Loading...
HomeMy WebLinkAboutSWG2024-00182 - SWG Application / Design - 4/29/2024 4 MASON COUNTY 15NBTH ELTON: , 0427-97 ,rXT0 40 SHSTREE SHEL ON, EXT54 BELFAIR:360-276-4467,EXT 400 Public Health & Human Services ELMA:360482-5269.EXT 400 FAX 360427-7787 On-Site Sewage System Permit: SWG2024-00182 APPLICANT EMPIRE HOME CONSTRUCTION Phone: 360-751-1745 Address: PO BOX 241 KELSO, WA 98626 OWNER FLETCHER CAROLE Phone: Address: 4915 N WINNIFRED ST TACOMA,WA 98407 SEPTIC DESIGNER PAULAJOHNSON' Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION,WA 98592 SEPTIC INSTALLER ALLAN KIRK` Phone: 360426-0574 Address: 30 E WILCHAR BLVD SHELTON,WA 98584 Site Address: UNKNOWN Primary Parcel Number: 320215804059 Permit Description: New 3bd ATU to pressure trench Permit Submitted Date: 0412912024 Permit Issued Dale: 05/14/2024 Issued By: Rhonda Thompson Current Permit Fees Paid: $540.00 (additional tees may ee requires upon mswimon or system). Permit Expiration Date: 05/06/2027 (based on date onnsceCmm Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specked on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backlill of system components. 5 Installer is responsible for obtaining Septic DesignenEngineer installation approval prior to b8cidZ11 of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/healthionvironmental/onsiteloss-inspection4equest.php or call: 360.427.9670,extension 400. OFFICIAL USE ONLY ASON COUNTY OMMUNTTY SERVICES IT Mk,N,n(,mMUNVH®MVEmmu WkftNW vl O m „ SWG )-t9 -L - G D 2 N ON-SITE SEWAGE SYSTEM APPLICATIONTr 3 FHONE GO r APAUID T 360 751-8062 Empire Home Construction ) m q a MAILING ADDRESS-STREET CT'.STATE i LP LOGE Kelso WA 96626 ^ m P.O. BOX 241 O NTEAD NM-GTREET CITY DP CODE Shelton WA 98584 E Lynwood Dr PHONE NAMEOFOGGIGHER �36O)898-2255 Arrow Septic Designs o RICHE � NAM E OF I NGTALLER 36O 90-314k Mason County Excavating ( n ^' .-,WRNGRR 91 PERMIT IPE(® ElMMEGL05 AEEPRIVATEINDIVDU AL UPRNATETWAY U Z I— QQ NTIAL0G5 7ICOMUNtfYOSS ®PUBLIC WATER SYSTEM I I I WMOF NI...) VI ®NEWCONSTRUCTIONIUPGFAOES 51RERNRIREPLACEMENT OTHERURFACIWSEMOE 1 OTABLEILVIRER bSURFACING BE4WGE GE%IBTING FNLVRE OSHORELINE m Io' j`y , wBM A Or saE WDEBICN FORM(REQUIRED) MDG�SEPTIC DESIGN(REQUIRED) SEOROOMs 36R .188Cres x l0 �WAIVERIS1(IF APPLICABLE) OIREGIIONS TO TE AN06RE Go out Hwy 3 and turn (R)onto E Agate Rd. Turn (R)onto E Crestview Dr.Turn(L)0nto E I+' I a Hillcrest Dr.Turn (R) onto E Kingston Way. Destination on (R). Yellow sign: "Empire Homes o I c -Lot 59" - I 1 m M EFE EGRET WAGGED MW MAIN ROAD AND TEST NCLEE MU4T BE MfAEDWHMSING.ENUMEERS I (o OFFICIAL USE ONLY BELOW THI5 LINE L. UPGRADEIFAIWRESOVEOIIM�P"MGIsu�) �VCLUNTARY ❑MAINTENANCEIPDMPING OBUILDINGPERMIT OIIOMESALE OOOMPWW ❑OTHER: CONMFMB�LWOITIONS IN6PECTOR SdLIOGE ;I*AL � I Sl 1v>5 Wiz : 0 _ Zj s� Iz�+ rA o � � TodT SZ+ W-+-AV Z APR 2 9 2024 '�kI Z: 0- 32 SL REDOREDFGN T $W.000ES. REQUIRED FOR FINALAFPflOVAL `\ V=VERY G-GRAVELLY S•GAND L-IOGAN 9=SILT C=C4Y Eap%TRFMELV R=RWT$ AFFQLATIGIAPPROVEGISSUEOMV DATE INGpECTOR&C-01ATWE DATE AFPLIfATION EVTPATION TE 'Y•\ ' REVI$EO tN'.'A THIS FOTEM MAY BE NE)AND AVAILABLE FOR PUBLIC VMW ON THE MASON COIMttVRMSRE - DESIGN FORM—PAGE ONE Assessor's Parcel Number: 3 2 0 2 1 — 5 8 — 0 4 0 5 9 A design will be reviewed when 3 copies of each of the following are submitted: a Completed design form that has been signed and dated. "Scaled layout sketch.including all applicable items