Loading...
HomeMy WebLinkAboutCOM2007-00058 B-1 Final Admin. Ofiice - COM Permit / Conditions - 1/5/2010 r MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 � Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton, WA 98584 COMMERCIAL BUILDING PERMIT COM2007-00058 OWNER: MASON COUNTY PUBLIC WORKS RECEIVED: 5/25/2007 CONTRACTOR: ROGLIN'S INCORPORATED 360-532-5220 LICENSE: ROGNL**342LF EXP: 8/1/2009 ISSUED: 5/23/2008 SITE ADDRESS: 100 W PUBLIC WORKS DR BLDG A SHELTON EXPIRES: 11/23/200E PARCEL NUMBER: 420021000010 LEGAL DESCRIPTION: PCL 2 OF BLA#06-72 PTN OF W1/2 NE PROJECT DESCRIPTION: DIRECTIONS TO SITE: B-1 Intersection of Hwy 101 & Hwy 102. Admin. Office General Information Construction&Occupancy Information Type of Use: admin offices Insp. Area: No. of Units: Type of Constr.: 2ANo. of Bathrooms: 12 Occ. Group: B/A/S Type of Work: NEW Fire Dist.: 16 No. of Stories: 1 Occ. Load: 415 Valuation: $ 2,162,489.50 Building Height: 30 Pre-Manufactured Unit Information Square Footage Information Make: Length: Lot Size: cov entry: 1,700 Model: Width: Building: 20,416 Year: Serial No.: Basement: Parking Spaces: Setback Information Shoreline&Planning Information Front: E 190.00 Ft. Shoreline: Ft. Rear: W Ft. Slope: Ft. Water Body: Shoreline Desig.: Side 1: N 360.00 Ft. SEPA?: Comp. Plan Desig.: Side 2: S 440.00 Ft. Fire Protection System Information Auto Fire Alarm System?: Emergency Key Box?: Standpipe?: Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?: Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?: COM2007-00058 Please refer to the following pages for conditions of this permit. 1 of 10 r Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 2 Evaporative Cooler 1 EH Plan Review TAAr rlRnnn7 It7c;nn _,;,?nn7nn Kitchen Sink 3 Exhaust Hood 2 Plan Check Fee ni r 7n'Annn7 (�a n*?a Qi glgnn7nn Lavatories 9 Furnace<100K 1 Non-Res.Energy Code ni r. 7i1,Ai,?nn7 aaa nn cl?nn7nn Water Closets (Toilets) 9 Ventilation Fan 4 UFC Plan Check Fee ni n 711z/'?nn7 as ms a7 Clgnn7nn Urinal 3 Heat Pump 4 Building State Fee ni r. 7i1,innn7 TA rn q1qnn7nn Drinking Fountain 1 Building Permit Fee nl r 71jAnnn7 Ica 979 9n Stgnn7nn Mechanical Fee ni r 7i1 snnn7 a1 sR ar, qt 7nn7nn Mechanical Base Fee ni r 7i1 signn7 �.t7r, in C19nn Inn Plumbing Fee ni r. 7i1,tignn7 I.t7n7 Qn ri 7nn7nn Plumbing Base Fee ni r. 7/1i/7nn7 tqq nn ;ignn7nn Planning Review Fee rnAH Qi1Qignn7 o7Rn nn glgnn7nn Total $19,147.75 CASE NOTES FOR COM2007-00058 CONDITIONS FOR COM2007-00058 COM2007-00058 2 of 10 1) 1. A stormwater site plan with low impact development features such as pervious paving, rain garden infiltration and native vegetation, will be ` created and implemented prior to development, clearing, grading or construction of any portion of the proposed development. 2. The proposal shall be required to control erosion during construction. Removal of vegetation should be minimized and any areas disturbed should be restored to prevent erosion and other environmental impacts. 3. Site is within a portion of the county designated as Class II Critical Aquifer Recharge Area, under Critical Aquifer Recharge Area Chapter 17.01.080 of the Mason County Resource Ordinance. All provisions of the CARA chapter shall be followed including obtaining a Mason Environmental Permit, application of Best Management Practices on site, and an engineered stormwater site plan in compliance with Ecology's stormwater, water quality, Hazardous Waste, wetland and solid waste program BMP, and BMPs from the departments of Health, Agriculture, Transportation and State Conservation District Office. 4. Project applicant shall develop in compliance with Geotechnical report completed for this site by Aspect Consulting dated January 22, 2007 and updated March 26, 2007. 5. In accordance with discussion between Squaxin Tribe and Mason County at meeting on April 9 2007, Mason County and the Public Works department propose to work with the Squaxin Indian Tribe to craft a Memorandum of Understanding between the two governments, relating to proposed project measures, which further reduce impact to the aquifer beyond that of usual development impact through a series of additional measures. These proposed measures and the memorandum are being developed, but would include such measures as low impact development, and minimizing water withdrawal through conservation measures, pervious pavement, stormwater infiltration, rain gardens and native vegetation, and proposing to h oil up.to City of Shelton water when it becomes available. Although this proposed Memorandum of