Loading...
HomeMy WebLinkAboutMIS94-0710 Automatic Fire Alarm - MIS Permit / Conditions - 9/9/1994 MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 M = S C E L L A N E O U S P E R M I T FOR INSPECTIONS CALL 427-9670 MIS94-0710 PARCEL : 420027500020 PLAT : DIV : BLK : LOT : JOB ADDRESS : W 520 DAYTON—AIRPORT RD SHELTON APPLICANT : JOHN TITUS 735-3350 OWNER : JOHN TITUS 735-3350 L E G A L : TR 2 OF SURV 131188 FS 18115:2 PROJECT DESCRIPTION : AUTOMATIC FIRE ALARM PROJECT LOCATION : HWY 101 TO HWY 102 LEFT GO 2 MILES TWO DRIVEWAY PROJECT NOTES : TYPE AMOUNT BY DATE RECEIPT PRMT $ 50 . 00 KS 09/09/94 0071 TOTAL : 50 . 00 OWNER OR AGENT DATE MIS_PRMT, rev: 64/01/92 I L f I►�� `f 77 Zoo2- ,5 A00 M MASON COUNTY FIRE MARSHAL Mason County Bldg, III 426 W.Cedar P.O. Box 186 Shelton,Washington 98584 (206)427-9670 CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION AUTOMATIC FIRE ALARM SYSTEM ACCEPTANCE TEST REPORT ADDRESS____ IS __ _ �LI1 - --- -- ------- ------------------- 0 C C U P ANT_ G � 0,1�2-------------P H O N USE-------- 6_p '----- FIRE ALARM CONTRACTOTR_ PHONE CONTACT_ INSTALLER PLANS & PERMIT ON SITE YES NO PERMIT # CONTROL PANEL MFR__�j_6d V MODEL INITIATING CIRCUITS NO. OF SIGNAL CIRCUITS 2- BATTERY VOLTAGEienIVOLTS CHG.CIRCUIT VOLTAGE VOLTS BATTERY VOLTAGE UNDER FULL LOAD VOLTS (SIGNALS OPERATING) TROUBLE SIGNAL WITH AC POWER OFF: YES NO Zane 2— SYSTEM OPERATES ON STANDBY POWER: YES NO N/A Z" 3 - � ALL SIGNALS OPERATE ON AC POWER: YES—NO—N/A ALL SIGNALS OPERATE ON STANDBY POWER: YES NO N/A ------ ALL CIRCUITS CHECKED FOR ELECTRICAL SUPERVISION: YES NO N/A T3 - - - - CONTROL PANEL CHECKS MADE PER NFPA & MFTRS. INSTRUCTIONS: YES—NO—N/A ALL AUXILIARY EQUIPMENT OPERATES: YES NON/A_(ELEVATORS, FANS, DAMPERS) CENTRAL STATION ✓LpHONE '3-6-Z- 4 402, ACCOUNT 4 AUTOMATIC TIME DELAY OF ALARM SECONDS/MINUTES. NONE INSTALLED SYSTEM WIRING CONFORMS TO NFPA STANDARDS: YES NO PANEL KEY IN KNOX BOX: YES—NO OPERATING INST. AT PANEL: YES NO TEST RECORDS POSTED AT PANEL: YES NO I F mow r MASON COUNTY FIRE MARSHAL Mason County Bldg. III 426 W.Cedar P.O.Box 186 Shelton,Washington 98584 (206)427-9670 CORRECTION NOTICE _ OCCUPANT 4U K "� PERMIT# ( ADDRESS J�2 0 DATE f CONTACT i ' tA) N/t ' PHONE U CFM c( l{�l rN�s The following items do not comply with County Codes/O dinances.These must be corrected a d subsequently inspecte by the Mason Co my Fire Mars I. Its -9 DO NOT OCCUPY UNTIL ALL CORRECTIONS HAVE BEEN MADE AND AN OCCU- PANCY PERMIT HAS BEEN ISSUED. Following the correction of all violations contact the Mason County Fire Marshal for an inspection. Call 427-9670 Mon.-Fri.8:00-4:00 TO BE REMOVED BY INSPECTOR ONLY White-Occupant Yellow-Fire Marshal Pink-File i - S i r i t MASON COUNTY FIRE MARSHAL MASON COUNTY FIRE MARSHAL P 0• Box 186 \ , . Mason County Bldg. III 426 W. Cedar Shelton, WA 98584 P.O. Box 186 Shelton,Washington 985 (206)427 9670 ILE COPY CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION PERMIT NO. rA t561q_(>'1 10 MASON COUNTY FIRE PROTECTION SYSTEM PERMIT APPLICATION NOTE: This application must be completed and accompanied by a minimum of three (3) copies of plans, specifications and applicable calculations per Mason County Fire Protection Standards and brought to the office of the Mason County Fire Marshal. This is not a permit, and failure to submit all necessary information will cause a delay and/or rejection of your submittal. When a permit has been issued, you will be notified. PLEASE PRINT #1 OWNER �_ f.{tire 1 J V S PHONE L/ _-�x 7 SITE ADDRESS L-o ��7G P, c�.v {7,��j,��,-f h� FIRE DIST. CITY'5ilE-4tC„ Li,A STATE r,��i� ZIP `I Y� ' DIRECTIONS TO JOB SITE aw' i�. �,_ , I ,-, N", iL? L�f OWNER MAILING ADDRESS /L, p.2 '>Y T CITY ��, „, ���,� STATE ZIP ` LIEN/TITLE HOLDER �- ADDRESS CITY #2 CONTRACTOR�cRi;>,,,- ?AI S�r ��f CONTRACTOR REG # /; ��.5 »7,V',-_ ADDRESS,:-,,21 EXP. DATE CITY ,%�u,��: n STATE ZIP #3 PARCEL # A-L007_ LEGAL DESCRIPTION #4 BLDG. SQ. FT (EXISTING/PROPOSED) ��� 406E `/ 1ST FL / / 2ND / 3RD / BASEMENT / DECK / #BR #BATH GARAGE / CARPORT / ENCL ATTIC: Y N OTHER SQ FT USE OF BUILDING #5 DESCRIPTION OF WORK: SPRINKLER: WET DRY STANDPIPE: WET DRY AUTOMATIC FIRE jiL CORRIDOR SMOKES HOOD & DUCT DRY C ICAL WET CHEMICAL HALON NEW SYSTEM MODIFICATION NUMBER OF NEW DEVICES MONITORING STATION PHONE #6 DOES YOUR SUBMITTAL INCLUDE: 1. DIMENSIONS, SCALE, NORTH ARROW? YES K NO 2 . FLOOR PLAN AND CROSS SECTIONAL ELEVATION? YES�_NO_ 3 . ALL CONCEALED SPACES (LABELED COMBUSTIBLE AND NON-COMBUSTIBLE) ? YES_LNO_ 4 . ALL AREAS ON OPPOSITE SIDE OF NEW WALLS? YES L NO_ 5 . CUT SHEETS OR REFERENCES FOR ALL NEW DEVICES? YES ,,(� NO 6. LOCATION/DESCRIPTION OF ANY EXISTING DEVICES YES_-2�-_NO_ 7 . BATTERY CALCULATIONS FOR FIRE ALARM SYSTEMS? YES X NO_ 8. RISER/WIRING DIAGRAM FOR FIRE ALARM SYSTEMS? YES-2�_NO_ 9 . HYDRAULIC CALCULATIONS FOR SPRINKLER SYSTEMS? YES—NO— NOTE: WORK MAY PROCEED ONLY IN ACCORDANCE WITH A VALID FIRE PROTECTION SYSTEM PERMIT ISSUED BY THE MASON COUNTY FIRE MARSHAL. A VALID PERMIT AND AN APPROVED SET OF PLANS MUST BE ON THE JOB SITE DURING CONSTRUCTION AND MUST REMAIN THERE UNTIL A FINAL INSPECTION IS DONE BY THE MASON COUNTY FIRE MARSHAL. FAILURE TO OBTAIN A VALID PERMIT PRIOR TO WORKING ON A FIRE PROTECTION SYSTEM AND/OR FAILURE TO PROVIDE THESE PLANS AND PERMIT FOR THE MASON COUNTY FIRE MARSHAL MAY RESULT IN A CITATION AND FINE. OWNERS AFFIDAVIT I 'certify that I am exempt from the requirements of the Contrac- tors Registration Law RCW 18 .27, and am aware of the Mason County ordinance requirements for which this permit is issued and that all work will be done in conformance therewith. No changes will be made without first obtaining approval from the Mason County Fire Marshal. OWNER DATE CONTRACTORS AFFIDAVIT I certify that I am a currently registered contractor in the State of Washington and I am aware of the ordinance requirements regulating the work for which the permit is issued and all work done will be in conformance therewith. No changes will be made without first obtaining approval from the Mason County Fire Marshal. BY _ � /� "\ �<L 1�L✓J DATE / - C- �/ `� SECUIIITY & ELECTRIC �<.t L U4 �1riG E RIDI-A-N- e� SEPTEMBER 6, 1994 TO: MASON COUNTY FIRE DEPARTMENT s RE: APPLICATION FOR UPGRADE OF FIRE ALARM SYSTEM SITE: 520 WEST DAYTON AIRPORT RD. SHELTON, WA 98584 ELECTRIC CONTRACTORS: MERIDIAN SECURITY &ELECTRIC,INC. CONTRACTORS NUMBER: MERIDSE077NR FIRE SYSTEM PERMIT NUMBER: PROPERTY TAX NUMBER: FIRE DISTRICT: WATER DISTRICT: SCOPE OF WORK: EXISTING BUILDING: REPLACE EXISTING 52-04 FIRE PANEL WITH 52-07 PANEL. RECONNECT ALL EXISTING LOOPS &DEVICES TO NEW PANEL. TEST& CHECK PANEL. INSTALL 32 SMOKE DETECTORS IN EXISTING WAREHOUSE. NEW BUILDING: INSTALL 72 SMOKE DETECTORS (TWO PER BAY). INSTALL 10 HORN/STROBE AT ALL EXITS &BATHROOMS. INSTALL 10 PULL STATIONS AT ALL EXITS. INSTALL TWO DOOR RELEASES. 2218 Auburn Way North - Auburn, WA 98002 - (206) 351-5995 - Fax: (206) 351-5997 SILENT KNIGHT COMMERCIAL FIRE SYSTEMS M FIRE A RMS kv Model 5207 - Alarm ControlPanel FEATURES: • Eight zones, 6 Style A (class B) and 2 Style D �,,�. "� (class A). 8 Expander Zones are Style A (class B). Zones are interchangeable using the Model 7181 Zone Converter. • UL, FM, MEA (BSA), CFM Listed and Approved. • Event memory. • Fuseless design can reduce service time. • Field selectable, 12 or 24 VDC power supply. • Six amp current output at 12 volts,five amps at 24 volts. • Compatible with 2- and 4- wire smoke detectors as well as water flow and sounding devices. • Easy to install, program and service. • Four programmable (Style Y) supervised signal circuits, including steady, pulse and temporal. • Programmable smoke verification, pre alarm delay,and cross-zoning can minimizefalse alarms. Y • Four general purpose relays (Form C 24 volts at 5207 2.5 amps resistive). • Built-in approved digital communicator with UL required priorty reporting. • Flexible programming capabiities including up/ system problems, exist. If the 5207 encounters a fire or downloading and use of remote annunciator. No trouble condition, it sends a report to a central monitoring "desktop" programmer required. station (if applicable), and, typically, sounds an audible/ • Accu-Zone`s diagnostics facilitate local and visual warning in the local area. remote troubleshooting. The 5207's microprocessor constantly runs programs to • Individual zone Walk Test. check inputs and carry out other routine functions. If the program ever stops running,a watchdog circuit will detect DESCRIPTION: it and reset microprocessors to resume normal operations. The Silent Knight Model 5207 is an all-in-one fuseless The Model 5207 conducts an automatic self-test every 24 local fire evacuation control panel and digital hours—at a time you select—and sends a report to the communicator designed for applications requiring central station (if applicable). manual fire alarm, automatic fire alarm and water flow for sprinkler system supervision. The basic unit offers fire Other features of the system include English-language alarm for one to eight zones, expandable to 16 with the remote annunciation simplifying "Step Programming" of optional 5210 expansion module. It is compatible with custom options. Remote downloading of system both two-and four-wire smoke detectors. Compact,easy configurations can eliminate the expense of sending out a to install and service, it delivers the features you'd expect service technician for reprogramming. System provides a to find in fire systems costing much more. built-in fire drill procedure. The exclusive Accu-Zone feature measures and displays zone voltages,so you can During normal operation, the 5207 constantly checks set up and test the system without separate testing smoke and other sensing devices for fire conditions. It also equipment. Fuseless circuit board design eliminates one conducts system checks to determine if any troubles, or of the most likely causes for service calls. PROGRAMMING ANNUNCIATION The 5207 includes an annunciator inside the cabinet. Its six LEDs (for alarm, trouble, silenced, AC/low battery, event memory, time set/reporting) are visible without opening the cabinet. The annunciator allows for easy operation of all functions. It features dual seven-segment display and 14 uniquely assigned function keys. Keys are: ENTER, CLEAR, SILENCE, SHUNT and 0 9 used for ` ALARM RESET, CLEAR ALARM MEMORY, DIALER RESET, REQUEST DOWNLOAD, DISPLAY MEMORY, e B B B e B B B B B®B TEST,DISPLAY TROUBLES,SET DATE and SET TIME. f0000000000®® 0 0 o a o©o a o ® Remote annunciation is available through the Model 5230. ®©0 0 0 0 0 0 0 O Y© This four-wire, 16-zone remote annunciator is easy to ® operate. Its fourteen function keys can perform the same operations as the main system annunciator, including 5521 silencing,resetting,and displaying of alarms,troubles and alarm memory. Use of access codes prevents unwanted On-site programming is available through the optional tampering. In addition the Model 5230 can be used to Model Desktop Programmer or through any remote program all programmable options for both the local annunciator. control and digital communicator. Remote programming can be accomplished through the use of 5521 programmer and 5530 modem,or through the Features include LCD display, backlighting, English use of an IBM or compatible personal computer and the language annunciation. Model 5541 Downloading Software (requires the Model 5530 Downloading Modem). Up to seven 5230s can be attached to one 5207. Standby current draw per 5230 is 60 mA,alarm current is 120 mA. More than 60 programmable options are available for customizing system configurations and end-user features, including zone type (fire, panic, tamper, sprinkler, water, heat,cold, local);zone options(pre-alarm delayed,smoke verification delayed, zone disable); and zone location �TNu Kt.t. �t�. ."