on checklist "Scaled plot plan. including all applicable items on checklist. v Cross-section sketch-including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site..Maximum papersize: 11"X17" �n u lP-AARCELIDENTIFICATION Permit N 1OZumber: SWG ofT)7 Designer's Name: Arrow Septic Designs, Inc Applicant's Name: Empire Home Construction Designer's Phone Number: (360)898-2255 P.O. Box 247 171 E Vtmcrest Dr Mailing Address: Designer's Address: Kelso WA SU26 Union, WA 9MW Cit State Zip Cit State Zip DESIGN:PARAMETERS Treatment Device ❑Glendon Biofilter 0 Send Film, ❑Mound ❑Sand Lined Drainfield ❑Recirculating Filter,Type: �/ m Aereble Unit Mainevadcl NuWas9r BNR-5W O Disinfection Unit MekelModcl Other: Drainfield Type 0 Gravity efPressure R(Treneh ❑Bed ❑Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 3 SchedWe/Claas 40 Daily Flow:Operating Capacity 270 gpd Length 50 IT Daily Flow:Design Flow 360 gpd. . Diameter 1.25 in Septic Tank Capacity(working) Nu Water BNR-600 gal Number 4 Receiving Soil Type(1-6) 4 Separation 5 ft Receiving Soil Appl.Rate 0.6 gpd/fe Orifices Required Primary Aces 600 Flaotal Number of Orifices 40 Designed Primary Area 600 ft, Diameter 3/16 in Designed Reserve Area 600 ftt Spacing 60 in TrenchBed Width 3 ft Manifold Trench/Bed Length 200 It Schedule/Class 40 Elevation Measurements Length header ft Original Drainfield Area Slope 3 % Diameter 1.25 in New Slope,If Altered 3 % Preferred manifold configuration used? R(Yes ONo Depthof Excavmion UPslore 12 in Transport Pipe from Original Grade ps..,lope i t in Schedule/Class 40 Designed Vertical Separation 12+ in Length 40 It Gmvelless Chambers Required? ❑Yes ONo 1190ptional Diameter 2 in Pump Required? Id Yes 17 No Dosing and Pump Chamber Pump/Siphon Specifications Number ofdosesrday 4 Diff.in Elevation Berween Pump&Uppermost Orifice B ft Dore quantity 90 gal Dminfleld Squirt Heighf/Selmc dRwidual(head) 2 R Camber Capacity(flood) t,Wp gal Uppermost Orifice g(Higher ❑Lower than Pump Shutoff ump controls:Please check those required. Capacity Q Total Pressure Head 23.6 gym EfTimer GdElapse Meter RrEvent Counter Calculated I Total Pressure Heed 11.71 ft If Timer: Paragon 2 minutes pump off 6 boors Comments APPROVED MAY 14 20A ,VpuTo MASON COUNTY ENVIRONMENTAL HEALTH RET DESIGN FORM—PAGE TWO Assessor's Parcel Number:3 2 0 2 1 — 5 5 — 0 4 0 5 0 Permit Number: SWG DESIGN CHECKLISTS Mpropmed t Plan Scaled Layout Sketch Cross-Section Sketch e locations 19 Drainfield orientation and layout Reference depth from original grade: s Rf Trench/bed dimensions and 51 Septic tank y lines critical distances within layout IZ Drainfield cover Ed D-Box/Valve box locations Reference depth from original grade and proposed wells Septic tank/pump chamber and restrictive strata: 100 ft of property Pements to cuts,banks,and locations � Laterals,trenched,top and surface water and critical areas 0 Observation port location ❑ bottom drain collector ❑ Location and orientation of E6 Cleantim location ❑ Sand augmentation curtain drain and all absorption 56 Manifold placement components Orifice placement Other cross-section detail: Rf Observation parts/cleanouts III Location and dimension of E6 Lateral placement with distance primary system and reserve area to edge of bed Other Information m Buildings R1 Audible/vis referenced Yes No it Direction of slope indicator E6 Scale of d on scale E6 ❑ Design staked out R1 Waterlines bar ❑ 9 Recorded