HomeMy WebLinkAboutBLD2001-01133 Propane and Outlets - BLD Permit / Conditions - 10/29/2001 Inspection Line (360)427-7262
MASON COUNTY DEPT. OF COMMUNITY Phone: (360)427-9670, ext. 352
DEVELOPMENT 2 —i C- /
lip
Mason County Bldg. 3 426 W. Cedar P.O. Box 186
Shelton, WA 98584 MECHANICAL PERMIT
77
- 1133
OWNER: LARRY MARTIN
CONTRACTOR: RECEIVED: 10/29/01
SITE ADDRESS: 6028 W SHELTON MATLOCK RD SHELTON ISSUED: 10/29/01
PARCEL NUMBER: 420163290012 EXPIRES: 4/29/02
LEGAL DESCRIPTION: TR 1-B OF SW SW TR 2 OF SP #2711 #624396
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
PROPANE TANK, OUTLETS SHELTON MATLOCK ROAD APPROX 6 MILES TO CHAPPLE CROSSING
TO THE RED OX RANCH TURN RIGHT GO APPROX 1/4 MILE DOWN
DRIVEWAY, GO PAST 3 HOUSES ON THE RIGHT, CONTINUE ONTO THE
General Information Mechanical Fixtures FEES
i
Type of Use: MH Insp. Area: Type Qty. Type By Date Amount Receipt
Type of Work: MEC Fire Dist.: Gas Outlets 1 Mechanical Fee KC ini94rni 7-21 .-An r;77a4
Propane Tank 1 Mechanical Base Fee KC in»ainl rn r,7740
Total $44.80
BLD2001-01133 Please refer to the following pages for conditions of this permit. 1 of 3
CASE NOTES FOR
BLD2001-01133
CONDITIONS FOR
BLD2001-01133
1) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and
legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site
inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or
X contractor fail to the address on site prior to requesting inspections.
2) Proposed structure or portions thereof with an projection over 30" in height from grade line, must maintain a 5'separation distance between adjacent
structures and that furthest projection. X %-
3) All propane tanks must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All propane tanks filled on
site must be located a minimum of 10'from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system
air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane
tanks less than 125 gallons must also be located a minimum of 5'from any building opening (foundation vents, windows, doors etc), property line or
easement. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed.
X
4) All propane tanks must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All Propane tanks between
125 and 500 gallons must be located a minimum of 10'from any building, property line, public way, possible source of ignition (electrical outlets,
electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. If a propane tank is exposed to
probable vehicular damage, protective bollards must be installed.
X C)r�
5) All propane tanks must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All propane tanks must
meet the installation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks.
X
6) Fuel piping shall be inspected after the installation of gas piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the
time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system
shall not be used until the final inspection has been performed and approved by a Mason County building inspector.
X 9=
7) Owner/applicant must obtain a seperate per 't for the placement of any size propane tank serving a fixed appliance within a dwelling structure or unit
prior to the placement of the tank. X_
BLD2001-01133 Please refer to the following pages for conditions of this permit. 2 of 3
8) , The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to
&Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams,
wcrinnds, slopes, etc.) If you think such Natures exist on or nearby your property, please contact the Planning Department so that exact setback
requirements can be determined. X
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period
of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection
must be approved before building can be occupied.
OWNER OR AGENT: Q-� _ �, DATE:
I
BLD2001-01133 Please refer to the following pages for conditions of this permit. 3 of 3
PERMIT NO.:
MASON COUNTY
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W.Cedar/P.O.Box 186,Shelton,WA 98584
Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968
APPLICANT INFORMATION \^� . CONTRACTOR INFORMATION
Owner F ,� cy Tac �n 1DAA rl , _ Contractor Name l oP?A I r >S
Mailing Address V�,, t C,, k Prt Mailing Address
City J Y j jZ y% State_Wg.Zip Code City State Zip Code
Phone(__, ),tt-y _ oaSiOther Ph.( _;�, ) L22 -cd 1,Q9 Ph.( Other Ph.0
Lien/Title Holder t s,�a S , �1 , „� I Contractor Reg. #
Address n Expiration
SEPTIC INFORMATION-Connect to New Septic Existing Septic Connect to Sewer System Name of
Sewer System
PARCEL INFORMATION-12 digit Tax Parcel No. 1 of u i !v /_ / Fire District
Legal Description If
_
Site Address(Please include street name, street number and city) (an;zV U t, S F)
Directions to site
Is your property within 200' of the following: Body of Water(Name) '�1 r Saltwater
Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or
Bluffs
TYPE OF JOB New Add Alt Repair Other Use of Building nl
Location of Fixtures/Units 1st Floor 2nd Floor Basement Garage Closet
PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS Fuel Type: Electric
Type of Fixture No. of Fixtures Fees LPG Natural Gas Heatpump
Toilets Type of Unit No. of Units Fees
Bath Basins Furnace
Bath Tubs Heatpumps
Showers Vent Fans
Water Heater Propane Tank �_ 10%:
Laundry Wsher Gas Outlets
Sinks Wood/Gas/Pellet Stove _ —
Dishwasher Direct Vent?
Other Other
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
A FLOOR PLAN AND PLOT PLAN MAY BE REQUIRED DEPENDING ON THE TYPE OF FIXTURE/UNIT.
NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF
CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the
information provided is accurate and grants employees of Mason County access to the above described property and structures for review and
inspection of this project. Acknowledgment of such is by signature below:
OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a
Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance
requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work
conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without
approval. first obtaining approval.
r -
X Date X Date
FOR OFFICIAL USE BEYOND THIS POINT
Accepted by Date Submittal Amount Due Receipt No.
VIEPATi'1`MI%TAL fi 1(I W AP F2r7V � d M1EIED CfANCliTI(?N CC9FtE5
Building Department rQ O//j� S�� F PqA by L,t X
Occ Group Type Constr.
Planning Department
Other
Other
FEES
Permit Fee Site Inspection
Plan Review Fee UFC Plan Review Fee
Plumbing& Base Fee Other
Mechanical&Base Fee Other
Wood/Gas/Pellet Stove Fee Pre-Paid at Submittal ( )
Violation Fee TOTAL FEES
MECtiMCAL MOBILE HOME
Paibbom
FoodrQ3-Setback date date
by a
Gas Ptpirq
up
F, n WalI3 date � ,
INSULATION Fk1aI
kisulad Floors databy
date by date byFIRE DEPT.
FRAMING Wan3 date by
date by date by OTHER
PLUMBING AWc
Growxdwork date by
date WALLBOARD NAILING
D.W.V. data by
date by FINAL INSPE9TION f %
Water Lino1� /Y `
data by data /��^'�� - T;'1 data by
4—in e-
r'1 n n,uh 7'[.s t' /�SSG✓� S /� �JS i Z 1hs
Q,n (�GGL
z Cr�-
f � hey—
2u
_: