BLD2024-00115 Solar - BLD Inspections - 5/28/2024
INSPECTION CARD Mason County 615 W. Alder St. N Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# BLD2024-00115 PROJECT ADDRESS 23430 N US Highway 101 Hoodsport, WA 98548 PARCEL# 422144100160 PROJECT DESCRIPTION NEW PV SYSTEM: 6.150 kWp OWNER SEAVIEW HOODSPORT LLC ADDRESS 1329 N NORTHLAKE WAY PHONE 206.304.1477 CONTRACTOR SMART SOLAR ENERGY CO ADDRESS 10940 SW Barnes Rd#250 PHONE 971-645-2487 CONTRACTOR LICENSE SMARTSE783BK LENDER INSPECTION I P YATE, Comments INSPECTION INSP DATE Comments BLD-Final Inspection �-�� J-o.�� J�I N,�Z� '.,� �L.G�-P�Gw( N t11- �O+►�ls.�t, $-c,�,14�!" ��(�L to �0 ( �.-�Z �► 3VI MASON COUNTY 360-427-9670 Shelton ext. 352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: E Lo 202q —W1l�f ADDRESS/LOCATION: 2343o W , us 0_ux. lot FINDINGS: C1 1-4 z i1'k- ►2c.6�1 of^- 0� .U.e,,,. G,nn1.1- 0,44: ,,. IX:., Items listed above must be corrected to lain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑X OK to Steal ?L%ao o Date: 5-11 q Please contact our office regarding possible Department: 13 I.p structural damage incurred by recent Inspector:_ "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov BLD2024-00115 ROOF MOUNT SOLAR PANEL- RESIDENTIAL PROJECT DESCRIPTION: NEW PV SYSTEM: 6.150 KWP ISSUED: 02/21/2024 SITE ADDRESS: 23430 N US HIGHWAY 101 HOODSPORT EXPIRES: 08/19/2024 PARCEL: 422144100160 APPLICANT: SEAVIEW HOODSPORT LLC OWNER: SEAVIEW HOODSPORT LLC 1329 N NORTHLAKE WAY 1329 N NORTHLAKE WAY SEATTLE,WA 98103 SEATTLE,WA 98103 206.304.1477 CONTRACTOR: SMART SOLAR ENERGY CO 10940 SW Barnes Rd#250 Portland,OR 97225 971-645-2487 GENERAL CONTRACTOR'S LICENSE: SMART SOLAR ENERGY CO License: SMARTSE783BK 10940 SW Barnes Rd#250 Expires: 01/12/2026 Portland,OR 97225 971-645-2487 FEES: Paid Due Technology Surcharge $1.60 $0.00 Final Inspection $80.00 $0.00 Solar/PV Fee $19.00 $0.00 Solar/PV Base Fee $30.00 $0.00 State Fee-Residential $6.50 $0.00 Totals : $137.10 $0.00 REQUIRED INSPECTIONS BLD-Final Inspection CONDITIONS Printed by:Nikita Huckabey on:04/03/2024 11:50 AM Page 1 of 3 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-00115 " The installation of solar(thermal or photovoltaic)energy systems to provide space heating or cooling, hot water and swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code, the International Fire Code, and be shall be listed and labeled in accordance with UL1703. Roof mounted panels shall weigh no more than 4 Ibs per square foot. Supports for solar panels are to be installed to spread the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-lbs are created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the inspection by the Mason County Building Inspector. Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings. Not less than two-3-foot wide access pathways shall be provided from the eave to ridge. Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection. Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight,collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector. Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit. Solar energy collectors, controls, dampers,fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials,flashed and sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for inspection. All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Printed by:Nikita Huckabey on:04/03/2024 11:50 AM Page 2 of 3 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.mason cou ntywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-00115 Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: Date: Printed by:Nikita Huckabey on:04/03/2024 11:50 AM Page 3 of 3 A B C D E F G H GENERAL NOTES 1 1. FIELD VERIFY ALL MEASUREMENTS SMART 2. REMS BELOW MAY NOT BE ON THIS PAGE ----PROPERTY LINE ENERGY CONTRACTOR SMART SOLAR ENERGY 2 UTILITY POLE METERIMAIN PHONE: 971-645.2467 ADDRESS: 10940 SW BARNES RD 11M, \ PORTLAND,OR 97225 AC LOAD CENTER \ AC DISCONNECT NON-FUSED LIC.NO.: 234657 ENTRANCE AREA OF WORK HIC.NO.: ELE.NO.: 5 9'O" UNAU HJR ZEDISEOFIMR JD-U DRAMNG SET N1TlgUf WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS n AND N1LL BE SUBJECT TO CIVIL l MN/LES AND PROSECUTIONS 51'-5" 51'-5" NEW PV SYSTEM:6.150 kWp PITT I RESIDENCE 23430 US-101, HOODSPORT,WA 98584 APN:422144100160 4 I ENGINEER OF RECORD I i 5 ( I PAPER SIZE 11,'.]"IANSI B! SITE PLAN DATE:01.24.2D23 DESIGN BY:E.T. CHECKED BY: M.M. SITE PLAN N 6 01 REVISIONS W�E 0 32' 64' ® 5 A-101,00 A 8 C D E F G H OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed in this Checklist. All project plans and supporting documentation must be provided on site for the inspector. --------TO BE COMPLETED BY APPLICANT------- © Project Information Property Owner Name: David Pitt & Seaview Hoodsport Ilc Project Address: Parcel# 23430 N HWY-101 422144100160 City: State. ZIP: Hoosport WA 98584 Day Phone: 206 -304 -1477 Contractor Name Smart Solar Energy & Unity Electric Contractor License#: SMARTSE783BK Contractor day phone: 9716452487 Describe project: Conventionolfromed built dwelling or garage, NEW ROOFTOP PV SYSTEM: 6.150 kWp Pole structure,steel building,etc. Note: Manufactured/mobile homes require L&I Approval PV system description STC: 16 X 410W = 6.560KW (include manufacturer PTC: 16 X 385.2W = 6.163KW and model#of PV (16) SILFAB SOLAR SIL-410 HC+ modules and (8) APS DS3-S inverters): ©Determine if your project qualifies for expedited permitting: Yes No 1. PV system is designed and proposed for a detached one-or two-family dwelling or townhouse not more than three stories above grade or detached accessory structure that ❑ is code compliant to setbacks and height, or code allows expansion of nonconformity for solar modules. [IRC 101.21 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by 0 ❑ the local jurisdiction. 3. Rooftop is made from lightweight material such as a single layer of composition shingles, E ❑ metal roofing, lightweight masonry,or cedar shingles. 