Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD94-1219 Mitigation Measures for Spray Booth - PLN General - 10/19/1994
GARY YANDO,DIRECTOR yON.STgT�o A°u DEPARTMENT OF COMMUNITY DEVELOPMENT i o T i PLANNING -SOLID WASTE-UTILITIES N Y 4 BLDG. III • 426 W. CEDAR • P.O. BOX 578 1864 SHELTON,WA 98584 • (206)427-9670 August 23 , 1994 Aero Controls, Inc. Douglas L. Weeth W. 520 Dayton Airport Rd. Shelton, Wa. 98584 Re: Paint Spray Booth; Building permit number BLD94-1219 . Mr. Weeth: The Mason County Department of Community Development is in receipt of your building permit application and SEPA environmental checklist for the construction of the paint spray booth within the existing main building. The following information will be required. 1. This site is located over a designated "highly critical aquifer recharge area" . A Mason Conditional Environmental Permit is required pursuant to the 'Mason County Interim Resource Ordinance, Chapter 17.01.080 (C) (1) . This permit may require approval and public review by the Mason County Board of Commissioners. The application form is enclosed. There is a $400 .00 filing fee; check should be made out to "Mason County Treasurer" . (I believe the separate SEPA fee of $100 . 00 is still owed as well) . 2 . Information beyond that submitted in the environmental checklist is needed. Specifically, what types of paints, cleaners, degreasers or solvents will be used? Where and how will they be stored? What types of collection devices will be used for waste? What type of disposal system will be utilized? Where are by- products disposed of and by whom? Any other information you could provide regarding the environmental safeguards to be utilized would be helpful, including compliance with state regulations. Please include data regarding the Hazardous Waste Management program you are currently implementing. 3 . The recently approved and constructed addition to the main building was to be used for storage only (to eliminate the need for the conditional use permit) . As the paint spray booth mandates obtaining that permit now, you could include any planned future use of that addition within this permit review if you choose. This would minimize future permitting requirements. (The environmental checklist would have to be revised accordingly) . Please contact this office if you have any questions. We will hold your building permit pending submission of the above requested information. Thank you. Recycled Ib Respectfully, Don Brush, Planner Department of Community Development MITIGATION MEASURES Aero Controls, Inc. Paint Spray Booth 1 . Hazardous Materials - - Property within highly critical aquifer recharge area; applicant shall handle hazardous materials (paints, cleaners, degreasers, solvents) according to state and federal guidelines for these materials and store them as per plans submitted. 2 . Approval from OAPCA and compliance with all applicable requirements set forth by that agency is required. S r-t- E l� Itil o alp � �y 5�. N WX3'xro' �+ S Ghaus} *tuul- 4�'y`�a i 1 �a a irx 24- WHDOWS IT x 547 � b 22- 4TU8E OPEN TYPE FLl1R. FfXTUR.E r 2- {TUBE VAPOR TIGHT FWR_ FIXTURE I- 5H D.L EXHAUST FM - `'` I- .�itiP T. F.C. Id(Ft_ 3-PFI,ISE FIN WAC : EELOC T 204 00 G.I. M.M . 3/8 S.P. VELOCITY 104- Q.P.M. MIN. Ia-� � Is--�' zo•-ct' am VIEW a c b $ b I a {•-d' su--� I r Jr-Er oar _ 4>Is•- "T" r FROW DLEEKE.R BROS. iossm PRM LANE. IYNMOD CALW. 9t o + QUE FLOOR FLTE* a0OTH SD/FILTER ODORS C ix MOM- NO. D" Ill {N8549� Xy{E MEET 1 w 1 d J 1 0�0 � O f � P 1�. L L Llil ( illlllil � ff ► f L + fi I ' liJi �---- ! I ifi IL LL OF] L . L f •� r ' IJ• SzD L,,,YTU A l OX 6?PAY BOOTR 5�1Ai✓K �' • i i ! ! I f i i : I i I � r c� III_ Lf a --�—� --T j-- 1 � re;,D�l- q- FusE-Lrak- 1�5"' z are S1i 410 G L AY FP r P»�`• / \ ` \� 9' '\ FRS'►�u T�z ���tl. \ lie \ �� l -- -- --- - r- -- - ,y• . � ; s� So ,�� 6Gacss v�5;: .moo b.46r.6ctAr I SPEC S � MODEL PCI 25BC � 25BC 256C I 50SC 508C 508C 25ABC I 25ABC 50ABC 50ABC APPLICATION Total Local Local Tank T al Apd. Total Local Tank Total Tank T Side F100d App, Ot31 Tank Agent Quantity 251bs I Side Flood Side Flood Side 251bs 251CS 501bs SOl�.s 501trs 251bs a cent appro%•ai UL. FM.ULC, BSA 251bs 5�lbs 50ios Cylinz:er Specs. DOT. 43350 & 48500 Operating Temp, -20'F through jae F Number Of nozzles 2 N-TF I N-LA25 2 ti-TS ! 4 N_T= I 4 N-LA50 d N-TS Coverage each 2 N-TF 2 N-TS a N-TF 4 pl--g nozzle i �^inaxxi.cu m le , 720ft I 225ft 36ft� 2/ f «s 2f ' ng I36ftz 720ft3 20.=5 ' * 3 idec 20ft 10`t 5ft •;r 2 aft rise 20ft 20:` i0ft 4'0" Max. r 20ft `gt. 20ft �. 20ft 20ft 20ft 20ft 20ft 20ft=0 t 12Cft I B' I 20ft I 11f` S. M,n. r zl 4 a" ?0-t wi h glow restrictor non 6' 9" ' none i o' G- P-7p-r.IqG SPECS. non_ Oft none none � 3' I rune t , ne I i I 4, none none I ncne i on e I ne"ne Max. cylinder to each I I ^ nczzle, length 42ft 53:t 53ft I " 59ft Min cylinder to each 70ft 95ft 42ft F.�ft 47°t I I 7f* 25°_ `5�t I I _ noz .zl e, length I 7ft I 28ft I i6ft 7ft 20ft 5rt I Supply Pipe Size 4 53ft j 3/4" i 3/4" 3/4' 11 clbewg ' t•� firs tee 1 3/4" 1 1 faximum I t0 first tee teen 3/4" t_ 3/4" CyIinaer t0 each nozzle 9 10 1G I 12 i 10 14 I I i0 i2 10 i I � 4 Minimum 4 I 4 2 ; I 3 4 4 I 4 Tee's allowed Cyl- � to each nozzle 1 1 2 2 2 f 1 1 a 2 Max feet of tubing i On a PCI-50 8C system the followinc nozzle �, PAC-10 ; A: 2 N-T= nozzles with 2 N-TS n,zz =;, p` r combinations are permissable: 200ft i 5: 2 N-TF nozzles wi` - C: 2 N-TS nozzles with 2 N-LA50 nozzles. Fusible links `h _ n _A50 nozzles. ( SEE TECH. MANUAL -PIPING LIMITATIONS.) Maximum Links 15 Maximum cable length 100, t Remote pull Max'-mum corner pulleys 20 Mechanical Maximum. cable length 100ft M-, ; cxi-mum corner to -- pui _ys 3/64 dia.cable 20 1/13 dia.Cabl= 17 �_� �,.