BLD2009-00336 SFR - BLD Permit / Conditions - 5/21/2009
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(3600127-7262 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton, WA 98584 i� RESIDENTIAL BUILDING PERMIT -00 OWNER: LOREN DEATON BLD2009 336 CONTRACTOR: LICENSE: EXP: RECEIVED: 5/1/2009 SITE ADDRESS: 81 E BLACKHAWK CT BELFAIR ISSUED: 5/21/2009 PARCEL NUMBER: 122187800040 EXPIRES: 11/21/2009 LEGAL DESCRIPTION: 4-48 PTN SE SW S 21/72 S 30/6 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE/garage TRAILS END LAKE RD LEFT ON E RASOR RD W RIGHT ON RICHERDSON RD RIGHT ON BLACK HAWK CT General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R-3U Lot Size: Deck: 22 Type of Work: NEW Fire Dist.: 2 No. of Stories: 2 Occ. Load: Building:2,799 Garage-Attached 624 Valuation: Building Height: 27 Occ. Status: Primary Basement: COVPORCH 63 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: S 125.0 Ft. Shoreline: Ft. Water Body: Rear: N 125.0 Ft. Slope: 500.0 Ft. SEPA?: No Model: Width: Ft. Side 1: E 392.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: W 222.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee TW 5/1/2009 $1,355.74 S12009000 Hosebibs 3 Furnace<100K 1 EH Plan Review TW 5/1/2009 $41.00 S12009000 Lavatories 4 Gas Outlets 3 Water Adequacy Plan Review TW 5/1/2009 $41.00 S12009000 Showers 1 Propane Tank 1 Planning Review Fee TW 5/1/2009 $205.00 S12009000 Kitchen Sink, w/disposal 1 Ventilation Fan 5 Fire Warden Review TW 5/1/2009 $73.00 §i1 bbsbbb Water Closets (Toilets) 3 Heat Pump 1 ADJUST--Plan Check Fee ARC 5/13/2009 $7.28 612009000 Water Heaters 1 Propane Stove 1 Building State Fee ARC 5/13/2009 $4.50 612009000 Bath Tubs 2 Dryer Vent 1 Building Permit Fee ARC 5/13/2009 $2,096.95 B12009000 Clothes Washer 1 Mechanical Permit Fee ARC 5/13/2009 $255.90 612009000 Mechanical Base Fee ARC 5/13/2009 $28.50 612009000 Plumbing Permit Fee ARC 5/13/2009 $128.00 B12009000 Plumbing Base Fee ARC 5/13/2009 $24.70 612009000 EH Plan Review ADR 5/19/2009 $62.00 612009000 Total $4,323.57 BLD2009-00336 Please referto the following pages for conditions of this permit. 1 of 6 CASE NOTES FOR BLD2009-00336 CONDITIONS FOR BLD2009-00336 1) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X %A,/,) 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X y- 3) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X tO 4) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 5) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. 6) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window (Max U-Factor):0.35, Skylight(Max U-Factor):0.58, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab Insulation R-10. Exception: R-30 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the underside of the roof sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation. X 7) Per 2003 IRC -SECTION 1609-WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. X W-4 BLD2009-00336 Please referto the following pages for conditions of this permit. 2 of 6 8) Per IRC - SECTION R905- REQUIREMENTS FOR ROOF COVERINGS- R905.1 Roof covering application. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturer's installation instructions. X 9) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 10) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X WIV-1 11) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X I-ID4 12) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X- �bn 13) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X BLD2009-00336 Please referto the following pages for conditions of this permit. 