Notices attached Id Roads,easements,driveways, y. ❑ fie{waiver(s)attached Parking , r' �, 0 ❑ Pump curve attached ❑ fii(Evaluation of failure Id North arrow and scale drawing 51 oJt 9. Non-residential justification shown on scale bar I PAULA JOY JOMNaON't ❑ 9f Waste strength p ❑ Rf Flow DESIGN APPROVAL The undersigned designer must b inst 11 at time of installation t�Yes ❑ No 04 411�'t `- `f -I,s z� Signature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local on-site regulations: 0 iW�,Y/ Y✓1/1 1 Environmental Heap Specialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions ofilesign approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site.Updated Date: 17172015 i ___________ -----------8O 1S3BOIIIH 3.-___.__________________.a a l...� I I I APPROVED j MAY 14 2024 MASON COUNTY ENVIRONMENTAL HEALTH '0E RET 6iF A'c 30'Omtl'E as i t I C1 i. ' SemoeE 6 � m @ I I i I Us 5 W L �- ]eTE 5p eG]Yo i a I I I msu I I Sllbx\QG� sy I ® m.______________ `J OOMMNNAI____ m ��E �ti' ra 10 3c ao -C -C �1J-�1 E g �cl 30" SL xeocts,3C'-�2 i Mo i �,E,u S i I'C -a �• rnrN;iet; s; _y �ca�l, �,=�20®�5'. s � err �o iui si t4r 11,mm. u] 4 #kIA :"v Lo bs APPROVED MAY 14 2024 km MASON COUNTY ENVIRONMENTAL H OAlldio-visual AlWtO RET. , S .. O2 Cleanout Or ontiy necdzd P L.' . a00 Ga/io^? e-T*ash tars j NCOd�D PAVLA JOY JOMN60NIN •. O4 NuWater BNR-500 ATU Tars C 1,000 Gaieor?gyp Chamber O6 Valve Control Box �L� t py tipw�•eLy�•Q3 I.Y-�i°T•/�_. �nkS �,W J" 3 _ scaae. PAOIA JOYY JONNSON . ' r gilt' w APPROVE® MAY 14 2024 MASON COUNTY ENVIRONMENTAL NEALTh RET 36 —scREg ON CAP scas� :.t= t ` f24- As DEGREE ELBOW .END OF Nose (Rypfatheea L/ . DZTC� Fvc we Aafi bmmal co*to Vt DETAIL PVC PA 4m<b91 'W IN blto 8ded r•r vsra pQT dada amput 4m am- -mbee m ObSaYLbOb pbKpgla GlbeTmhamm. NOTE, CLEANODT TO BE FROM 0 TO 6 aopipe=Ybermoved. IN'CEZ5 BELOW PIVXSEED GRADE. W.cf¢ in CAME.a mdofetlttm MARK ENDS WITH RED". CLEAR ODT Imx k=wbc=mwmdmamdc REQIIT_RED AT E= OF EACH LATERAL• . 4 1r Length Length Orifice # Distance from Distance from Lateral# (In. Ft. S acin Orifices Feeder Line(In. Cleanout(In. 1 600 50 60 10 30 30 2 600 50 60 10 30 � 3 600 50 60 10 30 4 600 50 60 10 30 30 Total Lateral Length 200 Total#Orifices 40 GPM= 23.6 Dynamic Head calculations Selected residual pressure: 2 ft. Length(Ft) #Orifices Transport Pipe 40 40 0.40 ft. Feeder Total Lateral Line Length Lateral#1 50 2 52 10 0.29 fl. Lateral#2 50 7 57 10 0.31 ft. Lateral#3 50 12 62 10 0.34 ft. Lateral#4 50 -17 67 10 0.37 ft. Total Elevation Lift 8.00 ft. Total Dynamic Head APPROVED 11.71 ft. MAY 14 2024 MASON COUNTY ENVIRONMENTAL HEALTH RET swim LW Wr1H GASTIGHT SEAL THREAGEG umbH ss•CIA116TER . AOOM R OM \ geRVICE 601110RAW _ VALVE. c _ . Fill=SO= i —ETC 011/1VYIBD TAM @1lIWEMCr nrortaoe MRt et'rroM VALVE• WW WA7M ALMY LEVEL movena)r 1101WAL OFF LEVEL yYCRI(mO VOLUME FL FL"TI Port YOII mnm • GNOLOO O NAIP . y O• CHECK VALVE 8 Ir i SEDNMM [n':It OmvfnwqxlAL sroo��s f PAUtA JOY JpHN50N (Typ1f:ALl Septic Tanks must meet standards required by WAC chapter 24�6-272C and FIGURE.2` manufacturer must be on Dept of Health list of registered sewage tanks. S WA rww P.Mic Lion#337-022 Page 35 of65 7 Brame comtruaion available(239 series) ems` High head verrion available(145 mries) • Double shaft seat versionsavailabie fminided protection on models 140/145. Flow-Mate Formorc infonnatioM me Techniml Data Sheets FM2782 FM2783. In high head