Loading...
HomeMy WebLinkAboutFIR2016-00022 BLA94-77 AF595248 DOR11374-001 Hood and Duct for Spray Booth BLDG #2 - FIR Permit / Conditions - 6/29/2016 coy MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 NTH Phone: (360)427-9670, ext. 352 Mason County 615 W Alder Street Shelton, WA 98584 t854 FIRE PROTECTION PERMIT FIR2016-00022 APPLICANT: SIMS VIBRATION RECEIVED: 6/20/2016 CONTRACTOR: LICENSE: EXP: ISSUED.- 6/29/2016 SITE ADDRESS: 121 W DEVELOPMENT RD BLD#2 SHELTON EXPIRES: 12/29/2016 PARCEL NUMBER: 420020062000 LEGAL DESCRIPTION: S1/2 W OF HY EX 10/147 S 10/144 8/117 PCL 2 OF BLA#94-77 AF#595248 DOR# 11374-001 PROJECT DESCRIPTION: HOOD AND DUCT FOR SPRAY BOOTH GENERAL INFORMATION System Information Type of Use: COMM Fire District: Sprinkler Heads: Audible Switches: Pull Stations: Hood&Duct t: Y Flow Switches: Visual Devices: Door Releases: Pressure Switches:: Smoke Detectors: Duct Detectors: Dry Chemical?: Y Zones: Heat Detectors: Wet Chemical?: N Sprinkler?: N Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: First Floor: Type Amount Due Amount Paid Monitoring Phone No.:() - Second Floor: Hood and Duct Plan Check $126.91 $126.91 Auto Fire Alarm?: Third Floor;: Hood & Duct Permit Fee $195.25 $195.25 Total: $322.16 $322.16 FIR2016-00022 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES FIR2016-00022 CONDITIONS FOR FIR2016-00022 1.) Paint boo h may only be used for non-combustible/non-flammable paint application. Water based paint is approved. X In sal pe anufactures recommendations. XtDuc d ventilation to be installed per manufactures recommendations. X Extern I v ting shall be projected 6' above the roof. ' X Install'nt locks and electrical per manufactures recommendations. X All-electr" al must be at least 3' away from the spray booth or Class 1 Div. 2. X Paint t ge per IFC. X In tions Required: Hood/Duct Inspection (to verify that it is installed per manufacture specs) Interlock Test Alarm Test Fire Sup ssion Test Final / X FIR2016-00022 Please refer to the following pages for conditions of this permit. Page 2 of 5 OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT PLICATION OF JP0,DAYS WILL INVALIDATE THE APPLICATION. IA� a =L/� 6 -;N Sign t re Date J ��SSc' a�I OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) FIR2016-00022 Please refer to the following pages for conditions of this permit. Page 3 of 5 >�x CO MASON COUNTY FIR20 16 JQUb as DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. 8, 615 West Alder Street, Shelton, WA 98584 1854 www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269 Mason County Fire Protection System Permit Application/Underground System Incomplete applications will not be accented Owner: s nn - V/' r 4 Z��6fZ Phone#: y?.7- /-Off/S �iTib� , MailingAddress: 50 lJ. o �.l.�u city: n State: � Zip: tY Site Address: /�/ VU e�/��GD/►���� /)UCity: he �S Gn State: ��- Zip: Parcel#: Legal Description: V Lien/Title Holder: Address: ,�?d14 M4,P 51, 1 f /pU/ City: I/V)q State: Zip: Contractor: Jl��+g Phone #: Address: City: State: Zip: Contractor Registration#: Expiration Date: ript- ic Building Sqre Footage (existing&p oposed : 1 st / 2" / 3rd / Building Use: _&j'21'?\'h ccupancy Classification: Construction Type: 0,7 Type of System: Type of Work: Sprinkler: New System: Wet Dry Modification: Standpipe: Wet Dry Fire Underground R E C I' VED Automatic Fire Alarm: Fire Pump SUN Z 0 06 Hood&Duct: Extraction 615 W. Alde Street Dry Chem: Wet Chem: UL certified Monitoring company: - Phone #: Contractors Bid Price: $ /� Y3 /., dc) (Must be bid in writing) Yl d boe, l.e - 2-q- I (p I_M0M W� f, — jense. C:\Users\TrishW\Desktop\Fire Marshal\Fire Protection System Permit Application.doc iL Plan Submittal Requirements Your plan submittal shall include the following_ 1. Plans shall be on standard 24"x 36"paper, drawn to scale with dimensions and north arrow. 2. Site and Floor plan with cross sectional and exterior elevations. 3. Location of occupancy and/or area separation walls,partitions, stairway enclosures, concealed spaces, etc. 4. Cut sheets and/or references for all new devices. 5. Location/description of all new and existing devices. 6. Battery calculations. 7. Wiring diagrams per floor or zone overlaid on an accurate floor plan. 8. Electrical riser diagram showing all zones, circuits, devices, and end-of-line resistors. 9. Hydraulic calculations. 10. Copy of Contractors bid. 11. Underground Systems; a) NICET FPE Certification b) Underground Civil drawings c) Bedding detail d) Truss blocking/Mega Lugs detail e) Depth/Material for burial f) Pipe size and Type For marijuana extraction see Extraction Permit Information attached. Extraction information must to be provided with permit application. Including a Mechanical Engineered design in accordance with WAC 314-55-104. Identify where the work will take place and identify equipment that will be installed. If cooking will be done as part of the business identify location and provide cooking information. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of S168.50. A plan review fee will be calculated at 65%of the permit fee(minimum $109.50) and is due upon submittal of permit application. Owner's Affidavit I certify that I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the ason unty Fire Marshal. By: Date: 6' 26 1 C:\Users\TrishWOesktop\Fire Marshal\Fire Protection System Permit Application.doc s VWX MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT FIRE MARSHAL Mason County Bldg. III, 426 West Cedar Street, Shelton, WA 98584 www.co.mason.waus Shelton(360)427-9670 Belfair(360)275-4467 Elma (360)482-5269 June 27,2016 Fire Marshal Notes: FILE Permit:FlIR2016-00022 COPY Name: Sims Vibration Lab C/o Jessie Phone:360-427-6031 Fire Marshal Review • Paint booth may only be used for non-combustible/non-flammable paint application. Water based paint is approved. • Install per manufactures recommendations. • Ducting to and ventilation to be installed per manufactures recommendations. • External venting shall be projected 6' above the roof. • Install interlocks and electrical per manufactures recommendations. • All-electrical must be at least 3' away from the spray booth or Class 1 Div.2. • Paint storage per IFC. Inspections Required: • Hood/Duct Inspection(to verify that it is installed per manufacture specs) • Interlock Test • Alarm Test • Fire Suppression Test • Final Plan approval does not relieve the designer/contractor from complying with all applicable codes and requirements as adopted by Mason County and the State of Washington, not does it abrogate the requirements of the requirements of other authorities having jurisdiction. fjgf- Reviewg,d 0 Ai. MUST MEET ALL CURRENT THESE PL4NS MUST BE WASHINGTON STATE CODES ON THE JOB SITE FOR INSPECTION, Page 1 of 2 Jeromy Hicks - RE: OFB-10 Spray booth ,W U From: Bill Brame <billyb@standardtool.com> To: Jeromy Hicks <JHicks@co.mason.wa.us> Date: 6/27/2016 1:14 PM Subject: RE: OFB-10 Spray booth Yes, this looks acceptable. Bill Brame Engineering Tech Local: 336.697.7177 Ext. 128 Email: billyb@standardtool.com Address: 4810 Clover Road I Greensboro, NC 1 27405 Delivering Excellence to the Automotive and Painting Industries. Every