PRE-APPLICATION CONFERENCE REQUEST FORM
The purpose of the pre-submission conference is to identify and/or eliminate as many potential problems as
possible in order for the project to be processed without delay. Representatives for the Fire Marshal's Office, Building
Department, Environmental Health, Planning, and Public Works Departments may attend the meeting to discuss rules
and regulations applicable to the proposed project. Topics covered during the meeting will include the comprehensive
plan, shoreline program, zoning, availability of sewer and potable water, development concepts, building construction,
fire protection and life safety concerns of the proposed project. The pre-submission conference will be most informative
when you provide accurate and detailed information on the Pre-Application Conference Application Form and the site
plan. Applications will be accepted when all information is received and deemed complete.
Pre-Application Conferences are held every Wednesday and last up to one hour. To schedule a meeting
complete the applications and return with 6 copies of the detailed site plan, by 3:00 PM on the Wednesday two weeks
prior to the proposed meeting.
1. Pre-Application/Community Services 2. Environmental Health
615 W. Alder St 415 N 5 h
Shelton,WA 98584 Shelton,WA 98584
360.427.9670 ext. 352 360.427.9670 ext. 400
Check amount: $255.00 Check amount: $205.00
BOTH CHECKS MADE PAYABLE: MASON COUNTY TREASURER
Applicant: Site Plan
Name: Tractor Supply Company
Submit 6 copies
Mailing Address: 5401 Virginia Way, Brentwood,TN 37027 Include the following information
Daytime Telephone: (615)440-4742 Fax: (615)484-4742 ,Zr Indicate Scale and North Arrow
Email address: syounger@tractorsupply.com Property line dimensions,easements,
and right-of-ways.
Representative:
Name: Pedro DeGuzman, PE - Terraforma Design Group, Inc. The location proposed of all existing and
structures.Include square
Mailing Address: 5027 51 st Avenue SW, Seattle, WA 98136 footage of existing and proposed
structures.
Daytime Telephone: (206)923-0590 Fax: ----
Setback distance,in feet from all
Email address: pedro(a-)terraformadesigngroup.com property lines and structures.
Parcel Number: (12 digits) 42002 - 44 - 00010 d Existing and proposed road access to
and from the site.
Description of Project:
Include: 1) Square footage of structure,2) Use of building and rooms (i.e. Parking sites
office,warehouse, restaurant, storage, etc), 3) Occupancy classification per 2( Location of on-site sewage tanks and
drainfields.
IBC, Section 302.1, and construction type. 4)Provide two sets of plans,if
Location of drinking water supply.
available. Use separate sheet if necessary Include location on the proposed site
Proposed Farm& Feed Store with associated retail area, storage&office space and surrounding parcels.water service in Hwy 101
Main Building Footage=21,930 sf, Separate Detached Hay Barn=2000 sf Steep bluffs,wetlands,streams,and
Occupancy= M bodies of water None known
Construction Type= 1113 Zf Location of fire hydrants and
emergency vehicle access roads,
Proposed outdoor storage&display areas, parking and landscaping. including grade.
(2)existing mini-storage bldgs,drives, grass areas to be cleared.
Surface and storm water run-off routes.
Has the project been discussed during a previous Pre-Application Conference: If yes,please indicate date.
No
Will the building have employees? If yes, how many? 8-12 full time employees
What is the water availability of the proposed project? If there is an existing well, what is the name of the
system? Existing water main within west side of Highway 101.
What is planned for the on-site sewage system? If you are proposing a new on-site system provide detail on the
required site plan. We are trying to confirm possible sewer availability with the City of Shelton. If unavailable,
en a new septic system will be proposed within the north end of the site.
ADDITIONAL INFORMATION: -�d - -
APPLICABLE BUILDING CODES
Code changes are on a 3 vear cvcle: effective in July of that Darticular vear.
Date of Conference: LD _ I _ ' (-,o Time of Conference: I . '�0
Location of Conference:❑ 615 W.Alder St,Shelton, WA Planner-
C� ext.
��415 N. 6'Street,Shelton, WA v
e� Cam,, -�m�► l .• �-o✓�
A MASON COUNTY l �b
DEPARTMENT OF COMMUNITY DEVELOPMENT
Building Divisionedt�
Mason County Bldg. 8, 615 West Alder Street, Shelton, WA 98584
1854 www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269
MASON COUNTY PRE-SUBMISSION CONFERENCE NOTE,$�W �OU
• BUILDING DEPARTMENT REPRESENTATIVE: (360) 427-9670 ext. 281
E-Mail: tw@co.mason.wa.us F
• DATE: June 1St, 2016 f0*111 Y
IL
• PROJECT/ PROJECT TRACKING NUMBER: PAR2016-00026 of
• PROJECT REPRESENTATIVE (S): Tractor Supply Company- Pedro DeGuzman, PE
DESCRIPTION & SIZE OF PROJECT/OCCUPANCY CLASSIFICATION & USE: Proposed Farm & Feed Store
with associated retail area, storage & office space, main building footage= 21,930, separate detached Hay
Barn= 2,000 sq ft, Occupancy= M, Construction Type= !g, proposed outdoor storage & display areas,
parking and landscaping. 2 existing mini-storage bldgs, drives, grass areas to be cleared.
ATTENTION: BUILDING CODES ARE TO BE UPDATED TO
THE 2015 CODES JULY 15 2016
Complete building permit applications and construction plans must include the following information
that is applicable to the project:
• SETBACKS TO PROPERTY LINES: Provide a site plan, drawn to scale. Clearly identify all
structures, including fences, fuel tanks and other similar items, with setback dimensions on site
the plan.
• DISTANCES TO OTHER STRUCTURES: Site plan, drawn to scale shall clearly identify distances,
where required include fire-resistive details, including continuity, &tested assembly details.
• FIRE RESISTANCE FOR EXTERIOR WALLS: When applicable include fire-resistive details,
including continuity, &tested assembly details.