-' descriptions. Programmable dialer options include total f,R! Al ANM number of reporting attempts, Touch-Tone or rotary " -- ANNUNCIATOR dialing, one or two telephone lines. Several time delay features, including number of seconds to alarm in pre alarm, smoke delay conditions, number of hours before ff." left 12 0 60 m 0 loss of AC hours report, and 24-hour test time, can be programmed. ZONE EXPANSION 5230 The optional Model 5210 Zone Expander doubles the number of zones available to the 5207 from 8 to 16. The 5210 adds eight additional style A (class B)zones to the 5207, enabling use of both two- and four-wire smoke COMMUNICATIONS/REPORTING detectors. The 5207 is equipped with a UL listed digital dialer Voltage Ranges: Using 24-VDC power: 17.8-27.4 VDC. which has the ability to seize the telephone line(s)to report Using 12-VDC power: 8.5-11.8 VDC. alarms and troubles to a central station. It can supervise the telephone lines and activate a trouble-alert if a line ,,, failure is sustained for 45 seconds or longer. Other communications/reporting features include: Built-in ring •a'.', ���. C detector;re-try if communication failed;fail-to communicate output; one or two phone lines option; up to four phone 4 � f ` number capability(plus computer phone for downloading); Touch-Tone" and rotary compatible. The 5207 is compatible with all major reporting formats including SIA(security industry standard),SK,FSK,SK 4/ 5210 2,Radionics BFSK. Format selectable by account number. ARCHITECT/ENGINEER SPECIFICATIONS The contractor shall provide a complete electrically supervised alarm by specific zone(1-16).The relays shall remain energized fire alarm and communications system. The system shall until the panel is silence reset or the trouble condition is cleared, contain a fire alarm'•control/communicator and panel to unless"no-silence"is selected. supervise and operate heat and smoke detection devices,alarm signal devices, visual annunciators and an integral digital The control/communicator shall have an integral annunciator to communicator to transmit fire alarm and supervisory signals to indicate sequentially zones in alarm, zones in trouble, and a central station. The control/communicator shall be UL Listed system functions. LEDs shall augment the display to make clear or FM approved for use under NFPA 71,72A,7213,72C and 72D to an operator the system status. An integral touchpad shall be standards. It shall provide power and control for eight supervised provided to operate, set up, and interrogate the system. Vital detection zones,four supervised alarm signal circuits and a dual operations such as alarm silencing or reset shall be simple and digital communicator. The control/communicator shall be obvious to an operator. Authorization pass codes may or may expandable to sixteen supervised detection zones and shall be not be used. able to communicate to a central station in SIA,SK FSK1,SK 4/ 2 or Radionics BFSK formats. The control/communicator shall The control/communicator shall have the capability to supervise be Silent Knight Model 5207 or approved equal. two telephone lines, seize the phone line, and send the alarm signal on one or both lines without the addition of any more There shall be two Style D and six Style A detection zones. They equipment. It shall sound a local trouble signal if the telephone shall accommodate heat detectors, products of combustion service is interrupted for longer that 45 seconds and it shall detectors,manual pull stations,sprinkler flow switches and gate transmit a signal indicating the loss of phone line service to the valve supervisory switches intermixed as desired and permitted central station over the remaining phone line. A signal shall also by NFPA 71,72A,72B,72C,and 72D. Products of combustion be transmitted indicating the restoral of phone service. The detection may be either two- or four-wire and shall be cross control/communicator shall be able to report the loss of either listed by UL for use on the system. The detection zones shall be phone line without regard to which phone line failed first. If both programmed to(1)be cross zoned so that two individual zones lines fail, a local signal shall sound. must sense products of combustion, (2) automatically reset a detector to verify that smoke exists, (3)see a single detector in The control/communicator shall have the ability to send a test alarm—before the alarm is sounded and a signal is transmitted signal to the central station every 24 hours. The test signal shall to the central station. be able to be transmitted at a specific time of day or night by setting a program within the panel. There shall be four 1 amp supervised (Style Y) alarm signal circuits. They shall cause the bells/horns to ring steady/pulsing/ The alarm signals transmitted to the central station shall indicate temporal throughout the premises until reset or silenced. Two which of the eight zones is in alarm and which zones are in 1 amp outputs can be combined to provide one 2 amp output. trouble,depending on which format is used. Restoral from alarm or trouble shall also be transmitted by zone. The control/ The control shall be equipped with four auxiliary relays that shall communicator shall be capable of communicating to Silent be programmed to operate on(1)pre-alarm,(2)tamper alarm, Knight, Radionics or Ademco central station receivers. (3) special alarm, (4) fire alarm, (5) trouble, (6) no-silence, (7) TO RJJ,S TEL LINE•, TEL LINE 02 • . 1 Annun•,ulur •Ma• ♦PROGRAYMARLE,GENERAI. •Nan•.•y „u•.,y rocnpoa PNkP SE RELAYS(FORM G) a zoNE,NPvTs -- 51LINT KNIGHT 2 STYLE 0(CLASS A) c STYLE A(cuss e) MODEL 5207 su.Ewrsm skw crcl•n FIRE CONTROL AND COMMUNICATOR luo.usm-.wL �• '� .C,1•qt N0R11 J,YI ,•00(l JSJR OK lltlukF• rt,•f•SWnY •FYkI[AMMIMCY,O• �• ,LSD Y41t DC Ir....•.w, MODEL 5207 BLOCK DIAGRAM-TYPICAL INSTALLATION LIGHTNING PROTECTION: Silent Knight guarantees this product against lightning strikes! We will repair or replace the Silent Knight equipment, if necessary, should lightning disable it during the one-year warranty period. It's just another reason why Silent Knight has been a nationwide leader in electronic security for 25 years. SILENT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN 1-800-446-6444 or in Minnesota (612) 493-6435 KNIGHT FAX: (612) 493-6475 AMERICA FIRE SYSTEMS,. Form» 150376(Rev 6/94) PAGIL i. FEATURES. t .■ LOW staitdbycyrrent. :M.Twist 0041)0welling,bracket with tamper option. � ` rnia- `x Calif a DesignEd for�irci surface orelecfricsl State Fire �J bolt mounting, Marshal c. a Models available with built-in 85 dBA 7257-1209:103 Soil . ,., piezoelectric horn. ■ Insect-resistant screening (.020"/.508mm openings), a Isolated or integrated operation of MEA h : .. thermal,available. 1346-WSA ■ SEMS screws for easy wiring, (2400,2400TH) S ■ Unique optical sensing chamber. 1329.88-SA '.;• v" Superior signal-to-noise ratio. (AT,AIT) Approved v' Built-in signal processing. BSA 1: r 3,0%nominal sensitivity. (Formerl) ■ Removable cover for field cleaning �. Visible 4 r�4'O.inks" in standby. r, .,#,sealed a' gA flirt,insects ekod back �� S�rsor pressure, 6 - --- *Optional builrt�-i 1350F 570C thermal,--__... . yea warra t /242" ■Field metering of detector se) itivity.,, 4/8 11e n ., ■ Built-in test switch. ■3,000 fern air velocity. Photoe/ootrlc ftoke Detector ORDERING INFORMATION w/011tlonal born & 2412 Photoelectric Detector 12VDC,Direct Mount Tho mot 2412TH Photoelectric Detector 12VDC,with Integral 135OF Fixed Thermal 2412AT Photoelectric Detector, 12VDC,with Integral 135OF Fixed Thermal and 85d9A Horn GENERAL 2424 Photoelectric Detector;24VDC,for Control Panels The 400 Series''"photoelectric detectors 2424TH Photoelectric Detector,24VDC,with Integral 135OF Fixed Thermal are specifically designed to meet the 2424AT Photoelectric Detector,24VDC,with Integral 135OF Fixed Thermal and stringent performance requirements of in- 85dBA Horn dustrial and municipal fire detection/alarm 2424AIT Photoelectric Detector, 24VDC,with Isolated 135OF Fixed Thermal and 85dBA systems.The design of these detectors Horn emphasizes ease of installation and field AT?-71&0il End of Line Relay Module 12VDC maintenance.The AT/AiT models add A77-718-02 End of line Relay Module,24VDC built-in audible signaling and optional RA400 Remote Annunciator(LED) isolation of the thermal, MOD400 Feld Test Module T ; 4 i 1 .i412'TH 2412AT '. r 244 2a2aTH orT AIT.W" I'll Operating voltage:(+10%, —16%) 12VDC 12VDC 12VDC 24VDC 24VDC 24VDC Current consumption A.Standby(max.): 120µA 120MA 120µA 120MA 120µA 120jwA b.Alarm(max.): 77mA 77mA 51mA 41mA 41mA 43mA Reversed voltage(non-alarm): SmA 15mA Sensitivity Photo: 3.0%t.7FT 3.0%t,7FT 3,0%t.7FT 3,0%t.7FT 3.0%t,7FT 3.0%t.7FT Nominal Nominal Nominal Nominal Nominal Nominal Thermal: 1350F 135OF 1WF 135OF Relay contact retinas: Resistive or Inductive(SO%power factor)!veld Alarm contacts,. Form A:2.0A 0 30 VAC/DC Auxiliary contacts: Form C:2,0A a 30VAC/DC Weight- 0.7 Ib. 0.8A 0 110VDC, 1.0A 0 125VAC Un.- 5.0"h,65"difi. with mounting bracket Temperature: 32OF to 12013F(00C to 49°C) Humidity: 10%to 93%Relative Humidity Visual Alarm Indicator: Solid State Light-Emitting Diode 01"06'1994 10: 03 12063953365 TRIED INC PAGE 01 MQUNTIN Each 2412 and 2424 detector is supplied with a mounting bracket kit that permits the detector to be mounted: 1. Directly to a 3-1/2 inch or 4 inch octagonal, 1-1/2 Inch deep electrical box, (see Figure 1)or 2. To a 4 Inch square electrical box by using a plaster ring with the supplied mounting bracket kit. TMM�R i 71 AA Q T rrn - TO Y111�OET/C�IV►I�T/A�F7r[ff�1l�Ripilf�TlM, Figure 1. Flush Mounting of 2412/2424 Smoke Detector Figure 2. 2412/2424 Smoke Detector Mounting Bracket. on 3-1/2 Inch and 4 Inch Qctagonal 3ox. INSTAILLATIOU WIRiNG GUlD jWNEES NOTE: Refer to releasing device manufacturer's Installation Instruction for proper connections. All wiring must be Installed In compliance with the National Electrical Code and all applicable local codes and any special requirements of the authority having Jurisdiction, using the proper wire size. The conductors used to connect smoke de- tectors to control pagals and accessory devices should be color-coded to reduce the likelihood of wiring errors. Improper connections can prevent a system from responding properly In the event of a fire. For signal wiring (the wiring between interconnWed detectors), It is recommended that the wire be no smaller than AWG 18. However, the screws and clamping plate, in the base, can accommodate wire sizes up toAWG 12. The use of twisted pair wiring for the power (+ and—)loop is recommended to minimize the effects of electrical Interference, Smoke detectors and alarm system control panels have specificallons for allowable loop resistance. Consult the control panel manufacturer's specifications for the total icop resistance allowed for the particular model control panel being used before wiring the detector loops. NOTE: For system supervision—for terminals 1,2, 7, and 8, do not use looped wire under terminals, Break wire run to provide system supervision of connections. .ov+a* 4 + + FOAM CS MG I 1 ' �� s s + l i T-------------------------A-------"--------------------------1--- AMIlli-W AI!I{ii01 Figure 3. Wiring Diagram for 2412/2424 Series Smoke Detector umod with 4-Wire Control Panel. NOTE: Contacts are shown in stand-by mode and will transfer In alarm conditlon. Wire connections are made by stripping about 3/8 Inch of insulation from the end of the wire, sliding the bare end of the wire under the clamping plate, and tightening the clamping plate screw. TAMPER-AE$1STANCL This detector Includes a tamper-resistant feature that prevents removal of the detector without the use of a tool. To make the detector tamper-resistant, break off the smaller tab at the scribed line on the Tamper Resistant Tab, on the detector mounting bracket (see Figure 2). then Install the detector. To remove the detector from the bracket once it has been made tamper-resistant, use a small screwdriver to depress the tamper-resistant tab located in the slot on the mounting bracket and turn the detector counterclockwise for removal. D400-06-00 2 166 286-02 F 09/06/11994 1C1: 03 12063953365 TRIED INC PAGE 02 INSTALLATION WARNING: REMOVE POWER FROM INITIATING-DEVICE CIRCUITS BEFORE INSTALLING DETECTORS. 1. Wire detector per Installation guidelines. 2. Line up arrows on the detector with arrows on the mounting bracket. 1. 