Product. Every Customer. Every Day. From: Jeromy Hicks [mailto:JHicks@co.mason.wa.us] Sent: Monday, June 27, 2016 4:06 PM To: Bill Brame Subject: RE: OFB-10 Spray booth Thank you for your help. If we make the owner post "Do Not Use Flammable/Combustible Paint"would you as the manufacture have any issues with the paint booth being placed within 18" of the back wall, 34" to one side, 77" to the other and 70" to the opening in the front. I recognize that the code commentary states that this is for Firefigher Access, but given the use of non-flammable/ non-combustible paints I do not see any hazards as long as there are not any specific manufacture requirement for this booth. Thank you for your help. Jeromy >>> Bill Brame <billyb@standardtool.com> 6/27/201612:34 PM >>> I believe you would need the same setbacks regardless of what type material you are spraying. The operator could spray any type of paint regardless of what is stated. Bill Brame Engineering Tech Local: 336.697.7177 Ext. 128 Email: billyb@standardtooLcom Address: 4810 Clover Road I Greensboro, NC 1 27405 file:///C:/Users/j hicks/AppData/Local/Temp/XPgrpwise/5 77126AFMasonmai1100178786E... 6/2 7/2016 Page 2 of 2 Delivering Excellence to the Automotive and Painting Industries. Every Product. Every Customer. Every Day. From: Jeromy Hicks f mailto:JHicks@co.mason.wa.us] Sent: Monday, June 27, 2016 2:12 PM To: Bill Brame Subject: Re: OFB-10 Spray booth Do you require the same setbacks if the booth is using non-flammable/non-combustible paint? Waterbased? Just want to make sure there are no special requirements from the manufacture. I would assume is the paint is non combustible/ non flammable then these requirements would not apply. Jeromy >>> Bill Brame <billyb@standardtool.com> 6/27/2016 9:39 AM >>> I have attached the drawings and manual for our OFB-10 spray booth. The booth should have 36" clearance on all side per NFPA 33. Bill Brame Engineering Tech Local: 336.697.7177 Ext. 128 Email: billyb@standardtool.com Address: 4810 Clover Road I Greensboro, NC 1 27405 TA! AD Delivering Excellence to the Automotive and Painting Industries. Every Product. Every Customer. Every Day. file:///C:/Users/jhicks/AppData/Local/Temp/XPgrpwise/5 77126AFMasonmai1100178 786E... 6/27/2016 FILE FIRE COPY MARa AL T4nbAk b i Tools and Equipment CO. Duct Work RECEIVED JUN 21 20!5 INSTALLATION MANUAL 35 W.Alder strut a � NIL DATE DATE INSTALLED: t F MPS 6` �N �a oRs O T Y P STANDARD TO01 S AND EQUIPMENT CO. - QP$ - , S0S CtOR t6E NSRP $H� pROM ERICA �CS10NH�SPP9RDwL Sg10Q F��S XpEN-'` E R1GH�tC R,QU ��Rp,G ANy pERs s P E 1p•Ws Q�Klm-G DOES NO WX Cyr'COV vt0V� THESE PLANS MUST BE ON THE JOB SITE MUST MEET ALL CURRENT 7/9�13 FOR INSPECTION. %1"ASHINGTON STATE CODES l Step 1:Assemble 4 ft.sections of ductwork. Make sure duct ends connect together as shown in Example A. Strike with hammer down the seam using a pipe, dolly,or hard surface to ensure proper connection. i I �a�a II �aee Sp EXAMPLE A Cut a 19"x1S" square hole in duct for access door so that the door overlaps duct 1" .Tek screw door against duct and caulk seam. FIG. 1 i I 7f9J13 i . � . i � I Step eFa Aa inside ofanlae ring and Tkscrew while making sure that the duct does not stick below ring and rolled end ofduct faces up. [ may be helpful topreddlholes into duct Nm for esecure hold. t . ` � FIG. 2 Step 3 Bolt downtheductasemblyontothefanbod with the37 hardware provided. FIG. : i i Step 4:Attach 2"d piece of duct to the assembly.The non-rolled end of duct overlaps rolled end of first piece of duct and sits on knuckle.Tek screw every 4"-6"where duct joins to secure into place. i - I TEK SCREW i I { i FIG.4 Step 5: Assembling the curb OPTION A When cutting into the roof,cut a 3" larger diameter hole than the ductwork given.For example, if you have a 24" diameter duct kit, cut the hole 27" inches in diameter. *Code Requirement is that duct is 6 ft. higher than roof line.* j i i i I i i i i i 7/9/13 i � I � � z �Aƒ E± vw »\' i EIG.5 Once the duct protrudes through the roof,sit curbing over the duct,Attach the 4 triangles provided to the curb and the duct 3 shown in FIGURE %secure them with tek screws,Te[screw curb flanges to ma and seal flange with outdoor caulking or roofing tar, �97° - � TEK SCREW AND SEAL — �� - .� - . - �� - �� i FIG. a FIG J ! I � i i � � 7A/13 i i � I i I E OPTION B Cut a 26"x26"square hole into roof. Push curb through roof and tek screw flanges to hold in place, SCREW FLANGES TO ROOF FIG.8 I Seal along seam of curb using outdoor caulking or roofing tar.Attach the 4 triangles provided to the curb ! and the duct as shown in FIGURE 9,secure them with tek screws.*Code Requirement is that duct is 6 ft.higher than roof line before duct end cap is attached(FIGURE 5).* i i , i i SEAL ALONG SEAM FIG.9 7/9/13 i i Step 7; The rain collar is made of 2 pieces(FIGURE 10). Fasten the 2 pieces together by tek screwing the channel as shown in EXAMPLE B. I i I f'77 i I FIG. 10 2)TEK SCREW i 1) PUSH INTO CHANNEL EXAMPLE B I i Step 8;Slide the rain collar over top of duct and rest over top of roof curb, Fasten the rain collar to the curb by tek screwing to the triangles installed to curb and caulking the seam that surrounds duct with outdoor caulking. 7/9/13 I CAULK TEIC SCREW TO TRIANGLES i i I EXAMPLE C i I Step 9: Attach end cap to duct assembly.The end cap overlaps rolled end of duct and sits on knuckle. Tek screw where duct joins to secure into place. I T� A FIG. 11 ' 7/9/13 Page 1 of 1 I have attached the drawings and manual for our OFB-10 spray booth. The booth should have 36" clearance on all side per NFPA 33. Bill Brame Engineering Tech Local: 336.697.7177 Ext. 128 Email: billyb@standardtooLcom Address: 4810 Clover Road I Greensboro, NC 1 27405 yN � kb 11 Delivering Excellence to the Automotive and Painting Industries. Every Product. Every Customer. Every Day. file:///C:/U sers/j hicks/AppData/Local/Temp/XPgrpwise/5 770F49AMasonmai1100178 786E... 6/27/2016 Fan control box 12.0 --- 18.5 1 55.0 JUN 2 0 2016 615 W Alder Street 77.0 .... - _. 0 34.0 Paint Booth 108.0 267.0 ---- 122.5 i 388.0 70.0 Open Face 232.0 E Proposed Light Fixtures 18.0 67.0 144.0 ' Garage Door 54.0 Breaker Panel _. --- 233.5 — - - W.._._._........_..,.... . ......._........__........_......____ _ _. __.. ..__..__...... ......_..........._._....._._.._..___..._...... _............. __................. DIMENSIONS ARE IN INCHES NAME DATE TOLERANCES: DRAWN FRACTION AL• ANGULAR:MACH! BEND! :CHECKED TWO PUCE DECIMAL ! ENG APPR W... - ...._..._......._ __..........— _ __...__.._...._._..._......_._....._....__...._... .. _____.__............ __........................ THREE PLACE DECIMAL ! _._ MFG APPR. I MATERIAL Q.A. COMMENTS: FINISH ................ .. ....... ... NEXT ASSY USED ON SIZE DWG.NO. Drawing . �.... _ .......... .... REv. A 1 APPLICATION DO NOT SCALE DRAWING SCALEI400 'WEIGHT: sHEETIOFi ` s - - - Standard Tools and Equipment Co . TAn DA R D' 4810 CLOVER RD. * GREENSBORO, NC 27405 Tools and Fc#iirmrntCo� Salesman: Jennifer Patterson Ext 138 lenniferp@standardtool.com —` Phone: 1-800-451-2425 * Fax: 1-336-697-1738 Bill to: Ship to: SIMS VIBRATION LABORATORY SIMS VIBRATION LABORATORY DAVE SMITH DAVE SMITH 121 W. DEVELOPMENT ROAD 121 W. DEVELOPMENT ROAD SHELTON, WA 98584 SHELTON, WA 98584 PH: 360-427-6031 FX: 360-427-4025 RECEIVED DAVES@LIMBSAVER.COM JuN 2 0 20116 DATE: 2/29/2016 QUOTE #: P0315273 615 W. t;;u:: .,.. PART # QTY DESCRIPTION PRICE SMM PTB OFB-10 1 OPEN FACE INDUSTRIAL BOOTH 10WX7HX6.5D $2,999.00 SMM PTB 4207-IPBC 1 SHIPPING CRATE 40W X 55H X 124L $200 .00 SMM PTB 7F831 1 24" FAN 2HP THREE PHASE MOTOR 7983 CFM $0.00 EPM CTL ETL-0011 1 ETL FOR EFB, OFB-10 OR SMALLER 2HP, 3PH2O8/2 $999. 00 SMM PTB FS8001 -OFB10 1 MONARCH FIRE SUPPRESSION - OFB10 $2,700.00 SMM PTB PYRO ADMIN 1 ADMINISTRATIVE FEE $0.00 SMM PTB FS80010FB10L 1 LABOR TO INSTALL FIRE SUPPRESSION - OFB10 $1 ,500. 00 SMM PTB DW24PKG 1 24" X 8' DUCT WORK PACKAGE $720.00 SMM PTB ARC-24 1 24" ADJUSTABLE ROOF CURB $0. 00 SMM PMK PIPE-24 3 24" DIA PIPE X 4' $210. 00 Total Items: $9,328.00 Shipping: $1 , 109.00 Tax: $0.00 Total: $10,437.00 I have read and understand the Terms and Conditons Below SIGNATURE DATE PLEASE LOOK OVER THE EQUIPMENT LISTED. DOUBLE CHECK THE PRICING AND SEND IT BACK TO ME WHEN YOU ARE READY TO ORDER. THANKS AGAIN AND PLEASE CALL WITH ANY QUESTIONS! ! ! Jennifer Patterson Standard Tools & Equipment is not responsible for third party inspections should local fire marshals or inspectors require it. Verify with your local permitting authorities to determine if you will need an ETL label on the booth. TERMS AND CONDITIONS Payment Methods We accept Visa, MasterCard, American Express and Discover. Orders may also be prepaid with money order, wire transfer, cash,Paypal, Telecheck, and personal or company check. No order will ship until fund have cleared our bank. Freight/Shipping � - Standard Tools and Equipment Co . TAn VA k V`,,, 4810 CLOVER RD. * GREENSBORO, NC 27405 Tix%and Fqui Salesman: Jennifer Patterson Ext 138 jenniferp(@standardtool.com Phone: 1-800-451-2425 * Fax: 1-336-697-1738 leave our dock. Standard Tools and Equipment uses common carriers, FedEx Ground, UPS, and independent freight haulers for shipping. We negotiate the most competitive freight rates possible and pass these savings along to our customers. We make every effort to minimize freight charges to our customers and provide for timely delivery. -Most items in stock will ship within two business days. -Standard Tools and Equipment will not be liable for any damages related to unavailability of inventory or delays in shipping. -Standard Tools and Equipment ships all products FOB our warehouses. -Title for goods passes to customer when product leaves our dock. Items advertised with "Free Shipping" applies only to shipments within the Continental United States (excludes Alaska, Hawaii, and Canada and Mexico) . Call Sales at 1 -888-312-7488 for a specific freight quote. Delivery and Unloading Customer is responsible for unloading shipment from truck. Standard Tools and Equipment will assume no responsibility for any additional charges or damages that may be incurred as a result of unloading from the delivering carrier's truck. Freight carriers have restrictions on delivering to residential addresses and may require pick-up at freight terminal. Lifts will require a fork-lift to unload. It is advantageous in those cases to ship to a freight terminal where the terminal personnel will unload the product and load it onto the customer's trailer or truck. Lifts cannot be unloaded using a lift gate vehicle. We cannot advise customers of exact time of delivery as we do not ship on our own trucks. We will give our customers an estimated time of delivery and provide them with tracking information. All shipments must be inspected immediately upon receipt. For your protection, any external damage must be noted on the Bill of Lading at the time of delivery in order to qualify for a claim against the freight carrier. Concealed damages must be reported to the freight company within three days of delivery. It is the customer's responsibility to file for damage claims against the freight company. Shortages/missing parts from paint booth orders must be reported to Standard Tools customer service within 30 days of delivery. Warranties All products that appear on our websites or in our catalogs are warranted by Standard Tools and Equipment or the manufacturer against defects in material and workmanship to the extent of the manufacturer's warranty. No other warranties are implied. Contact our sales and customer service department for the warranty on specific models. We provide a parts warranty only. No warranty provided on labor, loss of product use, or loss of business revenue and profits. Warranty Returns Warranty returns for defective products or parts must be authorized in advance and claim must be applied for by the expiration of the warranty period. Customer is - - - ----- Standard Tools and Equipment Co . f J TAnDARD`", 4810 CLOVER RD. * GREENSBORO, NC 27405 Toots arvd FqA Salesman: Jennifer Patterson Ext 138 ienniferpna.standard tool.com --- -- - Phone: 1-800-451-2425 * Fax: 1-336-697-1738 damage during return. Product returned as defective that proves upon inspection not to be defective will be subject to a minimum restocking fee of 20% plus return freight. Credit for warranty returns to third party vendors will be subject to their returns policy. Warranty Replacement Replacement products or parts will be sent out at "No Charge" upon receipt of the defective product from the customer. Alternatively, if the customer wishes to have the warranty replacement shipped prior to the return of the defective product, then the customer must pay for the replacement product at shipping. Credit/refund will be issued to customer upon receipt of defective product. Customer is responsible for loading and unloading warranty replacements. Returns All returns must be authorized prior to shipping. Contact our Customer Service Department for instructions and a return authorization number. Customers may return any unused stock item in the original packaging within 30 days of purchase subject to a 20% restocking fee. All freight charges related to the original shipment and the return will be the responsibility of the customer. Custom manufactured items are not returnable. No credit will be given on unauthorized returns. Shipments refused by customers and returned to Standard Tools and Equipment will be treated as unauthorized returns. Credit will be subject to restocking charges and freight charges related to the return. Terms of Sale Standard Tools and Equipment tries to maintain sufficient inventory on all catalog products to ensure prompt delivery. However, due to high sales volume, some products may be temporarily out of stock. Standard Tools and Equipment will make every effort to process your order in a timely fashion. In no event shall Standard Tools and Equipment be liable for indirect, special, incidental, or consequential damages; including but not limited to, loss of use or loss of business or profits due to temporary unavailability of inventory or delays in shipping. All product prices are subject to change without notice. Standard Tools and Equipment is not responsible for errors in typography or photography. Illustrations are for identification only and actual product