Understanding is still under way as of this da it iie understanding of the parties that it shall be completed and in place prior to the issuance of building permits for this project.x 2) MUST SHO RO.O,F OF APPROVED WATER SOURCE PRIOR TO TEMPORARY/FINAL OCCUPANCY OF ANY STRUCTURE ON SITE. X c�,/ 3) Accessible route within the site shall be provided from public transportation stops, accessible parking and accessible passenger loading zones. At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces on the same site. An accessible route shall be provided to each portion of the building and to accessible building entrances. All accessible elements shall be identified by the International Symbol of Accessiblity as specified in the 2003 International Building Code, Section 1110. At least 50% of all entrances shall be accessible to persons with disabilities. Where provided, thresholds at doorways shall be 1/2-inch max. height. Ch"ges . height greater than 1/2-inch in height shall shall be ramped. X �s 4) Owner/A? ; t is re risible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. l X V V 5) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE RE(aYIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF U R LIPANCY WOULD RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x 6) Changes to ap rov d b ilding plans that affect compliance to the current Washington State Energy Code ( SEC'), ventilation and Indoor Air Quality Cod IA ), ilding/Plumbing/Mechanical Codes and/or Mason County Regulations shall be approved prior to construction. X COM2007-00058 3 of 10 r c 7) Deferred submittal has been approved as follows: 1) Building structural calculations, prepared by the structure engineer, AND final foundation design, prepared by PCS Structural Solutions, shall be submitted and approved by the Mason County Building Department prior to foundation inspection requests. 2) Special n pection authorization shall be submitted and approved prior to inspection requests. X �� 8) Any cha' ges in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are removed, ap o al will not be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected th M �qfi County Building Department prior to any further inspections being performed or approvals granted. X A 9) CONS UCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conform ith the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason ui g Inspector shall be made prior to requesting additional inspections. X -"T 10) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-com n with M son County ordinances and building regulations. X COM2007-00058 4 of 10 i 11) An NFPA 13 compliant fire sprinkler system must b03ristal d. A separate permit is required, application and issuance must be made prior to installation or calling for inspection. X An NFPA 72 fire alarm system must be installed. A separate permit is required, application and issuance must be made prior to installation or calling for an i p c>ion:'rfhe system must be monitored by a UL certified monitoring company. X 2A10BC fire extinguishers are required throughout the building including the attic mechanical areas on the second floor in accordance with IFC 2003 chapter 9 and NFPA 10, the maximum distance of travel can not exceed 75 feet in any direction. Maximum height above the floor is 60 inches to the top f e njts. X A key box is re Uired to be installed per the 2003 IFC chapter 5 section 506. Please contact the local fire district for more information and inspection. A bo�vyi be required on all structures located on the site and on all gates. X Bollards dr ired t e constructed per 2003 IFC chapter 3 section 312. X Fire prote' tion equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves or other ' e detec Z t* n, suppression or control elements shall be identified for the use of the fire department. Approved signs required to identify fir tiorf eq pment and equipment location, shall be constructed of durable materials, permanently installed and readily visible. X Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating ELECTRICAL ROOM or similar approved wording. The disconnectiN means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and duably marked t ate �s pose unless such purpose is clearly evident. X The Mechanic efr�gera 14 used in the mechanical room shall be in compliance with 2003 IFC chapter 6 section 606. If any curcuit containing more than 220 po of r u Al or 30 pounds of any other group refrigerant. X 12) PER TI E 14 MASON COUNTY BUILDING CODE -CHAPTER 14.17, STANDARDS FOR FIRE