HomeMy WebLinkAboutFIR2006-00020 Sprinklers Bldg E - FIR Permit / Conditions - 1/8/2009 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext. 352 Shelton, WA 98584 P14 FIRE PROTECTION PERMIT FIR2006-00020 APPLICANT: G R WILSON RECEIVED: 6/7/2006 CONTRACTOR: LICENSE: EX.P: ISSUED: 1/8/2009 SITE ADDRESS: EXPIRES: 7/8/2009 PARCEL NUMBER: 122185000050 LEGAL DESCRIPTION: LAKELAND VILLAGE#12 PHASE II LOT: 50 (CONDOMINIUM SITE - 7 1/2 UNITS ALLOWED PER ACRE) PROJECT DESCRIPTION: sprinkler system for building E GENERAL INFORMATION System Information Type of Use: RES Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 5 Flow Switches: Visual Devices: Door Releases: Hood& Duct?: N Pressure Switches:: Smoke Detectors: Duct Detectors: Dry Chemical?: N Zones: Heat Detectors: Wet Chemical?: Y Sprinkler?: Y Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: GUARDIAN SECURITY First Floor: Type Amount Due Amount Paid Monitoring Phone No.:(360) 779-5453 Second Floor: Sprinkler System Plan $100.00 $100.00 Auto Fire Alarm?: Third Floor;: Sprinkler System Permit $100.40 $100.40 Total: $200.40 $200.40 FIR2006-00020 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FIR2006-00020 CONDITIONS FOR FIR2006-00020 1.) The system must be installed per NFPA 13 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The ownerorthe agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structur r revie and�ins'pe�tion.OWN ER OR AGENT: �/�/C' DATE: FIR2006-00020 Please refer to the following pages for conditions of this permit. 2 of 4 r6ors COVE t MASON COUNTY Shelton (360) 427-9670 DEPARTMENT OF COMMUNITY DEVELOPMENT Belfair (360) 275-4467 Permit Processing/Inspections/Addressing Elma (360) 482-5269 Mason County Bldg.III 426 W.Cedar �as4 P.O.Box 186 Shelton,WA 98584 GR Wilson PO Box 1530 Allyn, WA 98524 Re: FIR2006-00020 To Whom it may regard, The above reference sprinkler system permit has been approved. According to our records the system has been installed and inspected. The permit needs to be paid for and permit picked up. The fee's due are $100.40. Please make check payable to Mason County Treasurer. Our office hours are 8:00 am—4:30 pm with the exception of December 241h we will be closed at 3:00pm. If you have any questions or concerns in this matter please contact me. Thank you for you attention to this matter. Best Regards, Tricia Woolett Permit Specialist II Mason County Fire Marshal Office PO Box 186 Shelton, WA 98584 360.427.9670. ext. 281 tw@co.mason.wa.us 9/18/2006 12:1 OPM Fees Associated With Or too Case#: FIR2006-00020 Due Type Description Revenue Account Number Date Paid By Fees Paid History SSPC Sprinkler System Plan Check 001.125.140.345.83.00.0030 6/7/2006 NJP 100.00 100.00 0.00 Sprinkler System Plan Check 001.125.140.345.83.00.0030 6/7/2006 NJP 0.00 0.00 FIR1 Sprinkler System Permit Fee 001.125.140.322.10.00.0030 9/18/2006 CMH 100.40 0.00 100.40 Total Fees:$200.40 Paid:$100.00 TOTAL REMAINING DUE: $100.40 8 • c� — Page 1 of 1 CaseFeesxpt FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION FACILITY ADDRESS ��i CITY ZIP HONE NAME �r Lt�� l� LL ST L l� �& a W4 31nc7 -5 INSPECTOR C I v(TL AGENCY , DATE 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD j - /3-D6 ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION NO, DEFICIENCY REFERENCE REQUIRED REQUIRED BY DATE F�,✓ � ✓��2 in�s��r�:inr/ o� �dL"0 6-� �cJ -�� �c �SGvrlf-cony✓ l f�! 1^i'4`'I� /n/ coo t-'�i oF�' s`�� rtt'� ��i7�. � �7'o.,.a'� �{-i4 �'S4��`/-fr3Zv✓ �I-- y✓i�� 6�� i rJs 774'1-L - l/- ��- o Q- Q 2 cn Q W 00 L0 a00 iL P D C N U H 3 Z 'O L N h O c^ U °' ° N O] L W Z >-N O O70 P N O v s.