may vary due to improvements or changes by the manufacturer or other unforeseen circumstances at the time of printing of this catalog. Pricing, policies and information in this catalog supersede all previous catalogs. Fire Suppression Systems Terms and Conditions of Sale Please do not sign without reading in full The price quoted includes the standard system being installed on site by local licensed installers of TFPP/Pyro-Chem® after the booth is erected. ---- - Standard Tools and Equipment Co . TAM)A R a­_'11� 4810 CLOVER RD. * GREENSBORO, NC 27405 Tcx-is and Equi Salesman: Jennifer Patterson Ext 138 ienniferp(a�standard tool.com —� —' Phone: 1-800-451-2425 * Fax: 1-336-697-1738 The system includes: - Dry Chemical cylinders - Control heads - Nozzles - Fusible links/detectors - Pulleys/tees - Wire rope and alarm bells based on the size booth purchased. The standard installation cost does not include: - Chemical distribution pipe, conduit for electrical and detection, and miscellaneous parts needed to connect pipe or conduit. (These materials vary depending upon thesize and location of the installed booth. ) - All Permitting cost. - Electrical or alarm connections to the system for shut down and alarm purposes. This must be completed by a certified electrician or alarm company. - Customers in remote locations may incur additional installation travel fees. - Final Test Fees for certification when applicable. (The price for the system is based on the exhaust stack going straight up through the roof with a maximum duct run of 22 ft. More costs will be incurred if the booth or stack is modified and if there are any obstructions noted by the installer. ) The miscellaneous costs for the above non-included items are to be negotiated between theowner/end-user and the local licensed installation company prior to any work commencing. These costs are not the responsibility of Standard Tools and Equipment Co. or TFPP/Pyro-Chem®. Local installer contact information can be provided prior to sale or upon request. (The fire suppression standard installation costs will be charged in full concurrent with the shipment of the fire suppression hardware package, on all credit card orders. ) By signing below, I acknowledge that I have read, understood and agree to comply with Standard Tools & Equipment's terms and conditions as stated above. Signature: Date: Quote #: ETL LISTED ELECTRIC CONTROL PANEL FOR PAINT BOOTHS Terms and Conditions of Sale The electrical control panel is certified by Intertek/ETL as compliant with UL-508A and C 22.2 No. 14. Intertek/ETL authorizes Standard Tools to manufacture the panels and then apply the ETL/cETL label after successful testing. The panel is specific for voltage, phase, motor horsepower and number of motors. Because Standard Tools is required to maintain accurate records of labeled products made and shipped, it is critical that the correct information for the electrical service to be used is provided by the Buyer. Responsibility of the Buyer --- --- Standard Tools and Equipment Co . TAMARD 4810 CLOVER RD. * GREENSBORO, NC 27405 Tools and Fquirimcnt Ccz Salesman: Jennifer Patterson Ext 138 jenniferp(a)standardtool.com - Phone: 1-800-451-2425 * Fax: 1-336-697-1738 The buyer is responsible to complete this form and return it to Standard Tools prior to shipment of the control panel. Inaccuracies in providing this info may result in extra charges and delay of product delivery. Conditions of Sale - The ETL label is only valid if the following steps are followed. - The control panel is installed in compliance with the installation instructions by a licensed electrician. - The control panel is located outside the booth interior, at least 36 inches from any booth opening and not damaged by misuse. Terms - The electric control panel can only be returned at no charge for workmanship reasons and only if uninstalled and/or not modified. - The panel should be returned in the original packaging including the outer box DO NOT SHIP THIS PANEL IN JUST THE 12X12X6 BOX. - Returns for inaccurate information provided by the Buyer will be subject to a 20% restocking fee and all shipping costs. - Charges will be incurred for panels that have been installed or modified. - The Buyer will be charged for refusal of the return by STD Tools due to excessive damage. Please fill in the required electrical power, signature and quote #. (Contact your power company if you do not know what phase and voltage you have available in your building) Voltage? (Choose between 208 / 230 / 460) Phase? (Choose 1 phase or 3 phase) Signature Quote # TA IM DA R D ___ Tools and Equipment Co. Our new ETL-listed paint booth control panels have been redesigned with you, the consumer, in mind. The panel is certified by Intertek/ETL as compliant with UL-508A and C O1AnDARD 22.2 No. 14. Intertek/ETL authorizes Standard w. • Tools to manufacture these panels and then apply the ETL/cETL label after successful testing. The I panel is specific for voltage, phase, motor F� u9� horsepower and number of motors. The p Y offer single point electrical connections for the incoming power and outgoing motor leads as well as terminals for an optional airline solenoid. We o, provide two safety interlock terminals for additional r1=�Nf safety device connections. ! On the front cover you will find a QR scan that will take you to a library of electrical drawings, videos and electrical FAQ's that will cover many aspects of installation and operation. With the new LED-lit push on, push off buttons, it's easy to see at a glance if the booth fan and lights are on. We've upgraded our timer to a fixed time that complies with the latest version of NFPA 33. This ensures the booth is properly ventilated when spraying is complete. Our Standard Tools control panels are designed for our non-heated booths and can operate fans up to 5 HP. These are designed for easy installation by your local licensed electrician. re,.famm,t x 1 1 u+ss vtn r Free wrgna ncvt,n!�e wertn niw>, w own exwxr• pFt^J:MECf.At. GIAkl. +6W11YtiW fe? .t3IYT p ' y ?. .war Car.oC FbFRID RwFai[: V TAnDARD Exhaust Ducting Approval Tools and Equipment Co. In order to make sure you get the right exhaust duct package, we will need to know the roof pitch on the building where the booth will be installed. Roof pitch is determined by the number of inches it rises vertically for every 12 inches it extends horizontally. (Also referred to as roof slope or roof slant.) The illustration below shows the measurements being taken from on top of the roof. Simply mark a level at 12", hold it perfectly level and measure from the roof surface to your 12" mark, this will give you the rise. So what does this 3:12 in the example below mean? The 3 means that the roof rises 3" for every 12" it runs. Choices are... • Flat Roof • 1:12 Pitch • 2:12 Pitch • 3:12 Pitch '~ • 4:12 Pitch (Special order) • 5:12 Pitch (Special order) • Others as required My roof pitch is (Example - 3:12 pitch) Quote # Signature TOLERANCE +/- 1/2" 12" CURB 15" X 15" 18" CURB 21" X 21" 24" CURB 27" X 27" 30" CURB 33" X 33" 34" CURB 37" X 37" 42" CURB 45" X 45" B A STANDARD TOOLS AND Greensboro, NC 27405 Ph - 1 -Rnn-451 -747 1; MANUFACTURED