3. Turn the detector clockwise until the detector cfli*s into place. 4. After all detectors have been Installed, apply power to the control unit. S. Test the detector as described under TESTING, 6. Reset the detector at the System Control Panel 7. Notify the proper authorities that the system is in operation. CAUTION - Dust covers provide limited protection against airt,ome dust particles during shipping. Dust covers MUST be removed before the smoke detectors can sense smoke. Remove sensors before beginning heavy remodeling or construction. THTM Before testing, notify the proper authorities that the smoke detector system Is undergoing maintenance, and therefore the system will temporarily be out of service. Disable the zone or system undergoing maintenance to prevent unwanted alarms. 14. 1 Detectors must be tested after installation and following periodic maintenance.The 2412 and 2424 may be tested as fol- lows: Before testing the detector, look for the presence of the fiiashing LED. If it does not flash, power has been lost to the de- tector(check the wiring), or It is defective (return for repair). A.RECESSED TEST SWITCH 1. A test switch Is located on the detector housing (see Figure 4). 2. Push and hold the recessed teat switch with a 0.1 Inch maximum diameter tool. 3. The LED on the detector should light within 5 seconds. B. CALIBRATED TEST CARD (Model R59-18-00) 1. Remove the detector cover by placing a small-bladed screwdriver in the aide slot of the detector cover,twisting slightly until the cover can be turned counterclockwise for removal. IN 2. Insert the NO ALARM end of the test card fully into the test slot (see Figure 5), then slide It counterclockwise until it stops. 3. The detector should not alarm after 20 seconds. 4. Remove the test card by sliding It clockwise before removing, then Insert the ALARM end. 5. The LED should latch on within 20 seconds, Indicating alarm and annunciating the panel. 6. Put the cover back by gently rotating h clockwiso until it locks In place. C.TEST MODULE (System Sensor Model No. MOD400R) The MOD40OR Is used with an analog or digital vof�meter to check the detector sensitivity as described in the MOD4008 manual. LCOT I wi AM13YJ-W Figure 4.Tbp and Side Vies Showing Position of Recessed Test Switch. D. AEROSOL GENERATOR (Gemini 601) Set the generator to represent 4%/Ft. to 5%/Ft. obscuration as described in the Gemini 501 manual. Using the bowl shaped applicator, apply aerosol until unit alarms. D400.06-00 3 156.286.02 _ whe-eJock FRIES rAT MULTITONE ELECTRONIC SIGNALS heelock's New MT and IAT Strobe alarm signals offer a choice om (8) nationally and internationally recognized alerting sounds as = ascribed below. The signals feature a designer appearance that liminates all visible mounting hardware. F t I r � E SERIES SERIES MT MT WITH 108 BACKBOX EATURES a One alarm appliance to meet most of your signaling a MT Strobe models available with 117 candela ratings for requirements. Switch selective for Horn, Bell, March independent or single input activations (ADA compliant). Time Horn, Code-3 Horn, Code-3 Tone, Slow Whoop, u Polarized inputs for compatibility with standard reverse Siren or Hi/Lo Tone. polarity typo supervision of circuit wiring by an alarm o Code-3 Horn and Tone incorporate temporal pattern panel. recommended by ANSI/NFPA/ISO for standard a Low cost installation via standard electrical boxes (4" sq. emergency evacuation signaling. or 2-gang for easy retrofit). No additional trimplate o Field selective sound output levels (2); either required for flush mounting. In/Out screw terminals. STANDARD dBA or HIGH dBA up to 106 dBA a No visible mounting hardware. Indoor and outdoor 10 feet (peak meter response). surface mount option. e Low power consumption and limited in-rush current. ■ RFI suppression to ensure compatibility with sensitive n 12 VDC and 24 VDC operating voltage settings alarm detection circuits. (MT Strobe versions factory set). o U.L. Listed for Fire Protective Service. RM TONES ALARM TUNES ©WARNING:MULTITONE STROBE SIGNALS MUST BE FIELD SET FOR THE DESIRED dBA SOUND OUTPUT LEVEL AND TONE PATTERN DESCRIPTION At ARM TONE BEFORE THEY ARE INSTALLED THIS IS DONE By PRNG A PER HORN BROADBAND HORN (Continuous) AND ADJUSTING ALFO RSITIO POSIT ON SWITCH INPLIIG BELL 1560 Hz MODULATED 0.07 sec. ON/Re teat INACCORDANCEINCORRECT S WITH THESE INSTRUCTIONS. IMPROPER ( { � _ INC(IIRRECT SETTINGS Wlll RFSULT IN IAIPROPER MARCH TIME HORN HORN (0.25 sec. ON/0.25 sec. OFF/Repeat) PERFORMANCE AND MAY DAMAGE THE PRODUCT, CODE-3 HORN HORN (ANSI S3.41 Temporal Pattern) SFR OUS0ULD INJURYEORLDEATH TOPERTY YOU AN OR DAMAGE CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) oTHEf1s. SLOW WHOOP 500-1200 Hz SWEEP 4.0 sec. ON/0.5 sec. OFF/Repeat) SIREN 600-1200 Hz SWEEP 1.0 sec./Repeat) HPLO 1000/800 Hz (0.25 sec. ON/ALTERNATE) RDERING INFORMATION AND SPECIFICATIONS ABLE 1: dBA AND CURRENT RATINGS FOR MULTITONE SIGNALS MULTITONE SIGNAL Typical Anechoict Rated Reverberant dBA' Input Current, Input Current, dBA at 10 Feel At 10 Feet Per UL 464 Tone AMPS @ 24 VDC AMPS 12 VDC At Nominal At Minimum At Nominal Input Voltage Input Voltage Input Voltage HI STD HI STD HI STD HI STD HI STD HORN 0.040 0.023 0.100 0.020 101 95 88 82 91 85 BELL 0.014 0.012 0.031 0.010 94 89 82 75 85 79 MARCH TIME HORN 0.040 0.023 0.100 0.020 101 95 85 79 88 82 CODE-3 HORN 0 040 0.023 0.100 0.020 101 95 85 75 85 79 CODE-3 TONE 0.028 0.017 0.060 0,015 _97 _ 92 79 75 82 75 SLOW WHOOP 1 0.048 0.026 0.100 0.025 101 96 88 82 88 82 SIREN 0.0:;6 0.023 0.082 0.020 100 95 85 82 88 82 HI/LO 0.020 0.014 0.044 0.012 95 90 1 82 79 85 79 Add 25%more Input current when operating the unit at maximum input voltage(15.6 VDC for 12 VDC models, 31 VDC for 24 VDC models). Anechoic dBA Is measured on axis In a non-reflective(free field)test room using last meter response.For peak dBA(measured with peak meter response), add 5 dBA to typical anechoic values shown in Table 1. Reverberant dBA is a minimum UL rating based on sound power measurements in a reverberant test room. 5 I• ; California r State Fire Marshal S711 7150-075:103 Approved OG.5A5 latest advancement in manual alarm able;the back plate is of 16 ga. steel. It will stations. Its construction is of a space-age operate with or without a break glass tube. plastic,Lexan,which is virtually indestruct- Switch Rated 3 Amps C, 30VAC/30VDC. ORDERING INFORMATION • Model Description BG-10 Standard Unit, Dual Action, Break Glass or Non-break Glass,Terminal Block BG-10A As above, but with an extra switch to provide annunciator contacts, N.O. Fire-life BG-10 BG-10T The Standard Unit with Key Test Feature BG-10P The Standard Unit Set for Pre-signal Operation Non Coded Manual BG-10L A Standard Unit with Key Locking Feature instead of the normal Allen Key type locking Alarm Station BG-10WP Standard Unit, Dual Action with Terminal Block,Weatherproof BG-10SP Standard Unit,Spanish version. Fuego printed on cover. GENERAL BG TR Trim Ring for BG-10 Series The"A"option is available will)the"T"or"U..However,the"T"and"L"models may not be combined The Fire-Lite Model BG-10 Non-Coded, Note:Can be mourled on single gang or 4"square box with BG TR trim ring. Dual Action, Manual Station is the very SB-10 Surface Back Box for all BG-10 Models WP-10 Weatherproof Surface Back Box for BG-10 WP California IJL State Fire Marshal S711 q "1)I 7150-075:148 it, FEATURES _ ■ Sturdy metal construction. ■ Drawing of flames on cover helps com- municate purpose of this device to people who do not read English words. ■ Operation does not require replace- Its Designed to prevent false alarms when ment of parts, bumped, shaken or jarred. p^ ORDERING INFORMATION Fire-life Q Model Description BG-8 Manual Fire Alarm Pull Station. Single action. Normally-open contact. Manual fire Alarm BG-8SP Standard Unit,Spanish version. Fuego printed on cover. BG-2R Surface Mounting Back-Box for BG-8 Series Stations. One end tapped for Station th" conduit.Color is Red. ■ Helps eliminate unwanted alarms. ■ Optional horn powered by 9 VDC battery. UL IN CASE ' i1 ■ Weatherproof option. FIRE�} SAMGLASS ■ Flush and surface versions. PULL FIRE ALARM i, iSS ORDERING INFORMATION Model Description Replacement Parts ltr ni qt � _..s The Stopper II STI 1100 Stopper II with Horn-Flush STI 4001 Replacement Glass for 4100 STI 1130 Stopper II with Horn-Surface STI 1200 Stopper II no Horn-Flush STI 6001 Replacement Glass for 6100 STI 1230 Stopper II no Horn-Surface STI Series STI 1250 Weather Stopper II-Flush STI 3100 Conduit Spacer-Surface STI 3150 Weather Stopper II -Surface Mount Protective Covers STI 4100 Stopper"G", Large Break Glass Cover STI 3002 Weather Gasket FEATURES STI 6100 Stopper"G•',Standard Break ■Aesthetically pleasing and easily installed. Glass Cover STI 3003 Conduit Gasket TABLE 5- I: CURRENT LOAD WORKSHEET DEVICE OF DEVICES (TIMES) CURRENT PER = TOTAL TOTAL (MAX.ALLOWED) DEVICE 1 STANDBY ALARM CURRENT CURRENT 5207 1 X Standby: 120 mA = 120 mA X Alarm: mA*2 = ie-,,G mA 5210 Zone Expander 1 X 40 mA = 40 mA 40 mA 5230 Annunciator X Standby: 60 mA = it,�, mA (7 max.) X Alarm: 120 mA - i mA i 4180 Status Display Module 1 X Standby: 20 mA = X Alarm: 140 mA 5220 Series Type Master Box 1 X 15 mA = iri> -4900 5255 On-Site Printer 1 X 40 mA = 400" 46waA (no longer available) 5260 Printer Interface 1 X 25 mA = "WivA 20" 5521 Desk Top Programmer 1 X 30 mA 36NMA SMOKE DETECTORS (Refer to device manual for (See section 5.3 for current ratings.) max. # per loop.) X Standby: mA mA X Alarm: mA = 2 7 7 mA X Standby: mA = mA X Alarm mA = mA X Standby: mA = mA X Alarm mA = mA SOUNDING DEVICES (4 max.) (Refer to device manual for current ratings.)*3 X Alarm: mA = 5-7 4,: mA X Alarm: mA = mA X Alarm: mA = mA X Alarm: mA = mA ADDITIONAL DEVICES NOT LISTED ABOVE X Standby: mA = mA X Alarm: mA = mA X Standby: mA = mA X Alarm: mA = mA X Standby: mA = mA X Alarm: mA = mA J-1i 3*A ii lb jA TOTAL CURRENT RATINGS OF ALL DEVICES IN SYSTEM STANDBY ALARM *NOTE 1: If only one current rating is listed, the draw for that device is the same whether the system is in alarm or standby condition. The exception is the sounding devices. See NOTE 3. *NOTE 2: The alarm current draw for the 5207 ControllCommunicator will vary from approximately 20 mA to 700 mA, depending on how the system is configured. You will need to measure the current draw for your installation and write the amount in the space on the worksheet. Connect an AC amp meter in series with one of the batteries. Disconnect the AC power source. Put the panel in alarm. The meter will indicate the alarm current. *NOTE 3: Sounding devices are rated for alarm current only. Standby current is 0 mA. Revised 3/93 14 ' - - TABLE 5 II: MAXIMUM BATTERY STANDBY LOAD1 a • RECHARGEABLE BATTERY MAXIMUM LOAD FOR MAXIMUM LOAD FOR SIZE 24 HOURS OF STANDBY TIME AND NFPA 72B AND 72C 5 MINUTES OF ALARM TIME (60 HOURS STANDBY, 5 MINUTES ALARM) 6.5 AH 240 mA N/A 10 AH 370 mA 150 mA 17 AH 675 mA 275 mA TABLE 5- III: BATTERY CALCULATIONS You can use this table to determine the battery amp hour rating needed for your installation. TOTAL STANDBY CURRENT TOTAL ALARM CURRENT ....... .... .......................... ..................... A Total supervisory current from Table 5-I. B Number of standby hours (24 for NFPA 71 and 72, Chapters 6 and 9; 60 for NFPA 72, Chapters 7-8) C Multiply Lines A and B `'V 4 D Total alarm current from Table 5-1. tj E Alarm sounding period in hours. (For example, 5 minutes = .084 hours.) C < F Multiply Lines D and E 5 as G Add Lines C and F H Multiply Line G by 1.2 (Total ampere/hours required*) —1 ( � *Use next size battery with capacity greater than required. 1 Tables 5-1 and 5-II are derived from the following formula: C All l WHERE: H = Standby hours. H = J x 0.65 AH = Ampere-hour rating of battery. I = Standby current. 