HomeMy WebLinkAboutBLD2017-00731 Bridge - BLD Application - 7/31/2017 MASON COUNTY COMMUNITY SERVICES
PERMIT ASSISTANCE CENTER: Peruuit No: --Q 07 3 1
•BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL
{ 615 W.Alder Street,Shelton,WA 98684
Phone Shelton:(360)427-9670 ext 352•Fax:(360)427-7798 PhoneREC EI /
eelfalr.(360)275-4467•Phone Elma:(360)482-5269 �/ D
BUILDING PERMIT APPLICATION JUL 31 2017
PROPERTY OWNER INFORMATION: CONTRACTOR INFO 'ftd(*er Street
NAME: J Oho 13&"Ot1 NAME:
MAILING ADDRESS: ZO L Vh 0 MAILING ADDRESS:
CITY: (216 H(L•MOIL— STATE: W k ZIP: 3_-,Z CITY: ST� lu
PHONE#1: 3Lt0-50o1�3Str3 PHONE: t= `` -
PHONE#2: Z5b-ZZ$- ZA�Iq EMAIL :
EMAIL,:_ K0.�a*.5 i L l a.5(�y� iwsk. A J 1u-- L&I REG# EXP.
PRIMARY CONTACT: OWNER CONTRACTOR❑ OTHER❑
NAME IT0110 O&L600 YX EMAIL id . nI ISd� IQrtllPi.MAILING ADDRESS 01e, CITY STATE ZIP
PHONE
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 12Z I Lo^ ZLl—0003,0 ZONING
LEGAL DESCRIPTION SAbbreviated) P#oP 6"V e4 FIRE DISTRICT
SITE ADDRESS NI CITY
DIRECTIONS TO SITE ADDRESS 61- RouTt_ 36 Z iyt i t.aE Pour Z. 1
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YESX NO❑ W055 H�y
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF❑ STREAM
TYPE OF WORK: NEW ❑ ADDITION❑ ALTERATION❑ REPAIR❑ OTHER �I�l-t1G C�It.V
USE OF STRUCTURE(Residence,Garage,Commercial Bldg,
IS USE: PRIMARY❑ SEASONAL ❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS
HEATED STRUCTURE? YES(Whole Bldg) ❑ YES(Part[s]of Bldg] ❑ NO❑DESCRIBE WORK bibtl(a& O✓& ( Z&1�V_ *Bia QIrw. t— pV oDU—
SQUARE FOOTAGE: (propose+existing)
I ST FLOOR sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft.
GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: ► J Pr *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL IIEALTH: 0 (Fr
SEWAGE/SEWER SOURCE: SEPTIC ❑ SEWER❑ / NEW ❑ EXISTING❑
PLUMBING IN STRUCTURE? YES ❑ NO❑ If yes, attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES❑ NO❑ EXISTING SQ.FT.
EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permittapplication becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
x 3!Lw 17
Signatu oOWNER(Must be siane by the OWNE date
DEPARTMENTAL REVIEW . APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL —
PUBLIC HEALTH
eon Cov
Mason County Community Services
Building Division
SPECIAL INSPECTION & 615 W Alder Street
- _ - Shelton, WA 98584
,Ssa TESTING AGREEMENT 360.427.9670 ext. 352
www.co.mason.wo.us
(All references are per the 2015 International Building Code)
Project Name: John and Karen Nelson E State Route 302 Belfair Residential Vehicle Bridge
Project Address: State Route 302 Mile Post 2.1
Building Permit Number: BLD2017-00731 Date Issued: Z-y 26/-7
BEFORE A PERMIT CAN BE ISSUED: The registered Design Professional in responsible charge shall fill out the Agreement
and include the name and address of the company or inspector. Two (2) copies of this form are to be submitted to the
County prior to the issuance of a building permit. If changes are made as to who will perform the special inspections a new
form shall be submitted and turned into the Building Permits&Inspections Division for approval.
STATEMENT OF SPECIAL INSPECTIONS: In addition to this Agreement, a "Statement of Special Inspections" shall be
provided per IBC 1704.3. This Statement shall be made as part of the approved plans, and be placed in a conspicuous
location,such as the first page of the construction plans or the first page of the structural sheets.
SPECIAL INSPECTORS:All special inspectors shall be approved by the Building Division prior to performing any duties. The
special inspector shall provide proof of certification as a special inspector for each inspection item and be licensed by the
State of Washington.
