Loading...
HomeMy WebLinkAboutCOM2018-00132 Banquet Hall - COM Application - 11/14/2018 MASON COUNTY COMMUNITY SERVICES Permit No: re*00_1t%� PERMIT ASSISTANCE CENTER: BUILDING•PLANNING-PUBLIC HEALTH•FIRE MARSHAL R E C E 13 z I615 W. rget,6heltpn,WA 98564 Phone Shelton:(380)42 0 Cxt. ne•Fax:(360)42-5249 VEL Be/Iair.(380)27 •Phone Elma (380)482-52 N0V 14 201$ BUILDING PERMIT APPLICATION PROPERTY OWNER INFORMATION: CONTRACTOR IN T r treet NAME: Ridge Motor Sports NA : yKaufman Construction&Dev. Inc MAILING ADDRESS: PO BOX 2467 MAILING ADDRESS: 7711 Martin Way East CITY: Shelton STATE: WA .ZIP: 985M CITY: Olympia STATE: WA ZIP: 98516 PHONE#1: 1-206-900-5370 PHONE: CELL: 360-480-8197 PHONE#2: EMAIL: riley@kaufmancd.com EMAIL: traciedridgemp.com L&I REG# 548,338-01 EXP. 12 / 31/2018 PRIMARY CONTACT: OWNER❑ CONTRACTOR N OTHER❑ NAME Riley Wall EMAIL riley kaufmancd.com MAILING ADDRESS 7711 Marton Way East CITY Olympia STATE WA ZIP 98516 PHONE 360-491-5230 CELL 360-480-8197 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 42004-24-00000 ZONING Rural Commercial 3 LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT�� SITE ADDRESS 1060 W EELS HILL CITY Shelton DIRECTIONS TO SITE ADDRESS Head north on HWY 101,take a left on WA-102 W for 1.5 miles,Turn right onto W Eells Hill Rd for 0.9 Miles and turn right into the Ridge Motor Sports Park. IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Checkantlratapply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW N ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage.Commercial Bldg,Etc.) Commercial Banquet Hall IS USE: PRIMARY® SEASONAL❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS 4 HEATED STRUCTURE? YES OnweB/dg)® YES(Part/sjofBldg)❑ NO❑ DESCRIBE WORK SOUARE FOOTAGE:(propose+-isrrng) 1 ST FLOOR 4,400 sq.ft. 2ND FLOOR 4,400 sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC N SEWER❑ / NEW❑ EXISTING PLUMBING IN STRUCTURE? YES N NO❑ If yes,attach completed Water Adequacy Form PERIMETERNOUNDATION DRAINS PROPOSED? YES❑ NO❑ EXISTING SQ.FT. EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null 8 void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT LIGATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON Tv cooE 14.08.42)xIVACO Signature of OWNER(Must be sianed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITI CEI `/ ED BUILDING DEPARTMENT SRO PLANNING DEPARTMENT , 4 201° FIRE MARSHAL V v PUBLIC HEALTHAkJor t� MASON COUNTY COMMUNITY SERVICES PerrnitNor,,6m 2d PERMIT ASSISTANCE CENTER: j •BUILDING •PLANNING •FIRE MARSHAL 615 W. Alder St-Shelton WA 98584 RECEIVED www.co.mason.wa.us� h Phone Shelton:(360)427-967 ext." 52�' cIM 427-7798 NOV4 2��8 Phone Belfair.•(360)275-4467• Phone Elma:(360)482-5269 PLUMBING & MECHANICAL PERMIT APPLICfk�h&&der Street OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: RIDGE MOTORSPORTS NAME:AUBURN MECHANICAL MAILING ADDRESS:1060 W EELLS HILL MAILING ADDRESS:2623 WEST VALLEY HWY N CITY: SHELTON STATE:WA ZIP:98584 CITY: AUBURN STATE: WA ZIP: 98001 Is' PHONE: 360-427-7223 PHONE: 253-838-9780 CELL: 206-730-0068 2"d PHONE:206-900-5370 EMAIL : nickdayton auburnmechanical.com EMAIL:tracie@ridAemp.com L&I REG# AUBURM1163BA EXP. 09/12/2020 PARCEL INFORMATION: 42004-24-00000, 42004 10 eew, PARCEL NUMBER(12 Digit Number): Zoning: COMMERCIAL LEGAL DESCRIPTION (Abbreviated): SITE ADDRESS: 1060 W EELLS HILL CITY: SHELTON DIRECTIONS TO SITE ADDRESS: TYPE OF JOB: NEW X ADD ALT REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS— 1 ST FLOOR X 2ND FLOOR X BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric X LPG X Natural Gas Ductless_ Toilets N 7 Type of Unit No.of Units Fees Bathroom Sink Nt 5 Furnace `+ 4 Bath Tubs Heat Pump v 1 Showers Spot Vent Fan v 5 Water Heater 4 Propane Tank 1--A Clothes Washer Gas Outlets -S 'v Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher 1 Kitchen Exhaust Hoo ` 1 Hose bibs Z Dryer Vent Solar Panelys��y - 4 Other, '.N wls ks-"C1,1'�1 Base Fte V Y I'1.4 � baac ree 1 n� TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATIO OFTHIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALID THE APPLICATION. Signature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL „, .ev: i/ 7/201t JBni 1 VV too v_' Jdv�9'j 1�-t 0c) I*F VV C N -.p4jc)q vvA S - J S -z m 1��c1 APPROVED MASON COU NTY UCD PLANNING SCALE 1"-60 FEET v\ PLANNING SITE PLANREQUI7RED TO BE ON SITE D so fio ,zo � /'`�r1�N k .'