3 of 6 14) Permanent Address must be posted and visible from the road Deck must be safe and meet code for year building permit was issued. Rebuilt decks are required to meet current code. All guardrails and handrails must be in good condition and meet code for year built or current code if replaced. Skirting must be vented 1:150 and backfill sloped away from unit 2% for a minimum of 5' around the perimeter of the unit Gutters and downspouts must be installed with splash blocks provided All exterior penetrations must be sealed HWT Pressure relief line and dryer vent must exit skirting a minimum of 6"with a maximum of 24" above grade. The unit shall have a minimum of 16"x24" crawl space access provided HOWEVER, if the unit has not received a set up inspection and is skirted, 4 panels centrally located (one on each side of unit) shall be removed by the owner/applicant prior to requesting the inspection. All conditions on the original or issued permit must be met If the unit was installed by a WAINS certified installer/contractor since July 1, 2003, CTED Installer Tags must be available It shall be the responsibility of the person requesting the inspection to provide the manufacturer specifications, ANSI Standards or approved engineered design for the installation of the unit and have them available on site for inspection. Each inspection required will be assessed a fee as adopted under Mason County current fee schedule. Re-Inspection fees will be assessed each time an inspection is requested and required items are not completed prior to the inspection being performed ENFORCEMENT PROVISION: Any manufactured/mobile home and/or appurtenant structures found non-compliant with any county or state regulation are subject to enforcement action and subsequent violation and penalties pursuant to the Mason County Code. X ItiAO 15) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X l 16) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X Wb BLD2009-00336 Please refer to the following pages for conditions of this permit. 4 of 6 17) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X_ i& 18) All property lines shall be clearly identified at the time of foundation inspection. X UhQ 19) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X V y/_� 20) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 21) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 610 22) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X (non 23) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X in 4 24) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-09$2.�The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X J 25) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X VIQ 26) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X BLD2009-00336 Please referto the following pages for conditions of this permit. 5 of 6 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a progress insp tion.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property an r ture for review and inspection. OWN ER OR AGENT: DATE: BLD2009-00336 Please referto the following pages for conditions of this permit. 6 of 6 ti k!. y „j• I ..^.'1. •{IYI AM I �A.y-.,M ,K{' .tl ,11A1: ..., G•^�.��� �. N i „'7A8 �iS4:I w^�AIA�L. �..:��Al..it"JA�I \�.4��}x�� �. 't.'L fi\ ., t '� ��-�� al. 7��1L �•3� � ;� �'Yn+c."�� '�'� �.��' �','fiN .4r `�a�._�V�''x-.' :v •�r� �,:� '�6i .s.�i.•-�/ WYm �i .�f;�u: ':f �: r�� �" tf�{4+�, �f ;yli Grff}+1• � �Y'�T-� '°/'�.i� G '� '`�a✓ � �, a'�;s THIS IS TO CERTIFY THAT THIS HOME CONSTRUCTED BY `�s\CAAsss � �MOffffpN.l gale r _ �lliNTfOui,� insulation r: HAS BEEN INSULATED WITH MATERIALS LISTED HEREIN MEETING STANDARDS OF STATE,FEDERAL AND MANUFACTURERS SPECIFICATIONS. GALE INSULATION GUARANTEES THE INSTALLATION AND WORKMANSHIP OF THESE INSULATION PRODUCTS FOR THREE(3)YEARS.THE THERMAL AND ACOUSTICAL PERFORMANCE OF THE PRODUCTS '- ARE WARRANTEED BY THE MANUFACTURER. P R-value thickness kraft unlaced fail FS-25 loose fill Ceilings ❑ O ❑ ❑ f r � � Floors ❑ ❑ ❑ ❑ Walls ❑ d ❑ ❑ ❑ J STREET ADDRESS CITY STATE ZIP Signed I ALLER COMPANY N t d s r WWWF� •i *' a '- , l ' I ssE�..c y �^ '�i Ass—s it 1' ..