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.21 0 ❑ 5. The installation shall meet the requirements of NFPA 70 National Electric Code, and all required electrical permit(s) must be obtained from the Authority Having Jurisdiction to [z] ❑ administer the electrical code. [IRC M2302.2] 6. The installation shall meet the requirements of the International Fire Code as amended El ❑ by WA State. [IRC M2302.2] 7. The PV system is designed for the wind speed of the local area, and will be installed per El ❑ the manufacturer's specifications. [IRC M2302.2.1(1)1 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] El ❑ 9. Total dead load of modules, supports, mountings, raceways and all other appurtenances ❑ weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] 1 Enter total dead load of system (Ibs/ft): Click here to enter text. 10. To address uplift,modules are mounted no higher than 18" above the surface of the 0 ❑ roofing to which they are affixed. [IRC M2302.2.1(4)] 11. Supports for solar modules are installed to spread the dead load across as many roof- framing members as needed to ensure that no point load exceeds fifty (50) pounds. p ❑ [IRC M2302.2.1(5)] 12. The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for ❑ the roof construction. [IRC M2302.2.1] 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, ❑ rodents, and insects. [IRC M2302.2.2] 14. PV modules are listed and labeled with a fire classification in accordance with UL 1703. 0 ❑ [IRC M2302.2.31 Comments: If you answered yes to all of the above questions, the project qualifies for the over-the- counter permitting process. © Submit this Checklist, Site Plan, and other required permit application forms to: [insert contact info for jurisdiction having authority] yAs the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: Date: 1/25/24 Applicant Name (Please rmt): Jenn Showers --------TO BE COMPLETED BY MASON COUNTY STAFF------ Qualifiesfor OTC Building Permit? ❑Yes ❑No Permit Application#: Staff Initials Date: 2 ' 4 MASON COUNTY COMMUNITY SERVICES Permit No: PERMIT ASSISTANCE CENTER: •BUILDING •PLANNING •FIRE MARSHAL ;f 615 W.Alder St-Shelton, WA 98584 www.co.mason.wa.us Phone Shelton:(360)427-9670 ext.352• Fax.(360)427-7798 Phone Belfair.•(360)275-4467• Phone Elma:(360)482-5269 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:David Pitt NAME:Smart Solar Energy&Unity Electric MAILING ADDRESS:23430 N HWY 101 MAILING ADDRESS:10940 SW Barnes Rd#250 CITY:Hoodsport STATE:wA ZIP:98584 CITY:Portland STATE:OR ZIP:97225 Is'PHONE:206-304-1477 PHONE:971-645-2487 CELL: 2nd PHONE: EMAIL :projects@smartsolarenergy.co EMAIL:dave@affinityventuresnw.com L&I REG#604688107 EXP. 12/2025 / PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):422144100160 Zoning: LEGAL DESCRIPTION(Abbreviated): SITE ADDRESS:23430 N HWY 101 CITY:Hoodsport, DIRECTIONS TO SITE ADDRESS: TYPE OF JOB: NEW=ADD=ALT=REPAIR=OTHER=USE OF BUILDING LOCATION OF FIXTURES/UNITS—1 ST FLOOR=2ND FLOOR=BASEMENT=GARAGE[---]OTHERO PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Tyne of Fixture No.of Fixtures Fees Fuel Type:Electric=PG=Natural Gas=Ductless= Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heat Pump Showers _ Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hose bibs _ Dryer Vent Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X �R.vw Prft 1/25/24 Signature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 JBN A B C D E F G H GENERAL NOTES NEW PV SYSTEM: 6.150 kWp SHEESHEET NUMBER IST TAB LE EETTITLE . 1.1.1 PROJECT NOTES: 1 1.1.2 THIS PHOTOVOLTAIC O'V)SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE CTIO ARTICLE 690,ALL ANT CODES AS S P LISTING AND E AUTHORITYATION T-00PITT RESIDENCE G-W1.00 COVER PAGE INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY LAIR HAVING JUIBSDICTIONS(AH,APPLICABLE CODES. G-001.00 NOTES ENERGY 1.1.3 THE UTILITY INTERCONNECTION APPUCATION MUST BE APPROVED AND PV SYSTEM A-101.00 SITE PLAN INSPECTED PRIOR TO PARALLEL OPERATION 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION(GFDI)DEVICE IS INTEGRATED A-102.00 ELECTRICAL PLAN WITH THE MICRDINVERTER IN ACCORDANCE WITH NEC 690.41(B) 23430 US-101 CONTRACTOR 1.1.5 ALL PV SYSTEM COMPONENTS:MODULES,UTILITY-INTERACTIVE INVERTERS,AND J A-103.00 SOLAR ATTACHMENT PLAN SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND USTED FOR USE IN HOODSPORT WA 98584 E40I.00 LINE DIAGRAM SMART SOLAR ENERGY 2 PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV MODULES:UL1703,IEC6173D,AND IEC61215,AND NFPA 70 CLASS CFIRE 1 E402.00 DESIGN TABLES COMBIERS:LA 1741 CERTIFIED,UL 1741 ACCESSORY 9 ASSESSOR'S#: 42214410016 0 PHONE: 97144E-2487 COMBINER BOX(ES):UL 17030R UL 1741 ACCESSORY E403.00 PLACARDS ADDRESS: 10940 SW BARNES RO I250, 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP S401.00 ASSEMBLY DETAILS PORTLAND,OR 97225 COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC69D.7. 1141.00 RESOURCE DOCUMENT 1.1.7 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND SOURCE III LIC,NO,: 234657 CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL R-002.00 RESOURCE DOCUMENT HIC.NO.: THIS BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 P).SHALL BE •41Mr; ELE.NO.: INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING NEC -,� R-003.00 RESOURCE DOCUMENT uNAuANGSE; USE OF MI 110.3G 4" f R-0MAD RESOURCE DOCUMENT oRAvnNc servnnaur wRirrEN 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE.IF �, PERMISSION FROMCOrmucrORISIN EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE VIOIATON OF U.S.COPYRIGHT LAWS ANDW LBESUBJECTTOCNIL 3 WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. � DAMAGES AM PROSECUTIONS 11.1 SCOPE OF WORK: 43." NEW PV SYSTEM:6.150 kWp 12.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT.PRIME CONTRACTOR WILL BE PITT RESPONSIBLE FOR COLLECTING COSTING ONSITE REQUIREMENTS TO DESIGN, - -- SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. - W RESIDENCE r 1.3.1 WORK INCLUDES: 23430 US-101, 1.3.2 PVROOFATTACHMENTS-SUNMODORANOMOUNT --- -- PROJECT INFORMATION 1.37 PVRACKINGSYSTEMINSTALLATION-SUNMODO SMR10D HOODSPORT,WA98584 1.3.4 PVMODULEANDINVERTERINSTALLATION- OWNER APN:422144100160 SILFAB PRIME SIL410 HG IAPS DS3S AERIAL PHOTO NAME: DAVID PITT 4 1.3.5 PV EQUIPMENT GROUNDING PHONE ENGINEER OF RECORD 1.3.6 PV SYSTEM WRONG TO A ROOF-MOUNTED JUNCTION BOX NOT TO SCALE E-ALNI: 1.3.7 PV LOAD CENTERS OF INCLUDED) PROJECT MANAGER 1$B PV METERINGAJONITORING OF INCLUDED) 1.3.9 PV DISCONNECTS NAME: JENN SHOWERS 1.3.10 PV GROUNDING ELECTRODE A BONDING TO(E)DEC PHONE: 9716452487 1111 PV FINAL COMWSSIONING CONTRACTOR 1.3.12(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV NAM E: 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE NAME: SMART SOLAR ENERGY PHONE: 971L45.2487 AUTHORITIES HAVING JURISDICTION BUILDING: HDODSPORT,WA _ ZONING: HOODSPORT,WA 5 UTILITY: MASON COUNTY PLO PAPER SIZE II•slr(as6) J� (LESION SPECIFICATIONS OCCUPANCY: II COVER PAGE CONSTRUCTION: SINGLE-FAMILY SCOPEOFWORK ZONING: RESIDENTIAL DATE:01.242023 SYSTEM SIZE: STC:15X41OW=6.15OKW GROUND SNOW LOAD: 15 PSF FTC:15X 387.04W=5.BNKW WIND EXPOSURE: D DESIGN BY:E.T. (15)SILFAB PRIME SIL410 HG WIND SPEED 110 MPH (8)APB DS3S CHECKEDBY: M.M. APPLICABLE CODES B STANDARDS PLAT MAP N BUILDING: IBC 2018,IRC 2018 REVISIONS 6 02 � ELECTRICAL: NEC 2018 ATTACHMENT TYPE SUNMDDO NANOMOUNf w E FIRE. IFC 2018 NOT TO SCALE MSPUPGRADE: NO 9 T-001,00 A B C D E F G H A B C D E F G H 2.1.1 SITE NOTES: 2.5.6 EACH MODULE WILL BE GROUNDED USING WEER GROUNDING CLIPS AS SHOWN IN 2.12 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEKS ARE NOT USED, 1 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. SMART 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING 25.