• IDENTIFY TYPE OF CONSTRUCTION & PROVIDE ALLOWABLE AREA CALCULATIONS WHERE
NEEDED. See Chapter 5, IBC. Type VB construction includes structures constructed with
combustible construction such as wood framed structures. Type II construction includes steel
structures constructed ENTIRELY by non-combustible construction.
• FIRE-RESISTIVE RATED CONSTRUCTION & TYPE OF CONSTRUCTION: Where required
demonstrate compliance. Identify the location of the assembly, compliance to continuity
requirements and construction details:
EXTERIOR WALL(IBC704), FIRE WALL(IBC705), FIRE BARRIER(IBC706), SHAFT ENCLOSURES
(IBC 707), FIRE PARTITIONS(IBC 708), SMOKE BARRIERS(IBC 709), SMOKE PARTITIONS(IBC
710), HORIZONTAL ASSEMBLIES (IBC 711), PENETRATIONS(IBC 712), FIRE-RESISTANT JOINT
SYSTEMS(IBC 713), FIRE-RESISTANCE RATING OF STRUCTUURAL MEMBERS(IBC 714),
OPENING PROTECTION (IBC 715), DUCT&AIR TRANSFER OPENINGS(IBC 716), CONCEALED
SPACES(IBC 717), ETC,
• NUMBER OF EXITS REQUIRED/OCCUPANT LOAD:(IBC 1004): Table 1004 is used to determine
occupant load used to evaluate the structure for exiting purposes, plumbing fixture requirements,
and other code related concerns. Include design calculations, demonstrating how occupant loads
were calculated, on building plans.
• EXIT PLAN: Clearly identify the exit path and exit signage on construction plans.
• ENGINEERING REQUIRED: Structures that do not comply with prescriptive specifications of the
2012 International Code (IBC) shall be designed in accordance with Chapter 16 of the IBC.
Referencing Washington State RCW 18.08.410 - Structures 4000 sq. ft or more shall have all plan
pages reviewed and stamped by a Washington State licensed design professional. The review
shall include a code evaluation addressing life-safety, plumbing & mechanical evaluation, and
structural analysis. (ref. RCW 18.08.410) ALL PLAN PAGES SHALL BE STAMPED AND SIGNED
BY THE DESIGN PROFESSIONAL, including plumbing and mechanical pages.
• ACCESSIBILITY REQUIRED: YES, include compliance information including design calculations
demonstrating compliance to Chapter 11 and details demonstrating compliance to ANSI 117.1 in
effect at the time of submittal. Include information demonstrating compliance for restrooms,
employee work areas, parking spaces, accessibility to structure, drinking fountain, signage, etc.
When required verify that building plans contain compliance information.
• PLUMBING SYSTEMS (Chapter 29 Washington Amendment to IBC): Using IBC Chapter 10, determine
occupant load. The number of plumbing fixtures is determined based upon the occupant load.
Plumbing fixtures need not be provided for unoccupied buildings. Permitted building shall
comply. On plans, include design calculations for the following: water closets (M/F), Lavatories,
Drinking Fountains, etc.
Referencing IBC/WAC 2902.2 separate plumbing fixtures shall be required for each sex, except
when the calculated occupancy load is 15 or less, and then unisex fixtures shall be allowed.
Plumbing fixture count can be for the entire facility, including all structures)for compliance
purposes. Provide design calculations demonstrating how the fixture count was determined on
construction plans.
• NON-RESIDENTIAL ENERGY CODE: ALL enclosed spaces require Non-Residential Energy
Conservation Code (IECC/WSEC). Provide completed compliance forms (envelope & mechanical).
Forms are available at:
Envelope: http://neec.net/sites/default/files/neec codes/forms12/env12V-v3.xlsm
Mechanical: http://neec.net/sites/default/files/neec codes/formsl2/MECH12-v3a.xlsm
• LIGHTING: All non-residential structures shall comply with IECC/WSEC lighting requirements.
Complete compliance forms and provide a lighting plan that includes switching locations. WSEC
forms and information can be accessed at:
Lighting: http://neec.net/sites/default/files/neec codes/formsl2/LTG12-v3c.xlsm
• Ventilation and Indoor Air Quality Code compliance: Provide calculations.
• COMMERCIAL KITCHEN: Show compliance to Chapter 5 of the International Mechanical Code
when a kitchen is included in the project.
• GEOTECH REPORT REQUIRED? YES X / NO
• OIL SEPARATOR: REQUIRED when vehicle repair work is performed. Identify location and
provide construction details.
PROVIDE a SPACE FOR STORAGE OF RECYCLED MATERIAL & SOLID WASTE (WAC51-50-009):
Identify the location.
• SPECIAL INSPECTION: Referencing IBC Chapter 17, Section 1704.1.1. Statement of special
inspections prepared by registered design professional in responsible charge. Complete a Special
Inspection authorization form.
• INTERIOR FINISHES: Include information demonstrating compliance to Interior finishes required in
IBC Chapter 8.
• STORAGE SPACES: Identify material stored, anticipated quantities, height, and if hazardous,
include MSDS sheets for each product.
• STORAGE RACKS: greater than 5'9" shall be permitted either with the proposed project or separate
building permit. Where required documents shall include design information demonstrating
stability for seismic conditions. Special inspection may be necessary, reference IBC Section
1707.6 and 1705.3 (4.5), storage racks, provide compliance information.
• MECHANICAL EQUIPMENT: Identify the location and type of mechanical equipment located within,
and outside the structure. Address foundation and support systems for equipment. Where new
equipment will be placed on site provide UL listing information and/or construction details
stamped by a Washington State licensed design professional. Where applicable include duct
information and duct support compliance information.
• FIRE MARSHAL REQUIREMENTS: Carefully review Fire Marshal comments requirements including
fire protection requirements and identify compliance information on the proposed building plans.
Show the location of fire extinguishers and identify type.
The Fire Marshal Review is pending, he is out for two weeks and we have not received his
comments.
• SPRINKLER SYSTEM: Verify that design calculations include additional load attributed to required
fire sprinkler system.