APPARATUS ACCESS ROADS - 14.17.110: A fire apparatus access road in excess of 14% grade and more than 150' to new residential or commercial structures will require an automatic fire sprinkle57 install d. Contact the Mason County Fire Marshal at(360) 427-9670, extension 273, for further information. x / - 13) This project is approved with a fire-sprinkler and monitored alarm system installed in accordance to Fire Marshal approval. The sprinkler system shall be i s le and "n pected prior to the framing inspection performed by the Mason County Building Dept. X f COM2007-00058 5 of 10 14) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and /or land modifications (grading, cuts, fills, etc.) required in the geotechnical report/assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. Site develop t shall comply with the recommendations outlined in the geotechnical report completed for the site, prepared by Aspect Consulting dated Janua 2, W7 and updated March 26, 2007. Inspection report(s), verifying that site development, has been completed in accordance to the recom e f s shall be submitted to the Mason County Building Dept and available on site during inspection. X 15) Provisio4 for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access co cting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction hi his prop ed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned c1l ma/Ict your project. X 16) IF CITY SEWE r AVAILABLE AT TIME OF OCCUPANCY AN ON SITE SEPTIC SYSTEM MUST BE INSTALLED. x v 17) All approved plans are required to be on-site for inspection purposes. If inspection is called for and plan Te not on site, Approval WILL NOT be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will b gel collected by the Mason County Building Department prior to any further inspections being performed or approvals granted. YJY 18) All property lines shall be clearly identified at the time of foundation inspection. X I 19) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks onqtary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The er n sning this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 17 20) Retaining walls needed to sup ort a surcharge such as struc r r add, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X Y 21) Per 2003 IRC -SECTION 1609 -WIND LOADS - 1609.1" Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum ind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 B I WI PEED (3-SECOND GUST)the wind speed for Mason County is 85 MPH. X �J 22) Separate building permits and approval is required for the following.. 1) Monument Sign 2) Fueling station and canopy 3) Fences rea er t a 6-feet above grade. X COM2007-00058 6 of 10 23) The approved site plarz is required to be on-site for inspection purposes. If inspection is called for and the site plan is not on site, Approval WILL NOT be granteVD ition reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by the Mason County Buildingen rior to any further inspections being performed or approvals granted. X 24) Recyclable materials olid Waste Storage: Space shall be provided for the storage of recycled materials and solid waste. The storage area shall be designe to e the Veqds of the occupancy, efficiency of pick-up, and shall be available to occupants and haulers.X 25) International Buildig Code CHAPTER 17: IN ADDITION TO THE INSPECTION REQUIRED IN IBC, SECTION 109, THE OWNER OR THE ENGINEER OR ARCHITECT OF RECORD ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS WHO SHALL PROVIDE INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF WORK LISTED UNDER CHAPTER 17. THE SPECIAL INSPECTORS DUTIES & RESPONSIBILITIES SHALL BE AS SPECIFIED IN CHAPTER 17. Special inspection a orts s all be submitted to the Mason County Building Dept. and available on site for inspection. X 26) A structural observation, as defined in Chapter 17 of the International Code, shall be provided b the engineer or architect of record responsible for P Y 9 P the structural design or another engineer or architect designated by the engineer or architect or record. Prior to the finAt �p4 ection f the structure the structural observer shall submit written statements to the Mason County Building Department indicating th t vises have been made and identify any reported deficiencies. X 27) Washington tate Energy Code Compliance is approved as follows: ENVELOPE: Prescriptive Table 13-1, Other fuels The building envelope shall be insulated as follows: Wall insulation R-19, Ceiling insulation R-30, slab insulation min R-10, windows U-.45 or