•y .. - r -- THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS 1Z NO LATER THAN THE DATES INDICATED I i PAGE OFF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal — Pink Copy: Fire District FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION FACILITY ADDRESS CITY ZIP PHONE NAME LL ! S% LlrUf� 1�L• Ll ► ^/.. t _�'%3: INSPECTOR C AGENCY DATE t DAVE SALZER 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION No. DEFICIENCY REFERENCE REQUIRED REQUIRED BY DATE Flo ��� a CS a W OD a � M 0P C y, U 1— 3 C Z ' t N O _ " c^ U � 0N a - X m L w on O \ ^ U 0 ova2 50 fS Cn U x aC m N d O O THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS 1Z NO LATER THAN THE DATES INDICATED PAGE OF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal-- Pink Copy: Fire District FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION FACILITY ADDRESS CITY ZIP PHONE NAME INSPECTOR AGENCY 1l / DATE DAVE SALZER 360-427-9670 X-273 MASON COUNTY FIRE MAkSHAL FD ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION NO. DEFICIENCY REFERENCE REQUIRED REQUIRED BY DATE J a a W a Ix0 Sri o w LL P groom Z 04L 0 U O N a X a7 t W Z T Cn O n '0 07 - a v+ U x a 0m N � Ci10 THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS 1Z NO LATER THAN THE DATES INDICATED PAGE OF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal — Pink Copy: Fire District FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION 'G FACILITY� ADDRESS CITY ZIP PHONE NAME INSPECTOR AGENCY DATE DAVE SALZER 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION No. DEFICIENCY REFERENCE REQUIRED REQUIRED BY DATE -e si 60-4L -11P1,44 J cdo W c o � LL ° � c U � Z y 1 1 4 001D O\+� O N m L0 x w Z ? <A O n O'A 70 � p�. v/ U x N a o � d � THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS 1Z NO LATER THAN THE DATES INDICATED PAGE OF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal—Pink Copy: Fire District FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION lJ�t�L FACILITY ADDRESS CITY ZIP PHONE NAME , INSPECTOR '' AGENCY DATE DAVE SALZER 360427-9670 X-273 MASON COUNTY FIRE MARSHAL FD ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION NO. DEFICIENCY REFERENCE REQUIRED REQUIRE BY s� M- ys tom`' LL h,►3�S �%' s �::. J/01 LU 00 00 � o F U pi Z 'v L / N � l � 3 pry O U maN /f [a L W _ Zn O 70 P ;C --`ti- x N it Q O in � O ,O a THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME,AND I AGREE TO MAKE CORRECTIONS [zi NO LATER THAN THE DATES INDICATED PAGE OF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal—Pink Copy: Fire District FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION FACILITY cIpl", e ADDRESS CITY ZIP PHONE NAME ' , - 57cnU j!L INSPECTOR AGENCY DATE DAVE SALZER 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION NO. DEFICIENCY REFERENCE REQUIRED REQUIRED BY DATE J a !d� ca G W 00 o °D LL P � C � 3 c Z oc O 6 CO N V x co a) w >-to O n O o00a l z2 0 (� U x N a 90 10 THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS NO LATER THAN THE DATES INDICATED12 PAGE OF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal--- Pink Copy: Fire District FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION FACILITY ADDRESS CITY ZIP PHONE NAME J -j INSPECTOR AGENCY DATE DAVE SALZER 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION NO. DEFICIENCY REFERENCE REQUIRED REQUIRED BY DATE cn ,1 Q W !?Y ao aCF � C H 3 � N w � a O 3 , V 0 � N CD L W Z ?N O n (n U x 2-ZI N Q C ao 0 C In O � THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME,AND I AGREE TO MAKE CORRECTIONS 1Z NO LATER THAN THE DATES INDICATED PAGE OF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal —Pink Copy: Fire District FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION FACILITY ADDRESS CITY ZIP PHONE NAME ,v ��6G` �.1/ [= 57 cal://Lm+ i. A INSPECTOR /mod AGENCY DATE f � DAVE SALZER 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION NO. DEFICIENCY REFERENCE REQUIRED REQUIRED BY DATE a cn W , Go , 000 LL °` r04 O �- V ) O \ � X m L W I Z T Vl O n 0 0 - a U x N Q ` m10 THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS 1Z NO LATER THAN THE DATES INDICATED PAGE OF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal Pink Copy: Fire District FIRE & LIFE SAFETY INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION FACILITY ADDRESS CITY ZIP PHONE NAME ieALjvv INSPECTOR AGENCY DATE DAVE SALZER 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD ITEM STATEMENT OF CODE OR WAC CORRECTIVE ACTION CORRECTION NO. DEFICIENCY REFERENCE REQUIRED REQUIRED BY DATE J Q cQ G W 'q Go Goa O� a) c Z N` N O 