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL ROOF VENTS. OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL 2.5.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLORED GREEN OR ENERGY EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. MARKED GREEN IF M4 AWG OR LARGER(NEC 250.1191 2.1.6 ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH 2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 25050 THROUGH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF 250,106.IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,A GROUNDING ELECTRODE CONTRACTOR COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 AND AHJ. 23.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(BNi)THROUGH(3)TO REDUCE SMART SOLAR ENERGY 2 22.1 EQUIPMENT LOCATIONS: FIRE HAZARDS 222 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC110.26. PHONE: 971-645.2487 22.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING 2.6.1 DISCONNECTION AND OVERCURRENT PROTECTION NOTES: ADDRESS: 10940 SW BARNES RD I250, TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C)AND NEC TABLE 310.15(B)(1). 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE PORTLAND,OR 97225 22A JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED'LINE 690.34. SIDE'(TYPICALLY THE UPPER TERMINALS). 225 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE LOCKABLE,AND BE A LIC NO.: 234657 SIGHT OF THE AC SERVICING DISCONNECT. VISIBLE-BREAK SWITCH NO.: 22.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPT)SHUTDOWN HIC.HIC.ELE NO.: NEC APPLICABLE CODES. FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH I,wAUrHORIZE USE OF TINS 22.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN 690.12(A)THROUGH(D). DRAMIXI SETIMITHOUT VRITTFN APPROPRIATE. 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9,AND 240. PERMISSION FROM CONTRACTOR IS IN VIOLATION OF Us.ODPYROIT LAVA 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN AND VILL BE SUSIECT TO CIVIL 3 2.3.1 STRUCTURAL NOTES: ACCORDANCE WITH NEC 110.30). 01MAGES AND PROAEWICNS 2.32 RACKING SYSTEM&PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT 2.6.7 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEW PV SYSTEM:6.150 kWp INSTALLATION MANUAL.TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, NEC 690.11 AND UL1699B. AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE PITT ARRAYSUBARRAY,ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. 2.7.1 INTERCONNECTION NOTES: 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH NEC 7D5.12 ROOF-PENETRATING TYPE,IT SHALL BE FLASHED&SEALED PER LOCAL REQUIREMENTS. 27.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RESIDENCE 23.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WI APPROVED RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 CHEMICAL SEALANT PER CODE BY LICENSED CONTRACTOR, PERCENT OF THE ANIPACITY OF THE BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE 23430 US-101, 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD NEC 705.12(B)(3)(2)1 HOODSPORT,WA 98584 SPECIFIED BY THE RACKING MANUFACTURER. 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL,TOTAL RATING OF ALL 2.3.6 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE APN:422144100160 THE ROOF FRAMING MEMBERS. COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12(BH3)(3). ENGINEER OF RECORD 2.7.5 FEEDER TAP INTERCONNECTION(LOAD SIDE)ACCORDING TO NEC 705.12(B)(1)AND(2) 2A.1 WIRING&CONDUIT NOTES: 2.75 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.11 WITH SERVICE ENTRANCE 2A2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND CONDUCTORS IN ACCORDANCE WITH NEC 230.42 WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT 2.1.1 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM TO LIMIT UP-SONG. ADDITIONAL FASTENING NEC 705.12(Q. 2.43 CONDUCTORS SIZED ACCORDING TO NEC 6903,NEC 690.7. 2AA VOLTAGE DROP LIMITED TO 1.5%. 2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WI SUITABLE WIRING CLIPS. 2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1-BLACK PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE 5 PHASE C OR 1.3-BLUE,YELLOW,ORANGE",OR OTHER CONVENTION PARER sue,I m(ANSI eI NEUTRAL-WHITE OR GRAY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED NOTES ORANGE NEC 110.15. 2.5.1 GROUNDING NOTES: DATE:01.24.2D23 232 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DESIGN BY:E.T. DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.53 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 69D.43 AND MINIMUM NEC TABLE CHECKED BY: M.M. 250.122. 6 2.5A METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ENCLOSURES CONSIDERED REVISIONS GROUNDED IN ACCORD WITH 250.134 AND 250A36(A). 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICROINVERTER MANUFACTURERS'INSTRUCTIONS. r_0 01.0 0 A 8 0 D E F G H v A B C D E F G H GENERAL NOTES 1 1. FIELD VERIFY ALL MEASUREMENTS SMART 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ————PROPERTY LINE ENERGY CONTRACTOR SMART SOLAR ENERGY 2 UTILITY POLE METERIMAIN PHONE: 971fi45-2487 ADDRESS: 10940 SW BARNES RD#250, \ PORTLAND,OR 97225 AC LOAD CENTER \ AC DISCONNECT NON-FUSED LIC.NO.: 234657 ENTRANCE AREA OF WORK H NO ELELE.NO.: 59'-8" UNAUTNORIZED USE OF TMS DRAMANG SET WITNDO W TTEN PERMISSION FROM CONTRACTOR IS IN V OLATICN OF US COPVRIGW LAMS 3 AND'MLL BE SUBJECT TO CML DAMES AND PROSECUTIONS, 51'-5" 51'-5" NEW PV SYSTEM:6.150 kWp I PITT RESIDENCE 23430 US-101, HOODSPORT,WA 98584 APN:422144100160 4 I ENGINEER OF RECORD I I 5 I I PAPER SIZE:11'x 17'(ANSI B) SITE PLAN DATE:01.24.2023 DESIGN BY:E.T. CHECKED BY: M.M. N SITE PLAN 6 01 REVISIONS iBd_1-0. D® WTE S A B C D E F G H A-101.00 A B C D E F G H GENERALNOTES 1 (E)(1)METERIMAIN 1. FIELD VERIFY ALLNEASUREAENTS SMART UTILITY POLE 2. ITEMS BELOW MAY NOT BE ON THIS PAGE FIRE CLEARANCE ENERGY OMODULE STRINGING CONTRACTOR OMODULE STRINGING SMART SOLAR ENERGY 2 PHONE: 971645.2487 