0.65 = A constant used to derate the battery to assure a 5-year life. 15 Revised 3/93 MASON COUNTY FIRE MARSHAL Mason County Bldg. III 426 W.Cedar P.O. Box 186 Shelton,Washington 98584 (206)427-9670 a� Go 10 41f4- CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION AUTOMATIC FIRE ALARM SYSTEM ACCEPTANCE TEST REPORT ADDRESS____________ _ -OCCUPANT PHONE , USE------WA ------- --- ------------------------ 1 - 351-5 � FIRE ALARM CONTRACTOR � PHONEdam, CONTACT— INSTALLER s� PLANS & PERMIT ON SITE Y S NO PERMIT # CONTROL PANEL MFR _— MODEL #_ INITIATING CIRCUITS NO. OF SIGNAL CIRCUITS BATTERY VOLTAGE VOLTS CHG.CIRCUIT VOLTAGE VOLTS BATTERY VOLTAGE UNDER FULL LOAD VOLTS(SIGNALS OPERATING) W l 04P TROUBLE SIGNAL WITH AC POWER OFF: YES NO ZdL16- SYSTEM OPERATES ON STANDBY POWER: YES—NO—N/A 5� ALL SIGNALS OPERATE ON AC POWER: YES—NO—N/A GSD ALL SIGNALS OPERATE ON STANDBY POWER: YES—NO—N/A ALL CIRCUITS CHECKED FOR ELECTRICAL SUPERVISION: YES—NO—N/A \ Z-j CONTROL PANEL CHECKS MADE PER NFPA& MFTRS. INSTRUCTIONS: YES-NO-N/A ' Re ) - 55 ALL AUXILIARY EQUIPMENT OPERATES: YES—NO_N/A—(ELEVATORS, FANS, DAMPERS) Z_g CENTRAL STATION-AMA5 PHONE II � ACCOUNT, AUTOMATIC TIME DELAY OF ALARM SECONDS/MINUTES. NONE INSTALLED SYSTEM WIRING CONFORMS TO NFPA STANDARDS: YES NO PANEL KEY IN KNOX BOX: YES NO OPERATING INST. AT PANEL: YES NO TEST RECORDS POSTED AT PANEL: YES NO DeA15-jtobes ' ---. oun ? e EQUIPMENT TESTED # �.t F TYPE OF EQUIPMENT #UNITS IN BLDG. # UNITS TESTED COMMENTS AUDIBLE DEVICES ------------ ------------ — ------- VISUALDEVICES TROUBLE INDICATORS J HEAT DETECTORS 1 ------------ ------------ -------- t A.F.S. SUPV. SWITCHES ----_--_ 2 ------------ ------------ 7, ./ SMOKE DETECTORS w 6' ------- MANUAL PULL STATIONS —� f-4L __LS4(4r ------------ -------- / WATER FLOW SWITCHES j ------------ ------------ -------- �-- GENERATOR STARTS ---_--__ ------------ ------------ VENTILATION CONTROLS -J ------------ ------------ -------- l CENTRAL STATION t'wu1S ✓ F.D MONITORING ------------ ------------ -------- ANNUNCIATORS �/ ------------ ------------ -------- b ELEVATOR RE ------------ ------------ -------- DOOR RE LEAS 7) (7 ------------ ------------ -------- FIRE DAMPERS ------------ ------------ -------- PHONE JACKS ------------ ------------ -------- AUTO DOOR LOCKS AUTO DOOR RELEASES ------------ ------------ -------- OTHER THIS IS TO CERTIFY THAT THIS AUTOMATIC FIRE ALARM SYSTEM HAS BEEN INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT, IS CONSISTENT WITH NFPA FIRE ALARM STANDARDS,AND THAT ALL CORRECTIONS HAVE BEEN MADE. G� (/ A. SIGNATURE OF OWNER OR REPRESENTATIVE: DATE B. FIRE ALARM COMPANY: PHONE: C. SIGNATURE OF FIRE ALARM CO. REP: DATE 5 ✓ D. FIRE ALARM CONTRACTOR LICENSE #: (/S _ / PROBLEMS FOUND:_ YV� ------------- JCORRECTIONS MADE: ------------------------------------------ V P S _ �� qol (206) 357-5197 Security Moldings, Inc. (800) 395-2527 y�0 ' 17533 . 15th Avenue N.E., Seattle, WA 95155 INSTA.LI ATION ACCOUNT SET-UP FORM Code:: Description: Location: Audible. Response. VLt B ice tuLL STATIONS Srnake Code:; Description: Location: v-eAudible: S��vC�u�a.-�..sine t�J ii STft'T i otJS Code:: Description: Location: Audible: -zone Response- RC 5�-rvck\iPu sNne \Aeo-ar 1b- ek- Code:: Description: Location: Audible: ZcN Res onse: FAQ.E (-SD ShopPv1� 5TRT1c�A/5 I-\e�� Cade:: 1escription: Location: W(+V_jr-kA6 sE -a Audible: 2 o N c- r1 Response: 169,E Code:: Description: Location: WADE�{04 S,(y\o)e'v- Audible: Z OW C Res onse: kc Code:: Description: Location: S,4 Qvcatvtza� Shd� Smo"Ke- be.+, Audible: Zow Ic lies onse: Vt PC Code:: Description: Location: W(AR� 3 tv!\w5p- �1 \1 -S-TA T I ONS Audible: 2 atjE l0 Res onse: Code:: Description: Location: U,� QE1�euse \\ Sko; � aws Audible: Z o m C \1 Response: XRC Code:. Description: Location: GO�. �au:e r Ste;PPty - oZ �`..A',ble: zoNti i Res onse: T `Sg E: RC i_as Description: Location: Au'. Po--=e-lr' Audible: Z orate \3 Response: TR008tZ c Loin t3RTcE J Code:: Description Location: Audible: -©'�e t Response- k P .c 0%20' Code:: Description. — Location: Audible: Za-ne Response: 6L.0 Code:: Description: Location.: Audible: Response: Code:: Description: Location: Audible: Res onse: Code:: Description: Location: ` svt �--- Audible: ices onse: /o EMERGENCY CALL UST 1. PHONE #: 2• PHON #: 3. PHONE #: 4. PHONE #: 5. PHONE #: PHONE #: PHONE #: 8• PHONE #: Start date for Police and Fire Dispatch: t MASON COUNTY FIRE MARSHAL Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,Washington 98584 (206)427-9670 CORRECTION NOTICE OCCUPANT A PERMIT# 4 15 ADDRESS DATE D i CONTACT PHONE The following items do not comply with County Codes/Ordinances.These must be corrected . and subsequently inspected by the Mason County Fire Marshal. 4 GJ 1 �S ADO NOT OCCUPY UNTIL ALL CORRECTIONS HAVE BEEN MADE AND AN OCCU- A Y PERMIT HAS BEEN ISSUED. Following the correction of all violations contact the Mason County Fire Marshal for an inspection. Call 427-9670 Mon.-Fri. 8:00-4:00 TO BE REMOVED BY INSPECTOR ONLY White-Occupant Yellow-Fire Marshal Pink-File 10/19/2004 15:59 FAX 3604279438 SHELTON FIRE \-> ` 001 A 5 SMITH FIRE SYSTEMS, INC. DATE 10/5/04 1106 54TH AVE. E. PH: (253) 926-1880 JOB ## 4435 TACOMA, WA 98424 FAX: (253) 926-2350 CONFIDENCE TESTING - S :=- � ;► FIRE ALARM _1 a NAME AERO CONTROLS, INC-SHELTON ADDRESS 520 W DAYTON AIRPORT RD, SHELTON, WA CONTACT AL CAREY PHONE _ (253) 269-3144 NAME OF TESTER CERTIFICATION NO. DATE OF INSPECTION October 5, 2004 TYPE OF INSPECTION ANNUAL CONTROL PANEL MANUFACTURER SILENT KNIGHT MODEL NO. 5207 NUMBER OF INITIATING CIRCUITS 149 NO. OF SIGNAL CIRCUITS 20 BATTERY VOLTAGE 6. 6 VOLTS CHARGE CIRCUIT VOLTAGE 2� 2-2! VOLTS BATTERY VOLTAGE UNDER FULL LOAD �J L g VOLTS (SIGNALS OPERATING) 1. Trouble signal with AC power off YES Z NO ❑ N/A ❑ 2. System operates satisfactory on standby power YES D"- NO ❑ N/A ❑ 3. All signals operate on AC power YES �� NO ❑ N/A ❑ 4. Have all alarm notification appliances been checked for proper operation? YES ®� NO ❑ N/A ❑ 5. All circuits checked for electrical supervision YES NO ❑ N/A ❑ 6. Control panel checks made per manufacturer's instructions YES NO ❑ NIA ❑ 7 All auxiliary equipment operates (Elevators, fans, dampers) YES ❑ NO ❑ N/A Q� 8. Central station or remote connection YES NO ❑ NIA ❑ Name of Monitoring Company ALARM CENTER 9. Key to panel available YES F7"'- NO ❑ N/A ❑ 10. Operating instructions at panel? YES Ft""- NO ❑ N/A ❑ 1 1. Service Label or Tag (SFC Appendix III-B) YES L'3 NO ❑ N/A ❑ 1 ' t EQUIPMENT TESTED TYPE OF EQUIPMENT NUMBERS OF SATISFACTORY NO. OF UNITS UNITS TESTED YES NO N/A IN BUILDING Bells, Horns, Chimes 20 20 Voice Alarm Speakers Visual Alarm Device 19 19 Trouble Indicators 2 ✓ 2 Super. Switch (Auto. Spr.) 0 (/ 0 Auto Spr. Flow Switches 0 0 Smoke Detector(s) 113 113 Heat Detector(s) 21 21 Manual Pull Stations 15 15 Ventilation Controls Operate 0 / 0 Central Station 1 ✓ 0 Annunciators 1 ✓ 1 Elevator Call Down 0 / 0 Fire Damper/Smoke Dampers 0 t/ 0 Phone Jacks 2 ✓ 2 Auto. Door Unlocks - (Failsafe) 0 0 Auto. Door Release 3 t/ 3 Other 0 0 PROBLEMS FOUND: CORRECTIONS MADE: r I DATE CORRECTED �U_cJ� —v BY THIS IS TO CERTIFY THAT THE FIRE ALARM SYSTEM HAS BEEN PROPERLY TESTED AND INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT. SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma WA 98424 (253)926-1880 0 1 > Slgnatu ns ct r Print Name Date i Signatur i(Tuner or Representative Print Name Oat 2 FIRE SYSTEMS WEST' INC. _ Seattle Office _ Portland Office 219 Frontage Road N., Suite B 600 S.E. Maritime Ave., Suite 300 Pacific, Washington 98047 Vancouver, Washington 98661 (253) 833-1248 (360) 693-9906 HOOD SYSTEMS REPORT Occupied as: Ar.4i �oi✓J/QoGs ,.Z-,✓G. Building Owner: Phone:_) Address: W, 576 bA YTOkl Pf OAWr / City: Sdfc.roA' State: ad —Zip Code: 9 FSY) Date of Inspection: &S ,'1,4A®_ Type of Inspection: FAAnnual Semi-Annual Acceptance Make of System: TuAD - eJ{ Size: !!�x PC5"U Fuel Shut-off: DGas (g Electrical 1. Cylinder's pressure gauge or weight is in acceptable range? ..............................® Yes ❑ No N/A 2. Are all lead and seals intact?................................................................................® Yes ❑ No ❑ N/A 3. Are there any visible signs that system has been fired or tampered with?.....................................................................................................R Yes 0 No N/A 4. All piping and conduit secured with proper hangers and brackets? ..............................................................................................................[A Yes No ❑ N/A 5. Positioning of all nozzles okay? ..........................................................................© Yes D No ❑ N/A 6. Self-closing caps? ................................................................................................❑ Yes No ❑ N/A 7. Replaced all protective covers on nozzles?..........................................................El Yes M No ❑ N/A 8. Fusible links replaced?.........................................................................................® Yes ❑ No N/A 9. Tested system from thermal link for proper operation?.......................................[R Yes ❑ No M N/A 10. Tested system from manual remote (Inspectors Test) for proper operation?............................................................................................0 Yes D No ❑ N/A 11. Automatic shutdown of fuel/power operated properly (micro-switch)?..............© Yes ❑ No ❑ N/A 12. Is system visible and free from obstructions?......................................................0 Yes ❑ No ❑ N/A 13. Is inspection service tag on system?....................................................................EO Yes ❑ No ❑ N/A 14. Are all cooking surfaces protected?.....................................................................0 Yes El No ® N/A 15. Are proper hand portable extinguishers properly serviced? ................................M Yes ❑ No ❑ N/A Problems found: Corrections made: 6.0*57 lit/r'N A/£A) Technician: Certification:_G�3�1� �nc�r� ��Trc Owner/Res entative• Date: O�O S/a 3 c:Uioodrep 10/24/97 FIRE SYSTEMS WEST, INC. VN&I Seattle Office _ Portland Office 219 Frontage Road N., Suite B 600 S.E. Maritime Ave., Suite 300 Pacific, Washington 98047 Vancouver, Washington 98661 (253) 833-1248 (360) 693-9906 HOOD SYSTEMS REPORT Occupied as: A,,,p C 1S Building Owner: pp Phone:! ) Address: LA ) Qa;�t,� �r� Oct I j city: State: LA-J-4 Zip Code: a Date of Inspection: Type of Inspection: Annual Semi-Annual Acceptance Make of System: C Size: # -SZ► l y QC Fuel Shut-off: Gas Electrical IF 0444Ao 1. Cylinder's pressure gauge or weight is in acceptable range? ............................ Yes ❑ No N/A 2. Are all lead and seals intact?................................................................................[0 Yes F-1 No N/A 3. Are there any visible signs that system has been fired or tampered with?.....................................................................................................❑ Yes J2�,No N/A 4. All piping and conduit secured with proper hangers and brackets? ..............................................................................................................tg� Yes No ❑ N/A 5. Positioning of all nozzles okay? ........................................................................... Yes No N/A 6. Self-closing caps? ................................................................................................❑ Yes No g' N/A 7. Replaced all protective covers on nozzles?..........................................................0 Yes No N/A 8. Fusible links replaced?....................................... ...............E] Yes �Z No E] N/A 9. Tested system from thermal link for proper operation?.....................................-.K Yes ❑ No N/A 10. Tested system from manual remote (Inspectors Test) for proper operation?...........................................................................................:� Yes [:] No E] N/A 11. Automatic shutdown of fuel/power operated properly (micro-switch)?..............0 Yes ❑ No ❑ N/A 12. Is system visible and free from obstructions?.....................................................� Yes No ❑ N/A 13. Is inspection service tag on system?..................................................................:g Yes ❑ No ❑ N/A 14. Are all cooking surfaces protected?.....................................................................