__ �-, r•!ax1-_.., --able __, -tn 50ft Maximum corner pulleys 15 __aNECUS -,';FORMATION: =ertri0s- �eteCt�Or, Supervisory u ery - p isory circuit, Multiple Cylinder Operation i a at or Elect, :c so_eno:_ -as ,?iv=3 ` ��''i� �t++' � ����/i�,i',t�, t + t e .i ? r �.: ems:` hJ l. j '.x �i 4+, his ,, t+ •1�. l+ I.J.iG� ti•' :;;,f, , ;; ..£� �• ,,r�6�' +�'"" .1'a; i;. �i�., :, �a1FdlY�:l�� ;�. PrO-Enginoored Firs Extinguishing Systems N"Utttbsf: r4arc1 22 1993 To: lluthol-ized PYra C'hOM Inc�uextr3.al. I'r'e~enginoel-c;ci r�.r<, Xtilivishing ^yotomc DivLributorn atss. On 23 Novomber, 1992 , in Sulletin #28, was made m pf'Ufniso to our distributorn. The promise was simple: we would continue 2:0 upgrade our Industrial product lint, until it tyros ihdispuGz�bly thra t;EGT PRE INDUS�i'RJlAL F"Lr SUPPRFSS10M SXSTMI AVATIABLE. We havc3 k0Pt tch0t protnisat Technical supploment No. a (encloi3ed) det: ailt3 thcr r t;ultr,of an ambitioun tooting program which began over one y0 ar ago. V,10 believe tr?.nt those 6•nhancemento angWer this quenti.0115 monk:frequently waked by our distributors, such as: S?y QN i� Why can' t an industrial duct bo protoctcpd l i}tc n restaurant duct, with a 15ingle nazz).a <7t thn duct/planuro trlt�rfe�ccs, Pointing into the duct? '1146 Now -11-t can bey ! The nmw rjnej n 1 N-Et? nos .�1 rf ho.1 ?�srt�n dotsic;riod to be rnountdd tit t.ho duct/ple-111Am inter. race, pointing intc% tho duct, anti can Protect up to ductwork. QU-MUMN-12; Why can't a PC1-50sBC/A13C cylinder be p.�i? with tt�o (2) nozzles, instead Of €'our (4) , to protoot a standard 24 , x 141 x 10' paint spray booth? 11NSW ,R: Now it Can be ! The, PCI-SOsBC can now bo piped with two (2) N-TF noZzlet; and vroi:eat a standard 2.4 ' x 14 ' k Jul point �praay booth. The PCI-50C-A 3C can be Piped with two (2) now N-TF-ABC nozzles and protect a standard 24 ' ac 14 ' X 10, paint �p:-may booth. _, why CZIn't the work arv, of a 261 x 14 ' r IV pnAnC: spray booth be protactrd with a single 500 cylindor? A_N.s'.)'1ER:, Now it can be! noth the vcj-5008C and pC'IV-50PA c cnn protect a 26' x 14 ' x 10' area . Four (4 ) nozzlee aro rc+gtiir-ad for a more evon distribution of powder; howaver, no additional cylinders am requirod . PL,EAS:r 7571, 10il' _1r{,��r,� .r?q Div1S1'?n:tt<�rYr )1.�7 •;'7$'J Reproduction in whole PAGE 2 4 •, RANGE 4 W W o M• or part for personal use or ."FO U NTY 9 14 S H. resale is prohibited by law. ram' O POTL AT C N t7. 7 7. t7.a,5 J 7 ro 28.13 28.97 29.03 29.09 2 ~ 4, SMALL TRACTS I SI P5 I TBR. r� SEC.I SEC.25 ze o _ T. �d r. Lake c �111 5EC.2 3.A. 3CNMK TZ THOMA5 3 g7A JOHP1 Q /. D.MAKOWNEY COAMR./NC. 4.J. LAMPHIEAR P W 5URN£TT SEC.3 !F R TVPPER /( DAYM -AIR RD. W /.LV. BLUCHER F M.LC.L/TTLE O 7.V B(ANAADO -- J 4� SEC.B e.J.&J. COBLE F I.V. 0L50N 9. T wN,TE 39. �- 2.R.SHERMAN a� SEATTLE ,lam /O.J.SM. MLCAFFEAT' FIRST NAIL. .a° SEC.12 //. A. cRuz PORT ' a°- BANK °o l �.' �Sla.,d I.CAPITOL SV(2'S L LOAN /2,L. A1WRED e P MIRHE CY 2.5HIGLEYS h E rRACT5 n.W G/LFS ✓R. �� Lake 3.R. sCLAIV6 %AW If /1 Re"W 4 WOODLAND M/WOR /f V. BR(W(R WOODCAA0 /Y�ANoR NO. 2 /4 J.2.. SANTOS > SHELT Jd' SL aND SEC,13 7. O.GROENNu:ZEN BLANELY LAKE I. MTN. VIEW ADOW y.A. fITZ PATRIC SHORELANDS 2.LAREBURN AOOW 2O. J.THOMAS. 3. MTN:VIEW ADDW L L/.A.AKWIL4MN SEC.17 SEC.26 az Rifle Rare Q.. A I.T. ALLEN I.A 41CNUF'FENHAVEX ' 0 ..11.`'1 2.R.HUL61NGH 2^iEO. BANK(AND ASSOC. O4(. ZQ .Vf VI S.D. aIivA 3. R. PEARSON ? O 4-D.AnAYNARD SEC.Z7 K0 8gy7 , �` SHELTON S.A.PETER50AI ..L.OEEMLR Az gar ` MVNRO ENTER. b.M.PE1vrolvr' S.M.AMTM[NY qZ SAN D E o I, SEC.18 SEC.31 k ~ FIELD I'D. DVAAONTET I MANKE "I.R.CO. PORT ' 2.r. BUECNEL 2.SIMPSON LLSA CO. SHE L n -< S.W. KIRK 3.L. DALE 4.F� A-A4FA5 4.A.SA AROw/I IOR .EN Z 5-K.HURLEY S-A.NED/N R' ��oJ 4.E.4 0. BOYS 6.O. wAAREA FAI ✓�, 7 G- ✓OSSEAANO T G-Werr"GA"Iv B-W..MEA/F/ELD JA. B.C. POPE✓DY 9.Z40-STANF/RD 9, L. SKINNER CO. FAIRGROUNDS N I ��{. �OHN C.KNEELAND /O.5. VOLKE .o. R.S/MMONS `+kt' SEC.19 S EC.35 •,....lv. r Yet At /.VETEAAN5-ADM/N. 4 L.MELLCMA .� Z.M.fR/CK 2.D.S L.fERGVS ON PORT oP ' 9 k D.b L N D.L.C.37 SEC.20 3.A.C✓�+. BAARO SIRELTON A /•E.GR/OLEY 4.E.ERdR30N S M. OL4N0EA ---+� �+ SEC. 21 SEC.36 q1ISub at 10�1 z D. Go1.ay I.L. Come3 3,G. .'TART Z.D.COMBS 4.R.WN/TTAKER D-P. ILOOMMS A.I. YLOOMf,ELO SEC.22 S A.BRACKEN J. KNEELAND I.N.BAOWN (.T.PETERSON Z. A.COLEMAN .3.A.LOERT6c"FA v 4.5.ACKERMAH S.W.~.CORP.OF 5DA L.HERITAGE RED.SV4 OAN S&L C.LAMONT S EC.24 CASCADE MAT. IAC. gALL N 2 ZXCEPT/o A4 A0AEST(RS P 1 3.A'. WA.CoAR OF SDA. l a S b oro j AO? 4._WZLJo-v MoosL IDOGE y .E. S.EA6LE WOOD DIVISION NO./ G� SIMPSON TBR. CO. CITY Or CAT 0. WOKK S«oP N� v - LEGENDLADE - SIMPSON TBR. y�c9 r ,f oTWEL J STATE HYW. 03 U.S ff INTERSTATE Co. 10 ■_■ W PAVED ROADSCX a IMPROVED ROADS �m 3 Fal I&MA , 01: DIRT ROADS -' Co. TRAILS SIM RAILROADS ' �n TBR.CO. CREEKS 0 In ►Cha 5HIPLEY ELEC- PWR. TRANS. LINES " ,,. L. 1 �6►E. NAT L FOREST BDRYS. XXXXXXXZS� ° ra o> °"y 9. . . AEEN a y. C COUNTY BDRYS- / rA ETe uae ea n.oAvisoN RESERVE&GAME REFUGE S1 ON TIMBER CO. 