ADDRESS: 10940 SW BARNES RD M2W, 18"FIRE ACCESS PATH PORTLAND,OR 97225 18"FIRE ACCESS PATH I.C.NO.: 234657 HIC.NO.: ELE.NO.: UNAUTHORIZED USE GF THIS DRAMNG SET MAHOUT WR17TEN INTERIOR PV EQUIPMENT T FIRE ACCESS PATH PERMS NOFOPON FROM rRIGW LAM (E)(E)(1)MAIN ELECTRICAL PANEL G D WILL OF U.S.U.COPYRIGHT uws 3 EXTERIOR PV EQUIPMENT (NI JUNCTION BOX ARRAY 3-0.820 KW DAMAGES ANDBE PROSECBJECT TO UTIONS. -DAMAGES AND PROSECURONS (N)(1)AC DISCONNECT NON-FUSED IX2I(N)MODULES (N)(1)AC LOAD CENTER TILT:45 DEGREES NEW PV SYSTEM:6.150 kWp ROOF PITCH:12:12 AZIMUTH:90 DEGREES P ITT B B ❑ ARRAY 1-4.100 KW DEGREES MODULES TILT:25 RESIDENCE TILT: ROOF PITCH:6:12 B B A71MUTH:90 DEGREES 23430US-101, B B ARRAY 2-1.230 KW HOODSPORT,WA 98584 A B [Y3I(N)MODULES APN:422144100160 TILT:45 DEGREES 4 A A ROOF PITCH:12:12 ENGINEER OF RECORD AZIMUTH:90 DEGREES A A A A A 3'FIRE ACCESS PATH 5 PAPER SIG:n,z Ir(AM B) ELECTRICAL PLAN 40.8" I DATE:0124.2023 MODULE: DESIGN BY:E.T. SILFAB PRIME CHECKED BY: M.M. N ELECTRICAL PLAN 753" SIL-410HC+ REVISIONS W N 6 01 410 WATTS ® 5 A-102,00 A B C D E F G H A B C D E F G H GENERAL NOTES 1 1. FIELD VERIFY ALL MEASUREMENTS SMART 2. ITEMS BELOW MAY NOT BE ON THIS PAGE -RDOFTRUSSES FLUSH MOUNT SOLAR MODULES ENERGY ATTACHED TO ROOF SURFACE(SEE __________ SHEET SLO1.00 FOR MOUNTING DETAILS) CONTRACTOR SMART SOLAR ENERGY PHONE: 971445-2487 ADDRESS: 10940 SW BARNES RD#250. PORTLAND,OR 97225 LIC.NO.: 234657 ---------- ELE.NO.: ———— ——— UNAUTHORRED USE OF THIS DRAWNO SET W,THOUT WRITTEN __ __ PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS AND I LL BE SUBJECT TO CML 3 DAMAGES AND PROSECUTIONS. ---- 2X9"TRUSSES @24"O.C. --- NEWPVSYSTEM:6.150kWp _ ROOF ATT.TYP.@48"MAX. ---- -_- 1T-1" PITT --- -_-__-- RESIDENCE _ 23430 US-101, HOODSPORT,INA 98584 APN:422144100160 4 ❑ 6-10" ENGINEER OF RECORD 5 ROOF MATERIAL IS ASPHALT SHINGLE vASBRsm I r.Ir WO BI 40.8" SOLAR ATTACHMENT PLAN ICI DATE:01.242023 MODULE: DESIGN BY:E.T. N SILFAB PRIME CHECKED BY: M.M. 6 SOLAR ATTACHMENT PLAN W 75>" SIL-410HC REVISIONS ff]01 -0 ® A B C D E F G H A-103.00 A B C 0 E F G H CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CURRENT-CARRYING TEMP.CORR. CONDUIT FILL CONT. MAX.CURRENT DERATED 1 ID TYPICAL CONDUCTOR CONDUIT CONDUCTORS IN CONDUIT OCPD EGC FACTOR FACTOR CURRENT (125%) BASE AMP. AMP TERM.TEMP.RATING AMP.@ TERMINAL I SMART 1 1 10 AWG THWN-2,COPPER 0.75'DIA PVC40 4 20A 10 AWG THWN-2,COPPER 0.96(31.1'C) 0.8 10.64A 13.3A 40A 30.72A 75'C 35A 2 1 10 AWG THWN-2,COPPER 0.75'DIA P/C-0(1 2 N/A 10 AWG THWN-2,COPPER 0.96(31.1'C) 1 21.28A 26.6A 40A 38.4A 75'C 35A 3 1 10 AWG THWN-2,COPPER 0.75'DIA PVC-40 2 30A 10 AWG THWN-2,COPPER 0.96(31.1'C) 1 21.28A 26.6A 40A 38AA 75'C 35A ENERGY TO UTILITY O MODULE STRINGING GRID(UG) CONTRACTOR O A^^ SMART SOLAR ENERGY 2 MODULE STRINGING PHONE: 971845.2487 L2 ADDRESS: IOW SW BARNES RD#250, NA PORTLAND,OR 97225 L1 (E)UTILITY METER LIC.NO.: 234657 r(320 ATING:400 AMP MAX. HIC,NO.: AMP CONTINUOUS) ELE,NO.: "UnaRIZEo USE OF THIS DRAWINGSET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN PV SYSTEM EQUIPPED WITH RAPID wO WILLBE U.s.coPOWLUWrs 3 AND W1Ll SE SURIECT TO CML SHUTDOWN DISCONNECT PER NEC 690.12 r——————— — —1 DAMAGES AND PROSECUTONS. (N)(15)SILFAB PRIME SYSTEM COMPLIANT WITH NEC 690.13 I I NEW PV SYSTEM:6.150 kWp SIL-410 HC+ PITT 410 WATTS (N)AC LOAD CENTER,125A (E)MAIN N G I(E)MAIN N G I 120/240V,10,3W 200A I 200A I (E)METER/MAIN RESIDENCE (N)(8)APS DS3-S I I 23430 US-101, 240/120 V 10,3W HOODSPORT,WA 98584 I I MAIN BUSS:400A APN:422144100160 a (N)JUNCTION BOX I I ENGINEER OF RECORD I I I I I (N)AC DISCONNECT I GROUND 20A NON-FUSED,60A I ROD $ iiiiiiisHHHEH HEM — IN BRANCH &acN I (E)MAIN N G I (E)MAIN N G (E)GROUNDING I I 200A I 200A ELECTRODE 5 O - - --- cm) I I 20A 2 ® 3 N ® PAPER SIZE I r n(ausl sl ( ) LINE DIAGRAM RED 30A/2P TO(E) TO(E) IN BRANCH saCK1 L2L1 LOADS LOADS DATE:01.24.2023 f L1NL2 __----------J DESIGN BY:E.T. (E)MAIN ELECTRICAL PANEL A (E)MAIN ELECTRICAL PANEL B CHECKED BY: M.M. EQUIPMENT LEFT EQUIPMENT RIGHT 240/120 V 10,3W 2401120 V 10,3W 6 OF LINE IS(N)NEW I OF LINE IS(E)EXISTING MAIN BUSS:200A MAIN BUSS:200A REVISIONS UNLESS OTHERWISE NOTED. I UNLESS OTHERWISE NOTED. MAX BREAKER SIZE: (200A X 1.2)-200A=40A E-601.00 A B C D E F G H A B C D E F G H SYSTEM SUMMARY MODULES BRANCH#1 BRANCH#2 REF. QTY. MAKE AND MODEL PMAX I PTC I ISC I IMP I VOC I VMP 1 TEMP.COEFF.OFVOC FUSE RATING 1 INVERTERS PER BRANCH / / PMi•15 15 SILFAB PRIME&IL410 HC+ 410W 1387.04W I 11.15A I 1052A I 45.59V I 38.99V I -0.12BVrC(-028%I'C) 20ASMART MAX AC CURRENT 10.64A 10.64A MAX AC OUTPUT POKIER 2,560W 2,56OW ARRAY STC POWER 6,15OW INVERTERS ARRAY PTC POWER 5,806W REF. QTY. MAKE AND MODEL AC GROUND OCPD RATED MAXOUTPUT MAXINPUT MAXINPUT CECWEIGHTED I ENERGY MAX AC CURRENT 2128A VOLTAGE RATING POWER CURRENT CURRENT I VOLTAGE I EFFICIENCY MAX AC POWER 5,120W 11-8 8 APB DS3S 240V FLOATING 30A 64OW 2.66A 2T16A 60V 96.5% DEBATED(CEC)AC POWER 5,12OW CONTRACTOR DISCONNECTS OCPDS SMART SOLAR ENERGY REF. QTY. MAKEAND MODEL RATED CURRENT MAX RATED VOLTAGE REF. OTY. RATED CURRENT MAX VOLTAGE 2 SW1 1 SQUARE D DU222RB OR EQUN. 60A 240VAC CBI-2 2 20A 240VAC CB3 1 30A 240VAC PHONE: 971-645-2487 ASHRAE EXTREME LOW -13.1*C(&4'F),SOURCE:SANDERSON FLD(4724';-123.15') ADDRESS: 10M SW BARNES RD#2W, ASHRAE 2%HIGH 31.1'C(88'F),SOURCE:SANDERSON FLD(47.24':.123.15') PORTLAND,OR 97225 LIC.NO.: 234657 HIC.NO.: ELE.NO.: BILL OF MATERIALS UNAUTIaRIMDUSE OFTHS CATEGORY MAKE MODELNUMBER REF OTY UNIT OTY/UNIT DESCRIPTION DRAWNGSETWTHOUrwt6TTEN PERMISSION FROM CONTRACTOR IS IN MODULE SILFAB PRIME SIL410 HC+ PMI.15 15 PIECES 1 SILFAB PRIME SIL410 HC+410WO 'VIOLATION OF US COPYRIGHTInWS 3 INVERTER APB DS3S 11.8 B PIECES i APSDS3S640WINVERTER AND DkWZOESAAMPROSECOUTION& DISCONNECT SQUARE D DU222RB SWi 1 PIECE i SQUARE D DU222RB,NON FUSED,2-POLE,60A,240VAC OR EQUIVALENT AC COMBINER PANEL GEN-AC-PANEL EP1 1 PIECE i AC SUBPANEL NEW PV SYSTEM:6.150 kWp WIRING GEN.IO-AWG-THWN-2-CU-RD WRI3 110 FEET 1 10 AWG THWN-2,COPPER,REDLINE 1) WIRING GENAC0 AW13,THNN.2-CU-BLK WRI-3 110 FEET 1 10 AWG THNM•2,COPPER,BLACK(LINE 2) P I TT WIRING GEN-ID-AWG-THWN-2-CU-WH WR23 20 FEET 1 10 AM THNN-2,COPPER,WHITE(NEUTRAL) WIRING GEN-10-AWG-THWN-2-CU-GR WR73 65 FEET 1 10 AWG THWN-2,COPPER,GREEN(GROUND)WI RESIDENCE REWAY GEN4 VC•40.0.75"DIA WWI-3 FEET 1 PVC-40 CONDUIT,0.75"DIA OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC CBI 1 PIECE 1 CIRCUIT BREAKER 20A,240VAC OCPD GENERIC MANUFACTURER GEN-CB-20A•240VAC CB2 1 PIECE 1 CIRCUIT BREAKER,20A,240VAC 23430 US-101, OCPD GENERIC MANUFACTURER GEN-CMA-240VAC CB3 1 PIECE 1 CIRCUIT BREAKER,30A,240VAC HOODSPORT,WA 98584 TRANSITION BOX GENERIC MANUFACTURER GEN-AWB-TB4 4X JBi 1 PIECE 1 TRANSITION/PASS-THROUGH BOX,WITH 4 TERMINAL BLOCKS APN:422144100160 4 ENGINEER OF RECORD 5 PAPER SIZE:Irx 1r(ANSI B) DESIGN TABLES DATE:0124.21123 DESIGN BY:E.T. CHECKEDBY: M.M. 6 REVISIONS E-602,00 A B C D E F G H A B C D E F G H !CAUTION! 