❑ Yes 11 No jgN/A 15. Are proper hand portable extinguishers properly serviced? .............................. Yes ❑ No ❑ N/A Problems found: Corrections made: Technician: Certification: 5-0C-M'0 Owner/Representative: Date: 03/( 1/01 cAhoodrep 10/24/97 Fire Systems West, Inc. 219 Frontage Road North,Suite B • Pacific, Washington 98047 • (253) 833-1248 LETTER OF TRANSMITTAL DATE JOB NO TO: SHELTON FIRE DEPARTMENT ATTENTION P.O. BOX 1277 RE AERO CONTROLS SHELTON, WA 98584 W. 520 DAYTON AIRPORT RD. SHELTON, WA 98584 WE ARE SENDING YOU: ®Attached ❑Under separate cover via the following items: ❑ Shop Drawings ❑ Prints ❑ Plans ❑Samples ❑ Specification ❑ Copy of letter ❑ Change order ❑ 1 HOOD TEST REPORT THESE ARE BEING TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval E For your use ❑ Approved as noted ❑ Submit copies for distribution ❑As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ ❑ For bids due ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO File SIGNED: Monica Havens, Admin. Asst. •: FIRE SYSTEMS WEST, INC. Seattle Office _ Portland Office 219 Frontage Road N., Suite B 600 S.E. Maritime Ave., Suite 300 Pacific, Washington 98047 Vancouver, Washington 98661 (253) 833-1248 (360) 693-9906 U Y C�O� g YSTEMS REPORT Occupied as: AoP arAi-YU1 S Building Owner: Phone: (Jk) (/a 9 5_9y4 Address: —itwt ar 4 Kcl City: 'a State: J�Aj )d Zip Code: Date of Inspection:_ f Type of Inspection: Annual Semi-Annual Acceptance Make of System:��y vn /xc f'r1�c) Mize: '/-SD I b Fuel Shut-off. Gas Electrical 1. Cylinder's pressure gauge or weight is in acceptable range? .............................JK Yes ❑ No ❑ N/A 2. Are all lead and seals intact?..............................................................................� Yes No ❑ N/A 3. Are there any visible signs that system has been fired or tamperedwith?.....................................................................................................❑ Yes 0 No N/A 4. All piping and conduit secured with proper hangers and brackets? ............................................................................................................. Yes No N/A 5. Positioning of all nozzles okay? ........................................................................� Yes ❑ No 0.N/A 6. Self-closing caps?................................................................................................[:] Yes No X N/A 7. Replaced all protective covers on nozzles?.........................................................ice Yes No N/A 8. Fusible links replaced?.........................................................................................❑ Yes X No N/A 9. Tested system from thermal link for proper operation?.......................................X Yes ❑ No N/A 10. Tested system from manual remote (Inspectors Test) forproper operation?........................................................................................... Yes E] No F� N/A 11. Automatic shutdown of fuel/power operated properly (micro-switch)?.............% Yes No ❑ N/A 12. Is system visible and free from obstructions?...................................................... Yes ❑ No N/A 13. Is inspection service tag on system?.................................................................... Yes No ❑ N/A 14. Are all cooking surfaces protected?.....................................................................❑ Yes ❑ No 5d N/A 15. Are proper hand portable extinguishers properly serviced? ............................... Yes ❑ No N/A Problems found: ALU 42- Corrections made: 1---)6JU-e- Technician: Certification: �3d � Owner/Representative: Date:_ 3' 2 clhoodrep 10/27/99 Fire Systems T rest 219 Frontage Road, North, Suite B • Pacific; Washington 98047 ! Phone 206-833-1248 HOOD SYSTEMS REPORT Occupied as 04 �O►� S LAIC. Building Owner Sc A*A_r Phone Address JU. .�,Z a � %I A40n/+Ja.City ►�,Q�.�r, Zip Code 98sjBy Date of inspection e Type of inspection: Annual Se annual ✓ Acceptance Make of system Siz uel Shut-off: Gas Elec.---;,)),+ _sn 1. Checked pressure gauge indicator in operable range Yes ✓No 1�r/A 2. All lead and seals are intact Yeses No N/A_ 3. There are no visible signs that system has been fired or been tampered with Yes ✓ No_N/A 4. All piping and conduit immobilized with proper hangers and brackets Yes ✓No_N/A_ 5. Positioning of all nozzles okay Yes ✓ No_N/A 6. Self-closing caps Yes_No_N/A__j,, 7. Replaced all protective covers on nozzles Yes_No_N/A__Ie, 8. Fused links replaced CID -G)062 Ytftcl- f -(�� Yes ✓No_N/A 9. Tested system operation from terminal link for proper operation Yes No_N/A_ 10. Tested system operation with manual remote (inspect. test) for proper operation Yes ✓No_N/A_ 11. Tested system operation and proper operation of micro-switch Yes ✓No_N/A_ 12. System is now visible and free from obstructions Yes ✓No_N/A_ 13. Inspection and service tag on system Yes ✓No_N/A_ 14. Are all cooking surfaces protected Yes—No— 46_ k.— 15. Proper hand portable extinguishers properly serviced Yes ✓No_ Problems found: Corrections made: )Ie , -eel Technicia Cert. sc�P- RBodJS Owner/Representive__a,� _Date ?P 9 z 1 Pioreer Fin&Secunry PO Box 597 E.Olympia,WA 9$540-0597 (360)491-8141 Pionea FUV. & Swurity August 16,2000 To..Mason County Fire Prevention Attn:Dave Salm Re:Aero Controls Sandblasting Room Addition Pioneer Fire&Security will expand the fire alarm system located ill the second warebouse of Aero Controls. The expansion includes the installation of one new 135 degree rate of rise Heat detector, and one 15175 candela hom strobe. This expansion will cover the new 15' x 30'sandblasting room as required by NFPA 72 and local Jurisdictional requirements. This expansion will not draw any current during stand-by,therefore the battery load calculations will not be affected. The new horn strobe will draw an additional 86 rnA during an alarm.In the event,this addition overloads the existing horn circuit;a hom power booster will be added to the system to accommodate the extra current being drawn. Please do not hesitate to call if I can be of further assistance. Sincerely, Aw,Iz- Robert A. Leeeb Pioneer Fire&Security . o . . . . . . . . . . . . . . . . . . . . . . . . Smi4 Enough to Know You.Big Enough to Serve You 1 INC. FIRE ALARM SYSTEMS SERIES lVS/tVS4 HORN S 1 ROBE APPLIANCES SERIES NH Description HORN APPLIANCE Wheelock's Newest Horn Strobe and Horn Appliances are the Series NS/NS4 Horn Strobe appliances and the Series NH Horn. both the Series NSINS4 and NH are of LOW CURRENT design with ZERO INRUSH, The horn appliances provide a Selectable continuous horn tone or temporal pattern (Code 3) tone when constant voltage from a Fire Alarm Control Panel (FACP) is applied. Each tone has two dB settings to choose from.All models(horn only or horn with strobe) may be Synchronized when used in conjunction with the Series SM or DSM Sync Moduie(s). Additionally, the horn may be silenced while SERIESNS/NS4 SERIESYN maintaining strobe activation of the Series NS/NS4 Horn Strobe Appliances. All of these features are achievable with either Wheelock's Patented 2 Wire Series NS or with the 4 wire Series N34(Audible will operate only with Features power applied to both strobe and audible). Approvals Include: Underwriters Laboratories UL The Series NS/NS4 Horn Strobe appliances and NH Horn 1971 and UL 464 Listings, FCC Part 15, European appliances are designed for maximum performance, Community (CE), California state Fire Marshal reliability, and cost-effectiveness while meeting or (CSFM), New York City (MEA), Pending: Factory exceaoing the latest requirements of NFPA 72 (National Mutual (FM) and Chicago (BFP) approvals. Fire Alarm Code),ANSI 117.1 (American National Standard ADA/NFPA/ANSI compliant. Meets OSHA 29 Part for Accessible and Usable Bui;dings and Facilities)and UL 1910.165. Standard 1971 (Standard for Signaling Devices for The Low Current. Hearing Impaired)and UL 464(Audible Slgnal Appliances). Zero Inrush, Series NS/NS4 Audible Strobe appliances,when properly Wall mount only. specified and installed in accordance with NFPAIANSI 2 Selectable tones and dB levels, standards can provide the Equivalent Facilitation allowed Continuous tone: anechoic, 90 or 95 d8; reverberant, under ADA Accessibility Guidelines (ADAAG General 82 or 88 dB Q 24 VDC_ Section 2.2) by meeting or exceeding the illumination Temporal Code 3 tone: anechoic, 90 or 95 dB.- which results from the ADA specified strobe intensity of 75 reverberant, 75 or 82 dB Q 24 VDC. candela at 50 feet. This is an illumination of.030 lumens ' Patent Pending Universal Mounting Plate for single per square foot. gang: double gang, 4" square, 100 mm European backboxes or Wheelock's SHBB shallow surface backbox When used with the Wheelock Series SM or DSM Sync . Notification Appliance Trim Plate(NATP)is availabie Modules, the continuous horn tone produces a for use when there is open space between the finished synchronized temporal (Code 3) tone (mandated by wall and the flush backbox. NFPA-72 (1993) with an effective date of July '96).This . Available with 15, 15/75, 30, 75 and 110 Cd strobe ensures a distinct temporal (Code 3) pattern when 2 or intensities, more horns are within hearing distance. If not synchronized, . 15/75 candela wall mounted strobes are listed at 15 the temporal sound could overlap and not be distinctive.At candela under UL Standard 1971 and meet 7S the same time the strobes on the clrcult may be candela Intensity on axis for ADA guldelines. synchronized This provides the ability to comply with . 2 versions available. ADA recommendations concerning photosensitive • 2-wite for both horn and strobe. epilepsy and meet NFPA raquirsmants when installing 2 or . 4-wire model. more visual appliances within the field of view.All of MIS . Non-Sync and Sync in one (synchronization requires plus the ability to silence the horn is achieved by using the Series SM or DSM Sync Module). only 2 WIRES(NS/NH). • Matching horn In 12/24V (Selectable). Copyright 1998 Wheelock, Inc. All rights reserved. NOTE:Ail CAu-nonS and WARNINGS are inerrofwd by the sYMW A.All womings are Qriorten in hold capitol letters. A WARNING' PLEASE REAL.THESE S7ECIFIGWIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY SUORE.OVNG,SPECIFYING OR AIPPLYNG 14IS PRODUCT,FAILURE TO COMPLY W174 ANY CF THESE INSTRWTIONS,CAUTIONS AND WARNIWS COULD PE S11r I to IMPROPER APPLICATION.INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SHUATION,WHICH COULD RESULT IN PROPERTY OAMAOE,ANC SERIUJS INJURY OR DEATH TO YOU ANC/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum --- from 20-31VOC(for 24 VDC models)or 10.5-15.6 VDC(for 12 Sori 35 NS VDC models).Note that NFPA-72(1996)specifies a flash rate •Average Current(Amperes) of 1 to 2 flasnes per second and ADA guldellnes specify a At 2 Audible Settings 4P 20,24,31 A 10.5.12 and 15.6 VDC flash rate of 1 to 3 flashes per seoond. 'Avers Current-w - Settin 95 dBA 24 volt models • All candela ratings represent minimum effective Strobe Intensity Ye I YS-ta1373 rlf:aAaNe w,N,T-W New based on VL 1971. _ • Series NS/Ns4 Horn Strobe products are Listed under UL 1971 for indoor use with a temperature range of 32' F to 120'F(0'C to 49'C)and maximum humidity of 85%. 'Atierage Current--with Law dBA Setti dBA 24 volt Ittodels • Series NH horns are Listed under UL 464 for audible signal vut , 9s•241sw NS-3a1575W N�.sew Il 247;w ++ appllanGlrs 20AYov 0.071 OJ83 3100 0,171 0.210 4 244MC 0066 ).�so 0.097 0,145 0.114 Specifications and Ordering Information 4 31.1)voc C.456 0.06e 1 0.077 0119 1141 *Avrsn4e Current-with Hi d13A Softing 95 dBQ 12 It models Ns.,tlrw Nst:1s7s1r WALL MOtla1T ONLY _ 1o.s VDC 0.15e O.zoa Order Input &RAN Mounting t2.ovdc-- 0137 0.17s Model NuwoberJ7806 ode tfellta a Cowell, Options' 1 0109 0.133 NS-2415W-FR905 24 15 I B,D E,F,G,H,J,O,R,S.X *Average Current-with Low dI3A Settin 90 dBA)12 volt frrodels .