'tG` s UDER CAMPGROUNDS Q PARK& RECR. AREAS "00NO � I�I NILDERNESS AREAS N N s 7 s ) ]IUARD STATION < BANGER STATION 0 L pf� 0 4 11 4k SOV T LOT& ACREAGE �44,9 LTO /jVAL S 5" a o�`' N 3. Is SECTION NUMBERS � 0 'L RSON L. [Yi WNi £ Q 8 R a n. - I I 131 it 14 r MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Planning-Landfill-Utilities MITIGATED DETERMINATION OF NONSIGNIFICANCE (WAC 197-11-350) Description of Proposal : INSTALL SPRAY BOOTH INSIDE EXISTING BUILDING Proponent: AERO CONTROLS INC. Location of Proposal : W 520 DAYTON-AIRPORT RD SHELTON PARCEL#:420027500020 TR 2 OF SURV 13/188 FS 18275:2 HWY 101 NORTH FROM SHELTON TO HWY 102; TURN LEFT GO APPROX 1 1/2 MILES, TURN RIGHT INTO BLDG PARKING LOT Lead Agency: MASON COUNTY The Lead Agency for this proposal has determined that it does not have a probable significant adverse impact on the environment . An Environmental Impact Statement (EIS) is not required under RCW 43 .21C. 030 (2) (c) . This decision was made after review of a completed Environmental Checklist and other information on file with the Lead Agency. This information is available to the public upon request. MITIGATION MEASURES ARE ATTACHED. This DNS is issued under 197-11-350 (2) , the Lead Agency will not act on this proposal for 15 days from the date below. Comments must be submitted by 11/03/94 . , DATE: 10/19/94 Signatu re onsib e official Date Responsible Official : Gary Yando Director of Community Development 426 W. Cedar, PO BOX 578 Shelton, WA 98584 (206) 427-9670 MIT_DNS, rev: 07/07/92 CC: WDOE (Env. Review; Haz. Waste) ; OAPCA; MCEH; Site; Applicant MITIGATION MEASURES Aero Controls, Inc. Paint Spray Booth 1. Hazardous Materials - - Property within highly critical aquifer recharge area; applicant shall handle hazardous materials (paints, cleaners, degreasers, solvents) according to state and federal guidelines for these materials and store them as per plans submitted. 2 . Approval from OAPCA and compliance with all applicable requirements set forth by that agency is required. TO.¢E COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY A. BACKGROUND: 1. Name of proposed project, if applicable: 2. Name of applicant: AERO CONTROLS, INC. 3. Address & phone number of applicant & contact person: 1602 N.W. PIKE ST. AUBURN WA 98001 CONTACT PERSON: BRIAN E. THOMAS 4. Date checklist prepared: JULY 8th 1994 PHONE: (206) 735-3350 5. Agency. requesting checklist:OAPCA (OLYMPIC AIR POLLUTION CONTROL AUTHORITY) 6. Proposed timing or schedule (including phasing, if applicable) : September 5th to Sept. 19, 1994 CONSTRUCTION OF PAINT SPRAY BOOTH 7. Do you have any plans for future expansion, or further activity related to or connected with this proposal? If yes, explain. NO 8. List any environmental information you know about that has been prepared, or will be prepared, directly related to this proposal. NONE 9. Do you know whether applications are pending for governmental approvals of other proposals directly affecting the property covered by your proposal? If yes, explain. YES, A NOC. AND REGISTRAION FORM has been given to OAPCA on May 28th, 1994. 10. List any government approvals or permits that will be needed for your proposal, if known. f/lArSa►J GCJ r1�{ OAPCA NOC AND REGISTRAION FORM. 11. -- Give a brief, complete description of your proposal, including the proposed uses and the size of the project and site. There are several questions later in this checklist that ask you to describe certain aspects of your proposal. You do not need to repeat those answers on this page. (Lead agencies may modify this form to include additional specific information on project description. ) Assemble a UAL approved AUTOMOTIVE PAINT SPRAY BOOTH in our facility to allow Aero Controls, Inc. To spray paint Aircraft parts. The location of this spray booth is in the structure shop. See Site Plan. 1 TO BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY 12. What is the location of the proposal? Give sufficient information for a person to understand the precise location of your proposed project, including a street address, if any, and section, township, and range, if known. If a proposal would occur over a range of area, provide the range or boundaries of the site(s). Provide a legal description, site plan, vicinity map, and topographic map, if reasonably available. While you should submit any plans required by the agency, you are not required to duplicate maps or detailed plans submitted with any permit applications related to this checklist. LOCATION: W. 520 Dayton Airport Road. Shelton WA, 98584 B. ENVIRONMENTAL ELEMENTS: 1. EARTH: a. General description of the site (circle one) : Flat, rolling, hilly, steep slopes, mountainous, �L R other DOES NOT APPLY b. What is the steepest slope on the site (approximate percent slope)? D ew DOES NOT APPLY C. What general types of soils are found on the site (for example, clay, sand, gravel, peat, muck)? If you know the classification of agricultural soils, specify them and not any prime farmland. DOES NOT APPLY d. Are there surface indications or history of unstable soils in the immediate vicinity? If so, describe. /J DOES NOT APPLY 2 TO BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY e. Describe the purpose, type, and approximate quantities of any filling or grading proposed. Indicate source of fill. DOES NOT APPLY f. Could erosion occur as a result of clearing, construction, or use? If so, generally describe. DOES NOT APPLY g. About what percent of the site will be covered with impervious surfaces after project constructions (for example, asphalt or buildings)? S—) 7^l6— DOES NOT APPLY /ju I h. Proposed measures to reduce or control erosion, or other impacts to the earth, if any. : DOES NOT APPLY 2. AIR: a. What types of emissions to the air would result from the proposal (i.e. dust, automobile, odors, industrial wood smoke) during construction and when the project is completed? If any, generally describe and give approximate quantities, if known. We will be emitting odors and air toxins or other VOC's after they are filtered through the Spray Booth Filters. b. Are there any off-site sources of emissions or odor that may affect your proposal? If so, generally describe. There are no off site sources of emissions. C. Proposed measures to reduce or control emissions or other impacts to air, if any: Filtered Spray Booth which will be inspected and maintained regularly. 