IN COMPLIANCE WITH NFPA 33,OSHA, NEC, AND BOCA GUIDELINES Exhaust Fan, 24"dia 2 hp, 7800 CFM @ 0.5"SP UL APPROVED NOTE; CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND REPORT ANY DISCREPANCIES TO ENGINEER PRIOR TO STARTING WORK 24x48 LIGHT FIXTURE, ENCLOSED, UL LISTED, MOUNTED BEHIND 0.25"TEMPERED GLASS WINDOW, 2 FIXTURES OPEN FACE BOOTH OFB-1000-10 10'-3"W x 7'-1-Y2"H x 9'-0"L OUTSIDE 10'-O"W x 7'-0"H x 6'-5"L INSIDETAnDARD NOTES: Greensboro, NC 27405 ALL MATERIALS OF CONSTRUCTION ARE NON-COMBUSTIBLE. Ph - 1-800-451-2425 ALL PANELS ARE 18 GA.GALV SHEET STEEL. WINDOWS ARE Y4"TEMPERED GLASS. title OFB-1000-10 SH 1 OF 2 LIGHT FIXTURES ARE ENCLOSED 2x4 FLORESCENT LAYIN TYPE, UL APPROVED, MOUNTED BEHIND OFB-1000-10 GLASS WINDOW. art no order no FAN IS TUBEAXIAL,ALUMINUM BLADE WITH DRIVE BELT IN ENCLOSED SHROUD, UL APPROVED. _ drawn by MBOWLES date 9-28-04 file name XXXX J,ey C Data/ MONARCH., Chemical Paint Specification Spray AutomotiveBooth Fire 0 0 Sheet Suppression TM ► 1. Fixed temperature mechanical or thermal detectors , 2. Electrical conduit protecting r� stainless steel cable 1 3. Model MCH Control Head a 4. Pneumatic rigid pipe and/or flexible tubing a 5. Model PCI-Series Agent Storage Cylinders a 6 6. Fixed agent distribution piping s 7. Extinguishing Agent Discharge Nozzles 9 8. Alarm Bell 6 10 9. Time Delay 003328PC 10. Model RPS-M Remote Mechanical Pull Station General System Operation Paint spray booths/rooms are areas designed to confine or limit Paint spray booth fire protection is a special application of the escape of spray,vapor,and residue.A power ventilation sys- Pyro-Chem's Monarch® Industrial Fire Suppression System. It tem dedicated to these areas ensures the appropriate exhaust provides a highly reliable response with the versatility of auto- of residual material. Pyro-Chem's dry chemical extinguishing matic or manual activation. agents are appropriate for Class A, B, or C fires.A careful haz- ard survey should be conducted to properly define the type of A modular concept of protection is used. A nozzle, with a pre- fire to be extinguished. In addition to flammable/combustible liq- ►scribed area of protection positioned according to pre-engi- uids, the material composition of the object to be painted must neered placement parameters, protects a modular area of haz- be considered as well as resident material in the protected area. ard.Sets of nozzles supplied by a dedicated cylinder containing ► Total flooding fire extinguishing techniques as defined by NFPA dry chemical extinguishing agent and piped in an approved pat- 17 are utilized by Pyro-Chem's Monarch@ fire suppression sys- tern consistent with the application coverage are utilized. tems to protect the entire hazard which includes the work area, ►Mechanical or electrical fixed temperature detectors are posi- exhaust plenum area, pits, under floor's and exhaust ducts. tioned strategically within the protected area to monitor ambient temperature and initiate an output should the rated temperature The National Fire Protection Association Standard No. 33 be exceeded.The detector input is"sensed"at the control head. "Spray Application Using Flammable and Combustible The control head responds by discharging the system by pneu- Materials" and No. 17 "Dry Chemical Extinguishing Systems" matically depressing the stored agent cylinder valve. The sys- are primary reference sources and provide guidelines for the tem is provided with a time delay device to allow for fan shut proper application and design of Pyro-Chem's Monarch® down before agent discharge.A manual means of activating the Industrial Fire Suppression Systems in the specialized protec- system is also provided. tion of paint spray booths and rooms. Underwriters Laboratories testing provides pre-engineered system application parameters Expanded capability is available to provide remote manual acti- allowing the flexibility to protect a variety of paint spray vation, auxiliary electrical outputs and/or audible alarms. This booth/room layouts to Underwriter's Standard UL 1254,effective optional equipment will enhance the basic system functions and September 1998,with confidence. be applicable when designing custom configurations to suit a particular customer's needs and/or comply with local codes. MM Pyro•Tj CAOne Stanton Street May 10, 2004 Marinette, W1 54143 PC98231(2) Suggested Architect's Specifications head, exercising the control head(for electrical detectors). ►3.4-Pneumatic actuation.For systems requiring more than five 1. General agent cylinders,the system shall have a PAC-Series Pneumatic 1.1 -The fire extinguishing system shall be the stored pressure Actuating Cylinder whose valve opens upon activation of the dry chemical pre-engineered fixed nozzle type manufactured by control head. The valve shall release nitrogen from the PAC ► Pyro-Chem. The system shall provide for the protection of the cylinder into the pneumatic pipe and tubing network.This nitro- paint spray area(s) described in drawing . (Note gen shall depress a piston above the valve stem in each agent drawing number and revision.) cylinder, opening each agent cylinder valve and releasing the 1.2 - The system shall be capable of automatic and manual pressurized agent. actuation. It shall be U.L. Listed and installed in conformance 3.5-Manual actuation.The system shall have mechanical man- with National Fire Protection Association Standard No. 17, "Dry ual actuation capability requiring no electrical power. This is Chemical Extinguishing Systems" and No. 33, "Spray accomplished locally by twisting the handle on the cover of the Application using Flammable and Combustible Materials," and MCH or ECH Control Head, or remotely by means of a Model comply with all local and/or state Codes and Standards. RPS-M remote mechanical pull station. 1.3 - The system shall be designed for operation at ambient ►3.6-Auxiliary output.The system shall provide for the shut off ► temperatures from 32°F to 120°F(0 °C to 49°C). ►of power to equipment within the hazard and to ventilation sys- 2. Cylinder and Agent ►tems in the event of system actuation.This is accomplished by 2.1 -Agent.The system shall use Pyro-Chem monoammonium means of dry contacts on a Model MS-SPDT or MS-DPDT phosphate-based dry chemical agent. miniature switch installed in the control head. The miniature 2.2 - Cylinders. Steel cylinders manufactured, tested, and switch may also be used for auxiliary functions such as audible marked in accordance with DOT 4B 350 or DOT 413 500 shall be alarms or alarm signaling. used to store the extinguishing agent. Cylinder Models 3.7-Supervision.A Model SM Series Solenoid Monitor shall be PCI-15ABC shall be used with extinguishing agent fill weight of used to supervise the integrity of all electrical actuation circuits, 12.5 lbs. Cylinder Models PCI-17ABC shall be used with extin- whether automatic or manual. guishing agent fill weight of 17 lbs. Cylinder Models 3.8 - Manual electrical actuation (optional). The system shall PCI-25sABC shall be used with extinguishing agent fill weight of have electrical manual actuation capability. This is accom- 25 lbs. Cylinder Models PCI-35ABC shall be used with extin- plished by the use of a Model RPS-E2 Remote Electrical Pull guishing agent fill weight of 35 lbs.Cylinder Models PCI-70ABC Station installed in the automatic detection circuit. shall be used with extinguishing agent fill weight of 70 lbs. All 4. Distribution Nozzles models are charged with dry nitrogen to 350 psig at 70oF. 4.1 - Nozzles. The system shall utilize Pyro-Chem discharge 2.3-Cylinder valve.A pressure sealed poppet-type valve hav- nozzles to distribute agent throughout the hazard area. The ing a brass body, stainless steel stem with rubber seat washer, model, quantity, location, and orientation of nozzles shall be in fusible safety relief assembly, and pressure gage shall be used accordance with Pyro-Chem Industrial Fire Suppression System on all agent cylinders. ►Technical Manual, Part No. 551229. 