 The factory must be able to certify that the primary and secondary containment do not leak, and that the fire protective material regains its minimum two (2) hour protection. 6.0 SECONDARY LEAK CONTAINMENT TANK: 6.1 The secondary leak containment tank shall be a rectangular steel tank constructed of UL specified steel thickness with continuous welded seams inside and out. 6.2 The containment tank shall be tested liquid tight at the factory and shall also be field testable, (minimum 3 psi). 6.3 The containment tank shall provide reinforcement for the 6" of light weight concrete. 6.4 The exterior surface of the containment tank shall be cleansed of foreign material and coated with a corrosion resistant industrial epoxy paint (3 to 5 mils dry thickness). 6.5 The containment tank shall provide 3601 Radius containment for the primary tank, extending six (6) inches around the primary tank. 6.6 The containment tank shall be fitted with: a 2" Annular Space Monitoring tube and either a 4", 6", or 8"Emergency Vent port; in addition to openings for all ports in the primary tank. 6.7 The port openings in the top of the containment tank shall be constructed with full welds to prevent moisture from seeping between the fire proofing material and secondary and primary tanks. 6.8 The top of the containment tank shall be sloped so that water will not accumulate. 6.9 The containment tank shall have a two (2) inch monitoring port including a tube which provides a means to detect product leakage from the primary tank into the leak detection envelope directly surrounding the primary tank VSLW.BT 3 Rexised 3/95 rt r.r. H ER ok. ' Containment Systems Inc. A JU SSIOIARY OF HOOVER GROUP. INC. r P.O. BOX 396 SEVERNA PARK, MARYLAND 21146 410-987-3800 800-777-2823 FAX 410-987-3890 SPECIFICATION SUPPLEMENT VT- 1 HOOVER VAULT TANK UL LISTED 2085 "PROTECTED SECONDARY CONTAINMENT" TANK The following information should be added to the Standard Hoover Vault Tank Specifications dated 3/95. This information pertains to Hoover's new listing under Underwriters Laboratory U/L Standard 2085 "Protected Secondary Containment" Tanks. 1.0 GENERAL TANK DESCRIPTION: 1.1 The Hoover Vault Tank is constructed and listed in accordance with Underwriters Laboratory Standard 2085 Protected Secondary Containment Tanks. This listing exceeds the requirements of The National Fire Protection Association Sections 30 and 30A and The Uniform Fire Code-Articles 52 and 79, Appendix II F and Appendix Standard A-II-F-1. 1.2 Hoover Vault Tanks are constructed and listed as, double wall tanks utilizing steel primary and secondary tanks. Lightweight concrete surrounds the inner tank providing a 2 hour fire rating. 1.3 The Secondary Ccntainment Design shall be listed under U/L 2085 to provide 110% leak containment by utilizing only-Lvo steel tanks, without any material surrounding the primary tank that creates a void space for leak detection in the light weight concrete. 1.4 The lightweight concrete surrounding the primary storage tank shall be listed to allow liquid from the inner tank to communicate with the leak detection tube through the fire protection material. 1.5 The tanks shall have the listing mark from Underwriters Laboratory for Standard 2085 Protected SECONDARY CONTA iI W7 1N 'Tanks. vSLw.B-rS 3/95 r m- •� O`� �L I I/I at FND. 3/471RON PIPE :3 1 0.26N. Or CALC. POSITION ,OG O 6' CHAIN �� PLACE FENCE 1' INSIDE LINK FENCE kT -- OPERTY LINE. II t »aA »a •»a.., •»ari .»:s: •» •"IIs •»a.• •»aaz m7f -»ua : \ .».n .»4 r .aw.sl i a 29 5 T� WALK A S ----- -� �, +\ fNp. J/4 IRON PIPE Yy Fyr_ n - S87?J'34� `�•� 0.1JN. OF CALL^ it •LL`L`�t`L�' _ eo 1 '� 21.4' POSITION ,� c� PL.p,N NORTH -� INSTALL BOLLARDS 60Q I I; �I •'••-�� in = PPROX. DRA: FIELD AREA 15 15' APART _ I' s 4 `� _-� --------------- \ ,' j r a ' • -220.31' \ `O y 'r' I'. ' z» •m,o -azos -IsaT7 :siiii'.'.'.'.'.f.'.'.'.':a•ioi..'. rau.. I •»wn 2" .»..a II ; 30 LCLL,.LL�� _ -r__ iv+'.'. EMERGENCY GENERATOR •'•1�•.3'•1M E tDNC. ................ 1 �.. PAD 2'-0• LONGER . 1 .....'.'.'.:.'. VALLEY CUTTER..... ".'. .... .. -\ 'I THAN GENERATOR .. . .. ...........'.'I...'..'''. 150•I.F'• •'•' SSELET�X MAIL FLASHER - :.rp;'. &(-n PAINTED 1' . .:':: ::::..::.:::: 1 LEGEND ALL-AROUND ..