• SUSPENDED CEILING SYSTEMS: Provide details and specifications relating to suspended
ceilings where applicable. Details shall be designed and approved for seismic loading in
accordance to IBC Chapter 16. Where required designate special inspection plan.
• STORMWATER MANAGEMENT: A Plan must be submitted in accordance with Mason County Code
Title 14.48.Stormwater Management plan must meet WA State Department of Ecology's 2005
Stormwater Regulations.
PERMITS REQUIRED FOR PROJECT:
o BUILDING (each structure)
o PLUMBING / MECHANICAL (each structure)
o GRADING PERMIT (When greater than 200 cubic yards)
o CHANGE OF USE/OCCUPANCY (When each Tenant is identified for use)
o FIRE SUPPRESSION, See Fire Marshal comments (each structure)
o SIGN (each business)
o FENCE (Greater than 7'0" above grade)
o RETAINING WALL(S) (one permit for all walls on parcel)
ADDITIONAL NOTES:
WHEN YOU ARE READY, SUBMIT FOUR (4 SITE PLANS, DRAWN TO SCALE ALONG WITH THREE (3)
COMPLETE SETS OF BUILDING PLANS INCLUDING THE FOLLOWING. (NOTE: ALL PLAN PAGES SHALL
BE STAMPED BY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHEN THE STRUCTURE
EXCEEDS 4000 SQ. FT.):
• CONSTRUCTION PLANS, drawn to scale. Include floor plan, elevations, cross section, cross section,
construction details, etc.
• MECHANICAL PLAN,
• PLUMBING PLAN AND
• NON-RESIDENTIAL ENERGY CODENENTILATION & INDOOR AIR QUALITY CODE INFORMATION.
• DEFERRED SUBMITTAL WILL NOT BE ACCEPTED.
• A PLAN REVIEW FEE WILL BE COLLECTED WHEN THE BUILDING PERMIT IS SUBMITTED.
VALUATIONS ARE BASED UPON THE MOST RECENT BUILDING STANDARDS VALUATION DATA
RECOMMENDATIONS AND THE PERMIT FEE WILL BE DETERMINED BASED UPON TABLE 1-A OF
THE 1997 UBC.
DESIGN CRITERIA:
SEISMIC ZONE: D2
WIND SPEED: 85 MPH basic 110 ultimate, Exp B (Unless proven otherwise)
GROUND SNOW LOAD: 25 PSF
REFERENCE CODE EDITIONS: Effective July 1, 2013
2012 INTERNATIONAL BUILDING CODE(IBC), INCLUDING APPENDIX CHAPTERS C, E AND H, EXCLUDING
H106; SECTIONS 101 THROUGH 107, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL,AND EXCLUDING
APPENDIX CHAPTERS A, B, D, F, G, I, J AND K AND;ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-
50,AND THE 2012 INTERNATIONAL EXISTING BUILDING CODE.
2012 UNIFORM PLUMBING CODE(UPC), PUBLISHED BY THE INTERNATIONAL ASSN. OF PLUMBING AND
MECHANICAL OFFICIALS(IAPMO)AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-56 AND WAC
51-57, EXCLUDING SECTIONS 102.4 AND CHAPTERS 12, 15, AND 16, PART I.
2012 INTERNATIONAL MECHANICAL CODE(IMC), PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, AND
THE 2009 INTERNATIONAL FUEL GAS CODE AS ADOPTED THROUGH THE WASHINGTON STATE BUILDING CODE WAC
51-52.
2012 INTERNATIONAL FIRE CODE, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, EXCLUDING APPENDIX A, D,
AND KAND ADOPTING APPENDICES B,C,E,F, G AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-
54.
2012 INTERNATIONAL ENERGY CONSERVATION CODE(IECC),AS AMENDED BY WASHINGTON STATE BUILDING
CODE WAC 51-11
To view the Mason County Building and Construction Code and adopted amendments go to the
Mason County website at: www.co.mason.wa.us.
ATTENTION: THE ABOVE LISTED CODES ARE TO BE UPDATED TO THE
2015 CODES JULY 1, 2016
you
MASON COUNTY ? q (360) 427-9670 Shelton ext.352
oK
DEPARTMENT OF COMMUNITY DEVELOPMENT (360) 275-4467 Belfair ext. 352
BUILDING• PLANNING• FIRE MARSHAL (360)482-5269 Elma ext. 352
—_ Mason County Bldg 8, 615 West Alder Street
Shelton, WA 98584 www.co.masonma.us
IN51
RE: Pre-Submission Conference
PAR2016-00026
Parcel Number: 42002-44-00010
Dear Applicant,
Please find enclosed a computer-generated report summarizing the results of your pre-submission
conference on 6/1/2016 if you have questions regarding the summary report,please do not hesitate to call
the appropriate staff member.
The various staff members, the departments they represent and their telephone extensions are listed
below:
DEPARTMENT STAFF MEMBER EXTENTSION INITIALS
Fire Inspector/Comm. Dev. Jeromy Hicks 282 JNH
Building/Comm. Dev. Trish Woolett 281 TW
Environ. Health Spec./Public Health Alex Pa sse 279 ALP
Eng. Tech/Public Works Fred Perryman 625 FJP
Planner/Comm. Dev. Grace Miller 360 GBM
Planner/Comm. Dev. Rebecca Hersha 287 RDH
Planner/Comm. Dev. Kell McAboy 365 KJM
Planner/Comm. Dev Michael MacSems 571 MMS
Stormwater Eng./Public Works Loretta Swanson 769 LGS
The comments are based on the project discussed during the pre-submission conference. Any changes or
alterations to the original proposal may significantly change the permit requirements. In this case a
second pre-submission conference will most likely be required to discuss the changes.
Information provided to the prospective applicant during the pre-submission conference is based on
Mason County regulations in effect at the time of the conference. Revised or new regulations could affect
a future development application. A pre-submission conference does not vest a future development
application.
If further assistance is needed please contact us at 360.427.9670 ext. 352 or www.co.mason.wa.us.