2.4-Cylinder bracketing. Cylinders shall be mounted vertically. 4.2 - Nozzle covers. All nozzles shall be installed with nozzle The cylinders shall be secured by use of a steel mounting brack- covers to prevent foreign matter from clogging the discharge et affixed to a rigid object capable of supporting the weight of the nozzles. filled cylinder and the concussion of cylinder discharge. 5. Pipe and Fittings 3. Actuation Controls 5.1 - Pipe. All pipe shall be Schedule 40 black, galvanized, 3.1 - Control Head. The system control head shall include a chrome plated or stainless steel pipe in compliance with NFPA Model MCH, NMCH or ECH-Series Control Head. The control 17.All pipe ends shall be thoroughly reamed after cutting, and ► head shall be mounted directly on the time delay in a Model all oil, chips, and debris shall be removed prior to nozzle instal- 1 MB-P2 control-head mounting bracket. The control head can lation. ► actuate up to five centrally located agent cylinders. A carbon 5.2 - Fittings. Standard weight malleable, galvanized, chrome dioxide pilot cartridge that complies with MIL-CO601 G shall be plated or stainless steel fittings shall be used. used as an integral component of the control head.Control head 5.3 - Size. All system pipe and fittings will be sized in accor- status shall be visually indicated by a SET/FIRED indicator. dance with the system Technical Manual. No substitutions are 3.2 - Time Delay. The system shall have a Model T-10 Time allowed. Delay to allow for fan shut down before agent discharge. 5.4-Joints. No joint sealant shall be used in the discharge pip- 3.3 - Detection. The ambient temperature of the hazard area ing. Exception:Teflon tape may be used to ensure a snug fit. shall be monitored by fixed temperature mechanical or electrical 5.5 - Straps. All system discharge pipe shall be securely fas- thermal detectors. When the temperature of the hazard area tened by means of pipe hangers and/or pipe straps. UL Listed exceeds the rating of any detector, the detector shall a)release pipe hangers shall be used. tension in a cable connected to the control head, causing con- 5.6 - Union. A union shall be installed in the discharge piping trol head activation(for mechanical detectors),or b)close a nor- conveniently close to the cylinder valve to permit disconnection mally open switch element within the detector, sending a signal for inspection and service. to the control head which energizes a solenoid in the control MOUNTING BRACKET MODEL NO. A B C D WEIGHT USED p PCI-15ABC 6.00 21.44 27.19 18.69 30lbs. MB-15 e PCI-17ABC 8.00 24.81 30.56 22.06 50lbs. MB-15 PCI-25sABC 8.00 24.81 30.56 22.06 58lbs. MB-15 PCI-35ABC 10.00 29.94 35.69 27.18 71 lbs. MB-1 PCI-70ABC 12.00 35.31 41.06 32.56 130lbs. MB-1 ALL DIMENSIONS IN INCHES Aqualac O ME COATINGS Safety Data Sheet according to Federal Register I Vol 77,No.58 I Monday,March 26,2012/Rules and Regulations "SECTION 1.1. Identification Product form Mixture Product name Aqualac Product code 35 SERIES AQUALAC 1.2. Relevant identified uses of the substance or mixture and uses advised against RECEIVED No additional information available 1.3. Details of the supplier of the safety data sheet JUN 2 0 2016 Prime Coatings 1002 Hickory Street 615 W. Alder Street Pewaukee,WI 53072 T 262-691-1930 www r)rimecoatings.net 1.4. Emergency telephone number No additional information available SECTION 2.1. Classification of the substance or mixture GHS-US classification Not classified 2.2. Label elements GHS-US labeling No labeling applicable 2.3. Other hazards No additional information available 2.4. Unknown acute toxicity(GHS US) Not applicable SECTION . . 3.1. Substance Not applicable 3.2. Mixture Name Product Identifier % GHS-US classification Titanium Dioxide (CAS No)13463-67-7 0-20 Carc.2,H351 Ethylene glycol monobutyl ether (CAS No)111-76-2 1-5 Flam.Liq.4,H227 Acute Tox 4(Oral),H302 Acute Tox 4(Dermal),H312 Acute Tox 4(inhalation:dust,mist), H332 Skin Irrit.2,H315 Silicone Dioxide (CAS No)14808-60-7 1-5 Carc.1A,H350 NMP (CAS No)872-50-4 1-5 Flam.Liq.4,H227 Skin Irrit.2,H315 STOT SE 3,H335 Carbon Black pigment (CAS No)1333-86-4 0-1 Carc.2,H351 Full text of H-phrases:see section 16 :SECTION 4.1. Description of first aid measures First-aid measures general Never give anything by mouth to an unconscious person. If you feel unwell,seek medical advice(show the label where possible). First-aid measures after inhalation Allow victim to breathe fresh air.Allow the victim to rest. First-aid measures after skin contact Remove affected clothing and wash all exposed skin area with mild soap and water,followed by warm water rinse. 1 1/0612 0 1 5 EN(English US) Page 1 • r Aqualac Safety Data Sheet according to Federal Register!Vol 77,No 581 Monday,March 26,2012/Rules and Regulations First-aid measures after eye contact Rinse immediately with plenty of water.Obtain medical attention if pain,blinking or redness persist. First-aid measures after ingestion Rinse mouth.Do NOT induce vomiting.Obtain emergency medical attention. 4.2. Most important symptoms and effects, both acute and delayed Symptoms/injuries : Not expected to present a significant hazard under anticipated conditions of normal use. 4.3. Indication of any immediate medical attention and special treatment needed No additional information available SECTION 5.1. Extinguishing media Suitable extinguishing media Foam. Dry powder.Carbon dioxide.Water spray.Sand. Unsuitable extinguishing media Do not use a heavy water stream. 5.2. Special hazards arising from the substance or mixture No additional information available 5.3. Advice for firefighters Firefighting instructions Use water spray or fog for cooling exposed containers.Exercise caution when fighting any chemical fire.Prevent fire-fighting water from entering environment. Protection during firefighting Do not enter fire area without proper protective equipment,including respiratory protection. SECTION 6.1. Personal precautions,protective equipment and emergency procedures 6.1.1. For non-emergency personnel Emergency procedures Evacuate unnecessary personnel. 6.1.2. For emergency responders Protective equipment Equip cleanup crew with proper protection. Emergency procedures Ventilate area. 6.2. Environmental precautions Prevent entry to sewers and public waters.Notify authorities if liquid enters sewers or public waters. 