dewatenng or effluent applications where pumping .I aavNuoeayse performance is critical, this robust familyofpumpsislmownforreliability, i durability and performance. These l pumps are especially suited for harsh emrironmerns.ZmrLLWs cool von design and corrosiemresistam,powder coated epoxy finish add up to a tong-lasting, troubLe-free product. MPLICATION9: �. a STEP or.mite applications • Watertransfer 6• • Light commercial dewananng SPECIFICATIONS: 1-1/2-NPT discharge sslayyyat�aaAppp���E�������rIII���-IIOss�a��A • 112 HP through l HP Available in auromatic or nonautomatic OOOMMMIIIWWW III',LLLLLLIII�IN��IIISSSIII Model 137,139,140:1/2-(12 mm)spherial solids a apae ty with von"impeller • Model 145:3/4•(19 mm)spherical solids capacity with vcnexinnim"r jC f PUMP PENFO M 10E CURVE �• MODE 161 61/153 Dose-MatevK RWI`1ALE14 N This is ourfastestgrowing line of effluent N w ' pumps.The 150 series is truly a workhorse M designed for reliability under extreme 12 conditions in an effluent environment. Is 250series pump curves cover a wide range c 'N of applications. They are well suited to N ro applications with low pressure pipe(LPP) b e sS isi and enhanced flow STEP systems.Zoeller's y cool von design and corrosion-resistant r a� powder coated epoxy finish. in addition to the hermetically sealed.oft-filled motor rs and non-clogging vortex impelLer add up w a long-tasting,trouble-free product. 10 MPIJCATION9: STEP or onsite appLicadom MLADEUMMIEUSA ° to w ao N m N N • Light commerciaLdewatering figgIIMII08OII111 GILIONS u�r ere-1/2- lox9: FF 01•a • 1-1/2•NPT discharge • 3110 HP through 112 HP MAY 14 2024 Available in nonautomatic or with a variable level piggyback mechaniaL swmh MASON COUNTY ENVIRONMENTAL HEALTH 112"(12 mm)spherical solids capacity with vortex RET thermoplastic impeller For more information,see Technical Data Sheet FM2784. m AUrighareserved. ZOELLERPUMPCO. 1502-nS-2T311 800.928-7867I oelbrrpuralmom 9 isva�a uvroamm �'N 3NJS fi�tG99 'A9E; -Xtld 899t[S9 m9Ei '3NONd � 'N't30 MN96 tlM'ON(lOtl'J 31LLtl8 L60£XO8 O'd yse�1009 009 EL9 �NI JN11:133NIJN3 >G IIIffi $� ht iW 4��x111`3 53 V �t 6. kTy Yy�y' HIM g s OWN 3 S£F�FY Raw at 1p 'a * APPROVLlb P _ MAY 14 2024 MASON COUNTY ENVIRONMENTALHEALT� ; yqa s RET H qq ffi4Yil '§'Y s ? IY py ppppR `€ .P 1 9 e 04 8 4 H a E 5ityiNui xK �- Pala a � nBn2V €x i RuiH tr s7 €S S-S ' IXNL PoRIAERATOR i RISERS 10M LID velr lml XIa00(1YP1 1•wD RYq 12'PVCI IAPSTIC iae•MPX. NRI.dE 4' SfXILIRINO T a REDOCER STEE i I 1•WCSWDGE •. 1T aENCg1 LINE I, TRASH CRAMBER I DIDElalt CRAEIBER CWWBER CLARIRIER I pPERO.TNG GPALRY. 1]GLLONS OPEFATNG G➢ACIfY:6RI GPLLON3 FLOOD WACnY:�9r aALLONs FLOOD WACRY:OBa GPLL°NS 1lOGNLONS Rp'1D:1%IML.i �• 1'X iR' TEE APPROVED MAY 14 2024 DIFPgs3Ra TMK r PAPPLATO TANK WALL p e, SW WE PENRN fit iSiN'ER MNE.FREE NAIVE 8011 ORG PAOTED SAND OVER STONY SOIL INBTALIATN]N dBTRUCB0N8 1)Excavate Wnk hole with venicel wa9a W i fGol larger Than rank on all apes. 2)RD rn of We is"y.install a•of romped Sena&level '�— sS W)3IrsnIl vuaWes. osMer of hde,kwpingl8 void sparo Dn r-------'r----- —, p.Rgiarve) xxoam 4)As tank is filling w water,w1 in v space w romped I 1Y Tppd gnnular(sanay)Sailhef oi large erlmpsofplena I it Ul I E)Inular test of s l f rre&flare risers W ed day.wiN i I I i i 1 6)Perform as tertigh 1 6)Perform watertightness lest in field as requires DY lapl I I I )Unsa a l it RlsHl ])tjs approval W badaill,carefulty bggtfill