3 TA BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY 3. WATER: a. Surface: 1) Is there any surface water body on or in the immediate vicinity of the site (including year-round and seasonal streams, saltwater, lakes, ponds, wetlands)? If yes, describe type and provide names. If appropriate, state what stream or river it flows into. Ak DOES NOT APPLY 2) Will the project require any work over, in, or adjacent to (within 200 feet) of the described waters? If yes, please describe and attach available plans. DOES NOT APPLY 3) Estimate the amount of fill and dredge material that would be placed in or removed from surface water or wetlands and indicate the area of the site that would be affected. Indicated the source of fill material. DOES NOT APPLY 4) Will the proposal require surface water withdrawals or diversions? Give general description, purpose, and approximate quantities if known. DOES NOT APPLY 5) Does the proposal lie within a 100-year floodplain? If so, note location on the site plan. DOES NOT APPLY 6) Does the proposal involve any discharges of waste materials to surface waters? If so, describe the type of waste and anticipated volume of discharge. �1 DOES NOT APPLY 4 TO BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY b. Ground: 1) Will ground water be withdrawn, or will water be discharged to ground water? Give general description, purpose, and approximate quantities, if known. DOES NOT APPLY 2) Describe waste material that will be discharged into the ground from septic tanks or other sources, if any (for example, Domestic sewage: Industrial, containing the general size of Nam; the system, the number of such systems, the number of houses to be served (if applicable), or the number of animals or humans the system(s) are expected to serve. DOES NOT APPLY C. Water Runoff (including storm water) : 1) Describe the source of runoff (including storm water) and method of collection and disposal, if an (include Cx�srr� p , y quantities if known). Where will this water flow? Will this water flow into other waters? If so, describe. DOES NOT APPLY 2) Could waste materials enter ground or surface waters? If so generally describe. DOES NOT APPLY d. Proposed measures to reduce or control surface, ground, and runoff water impacts, if any: DOES NOT APPLY 4. PLANTS: a. Check or circle types of vegetation found on the site: _x deciduous tree: alder, maple, aspen, other x_ evergreen tree: fir, cedar, pine, other _X shrubs _ X grass pasture crop or grain wet soil plants: cattail, buttercup, bullrush, skunk cabbage, others water plants: water lily, eelgrass, milfoil, other 5 TO., BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY b. What kind and amount of vegetation will be removed or altered? DOES NOT APPLY C. List threatened or endangered species known to be on or near the site. DOES NOT APPLY d. Proposed landscaping, use of native plants, or other measures to preserve or enhance vegetation on -the site, if any: DOES NOT APPLY 5. ANIMALS: a. Circle any birds and animals which have been observed on or near the site or are known to be on or near the site: birds: hawk heron, eagle, son birds other mammals: deer, bear, elk, beaver, other fish: bass, salmon, trout, herring, shellfish, other b. List any threatened or endangered species known to be on or near the site. NONE C. Is the site part of a migration route? If so, explain. NO d. Proposed measures to preserve or enhance wildlife, if any: DOES NOT APPLY 6. ENERGY AND NATURAL RESOURCES: a. What kinds of energy (electric, natural gas, oil, wood stove, solar) will be used to meet the completed project's energy needs? Describe whether it will be used for heating, manufacturing, etc. The Spray Booth will be used for manufacturing and Aircraft parts repair. This spray booth will be connected to Electricity so as the exhaust fan will operate to remove paint spray and fumes through the filter banks and then emit the fumes outdoors. 6 TO HE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY b. Would you project affect the potential use of solar energy by adjacent properties? If so, generally describe. NO C. What kinds of energy conservation features are included in the plans of this proposal? List other proposed measures to reduce or control energy impacts, if any: NONE TO MY KNOWLEDGE 7. EHVIROHliEHTAL HEALTH: a. Are there any environmental health hazards, 0Z10�'�� including exposure to toxic chemicals, risk of fire and explosion, spill, or hazardous waste, that could occur as a result of this proposal? If so, describe. Hazardous waste will be generated in the mixing of the spray paint and cleanup. The risk of fire is present with the fumes of the spray paint. We currently have a Hazardous Waste Management program set up to dispose of any waste properly. See Contact person. 1) describe special emergency services that might be required. Fire Crews: The spray booth will be connected to the building fire alarm system, and if any fire is started, the Fire Department will be notiifed promply. 2) Proposed measures to reduce or control environmental hdalth hazards, if any: Maintaining our current Hazardous Waste Management Program, and periodical maintenance and inspections. b. Noise. 1) What types of noise exists in the area which may affect your project (for example: traffic, equipment operation, other)? The exhaust fan operation when the spray booth is in operation. 2) What types of levels of noise would be created by or associated with the project on a short-term or a long-term basis (for example: traffic, construction, operation, other)? Indicate what hours noise would come from the site. Hours of Operation: Mon-Fri: 07:OOAM-16:30PM Sat: 07:OOAM-15:30PM The duration of the Noise Levels will be short term. 7 TO_BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY 3) Proposed measures to reduce or control noise impacts, if any: We will control noise levels by only operating the spray booth during business hours. a. LAND AND SHORELINE USE: a. What is the current use of the site and adjacent properties? Wharehouse storage and Aircraft parts repair . Adjacent Properties: No current usage. 