Case Activity Listing 7/29/2016
3:09:24PM
Case #: PAR2016-00026
Parcel #: 420024400010
Description: PRE APPLICATION REVIEW FOR PROPOSED FARM & FEED STORE WITH ASSOCIATED RETAIL AREA,STORAGE &
OFFICE SPACE. MAIN BLDG FOOTPRINT: 21,930, SEPARATE DETACHED HAY BARN FOOTPRINT: 2000
PARA 10 Application Received 5/24/2016 None GMM 5/24/2016 GMM
PARB60 Fire Marshal Review 5/24/2016 None 5/24/2016 GMM
PARB40 Environ. Health Review 5/24/2016 6/1/2016 None DONE ALP 6/1/2016 ALP
Sewer: City of Shelton has confirmed connection the sewer system is available and within300ft. Being in the Critical Aquifer Recharge Area connection the sewer is required. A signed sewer adequacy form
is required for review of any building permits involving plumbing
Water: City of Shelton has confirmed connection to their water system is available for both drinking water and reclaim(irrigation)water. A signed water adequacy form is required for review of any building
permits with water facilities.
Page 1 of 6 CaseActivity..rpt
Case Activity Listing 7/29/2016
3:09:24PM
Case #: PAR2016-00026
t Parcel #: 420024400010
Description: PRE APPLICATION REVIEW FOR PROPOSED FARM & FEED STORE WITH ASSOCIATED RETAIL AREA,STORAGE &
OFFICE SPACE. MAIN BLDG FOOTPRINT: 21,930, SEPARATE DETACHED HAY BARN FOOTPRINT: 2000
PARB20 Building Plan Review 5/24/2016 6/l/2016 None DONE TW 6/2/2016 TW
BUILDING DEPARTMENT REPRESENTATIVE: (360)427-9670 ext.281
E-Mail:tw@co.mason.waus
" DATE: June 1 st,2016
PROJECT/PROJECT TRACKING NUMBER:PAR2016-00026
PROJECT REPRESENTATIVE(S): Tractor Supply Company-Pedro DeGuzman,PE
DESCRIPTION&SIZE OF PROJECT/OCCUPANCY CLASSIFICATION&USE: Proposed Farm&Feed Store with associated retail area,storage&office space,main building footage=21,930,separate
detached Hay Barn—2,000 sq ft Occupancy=M,Construction Type=IIB,proposed outdoor storage&display areas,parking and landscaping.2 existing mini-storage bldgs,drives,grass areas to be cleared.
ATTENTION:BUILDING CODES ARE TO BE UPDATED TO
THE 2015 CODES JULY 1,2016
Complete building permit applications and construction plans must include the following information that is applicable to the project
H
SETBACKS TO PROPERTY LINES. Provide a site plan,drawn to scale.Clearly identify all structures,including fences,fuel tanks and other similar items,with setback dimensions on site the plan.
it DISTANCES TO OTHER STRUCTURES: Site plan,drawn to scale shall clearly identify distances,where required include fire-resistive details,including continuity,&tested assembly details.
it FIRE RESISTANCE FOR EXTERIOR WALLS: When applicable include fire-resistive details,including continuity,&tested assembly details.
it IDENTIFY TYPE OF CONSTRUCTION&PROVIDE ALLOWABLE AREA CALCULATIONS WHERE NEEDED. See Chapter 5,IBC. Type VB construction includes structures constructed with
combustible construction such as wood framed structures. Type 11 construction includes steel structures constructed ENTIRELY by non-combustible construction.
It
FIRE-RESISTIVE RATED CONSTRUCTION&TYPE OF CONSTRUCTION: Where required demonstrate compliance. Identify the location of the assembly,compliance to continuity requirements
and construction details:
EXTERIOR WALL(IBC704),FIRE WALL(IBC705),FIRE BARRIER(IBC706),SHAFT ENCLOSURES(IBC 707),FIRE PARTITIONS(IBC 708),SMOKE BARRIERS(IBC 709),SMOKE
PARTITIONS(IBC 710),HORIZONTAL ASSEMBLIES(IBC 711),PENETRATIONS(IBC 712),FIRE-RESISTANT JOINT SYSTEMS(IBC 713),FIRE-RESISTANCE RATING OF STRUCTUURAL
MEMBERS(IBC 714),OPENING PROTECTION(IBC 715),DUCT&AIR TRANSFER OPENINGS(IBC 716), CONCEALED SPACES(IBC 717),ETC,
ff NUMBER OF EXITS REQUIRED/OCCUPANT LOAD:(IBC 1004):Table 1004 is used to determine occupant load used to evaluate the structure for exiting purposes,plumbing fixture requirements,
and other code related concerns. Include design calculations,demonstrating how occupant loads were calculated,on building plans.
" EXIT PLAN: Clearly identify the exit path and exit signage on construction plans
of ENGINEERING REQUIRED:Structures that do not comply with prescriptive specifications of the 2012 International Code(IBC)shall be designed in accordance with Chapter 16 of the IBC.
Referencing Washington State RCW 18.08.410-Structures 4000 sq.ft or more shall have all plan pages reviewed and stamped by a Washington State licensed design professional. The review shall include a
code evaluation addressing life-safety,plumbing&mechanical evaluation,and structural analysis.(ref.RCW 18.08.410) ALL PLAN PAGES SHALL BE STAMPED AND SIGNED BY THE DESIGN
Page 2 of 6 CaseActivity-rpt
I6
Case Activity Listing 3:7/29/29/202016
Case #: PAR2016-00026
Parcel #: 420024400010
Description: PRE APPLICATION REVIEW FOR PROPOSED FARM & FEED STORE WITH ASSOCIATED RETAIL AREA,STORAGE &
OFFICE SPACE. MAIN BLDG FOOTPRINT: 21,930, SEPARATE DETACHED HAY BARN FOOTPRINT: 2000
—"a t Me- ato -;A I r
PROFESSIONAL,including plumbing and mechanical pages
It
ACCESSIBILITY REQUIRED: YES,include compliance information including design calculations demonstrating compliance to Chapter 11 and details demonstrating compliance to ANSI 117.1 in
effect at the time of submittal.Include information demonstrating compliance for restrooms,employee work areas,parking spaces,accessibility to structure,drinking fountain,signage,etc. When required
verify that building plans contain compliance information
It
PLUMBING SYSTEMS(Chapter 29 Washington Amendment to IBC): Using IBC Chapter 10,determine occupant load. The number of plumbing fixtures is determined based upon the occupant load
Plumbing fixtures need not be provided for unoccupied buildings Permitted building shall comply. On plans,include design calculations for the following: water closets(M/F),Lavatories,Drinking
Fountains,etc.