6.3. Methods and material for containment and cleaning up Methods for cleaning up Soak up spills with inert solids,such as clay or diatomaceous earth as soon as possible.Collect spillage.Store away from other materials. 6.4. Reference to other sections See Heading 8.Exposure controls and personal protection. SECTION • . and storage 7.1. Precautions for safe handling Precautions for safe handling Wash hands and other exposed areas with mild soap and water before eating,drinking or smoking and when leaving work.Provide good ventilation in process area to prevent formation of vapor. 7.2. Conditions for safe storage,including any Incompatibilities Storage conditions Keep only in the original container in a cool,well ventilated place away from:Keep container closed when not in use. Incompatible products Strong bases.Strong acids. Incompatible materials Sources of ignition.Direct sunlight. SECTION .• controls/personal protection 8.1. Control parameters Titanium Dioxide(1 34 6 3-6 7-7) ACGIH ACGIH TWA(mg/m') 1 mg/m' ACGIH Remark(ACGIH) LRT irr;A3 OSHA OSHA PEL(TWA)(mg/m') 15 mglm' 11/06/2015 EN(English US) 218 Aqualac Safety Data Sheet according to Federal Register/Vol.77,No 58/Monday,March 26.2012/Rules and Regulations Silicone Dioxide(14808-60-7) _ ACGIH ACGIH TWA(mg/m') 0.025 mg/m'(Silica-Crystalline Quartz; USA;Time- weighted average exposure limit 8 h;TLV-Adopted Value;Respirable fraction) OSHA Remark(OSHA) f (3)See Table Z-3. Ethylene glycol monobutyl ether(111-76-2) ACGIH ACGIH TWA(ppm) 20 ppm(2-Butoxyethanol(EGBE);USA;Time- weighted average exposure limit 8 h;TLV-Adopted Value) ACGIH Remark(ACGIH) Eye&URT irr OSHA I OSHA PEL(TWA)(mg/m') 240 mg/m' OSHA OSHA PEL(TWA)(ppm) 50 ppm - -- - --- . Carbon Black pigment(1333-86-4) ACGIH ACGIH TWA(mg/m') 3 mg/m' ACGIH Remark(ACGIH) Bronchitis OSHA OSHA PEL(TWA)(mg/m') 3.5 mg/m' 8.2. Exposure controls Personal protective equipment Avoid all unnecessary exposure. Hand protection Wear protective gloves/protective clothing/eye protection/face protection protective gloves. Eye protection Chemical goggles or safety glasses. Respiratory protection Wear appropriate mask. Other information Do not eat,drink or smoke during use. SECTIONproperties9.1. Information on basic physical and chemical properties Physical state Liquid Color Colorless Odor characteristic Odor threshold No data available pH 7-9 Melting point No data available Freezing point No data available Boiling point No data available Flash point No data available Relative evaporation rate(butyl acetate=l) No data available Flammability(solid,gas) No data available Explosion limits No data available Explosive properties No data available Oxidizing properties No data available Vapor pressure No data available Relative density No data available Relative vapor density at 20'C No data available Specific gravity/density 1.1- 1.3 Solubility Water:Solubility in water of component(s)of the mixture •: 0.0008 g/100ml •:<0.1 g/t 00ml • : 100 g/100ml •: 0.15 g/100ml •: 0.090 g/100m1 100 g/100ml(20'C,soluble) •: 0.04 g/100ml •: insoluble •: 0.15 g/100ml •: Complete •: Complete •: 11.2 g/100ml(20`C) •: insoluble •:<0.1 g/100mt •: Complete •: <0.01 g/100ml Log Pow No data available Auto-ignition temperature No data available Decomposition temperature No data available 11/06/2015 EN(English US) 3/8 Aqualac Safety Data Sheet according to Federal Register/Vol 77,No.58!Monday,March 26,2012/Rules and Regulations Viscosity No data available Viscosity,kinematic Nodata available Viscosity,dynamic No data available 9.2. Other information VOC content <180-240 g/1 ,SECTION1 10.1. Reactivity No additional information available 10.2. Chemical stability Not established. 10.3. Possibility of hazardous reactions Not established. 10.4. Conditions to avoid Direct sunlight.Extremely high or low temperatures. 10.5. Incompatible materials Strong acids.Strong bases. 10.6. Hazardous decomposition products fume.Carbon monoxide.Carbon dioxide. • Toxicological 11.1. Information on toxicological effects Acute toxicity Not classified Titanium Dioxide(13463-67-7) LD50 oral rat >10000 mg/kg(Rat;OECD 425:Acute Oral Toxicity:Up-and-Down Procedure;Experimental value;>5000 mg/kg bodyweight;Rat;Experimental value) LD50 dermal rabbit >10000 mg/kg(Rabbit;Literature study) LC50 inhalation rat(mg/l) >6.8 mgA/4h(Rat;Experimental value) NMP(872-60-4) LD50 oral rat 3914 mg/kg(Rat;Equivalent or similar to OECD 401;Literature study;4150 mg/kg bodyweight;Rat;Experimental value) ATE US(oral) 3914.000 mg/kg body weight Ethylene glycol monobutyl ether(111-76-2) LD50 oral rat 1746 mg/kg body weight(Rat:Equivalent or similar to OECD 401;Experimental value) LD50 dermal rat >2000 mg/kg body weight(Rat;Experimental value;OECD 402:Acute Dermal Toxicity) LC50 inhalation rat(mgA) 2.2 mg/l/4h(Rat;Experimental value) LC50 inhalation rat(ppm) 450 ppm/4h(Rat;Experimental value) ATE US(oral) 1746.000 mg/kg body weight ATE US(dermal) 1100.000 mg/kg body weight ATE US(gases) 450.000 ppmV/4h ATE US(vapors) 2.200 mg/114h ATE US(dust,mist) 2.200 mg/V4h Carbon Black pigment(1333-86-4) LD50 oral rat >8000 mg/kg(Rat;Equivalent or similar to OECD 401:Experimental value) LD50 dermal rabbit >3000 mg/kg(Rabbit) Skin corrosion/irritation Not classified pH:7-9 Serious eye damagelirritation Not classified pH:7-9 Respiratory or skin sensitization Not classified Germ cell mutagenicity Not classified 1110612015 EN(English US) 4/8 r Aqualac Safety Data Sheet according to Federal Register/Vol.77,No.58/Monday,March 26,2012/Rules and Regulations Carcinogenicity Not classified Titanium Dioxide(13463-67-7) IARC group 2B-Possibly carcinogenic to humans Silicone Dioxide(14808-60-7) IARC group 1 -Carcinogenic to humans ( Ethylene glycol monobutyl ether(111-76-2) IARC group 3-Not classifiable Carbon Black pigment(1333-86-4) IARC group 26-Possibly carcinogenic to humans Reproductive toxicity Not classified Specific target organ toxicity(single exposure) Not classified Specific target organ toxicity(repeated Not classified exposure) Aspiration hazard Not classified Potential Adverse human health effects and Based on available data,the classification criteria are not met. symptoms 'SECTIONEcological 12.1. Toxicity Titanium Dioxide(13463-67-7) f EC50 Daphnia 1 >100 mg/l(LC50;Equivalent or similar to OECD 202;48 h;Daphnia magna;Static system; Fresh water;Weight of evidence) Threshold limit algae 1 61 mgA(EC50;Other;72 h;Pseudokirchneriella subcapitata;Static system; Fresh water; j Experimental value) NMP(872-50-4) ----_—- — �LC50 fish 1 3048 mg/I(LC50;96 h;Salmo gairdneri) j EC50 Daphnia 1 4897 mgA(EC50;48 h;Daphnia magna) 1 Threshold limit algae 1 >500 mg/I(EC50) i Threshold limit algae 2 600.5 mg/I(EC50;DIN 38412-9;72 h;Desmodesmus subspicatus;Static system;Fresh L water;Experimental value) Ethylene glycol monobutyl ether(111-76-2) LC50 fish 1 1474 ppm(LC50;OECD 203:Fish,Acute Toxicity Test;96 h;Oncorhynchus mykiss;Static _ system;Fresh water;Experimental value) EC50 Daphnia 1 1550 mgA(EC50;OECD 202:Daphnia sp.Acute Immobilisation Test;48 h;Daphnia magna; Static system;Fresh water;Experimental value) Threshold limit algae 1 911 mg/i(EC50;OECD 201:Alga,Growth Inhibition Test;72 