SPECIAL INSPECTION REPORTS: Special inspection reports are to meet the requirements of IBC 1704.2.4. Copies of each
report are to be sent to the address listed in the letterhead noting the Project Address and Permit Number. A final report
shall be submitted stating that all special inspection and structural testing items were completed and are in conformance
with the approved design drawings and specifications. Items not in conformance, unresolved items,or any discrepancies in
inspection coverage (i.e. missing inspections, periodic inspections when continuous was required, etc.) shall be specifically
itemized in the final report.
Areas requiring special inspection: Name of Agency: Address&Contact Information
❑ Unapproved Fabricators(IBC 1704.2.5)
Other than Structural Steel(IBC Table 1705.2.2)
❑ Steel floor&roof decks
❑ Welding of reinforcement
❑ Cold-formed steel
Structural Steel John D. Nelson, 2011 Drummond Dr. NW
❑ Welding(Per N5.4 of AISC 360-10) WA Civil PE#39603 Gig Harbor,WA 98332
❑ Details(Per N5.7 of AISC 360-10) 360-509-3563
X High-strength bolts(Per N5.6 of AISC 360-10)
John D.Nelson, 2011 Drummond Dr. NW
Concrete Construction(per IBC Table 1705.3) WA Civil PE#39603 Gig Harbor,WA 98332
X Reinforcement,embeds,anchors 360-509-3563
❑ Formwork
❑ Materials
❑ Shotcrete
❑ Post-tensioned/Pre-stressed Concrete
❑ Erection of precast concrete
Page 1 of 3
Mason County Community Services
Building Division
SPECIAL INSPECTION & 615 W Alder Street
- Shelton, WA 98584
IR54
TESTING AGREEMENT 360.427.9670 ext. 352
www.co.mason.wa.us
Areas requiring special inspection: Name of Agency: Address&Contact Information
Masonry Construction(IBC 1705.4)
❑ Prior to Construction(Article 1.15,TMS-602)
❑ As Construction Begins(Article 1.19.2,TMS-402)
❑ Prior to Grouting(Table 1.19.2,TMS-402)
❑ During Construction(Per TMS-402&TMS-602)
Wood Construction
❑ High-Load Diaphragms(IBC 1705.5.1)
❑ Wood Trusses>60ft(IBC 1705.5.2)
John D.Nelson, 2011 Drummond Dr. NW
X Soils(IBC Table 1705.6) WA Civil PE#39603 Gig Harbor,WA 98332
360-509-3563
❑ Driven Deep Foundations(IBC Table 1705.7)
❑ Cast-in-place Deep Foundations(IBC Table 1705.8)
❑ Helical Pile Foundations(IBC 1705.9)
❑ Sprayed Fire-Resistant Materials(IBC 1705.13)
❑ Mastic&Intumescent Coatings(IBC 1705.14)
❑ EIFS(IBC 1705.15)
❑ Fire-Resistant Penetrations(IBC 1705.16)
❑ Smoke Control(IBC 1705.17)
❑ Structural Steel(IBC 1705.12.1&AISC 341-10)
❑ Structural Wood(IBC 1705.12.2)
Page 2 of 3
�--. IL%
t�0�x COa�aA
Mason County Community Services
Building Division
SPECIAL INSPECTION & 615 W Alder Street
Shelton, WA 98584
IF54
TESTING AGREEMENT 360.427.9670 ext. 352
www.co.mason.wa.us
❑ Cold-formed Steel(IBC 170S.12.3)
❑ Mechanical&Electrical Components(1705.12.4)
❑ Architectural Components(IBC 1705.12.5)
❑ Storage Racks(IBC 1705.12.7)
❑ Other (IBC 1705.1.1)
❑ Other (IBC 1705.1.1)
Declaration by Architect/Engineer
I, the design professional in responsible charge for this project, declare that the
above listed special inspection and structural testing items are required for this
project in accordance with IBC Chapter 17.
Sr 07-44-36-0240'
Date
Declaration by Owner
I,the Owner of the project,declare that the above listed firm(s)or individual(s)are hired by me to perform
special inspections and structural testing for the project pursuant to IBC 1704.2.
Signature - Date
CONTRACTOR RESPONSIBILITY: Each contractor involved with the construction of wind or seismic force-resisting
systems shall comply with the requirements of IBC 1704.4. The contractor is responsible for providing the
special inspector access to approved plans and contract documents at the job site. All special inspection records
shall be retained at the job site by the contractor and shall be made available to the Building Department upon
request.
Declaration by General Contractor
I, the General Contractor of the project, agree to comply with the "Contractor Responsibility" items noted
above. ��✓
2017.12.04 07:48:03-08'00'
Signature Date
Page 3 of 3
PLAN N�N G• ~�� GENERAL STRUC"I'URAL NOTES
GENF.RAI,
ALL SETBACKS ARE MEASUREC THIS BRIDGE CONFORMS TO TI1E ASSI-ITO LEDS BRIDGE DESIGN STANDARD SPECIFICATIONS FOR
- `- HIGHWAY BRIDGES AND WSDOT BRIDGE DESIGN NIANUAL M23-50.16. ALL OSHA AND
FROM THE FURTHEST i WASHING"fON LScI REGULATIONS SHALL BE COMPLIED WITH DURING CONSTRUCTION.
PROJECTION OF THE BUILDING DESIGN LOADS
O'C S O� DESIGN LIVE LOAD = HL-93(72KIP PLUS IMPACT LOAD)
SO DESIGN MAXIMUM LANE MOMENT = 114.4 KIII-FT
DESIGN DEAD LOAD = 0.64 KIP/LF
ve DESIGN LOAD ON SILL = 56.2 KIPS
MAXIMUM DEFLECTION = 0.0171N< L/800
FOUNFATIONS
�+
NATIVE SOIL BEARING PRESURE IS LIMITED TO 3000 PSF FOR GM SOIL TYPE USING UNIFIED SOIL
rop s CLASSIFICATION SYSTEM. BOTTOM OF ALL FOOTINGS TO BEAR ON NATIVE,INORGANIC
UNDISTURBED SOIL A MINUMIM OF 1.0 FT BELOW THE EXISTING GRADE ON SELECT,
COMPACTED,STRUCTURAL FILL.COMPACTED TO APPROXIMATELY 90%MAXIUMUM DENSITY.
PL oe
PRECAST CONCRETE
MASON COUNTY DCD PLANNING ATTAIN MINIMUM COMPRESSIVE STRENGTHI OF 4000 PSI AT 28 DAYS. CONSTUUCTION TO BE IN
C� ACCORDANCE Wffll ACI 318"PART 2-STANDARDS FOR TEST AND MATERIALS"."PART 3-
SITE PLAN REQUIRED TO BE ON SITE a CONSTRUCTION RCQIEMENTs",".AND CIIAPTER 16--PRECAST CONCRETE".
CHANGES SUBJECT TO APP AL
REIENFORCEMF.NT
Date ALL STEEL REBARS SHALL CONFORM TO ASTIVI A615 GRADE 60. ON-SITE WELDING INCLUDE
BY aZ STRINGER PLATES WELDED TO THE FOOTING PLATES AND,SPOT WELDING TIIE DECKING TO TI1E
GRIDERS.ALL WELDS SHALL USE E70XX ELECTRODES. MINIMUM REBAR CLEARANCE SI[ALL
BE 2'/"CLEAR(CLR)FROM FOOTING EDGES.
RECEIVED STRUCTURAL S"PEEL
t STRUCTURAL SHAPES,MISC.CONNECTION PLATES,ANGLES SHALL CONFORM TO ASTM A588
h WEATI ING STEEL,Fv=50 KSL STEEL IS TO BE ERECTED IN ACCORDANCE WITH A1SC"CODE OF
JUL 31 L ;!J D STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES,,. BOLTS:ASTM A325 HIGH
STRENGTH BOLTS(H.S.B.). ALL BOLTS AND ANCHORS SHALL BE HOT DIPPED GALVANIZED
2 FINISH.ANCHOR BOLTS TO BE SNUG TIGHT ON FIXED END,FINGER TIGHT ON EXPANSION END
615 W.Alder Stfp '
/ _ STEEL DECK
z STEEL SHAL CONFORM TO ASTM A1011,Fv=45 KSI MINIMUM. DECK UNITS SHALL BE 12"X4%'X 9
-� GAGE BRIDGE PLANT MANUFACTURERED BY CONYTECH CONSTRUCTION PRODUCTS INC.
aZ
�a WOOD
SAWN LUMBER: DRIVE LANE PLANTS-NO.2 AND BETTER DOULAS FIR-LARC I I-TREATED
320 /
' 2 me
(3 O
----------------------------- -0 _.-N
).93
JS._
325 I h Z
119
Project Location @ 603
(3)26.38,(300)3.35
approximate milepost
71
2.1 WSDOT SR302 I
300 25 � ,o
330 (300)0.00 20
(3)24.91,1
(106)20.09
(101)331.7
(119)0.00 (3)23.26 i- Site Vicinity Map, Site
(302)0.00
,
15 Location, and General
335 20 Structural Notes
5 10 5,/
337.00, 106
6)0.00
,
15
340 A4 A C flN 3 %