� \ CHANGES SUBJECT TO APPROVAL .ARE M-EPrSCI / eY--- /.tu .emu D to _ Y: - - _ _ ■ ALL SET S l \ ■ F MT = == -- OF THE BUILDING -' ' PRO C`T N -� _=__ " _ -'-= ■ 5C — - - --- -- - - _ EXISTING RACE TRACK ' _,.._-_ _-__ ....-. -_- CONTROL■�.. __.._ _ _ PROPOSED RACE ._ CONTROL BUILDING.. �• AND SKY BRIDGE FUTURE PAVED EXISTING ASPHALT / / PADDOCK AREA _---� OWING 4'ODE BY 240'LONG BY 4' -- - DEEP,OPEN TOP INFILTRATION' EN TRCH. - ��PADDOCK AREA SEE,DETAIL ON SHEET C2.4,,. > ' �J I EXISTING TYPE 2 CATCH ,y1� 34'126'PORMBLE IRDG. N _ ." BASIN W/INLET GRATE RIM-327.0 ! EXISTING 4' BY 160'LONG BY 4 ;. P PAD 44'x,10'9,700 SF `` IE-322.1 (EX 1�%N) DEEP TOP INFILTRATION TRQJCN.- - 2CRY PERFORMANCE o 1E�32Z1 (NEW 2'S) SEE AIL ON SHEET C2.4.,-. CENTER BLOC. \- F i, - ..---...■- RESTROOMS T. sc l7GSRNG .. 30",,6 CONCRETE PAD /./ _ _— _ _ -32,r VF Sao-KAR T TRAGIC GRWROUND FUEL TAN / II / EXISTING A PHALT NEW OIL-WATER I I w l F• SEPARATOR I ( S GO-KART PAD OCK ARE { I I w FL RVED I; IS URE P TDOCK A r - REA __ PROPOSED EX SEPTIC C I` $HOP 7l a y� . 7REATMENT PROPOSED D /' g I I \•\`�-- T — -- k — x — — x- —x—x— xTx—x x— —.Ir—_— - _x XT■---x x —_FUTURE TRACK D MAINTENANCE SHOP WEST EELLS HILL ROAD AND TRACK GARAGE PROPOSED STORM INFILTRATION BASIN FUTURE STORM TREATMENT BASIN EXISTING ADMINISTRATION OFFICE FUTURE MAIN ACCESS DATEa 10 201s C THE RIDGE MOTORSPORTS PARK JOiaos80 Engineering Aim N� �Qrp F GRADING AND DRAINAGE DESIGN pxA140VANG 0 DIAL ENGNEERING-LAND PLANNING-UTIUTIEs df _ _ MASON COUNTY, WA. SEC 4, TWP 20 N, RGE 4 W. W.11. 14050 GRPL1 W.(M;7I0-09 C2.1 "CALL UNDERGROUND LOCATE AT 811 BEFORE YOU DIG" aaw�1lA � FLF(AD)Ia e1I2 N0. DATE REVISION �,� GRADING AND DRAINAGE PLAN WEST 2 OF 5 RIDGE MOTOR SPORTS PERMIT REVIEW COMMENTS & RESPONSES DATE: January 29, 2019 ATTN: Tricia Woolett, Mason County Building Inspector/Plan Review 1. In our office plan page C2.2 was damaged. Please email this page to replace previous. RESPONSE: C2.2 is provided. 2. Page CS.1 must be updated with changes and proper exiting paths. RESPONSE: CS.1 has been updated with revised exit path and life safety notes showing (2) exits from all required spaces. (Revised sheets CS.1,A2.2,A3.2, A9.1) 3. Page A2.2 the detail label for the restroom is incorrect. Please correct. RESPONSE: The detail call out has been updated to call out the correct sheet number. (Revised sheet A2.2) 4. The horizontal continuity must be addressed in accordance with IBC Section 705.5. RESPONSE: The floor and supporting structure for the floor are required due to the Fire Area allowed by the County (5,000 SF). A 2-hour horizontal assembly (Fire Barriers Section 707) has been designed per section 707.3.10 and table 707.3.10. The supporting structure (columns and floor structure)is required to meet the same 2-hour fire rated requirement and is detailed as such 7 in the permit submittal. The fire assembly is continuous from the slab to the 2-hour assembly at the floor. The floor assembly is continuous from non-combustible metal exterior skin to non- combustible metal exterior skin on all sides. The exterior wall is not part of the supporting structure for the horizontal assembly of the second floor,furthermore the exterior walls are more than 10' from property lines on all sides and are not required to be rated due to fire separation distance per 705.5,table 601, and 602 (II-B construction). (No drawing revisions) 5. The detail for the walkway, on page A/A6.2 refers to MBM drawings? Please provide details, engineering and plans. RESPONSE: In the submittal drawings section A/A6.2 calls the exterior walkways as being designed by the