0 = CF M n U ci)0N m L W ?Nl O n 0 ova -- '(�� ? �C cn �m 04 Q a6a THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME,AND I AGREE TO MAKE CORRECTIONS 10 NO LATER THAN THE DATES INDICATED PAGE OF PAGES White Copy: Occupant— Yellow Copy: Fire Marshal—Pink Copy: Fire District 4 MASON COUNTY FIRE MARSHAL > Mason County Bldg.III 426 W Cedar St PO BOX 186 Shelton,WA 98584 (360)427-9670 EA 273 Permit# Mason County Fire Protection System Permit Application Incomplete application will not be accented U� Owner: 0' k b) ;k20jA Phone#: � o Mailing Address: PO 6z)X i6'b City: 411uq State: Zip: �y Site Address: 5&di City: 4State: Zip: Parcel#: g F SO Legal Description: Lien/Title Holder: �' R (N t tom," Address: 10 6QX City: X11 lik State: Zip: Contractor: orA e-s+R f f i' Phone#� / Address: $162 Rai rd �6 . City: /341%di State: tdx Zipq?51� Contractor Registration#: lames fis.0 W 5' B Expiration Date: Building Square Footage(existing&proposed): 2nd f 3ra Building Use: 0a�, Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: Wet >4� Dry New System: X Standpipe: Wet-Dry Modification: AFA: Hood&Duct.- Dry Chem: t--=- Wet Chem: Fire Pump: �---UL certified Monitoring company: &0 fd IqA <e CiAfiLPhone#: � 779 553 Contractors Bid Price: $ 6 o(r-0 o al- Plan Submittal Requirements Your plan submittal shall include the following_ • Plans shall be on standard 24"x 36"paper, drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and/or area separation walls,partitions, stairway enclosures, concealed spaces, etc. • Cut sheets and/or references for all new devices. • Location/description of all new and existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floor plan. • Electrical riser diagram showing all zones, circuits, devices, and end—of—line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$100.00. A plan review fee will be calculated at 65%of the permit fee and is due upon submittal of permit application. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire Marshal By Date: b 7 D� ,V WASHINGTON STATE PATROL FIRE PROTECTION BUREAU PO Box 42600 OLYMPIA WA 98504-2600 PHONE: (360) 570-3121 FAX: (360) 570-3136 Office of the State re August 18, 2006 Permit# Ft( c -faaC�'K� Project Name: Lexin ton Homes — Mondavia Lot 7 Reviewed by applies to plans submitted g for fire protection features 9w. 15538 NE 106t' Way -- Redmond WA Reviewed by 1610 Contractor: Final approval is awi*d to Add inspection G.R. Wilson & Associates after completion. PO Box 1499 Approval applies to plans omitted for fire protection features only Allyn WA 98524 Approved by the Authority Having Jurisdiction. Sprinkler Contact: Bill Lynch ]BY:Residential Fire Sprinkler Inc. 8102 Baird Rd NE Olympia WA 98516 Jurisdiction: Craig Haugen Mason County — Dept Processing/Inspection/Addressing 426 W Cedar Mason Cty Bldg III Shelton WA 98584 Fire Sprinkler System Plan Review. I have reviewed the plans and make these written comments. Additional notations are provided on the plans if required. (See plans) The adequacy and dependability of the water source are of primary importance and shall be fully determined, with due allowance for its reliability in the future. Plans were reviewed with current water information provided. Due to the limited supply in water pressure, changes in the field will be held to the minimum and shall be approved by the Authority Having Jurisdiction (AHJ) before changes are made. GENERAL NOTES: 1. All underground pipes serving the fire protection system, including fire hydrants shall be installed by a Washington State Fire Marshal licensed contractor with a "U" designation. Contractor stamped underground testing documents shall be provided to the local AHJ before providing water to the sprinkler system. 2. Insulation shall cover top side of piping. 3. All fire protection equipment and devices utilized in this structure shall be listed and approved by recognized testing laboratories as noted in the International Fire Code and Standards. 