Referencing IBC/WAC 2902.2 separate plumbing fixtures shall be required for each sex,except when the calculated occupancy load is 15 or less,and then unisex fixtures shall be allowed
Plumbing fixture count can be for the entire facility,including all structures)for compliance purposes. Provide design calculations demonstrating how the fixture count was determined on construction plans
to NON-RESIDENTIAL ENERGY CODE:ALL enclosed spaces require Non-Residential Energy Conservation Code(IECC/WSEC). Provide completed compliance forms(envelope&mechanical).
Forms are available at:
Enveloper http://neec.net/sites/default/files/neec_codes/forms l2/env l2V-v3.xlsm
Mechanical:http://neec.net/sites/default/filestneec_codes/formsl2/MECH12-v3a.xism
LIGHTING:All non-residential structures shall comply with IECC/WSEC lighting requirements Complete compliance forms and provide a lighting plan that includes switching locations WSEC forms
and information can be accessed at:
Lighting:http://neec.net/sites/default/files/neec_codes/formsl2/LTG12-v3c.xism
Ventilation and Indoor Air Quality Code compliance:Provide calculations.
COMMERCIAL KITCHEN: Show compliance to Chapter 5 of the International Mechanical Code when a kitchen is included in the project.
GEOTECH REPORT REQUIRED? YES_X_/NO
OIL SEPARATOR: REQUIRED when vehicle repair work is performed Identify location and provide construction details
" PROVIDE a SPACE FOR STORAGE OF RECYCLED MATERIAL&SOLID WASTE(WAC51-50-009):Identify the location.
SPECIAL INSPECTION:Referencing IBC Chapter 17,Section 1704.1.1. Statement of special inspections prepared by registered design professional in responsible charge. Complete a Special
Inspection authorization form.
to
INTERIOR FINISHES:Include information demonstrating compliance to Interior finishes required in IBC Chapter 8.
STORAGE SPACES: Identify material stored,anticipated quantities,height,and if hazardous,include MSDS sheets for each product.
Page 3 of 6 CaseActivity.spot
Case Activity Listing 7/29/2016
3:09:24PM
lip, Case #: PAR2016-00026
Parcel #: 420024400010
Description: PRE APPLICATION REVIEW FOR PROPOSED FARM & FEED STORE WITH ASSOCIATED RETAIL AREA,STORAGE &
OFFICE SPACE. MAIN BLDG FOOTPRINT: 21,930, SEPARATE DETACHED HAY BARN FOOTPRINT: 2000
ctu'' a ►::i ti r,, . to 1• .
STORAGE RACKS:greater than 5'9"shall be permitted either with the proposed project or separate building permit Where required documents shall include design information demonstrating stability
for seismic conditions. Special inspection may be necessary,reference IBC Section 1707.6 and 1705.3(4.5),storage racks,provide compliance information.
" MECHANICAL EQUIPMENT: identify the location and type of mechanical equipment located within,and outside the structure. Address foundation and support systems for equipment Where new
equipment will be placed on site provide UL listing information and/or construction details stamped by a Washington State licensed design professional. Where applicable include duct information and duct
support compliance information.
11 FIRE MARSHAL REQUIREMENTS: Carefully review Fire Marshal comments requirements including fire protection requirements and identify compliance information on the proposed building plans
Show the location of fire extinguishers and identify type
The Fire Marshal Review is pending,he is out for two weeks and we have not received his comments
SPRINKLER SYSTEM: Verify that design calculations include additional load attributed to required fire sprinkler system
SUSPENDED CEILING SYSTEMS: Provide details and specifications relating to suspended ceilings where applicable. Details shall be designed and approved for seismic loading in accordance to IBC
Chapter 16. Where required designate special inspection plan.
" STORM WATER MANAGEMENT.A Plan must be submitted in accordance with Mason County Code Title 14.48.Stormwater Management plan must meet WA State Department of Ecology's 2005
Stormwater Regulations.
PERMITS REQUIRED FOR PROJECT:
BUILDING(each structure)
PLUMBING/MECHANICAL(each structure)
GRADING PERMIT(When greater than 200 cubic yards)
CHANGE OF USE/OCCUPANCY(When each Tenant is identified for use)
FIRE SUPPRESSION,See Fire Marshal comments(each structure)
SIGN(each business)
FENCE(Greater than TO"above grade)
RETAINING WALL(S)(one permit for all walls on parcel)
ADDITIONAL NOTES:
WHEN YOU ARE READY,SUBMIT FOUR(4 SITE PLANS,DRAWN TO SCALE ALONG WITH THREE(3)COMPLETE SETS OF BUILDING PLANS INCLUDING THE FOLLOWING. (NOTE:
ALL PLAN PAGES SHALL BE STAMPED BY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHEN THE STRUCTURE EXCEEDS 4000 SQ.FT.):
CONSTRUCTION PLANS,drawn to scale.Include floor plan,elevations,cross section,cross section,construction details,etc.
MECHANICAL PLAN,
PLUMBING PLAN AND
NON-RESIDENTIAL ENERGY CODE/VENTILATION&INDOOR AIR QUALITY CODE INFORMATION.
DEFERRED SUBMITTAL WILL NOT BE ACCEPTED.
" A PLAN REVIEW FEE WILL BE COLLECTED WHEN THE BUILDING PERMIT IS SUBMITTED.VALUATIONS ARE BASED UPON THE MOST RECENT BUILDING STANDARDS
VALUATION DATA RECOMMENDATIONS AND THE PERMIT FEE WILL BE DETERMINED BASED UPON TABLE 1-A OF THE 1997 UBC.