� NS•241575W-FR 24 15/75 B D,E F,G,HJ,6A,S,X fs1sW N>rtas7Rtr 10.5 VDC 0.l e8 0.199 11 NS-2430YI1•FR 7807 24 30 B,D,E.F.G.HJ.O,R.S,X 12.0VIX o133 010 NS-2475W-FR 7808 24 75 B,D,E,F,G,HJ,O,R,S,X r 11,11MC o.lna 0.12e NS-241-1 DW-FR 7809 24 110 B4O,E,F.G,HJ.O,R,S,X NS-12161N-FR 7815 12 15 B,D,E,F,GH,J,0.R,S.X --_ NS 121575WFR 781t3 12 15/75 B,D,E,FG.H,J.0.P,5,X Series NS41Serin NH Horn NS4-2415W-FR 7900 24 15 6,0,E,F.G,HJ,O,R,S,X "JIM r a Curren-Strobe Only,I ut 24 volt modds NS4-241575W-FR 7901 24 15/75 B,D,E,F,G,H,J,O,R,S,X Ns4usw N54.a41a7aw Isa•n3aw 105,1140sW N tallow NS4-243DW FR 7902 24 3O B,D,E,F,G,H,J,O,R,S,X zo•0,roc sow 0.oe o,0s5 0.157 0.199 24.0 vDC QOS4 0.068 0.0e1 0.133 0,161 NS4-2475W-FR 7903 24 75 B,D,EF,G,HJ,O,R,S,X a+.OVDc e.o47 o,a56 o.oss 0.106 0.11+ 04-24110WFR 7904 24 110 B,D,E,F,G,H,J,O,R 5,X 'Avenge Current-Ham Only NU/NM NS4.1215W-FR l 7910 12 15 B4O,E F,G,HJ,O,R,S,X Input w4h MI dBA Setting 85 dBA 24 volt models NS4-121575W414 1911 12 15/75 B,D,E,F,G,H.J,O.R,S.XEV�DC 154 t4tstr NS414167aW 4LMY ttt4 t1ISM rsa•u++ 1_ 0.020 0 020 0.020 0,021 0.020 NH 12124-R 7449 12r1�I - B,D,E,F,G,H,J,O,R,S,X D.oz7 0.027 o.oz7 D.o27 0.927 A 0.031 0.03, .034 0.034 0.034 SYNC MOME"' GMeItt 'Average Current-Hom Only NS4MH SM-12/24-R 6369 12 i .014 E,N t with Low dBA Setti (00 24 volt rrlodelS 24 ' .025 E,N N34-2411W 4•uwraw NSI•t13aw ega.147� 2nv1Yr 2a0vDC I 1 0.016 0.016 1016 0.016 OSMA2,124 R 6374 12 .020 W 24.0VDC 0•02+ C.021 01021 0021 24 038 w al.evoc opts DO7o 0.62E 0.026I a.o26 agM Current--Strobe 0 Inottiz volt models Mead 4'IN.'s Red can b.urea I,wmt Call Customer Service for oraw r,tw&CelNery. 164 Y2151M ILtt-12157Sw Model Coda SJfEx.W-rnp,F.fir4loorlhg or call customer Servn•a 4 other lettering is required 10.5 VDC 014e 0.+69 git.Feugol,R='ed,W at end=wr+:tot.4 4 We 12A VDC__•. OL126 Q-62 Ra►a to 04tu sheet S7000 for,nombng aoiains. 15.6 Voc O.t02 ar 30 Ewlmple NS-2051111-rR�..0--qx.l NS4�24AVFR. -pzQ NS-24761li-4-W118 'Average Current-Horn Only NS4/NH Na>falir "F__1wr Input with Hi d8A Setting 95 12 vDlt models VJaI ray Well yoluip - Na4•,zlsw.nal Ns4-uls7swnu,__ - _-_-- 4. n 1C.5 VDC OA,a a0l t " SM Sp,c IAAAes ore rotas far 3.o amperes at 12 a 24 VDC;DSM Duvi Sync Modules are rated 12.0YOC C Otq (10l a for 3.0 arnperas per{ir4tll.Trot maxk%rn,wnnw at intercorsraraed DSM modules is Iwarvy 16.E VDC !:.020 0.020 U31.We,tc Data S C100c or vvs,di8.W iretnlction(Po9,23 far SM or P83177 V 0$MI. uet 'Avoraoe Current-HOrn Only NS41NH input with Low dBA Setlirg180 d5A 12 volt models Ns,•,z,svr, Ns4.,21aLrinel dBA Rad s Fa Series NISMUMN Hem 110 5Q c _---- -- c.oDs 0.00e _--- - l 12.0 VDC _ 0909 0.001 amrtieranl dY rs 10 A kwAw c OA 1 n o1 l 0.011 OaunNiaa YtiveN r UL 44d a ion 11 VDC 24 b0C It voe 1+Voc Average current per rigLal*-4voDa Firoot c on TeWN&10.6,11,154 W.24 a 31 VOC co- ant m ous� Plo 82 46 94 55 rekd av,rji7 and pair rx"neio9s the UL 1s64 Moaage rang for Wh 91t4,vd De WW Herr, LOW 76 82 64 90 utfihmd VRMS,gee Insiammon Insiractiom(P83514), CAGE a High 76 92 69 90 Horn - LOW 70 75 04 9� 1 SERIES NSINS41INH QUICK REFERENCE GUIDE WON Non. Syrac s al! Strobe 1 unit m ' SIN or p�M ?A 1 2 fYf N - W- - 4175 - X 1y7 430 - X x P 0-247 FR x R X x 110x R �5 x 15WN•F T 1 15 x 4. 41575 • 1l X X 4• X FR 75 4110W-f R X 11 X NS •' W-FR X — X 2 1 5 1 1 X NH- 4- X y X Xx x Model r GWor is Red,can be ordered in White,call Custdryr Service for order t5dr b delKeq 141-1-1224 Can area rw CtIN Milled. w WARNINO:CONTACT WHMOCK FOR THL CURRENT"INSTALLATION INSTRUCTIONS"(P8E3111)AND"OENERAL M►FORMATIOIIR SHEET(P423E0)ON THESE PRODUCTS. THESE DOCUMENTATIONS DO UNDERGO PERIODIC CHANGES.IT is IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PWOR TO SPECIFYING OR INSTALLING THESE PROOUCi S,INCLUOING: • TOTAL CURRENT REQUIRED BY All APPLIANCES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. • FUSE RATINGS ON MAC CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STRDBES WITHIN A PERSON'S FIELD OF MEIN. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST bE WITHER THEIR RATED INPUT VOLTAGE RANGE. • INSTALLAWN OF 110 CANDEtA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATIONIIN OFFICE AREAS AND OTHER SPEC*ICATKIII AND INSTALLATION ISSUES. • USE SERIES NS/NS4/NH ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATMOO VDLTAGL.DO NOT USE SERIES NS/NS4/NH ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPUED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASIL • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SFIEETS COULD RESULT IN IMPROPER INSTALLATION,APPLICATION,ANO/OR OPERATION OF THESE PRODUCTS IN AN EIMUGENCT SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. • CONDUCTOR SIZE(AWG),LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDFAATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS,PAMICULARLV IN RETItOfIT INSTALLATIONS. Wiring Diagrams (for all modals) NS APPLIANCE NON-SYNCHRONIZED CE TO NS APPLIAN sr• SYNCHRONIZED WITH LROM + + NEX'RePLI,WR •-•i r^+••'r• PRECEOMG OR IWOF UK SM NODULE SINGLE JIM", rFOLL 0911AKCE — - — RMSTOR CLASS'B"NAC CIRCUIT OR FRCP (EOLR) WITH AUDIBLE SILENCE r ✓•�`^ rt—,jy A I I•{74 ML ^Y el•' FEATURE �i •:°•" VI_.r L—. + nwvrt 5lGMM INS AND NH APPLIANCES SYNCHRONIZED WITH DSM MODULE NS4(4 mrt)Appliance ledap&W#M Operation of Audible signal and Strobe' DUAL CLASS"A"MAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE DSM O Yw I ��.....,_� 9 SYNC- ` f•T s •OUT T 1 �- LRCM FP:C�L'.UrM C Nmx ANEL - TO NW.WPILWCE PRECL:LNG KA57OP Puri ,R SYNC' NOOLLL T � 4 i IIJtl{L[ TALN1eL! A w�c P -AuaeLE ..uo:as NFKusI _ } —µ •W] wx NB Nw p FRdN rACP 70 NIXT APPLIW CE AL114LZ NAC ek•VU PR i.i rt{' ECLUNC AGPWUCEt- J 1 -.. CR E7La I CMCWT RC YJRN I �� L 'Series NS4 Note:Audible will operate only with power applied to both strobtli and audible. Note:NSINS41NH must be set on Code 3 horn tone to 2Chiave synchronized temporal(code 3)tone. Refer to Installation Instruction (P83518,P83601, P83600 respectfully). Value dowthlned by FACO AAC Cir"(s) Refer to Series SM/DSM data sheet S3000 or installation instructions(P83123 for SM or P83177 for DSM). Wheelock products must be used within their published specifications and must be PROPERLY specified,applied,instahec.operated.maintained and operationally tested in accordance with thelr installation rrstruetions at the time of Instalation ens at least twice a year or more often and In accordance wltt,local,state and federal codes,regulations and laws.Specification,eppik:atbn,installation,operation,maintenance and testing must be performed by auallfied personnel for proper operation In accordance with all of the latest National Fire Protection A&GOCIatlon (NFPA)• underwriters'Laboratories(UL),National Eiaclrical Code(NEC),Occupational Safety aria Health Administration(OSHA).local,state,county,province, district,federal and other applicable building and fir*standards,guidelines,regulations.laws and cones including,but not limited to.all appendices and amendments and the requiraments of the local authority having)urlsdlction(AHJ). a . Architects and Engineers Specifications The notiflcatlon appliance(s)shall be Wheelock Series NSMS4 Horn Strobe and Series NH Horn appliances;and companion Series SM and DSM Sync Modules},or approved equals.Series NS/NS4 appliances shall be listed under UL Standard 1971(Emergency Devices for the Hearing Impaired for Indoor Fire Protection Service). Series NH Audible Horn, Series SM and DSM Sync 11 L lit under Standard 464 Fire Protective Si rlalln .Series NSINS4/NH Series SM and DSM shall be certified Modules she be U sad ( 9 g) to meet FCC Part 15,Class B. The appliances shall be designed for 2 or 4-wire operation and shall provide either a continuous horn/tone or temporal(Code3) tone when constantly applied voitage from a Notification Appliance Circuit (NAC) of the Fire Alarm Control Panel (FACP) or i synchronized temporal(Code 3)horn and synchronized strobe when used in conjunction with the Series$M or D$M Sync Module(s). When utilizing the Series NS4 in an independent(separate strobe and audible NAC circuits)operation, power shall be applied to both strobe and audible In order to have tho audible portion of the Series NS4 operate. Series NS shall be designed an that the horn tone may be silenced while malntalr,ing strobe activation(when used with the Series SM or DSM Sync Modules),The Series SM and DSM Sync Modula(s)shall incorporate two inputs from the Notification Appliance Circuits(NAC)for power connection from the Fire Alarm Control Panel;one for the strobe(NAC)circuit and one for the audible (NAC!circuit.A single 2 or 4-wlrs output shall control both the audible and visual appliances. Upon activation of the audible silence function of the Fire Alarm Control Panel,the horn tone shall be silenced while maintaining strobe activation Sound output at 10 feet shall be field selectable for 92 or 97 dBA anechoic for both continuous or temporal(Code 3)tone.Series NSINS4 shall provide listed strobe intensities o` I5, 15175, 30,75,and 110 candela for wall mount applications,with a flash rate of one flash per second minimum across the listed voltage range.The strobe shall incorporate a Xenon'flashtube enclosed in a rugged Lexan•lens. The Sync Module shall be designed and available in two versions;the Series SM 12/24 for control of a single Class B NAC circuit; and a dual output version,the Series DSM 12124 for control of either a single Class A or two Class 8 NAG circuits,The Series DSM dual circuit version shall provide the additional capability of"daisy-chaining",that is,the ability to Interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. DSM-12/24 coverage interconnection capability shall be for a maximum of 20 modules(40 Class"B'NAC circuits or 20 Class'A"NAC circuits). Rated average current requirement for the SM 12124 shall be-014 amperes a 12 VDC and.025 amperes C 24 VDC;the DSM 12124 shall be.020 amperes Q 12 VDC and.038 amperes a 24 VDC.The SM Sync Module shall be capable of handling a 3 ampere load at 12 or 24 VDC,The DSM Sync Modules shall be capable of handling a load of 3 amperes per clrcult in the Class-B'mode and 3 amperes per module in the Class"A'moCe at 12 or 24 VDC. Series SM or DSM Sync Modu as and Series NS/NS4 Horn Strobes shall be designed as a system for continuous activation of the strobes should the Sync Module contacts fell In the passive state(i a.,contacts remain closed).In thls default mode,the strobes shall revert to a non-synchronized default flash rate. Series NS/NS4/NH appliances shall be designed for operation at 12 or 24 VDC,over their respective listed voltage ranges of 10.5 to 15.6 VDC; and 20.0 to 31.D VDC. The units shall be designed for operation on filtered DC, or unfiltered VRMS. Rated average current for Series NS/NS4 shall depend upon votage and strobe intensity;the Series NS current shall be as low as.085 amperes for 24 VDC versions and.137 amperes for 12 VDC versions and the Series NS4 current shall be as low as.053 amperes for 24 VDC versions and ,133 amperes for 12 VDC versions(both with volume set at high dB output).Rated average current for Series NH(volume sot at high d8 output) shall be.021 amperee for 24 VDC versions and .014 amperes for 12 VDC versions. All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of#10 to#12 AWG wire size. Series NSINS4INH shall Incorporate a unique Universal Mounting Plate which shall allow mounting to single-gang,double-gang, 4"square.100 corn European backboxes or Wheelock's SHBB surface backbox.No additional trim plats shall be required for flush mounting. If required an NATP(Notification Appliance Trim Plate)shall be provided. Dimensions for the Series NS1NS4/NH shall be 4.75 inches square by 1.22 inches deep. Due to continuous dereiopumm rA our product,specifications and offerngs are subject to change without notice in accordance wilt Wheelock.Inc.standard terms and con6doft. 3 YEAR WARRANTY Distributed By, NATIONAL SALES OFFICE 1-800-631-2148 Canada 800.397.5777 ;�� E-mail; InfoOvvhealockinc.com http-//w,ivw.whaslockInc.com WHEELOCK, INC.■273 BRANCHPORT AVENUE■LONG BRANCH, N.J.07140■732-222-6880 a FAX: 732-222-8707 92100 aav 516 V '09i�'001 14:47 FAX 360 427 9438 Shelton Fire Z 01 .".FR-C8-3'. TFU y:?5 PMS/SA I SEA CW GNTR FAX, N0, 2363644136 P. CI acx�a -�� -oo0 2� SAI "NowrIjvvzvT CommAND CENTER 5ecurlty Associates Intp-mational, Inc. P.O. Box 65027 Seattle,WA.98155 (206) 362-1482 (206)U4 4136 'March. 