Loading...
HomeMy WebLinkAboutCOM2007-00060 Building 3 Final Sign Shop - COM Permit / Conditions - 1/5/2010 • MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 edar P.O. Box 186 Phone: (360)427-9670,ext.352 IP4 Shelton, WA 98584 COMMERCIAL BUILDING PERMIT COM2007-00060 OWNER: MASON COUNTY PUBLIC WORKS RECEIVED: 5/25/2007 CONTRACTOR: ROGNLIN'S, INC. LICENSE: ROGNL**342LF EXP: 8/1/2009 ISSUED: 9/21/2007 SITE ADDRESS: 100 W PUBLIC WORKS DR BLDG E SHELTON EXPIRES: 3/21/2008 PARCEL NUMBER: 420021000010 LEGAL DESCRIPTION: PCL 2 OF BLA 06-72 PROJECT DESCRIPTION: DIRECTIONS TO SITE: SIGN SHOP - Building 3 Intersection of Hwy 101 & Hwy 102. General Information Construction&Occupancy Information No.of Units: Type of Constr.: II Type of Use: sign shop Insp.Area:Type of Work: NEW Fire Dist.: 16 No. of Bathrooms: 1 Occ. Group: F1/S2 Valuation: $ 404,147.44 No.of Stories: 1 Occ. Load: 28 Building Height: 22 Pre-Manufactured Unit Information Square Footage Information Make: Length: Lot Size: cov stg: 1,232 Model: Width: Building: 6,884 Year: Serial No.: Basement: Parking Spaces: Setback Information Shoreline&Planning Information Front: Ft. Shoreline: Ft. Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.: Side 1: Ft. SEPA?: Comp. Plan Desig.: Side 2: Ft. Fire Protection System Information Auto Fire Alarm System?: Emergency Key Box?: Standpipe?: Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?: Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?: COM2007-00060 Please refer to the following pages for conditions of this permit. 1 of 8 Plumbing Fixtures Mechanical Fixtures FEES Type, Qty. Type Qty. Type By Date Amount Receipt Lavatories 1 Unit Heater 1 EH Plan Review TIn/ siA/,>nn7 T.75 nn C1,nn7nn Water Closets(Toilets) 1 Ventilation Fan 1 Plan Check Fee ni r` 7/1,A/7nn7 T,1 75R 1a C1gnn7nn Water Heaters 1 Non-Res. Energy Code ni r. 7/1Annn7 4tad nn R17nn7nn Drinking Fountain 1 UFC Plan Check Fee ni r 7/1,A/7nn7 -ZA7R n7 C1 gnn7nn Building State Fee ni r 7/1'A/7nn7 u cm C17nn7nn Building Permit Fee ni r. 7H,A/9nn7 .50 7n1 7r, C19nn7nn Mechanical Fee ni r 7/1'3/7nn7 T.7d 75 C17nn7nn Mechanical Base Fee ni r. 7/1 4/7nn7 An C1,2nn7nn Plumbing Fee ni r. 7/1A/7nn7 -in An C17nn7nn Plumbing Base Fee ni r. 7/1'119nn7 nn c1')nn7nn Total $5,581.81 CASE NOTES FOR COM2007-00060 CONDITIONS FOR COM2007-00060 COM2007-00060 2 of 8 1) 1. A stormwater site plan with low impact development features such as pervious paving, rain garden infiltration and native vegetation, will be created and implemented prior to development, clearing, grading or construction of any portion of the proposed development. 2. The proposal shall be required to control erosion during construction. Removal of vegetation should be minimized and any areas disturbed should be restored to prevent erosion and other environmental impacts. 3. Site is within a portion of the county designated as Class II Critical Aquifer Recharge Area, under Critical Aquifer Recharge Area Chapter 17.01.080 of the Mason County Resource Ordinance. All provisions of the CARA chapter shall be followed including obtaining a Mason Environmental Permit, application of Best Management Practices on site, and an engineered stormwater site plan in compliance with Ecology's stormwater, water quality, Hazardous Waste, wetland and solid waste program BMP, and BMPs from the departments of Health, Agriculture, Transportation and State Conservation District Office. 4. Project applicant shall develop in compliance with Geotechnical report completed for this site by Aspect Consulting dated January 22, 2007 and updated March 26, 2007. 5. In accordance with discussion between Squaxin Tribe and Mason County at meeting on April 9 2007, Mason County and the Public Works department propose to work with the Squaxin Indian Tribe to craft a Memorandum of Understanding between the two governments, relating to proposed project measures, which further reduce impact to the aquifer beyond that of usual development impact through a series of additional measures. These proposed measures and the memorandum are being developed, but would include such measures as low impact development, and minimizing water withdrawal through conservation measures, pervious pavement, stormwater infiltration, rain gardens and native vegetation, and proposing to h ok u "to City of Shelton water when it becomes available. Although this proposed Memorandum of Understanding is still under way as of this dat it�ise understanding of the parties that it shall be completed