Page 4 of 6 Casenctivity..rpi
Case Activity Listing 7/29/2016
3:09:24PM
lip, Case #: PAR2016-00026
Parcel #: 420024400010
Description: PRE APPLICATION REVIEW FOR PROPOSED FARM & FEED STORE WITH ASSOCIATED RETAIL AREA,STORAGE &
OFFICE SPACE. MAIN BLDG FOOTPRINT: 21,930, SEPARATE DETACHED HAY BARN FOOTPRINT: 2000
e K' tia Ert.printed By
DESIGN CRITERIA:
SEISMIC ZONE: D2
WIND SPEED: 85 MPH basic 110 ultimate,Exp B (Unless proven otherwise)
GROUND SNOW LOAD: 25 PSF
REFERENCE CODE EDITIONS: Effective July 1,2013
2012 INTERNATIONAL BUILDING CODE(IBC), INCLUDING APPENDIX CHAPTERS C,E AND H,EXCLUDING H 106;SECTIONS 101 THROUGH 107, PUBLISHED BY THE
INTERNATIONAL CODE COUNCIL,AND EXCLUDING APPENDIX CHAPTERS A,B,D,F,G,I,J AND K AND;ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-50,AND
THE 2012 INTERNATIONAL EXISTING BUILDING CODE.
2012 UNIFORM PLUMBING CODE(UPC), PUBLISHED BY THE INTERNATIONAL ASSN.OF PLUMBING AND MECHANICAL OFFICIALS(IAPMO)AND ADOPTING THE WASHINGTON
STATE BUILDING CODE WAC 51-56 AND WAC 51-57,EXCLUDING SECTIONS 102.4 AND CHAPTERS 12, 15,AND 16,PART I.
2012 INTERNATIONAL MECHANICAL CODE(IMC),PUBLISHED BY THE INTERNATIONAL CODE COUNCIL,AND THE 2009 INTERNATIONAL FUEL GAS CODE AS ADOPTED THROUGH
THE WASHINGTON STATE BUILDING CODE WAC 51-52.
2012 INTERNATIONAL FIRE CODE,PUBLISHED BY THE INTERNATIONAL CODE COUNCIL,EXCLUDING APPENDIX A,D,AND K AND ADOPTING APPENDICES B,C,E,F,G AND
ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-54.
2012 INTERNATIONAL ENERGY CONSERVATION CODE(IECC),AS AMENDED BY WASHINGTON STATE BUILDING CODE WAC 5 1-11
To view the Mason County Building and Construction Code and adopted amendments go to the Mason County website at www.co.mason.waus.
ATTENTION:THE ABOVE LISTED CODES ARE TO BE UPDATED TO THE 2015 CODES JULY 1,2016
PARB50 Public Works Review 5/24/2016 6/1/2016 None DONE FJP 6/2/2016 TW
Access is from a State Highway so all access issues and approvals and approvals need to be addressed by Washington State Department of Transportation
Page 5 of 6 CaseActivity-rpt
Case Activity Listing 7/29/2016
3:09:24PM
Case #: PAR2016-00026
Parcel #: 420024400010
Description: PRE APPLICATION REVIEW FOR PROPOSED FARM & FEED STORE WITH ASSOCIATED RETAIL AREA,STORAGE &
OFFICE SPACE. MAIN BLDG FOOTPRINT: 21,930, SEPARATE DETACHED HAY BARN FOOTPRINT: 2000
al
v .Aesc i t` e
PARB10 Planning Review 5/24/2016 7/27/2016 None DONE GBM GBM 7/28/2016 GBM
Grace Miller attended the meeting on behalf of the Planning Department The property is located within the Shelton Urban Growth Area and is Zoned as General Commercial,Zoning Chapter 17.07.300 was
given to applicants at the meeting.Retail stores are a permitted use under 17.07.320(18).
Setbacks-No setbacks are listed within this zoning but must meet the Landscaping Section 17.07.860(A)(1)perimeter areas,(B)Buffer areas,etc.which requires plantings along perimeters of development,
etc.The Building Code requirements apply and WSDOT requirements for commercial access and setbacks also apply.
Maximum Height-Maximum height is not to exceed 45'for buildings,structures,and appurtenant facilities.
Parking-The Parking Requirements are listed within Chapter 17.08 that staff gave to applicant at the meeting.
Landscaping-The Landscaping requirements are listed within Chapter 17.07.800.
MC Resource Ordinance Critical Aquifer Recharge Area- The property is regulated by the Mason County Resource Ordinance as a Critical Aquifer Recharge Area,Class II-Highly Susceptible.The
development must comply with this chapter with the impervious surfaces and stormwater designed so that it will not impact the critical aquifer rechage area.A Title Notification will need to be recorded with
the deed as required by the Aquifer chapter.Staff gave applicant the requirements at meeting
MC Resource Ordinance FWHCA-On June 8,2016 staff inspected the property and did not observe any evidence of pocket gopher use Therefore,a pocket gopher study will not be required as had been
indicated as a possibility during the pre-application meeting.The pocket gopher habitat is regulated by the Mason County Resource Ordinance Fish and Wildlife Habitat Conservation Area Chapter.
Airport Overlay-The property is designated as a Zone 6,Traffic Pattern Zone,within the MC Airport Overlay Zone Ordinance.Staff gave the applicants a copy of this ordinance at the meeting
Signs-As long as the proposed sign meets the MC Sign Ordinance requirements,it may be permitted through the Bulding Permit process There does not appear to be any specific size allowances/retriction
for the General Commercial Zoning within the Urban Growth Area.The existing billboard can remain and advertise on site use but cannot advertise off premise uses.
SEPA will be required because there are over 20 parking spaces and the size of the buildings exceed 20,000 square feet.You may complete an Evironmental Checklist and submit it with the Building Permit
Application.
If you have not already,pPlease contact Bob Tauscher,Civil Engineer with the City of Shelton,for questions regarding the Watermain along Hwy 101.Bob came to the meeting and said that the city
watermain is not operating yet but will be soon.