9,2001 Shelton Fire Department '�k C 12..W. FranklLn Shelton,W?:.98584 �j�` �C) �- 52 ,2016 Rye- Notice of disconnect of monf taring of a required fire alarm System: Protection One �- 6844 S. 2204�street Kent,WA.9M2 (503)277=7288 Per. Debbie Koffei has requested a disconnect of monitoring serv-ices.provided by Alarm Monitoring Service;-Inc-AG.- -7 Aero Controls 520 V4. Dayton Airport Roa Shelton,,WA.98584 Effective: March 8,2001 10/19/2 05 W9-J 13: 15 FAX 360 427 9438 SHELTON FIRE �y�[ 0003/012 SMITH FIRE SYSTEMS, INC. DATE 9/29/05 1106 54TH AVE. E. PH; (253) 926.1880 JOB # 7231 TACOMA,WA 98424 FAX: (253) 926-2350 CONFIDENCE TESTING FIRE ALARM NAME AERO CONTROLS, INC-SHELTON ADDRESS 520 W DAYTON AIRPORT RD, SHELTON,WA CONTACT ALCAREY PHONE (253)269-3144 NAME OF TESTER i�� /,��j��L� CERTIFICATION NO. 7771q DATE OF INSPECTION _ September 29,2005 TYPE OF INSPECTION ANNUAL CONTROL PANEL MANUFACTURER SILENT KNIGHT MODEL NO. 5207 NUMBER OF INITIATING CIRCUITS 140- & NO. OF SIGNAL CIRCUITS 466 Ll BATTERY VOLTAGE 2--t . 9 S VOLTS CHARGE CIRCUIT VOLTAGE 2'J• 23 VOLTS BATTERY VOLTAGE UNDER FULL LOAD Z 5- 14 VOLTS (SIGNALS OPERATING) 1. Trouble signal with AC power off YES NO ❑ N/A ❑ 2. System operates satisfactory on standby power YES Lv7 NO ❑ NIA ❑ 3. All signals operate on AC power YES lJ NO ❑ N/A ❑ 4. Have all alarm notification appliances been checked for proper operation? YES ❑ NO ❑ NIA ❑ 5. All circuits checked for electrical supervision YES NO ❑ N/A ❑ 6. Control panel checks made per manufacturer's instructions YES NO ❑ N/A ❑ 7. All auxiliary equipment operates (Elevators, fans, dampers) YES ❑ NO ❑ N/A 8. Central station or remote connection YES NO ❑ N/A ❑ Name of Monitoring Company ALARM CENTER 9. Key to panel available YES NO ❑ N/A ❑ 10_ Operating instructions at panel? YES NO ❑ NIA ❑ 11. Service Label or Tag (SFC Appendix III-8) YES Lam' NO ❑ N/A ❑ 1 ki �. 10/19/2005 WED 13: 15 FAX 360 427 9438 SHELTON FIRE IZO05/012 1 EQUIPMENT TESTED is TYPE OF EQUIPMENT NUMBERS OF SATISFACTORY NO. OF UNITS UNITS TESTED YES NO N/A IN BUILDING Bells, Horns, Chimes Voice Alarm Speakers 20 20 Visual Alarm Device 19 y/ 19 Trouble Indicators 2 2 Super. Switch (Auto. Spr.) 0 0 Auto Spr. Flow Switches 0 0 Smoke Detectogs) 113 113 Heat Detectors) 21 21 Manual Pull Stations 15 / 15 Ventilation Controls Operate 0 �. 0 Central Station 0 Annunciators 1 Elevator Call Down 0 0 Fire Damper/Smoke Dampers 0 ✓ 0 Phone Jacks 2 — 2 Auto. Door Unlocks - (Fallsafe) 0 ✓ p Auto. Door Release 3 ✓ 3 Other 0 0 PROBLEMS FOUND: CORRECTIONS MADE: DATE CORRECTED BY THIS IS TO CERTIFY THAT THE FIRE ALARM SYSTEM HAS BEEN PROPERLY TESTED AND INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT. SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma WA 98424 (253)926-1880 �J 6 ig Ir/ for Print Name J Date "IJ T UCYVAJ 0� 29�5 Si ature ofjwner or Presentative Print Name Date 2 l s I SMITH FIRE SYSTEMS MANAGEMENT,LLC 1106 54th Avenue East • Tacoma,Washington 98424 October 1, 2009 Shelton City Fire Department 525 West Cota St Shelton, WA 98584 Attention: Fire Marshal Enclosed please find copies of the report(s) for the work we recently completed in your jurisdiction. If you have any questions or need any further information, please contact me at 253- 248-2364 or email me at ahoeft@smithfire.com. If you would like to receive reports via email please send me your email address. Sincerely, Angela Hoeft Angela Hoeft Customer Service Smith Fire Systems Management, LLC Enclosure(s) qSYStSMITH FIRE A 5 AGEMENT, LLC DATE 9130/09 +ctaec-emu CONFIDENCE TESTING FIRE ALARM JOB # 27671 1106 54th Avenue East,Tacoma,WA 98424 Phone: (253)248-2000 Fax: (253)248-2360 SITE NAME AERO CONTROLS, INC— SHELTON ADDRESS 520 DAYTON AIRPORT ROAD, SHELTON,WA 98584 CONTACT ALLAN CLAREY PHONE (253)269-3144 NAME OF TESTER 14A!2K /�.,,,'1 Ab b0x CERTIFICATION NO. SL P NJ- ©L-731 DATE OF INSPECTION September 30, 2009 TYPE OF INSPECTION ANNUAL CONTROL PANEL MANUFACTURER SILENT KNIGHT MODEL NO. 5207 NUMBER OF INITIATING CIRCUITS 16 NO.OF SIGNAL CIRCUITS 4 BATTERY VOLTAGE -�-7• oZ- VOLTS i CHARGE CIRCUIT VOLTAGE ,30*3 VOLTS BATTERY VOLTAGE UNDER FULL LOAD o7 1 VOLTS (SIGNALS OPERATING) 1. Trouble signal with AC power off YES M' NO ❑ N/A ❑ 2. System operates satisfactory on standby power YES [V]' NO ❑ N/A ❑ 3. All signals operate on AC power YES 0 NO ❑ N/A ❑ 4. Have all alarm notification appliances been checked for proper operation? YES &J" NO ❑ N/A ❑ 5. All circuits checked for electrical supervision YES B�r' NO ❑ N/A ❑ 6. Control panel checks made per manufacturer's instructions YES E;K NO ❑ NIA ❑ 7. All auxiliary equipment operates (Elevators, fans, dampers) YES ❑ NO ❑ N/A 8. Central station or remote connection YES V NO ❑ N/A ❑ Name of Monitoring Company ALARM CENTER-63-2423 9. Key to panel available YES hZ- NO ❑ N/A ❑ 10. Operating instructions at panel? YES S?"' NO ❑ NIA ❑ 11. Service Label or Tag (SFC Appendix III-B) YES V NO ❑ N/A ❑ 12. Did you sign off Item 8 on the Elevator Log YES ❑ NO ❑ N/A (" AERO CONTROLS, INC- SHELTON 1 of 2 t , EQUIPMENT TESTED TYPE OF EQUIPMENT NUMBERS OF SATISFACTORY NO. OF UNITS UNITS TESTED YES NO N/A IN BUILDING Bells, Horns, Chimes 20 20 Voice Alarm Speakers Visual Alarm Device 19 ✓ 19 Trouble Indicators 2 2 Super. Switch (Auto. Spr.) Auto Spr. Flow Switches Smoke Detector(s) 113 113 Heat Detector(s) 21 21 Manual Pull Stations 15 ✓ 15 Ventilation Controls Operate Central Staticn Annunciators 1 1 Elevator Call Down Fire Damper/Smoke Dampers Phone Jacks 2 ✓ 2 Auto. Door Unlocks - (Failsafe) Auto. Door Release 3 ✓ 3 Other PROBLEMS FOUND: CORRECTIONS MADE: DATE CORRECTED BY THIS IS TO CERTIFY THAT THE FIRE ALARM SYSTEM HAS BEEN PROPERLY TESTED AND INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT. - SMITH FIRE SYSTEMS MANAGEMENT, LLC 1106 54th Avenue East, Tacoma, WA 98424 Phone: (253) 248-2000 Faux:/(253) 248-2360 igW-r-1 ct Print Name Date �.jFw(- q 13(-t Si re of O ne or Rep esentative IPrint Name Date AERO CONTROLS, INC— SHELTON 2 of 2 6v;) I tlkt�� _ f 0A�At (2531926-1880•FAX(251)926-2350 SMITH FIRE SYSTEMS MANAGEMENT,LLC 1106 54th Avenue East • Tacoma,Washington 98424 October 14, 2009 Shelton City Fire Department 525 West Cota St Sheiton, 1iVA 98584 Attention: Fire Marshal Enclosed please find copies of the report(s) for the work we recently completed in your jurisdiction. If you have any questions or need any further information, please contact me at 253- 248-2364 or email me at ahoeft@smithfire.com. If you would like to receive reports via email please send me your email address. Sincerely, Angela Hoeft Angela Hoeft Customer Service Smith Fire Systems Management, LLC Enclosure(s) U' U -H- o- ( (D ( This fcxrn is the property of: � Ferreli's Fire Extinguisher Company, Inc. 41 - CJ 0 ate: RANGE HOOD SYSTEM SEMIANNUAL PERFORMANCE EVALUATION Name of Facility: A Pi /o UU Address: 152 /r. O 1' rj �L Contact Person: QU t°e Phone# ( � Z0 l — Type of System: wet Chem Chem /. Dry Coz H2O O#W Make of System: j'�\/Y-064 eovl P(/-" — �50 Size_ L ��L i7s 2o©G�3s Yes No N/A 1. Cylinder's pressure gauge or weight is at acceptable level. 2. System is free of any prior dischargeidamage or tampering. 3. Ail piping and conduit is immobilized with proper hangers and brackets. 4. All nozzles are in proper positions. 5. All nozzles are covered by blow-off caps. 6. Date fusible links last changed. (Required annually) Q T System operated properly from most remote fusible link. 8. System operated properly from all manual actuators. 9. Automatic shutdown of fuel/power operated properly. 10. Manual actuators are unobstructed and in path of egress. 11. Date of last hydrostatic test of cylinder. -zoo 12. Is system alarmed? 13. All cooking surfaces are protected. 14. Inspection and service tag on system cylinder. X_ 15. System is now fully operational and free from obstructions. 16. Is the hood and duct free from grease and sludge accumulation? , 17. Last date pressurized dry chem systems had dry chem examined: 20 0 1 Problems Found: Corrections Made: Fusible Links Replaced, This range hood system has been evaluated in accordance with manufacturer's recommendations and NFPA standards. Performance Evaluation Completed by: C� `pj^e Date: Agency: Ferrell's Fire Extinguisher Company, Inc. Address: 8420 South 222nd Street Kent WA 98031 Phone# { 253 ) 924-0511 Business License# 600 359 710 Fax# ( 253 ) 872-8341 A copy of this report may be forv►ardW to the authority having jurisdiction. ferrelisfireequipmenta.msn.com ( 541 9 6-1880•FAX(?,rim 26- 'i50 SMITH FIRE SYSTEMS MANAGEMENT,LLC 1106 54th Avenue East • Tacoma,Washington 98424 October 5, 2010 Shelton City Fire Department 525 West Cota ST Shelton, WA 98584 Attention: Fire Marshal Enclosed please find copies of the report(s) for the work we recently completed in your jurisdiction. If you have any questions or need any further information, please contact me at 253- 248-2008 or email me at dvandaveer@smithfire.com. If you would like to receive reports via email please send me your email address. Sincerely, Dena Vandaveer Dena Vandaveer Customer Service Smith Fire Systems Management, LLC Enclosure(s) ooc) ao d SMITH FIRE SYSTEMS MANAGEMENT, LLC DATE _ -� .. G°"""''"�'�"'HH"""` CONFIDENCE TESTING FIRE ALARM JOB # 1106 54th Avenue East,Tacoma,WA 98424 Phone: (253)248-2000 Fax: (253)248-2360 SITE NAME AERO CONTROLS, INC—SHELTON ADDRESS 520 DAYTON AIRPORT ROAD, SHELTON,WA 98584 CONTACT ALLAN CLAREY PHONE (253) 269-3144 NAME OF TESTER �/,4/j,P'/�,{7PJ�ts7c CERTIFICATION NO. S'CPM -7 3 I DATE OF INSPECTION TYPE OF INSPECTION ANNUAL CONTROL PANEL MANUFACTURER SILENT KNIGHT MODEL NO. 5207 NUMBER OF INITIATING CIRCUITS 16 NO.OF SIGNAL CIRCUITS 4 BATTERY VOLTAGE ZL• t 9 VOLTS CHARGE CIRCUIT VOLTAGE VOLTS BATTERY VOLTAGE UNDER FULL LOAD �•�-7 VOLTS (SIGNALS OPERATING) 1. Trouble signal with AC power off YES NO ❑ N/A ❑ 2. System operates satisfactory on standby power YES Q� NO ❑ N/A ❑ 3. All signals operate on AC power YES / NO ❑ N/A ❑ 4. Have all alarm notification appliances been checked for proper operation? YES [� NO ❑ N/A ❑ 5. All circuits checked for electrical supervision YES [� NO ❑ N/A ❑ 6. Control panel checks made per manufacturer's instructions YES 19/ NO ❑ N/A ❑ ❑ 7. All auxiliary equipment operates (Elevators,fans, dampers) YES ❑ NO N/A 8- Central station or remote connection YES &3/ NO ❑ N/A ❑ Name of Monitoring Company ALA BM CENTER-63-2423 9. Key to panel available YES —/ NO El N/A 10. Operating instructions at panel? YES E2 NO ❑ N/A ❑ 11. Service Label or Tag (SFC Appendix III-B) YES W NO ❑ N/A ❑ 12. Did you sign off Item 8 on the Elevator Log YES ❑ NO 0 N/A Rf EQUIPMENT TESTED TYPE OF EQUIPMENT NUMBERS OF SATISFACTORY NO. OF UNITS UNITS TESTED YES NO N/A IN BUILDING Bells, Horns, Chimes 20 20 Voice Alarm Speakers Visual Alarm Device 19 19 Trouble Indicators 2 i/ 2 Super. Switch (Auto. Spr.) ✓ Auto Spr. Flow Switches / Smoke Detector(s) 113 Heat Detector(s) 21 ✓ 21 Manual Pull Stations 15 15 Ventilation Controls Operate _ t/ Central Station 1 Annunciators 1 1 Elevator Call Down ✓� Fire Damper/Smoke Dampers Phone Jacks 2 2 Auto. Door Unlocks - (Failsafe) Auto. Door Release 3 3 Other PROBLEMS FOUND: CORRECTIONS MA.DF: DATE CORRECTED BY THIS IS TO CERTIFY THAT THE FIRE ALARM SYSTEM HAS BEEN PROPERLY TESTED AND INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT. FOtP:. ; 'O SMITH FIRE SYSTEMS MANAGEMENT, LLC -, .�-.:voc..r.