Structural Engineer, Drawings and Calculations were submitted. The mezzanine floor is by MBM and is called out accordingly, Drawings and Calculations were submitted. (No drawing revisions) 6. Plans note a retaining wall. Must provide details, plans and engineering for the wall. RESPONSE: The retaining wall is an existing structural wall that is already constructed and has been approved by the county under permit number COM2015-00076. All documentation including designs and engineered documentation are included with the county records. We have also included some of the documentation for your reference. (No drawing revisions) 7. Lighting, plans must include details in accordance with C406.4#5. RESPONSE: The supporting electrical documents represent the requested plans in accordance to C406.4#5. Supporting documents include Lighting Controls Layout along with the Lighting, Motor, and Electrical permit checklist. Supporting documents are an inclusion with our initial Lighting Summary submitted on November 14, 2018 8. The flex area will require panic hardware. Update door/hardware table. RESPONSE: In the permit submittal Doors 101A(HW1)&101D(HW3)both are equipped with panic hardware per sheet A9.1. (No drawing revisions) 9. Plans must include details for WSEC C402.5.1 Air leakage/Air Barrier. RESPONSE: A note stating the air barrier and air leakage requirements has been added to the Title Sheet. (Revised sheet TITLE) 10. See page A9.1 Doors and Hardware note ##1 and Window types note. Compare to Component Performance on the last page. They do not match. Please revise plans to match the Component performance for doors and windows. RESPONSE: The callouts on the window and door schedule have been revised to match the Envelope Summary in the permit submittal. (Revised sheet A9.1) All revisions required by the permit comments are bubbled and noted with a flag note #1. Owner changes have been bubbled and noted with a flag note#2. Those owner changes include: • The owner has revised the location of the west wall in Prep 203 due to the new exit path in order to gain area back for Catering 202. • The mechanical cabinet was omitted in Banquet Hall 201,this omission required the north wall to move 1'10" to the south to assure the SF/Occupant Load is under the 100 occupant load which requires a sprinkler system in that space. Please contact us if you have any questions on our responses and/or have any further requirements. Thank you for your time on this project. NEIL A MEYER, RA,AIA I PRESIDENT 9135 FIL ISTERED C ECT Lonnie S. Hetzler, Kaufman Construction YER STAASHINGTON MEYARCHITECTURE 2626 Country Clue Road NW I Olymoi;..VVA 98602 Rhone 360.701.4706 low I i 0 SW J_ bl�l f �l J Y A4ason County Community Services Building Dlvision SPECIAL INSPECTION & 6 Alder Shee ltoniton,, WA 98584 et 52 TESTING AGREEMENT www.co.ma5on.wa.us (Afin*1V ces are per the 2015 Intemctionrol Building Code) Project Name: Au &070A 6pyt � 692 Project Address: f!1 Le 1 f ELLS L�! c.L t J` r L 1' r L!V,4- f� Building Permit Number. Date issued: WQgE A PETtMR CAN BE tnU The registered Design Professional in responsible charge shall fill out the Agreement and include the name and address of the company or inspector. Two (2) copies of this form are to be submitted to the County prior to the Issuance of a building permit, if changes are made as to who will perform the special inspections a new form shall be submitted and turned into the Building Permit:$&inspections Division for approval. STATEMENT OF SPECIAL iNSPECtibNS; In addition to this Agreement, a "Statement of Special inspections" shall be provided per IBC 1704-2. This Statement shall be made as part of the approved plans, and be placed in a conspicuous location,such as the first page of the construction plans or the first page of the structural sheets. SPECIAL 11WECTORS: All special inspectors shall be approved by the Building Division prior to performing arty dunes. The special inspector shall provide proof of certification as a