4. All piping shall be installed to code for drainage requirements. Drains shall be provided so that they shall handle any water that may be drained from the sprinkler system. (13D 7.2) 5. Design areas are within acceptable limits with information as provided; system shall comply with NFPA 13D. ENSURE THAT CALCULATIONS ARE CORRECT. 6. Where a fire department pump connection is not provided, the system shall be hydrostatically tested for leakage at normal system operating pressure. (13D 4.3) 7. System shall be monitored, as per the requirements of the Local Fire Department. 8. Sprinkler System shall be maintained yearly as per NFPA 25 and a copy of the NFPA 25 shall be provided to the owner by the contractor. 9. All control valves shall be provided with tamper switches that shall be wired into the fire alarm panel or locked out. (13D 7.1) (There is no Control Valve on the Riser Detail) 10. Sprinkler shall not be obstructed by lighting, or any other obstruction. Sprinkler head shall be within acceptable code distances to lighting, head diffusers, and fire alarm devices. (13D 8.2.4) 11. The system design information and all system signage shall be located at the riser. 12. Space shall be provided around pipe if riser goes through cement floor. 13. Sub-contracting of such work to persons or firms not currently licensed as a fire protection sprinkler system contractor is prohibited. 14. Spare Sprinkler Heads. A supply of spare sprinklers shall be maintained on the premises so that any sprinklers that have operated or been damaged in any way can be promptly replaced. These sprinklers shall correspond to the types and temperature ratings of the sprinklers in the property. The sprinklers shall be kept in a cabinet located where the temperature to which they are subjected will at no time exceed 100OF (380C). FINAL NOTES/REQUIREMENTS: CONTROL VALVE: (13D 7.1). 7.1.1 A single control valve arranged to shut off both the domestic system and the sprinkler system shall be installed unless a separate shutoff valve for the sprinkler system is installed in accordance with 7.1.2. 7.1.2 The sprinkler system piping shall not have a separate control valve installed unless supervised by one of the following methods: (1) Central station, proprietary, or remote station alarm service (2) Local alarm service that causes the sounding of an audible signal at a constantly attended location (3) Valves that are locked open 7.1.3 A separate shutoff valve shall be installed for the domestic water supply in installations other than those complying with Section 6_3. HANGARS: Shall comply with submitted manufacturer's instructions and be verified during field inspection. LOCATION OF SPRINKLERS: (13D 8.6) 8.6.1 Sprinklers shall be installed in all areas except where omission is permitted by 8.6.2 through 8.6.6. 8.6.2 Sprinklers shall not be required in bathrooms of 55 ft2(5.1 m2) and less. 8.6.3 Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions: (1) The area of the space does not exceed 24 ft2(2.2 m2). (2) The least dimension does not exceed 3 ft (0.9 m). (3) The walls and ceilings are surfaced with noncombustible or limited- combustible materials as defined in NFPA 220, Standard on Types of Building Construction. 8.6.4* Sprinklers shall not be required in garages, open attached porches, carports, and similar structures. 8.6.5 Sprinklers shall not be required in attics, crawl spaces, and other concealed spaces that are not used or intended for living purposes. 8.6.6 Sprinklers shall not be required in covered unheated projections of the building at entrances/exits as long as there is another means of egress from the dwelling unit. TESTING:'S�LPAJ'6. Your plan submittal for the Lexington Homes — Mondavia Lot 7 has been reviewed, with the above listed comments, final approval will be given only after comments have been satisfied to the AHJ, construction of the sprinkler system, all punch lists have been completed and approved by the AHJ, all system testing and the final walk-thru sign off inspection. Plan approval does not relieve the designer/contractor from complying with all applicable codes and requirements as adopted by local jurisdiction and the State of Washington, nor does it abrogate the requirements of the requirements of other authorities having jurisdiction. 