less, doors U-.60 or less. All insulation shall be installed to the full depth of required R-value and shall not be compressed. Evidence of u-factor for windows and doors shall be available for inspection. R-10 slab insulation shall be installed around the entire perimeter of the heated space and shall be installed so that insulation begins at the top of the slab and extends downward to the top of footing or 24-inches. MECHANICAL SYSTEM: Approved as shown on approved building plans. LIGHTING: Approved as s wn approved building plans. X COM2007-00058 7 of 10 28) The mechanical system for which energy consumption, performance, or mode of operation are regulated by the 2001 Washington State Energy Code (WSEC) and Ventilation And Indoor Air Quality Code (VIAQ) shall be tested to ensure that control devices, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Drawings and notes shall require commissioning in accordance with WSEC section 1416.4. Lighting controls shall 0,tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with the p ved plan and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing no s all reqj commissioning in accordance with WSEC 1513.7. X 29) 1. A stormwater site plan with low impact development features such as pervious paving, rain garden infiltration and native vegetation, will be created and implemented prior to development, clearing, grading or construction of any portion of the proposed development. 2. The proposal shall be required to control erosion during construction. Removal of vegetation should be minimized and any areas disturbed should be restored to prevent erosion and other environmental impacts. 3. Site is within a portion of the county designated as Class II Critical Aquifer Recharge Area, under Critical Aquifer Recharge Area Chapter 17.01.080 of the Mason County Resource Ordinance. All provisions of the CARA chapter shall be followed including obtaining a Mason Environmental Permit, application of Best Management Practices on site, and an engineered stormwater site plan in compliance with Ecology's stormwater, water quality, Hazardous Waste, wetland and solid waste program BMP, and BMPs from the departments of Health, Agriculture, Transportation and State Conservation District Office. 4. Project applicant shall develop in compliance with Geotechnical report completed for this site by Aspect Consulting dated January 22, 2007 and updated March 26, 2007. 5. Subject to provisions of intergovernental agreement between Mason County and Squaxin Tribe. 30) Owner or engineer or architect of record acting as t owners's agent shall employ a n independent civil engineer, licensed in the state of Washington -to inspect the installed stormwater f a res l r consistency with the attached stormwater plans and BMPs. That civil engineer shall submit written statements to the Mason County epartment indicating that the inspections(s) have been made, and that the final installation is plans. x li31) This parce ee i smoke management zone. Please contact a fire warden at(360)427-9670 ext. 459 for further information. X 32) Landings and it most eet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approv e I n" nsure these structures are shown and meet the setback conditions listed. X 33) By defini on, pr a to ks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these ru red eet the setback conditions listed. X COM2007-00058 8 of 10 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress ection.The owne or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property nd ructure folr rev and inspection. OWNER OR AGENT. _ __ DATE: COM2007-00058 9 of 10 N - -- --- CONCRETE MECHANICAL MANUFACTURED HOME Footings I Setbacks gate By Ribbons Gas Piping Interior Date By Interior.Date By Dale ay Exterior Date By Exterior-Date @ Set-up point Load f Isolated Footings NN§ULA nON Date BG f SLAB INSULATION BY Date By SO By FIRE DEPARTMENT Foundation Walls Floors Date By Date By Data By DECKS FRAMING wells Date By Date By Date By PROPANE TANKS PLUMBING vault Date By Date By OTHER Atdc Data By Date By Type: Date ayDRYWALL D.W.V Type: Int Brace Wall Date By Date By Date By FINAL INSPECTION Water Line Fire Seperation t6 date By Date By Data BY ID Pass or Request Inspect. Type of Insp. Fail Date date Bone By Comments Lzc�, 101 zT ks Ae iG 0 :h• I'rGt�� k65 it !0 g ! !D Og N b4111 Ref t)elX ✓ NuI tiss _ l H lU � p (..