1 POWER TO THIS BUILDING IS ALSO SUPPLIED SMAR FROM ROOF MOUNTED SOLAR ARRAYS WITHENERGY LABELING NOTES SAFETY DISCONNECTS AS SHOWN: 1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE, BACK PVARRAY CONTRACTOR INTERNATIONAL FIRE CODE 605.11.OSHA STANDARD 1910.145,ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING PVARRAY 0 JURISDICTION. SMART SOLAR ENERGY 2 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. PHONE: 971d05 2487 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3IB-AND PERMANENTLY AFFIXED, 1.5 ALERTING WORDS TO BE COLOR CODED.'DANGER'WILL HAVE RED ADDRESS: 1D940 SW BARNES RD#2W, BACKGROUND;WARNING'WILL HAVE ORANGE BACKGROUND;-CAUTION-WILL HAVE PORTLAND,OR 97225 YELLOW BACKGROUND.[ANSI Z5351 MAIN DISTRIBUTION INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED UTIUTY DISCONNECT ELECTRICAL SHOCK HAZARDRAPID SHUTDOWN PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED UC.NO.: 234657 SWITC WEST SIDE OF THE HOUSE HIC,NO.: TERMINALS ON THE LINE AND H FOR ELE.NO.: DIRECTORY METERNAIN UNAUTHORIZED USE OF THIS LOAD SIDES MAY BE ENERGIZED SOLAR PV SYSTEM DRANNCSET WITHOUTMITTEN IN THE OPEN POSITION PERMANENT PLAQUE DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING PERNIss ION FROM CONTRACTOR Is INu Von O ON OF U.S.COPYRIGHT uws LABEL! LABELS MEANS IF NOT IN THE SAME LOCATION(5314-X i 1IB"). UTILITY POLE ANovAu 9E SUBJECT CT TOTo cant P 3 AT EACH DISCONNECTING MEANSFOR AT RAPID SHUTDOWN DISCONNECT SWTTCH(5 114-X 21. [NEC 690.56(B)I Z DA.GES AND PROSECUTIONS. )(3)I. PHOTOVOLTAIC EQUIPMENT IT X 41. (NEC 693—C WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER,A (NEC W0.13). DIRECTORY IN ACCORDANCE WITH 705.10SHALL BE PROVIDED AT EACH PV NEW PV SYSTEM:6.150 kW SYSTEM DISCONNECTING MEANS. ; FRONT PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN O O PITT BATHROOMS POWER SOURCE (NEC MA(D),(E)] OUTPUT CONNECTION SOLAR PV SYSTE DO NOT RELOCATE THIS EQUIPPED WITH RESIDENCE PHOTOVOLTAIC POWER SOURCE 2 OVERCURRENT DEVICE PID 23430 US-101, AT POINT INTERCONNECTION AT OINT OF INTERCON TO PV ARRAY HOODSPORT,WA 98584 OVERCURRENT DEVICE(2-X 41. LABEL 9 (NEC 705.12(B)(2)(3)[B)I. AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER WIRING E7ER/MAIN APN:422144100160 4 METHODS;SPACED AT MAXIMUM 10 FT SECTION OR WHERE ENGINEER OF RECORD AC DISCONNECT , SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS, OR FLOORS(5 34-X 1 MB-). PHOTOVOLTAIC SYSTEINEC690.31(D)(2)] AC LOAD CENTER POWER SOURCE TURN RAPID SHUTDOWN SWITCH TO AC DISCONNECT RATED'RENT THE'OFF'POSITION TO SHUT DOWN e PV SYSTEM AND REDUCE SHOCK WEST NOMINAL, OPERATING ,a HAZARD IN ARRAY WALL AC VOLTAGE k AA LABEL 3 LABELS MULTIPLE SOURCES OF POWER AT POINT OF INTERCONNECTION,MARKED AT RAPID SHUTDOWN SYSTEM I D (3 31C X 51141.INEC 690.56(CH1)(A)I. AT DISCONNECTING MEANS(4'%3'. LABEL 10 I UTILITY POLE [NEC 69D 541 AT UTILITY METER(5 314-X 1 11n (NEC�056(B)] 5 B B DUAL POWER SUPPLY TO(E)MEP I UTILITY PAPER SIZE:11'v 17'(ANSI S) SOURCES:UTILITY GRID SOUP ELLOmC ONSIDE) B , ELECTRIC SYSTEM CIR��CNFEU� GRADE PLACARDS LABEL/ LABEL7 LABELS AT EACH AC DISCONNECTING MEANS AT POINT OF INTERCONNECTION AT POINT OF INTERCONNECTION DATE:01.24.2023 (4-X 69 (2 3/4-X 1 S'B-). I?X 1.). (NEC 0.13(B)]. [NEC 705.12(B)(3)] INEC 705.12(8)(3)] DESIGN BY:E.T. PMENT ELEVATION CHECKEDBY: M.M. S IE4E REVISIONS E E-603.00 A B C D E F G H A B C D E F G H zD GENERAL NOTES 1 27 .50 1. FlELDVERIFYALLMEASUREMENTSSMART 2. ITEMS BELOW MAY NOT BE ON THIS PAGE 23 24 25 r L 11 �, I i 13 14 15 18 2212CONTRACTOR 3 Q SHEET KEYNOTES SMART SOLAR ENERGY F--2 1. ROOF MATERIAL:ASPHALT SHINGLE PHONE: 971-645.2487 RACKING DETAIL (LONGITUDINAL) 2. ROOF STRUCTURE:TRUSS ADDRESS: 10940 SIN BARNES RD#250, D� 3. AIIACHM ENT TYPE:SUNMODONANOMOUNT NOT TO SCALE 4. MODULE MANUFACTURER:SILFAB PRIME PORTLAND,OR97225 5. MODULE MODEL:SIL410 HC+ 6. MODULE LENGTH:75.3" UC.NO.: B497 �nl 7. MODULE WIDTH:40.8" HIC.NO.! RACKING DETAIL TRANSVERSE B. SEE SHE TA-103:47LBS. ELE.NO.: D 1 9. SEE SHEET A-103 FOR DIMENSION(S) uNAurHORrzEouseoF THIS 10. MIN.FIRE OFFSET:18"FROM RIDGE,36"FROM EDGE DRAWNG SET NTHOurwRITTEN NOT TO SCALE 11. TRUSS SPACING:24 IN.O.C. PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS 12. TRUSS SIZE:2X9 IN.NOMINAL ANO WILL BE SUBJECT TO VIAL 3 t0 O 13. LAG BOLT DIAMETER:3181N. QAMAGES ANO PROSECUTIONS. 14. LAG BOLT EMBEDMENT:41N. NEW PV SYSTEM:6.150 kWp 15. TOTAL#OF ATTACHMENTS:40. 16. TOTAL AREA:320.03 SQ.FT. m 17. TOTAL WEIGHT:792.69 LBS. PITT 18. WEIGHT PER ATTACHMENT:19.82 LBS. 19. DISTRIBUTED LOAD:2.48PSF RESIDENCE 20. MAX.HORIZONTAL STANDOFF:48. 21. MAX.VERTICAL STANDOFF:IN ACCORDANCE WITH 23430 US101, © 2, MODULE MANUFACTURERS INSTRUCTIONS. HOODSPORT,WA 98584 22. STANDOFF STAGGERING:YES 23. RAIL MANUFACTURER(OR EQUIV.):SUNMODO APN:422144100160 4 ------ ------- ------ ------- ------ 24. RAIL MODEL(OR EQUIVALENT):SMR100 ENGINEER OF RECORD 25. RAIL WEIGHT:0.4126 PLF 26. MAX.TRUSS SPAN:WA FT. 27. MODULE CLEARANCE:3IN.MIN.,6IN.MAX. (� RACKING DETAIL (TOP) V J NOT TO SCALE 5 PAM SM 1 r%lr m e) ASSEMBLY DETAILS DATE:01.24.2023 NN DESIGN BY:E.T. CHECKED BY: M.M. 6 [�DE�TLAIL TRANSVERSE [ 1�DE�TT�IL (LONGITUDINAL) REVISIONS S-501,00 A B C D E F G H A B C D E F GENERGY N SMART euaeul.foecnlurloNf ao „..,m.m er.o ar rrom..� 3eles wx. CONTRACTOR SILFAB PRIME 51 L FA B• �f11 ea�N« ��' ss.�.�.e�e.,.r+.,r I's<; SMART SOLAR ENERGY SOLAR" .rx m,Kam.o.,f.nocr 2 n-a,n Nc. meramf o �.� ore,...a w,P .m•�o PHONE: 971-645-2487 ADDRESS: su^,�,..,„ram,r�,..4e'�"'m�;u�'n,^.+I„M.,.,rel.".,<,rwr.r ,,K, ,.r,�"`,""'a.s..MF•.•ra.m•lwr 10940SW BARNES RD#tSO, NFG:NMIrAt nroronwlcawAawexrf �.flenrc - PORTLAND,OR 97225 MM,ne.eMA. xx.nf ea.xy .na,a.ax„ ,m.m>,.,.,mae l.wru,sq• r.a,wersmn'romro.e 'uemrxr-rwwrl':emrn.«„'we SIC.NO.: 234657 ss r3anrela-s�momnx 3x Ral,en,.vmorw vAPc HIC.NO,: ceee iwwar..x.lssmm ,m - ESE.NO.: m'xen vammuun...,emoerM, e.rem,rzrM, UNAUTIORQED USE OF TMS Glexs armmehca..cwrine ^ pUW,AM SET WTHOUT WRITTEN Cae4,aM w^namnrnM(o�m1aM4^n ms-MI mm mm.„c+l,v^srawi� IILSW6'..wc+I-1I.