and in place prior to the issuance of building permits for this project.x 2) Owner/Agen is re7ponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. I X 1' 3) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF USE OfZ�f�C r PANCY WOULD RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x 4) Changes to appr ved bu)lding plans that affect compliance to the current Washington State Energy Code (WSEC), ventilation and Indoor Air Quality Code ( I Q) ilding/Plumbing/Mechanical Codes and/or Mason County Regulations shall be approved prior to construction. X �- 5) Any changes in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are removed, ap pval will not be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected be on County Building Department prior to any further inspections being performed or approvals granted. X 6) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance wfth the iptgrnational codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason C u tSr �it inA Ospector shall be made prior to requesting additional inspections. COM2007-00060 3 of 8 7) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant w" h Mas County ordinances and building regulations. X 8) A separate p�P';_'_w s required for the fire alarm system, application must be made an the permit issued prior to installation. The system must be NFPA 72 coan ully monitored by a UL certifed monitoring Co. Xo" A separate permit i required for the fire sprinkler system, application must be made and the permit issued prior to installation. The system must be NFPA 13 co pli X 3A20BC fire extinguis rs are required to be installed, the maximum travel distance in any direction is 75 feet. The unit is required to be mounted no more than inc abov the floor to the top of the unit. X A key box is required to be installed on the e r of ' building per 2003 IFC chapter 5 section 506. Please contact the local fire district for information and inspection. X �_.r�� Fire protection equipement shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves or fire detec-4i6 , suppression or control elements shall be identified for use of the fire department. Approved signs required to identify fire protection equ t n equipement location, shall be constructed of durable materials, permanently installed and readily visible. X 9) PER TITLE 14 MASON COUNTY BUILDING CODE-CHAPTER 14.17, STANDARDS FOR FIRE APPARATUS ACCESS ROADS- 14.17.110: A fire apparatus access road in excess of 14% grade and more than 150'to new residential or commercial structures will require an automatic fire sprinkler system i 'called. Contact the Mason County Fire Marshal at(360)427-9670, extension 273, for further information. x 10) The use, handling and storage of hazardous materials or flammabl fl cpmbfistible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 11) The approval of this project is subject to the recommendations and specifications outlined in the attachedF otechnical report or assessment. Structures and/or land modifications (grading, cuts, fills, etc.) required in the geotechnical report/ass qt, a require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X 12) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which i , posed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which a t your project. X COM2007-00060 4 of 8 13) All approved plans are required to be on-site for inspection purposes. If inspection is called for and plans are t on site, Approval WILL NOT be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be char d nct�bllected by the Mason County Building Department prior to any further inspections being performed or approvals granted. X L 14) All property lines shall be clearly identified at the time of foundation inspection. X 15) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The pe n si ning this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 16) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-098 he pperson signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 17) Retaining walls needed to support a surcharge such as structur s oadsl r to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 18) The approved site plan is required to be on-site for inspection purposes. If inspection is called for and the site plan is not on site, Approval WILL NOT be granted. In adjdition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by the Mason County Building Dep ent iiir to any further inspections being performed or approvals granted. X 19) Recyclable materials & Solid Waste Storage: Space shall be provided for the storage of recycled materials and solid waste. The storage area shall be designed to rr t the ne ds of the occupancy, efficiency of pick-up, and shall be available to occupants and haulers.X 20) International Buildig Code CHAPTER 17: IN ADDITION TO THE INSPECTION REQUIRED IN IBC, SECTION 109, THE OWNER OR THE ENGINEER OR ARCHITECT OF RECORD ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS WHO SHALL PROVIDE INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF WORK LISTED UNDER CHAPTER 17. THE SPECIAL INSPECTORS DUE I? & rONSIBILITIES SHALL BE AS SPECIFIED IN CHAPTER 17. X ` / 21) Washington State Energy Code Compliance is approved as follows: ENVELOPE: Prescriptive, Table 13-1. Electric- Rooms 301 & 303, Other fuels rooms 304, 305, 306, 307, & 308. All other rooms shall be unheated. The building envelope shall be insulated as follows: Wall insulation R-19, Ceiling insulation R-30, slab insulation min R-10, windows U-.40 or less (U-.45 u-factor in rooms heated by other than electric fuels), doors U-.60 or less. All insulation shall be installed to the full depth of required R-value. Evidence of u-factor for windows and doors shall be available for inspection. Slab insulation shall be insulated around the entire perimeter of the heated space. MECHANICAL SYSTEM: Approved as shown on approved building plans. LIGHTING: Approved as shown app ved building plans. X COM2007-00060 5 of 8 22) The mechanical system for which energy consumption, performance, or mode of operation are regulated by the 2001 Washington State Energy Code (WSEC) and Ventilation And Indoor Air Quality Code (VIAQ) shall be tested to ensure that control devices, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Drawings and notes shall require commissioning in accordance with WSEC section 1416.4. Lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with the approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing not 'shall require commissioning in accordance with WSEC 1513.7. X �1 23) This project is approved with a fire-sprinkler and monitored alarm system installed in accordance to Fire Marshal approval. The sprinkler system shall be installed and ipspected prior to the framing inspection performed by the Mason County Building Dept. X ' 24) Deferred submittal has been approved as follows: 1) Building structural calculations, prepared by the structure engineer, AND final foundation design, prepared by PCS Structural Solutions, shall be submitted and approved by the Mason County Building Department prior to foundation inspection requests. 2) Special Inspectio uthorizetion shall be submitted and approved prior to inspection requests. X 25) Accessible route within the site shall be provided from public transportation stops, accessible parking and accessible passenger loading zones. At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces on the same site. An accessible route shall be provided to each portion of the building and to accessible building entrances. All accessible elements shall be identified by the International Symbol of Accessiblity as specified in the 2003 International Building Code, Section 1110. At least 50% of all entrances shall be accessible to persons with disabilities. Where provided, thresholds at doorways shall be 1/2-inch max. height. Changes in ighX greater than 1/2-inch in height shall shall be ramped. x b COM2007-00060 6 of 8 26) 1. A stormwater site plan with low impact development features such as pervious paving, rain garden infiltration and native vegetation, wiN be created and implemented prior to development, clearing, grading or construction of any portion of the proposed development. 2. The proposal shall be required to control erosion during construction. Removal of vegetation should be minimized and any areas disturbed should be restored to prevent erosion and other environmental impacts. 3. Site is within a portion of the county designated as Class II Critical Aquifer Recharge Area, under Critical Aquifer Recharge Area Chapter 17.01.080 of the Mason County Resource Ordinance. All provisions of the CARA chapter shall be followed including obtaining a Mason Environmental Permit, application of Best Management Practices on site, and an engineered stormwater site plan in compliance with Ecology's stormwater, water quality, Hazardous Waste, wetland and solid waste program BMP, and BMPs from the departments of Health, Agriculture, Transportation and State Conservation District Office. 