4- P�cL. b. Has the site been used for agriculture? If so, 57W ovo vy describe. no C. Describe any structures on the site. One L-shaped building that is 75,000 sq ft. in total area, split up by fire walls with the warehouse being 45,000sq ft and shop 24,000 sqft. d. Will any structures be demolished? If so, what? Office area 6,000sgft. NO e. What is the current zoning classification of the J� site? ^/ INDUSTRIAL USAGE f. What is the current comprehensive plan designation of the site? DOES NOT APPLY g. If applicable, what is the current shoreline master program designation of the site? DOES NOT APPLY h. Has any part of the site been classified as anQ��� 'environmentally sensitive* area? If so, specify. NONE i. Approximately how many people would reside or work in the completed project? Total employee for the operation of the business is 40 to 45: There will only be one person at a time in the spray booth. J. Approximately how may people would the completed project displace? none 8 7'p BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY k. Proposed measures to avoid or reduce displacement impacts, if any: DOES NOT APPLY 1. Proposed measures to ensure the proposal is compatible with existing and projected land uses and plans, if any: File the proper applications and permits for the installation of the spray booth. 9. HOUSING: a. -Approximately how may units, if any, would be provided? Indicate whether high, middle, or low- income housing. DOES NOT APPLY b. Approximately how many units, if any, would be eliminated? Indicate whether high, middle, or low- income housing. DOES NOT APPLY C. Proposed measures to reduce or control housing impacts, if any: DOES NOT APPLY 10. AESTHETICS: a. What is the tallest height of any proposed structure(s), not including antennas; what is the principal exterior building material(s) proposed? N EXTERIOR sheeting of the building is Sheet metal and the tallest portion of the building is 24ft. The building measures 400ft x 450ft b. What views in the immediate vicinity would be altered or obstructed? NONE C. Proposed measures to reduce or control aesthetic impacts, if any: does not apply 11. LIGHT AND GLARE: a. What type of light or glare will the proposal produce? What time of day would it mainly occur? The spray booth has built in 4 tube vapor tight flur. fixtures, 2 ea and 22 ea 4 tube open type flur. fixtures. 9 TO BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE.ONLY b. Could light or glare from the finished project be a safety hazard or interfere with views? NO C. What existing off-site sources of light or glare may affect your proposal: NONE d. Proposed measures to reduce or control light and glare impacts, if any: NONE 12. RECREATION: a. what designated and informal recreational opportunities are in the immediate vicinity? NONE b. Mould the proposed project displace any existing recreational uses? If so, describe. NO C. Proposed measures to reduce or control impacts on recreation, including recreation opportunities to be provided by the project or applicant, if any: DOES NOT APPLY 13. HISTORIC AND CULTURAL PRESERVATION: a. Are there any places or objects listed on, or proposed for, national, state, or local preservation registers known to be on or next to the site? If so generally describe. NONE b. Generally describe any landmark or evidence of historic, archaeological, scientific, or cultural importance known to be on or next to the site. NONP. C. Proposed measures to reduce or control impacts, if any: DOES NOT APPLY 10 ` 'TO BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY 14. TRANSPORTATION: a. Identify public streets and highways serving the site and describe proposed access to the existing street system. Show on site plans, if any. DOES NOT APPLY b. Is site currently served by public transit? If not, what is the approximate distance to the existing street system. Show on site plans, if any. DOES NOT APPLY C. How many parking spaces would the completed project have? How many would the project eliminate? DOES NOT APPLY d. Will the proposal require any new roads or streets, or improvements to existing roads or streets, not including driveways? If so, generally describe (indicate whether public or private). DOES NOT APPLY e. Will the project use (or occur in the immediate vicinity of) water, rail, or air transportation? If so generally describe. DOES NOT APPLY f. How many vehicular trips per day would be generated by the completed project? If known, indicate when peak volumes would occur. DOES NOT APPLY g. Proposed measures to reduce or control transportation impacts, if any: DOES NOT APPLY 11 TO''BE COMPLETED BY APPLICANT EVALUATION FOR AGENCY USE ONLY 15. PUBLIC SERVICES: a. Would the project result in an increased need for public service (for example: fire protection, police protection, health care, schools, other)? If so generally describe. Fire protection would be required: but the spray booth will be connected to a fire suppression system and alarm panel to activate in case of a fire inturnaly or stop the operation if a fire is b. Proposed measures to reduce or control direct detected else where in the building. impacts on public services, if any: DOES NOT APPLY 16. UTILITIES: a. 99NS95W tly available at the site: s, water, refuse service, rer, septic system, other. b. Describe the utilities that are proposed for the project, the utility providing the service, and the general construction activities on the site or in the immediate vicinity which might be needed. Does Not Apply 17. SIGNATURE: The above answers are true and complete to the best of my knowledge. I understand that the lead agency is relying on them to make its decision. Signature:""�fAIA J�A '-4 &Ld Dir ctor of Operations Date Submitted: 12 Al be F S`l) L �; 7 RLIC TU. p try N , y�/ L I S'x 3d'X93' Wx3'xIo" i 0� i - �d L� H01E S �a a 24- WlH DOWS I T X W g b 22- 4TU6E OPEN TYPE FLUB. E(iC1UR.E t - Z— 4TUEE VAPOR TIGHT FWR. FIXTURE Lrl " I— 5HP T.J=F.C. idTi2. 