special Inspector for each inspection item and be licensed by the State of wasbington. SPECIAL INSPECTION REPORTS: Special inspection reports are to meet the requirements of IBC 1704.2.4, Coples of each report are to be sent to the address listed in the kMvrhead noting the Project Address and Permit Number. A final report shall be submitted sating that all special Inspection and structural testing items were compieted and are in conformance with the approved design drawings and specifications. items not in conformance,unresolved items,or any discrepancies in inspection coverage(i.e. missing inspections, periodic inspections when continuous was required,etc.)shall be specifically Itemized in-thefinal report- Areas requiring special inspection: Name of AgencIr. Address&Corrtact Informatior Unapproved Fabricators(IBC 1704.2.5) `G L A1'7 C f 6T44. v BcZC4cJ, Other than Structural Steel(IBC Table 1705.2.2) Narcriais T cuing§Consulting;?71A Bkeci T..aice Blvd,Oiyrnpia,WA 485 t'. 3 Steel floor&roof decks has bccn retained to prnmdc all bean Ramsdel! VP required inspection.and 36C.75S.6080 ❑ welding of reinforcement matorial.testing ❑ Gold-formed steel Structural Steel i--� k 7-e- 29 Welding(Per NSA of RISC 35G-LO) Ll Details(Per N5.7 of AISC 36&10) F) High-strength bobs(Per N5.6 of AiSC 360-10) Concrete Construction(per 18C Table 1705.3) N rG " 7G ® Reinforcement,embeds,anchors Formwork materiais ❑ 5hotcrete L7 Post-tensiorled/Pre-stressed Concrete 13 Erection of precast concrete Page 1 of 3 Mason County Community Services Building Division SPECIAL INSPECTION & n, WA Stye 9858 Shelton, WA 4 4 et . n TESTING AGREEMENT www.camasa .wa-us Areas requiring special Inspection: Name of Agency* Address&Contact Information Masonry Construction(IBC 1705.4) ❑ Prior to Constriction(Artkie 1.15,TMS-602) ❑ As Construction Begins(Aitkie 1.19-2,TMS402) ❑ Prior to Grouting(Table L15.2,TM5-402) ❑ During Construction(Per TM5-402&TM5-602) Wood Construction ❑ Highl.oad Diaphragms(IBC 1705.5.1) ❑Wood Trusses>60ft(IBC 1705.5.2) ll Soils(I BC Table 1705.6) Ml L ❑ Driven Deep Foundations(IBC Table 1705.7) ❑ Cast-in-place Deep Foundations(IBC Table 17054) ❑ Helkal Pile Foundations(IBC 1705.9) D sprayed Flre-Resistant Materiah(IBC 1705.13) ❑ Mastic&Intumescent Coatings(IBC 1705.14) ❑ EIFS(IBC 1705.15) ❑ Fire-Resistant,Penetrations(IBC 1705.16) ❑ Smoke Control(IBC 1705.17) 12 structural steel(IBC 1705.12.1&AiSC 341-10) Af r4 — Sep� ";,c A VIA6 ❑ Structural Wood(IBC 1705.12.2) Page2of3 i ti Mason County Community Services Building Division 615 IN Alder Street SPECIAL INSPECTION & Shelton, WA 98584 9D 360.427-9670 ext.352 TESTING AGREEMENT www.co.mason.wa.us ❑ CoWformed steel VBC 1705.12.3) ❑ Mechanical&Electrical Components(170S.12.4) ❑ Architectural Components(1BC 1705.1.25) ❑ Storage Racks(19C 1705.12.7) Post-Installed Anchors(ISC17Q5-Li) [A Other d Structural observatkms Declaration by Archhect/Engineer 1, the design professional in responsible charge for this project, declare that the above listed special inspection and structure .items are required for this project in accordance with IBC Chapter 17. Nam Sigr4mm 02.21,2019 Date siptature (Gecia&t) Date Declaration by Owner 1,the Owner of the project,declare that the above listed firm(s)or individual(s)are hired by me to perform special inspection nd structural testing fo a project pursuant to IBC 1704.2. q _ 2) � wa signature CONTRACTOR RESPONSIBILITY: Each contractor involved with the construction of wind or seismic force-resisting systems shall comply with the requirements of IBC 3.704.4. The contractor is responsible for providing the special inspector access to approved plans and contract documents at the job site. All special Inspection records shall be retained at the Job site by the contractor and shall be made available to the Building Department upon request. Declaration by Geneml Contractor I,the General Contractor of the project,agree to campiy with the"Contractor Responsibility'Rents noted above. Date Signature Page 3 of 3