- PERMISSION FROM CONTRACTOR IS IN exA,nen xiene.rae�u ,uvmo,nvM1.M�+aM rn,<ana«e.mm'1'.rm e'rei«v�.mm. "ATION OF U.S.COPYRIOM LAWS li.,w,,,e4+ hx S:AeN DAMAGES BE AND PRE TO CMS 3 rr.^e M^ei[M Awmi^em lel.,x) w c DAMAGES AND PROSECUTIONS. arw!„oa 7e� - .ry o ti«.,^e.on ee 3o rer,a.=u,r u[ Ar,Ne oY .. 6x796ie6WAR[xr^Te.IE s-,_m Mo... p,n NEW PV SYSTEM:6.150 kWp T-1.1.1 ,. — PITT KK, NPm, R �sxe,w a sxr RESIDENCE .r C[RTIR[ATIONf fNIMINe f.[Cf 2017Fe1.A11211:1617ReI.N1111-2011ee.1.N16113R.x2011 M�,.Iwmm+l 23430US-101, Paa a«r E nA'E<'s��s aI,xla CcA enpe+iioencla,iiEiCxis],w 1Am'nosMl,a CuomoENlml EIe :O. ,CFC U 4Ny V. vaIM•+Mr InMan nd3orcnmm�.l HOODSPORT,WA 985 84 ITI',N I — APN:42214100160 d rku�.em...�r++v�r>^,�,�..,.�e . ,^N,w�.^•m..^,•M�^�.-., ENGINEER OF RECORD my Ma mm ,x.,•L�O,mml s,xl,�oaiml ,z,•(aoTmml — RELIABLE ENERGY. SILFAB SOLAR INC. DIRECT FROM THE SOURCE os• 9Hsn{A:nfW�fexrfMfA I,2mmi .I xm.sss nn — 'nlop,illabWacmm Designed to outperform. 11 eolee RON 5 Dependable,durable,high-performance �—'� h r I —1-DWe9fxll uLl PAPER SIZE 11".17(ANSI B) H16solar panels engineered for North "°L"" '"('�"'L '�o� -e 6.s9aED American homeowners. f o �6Coursa%""rr RESOURCE DOCUMENT SILFABSOLAR.COM ooe• s�.,s �' r.'enc e.6.6�sT DATE:01.2d 2023 'aLN.�' pramege A3an RBI R+ ^' °"' »4�•+�•*-+ DESIGN BY:E.T. L E Fraunhofer - CHECKED BY: M.M. �A-A UE3 a �,. .. ,.v ....,.-,.......,. ..., . - -za•IRNmmI e-In3Onm), REVISIONS 6 R-001,00 A B C D E F G H A BasCis D as E is F se G as O-4 APsystems Leading the Industry in ' • A L T E N E R G Y P O WE R Solar Microinverter Technology Model DS3-S DS3-L DS3 SMART Region USA (7anacf:r Input Data(DC) a ENERGY Recommended PV Module Power(STC)Range 250WP-480Wp+ 265WP-570Wp+ 300Wp-66000p+ . Peak Power Tracking Voltage': 28V-45V Series Operating Voltage Range 26V-60V CONTRACTOR The most powerful Maximum Input Voltage 60V Maximum Input Current 16A x 2 18A x 2 20A x 2 SMART SOLAR ENERGY Micreinverter Maximum input short circuit current 20A per input 22.SA per input 25A Per Input 2 One microinverle,cormects to •Solar modules Output Data(AC) PHONE: 971-645-2487 Max output power reaching- a . 768VA or Maximum Continuous Output Power 640VA 768VA 880VA ADDRESS: 10940 SW BARNES RD#250, Nominal Output Voltage/Range"' 240V/211V-264V PORTLAND,OR 97225 Two independent input Channel,(MPPT) Nominal Output Current 2.66A 3.2A 37A CA Rule 21[UL 1741 SB)compliant Maximum Output Fault Current(ac)And Duration 5.691Apk.26.75ms of duration:3.307Arms NEC 2020 690.12 Nominal Output Frequency/Ranger" 60Hz/58.8Hz-61.2Hz(HECO:57Hz-63Hz) Encrypted Wireless ZigBee Communication IJC.Ni 234657 Power Factor(Default/Adjustable) 0.99/0.8leading.-O.8 lagging HIC.NO.: Phase Monitored and Phase Balanced Maximum Units per 30A Branch"' 9 7 6 ELE.NO.: Maximum Units per 20A Branch"' 6 5 4 UNAUtHDRIZED USE OF THIS AC Bus Cable 1OAWG/12AWG DRAWING SETVATHOUT ARITTEN PERMISSION FROM CONTRACTOR IS IN Efficiency VIOLATION OF U.S.COPYRIGHT LAWS 3 Peak Efficiency 97.3% DAMAGES T TO BE CMSAMAGESWILL AND FRD DNS. P CEC Efficiency 97% PRODUCT FEATURES Nominal MPPT Efficiency 99.5% NEW PV SYSTEM:6.150 kWp Night Power Consumption 20m W P I TT APsystems'3i°generation of dual-module microinverters,the DS3 product family represents the culmination of years of power conversion expertise and Innovation in high-efficiency,high-density power conversion to maximize the peak Mechanical Data performance of today-s high-capacity PV modules. Operating Ambient Temperature Range"' -40-F to+149"F(-40°C to+65"C) The DS3 series reaches unprecedented levels of power output.It features 2 input channels,each with independent MPPT, Storage Temperature Range -40"F to+185-F(-40'C to+85'C) R E S I D E NC E and encrypted wireless ZigBee communication.An innovative and compact design makes the product lighter while Dimensions(W x H x D) 10.3"x 8.6"x 1.6" 10.3"•8.6"x 1.7" maximizing power production,and silicone-encapsulated components reduce stress on electronics,facilitate thermal (263mm x 218mm x 412mm) (263mm x 27 23430 US-101, dissipation,and enhance weatherproofing.Reliability is significantly increased thanks to 20%fewer components than x 42.Smm) previous generations.A 24/7 energy access through apps or web based portal facilitate remote diagnosis and maintenance. Weight 5.bilM.7k9) 4-S2(3.lkg) HOODS PORT,WA96564 The DS3 series is grid-interactive and fully compliant with CA Rule 21 requirements.With its unparalleled performance, DC Connector Type S[auN MC4 PV-A coon-28ADSP4-52 APN:422144100160 efficiency of 97.3%,and increased reliability.the APsystems DS3 series is a gamechanger for residential and commercial Cooling Natural Convection-No Fans 4 Enclosure Environmental Rating Type 6 ENGINEER OF RECORD Solar. Features Communication(Inverter To ECU)"I Encrypted ZigBee WIRING SCHEMATIC Isolation Design High Frequency Transformers,Galvanically Isolated Energy Management Energy Management Analysis(EMA)system Warranty` 10 Years Standard;25 Years Optional Compliance Safety and EMC Compliance UL1741:CSA C222 No.107.1-16:UL77415A;UL1741SB: It IEEE1547;Rule 21;SRD-V2.0;FCC Part15;ICES-003; NEC 2074&NEC2017&NEC2020 section 690.11 DC Arc-Fault ftcircuit Protection;NEC2014&NEC20178,NEC2020 Section 690.12 Rapid Shutdown of PV systems on Buildings e-a5vrargeMmeio✓ve.-srs All Rxi-PoeservM r!vI(ovaiuesmeen E<ei?v�i'r/ve v9e Mdeires vp9rettC wMm FCV $peolrcar/mf iVarY['rrocVYnee wieCuraWk'I AYYe A011 a`e iT>rw��y)wlrryc,gw�rrA+c i ��"om,raro u...rwrne�lnr+ ,rs„y menxvsrrecenr up6xe louts ar D:vsv.A?snfems..mm PAPt319�:71'x 1T lAl151 B) 5 w_m..�r..,r o,.0 .�„.,,.,,�:1� "„ma, m..o�.4,le� w,.rr wm.+.r aww wxa-w...."nm�.,,Ww wm r„vwnw� RESOURCE DOCUMENT f\/ wWdt un«.mov'swrw+b Ta6:, :uwn°asmmuaT .nrarno < S�e r.Pulnments I.r(ishibaeb APariteal eN' `" 4'" �" '°'ices(M DATE:01,24.2023 ex 8627 N.Mopac Expy,Suite 150.Austin,Tx 78759 LW xwrxnw wlm tn.cu WMk apsystems.com DESIGN BY:E.T. 2023/06/25 Rev1.9 CHECKED BY: M.M. REVISIONS 6 R-002.00 A B C D E F G - A B C re D re E re F re G re H SMART SUNM*avp'h� ' SAAR100 Rail SMR100 Rail CONTRACTOR SMART SOLAR ENERGY 2 PHONE: 971-645.2487 ADDRESS: 10940 SW BARNES RD#250, °i PORTLAND,OR 97225 LIC.NO.: 234657 HIC.NO.: ELE.NO.: TNAUMDRIZED USE OF TNIS ORAN1NG SET WIT'WT WRITTEN PERMISSION FROM CONTRACTOR IS IN NOTATION OC U.S.COPYRIGIR LAWS 3 Medsgnical Properties Section Properties D�AMAWGES um PPRROSEnmau. Momew"6005.T5 Ak-inom Ss:0.196 in'(3.21 on') Weight 0.4126lb✓N 10.614 kg/m) Sy:0.146 irP(2.39 on3) NEW PV SYSTEM:6.150 kWp Uhimae Tensile S"wVh:37.7 ksi(260 MP,) Arso Ot-region):0.352 in'(2.27 cm') SMR200 Rail Veld