1. The AHJ listed above (Craig Haugen) shall be notified (360) 427-9670 at least one week prior for both the cover inspection and final inspection. 2. Enclosed is a copy of Sprinkler System Installer Certification; this shall be signed and dated before the final acceptance testing is started. Additional comments may be made as the project moves forward. Chief Deputy State Fire Marshal Lance Talley Deputy State Fire Marshal Barbara McMullen Washington State Patrol / Fire Protection Bureau 210 11th Ave SW Olympia WA 98504-2600 (360)570-3121 Model Cauto RFC43 (SIN RA0612) and ion RFC56 (SIN RA0914) Flat Concealed Residential Sprinkler Read Carefully! Installation Instructions General Instructions 1. Do not pull on the deflector when moving Model RFC43 Cover plate: 135°F(57°C) and RFC56 Sprinklers from the shipping carton. Sprinkler Temp. Rating: 165°F(74°C) 2. Install sprinklers after ceiling is in place. Max. Pressure: 175 pslg 3. Never apply paint or any other coating to sprinkler or Max. Ceiling Temp.: 100°F(38°C) concealed sprinkler cover plate. 4. Do not install concealed sprinklers in ceilings which have When in doubt as to ceiling temperature, measure positive pressure in the space above,and do not cover with an accurate thermometer. the cup vent holes. An open plenum space must be Installation above the sprinkler cup. Model RFC43 and RFC56 sprinklers are to be 5. Use the proper wrench(Figs. 1 and 2)to install sprinklers. Face of sprinkler fitting to ceiling is 2"for the RFC42 and installed in ceilings with a plenum space above that 2%6"for the RFC56. Ceiling hole diameter is 2%". does not have positive pressure. In addition, inspect 6. Final adjustment of each cover is made by hand turning all sprinklers after installation to ensure that both the the cover plate in the clockwise direction until it is tight gap between the cover plate and ceiling and the (4) against the ceiling. slots in the cup are open and free of any air flow Approval Organizations impediment. After a 2%inch diameter hole is cut in the ceiling,the Underwriters Laboratories Inc. and sprinkler is to be installed with the proper wrench UL certified for Canada(cULus) (Figs.1 and 2). When installing a sprinkler,the wrench I ULI Listing Category: is first positioned into the sprinkler/cup assembly and Residential Automatic Sprinklers around the sprinkler frame. The Wrench must bottom ULI Guide Number: out against the cup in order to ensure proper, safe VKKW installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench Models RFC43 and RFC56 are UL Listed Residential from the sprinkler/cup assembly, care should be Sprinklers and are intended for use in accordance with taken to prevent damage to the sprinkler. DO NOT NFPA13 Paragraph 4-3.6 in residential portions of any WRENCH ON ANY OTHER PART OF THE occupancy, in one and two family dwellings and mobile SPRINKLER/CUP ASSEMBLY. MODEL RFC43 AND homes,(NFPA-13D), and residential occupancies up to RFC56 CONCEALED SPRINKLERS MUST BE four stories in height(NFPA-13R). The letters "RFC43", INSTALLED ONLY WITH 1350F RATED COVERS. or "RFC56", temperature, K factor, and year are stamped on the deflector. Technical Data r_ - Minimum Required Nominal Orifice Size K Sprinkler Maximum Sprinkler Discharge Minimum Distance Model Spacing Distance to - between Sprinkler In.(mm) Factor (ft-) Wall(ft.) Flow Press. 00 (9 (15) - 4.3 12 x 12 6 12 7.8 8 5) 4.3 14x14 7 13 9.1 8 RFC43 1/2"(15) 4.3 16 x 16 8 13 9.1 8 Yi'(15) 4.3 18 x 18 9 18 17.5 8 1/2"(15) 4.3 20 x 20 10 21 23.8 8 '/2"(15) 5.6 12 x 12 6 26 21.6 8 RFC56 1/2"(15) 5.6 14 x 14 7 26 21.6 8 1/2"(15) 5.6 16 x 16 8 26 21.6 8 The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 CA-141 Rev A • Model F1 Res 44 SWC 4'to 12 (1O1.60mm To 3O4.8Omm1 Fate Of Fat%^9 PUSH ON COVER. THEN - � To Won Done Ss TURN TO ADJUST UNDL TIGHT AC.AWST WALL if I'X 112'Red=et i! ,� '-- Recommemhd ,1"r Won Hole 2 5/16- 2 5/8' (57.94-1 T -{--- - - - 3 5/16- y. [66,68mmJ D:o. i [84.14mm] TURN COLLAR