Page 6 of 6 CaseActivity..rpt
��So� °fltr rp
MASON COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
Building Division
- Mason County Bldg. 8, 615 West Alder Street, Shelton, WA 98584
185J www.co.masonma.us (360)427-9670 Belfair(360)275-4467 Elma(360)482-5269
MASON COUNTY PRE-SUBMISSION CONFERENCE NOTES
• BUILDING DEPARTMENT REPRESENTATIVE: (360) 427-9670 ext. 281
E-Mail: tw@co.mason.wa.us
• DATE: June 1st, 2016
• PROJECT/ PROJECT TRACKING NUMBER: PAR2016-00026
• PROJECT REPRESENTATIVE (S): Tractor Supply Company- Pedro DeGuzman, PE
DESCRIPTION & SIZE OF PROJECT/OCCUPANCY CLASSIFICATION & USE: Proposed Farm & Feed Store
with associated retail area, storage & office space, main building footage= 21,930, separate detached Hay
Barn= 2,000 sq ft, Occupancy-- M, Construction Type= IIB, proposed outdoor storage & display areas,
parking and landscaping. 2 existing mini-storage bldgs, drives, grass areas to be cleared.
ATTENTION: BUILDING CODES ARE TO BE UPDATED TO
THE 2015 CODES JULY 1, 2016
Complete building permit applications and construction plans must include the following information
that is applicable to the project:
• SETBACKS TO PROPERTY LINES: Provide a site plan, drawn to scale. Clearly identify all
structures, including fences, fuel tanks and other similar items, with setback dimensions on site
the plan.
• DISTANCES TO OTHER STRUCTURES: Site plan, drawn to scale shall clearly identify distances,
where required include fire-resistive details, including continuity, &tested assembly details.
• FIRE RESISTANCE FOR EXTERIOR WALLS: When applicable include fire-resistive details,
including continuity, &tested assembly details.
• IDENTIFY TYPE OF CONSTRUCTION & PROVIDE ALLOWABLE AREA CALCULATIONS WHERE
NEEDED. See Chapter 5, IBC. Type VB construction includes structures constructed with
combustible construction such as wood framed structures. Type II construction includes steel
structures constructed ENTIRELY by non-combustible construction.
• FIRE-RESISTIVE RATED CONSTRUCTION &TYPE OF CONSTRUCTION: Where required
demonstrate compliance. Identify the location of the assembly, compliance to continuity
requirements and construction details:
EXTERIOR WALL(IBC704), FIRE WALL(IBC705), FIRE BARRIER(IBC706), SHAFT ENCLOSURES
(IBC 707), FIRE PARTITIONS(IBC 708), SMOKE BARRIERS(IBC 709), SMOKE PARTITIONS(IBC
710), HORIZONTAL ASSEMBLIES(IBC 711), PENETRATIONS(IBC 712), FIRE-RESISTANT JOINT
SYSTEMS(IBC 713), FIRE-RESISTANCE RATING OF STRUCTUURAL MEMBERS(IBC 714),
OPENING PROTECTION (IBC 715), DUCT&AIR TRANSFER OPENINGS(IBC 716), CONCEALED
SPACES(IBC 717), ETC,
• NUMBER OF EXITS REQUIRED/OCCUPANT LOAD:(IBC 1004): Table 1004 is used to determine
occupant load used to evaluate the structure for exiting purposes, plumbing fixture requirements,
and other code related concerns. Include design calculations, demonstrating how occupant loads
were calculated, on building plans.
• EXIT PLAN: Clearly identify the exit path and exit signage on construction plans.
• ENGINEERING REQUIRED: Structures that do not comply with prescriptive specifications of the
2012 International Code (IBC) shall be designed in accordance with Chapter 16 of the IBC.
Referencing Washington State RCW 18.08.410 - Structures 4000 sq. ft or more shall have all plan
pages reviewed and stamped by a Washington State licensed design professional. The review
shall include a code evaluation addressing life-safety, plumbing & mechanical evaluation, and
structural analysis. (ref. RCW 18.08.410) ALL PLAN PAGES SHALL BE STAMPED AND SIGNED
BY THE DESIGN PROFESSIONAL, including plumbing and mechanical pages.
• ACCESSIBILITY REQUIRED: YES, include compliance information including design calculations
demonstrating compliance to Chapter 11 and details demonstrating compliance to ANSI 117.1 in
effect at the time of submittal. Include information demonstrating compliance for restrooms,
employee work areas, parking spaces, accessibility to structure, drinking fountain, signage, etc.
When required verify that building plans contain compliance information.
• PLUMBING SYSTEMS (Chapter 29 Washington Amendment to IBC): Using IBC Chapter 10, determine
occupant load. The number of plumbing fixtures is determined based upon the occupant load.
Plumbing fixtures need not be provided for unoccupied buildings. Permitted building shall
comply. On plans, include design calculations for the following: water closets (M/F), Lavatories,
Drinking Fountains, etc.
Referencing IBC/WAC 2902.2 separate plumbing fixtures shall be required for each sex, except
when the calculated occupancy load is 15 or less, and then unisex fixtures shall be allowed.
Plumbing fixture count can be for the entire facility, including all structures) for compliance
purposes. Provide design calculations demonstrating how the fixture count was determined on
construction plans.
• NON-RESIDENTIAL ENERGY CODE: ALL enclosed spaces require Non-Residential Energy
Conservation Code (IECC/WSEC). Provide completed compliance forms (envelope & mechanical).
Forms are available at:
Envelope: http://neec.net/sites/default/files/neec codes/forms12/env12V-v3.xlsm
Mechanical: http://neec.net/sites/default/files/neec codes/forms12/MECH12-v3a.xlsm
• LIGHTING: All non-residential structures shall comply with IECC/WSEC lighting requirements.
Complete compliance forms and provide a lighting plan that includes switching locations. WSEC
forms and information can be accessed at:
Lighting: http://neec.net/sites/default/files/neec codes/forms12/LTG12-v3c.xlsm
• Ventilation and Indoor Air Quality Code compliance: Provide calculations.