{ 1106 54th Avenue East, Tacoma, WA 98424 Phone: (253) 248-2000 Fax: (253) 248-2360 ignature Inspector Print Name Date Signature of owner or Representative jPrint Name Date I 3 Li2jWZ=15-C Zp SMITH FIRE SYSTEMS MANAGEMENT, LLC / DATE CONFIDENCE TESTING FIRE ALARM JOB# 1106 54th Avenue East,Tacoma,WA 98424 Phone: (253)248-2000 Fax: (253)248-2360 SITE NAME AERO CONTROLS, INC—SHELTON ADDRESS 520 DAYTON AIRPORT ROAD,SHELTON,WA 98584 CONTACT ALLAN CLAREY PHONE (253)269-3144 NAME OF TESTER VW1,/l CERTIFICATION NO. DATE OF INSPECTION l!i �� TYPE OF INSPECTION ANNUAL CONTROL PANEL MANUFACTURER SILENT KNIGHT MODEL NO. 5207 NUMBER OF INITIATING CIRCUITS 16 NO.OF SIGNAL CIRCUITS 4 11 ( N-14G BATTERY VOLTAGE 11, <j ,S1 VOLTS CHARGE CIRCUIT VOLTAGE j$,7 0 VOLTS BATTERY VOLTAGE UNDER FULL LOAD ) Z-,77//Z,14 VOLTS (SIGNALS OPERATING) 1. Trouble signal with AC power off YES NO ❑ N/A ❑ 2. System operates satisfactory on standby power YES NO ❑ N/A ❑ 3. All signals operate on AC power YES NO ❑ N/A ❑ 4. Have all alarm notification appliances been checked for proper operation? YES [!I' NO ❑ N/A El 5. All circuits checked for electrical supervision YES Ef NO ❑ NIA ❑ 6. Control panel checks made per manufacturer's instructions YES 0 NO ❑ NIA ❑ 7. All auxiliary equipment operates (Elevators,fans,dampers) YES ❑ NO ❑ N/A 8. Central station or remote connection YES W NO ❑ N/A ❑ Name of Monitoring Company ALARM CENTER-63-2423 9. Key to panel available YES Qr NO ❑ N/A ❑ 10. Operating instructions at panel? YES V NO ❑ N/A ❑ 11. Service Label or Tag (SFC Appendix III-B) YES E/ NO ❑ N/A ❑ 12. Did you sign off Item 8 on the Elevator Log YES ❑ NO ❑ N/A 0 AERO CONTROLS, INC-SHELTON 1 of 2 4 � EQUIPMENT TESTED TYPE OF EQUIPMENT NUMBERS OF SATISFACTORY NO.OF UNITS UNITS TESTED YES NO N/A IN BUILDING Bells, Horns, Chimes 20 Voice Alarm Speakers Visual Alarm Device / 19 Trouble Indicators Z 2 Super. Switch Auto. S r. Auto S r. Flow Switches f Smoke Detectors t 1 3 113 Heat Detectors Z J 21 Manual Pull Stations t 15 Ventilation Controls Operate Central Station Annunciators 1 Elevator Call Down Fire Damper/Smoke Dampers Phone Jacks Auto. Door Unlocks - Failsafe / Auto. Door Release 3 ` 3 Other PROBLEMS FOUND: CORRECTIONS MADE: DATE CORRECTED BY THIS IS TO CERTIFY THAT THE FIRE ALARM SYSTEM HAS BEEN PROPERLY TESTED AND INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT. SMITH FIRE SYSTEMS MANAGEMENT, LLC 1106 54th Avenue East, Tacoma, WA 98424 Phone: 253 248-2000 Fax: 253 248-2360 14 4"' Ignature Inspector PIA Name Date Ignature of owner or Representative Print Name Date AERO CONTROLS, INC-SHELTON 2 of 2 j a 1 SMITH FIRE SYSTEMS MAN;. EMENT, LLC RANGEHOOD SYSTEM DATE 2k- l( 1106 54th Avenue East, Tacoma, WA 98424 JOB# Phone: (253)248-2000 Fax: (253)248-2360 a SITE NAME AERO CONTROLS, INC- SHELTON ADDRESS 520 DAYTON AIRPORT ROAD SHELTON,WA 98584 CONTACT ALAN CLAREY PHONE (253)269-3144 TECHNICAN'S NAME: 'FYavi h 5 D u Y 1 S.F.D.#: S s F2 TYPE OF INSPECTION: ANNUAL -V ACCEPTANCE ❑ SEMI-ANNUAL ❑ ALARMED ❑ MAKE OF SYSTEM ?Vy -o SIZE uI X f G l 5 FUEL SHUT-OFF: GAS ❑ ELECTRIC ❑ 1. Checked pressure gauge indicator in operable range YES x NO 2. All lead and wire seals are intact YES k NO 3. There are no visible signs that system has fired or been tampered with YES Y No 4. All piping and conduit immobilized with proper hangers and brackets YES X NO 5. Positioning of all nozzles okay YES y No 6. Self-closing caps YES >r No 7. Replaced all protective covers on nozzles YES /K NO 8. Fuse links replaced YES '$ NO 9. Tested system operation from terminal link for proper operation YES 'f NO 10. Tested system operation with manual remote for proper operation YES NO 11. Tested system operation and proper operation of micro switch YES_ NO 12. System is now visible and free from obstructions YES Y NO 13. Inspection and service tag on system cylinder YES Y NO 14. All cooking surfaces are protected YES- No 15. Proper hand portable extinguishers properly serviced YES A NO 16. Hydro test required by: 2-0 1 3 PROBLEMS FOUND 4 �] T I SMITH FIRE SYSTEMS MANAGEMENT, LLC 1106 54th Avenue East, Tacoma, WA 98424 Phone: (253) 248-2000 Fax: (253)248-2360 NW ignature Inspector Print Name Date ignature of Owner or Representative lPrint Name Date I, 6 I Fire Alarm System Secondary Battery-set Calculation Worksheet Standby Total Alarm Total Standby Alarm/Transmit AES Product Current QTY Current(Amps) Current(Amps) QTY Current (Amps) (Amps) 7707P-88-ULP-10.4000 X 1 = 0.400 1.5500 X 1 = 1.550 Total System Total System Standyby Current (Amps 0.400 Alarm Current (Amps 1.550 ## Hour Standby Required Required Standby Time Current Standby Capacity Required Alarm Time Alarm/Transmit Alarm (Amps) (Amp-Hours) (Hours) Current (Amps) Capacity (Amp- ours 24 X 0.400 = 9.600 1 X 1.5500 = 1.550 Required Standby Required Total Capacity Capacity Alarm Capacity (Amp-Hours) (Amp-Hours) (Amp-Hours) 9.60 + 1.550 = 11.150 01) a (h i O rn aes-corp.com ES" ,I SECURITY CORPORATION RECEIVED INNOVATION MAY 0 7 2020 615 W. Alder Street 7707 Fire Subscribers IntelliNet A Newer, Smarter Alarm Communications Platform Feature Highlights • Leverages state of the art technology • Applies advanced security protection - • Offers flexible power and configuration options �L • Engineered for backward compatibility with legacy systems NFPA LISTED • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies(MCT)feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablets and PCs • Plus many more... Key Benefits • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP)without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3)Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards r Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network.The AES Model 7707 is ideal for commercial fire applications.With the AES-IntelliPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service(POTS)lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status.The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop,tablet, or integrated Universal Serial Bus(USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary D Subscriber ---------- _ / ; I N B)Fire Subscriber t I All rV-1e Nonap—,Syr— B ——————————— ■t! ,es —�—— Primary AES-MuftlNe[Receiver t I I A)Alarm / I Panel / I Secondary AES4ftltiNet Receiver / 1 1 / 1 . B -C Alarm Automation ----A ---------- QIPLinks Customer Location Mesh Radio Technology I Central Monitoring station Alarm Panel&ALS 5ubscriber Multi-path AES-IntelliNet®Network Primary&Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers'intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units.A FACP Power Supply Adapter is required for certain configurations when using flexible power options.The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out,and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources HA to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL& ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversing Polarity,4 Supervised)with Multiple Communication Technologies(MCT), Red Enclosure P g ) IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy • • - 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module,and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone,8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone,8 Supervised Zones, Red Enclosure 7744F-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber,4x4 Zone,4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity,4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version . . Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs and message communication 4+4:4 reverse polarity input and USB access for software upgrade WEIGHT 4 individually programmable 5.8 lbs(2.6 kilograms) E.O.L.type zone inputs REMOTE ANNUNCIATOR excluding battery Optional 7794A AES-IntelliPro for AES Model 7740 13 Ibs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator,supervised 10 Ah battery Modem Ile and Modem Illa2 COMPATIBLE RECEIVERS RADIO FREQUENCY UL LISTINGS 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 loth Edition 450-470 MHz Standard for Control Units and CONFIGURATION INTERFACE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone,tablet, Equipment for Fire Signal laptop,or PC ANTENNA Receiving Centres and Systems 2.5 d13 tamper resistant antenna CURRENT CONSUMPTION included, mounts on enclosure Standby w/charged backup battery: Optional remote mounting TROUBLE OUTPUT—A C K 200 mA(1.2 A Transmitting) antenna available DELAY/ANTENNA CUT Standby+charging backup battery: Form C relay,fail secure, rated 24V 900 mA(1.9 A Transmitting-MAX) POWER INPUT DC 1 A resistive, unsupervised AC SOURCES POWER OUTPUT Transformer: Class 2 RESET BUTTON 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current(40 VA MIN) ELK ELK-TRG1640, OPERATING TEMPERATURE ENCLOSURE MATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included) DC SOURCES(includes FACP) STORAGE TEMPERATURE FINISH COLOR 24V DC Regulated Power Supply 14 to 140°F(-10 to 6o°C) Red with Subscriber Rechargeable Battery RELATIVE HUMIDITY VISUAL INDICATORS 1.9 A max current 0 to 93%, non-condensing Front panel LCD (2 x 20 alphanumeric character BACKUP BATTERY RECHARGE CAPABILITY backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell,size based on subscriber from 10-12 Ah (ALM,Trouble,Tx, Rx,WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. 00000 Peabody,AES Corporation 1 285 Newbury Street I •.0 United States MASON COUNTY FIR20�� _. DEPARTMENT OF COMMUNITY DEVELOPMENT - Mason County Bldg. 111, 426 West Cedar Street, Shelton, WA 98584 -=_ s'' www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma(360)482-5269 a_ 7854 Mason County Fire Protection System Permit Application/Underground System Incomplete applications will not be accepted Q _ _ c Owner: I \elm �1s Phone#: ��3 2 - u Mailing Address: st �6ity: MUM State: Zip: Site Address:52a w 1�Qy 'PA City: State" Zip: Parcel #: Legal Description: !RUEEIVED 01 2020 Lien/Title Holder: 6151f t. Alder Street Address: State: Zip: Contractor: Phone #: Address: City: State: Zip: Contradtor Registration#: Expiration Date: Building Square Footage (existing&proposed): lst / 2nd / 3rd / Building Use: Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: New System: Wet Dry Modification: X Standpipe: Wet Dry Fire Underground Automatic Fire Alarm: X Fire Pump Hood&Duct: Dry Chem: Wet Chem: UL certified Monitoring company: Mw AAM Phone#: 2-0(p Contractors Bid Price: $ 500' 00 IACommunity DevelopmentWILDINGTire Protection System Permit Application.doc MASON COUNTY COMMUNITY SERVICES Permit No: PERMIT ASSISTANCE CENTER: r •BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL E C ��f s 130 615 W.Alder Street,Shelton,WA 98584 Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone �� O L��� Belfair. 360)275-4467•Phone Elma: 360)482-5269 BUILDING PERMIT APPLICATION 615 W. Alder Street PROPERTY OWNE,.}R-,I,,NFORMATION: CONTRACTOR INFORMATION: NAME: iKyZ � 't y l S_ NAME:6u •rd 1(.LO �(.L1.til�"Li ,C }(1 sk'rn S MAILING ADDRESS: 1 U 0 20 St N W MAILING ADDRESS: 17IT 3 1 t S• CITY: vM STATE:v ZIP: C19V0 C1TY: `tea - STATE: VO4 ZIP:01 sSl PHONE#1: 2-5 w"I-3144 PHONE:ZIIO-i -1 CELL: PHONE#2: 0-gi/ I&A Ck- i bj-G `YYt EMAIL: L&I REG# LAWM09Se334%5 EXP.Qcf/-3U/:2 L PRIMARY CONTACT: OWNER❑ CONTRACTOR 9 OTHER❑ NAME E h W bf+1n FI S-I' U-1 EMAIL MAILING ADDRESS_]^=! iG+ �AyP .S• CITY <reGL-hIt- STATE 1M4- ZIP­q-s-13L1 PHONE x 27? CELL PARCEL INFORMATION• PARCEL NUMBER(12 Digit Number) ZONING LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT SITE ADDRESS 520 V%f • D(,0j-VAr) CITY A- O DIRECTIONS TO SITE ADDRESS IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO❑ SNOW LOAD: psf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Checkall thatapply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW❑ ADDITION❑ ALTERATIONS REPAIR❑ OTHER ❑ USE OF STRUCTURE(Restdeac4 Garage Commercial Bldg,Etc) IS USE: PRIMARY❑ SEASONAL❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS HEATED STRUCTURE? YES(Whole B,,lldpdg)❑ YES (,P,.a1[,]ofBldg)❑ NO❑ DESCRIBE WORKIIIS G k\ T 1�rJ rC_Cl��� YY13111'1"C�I' �T`V( SQUARE FOOTAGE:(proposed) 1ST FLOOR sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER❑ / NEW❑ EXISTING❑ PLUMBING IN STRUCTURE? YES❑ NO❑ Ifyes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES❑ NO❑ EXISTING SQ.FT. EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that 1 am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permitlapplication becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTMTY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON /11 WX �' / CQUNCODE 14 08A2)vy Signaturr✓61'OWNER(Must be s' ned by the OWNER Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGSINOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT VM1ollAn V%3AT 0 W W = Fire Alarm is Silent Knight 5207 ` located in south end of building, ES Radio to go in next to panel. rti t OPTvw ` y .WN% w AP r. Aero Controls - Warehouse and Distribution _ 5 W. Dayton Airport Rd. Shelton WA 98584 i iz W