h;Pseudokirchneriella subcapitata;Static system;Fresh water;Experimental value) Threshold limit algae 2 88 mgA(NOEC;OECD 201:Alga,Growth Inhibition Test;72 h;Pseudokirchneriella subcapitata;Static system;Fresh water;Experimental value) Carbon Black pigment(1333-86-4) LC50 fish 1 >1000 mg/I(LC50;OECD 203:Fish,Acute Toxicity Test;96 h;Brachydanio redo) EC50 Daphnia 1 >5600 mgA(EC50;OECD 202:Daphnia sp.Acute Immobilisation Test;24 h;Daphnia magna; _ Static system;Fresh water) LC50 fish 2 1000 mg/1(LCO;OECD 203:Fish,Acute Toxicity Test;96 h;Brachydanio rerio;Semi-static system;Fresh water;Experimental value) Threshold limit algae 1 >10000 mg/I(EC50;OECD 201:Alga,Growth Inhibition Test;72 h;Scenedesmus subspicatus;Static system;Fresh water;Experimental value) 12.2. Persistence and degradability Aqualac Persistence and degradability Not established. Titanium Dioxide(13463-67-7) Persistence and degradability Biodegradability:not applicable.Low potential for mobility in soil. 11/06/2015 EN(English US) 5/8 Aqualac Safety Data Sheet according to Federal Register/Vol.77,No.58/Monday,March 26,20121 Rules and Regulations Titanium Dioxide(13463-67-7) - Biochemical oxygen demand(BOD) Not applicable Chemical oxygen demand(COD) Not applicable ThOD Not applicable NMP(872-50-4) Persistence and degradability Readily biodegradable in water. Inherently biodegradable.Biodegradable in the soil.Highly mobile in soil.Photodegradation in the air. Biochemical oxygen demand(BOD) 1.07 g Oz/g substance Chemical oxygen demand(COD) 1.56 g Wg substance ThOD — ----- 1.9 g OJg substance ------------ - BOD(%of ThOD) 0.56 Silicone Dioxide(14808-60-7) — —______ ----------------- - ---__ _ -------------____- ---___ - ___._ -.._..._.-------- Persistence and degradability Biodegradability:not applicable. Biochemical oxygen demand(BOD) Not applicable Chemical oxygen demand(COD) Not applicable ThOD Not applicable ----------._.._-- — Ethylene glycol monobutyi ether(111-76-2) Persistence and degradability Readily biodegradable in water.Low potential for adsorption in soil.Photooxidation in the air. Carbon Black pigment(1333-86-4)-- Persistence and degradability Biodegradability:not applicable.Biodegradability in soil:not applicable.Adsorbs into the soil. ThOD Not applicable 12.3. Bioaccumulative potential Aqualac Bioaccumulative potential Not established. Titanium Dioxide(13463-67-7) Bioaccumutative potential ( Not bioaccumulative. NMP(872-50-4) ? Log Pow 0.73--0.46(Experimental value;Experimental value;OECD 107:Partition Coefficient(n- -� — octanol/water):Shake Flask Method) j Bioaccumulative potential Not bioaccumulative. Ethylene glycol monobutyl ether(111-76-2) Log Pow 0.81(Test data;20°C) Bioaccumulative potential Low potential for bioaccumulation(Log Kow<4). Carbon Black pigment(1333-86-4) - _--- Bioaccumulative potential Not bioaccumulative. 12.4. Mobility in soil NMP(872-50-4) _ - Surface tension 0.407 N/m Log Koc Koc,20.94;Calculated value;log Koc:1.32;Calculated value Ethylene glycol monobutyi ether(111 76-2) Surface tension ! 0.065 N/m(20-C;Calculated value) — __._.--_—__.___.—___ Carbon Black pigment(1333-86-4) Ecology-soil ( Not toxic to plants.Not toxic to animals. 12.6. Other adverse effects Effect on the global warming No known ecological damage caused by this product. Other information Avoid release to the environment. 1 110 6/2 0 1 5 EN(English US) 6/8 i Aqualac Safety Data Sheet according to Federal Register/Vol.77,No 58/Monday,March 26,2012/Rules and Regulations SECTIONDisposal 13.1. Waste treatment methods Waste disposal recommendations Dispose in a safe manner in accordance with local/national regulations. Ecology-waste materials Avoid release to the environment. • Transport Department of Transportation(DOT) In accordance with DOT Not regulated for transport TDG No additional information available Transport by sea No additional information available Air transport No additional information available :SECTION 15.1.US Federal regulations Titanium Dioxide(13463-67-7) Listed on the United States TSCA(Toxic Substances Control Act)inventory NMP(872-50-4) Listed on the United States TSCA(Toxic Substances Control Act)inventory Subject to reporting requirements of United States SARA Section 313 Silicone Dioxide(14808-60-7) Listed on the United States TSCA(Toxic Substances Control Act)inventory Ethylene glycol monobutyl ether(111-76-2) — Listed on the United States TSCA(Toxic Substances Control Act)inventory Carbon Black pigment(1333-86-4) Listed on the United States TSCA(Toxic Substances Control Act)inventory 15.2.International regulations CANADA No additional information available EU-Regulations No additional information available National regulations r Titanium Dioxide(13463-67-7) Listed on IARC(International Agency for Research on Cancer) Silicone Dioxide(14808-60-7) Listed on IARC(International Agency for Research on Cancer) Carbon Black pigment(1333 86 4) Listed on IARC(International Agency for Research on Cancer) 15.3.US State regulations NMP(872-50-4) U.S.-California- U.S.-California- U.S.-California- U.S.-California- Non-significant risk Proposition 65- Proposition 65- Proposition 65- Proposition 65- level(NSRL) Carcinogens List Developmental Toxicity Reproductive Toxicity- Reproductive Toxicity- Female Male No Yes No No 3200 11/06/2015 EN(English US) 718 Aqualac Safety Data Sheet according to Federal Register/Vol.77.No 58/Monday,March 26,2012/Rules and Regulations Carbon Black pigment(1333-86-4) U.S.-California- U.S.-California- I U.S.-California- U.S.-California- Non-significant risk Proposition 65- Proposition 65- Proposition 65- Proposition 65- level(NSRL) Carcinogens List Developmental Toxicity Reproductive Toxicity- Reproductive Toxicity- Female Male Yes No j No No Titanium Dioxide(13463-67-7) U.S.-New Jersey-Right to Know Hazardous Substance List NMP(872-50-4) U.S. New Jersey Right to Know Hazardous Substance List Silicone Dioxide(14808-60-7) U.S.-New Jersey-Right to Know Hazardous Substance List Ethylene glycol monobutyi ether(111-76-2) _ U.S.-New Jersey-Right to Know Hazardous Substance List U.S.-Pennsylvania-RTK(Right to Know)List Carbon Black pigment(1333-86-4) U.S.-New Jersey-Right to Know Hazardous Substance List SECTIONOther Other information None. Full text of H-phrases: Acute Tox.4(Dermal) Acute toxicity(dermal)Category 4 Acute Tox.4(Inhalation:dust.mist) Acute toxicity(inhalation:dust,mist)Category 4 Acute Tox.4(Oral) Acute toxicity(oral)Category 4 Carc.1A Carcinogenicity Category 1A Carc.2 Carcinogenicity Category 2 Fiam.Liq.4 Flammable liquids Category 4 Skin Irdt.2 Skin corrosion/irritation Category 2 STOT SE 3 Specific target organ toxicity(single exposure)Category 3 H227 Combustible liquid H302 Harmful if swallowed H312 Harmful in contact with skin H315 Causes skin irritation H332 Harmful if inhaled H335 May cause respiratory irritation H350 May cause cancer H351 Suspected of causing cancer SDS US(GHS HazCorn 2012) This information is based on our current knowledge and is intended to describe the product for the purposes of health,safety and environmental requirements only 0 should not therefore be construed as guaranteeing any specific property of the product 1 110 6/2 0 1 5 EN(English US) 818