4. Project applicant shall develop in compliance with Geotechnical report completed for this site by Aspect Consulting dated January 22, 2007 and updated March 26, 2007. 5. Subject to provisions of intergovernental agreement between Mason County and Squaxin Tribe. 27) 'Owner or engineer or architect of record acting as the owners's agent shall employ a n independent civil engineer, licensed in the state of Washington -to inspect the installed stormwater features for consistency with the attached stormwater plans and BMPs. That civil engineer shall submit written statements to the Mason County Pla 'ng partment indicating that the inspections(s) have been made, and that the final installation is consistent with the plans. x 28) This parcel is locate in)a smoke management zone. Please contact a fire warden at(360)427-9670 ext. 459 for further information. X —�' 29) Retaining walls needed to support a surcharge such as structuress, rjto support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X - ` � 30) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structu meet the setback conditions listed. X C .f This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress ins ection.The owner or a agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property an ucture for review d inspection. if, OWN ER OR AGENT: DATE: COM2007-00060 7 of 8 Fr CONCRETE MECHANICAL gy L MANUFACTURED HOME Footings (Setbacks DateGasPlpfng Ribbons interior Date By Interior-Date By Dale By Exterior Date By Exterior-Date B Set-up Point Load I Isolated Footings INSULATION Data By Date By Data SLAB INSULATION By f1RE DEPARTMENT Foundation Walls Floors Date By Date By Data By DECKS FRAMING Walls Date By Date By Data By PROPANE TANKS PLUMBING vault Data lay Data By OTHER Groundwork Attic Date By Date By Type: Date By D.W.v DRYWALL Type: Int Brace Wall irate By -v Date By Date By FINAL INSPECTION _ 2 Water Line Firs Soperatlon 8 Bate By Date By Date By Pass or Request Inspect. ° Type of nsp. Fail Date Date Done By Comments Z Dr L-01, o o CD th .. .. ._. ..... Wit 0 IA i � J Spy ' go 1 n�11 r CONCRETE MECHANICALCei arm MANUFACTURED HOME N CA o Date �/410$ By O Footin • ack Gas Piping Ribbons z o Interior Date By Interior-Date By Date By 0 CF)o Exterior Date By Exterior-Date B Set- 0 Point load l Isolated Footings INSULATION Date By z BG 1 SLAB INSULATION Date By Data By FIRE DEPARTMENT Foundation Walls C Floors Date BY C Date, By Data BY DECKS ca FRAMING walls Date By n Date It Ito 6,6/ By LZI( Data By PROPANE TANKS PLUMBING vault Date By O Date By Groundwork wo ii n, D� Attic OTHER Date By Date By Type.Data By o.w.v DRYWALL Type. O Date B l Int.Brace Wall Date Byic y Date By N 6 FINAL INSPECTION O Water Line Fire Soperation O Date By 1,. Date By Date I j IU By �Q�C_ 4 O Pass or Request Inspect. CD Type of Insp. Fail Date Date Done By Comments c -4 o -ems`u� 14, -7 36 10c" ay— -5 09 ai 1,41C/ I,5 A�A1te is OV- As 13A C"-fr,c(cre- t„J, t ,p1� o �,rurjrt� 0 , Z)w v e. s S 61161o . w z b �cs'C .J— - u 1,0 cl i"n tJJ,l k;- vi ►Ili CVA IY. co oD v ROO k 4sz r� /00 &q " s'9 N slid� Building Permit # MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 106 a This structure has been inspected b Mason Count Building Department P Y Y 9 p and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance pre) 1 I <2N ,'- del- L21focluraP ob5exyahpnn vita �b' &&e rloAthn You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK *,Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department g L6 Date �Il �I Inspector moos NOT MOV THINom, T ' ,*w TAC Systems DATE 12/4108 � PAGE 3 UNIT EF-302 AIR MOVING EQUIPMENT DATA AREA O�D 4. 2 SERVED: BLDG 3 MAINTNANCE FAN EF-302 EQUIPMENT MFG. GREENHECK EQUIP. LOCATION ROOF MODEL LBP-14-3-X TYPE/SIZE SERIAL NUMBER 1136 1997 0806 FAN DATA SPECIFIED ACTUAL FAN SHEAVE 5"O.D. TOTAL CFM-FAN 1800 1792 FAN SHAFT 3/4" TOTAL CFM-OUTLET 1800 1792 BELT SIZE 41-420R FAN RPM 1118 1080 QUANTITY 1 ESP 0.38 0.06 SHAFT C/C 14 1/4" SUCTION SP 0.05 DISCHARGE SP 0.01 MOTOR SHEAVE VP34S MOTOR SHAFT 1/2" SHEAVE ADJ. 1/2 TO MOTOR DATA MOTOR MFG. MARATHON SPECIFIED ACTUAL MOTOR HP 1/3 VOLTAGE 115 119 SERVICE FACTOR 1.15 AMPERAGE 6.6 6.47 PHASE/Hz 1/60 BHP HEATER SIZE/RATING THERMALLY PROTECTED MOTOR RPM 1725 1755 MOTOR FRAME# 56Z I ISPEED DIFFUSER AND GRILLE TEST SHEET AREA SERVED NO. CODE SIZE AK DESIGN INITIAL FINAL FPM CFM FPM CFM FPM CFM 302 E1 OPNG 16X12 1.26 714 900 492 619 661 832 302 E2 OPNG 16X12 1.26 714 900 499 628 762 960 1800 1247 1792 REMARKS: FORM 2A