3—PHASE FM WAC : EELOC ST 204 F.P.M.G.tM.M 03/9' S.P. YEL4CIiY t04 F . 1,(1N_ ta--rf tio•-o to•-cr' a 5 $ b F1 I a i 4•--0- 3(Z'-f!' I t jr—tr DO(JF� - ---J I �e•- WOTH r - rt�arr aFu,anK B".KKER B.R D S. j 1 D662 ORUR'Y tAKE. IY WOOD CALIF. 90 d Q FLOOR FILTFA AOOTH tY/FILTER ODORS 1.�0[Ei NO, d40 IA. ►1�35 49 a 1CHE StIffF 1 Or 1 1- --1 n 0 �c ca f— � 0 - r I -c► 76.s �vro _ b8S8b ��1 " }lays _ _ rb..tyodvly MAIN o75 -T PrEAD A, lc)• SZ!? c. Y-ro ni 4 I RPX-r Noc# sgz k SPRY 13DOT14 1 �✓ i•' is I i i FZF !t^ — I 11 � 1 I IAL SPEC.S MODEL PCI # 25HC 25SC 256C I _ 50BC 508C ABC APPLICATION Total �08C 25ABC I 50ABC 50ABC Flood Apo. Side ank TOta1 Local Tank Agent Ouantity 251b5 Tank Total Tank 7 Flood App. Side Otal Side Flood Side Flood 251Ds 25iCS 501bs SOIc.s Agent Approval 501bS 251bs 251b5 1501DS 501b5 UL. FM.ULC. BSA Cylinder Specs. DOT. 4B350 & 485CO Operating Temp, -20`F through 12e F Number Of nozzles 2 N-TF 2 N-La25 2 N-TS 4 N-TF I 4 N-LA50 4 N-TS 2 N-TF 2 N-TS Coverage each N-TF 4 ,1--S �nozzle axirum lengt„ 72oft' 25r_2 3Sft' 2ft3 I 25ft' 35ft z 72 3 -Cr ' a One Side I Oft 20._ t� � ,�`cr i 0.2tft loft 5ft oft loft 5ft I I i "ax. ertiG=1 Eft i0ft 4'e, loft rise 20ft `= 20ft I a r 2C, , Max. :,:Ozzie Hgt. 2Qct I !1;t Of` 20ft 20ft 2 I i 8„ I fort I Oft 20ft 2Cft j 2of- -zl� an,e 11 6" 20rt 8" coft 8„ with =low restrictor none I 6' 9' ?" none i ti' 3' PIPING SPECS. 4 t none none I 4f I cone - nine I j t none none I none i .One ! none Max. cylinder to each I i ^ nozzle, length 42ft 53- . �3rt 5grt 701- 95ft 42tt 4-1 I c'2ft g5ft Min. cylinder t0 each nozzle, length 7ft 25ft 25ft ( 7ft I 28ft 16ft 7ft 20ft 45ft I 53ft Supply Pipe Size 3/4- 3/4" 3/4' E1bOwS I 1 _ f i.. 1" 3/4' 3/4' t 1, first tee I i to first tee t,, Maximum en 3/4" then 3/4" Cylincer to ieach nozzle 9 10 40 I 12 i 10 14 9 i0 I i2 I 10 Minimum 4 I 4 I 2 I 3 4 4 I y i 2 Tee 'S allowed Cyl- � to each nozzle 1 1 1 2 I 2 I i 2 i 2 � 2 Max feet Of tubing I On a PC!-=O SC system the rollowing nozzle air PAC-10 A: 2 N-T= nozzles with 2 N-TS rOZ; P-. combinations are permissabie: 200rt 2 •1_T- nozzles wig -i _, n - C: 2 N-TS nozzles with 2 N-LA50 nozzles. `h - _a5 rczz_Es. ( SEE TECH. MANUAL -PIPING LIMITATIONS.) Fusible links 0 S.) Maximum Links 15 Maximum Cable length i00ft Remote pull Maxi-mum Corner pulleys 20 Mechanical Maximum, cable length i00ft M-. +' corner �o �`-,"u , Dui2eys 3164 dia.cable 20 1/13 dia.Cab 17 Sir: maximum corner pulleys 15 MISr_LLANECUS I\FORP4ATION Ei2Ctrica_ Cetection Supervisory ' P isory circuit, M'.:ltiple cylinder Operation =1 le ectric so no:_ gas vai la, F. TV ��' t ••L r�1 1a N'6+ 1' y r t r k h f 1( �f� f t t u ����'J �, 4+e k �*!F`y�9 !h�f•r ,1.��+iy�y�+�f '1.. °�. 4%L !: Pry*-EnginOOmd Rro Extinguishing Systems � h to r..ft • .�t7^.cif QatO:March 22, 1993 TO: Authorized PYr c Chem 1ndvstr3.n 1 fir. Q-nn�f i nr7ea-raci r!.re:)ttittr,±aiWhi,nq sy {ts,y� (�it:t ri�autc a-z� On 23 Novomber, 1992 , in gullet:in #20, ws made a prt7misr to our distributors. ThL, promise was simple: we would continue ;:o upgrade our Industrial product lirle until( it tiros ihdispuCnbly thf, REST PRE-ENGINEPRED INDUSTRIAL FJ.F2L SUF'fiRFSS,fUN SXSTFf`1 AV11ILABLE. We h€ava kept that protnisn 1 Technical arupploment No. 8 (enclot3ad) dotailra t1ho rep ultg Of an 1a,mbitioun tooting program which brogan over one year Ago. Vde believe that these enhancernentq answor the gtaoati.ons most frequmntly asked by our distributors, such nss OV-44TJ:)N 0, Why can't an industrini duct bps protp*ctocl 1 i)co to restaurktrtt duct, with a singlo nozzlo at th* duct/1a10nurt intaarfaccs, Pointing into the duct? ���% : Now it can b©! The nnta Pjoejar�l N-a;t? noT;-t�f hh�, rlr�tsic MOO to be mountdd at thca duct/plcno,tm inter race,ice, Pointing into they duct, and can protect up to 2-�--qsLG of ductwork. Q-U-B�UToWILf'-2_ why. can't a PCI-50sBC/fi13C cylinder be v1pod with two (2) nopzlas, instead of four (4) ► to protoot a standard 24 ' x 141 x 10' paint spray booth? 1lNS9 R: NOW it can Ile ! The FOCI-50s8c can now bo pipc3d with two (2) N-TF nozzles and protect a standard 24 ' 2c 14 ' x lo' paint 'spray booth. The PCI-�OaABC can be Piped with two (2) flaw N-TF-ABC nozzles and protect a standard 24 ' x 141 x 10, pai►zt spray boot,,. why COn"t the work area of a 26 , x 14 ' x lo, pninz: spray booth be protocyted with a single 504Y cylindor? byswi Now it CAM bee troth the E'CI-5btzOC and fi(:'i�-50n�11^�C cr�n protect a 261 x 14 ' x 1o' area . Four (4 ) nozzles: ia>ra regtjir.ad for a more even distribution or powder; however, no ac4ditir,nrol cylinders am requirod. P1Z-A5 _ '1±+AIJ TiiLCe .FI..LXC7�t �t 0ti ,�:.g7�'J tj�nl+ir'El,i��tn Ir^;p.tl. _ ... ,'Sf •r Reproduction in whole PAG E 2 q ., RANGE 4 Wo VAT. M• or part for personal use or :O U NTY 9 ASH. resale is prohibited by law. ram' so O POTL AT C H f ' 27. 7 7. 27.39 7 6 28.18 z8.97 29.03I 29.09 ~ SMALL TRACTS SI PS TOR. 111 SEC.I 5EC.25 I. H. WILSON I. K. BESELIN 2.T LN. _ ; o _ _ BROOKS 'LJ 1,- C C n Lake SEC.2 S.A. xNMALTZ /. O.MAKOYINEY CONTR.IAC. THOMA5 3 STATE JOHfI Q J. uMPNIEAR �+. W 5VRNETT SEC.3 s R.TYPPER W M.LC.L/774Z IC D.4YT0 -AIR Irv. - F O / W. BL[ICNER 7,V BLANAROO / SEC. Tur2`/e Lh. F I.V. OLSON B.'/tJ COBLE ny I n 10� 1, 39. t' 2.R.SNERMAN 9. 