UNT& '' 1 TIGHT AOARIST SPRWKLER .._ 1 21/32' WRENCH BOSS- [15.8&nm] 13Y607 1/2'[13.7Omm] Adj-f.m t F1 RES 44 SWC Fig. 5 Technical Data: F1 Res 44 SWC Sprinkler coverMaxSprinkler Thread TemP- Rahng P- Max.Pressure Ambient Temp. K Length StEe Rate psi(bar) o f Factor Inch(mm) OF OC OF °C MY'NPT 155 68 135 57 175(12) 100 38 4.4 2.45(62) R1/2 RA„ Max.Sprinkler kler Spacing Ceiling-to- Fkmr Pressure Identification Deflector gPm(LPM) Ps'Qw) Number(SIN) Inch mm 12 x 12 3.6x3.6 13 49.2 8.7 0.60 14x14 4.3x4.3 14 53.0 10.2 0.71 16 x 16 4.9x4.9 (1 4-6 17 64.3 15.0 1.1 16 x 18 4.9x5.5 19 71.8 18.7 1.13 16 x 20 4.9x6.1 23 87.1 27.4 1.89 R3531 12 x 12 3.6x3.6 14 52.9 10.2 0.71 14 x 14 4.3x4.3 6-12 15 56.7 L20 .7 0.81 16 x 16 4.9x4.9 (152-305) 18 68.1 6.8 1.16 16 x 18 4.9x5.5 20(75.6 .7 1.43 7. INSTALLATION AND MAINTENANCE INSTRUCTIONS - �� SYSTEM SENSOR- WFDT/WFDTH Vane-type 3825 Ohio Avenue,St.Charles, Illinois 60174 1-800-SENSOR2,FAX:630-377-6495 Waterflow Detectors www.systetnsensor.coni $pecH ications Contact Ratings: Two sets of SPDT (Form C) 10Aa 125/250 VAC ti; 2.5ACa? 24VDC__ _ Triggering Threshold Bandwidth (Flow Rate): 4 - 10 GPM Static Pressure Rating: 250 PSI (Max.) Dimensions, Installed: WFDT - 45/i6"H x 3 /4"W x 63/4"D WFDTH - 45A6"H x 3°%6"W x 63/4"D Operating Temperature Range: 32-F- 120'F (0-C -49°C) Shipping Weight: 2.6 lbs. Enclosure Rating: WFDT - NEMA Type 4, as tested by Underwriters Laboratories, Inc. (UL) UP561__. WFDTti - Indoor use only, as tested by UL (1P10) The WFDTH can be installed between 2x4 stud wall-construction. U.S. Patent Number: 5,213,205;4,782,333; 3,845,259 knportent Approximate Tee Depth Requirements Please Read Carefully And Save (see Figure 1) This instruction manual contains important information Tee Depth Threaded Sweat Poly B cPVC CPVC/spears CPVC/Central about the installation and operation of waterflow deter- 1 x 1 X 1' Vis 1314' N/A 2'/4' 2'%Z' 23/16- 1'/4 X V/4 x 1' 21/2' 2'/s' NIA N/A NIA N/A tors. Purchasers who install waterflow detectors for use by 02 X Vh X 1' 23/4' 2/4' Ve N/A NIA NIA others must leave this manual or a copy of it with the user. 2 X 2 X 1� s'/r n: WA WA NIA N/A Read all instructions carefully before beginning. r 1_Mounting di ons; ACAUTION tin Use vane-type waterflow detectors in wet-pipe CWMTH) only. DO NOT USE IN DRY-PIPE, DELUGE, OR PRE- ACTION SYSTEMS. The sudden inrush of water in such systems may break the vane off or damage the mechanism. Do not use in potentially explosive atmospheres. Do not leave unused wires exposed. 41AC Principles OF Operation a waterflow detectors mount to water filled ni es TaeA*00 / M.9F11� T�a�' Vane-type -Lp: i Tee am mpsm a Fmn96 in sprinkler systems. Waier flow in-the-pi-pi-de flects a vane. Deflection of the vane produces a switched output, usually after a s ecified dela . Tee Dew' Tea FNWg All WFDTs have a pneumatically controlled mechanical TaW delay mechanism. Delays are noncumulative; they reset if 1`65aV� the flow of water stops before the entire delay has elapsed. w0126(N) All detectors will activate on a sustained flow of water Installation Quidelines greater than 10 gallons per minute (gpm) but will not acti- Before installing any waterflow alarm device, be thorough- vate if the flow rate is less than 4 gpm. ly familiar with: Compatible Pipe Tmm/Risers NFPA 72: National Fire Alarm Code The WFDT and WFDTH fit i"to Ph"NPT threaded ferrous NFPA 13: Installation of Sprinkler Systems and brass, 1" to 2" sweat brass, Ilff polybutylene plastic NFPA 25: Inspection, Testing, and Maintenance of and 1" pvc plastic tees having a 1" threaded NPT branch Water-based Fire Protection Systems NFPA 13D. - Standard for 1 and 2 Family Dwellings and (see Figure 1 and chart for recommended tee depths). For Manufactured Homes 2" cast and malleable threaded tees use 2" paddle (p02- NFPA 13R: Standardfor Multi-family Dwellings 0023-000) provided. N770-05-00 i 156-0480-OIOR . , • , DOUBLE CHECK ASSEMBLY sACKFLOW PREVENTION — Characteristics Physical Properties e Size 1/2". 34 1". 1-1/4 , 1.112".2" ® _ r Max WorKing Pressure 1 75 PSI (1200 KPa) Hydrostatic Test Press. 