�� 0 o K ' CONCRETE MECHANICAL MANUFACTURED HOME > N _ o Date By O v Footings Settiac Gas Piping Ribbons Z o Interior Date By interior-Date Wnl()'6 BY L10 Date By n CPExterior Date By Exterior-Date B Set-up O INSULATION c Point Load/Isolated Footings Date By Z Date By BG 1 SLAB INSULATION Data By FIRE DEPARTMENT Foundation Wails Floors Date By C Date By Data By DECKS � FRAMING $• walls?Tk_W 6`6 `ice' \ Date By n Date 10 O . By (�&IL Data 1 pS BYLA(.j PROPANE TANKS PLUMBING vault -NX4,)% 110c_ Date By O Date-7 1J6f BY LAW sc,,i� i yr OTHER Groundwork WI Attic C/) Date By Type.r�l a-tj t,iA Date BY Date 9,Z410 S! BY C44 D.W.V DRYWALL Type. O Int Brace Wall Date By Date � l7 06 BY 9 Date By FINAL INSPECTION IN) CDWater Line Fire Sepe ration O Date By Date By Date ` S 10 By O Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments o 0 1� ZI U7 IL �.To rd-1 l S.P -rtS !Z-lo-cN l2-/1-61 t� >Gft•4"''�l �. l 7�d SFr Lb�( -fv 1 FAX, 0Y__ 6 7101` V Sf 1 I 0 V vt'j o� g-f✓�turr. c�� 4S 7-1 1-cb u � I 1- ^Q co J. (�ftr,'(tk td2 �fG t'0 7/1b10V 0 �116�oSs C, � c . _sulu c 1J�-li� - r�'ra�.v 0 4 I m m de.;AeA pt ,', V.rq t 1 .0 wc'te �•t0n, W w� CONCRETE MECHANICAL MANUFACTURED HOME Footings !Setbacks Date ' By Ribbons Gas Piping Interior Date By Interior.Date By Date By Exterior Date By Exterior-Date B Set-up Point Load f Isolated Footings INSULATION Date By BG l SLAB INSULATION Date gY Date By FIRE DEPARTMENT Walls Floors Date By Date By Data By DECKS FRAMING Walls Date By Date By Dare By PROPANE TANKS PLUMBING vault Date By Date. By OTHER Groundwork Arc Date By Date By Type: y D DRYWALL ate BY D.W.V Type: Date B Int Brace Wall gate By � y Gate By FINAL INSPECTION 2 Water Line Fire Separation �8 Dato By Date By Date By I Pass or Request Inspect. Type of Insp. Fail Date Date Dane By Comments 'f Gss � 2� �� ti Z� v� Z�►L 78 a s 0 BuildingPermit # a�4� 000 5�NIASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance A/ -&a A � OQ AA e-- p- _ e z - c, /f15 6A-J wca dl1 S o1v i u a w Y Varehereby notified thhMve corrections shall be made BE ORE �OCEEDINP WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to T� ❑ This is not complete inspection Department Date l0 Inspector 741!�4f ■ vO NOOT MOOV THF , T A Building Permit # 000'ffMASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location P /D / pa'W c This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance 2, G V /L L,Aoi91 r q E SSG Q Pro kl i Eiz r y 13. R / &IA 130 E c ! ill 2 A # E - 1 PAql CS Ow ,r AJ e Lo- You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department D C- Date Inspector Arc c— ■ ou No *T ► MOOV , THIQ T 'RL � '- L(1 2007) Debbera Coker- MCPW Accessible Shower Seat Page 1� From: "Bjorn Gilje" <Bjorng@HelixDesignGroup.net> To: <Dlc@co.mason.wa.us> Date: 10/29/2007 11:55 AM Subject: MCPW Accessible Shower Seat CC: <charlesb@co.mason.wa.us>, <ken.hawk@wcs-inc.com>, <ryan@rognlins.com> Debbera Coker, RE: MCPW- Permit#COM2007-00059 Building#2 We have specified a fixed in place, fold down seat for the Accessible Shower in the men's and in the women's Shower Rooms and are asking if a portable shower seat is allowed to substitute for this fold down unit (B-5181 by Bobrick)? 0 Are portable seats that you could find in Healthcare Service Retail f�. Sales allowed as a substitute for the fold down permanent seats? The reason that we are looking to substitute is because the permanent wall mounted fold down seats are difficult to clean, can not be positioned to best suite the transfer and we have had one situation where an individual slid off the fixed seat and as a result, never used it again. Let me know if a substitution is allowed. Thanks, Bjorn Gilje HELIX DESIGN GROUP bjorng@helixdesigngroup.net<mailto:rbjorng@helixdesigngroup.net> helixdesigngroup.net <http://www.helixdesigngroup.net/> p.253.922.9037 I f.253.922.6499 6021 12th St E Suite 201 1 Tacoma, WA 98424 1 TACSystems Admbk DATE 11/01/08 PAGE 15 UNIT EF-123 AIR MOVING EQUIPMENT DATA AREA SERVED: KITCHEN 123 FAN EF-123 EQUIPMENT MFG. GREENHECK EQUIP.LOCATION CEILING MODEL CSP-A1410-QD TYPE/SIZE SERIAL NUMBER 11298655 FAN DATA SPECIFIED ACTUAL FAN SHEAVE TOTAL CFM-FAN 900 870 FAN SHAFT TOTAL CFM-OUTLET 900 870 BELT SIZE DIRECT DRIVE FAN RPM 1480 1450 QUANTITY ESP 0.50 0.68 SHAFT C/C SUCTION SP -0.12 DISCHARGE SP 0.80 MOTOR SHEAVE MOTOR SHAFT DIRECT DRIVE SHEAVE ADJ. MOTOR DATA MOTOR MFG. FASCO SPECIFIED ACTUAL MOTOR HP 822W VOLTAGE 115 119 SERVICE FACTOR AMPERAGE 7.8 3.9 PHASE/Hz 1160 HEATER SIZE/RATING THERMALLY PROTECTED MOTOR RPM 1450 1450 MOTOR FRAME# SPEED DIFFUSER AND GRILLE TEST SHEET AREA SERVED NO. CODE SIZE AK DESIGN INITIAL FINAL FPM CFM FPM CFM FPM CFM 123 E1 EG 22X22 1.00 900 870 - 870 TOTAL 900 870 870 REMARKS: FORM 2A