with nairve soils over tap of tank. I TRa3waue� i I rc�ESiEB I IGe6� 8)Final gnaw the surface W awW chenHling surfaro L_ _-----L— _ ------ _--� Ve ar Iowan nnk TOP VIM _ w AEROBIC TREATMENT TANK DETAIL FOR NUWATER BNR-500 TREATMENT UNIT ENVIRO-FLO, INC. "SE° 3/01/12 P Oa BOX 3211661 Fio .M5 2 1" - 1.4 ft. (877)836-8476 ,,, 1 ,nat 161ax ww.v n ' o. C6 otl0 AgoNu Wa!t r m e -P Imo, PARTS UST NuWater NR Assembly Diagram A DUAL PORTAFRATOR W POLY DIFFUSER SAR a, S.SR'RNSSER WWI Ct PS 12) N.1`PN(312 SECTION) C,SWBARSEDAIlAPTORR V NPTQ! O.1`SLIPCAP �/� O,R`SUP%1YCNPTAOAPTOR P.ire CL FTI EARPVCNOSE(ODKALS" `PFROV E r BR .X 1 I N"9USMNG I3) D.1 Y PVC PIPE(BY INSTALLERI F.lZWELSCANM R,VP PIPE(BYINSTALLER) MAY 14 2024 S. M' PIPE(BYINSTALLER) /� W'ELSOBOOW(B) T.Ire�BAnBEO ADAProR TD VVIAA6gN COUNTY ENVIRCNMEN LHEA �l7\Vp 1.zz PBUSFIING U.IZS EET K W NPT SUWNGM RET J.Y'SANITARYTEE v vY FVC COUPLER I?) K,P PVC CROSS WS COUPLER(BY INSTALLER; :.1`COUPLER(BY INSTALLER) Revised 2/25/12 lDolym Q,ucveu septic NuWater BNR Pretreatment u TION&MA1nt'fENANCE .1. Pressure Drstnbuhoa Systems ,,;Y,,, 1'.;�:Q � PAULA JOY JOMNSON.?y 1 Install Laterals with contour of the ground 2. install trench bottoms level. 3. Install locator tape or rebar at each end of all drainfield laterals. 4 Install observation ports as indicated on the plot plan. One required at distal end of each lateral in drainfield with bottom extending to the draimock/native soil interface. Glue `"I^to bottom so Observation Port cannotbe veasily removed from ground. Install removable capon top of dry weather it conditions; any soil smearing must be 5. Install drainfield during dry eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals(cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7 Install audio/visual high water level alarm. Redundant Off switch not required. 8. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 9. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock,(do not glue),after pressure test and Environmental Health Dept. approval,turn orifices down(6 o'clock)and glue laterals to manifold Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 10.Filter fabric required over drain rock prior to back filling. if the drain rock extends above natural grade,run the filter fabric at least 2 inches down the trench wall. 11.Encase all water lines within 10' of drainfield and under any driveway/parking areas. 12. Divert all storm water runoff away from on-site sewage system 13.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 14.No vehicular traffic over drainfield area IS.Inspect floats,clean filters,and test high water level alarm every 6-12 months as needed. 16.All materials and workmanship must meet County and State regulations. 17. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void 18.All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 19.All pressure systems with a pump chamber outlet higher than the drainfield must have a 1/8"hole drilled in the discharge pipe above the pump to prevent siphoning. 20.All transport lines under driveways or parking areas must be encased to prevent crushing. 21.Homeowner is responsible for all property lines. installer to 22. Please Note: When you begin using Your septic system,contact your septic discuss setting up a schedule for your required Operation&Maintenance on your NuWater pretreatment system. APPROVED MAY 14 2024 lvO� �p MASON COUNTY ENVIRONMENTAL HEALTH RET