7. WN/T! J,l �� SEATTLE /o.d.tM. M�'CAFFERTY PORT Z �1v FIRST NATL. •aP SEC.12 ++. A. CRYZ O ` T WAINK " /s/and J.CAPITOL SWS C 40AH 12.1 K/NAEO Ca0 y M+RNf CT 0 2.3N/GLEYS HOME TRACTS q.W. CKES ✓R. �0 �I♦{ �G Lake 3.R.SGHw/ETCRINO +4.M. u77LE N` 4 WOODLAND MA^i0R /f. Y. BREW(R ^� J S.WOOOLAND MANOR No�2 /V' J.!B. SANTOS > O� /7. D.GROEM/U:ZEN SHELT SLAND SEC,13 g, C.couywa BLAKELV LAKE /. MTN. VIEW ADO'N y.A. /rT2 PAIR/C _ Q MLA CA. !• SHQRELAN05 2.LK AEBURN AVOW 20. J.THOMAS. A MTN:VIEW AOOW Z L.A.M•WILLIAN 5 SEC.17 SEC.26 Rifle Range I_ + p' 3 AT. ALLEN I.A. SC/VACENNAUER 0 ': 2.R.NML°/NON 2^4'ED. SANK LAND ASSOC. VI B.O SINA 9. R. PEAASCW I� O o ^ e �' ` yiQ 4.D.A"YNARD SEC.27 ,( 5HELTON L.K.PE7ER°ON ..L.DEEMER ?- .0 - ` 'A• ,�9 .'�i: ENTER. i.M.PEIVro/vr z.M.MA7WLNY MVNRO q� SANDE so t �� SEC.18 SEC.31 DlIM FIELD 4 I.D. ONTE AT I A OC LBW.CO. PORT T 2. B&zC vx4 2.b/M N PSO LBR Co. `o �.' •: SHEL s < S.W ICIAK 3.L. DALE 4.f. RANDLEr S 4.A.2P.BROWN u 'B EN yy 5-K.HOALEY 5.R.NEO/H &.E.2 LL BOYS re.D. WA<KER I'A+R' (SRO •3��/J, 7.G J09$CRANO 7. G.Wl7TERGRCLN S.W.mEA/F/ELD JR. B.C. POPE✓DY 9.E40.STANF/RD S.L. SKINNER CO. FAIRGROUNDS J' i. JOstN C.KNEELAND Io.5. VOLKE p. A.31MMONs N IJAr+D SEC.19 SEC.35 .'y.:•.. I.VETERANS ADM/AI I.a.MLLLEMA r vel Pt. 2.M.FR,CN 2,0.t L.FeA WSON S.A.C/M. BRAND D.,b ¢ M D.L.G.37 SEC.20 4. SHELTON �' A I.E.GR/OLEY S S X.LRKXSON _ M.OL4NOLA -•- •-•w �If Sub a 1.L io-n I.D. WALKER I.c. COMB C 21 SEC.36 2.O.S,agvr .G. NART HART 2.D.COMBS tiL - * 4.R.WN/TTAKE.R S.MI.i LOO-I'Ar A. . aLIAMSLD Y. SEC 22 S R.BRACKEN J. KNEELA"D Per,"CN „ 2.A. OLLMAN �.B.LOERTSCNER 4.5.ACKERAJAN S.W.WA.CORP.OF SOA i.I/ERITAOr fED.3✓63&LOAN CA C 7 C,LAAZONT S EC.24 hy I.CASCADE MAT,wC. 9 ALLAN N' Z E2CEPTl*OVAL AGR63TlR3 Pryp��� J•2 3.W. WA.CORP OF 3DA. bOro 7 I 0+ 1 4.SNE<7bv MovOL 1..00E S d �� r S.EAW.EW.00 ONIS/oN NO./ SIMPSON TBR. CO. CITYQ� • O CI Of UTYO� WONK G 'S 6 Ck INC. LEGEND - SIMPSON TBR. y TF ,� OTWEL ` STATE HYW. 03 U.S INTERSTATE CO. 1e PAVED ROADS � B C'''� IMPROVED ROADS Fal &M NI ❑C°i DIRT ROADS 3 � CO. TRAILS - - SiMPSO o TBR.CO. RAILROADS �n Ma lock N a R. 5 CREEKS I ` ,o Y v Int rCha SHIGLEY ELEC. PWR.TRANS. LINES 1 �1% NAT L FOREST BDRYS. tc, IT /DEEN 3t e asb� Qf FOREST SERV. RD.NO. 9°" 5 COUNTY BDRYS. !, J A.W150H • . . MILTF NHE ea RESERVE&GAME REFUGE �I G` CAMPGROUNDS t' S1 ON TIMBER CO. STUDER Q PARK& RECR. AREAS f FTz 101 NILDERNESS AREAS eINCH aUARD STATION OJAIT0 9 s O RANGER STATION 4 0o 30V T LOT & ACREAGE 4479 SM LTON�VALLS RD p •l--41 J� � �3. /4 f` L WN F SECTION NUMBERS � 0. 'L RSON I � Q- RQ ., - At n d November 9, 1994 To: Gary Yando, Director DCD From: Don Brush Re: Mason Environmental Permit Applicant: Aero Controls Proposal : Placement of 18 foot by 34 foot by 12 foot tall paint spray booth within existing building. Property Location: W. 520 Dayton-Airport Road; Tract 2 of Survey 13/188 ; Section 2, Township 20N, Range 4W. , W.M. I. Interim Resource Ordinance: Located over "highly critical aquifer recharge area" . Applicable requirements include need for Mason Conditional Environmental Permit and SEPA compliance. An administrative review process is recommended due to the fact that this is a relatively undeveloped area and the area generally consists primarily of light industrial development. The fully contained nature of the structure severely limits the likelihood of any impacts to the aquifer as a result of this proposal . II. SEPA Compliance. Mitigated Determination of Nonsignificance issued October 19 , 1994 . (Site posted) . 1 . No comments received from outside agencies . 2 . No comments received from the public. 3 . Olympic Air Pollution Control Authority. Notified Mason County by telephone that a separate permit is required through that agency once local review is completed. NOC filed 5/28/94 . 4 . Mason County Health Department. Noted that the amount of waste generated brings the operation into the jurisdiction of the state. 5 . Mason County Building Department. Approved plans as submitted. 6 . Mason County Fire Marshall . Approved plans as submitted. Condition: 1. A separate permit is required for the installation of the fire suppression system for this booth. Have Firesafe submit plans and apply for a permit. 7 . Mason County Public Works . Project contained within existing structure which has received approval for stormwater retention system. III. Hazardous Waste. Applicant is registered with the EPA, Identification number WAD988517074 . Vendors used for disposal of waste are approved by the Dangerous Waster Regulations Chapter 173- 303 WAC - - Envirotech and Safety Kleen. IV. Analysis. The applicant has submitted a statement indicating which hazardous materials are to be used and stored on site. All paints, cleaners and solvents will be stored within Flammable Safety Cabinets. The paint spray booth is entirely self-contained and contains its own fire suppression system. V. Conclusion. Staff recommend approval of the Mason Conditional Environmental Permit subject to the following conditions: 1 . Hazardous Materials - - Property within highly critical aquifer recharge area; applicant shall handle hazardous materials (paints, cleaners, degreasers, solvents) according to state and federal guidelines for these materials and store them as per plans submitted. 