350 PSI (24t'0 KPa) Ternperarwe Range 320F to 140`F(0OC to 6WC) End Connections Thraadeti ANSI 82.1 1 Materials Valve Bcdy Bronze Elastomers Sihcone MODE-850(1n•_2")Doe aLE,CHECK A�0',W 1LY Springs Stainless Steel Agency Compliance • ANSI/AWWA Conformance (C510-0:2) Application Non-Health tiazari; • ASSE Listed (Std 1015) 1 • CSA Options • Approved by the Founciation for Cross Connection / \ Control and Hydraulic Research at the University of Wye -Strainer Soutnem California. ! Model F,50 (1/2" - 211) Flow Curves 1/2 1-1/2" 20 .-. 20 -f ! ul N 1 i 4, 15 10 s 10 5 4 9 15 18(GPM) 0 20 40 6 �� 20 C5 _( a 15 a 15 � tp 10 - 10 -9 0 5 ..,, m 59 1 ` 1 o � o 0 5 10 15 20 25 30(GPM) 0 30 60 4 120 150 Ito(GPM) 1" 20 Installation Recommendations c� 15 J i I r � ' - 10 ,• 12"Mn:mum Cwarance to Fixeb S;:utture 0 D 10 I !.20 M) 30 40 50 60(GP 4 15 Minimum 10 m 5 Row MODEL 00(112'-20) m � pVutcn;•Instaitatfon . = 0 ..� 0 20 40 60 80 100 120(GPM) • I N K L E R S Y S T E 1W S M 0-'qV I T • SSM/SSV Series SYSTEM Alarm Bell* Models Available- UL/FNI Models SSM24-6 r� > SSM 24-8 SSM 24-10 SSV 120-6 SSV 120-8 SSV120-10 ULC/Canadian Models SSM 24.6A SSM 24-8A SSM 24-10A SSV120-6A SSV120-8A SSV 120-10A Weatherproof Back Box WBB Product Overview Approved for indoor and outdoor use System Sensor's SSM and SSV series bells are low current, high decibel notifi- Low current draw cation appliances for use in fire and burglary systems or other signaling appli- cations. High dB output Reliable Performance. The SSM and SSV series provide loud resonant tones. Three sizes available 6", 8", 10" The SSM series operate on 24VDC and are motor driven, while the SSV AC and DC models series operate on 120VAC utilizing a vibrating mechanism. DC models are polarized for use with Simplified installation. For indoor use, the SSM and SSV series mount to a supervision circuitry standard 4 inch square electrical box. For outdoor applications, weather- proof back box, model number WBB, is used: Mount directly to standard 4" square electrical box The SSM and SSV series come pre-wired, to reduce installation time. The SSM series incorporate a polarized electrical design for use with,supervision circuitry. Engineering Specifications Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome L ULC O strikers and operating mechanisms. Gongs on said bells shall be no smaller FM than nominal 6"/8"/10" (specify size) with an operating voltage of 24VDC or S4011 CS549 30STM 05255 120VAC (specify by part number). Bells shall be suitable for surface or semi- flush mounting. Outdoor surface mounted installations shall be weatherproof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4"square electrical box having a maximum projection NF A of 2%". Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor approved 71351209:164 331-01-E 7135-1209:100 use by Underwriters Laboratories and the California State Fire Marshal, and approved by Factory Mutual and MEA. ® INSTALLATION ERICO USED FOR PVC PIPE ONLY. INSTALLATION INSTRUCTIONS MODEL # 108 SERIES TWO HOLE STRAP HANGER 0 PIPE HEAD HEXDIAMETER(0) t SCREW 1. SNAP PVC PIPE INTO HANGER. DIMPLES HOLD PIPE _ IN PLACE. 2. MOUNT HANGER TO UNDER SIDE OF BEAM WITH SCREWS PROVIDED. 3. MAY ALSO BE USED ON TOP SIDE OF BEAM. PART NO. PIPE DIA. (SEE BELOW) 1080075EG 3 4" 1080100EG 1" PIPE 1080125EG 1 1 4 HEX HEAD SCREW DIAMETER() 1080150EG 1 1 2 1080200EG 2" SCREWS PROVIDED LENEIM, WARNING: 1. Caddy*Fasteners that are manufactured using spring sled components may be used only in a non—corrosive indoor environment. Only non—spring steel fasteners that hmt protective coatings may be used otherwise, as specified_ 2. Fosteners must be used only in the manner depicted in the illustrations that accompany it and must not exceed static load ratings noted. 