• COMMERCIAL KITCHEN: Show compliance to Chapter 5 of the International Mechanical Code
when a kitchen is included in the project.
• GEOTECH REPORT REQUIRED? YES X / NO
• OIL SEPARATOR: REQUIRED when vehicle repair work is performed. Identify location and
provide construction details.
r
• PROVIDE a SPACE FOR STORAGE OF RECYCLED MATERIAL & SOLID WASTE (WAC51-50-009):
Identify the location.
• SPECIAL INSPECTION: Referencing IBC Chapter 17, Section 1704.1.1. Statement of special
inspections prepared by registered design professional in responsible charge. Complete a Special
Inspection authorization form.
• INTERIOR FINISHES: Include information demonstrating compliance to Interior finishes required in
IBC Chapter 8.
• STORAGE SPACES: Identify material stored, anticipated quantities, height, and if hazardous,
include MSDS sheets for each product.
• STORAGE RACKS: greater than 59" shall be permitted either with the proposed project or separate
building permit. Where required documents shall include design information demonstrating
stability for seismic conditions. Special inspection may be necessary, reference IBC Section
1707.6 and 1705.3 (4.5), storage racks, provide compliance information.
• MECHANICAL EQUIPMENT: Identify the location and type of mechanical equipment located within,
and outside the structure. Address foundation and support systems for equipment. Where new
equipment will be placed on site provide UL listing information and/or construction details
stamped by a Washington State licensed design professional. Where applicable include duct
information and duct support compliance information.
• FIRE MARSHAL REQUIREMENTS: Carefully review Fire Marshal comments requirements including
fire protection requirements and identify compliance information on the proposed building plans.
Show the location of fire extinguishers and identify type.
The Fire Marshal Review is pending, he is out for two weeks and we have not received his
comments.
• SPRINKLER SYSTEM: Verify that design calculations include additional load attributed to required
fire sprinkler system.
• SUSPENDED CEILING SYSTEMS: Provide details and specifications relating to suspended
ceilings where applicable. Details shall be designed and approved for seismic loading in
accordance to IBC Chapter 16. Where required designate special inspection plan.
• STORMWATER MANAGEMENT: A Plan must be submitted in accordance with Mason County Code
Title 14.48.Stormwater Management plan must meet WA State Department of Ecology's 2005
Stormwater Regulations.
PERMITS REQUIRED FOR PROJECT:
o BUILDING (each structure)
o PLUMBING / MECHANICAL (each structure)
o GRADING PERMIT (When greater than 200 cubic yards)
o CHANGE OF USE/OCCUPANCY (When each Tenant is identified for use)
o FIRE SUPPRESSION, See Fire Marshal comments (each structure)
o SIGN (each business)
o FENCE (Greater than 7'0" above grade)
o RETAINING WALL(S) (one permit for all walls on parcel)
ADDITIONAL NOTES:
WHEN YOU ARE READY, SUBMIT FOUR (4 SITE PLANS, DRAWN TO SCALE ALONG WITH THREE (3)
COMPLETE SETS OF BUILDING PLANS INCLUDINGTHE FOLLOWING. (NOTE:ALL PLAN PAGES SHALL
BE STAMPED BY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHEN THE STRUCTURE
EXCEEDS 4000 SQ. FT.):
• CONSTRUCTION PLANS, drawn to scale. Include floor plan, elevations, cross section, cross section,
construction details, etc.
• MECHANICAL PLAN,
• PLUMBING PLAN AND
• NON-RESIDENTIAL ENERGY CODE/VENTILATION & INDOOR AIR QUALITY CODE INFORMATION.
• DEFERRED SUBMITTAL WILL NOT BE ACCEPTED.
• A PLAN REVIEW FEE WILL BE COLLECTED WHEN THE BUILDING PERMIT IS SUBMITTED.
VALUATIONS ARE BASED UPON THE MOST RECENT BUILDING STANDARDS VALUATION DATA
RECOMMENDATIONS AND THE PERMIT FEE WILL BE DETERMINED BASED UPON TABLE 1-A OF
THE 1997 UBC.
DESIGN CRITERIA:
SEISMIC ZONE: D2
WIND SPEED: 85 MPH basic 110 ultimate, Exp B (Unless proven otherwise)
GROUND SNOW LOAD: 25 PSF
REFERENCE CODE EDITIONS: Effective July 1, 2013
2012 INTERNATIONAL BUILDING CODE(IBC), INCLUDING APPENDIX CHAPTERS C, E AND H, EXCLUDING
H106; SECTIONS 101 THROUGH 107, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL,AND EXCLUDING
APPENDIX CHAPTERS A, B, D, F, G, I, J AND K AND;ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-
50,AND THE 2012 INTERNATIONAL EXISTING BUILDING CODE.
2012 UNIFORM PLUMBING CODE(UPC), PUBLISHED BY THE INTERNATIONAL ASSN. OF PLUMBING AND
MECHANICAL OFFICIALS(IAPMO)AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-56 AND WAC
51-57, EXCLUDING SECTIONS 102.4 AND CHAPTERS 12, 15,AND 16, PART I.
2012 INTERNATIONAL MECHANICAL CODE(IMC), PUBLISHED BY THE INTERNATIONAL CODE COUNCIL,AND
THE 2009 INTERNATIONAL FUEL GAS CODE AS ADOPTED THROUGH THE WASHINGTON STATE BUILDING CODE WAC
51-52.
2012 INTERNATIONAL FIRE CODE, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, EXCLUDING APPENDIX A, D,
AND K AND ADOPTING APPENDICES B,GE,F, G AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-
54.
2012 INTERNATIONAL ENERGY CONSERVATION CODE(IECC),AS AMENDED BY WASHINGTON STATE BUILDING
CODE WAC 51-11
To view the Mason County Building and Construction Code and adopted amendments go to the
Mason County website at: www.co.mason.wa.us.
ATTENTION: THE ABOVE LISTED CODES ARE TO BE UPDATED TO THE
2015 CODES JULY 1, 2016