Strength:34.8 ksl(240 MPa) P ITT SMR200 Rail RESIDENCE 23430 US-101, i HOODSPORT,WA 98584 APN:422144100160 4 ENGINEER OF RECORD :a 5 Part Number--- Description A1od—ioe1 Properties Section Properties PAPER SIZE'.11'x 17'(ANSI B) A20422-168-11K SMR100 Rail,Block Anodized,168' Moledol:6005_T5 Alambwm S.:0.223 im313.74 cm3) Weight:0.453 It(0.626 kg/m) Sy:0.189 Ins 13.10 cros) RESOURCE DOCUMENT Ul inhote Tensile SbengM:37.7 ksi(260 MPo) Am(%-mctionl:0.388 in'(1.22 on') A20431-168-BK SMR200 Roil,Black Anodized,168' Yield S-no:34.8 lei(240 MPa) DATE:01.24.2023 A20440.BKI SMR100 Rail End Cap,Block DESIGN A20440-81(2 SMR200 Roil End Cap,Block owns voor CHECKED BY: M.M. Oeneaiow eba.n an eh,iaa lwb�n,m.e dpihen hubranhM1wN..enoa mew REVISIONS 6 R-0O3.00 A B C D E F G H A B C D E F E 1 SMART 3--- ° SUNMDO ' [S�Y&NM f D • — ENERGY - .ING by . ,� LEADING by DESIGN LEA5 levels of protection against CONTRACTOR • water penetration SMART SOLAR ENERGY � Open L-Foot for fast 4 Deck Screws for Deck Mount or 2 rail attachment 1 Lag Bolt for Rafter Mount PHONE: 971-645-2487 ;Yti.;. ADDRESS: 10940 SW BARNES RD#250, FASTEST360-degree positioning, PORTLAND,OR 97225 serrated surface on both sides for raly/ il mounting UC.NO.: 234657 HIC.NO.: ATTACHMENT ELE,NO.: UNAUhaRQED USE OF THIS Aesthetically pleasing TTEN v�MissoFRan�N rt�ncroRisiN unibody aluminum cast VIDuTIONOFU.S.COPrRiGNruws construction OAMASEs um PPRROSECUTONS. NEW PV SYSTEM:6.150 kWp Rafter • ' PITT Integrated Ultra Soft RESIDENCE Weather Resistant Alignment markers gasket 23430 US-101, The NanoMount®Advantage enable easy installation HOODSPORT,WA 98584 Damaging •• APN:422144100160 4 to be one of a solarinstallers' ✓ The fastest roof attachment in ENGINEER OF RECORD solar. worst ✓ Versatile mounting options Now, • affordable including direct-to-decking. solution is . . • ✓ Eliminates the need to lift shinglesSunM • •'• patented • • and prevents damage to shingles. Application Residential roof coverings,commercial single-ply roof membranes mounting innovation. ✓ High-Velocity Hurricane Zone Material High grade aluminum,304 stainless steel hardware 5 The mount eliminates the Approved - Passed TAS 100(a) Finish Black powder coating PAPER SIZE 11 n'(ANSIB) Wind-Driven Rain Test. need for lifting shingles Roof Attachment Rafter and decking RESOURCE DOCUMENT • • dramatically reuces ✓ All materials are compatible with asphalt shingles and Structural integrity IBC and IRC Compliant DATE:01.24.2023 installation I the single-ply roof membranes. warranty 25 years DESIGN BY:E.T. CHECKED BY: M.M. SunModo,Corp.Vancouver,WA.,USA•www.sunmodo.com•360.844.0048•info@sunmodo.com REVISIONS 6 R-004,00 A B C D E F G H A BIN C IN D NE E IN F NE G IN H SMART tLFRMCAt snCiFiCATM}NG 410 ENERGY e" mN Np .,ewm <,roiu5<nww! }asr w.3. •;••• """"m°`"`"" CONTRACTOR N• °pen nrtua rokaxe N«I .3.16 SILFAB PRIME SILFAB mn ; " "..:,: r :P.tR +rs SMART SOLAR ENERGY N,. w? °m•,° PHONE: 971-645-2487 sra.m:..�re,x xw..x.:.m. ..rah.��.'""x.rri,.w..r,..,«,.�..., ,.:,�""�"n,r+�ww'•ro a, ADDRESS: 10940 SW BARNES RD#250, PORTLAND,OR 97225 ,Rr NEcwaisunieRliW - . .?yf!!"n _.p. ui<"eig"t n.A1x✓IIN eTBs zO.elln m-"m"..wel»,.en�wmr re<w.eis,mnrmmlwe u.cwma�paa?M,:.aN}Er,",,,n.e LIC.NO.: 234657 "ea.wn,nm...,. sem Pe x.ml• .wxsit mp" aB,m }sslwrae�.vmpn°ntc ssN,nau:.s:ew,.,ptpc HIC.NO.: ELE.NO.: m NN�m"+mini«e.«mPNM. °.t3eh Mgn rmmm�ianc<u:nw"p, UNAUi ORIZEDUSEOFTHIS G.sss mi-:elN�eeewenl :rerl«rsrccaeny DRAWING SET WITHOUT WRITTEN eaue+uMsmm<w+�,x.+r"im�eN.rwn nwwae ,S omm,.iT mm,uU r.pm Suudi 11 ..n inlvAwe:.x[.I:"m s,euou' PERMISSION FROM CONTRACTOR IS IN NMne�..am,,+"p,eu NAaxn"a"d w rex,,.«".mei°-i<m.eieMcrM°tn. 1ACIATION OF U.S.COPYRIGHT LAWS aesbNen °,w,,,K„R T'LLxyM1ex AND VSLL BE SUBJECT TO CML 3 oeum 1N�l x } DAMAGES AND PROSECUTIONS. ] °c—els„ «. NEW PV SYSTEM:5.150 kWp TEMPERATURE RATINGS : WARRANTIES PITT r OCi Iza1uC'Cpelnicl"ni>ma. 1°Y G,C i911>.eMIS b y RESIDENCE CERTIFICATIONS SNIPPING SPECS e 1.16,3,,11 iT Ill 1.°L11 o.1:3 7 F I0 xe"„p,paem a.,cx:". 23430 US-101, p� ;(Ssma Ea"E 633°}w,Gle3,ilcs,tx}sp,.Ee3.ilc m39,san NNrew,°,iwe,:lcnnc3°u HOODSPORT,WA 98584 lnmmwiac«mxero,crc uxt�,u, rxNr,r.,r"Kx n«mrcxx«nix "A"'°"" APN:422144100160 4 _ .Nw"n.a,MVM �"x ixw x .ire:w wMw m�,,ee�m� a.i«x wme«.e",mom ENGINEER OF RECORD „x .n e p•" E,mx.em....eP.�,«"�,:..m...,<.�i.x<r-emn.�a..,,.,,e.•,,,."mm,.,�..�. 1,,, _ ._ TGr Im•,.nl 12A'(V I_ 5121130 1 _ 121'13Dtmm1 1 ' SIVAS SOLAR INC. RELIABLE ENERGY. rMl•ra+l • BW C°nN}tE Ave DIRECT FROM THE SOURCE. 05• BxEt,NtmWAeanSusA —— inroca+urelNdx<pm Designed to outperform. r3R�i' 1,....1= 5 Dependable,durable,high-performance _ PAPaIs12E n•xtr ullq III -q_�mL o�o�r � Bu;ingron WA 95}13115/� solar panels engineered for North American homeowners. - o ; RESOURCE DOCUMENT Asswy ON I ST 3Y3 I.— T. '9Ps.Iss.:sot SILFAB$O LA R.COM 1°s�mml _ — 113Ja5orN.nl r.9M b950}eT DATE:01.24 2023 '' OeOM LergN 1! 91M -IN tleMK..lprx.+w DESIGN CE � Q �. I EC M Fraunhofer c H u E3 E3 zao, 1. — M.M. • . ,. ,...,�,.... ..- " REVISIONS 6 R-001.00 A B C D E F G H A xx B ex C ex D ax E al F al G at 0Microinverter Series .4 APsystems Leading the Industry in e 1 A L T E N E R G Y P O W E R Solar Microinverter Technology Model DS3-S DS3-L DS3 SMART Region USA Canada Input Data(DC) ENERGY Recommended PV Module Power(STC)Range 25CWp-480Wp+ 265WP-570Wp+ 300Wp-i . Peak Power Tracking Voltage(', 28V-45V Operating Voltage Range 26V-60V CONTRACTOR The most powerful Maximum Input Voltage 60V Maximum Input Current 16A x 2 18A x 2 20A x 2 SMART SOLAR ENERGY Micreinverter Maximum input short circuit current 20A per input 22.5A per input 25A per input 2 e ne microinvere,Connects to •solar modules Output Data(AC) PHONE; 971E45-2487 Max output power reaching a . Maximum Continuous Output Power 640VA 768VA 880VA ADDRESS: 10940 SW BARNES RD#250, Nominal Output Voltage/Range(" 240V/211V-264V PORTLAND,OR 97225 Two independent input channels(MPPT) Nominal Output Current 2.66A 3.2A 37A Maximum Output Fault Current(aU And Duration 5.691Apk,26.75ms of duration;3.307Arms 2020 690.12 Rapid Shutdown Compliant Nominal Output Frequency/RangeR1 60Hz/58.8Hz-61.2Hz(HEC0:57Hz•63Hz) It SIC.NO.: 234657 BalancedEncrypted Wireless ZigBee Communication Phase Monitored and Ph... Power Factor(Default/Atljustable) 0.99/0.8 leading...0.8 tagging HIC.NO.: Maximum Units per 30A Branch"' 9 7 6 ELE.NO.; Maximum Units per 20A Branch°' 6 5 4 UNAUngRIZED USE OF THIS AC Bus Cable IOAWG/12AW G DRAVANG SET YATHOUr WRITTEN PERMISSION FROM CONTRACTOR IS IN Efficiency