2 . Approval from OAPCA and compliance with all applicable requirements set forth by that agency is required. Approved: Not Approved: Gary Y o r ctor, Department of Community Development Date 1 �r, FAA Certl F;-Bed Repair Station No. R _ AUG 0 5 1994 AER0 CONTROLS, INC. -- MASON CO. KkRNING DEFT. August 5th, 1994 Mason County Building Department 426 W. Cedar Shelton Wa, 98584 To Whom It May Conern; Enclosed is the Environmental Check List Application that is requested by the Olympic Air Pollution Control Authority. This Check List is for the Construction of an automotive U.A.L. approved Spray Booth within our shop facility. Please review this check list so as we may start construction as soon as possible. If you have any questions please contact me at 427-5441 . Thank you, �,J v- Dou as L Weeth Aero Contorls, Inc . Shelton Division 1602 Pike Street N.W. • Auburn,WA 98001 • Phone:(206)735-3350 • Telex:62897575 • Fax No:(206)939-0530 FORM•ACF-23 AERO Cwnuoiis, INC. September 9th 1994 Department of Community Development Gary Yando Bldg III 426 Cedar P.O. Box 578 Shelton Wa 98584 RE : Building permit #Bldg 94-1219 : Environmental Permit Application Mr. Yando: In response to your letter written to me on August 23rd, 1994, the SEPA fee was turned over to our Accounting Dept . in Auburn Wa . After which I requested a check to pay the fee. I should have the check within two weeks . In reference to Item 2, of your letter. See attached sheet for the types of paints, cleaners, degreasers or solvents that we are currently using. This list will also indicate the anticipated quanities for one complete year after our spray booth has be assembled and used. We are using Flammable Safety Cabinets to store all of our paints, cleaners, and solvents . Our degreasers are contained in 30 gal . drums attached to parts washing tanks . We are using 55 gal . drums to store our waste products . We use vendors that are approved by the Dangererous Waste Regulations Chapter 173-303 , WAC. Two of which are Envirotech and Safety Kleen, to dispose of our waste . We are registered under the above regulations, and our EPA I .D. number is WAD988517074 for our operation on W. 520 Dayton Airport Rd. and the EPA I .D . number is WAD988504288 for our operation on Sanderson field. pg 1 1602 Pike Street N.W. • Auburn, WA 98001 • (206) 735-3350 • Telex: 62897575 • Fax Na: (206) 939-0530 AER0 COYMOrs,ANC. In respose to Item 3 : Our new addition will be used strictly for warehouse storage . Once this space is available we will begin to empty out the exiting warehouse and start to set that space up for repair work on aircraft parts . This expansion in the existing space will require updated electrical wiring for the Spray Booth and other mist . equipmet . We are planning on using about 15 employees in this area when it is complete . We will also be putting in some test equipment in the space vacated by the existing shop, when that shop moves into the old warehouse area. This test equip- ment will also require electrical updating. This updating will also concur with the updating of the old warehouse space . I hope that this letter will answer your questions . If you have any further questions, please call me at 427-5441 . If you have any environmental questions, please call (206) 735-3350 and ask for Brian Thomas who is the Director of our Hazadous Waste Management program. Sincerely yours, 4 �� ou as L. Weeth Dir ctor of Operations Aero Controls, Inc . Shelton Divison Encl : Paints, cleaners, solvents, and degreaser list . Pg 2 1602 Pike Street N.W. • Auburn, WA 98001 • (206) 735-3350 • Telex: 62897575 • Fax Na: (206) 939-0530 AcRo Commom INc. September 12th 1994 . Ref : Bldg Permit #Bldg 94-1219 : Chemicals, Cleaners, Adhesives, Fluids and Degreasers Inventory NOMENCLATURE CURRENT STOCK ANNUAL USAGE PAINTS AND ADHESIVES : TL-59 Reducer 1 gal . 2 gals . TL-52 Reducer 3 gals . 2 gals . BMS 10-11 Green Primer 9 gals . 48 gals . BMS 10-60J Gray Top Coat 1 gal . 12 gals . BMS 10-60 White Top Coat 0 gal . 2 gals . BMS 10-79 Yellow Primer 0 gal . 1 gal . BMS-1086E Reducer/Thinner 1 gal . 1 gal . BMS-1086F Teflon 1 gal/lpt . 2 gals . BAC 5010 TYP2 Primer 2 gal . 4 gals . Epoxy Adhisive 2216 A&B 1 qt . 2 qts . Epocast 1511 A&B BMS 5-28 VTY-3 1 Kit/2 lbs 2 Kits/4 lbs . Epocast 1636 A&B BMS 5-28 VTY-6 1 Kit/2 lbs 2 Kits/4 lbs . Epocast 1616 A&B BMS 5-28 TY-16 1 Kit/ qt . 3 Kits/4 qts . 5 min. Epoxy 2 ea/ 5 oz tubes 12 tube kits . BMS 5-126G 2 gal Kit 2 gal Kit SOLVENTS AND CLEANERS : Methyl Ethyl Ketone 5 gals/55 gals . 55 gals . Isopropyl Alcohol 5 gals . 10 gals . Safety-Kleen 105 solvent 15 gals . 60 gals . Inland Chem. solvent 20 gals . 60 gals . Acetone 0 10 gals . Turco 5351 paint striper 5 gals . 15 gals . Tolulene 5 gals . 15 gals . Mineral Spirts paint thinner 1 gal . 1 gal . Dye Check Cleaner/remover 12 ea/9 oz cans 48 cans . Dye-Check Developer 25 ea/9 oz cans 6 cans . Dye-Check Penetrant 14 ea/9 oz cans 4 cans . (dip tank solution) 5 gals 15 gals PG 1 . 1602 Pike Street N.W. • Auburn, WA 98001 • (206) 735-3350 • Telex: 62897575 • Fax No.: (206) 939-0530 i AFRO CONTROLS, INC. NOMENCLATURE CURRENT STOCK ANNUAL USAGE SOLVENTS AND CLEANERS : CONTINUED LPS-3 Rust Inhibitor 5 gals/4 ea 12 oz cans 15 gals/48 ea cans WD-40 3 ea/15 oz cans 24 cans . Aero-Kroil 2 ea/10 oz cans 12 cans . Kano-Kroil 5 gals . 15 gals . GREASES AND LUBRICANTS : Hydraulic Oil HO-3 PT-76460 5 gals . 5 gals . Hydraulic Oil Skydrol 500 5 gals . 5 gals . Hydraulic Oil MIL-H-5606 2 qts . 2 qts . Grease MIL-G-23827 2ea/35 lbs/5 gals 35 lbs . Grease #33 Dow Corning 4ea/5 . 3 oz tubes 12 tubes Grease Royco C-627 MIL-C-11796 lea/3 lb can lea/3 lb can. Air Compressor Oil 1 qt . 6 qts . Dry Film Lubrication #321 Dow Corning 1 ea/11 oz can 6 ea/11 oz cans . Ease Off 990 High Temp Anti-seize lqt 1 qt . MISC. PRODUCTS : Alum-A-Prep DX533 0 gals . 12 gals . Alodine 1200 1 gal . 24 gals . Flitz Metal Polish 3 qts . 6 qts . SEALANTS : BMS 5-95 Sealant 1 ea/9 oz tube 24 ea tubes . BMS 5-95 Sealant 4 ea/12 oz cans 24 ea/12oz cans . RTV Gray Sealant 5 ea/2 . 8 oz tubes 6 ea/2 . 8 tubes . 736 Red Heat Resistant sealant Dow Corning 0 /10 . 5 oz tubes 2 ea/ 10 . 5 oz tubes . PG 2 . 1602 Pike Street N.W. • Auburn, WA 98001 • (206) 735-3350 • Telex: 62897575 • Fax No.: (206) 939-0530