3. Fasteners are designed for use with a variety of industry standard building materials, structural shapes. and mechanical components. for the fastener to work properly, these items must meet the appropriate industry standards. (Examples.ANSI, AISC, AISI) 4. The buyer and/or installer is responsible for. a. Application in conformance to local codes. b. The integrity of structures to which the fasteners is attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer. c. Using appropriate industry standard hardware os noted above. S. Failure to observe these specifications may cause product malfunction resulting in property damage or bodily injury. ERICO Products at the lime of shipment art ■orranted to conlarm to any applicable written description furnished to the Buyer by ERICO, and to be free from defects in material and workmanship. NO OTHER WARRANTY, WHETHER EXPRESS OR IAIPUED. (INCLUDING ANY WARRANTY OF WEP.CNANT—ABIUTY OR FITNESS), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCT. SAFETY INSTRUCZNS: All safety regulations required by the job site must be observed. Special attention should be given to the following instructions. While worldng or on the job site: r+►r✓arr+ r.rr +rrrr rr-.r rr� TECHNICAL SUPPORT PHONE: (800) 25-CADDY 02000 ERICO, INC. CFS296A PRINTED IN U.SA (1-800-252-2339) ' of l iESIGN CALCULATIONS ( NFPA 13D) Sheet NO! Date: d ESIVENTIAL FIRE SPRINKLER SYSTEM By: ctivity i�Dlo / / �7Floor Lenel z-��Gud ,roject Name�y Av&./ -]/ ,%�-3 . ' /�6T, (Ulev. of Spkrs: project Location- 1 m. at: p.s.i. Locations��•�- �?�I�GI 'available rater Supply: g'p' �- - �e, �fc►_�3 ���� , Max Sprinkler Spacing: ft_ X _�_ ft_ Sprinkler I.D: e� £� �- - -- CALCULATIONS ONF.-SPRINKLER DESIGN: 2 Sprinkler flow: System demand gpm Min_ Flow: gpm: Min. press:-5� psi TWO-SPRINKLER DESIGN! Min. Flow: ,-2-fi gpm- Min. press: / psi PIPING (2 spkr. flow = gpm) TOTAL UNIT TOTAL DIA LENGTH X FR LOSS' FR LOSS Type of Piping: Steel (Sch_ 40) U37O y1-lePl1 •� f�7 G,Gam` Copper K, L, M (Circle one) / -�— Plug 151, �l3 FITTINGS. 6 .VALVES .(2-spkr. flow = gpm) CALCULATIONS UNIT TOTAL UNIT TOTAL T 1 Sprinkler flow: System demand = �3 _ gpm IP b . ' YPF. QT7 X � LBN . EQ LB1�- 04 �®• FP LOSS PIPING ( 1 spkr flog) _.L�._� Z � JD � TOTAL X UNIT _ TOTAL ' DIA. LENGTH FR LOSS FR LOSS -eV. , Plus i5t 3/ METFR FRICTION TOSS (size=/ W) .4� FITTINGS 5 VALVES ( 1 spkr flow) SPRINKLER PRESSURE REQUIRED q, /d . FT.EVATION HRAD LOSS (/Yft X .434) DTA_& Unit TOTAL UNIT y TOTAT. TOTAL SYSTEM PRE99URS nF24AND TYPE QTYX X EQ.LEN.EQ_LEN_ FR-LOSS FR.LOSS TOTAi, SUPPLY PRP.SSURF. AVAILABLE .1�D vfi — --�-- -�-- ss �Z NORTHWEST RESIDENTIAL, FIRE SPRINKLER INC —�.jc A .J 8102BadWI Olympia, WA 9954.6 (3( 754-6475 METER FRICTION LOSS (Size�/w ) Cont or's Reg. #NWRESFS085BA SPKR PRESSURE REQUIRED v ET,EVATION HEAD LOSS (/p f t X 0.434) TOTAL SYSTEM PRESSURE DEMAND �� I TOTAL SUPPLY PRESSURE AVAILABLE DESIGN CALCULATIONS ( NFPA 13D) Sheet No: ' of l D -- IESIDEIyTiAL FIRE SPRINKLER SYSTEM Date: By: Activity 119- Project Name7����%�j�P�j- i��IZ)�1"'��y 8�/'� Z7'07Floor Levels �TGyII lev. of Sgkrs: Project Locationj ?$��, /7_5 m. at: p. .i. Locations��.�� a rZ Q��,►v)'�' Available Water Supply! 9-P• �Zgs ���,� Max Sprinkler Spacing: ft. X �_ ft. Sprinkler I.D: �y� Q �- CALCULATIONS ONE-SPRINKLER DESIGN: gPm� Min. press ps 2 Sprinkler flow: System demand = gPm Min. Flow: : f i TWO-SPRINKLER DESIGN: Min. Flow: gpm: Min. press: , / psi PIPING (2 spkr. flow = gpm) TOTAL UNIT TOTAL DIA LENGTH X FR LOSS' FR LOSS Type of Piping: X CPVC PVC '— Steel (Sch. 40) Copper K, L, M (Circle one) — Plug FITTINGS. 6 .VALVES .(2-spkr. flow = gpm) CALCULATIONS UNIT TOTAL UNIT TOTAL 1 Sprinkler flow: System demand = 9Pm TYPE. QTY X (?Q LHN . EQ LEN J16fi® Fl2 LOSS 1d67 1 Q PIPING ( 1 spkr flow.) L � � • 7. TOTAL X UNIT TOTAL ��-DIA. LENGTH FR LOSS FR LOSS ? _/ ���Plus 15% ICTION TOSS (size=FITTINGS & VALVES ( 1 spkr flow) R PRESSURE REQUIREDN nRAD TOSS G� ft X .434) DTA.6 Unit TOTAL tTNIT TOTALSTEM PRESSURE DEMAND TYPE QTYX EQ.LENXEQ_LEN_X FR.LOSS FR.LOSS PPLY PRESSURE AVAILABLE .hD NORTHWEST RESIDENTIAL FIRg SPRINKLER INC Olympia, WA 98546 (3W 754-6475 METER FRICTION LOSS (Size } p O Cont r�r}or's Reg. /NwPBSFS085BA SPKR PRESSURE REQUIRED g,� y �W1410*� ELEVATION HEAD LOSS (/D ft X 0.434) 5 f twit or TOTAL SYSTEM PRESSURE DEMAND TOTAL SUPPLY PRESSURE AVAILABLE le ��Yncn -0