VIOLATION OF U.S.COPYRIGHT LAWS 3 Peak Efficiency 97.3% DAMAGES DAMAGES AND SECU ML AND PRECTTO10NS PRODUCT FEATURES CEC Efficiency 97% Nominal MPPT Efficiency 99.5% NEW PV SYSTEM:6.150 kWp Night Power Consumption 20mW P ITT APsystems'3'^generation of dual-module microinverters,the DS3 product family represents the culmination of years of power conversion expertise and innovation in high-efficiency,high-density power conversion to maximize the peak Mechanical Data performance of today's high-capacity PV modules. Operating Ambient Temperature Range" -40-F to+149'F(-40'C to+65'C) The DS3 series reaches unprecedented levels of power output.It features 2 input channels,each with independent MPPT, Storage Temperature Range -40`F to+185-F(-40-C to+85°C) R ES I D E N C E and encrypted wireless ZigBee communication.An innovative and compact design makes the product lighter while Dimensions(W x H x D) 10.3"x 8.6"x 1.6" 10.3-x 8.6"x 1.7' mm maximizing power production,and silicone-encapsulated components reduce stress on electronics.facilitate theal (263mm x 218mm x 41.2mm) (263mm x 21) rm x 42.Smm 23430 US-101, dissipation,and enhance weatherproofing.Reliability is significantly increased thanks to 20%fewer components than previous generations.A 24/7 energy access through apps or web based portal facilitate remote diagnosis and maintenance. Weight 5.71bs(2.7kg) 6.81bs(3.lkg) HOODSPORT,WA 98584 DC Connector Type Staubli MC4 PV-ADSP4-S2&ADSP4-S2 APN:422144100160 The DS3 series 3 DS3 and fully compliant with Rule requirements.With its unparalleled performance, Cooling Natural Convection-No Fans 4 efficiency of 97.3%,and increased reliability,the APsystems DS3 series is a gamechanger for residential and commercial Enclosure Environmental Rating Type 6 ENGINEER OF RECORD Solar. Features Communication(inverter To ECU)°' Encrypted ZigBee WIRING SCHEMATIC Isolation Design High Frequency Transformers,Galvanically Isolated Energy Management Energy Management Analysts(EMA)system Wanani 10 Years Standard:25 Years Optional Compliance Safety and EMC Compliance UL1741:CSA C22.2 No.107.1.16;UL1741SA:UL17415B: IEEEIS47;Rule 21;SRD-V2.0;FCC Pill ICES-003; NEC2014&NEC2017&NEC2020 Section 69031 DC Arc-Fault circuit Protection;NEC2014&NEC2017&NEC2020 Secton 690.12 Rapid Shutdown of PV systems on Buildings texhrovNvesmnr Cervneremonp,v nSJmmbswxha SA-a5vrwge1wmWomerters is All Rights Resw W corv,ectM ro en ECUnm'lJtreSvrenge Mpevrces upfl°<'<C"'Mm ECU. SpecilKafiOK s✓a/eCrb o"Ani wiauur natiea/1__yJv a-e mov__1`ouare fovrwor web:�so.Ar:rrcros.n,� PAPER SIff:t1'x 17'(ANSIS) rn i,ti�.nlm.,„v.wh+romwwoe.v,w.�,,,ae.wo-.Lsrcr«ru7a�enrArc,:eiv.wr «>AK` °b° 2ag M� ro„=a roaMe w.r� �ww� RESOURCE DOCUMENT ign^ n (arm nease eh�fM1awanaMA 6CxmsmKrrevrtwsr,MrobmwxarW rvafna EMA e req,»Meets the 5tatxl v.a erd rl I \i \v r rom+war ryr savvudew n�snM1w�an. gSremerts lGr Dis[ributM V APsystems �e nere ErRem„K.eSauTAu ( DATE:01.24.2023 an i wkh[M 8627 N.Mopac Espy,Suite 150,Austin,TX 78759 C IB ListM Mark tlen[ifreO CSA � apsystems.com — DESIGN BY:E.T. 2023/06/25 Rev1.9 CHECKED BY: M.M. REVISIONS 6 R-002,00 A B C D E F G H A Ae C er D m E m F m G H SMART SUNM*::3' . . SWIM Rail SMR1OO Rail CONTRACTOR SMART SOLAR ENERGY 2 PHONE: 971-452487 ADDRESS: 10M SIN BARNES RD#250, 9� PORTLAND,OR 97225 LIC.NO.: 234657 HIC.NO.: ELE.NO,: UK4UTHDRRED USE OF THIS DRAWING SET WTHOUT WRITTEN de PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAW5 AND WILL BE SUBJECT TO CML 3 Meehankal Properties Section ProperNee DAMAGES AND PROSECUTIONS, M°lerw1:6005-T5 Aluminum Sz:0.196in'(3.21cmr1 Welehc 0.4126 11,0 10.61 A kg/m) Sy:0.146 in'(2.39 crr) NEW PV SYSTEM:6.150 kWP Uhimule Temik Str.Vh:37.7 kd(260 MPa) A—(X-redion):0.352 inr(2.27—1)SMR200 Rail P ITT YwW S'nm,0:34.8 kel(240 MPa) SMR200 Rail RESIDENCE 23430 US-101, HOODSPORT,WA 98584 APN:422144100160 4 ENGINEER OF RECORD 144to. .M-4 5 Port Number Dwaiption meth ical Propwtere Section Propewti., PAPER SIZE I1'x 1T IANSI B) A20422.168.BK SMR100 Rail,Block Anodized,168' Mormfal:6005-T5 AMmieum S:0.223 ia313.74 cmr) WeiyM:0.4531bVh(0.626 katn) S,:0.189 inr 13.10 rm21 RESOURCE DOCUMENT a—.—. _.. Uhir Tenvk St enplh:37.7 kel(260 MPc) Area(X-section):0.388 in7(1.22 anr) A20431-168-BK SMR200 Roil,Block Anodized,168' Yield S-91h:34.8 k11(240 AAPz) DATE:01.24.2023 A20440.BKI SMRI00 Roil End Cap,Block DESIGN I E.T. A20440.BK2 SMR200 Rail End Cop,Black mom-voot CHECKED BY: M.M. aFeneere e,rvm an Y,tli-laM�eM�e�l 0.g1k en uAl.p a shop.11,en netl- RENSIONS 6 R-003r00 A B C D E F G reH A B C D E F G H SMART NERGY -- Key Features of NanoMount* LSUNMQDO� • M. . - - LEADING by DESIGN 5 levels of protection against CONTRACTOR . water penetration SMART SOLAR ENERGY � �``'�,_ Open L-Foot for fast 4 Deck Screws for Deck Mount or 2 "�' rail attachment 1 Log Bolt for Rafter Mount PHONE: 971-645-2487 ADDRESS: 1D940 SW BARNES RD#250, FASTEST 360-degree positioning, serrated surface on both IY/ PORTLAND,OR97225 sides for rail mounting LIC.NO.: 234657 ATTACHMENT HIC.NO.: ELE.NO.: UNAUTHORIZED USE OF THIS Aesthetically pleasing DRAMNG SETWt Hou wR EN NanoMountO" y p g PERMISSION FROMLOMRACTOR IS IN unibody aluminum cast NOATION OF U.S.COPYRIGHT LAWS 3 construction ANOW UL BE SULECT TO CIVIL DAMAGES AND PROSECUPONS. NEW PV SYSTEM:6.150 kWp • • ' PITT Integrated Ultra Soft RESIDENCE Weather Resistant Alignment markers gasket 23430 US-101, The NonoMount®Advantage enable easy installation HOODSPORT,WA 98584 Damaging •• shinglesuse APN:422144100160 to be one of a solar installers' ✓ The fastest roof attachment in ENGINEER OF RECORD worst • • solar. ✓ Versatile mounting options Now, .•. - including direct-to-decking. solution ' • • ✓ Eliminates the need to lift shingles Technical Data SunMo•• patented • • and prevents damage to shingles. Application Residential roof coverings,commercial single-ply roof membranes mounting innovation. ✓ High-Velocity Hurricane Zone Material High grade aluminum,304 stainless steel hardware 5 Approved - Passed TAS 100 (a) PAPER SIM11',1-(ANSI B) _ mounteliminates • _ _ Finish Black powder coating need • • shingles Wind-Driven Rain Test. Roof Attachment Rafter and decking RESOURCE DOCUMENT • • dramatically re ✓ All materials are compatible Structural integrity IBC and IRC Compliant DATE:01.24.2023 the installation - with asphalt shingles and single-ply roof membranes. Warranty 25 years DESIGN BY:E.T. CHECKED BY: M.M. $unModo,Corp.Vancouver,WA.,USA•www.sunmodo.com•360.844.0048•info@sunmodo.com REVISIONS 6 A B C D E f G H R-004,00