��f�AINTEp...e ' 294.23 ' m ITE STRIPE 3'.'lMOE'.CONC;.'.' ...... .. ............... . .. -%401 TE , �.'..'.'.'.'.'.'.':.:.:...9Ec. ANSbTiON! �. .. p•) vAlLEY.'GUTTER' ; \j,PROP-fJNE; ct......... ::..' ' ....XI& m Z ;r: .»z» •m.a, .»zw R.'. i�....1 :i .asai :isiai. ; .1w�s--� .»..x •»•.� I II El A.C. PAVING � :.'.'.'.... I 1 1 e CONCRETE •1 ....�,.. < .'.'.'.'.'.'...........:. I PRESERVE Q "`'•J+'... ^ ® VMEEL STOP t.. :.:.Bs-' : .'.�. 6' •.'.'.'.'. , I DRAIN FIELD GRAVEL® .�•.•� '•.:.� .....1- 1 DISABLED® r:•........-_'- :.'.•.•.'.'.'-..-;-•_•�•�-� I I 3 '� .. �f--' ���_�-•-•_- 32' GATE (�•) tr �•` `-Z t..... {{�,�,, 1 PARKING SPACE SIGN k sYMBDL -I• 1 PITS I F CONCRETE - SEE sTRUCT DwfS �,- ... a= W •»,. t^.:.:..�n.0 m.s •m.o •m.e /.' �f'.':isi .aaiii:'. ,r J .»wn •».TTTf' ;4 I = 50'R � 5�,WtNING .'.'::.' L__J`` I CONCRETE WHEEL STOP U •'•'.'.:. 21. -1N GUARD RAIL �...... 1 Q W : 1 e1j88 LF SEPTIC Il; IJI BOLLARD • Q`LL�� W 6. GUARD :..::..:. DRAIN FlEID II ;I, - - GUARD RAIL r• , LL[[ - � -.'.'.�.r' '.'.'..:.. ......... .....•...- . ............ :._.:.'.:....:..:._...:.:.::-� SEE SHT. C2 FOR 10' MINA ,I ', ZEL - �,...,: SEPTIC SYSTEM LAYOUT I II, �................ .......... nape .»..,. e C SET REI3AR k CAP LS./ 18902/13670 u",` u •Ssty 'a .»tw ..A,2kp1......:.:.:.:...:iu.o-..........,sst•a...:........�rtm .........2fir.........:.-.•.-.. ►.�•-.••.......... •.•.•.•.'.'.'.•:...•.39...:..........,ssaaa .. �.......' .'......... 11 ON PIPE AS NOTED "�-' '-T- I I O FND HEBAR R ` fr ,.... :INSTAIJ.'BOLLARDS'.. 1 I' MANHOLE L�1 L.LLL - .......... .. .......................................... ... ....... .. .. .... _ I I , .... ... .. I „� b3 i' .. -EVERY•15''JO' - -- ------- I .... .................... ........... , LLLL,u.0 r .. .. i A N .. .. .�'. ❑ T SI .. ...•R�' ................................. ........ .................. .........P.ROTECT.'DRAIE't.fiEtO�.'. . - I r, 1194 CATCH 8 i on— .... .. ...'/.'. ......... ...... }•+ C. RISER TONER / ... .. ........... ....... _ ELEC.E I ti o ,•, Z .. .......... . ... ...... r , / - ..... ..... N: ................... �• CASING....... fr i l!a WELL D - -� .. ....a•iu:..........:r� :iviai'..........I ova�i:' �;I oa WATER VALVE \• :, p c - O E��11rL fSLr?h' �.-- .'.:.:.'.'.:.: :. E I ' I---,� ... .............. ... ........ ....................... I m WATER METER coCDNC. G I IfSC ZONE 1)S SLF_ '.'..'.-.'...'...'.'..." -.'.'..'..... ......'.'.. ' I ... ......... .. ..... _ ` l FIRE HYDRANT s• ..." .o ......... POWER TRANSFORMER .. N ............................... i REMOTt wlT�rl .... ........ ........ .1 i I i >uNcnav eox su o Porl _ I, .. ...... ........ I, 4 UTILITY POLE -'a.a .oi'..... I .'.'.'.'.'.'.'.'.'. .'.'.'.'.'.'.' E— GUY ANCIIOR r I .......................... E m I ........:.:.:.:.:...:... :.:.:.:.......................... :;gyp - , -0 GUY POLE (�.?y,I ...... O IIGriT 272' ..... ......................... I® INFILTRATION ................. �i T V -? I .............'.'.'. "too'' - II t7l,I •A•asa SPOT EL£ n nON �- - - POND I Y :. - Ik1 OBSERVATION WELL •»aae •»+. •»zo+ .»a.n` m o •m.r. :aioa. iv>ri'. ........:iviil'. ......r Its...........'.rind:-........:r'a' zta; »i '�Sa O FILLER CAP ---------..-;`; ............. ....... ....................... .. ....... zB9 \ ....... �_ il;I ABBREVIATIONS l I ..... ....._� _ I ------ - - .. .. ... ..... ..... - _ -�-- ......................................:... ... II coNc CONCRETE - J .... - I,'I ' -LF LINEAL FEET J _ �2cvr --I .as= !rn. •»,.n -'-� •m,a •ms. .mn oe zn. --_- .'=vz:' /'_ =ni 1 na. ;I� I' R RADIUS II MIN. MINIMUM I I TRANS. TRANSITION I , S872XJ4 E I I ' 93 �•�-" L-1 30' MIN. IIf I it �I .-s•r, ."ISO .m.x .»,In .m.a, .»zac •»�« » 1�II II ��• a'IRON PIPE� FND. J/ F ��. -------------- ,-----------p.2s'N. &0.09'W Or ------__ "� CACG_POSITION J I I'1I lil _ NOTE: REDUCED PLANS, DO NOT SCALE DRAWINGS. AI�fI . 10 WASH �e►�8r„ je ►KLW AAOf=- r�noa�Ao moQT�a �' �, Washington State SHELTON C 1 , SECTION FACILITY `/ II�eR ROBeWafer Engineering, Inc. OAP Department of Transportation GHWT 3 - •„ 1932 Fnt Avenue, Suite 711 Seattle, WA 981D1 /L PROJEM W. OL1464 , Y! (205) 441-9385 FAX(206)448-692.2 057W PAVING AND Q NEWT FM W. .. AS mu un I mscm to �� an �vmAow rr DAM I wawa Ito- LAYOUT PLAN �