=Hi �'. 1 ..� �` = %� wA �1. I ..r+ ..'„ I�+ ..Ay hl , 4r . tines•. -#-. ti tr �j,� 1..-",.A-c�.1 :tn i101. 1 etu ,. _ Ar4.� �rsN -Y '' x :Mt'M^: y;.s:. �=))�� !M tlr:, Y fir; ,,yj�t�r,=. ,•,�j� , . .��+A�iIX� ,..:•� ;�. 'b.^4 .Ls NN �VJR �) 9.'�;;�...L..- � 1� l�!1 ! t:+:I'. NMq `f1 :Sji.. rill f �• t'�� MANUFACTURED HOME 0 o CONCRETE MECHANICAL rn 0 CD Footings !Setbacks Date /o - 2 B y '1 Ribbons O Gas Piping 0o Interior Date By Interior-Date � By Date By Z Exterior Date ZZ (y�( By +r�j� Exterior-Date ' Oq B X Set-up r Point Load/Isolated Footings INSULATION Date By X BG i SLAB INSULATION M Date s ZZ1t)Gt. By w Data By FIRE DEPARTMENT Z Foundation Walls Floors Date By Date ,f'-Z -p BY2�1 Data By DECKS FRAMING We Date By Date /� - By Dat By PROPANE TANKS PLUMBING vau Date By Date By OTHER Groundwork Attic Type: f� Date By Date By Data ->- Z C-v d7 By f D.W.b DRYWALL Type: Date b _© By Int Brace Wall Date By 00 v gate By FINAL INSPECTION 0 CD Water Line Fire Sops ration C Date By Date By Date VI Z� �( By O m 1p Pass or Request Inspect. o 0 Type of Insp. Fail Date Date Done By Comments W a Y � tL �sy S ai p`t 2 0� L4�� CD vcl � 1 d 3S 'Z , ,ZS �P/�� '� �/ss o-�•o�' ,o-vim% LEI GP9 CS k '0/(b 11 /C, LACK n� Rsj L{ Ii 11 4 z1 0 30 (12/2/2010) Debbera Coker- Fwd: Insulation Certificate Page 1 From: <lorend56@aol.com> To: <DLC@co.mason.wa.us> Date: 12/2/2010 11:42 AM Subject: Fwd: Insulation Certificate f Attachments: Dell Laser MFP 1815_20101105152331.pdf Debbera, I am sending this per our converstion. As soon as I receive the statement from Charlene I will send it to you as well. Thanks for the cooperation. Loren Deaton -----Original Message----- From: Stephen Fogelman -284-5 Tacoma -Washington <Stephen.Fogelman @mascocs.com> To: lorend56 <lorend56@aol.com> Sent: Sat, Nov 6, 2010 2:40 pm Subject: Insulation Certificate Loren, Here is the insulation certificate per your request. Regards, Stephen Fogelman MASCO CONTRACTOR SERVICES DBA - GALE CONTRACTOR SERVICES CELL#253-405-6477 FAX # 360-895-0622 DISCLAIMER: The information in this electronic mail message is sender's business Confidential and may be legally privileged. It is intended solely for the addressee(s). Access to this Internet electronic mail message by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution or any action taken or omitted to be taken in reliance on it is prohibited and may be unlawful. The sender believes that this E-mail and any attachments were free of any virus, worm, Trojan horse, and/or malicious code when sent. This message and its attachments could have been infected during transmission. By reading the message and opening any attachments, the recipient accepts full responsibility for taking protective and remedial action about viruses and other defects. MASCO is not liable for any loss or damage arising in any way from this message or its attachments. u'a-0 PERMIT NO. MASON COUNTY BURN PERMIT APPLICATION J 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 a;o4 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 •www.co.mason.wa.us APPLICANT IyFORMATg N CONTRACTOR I, F MATI Ownerr ,�=� -� Company Nam Mailing Address 3935 Nrr 1s91'e Mailing Address City State -/V'1- Zip Code r�'�ia City State Zip Code Phone 34 c 3 77 97ils Other Ph. 3(_-v- 7 7n2 Phone Other Ph. Lien/Title Holder 519m'-- /5 rc_A/&,< Contractor Reg. # Exp. E mail Address S� P/90Z . cow E Mail Address Drivers DOB Drivers Lic. # DOB PARCEL NUMBER - Sec. Town _Rng.�_Fire District Site Address(Please include street name, number and city) �/ ����' 4�� ro ��Y a <�/-2 Direction site 1�,914_s ,L19Kc- /zd (A,,lc,✓ ��/ a�nJ �l�4�KiY�4t✓,c CT Parcel w-ithin 200'of Saltwater❑ Lake❑ River/Creek Pond❑Wetland ❑Seasonal Runoff❑ Stream❑ Slopes or Bluffs> 15% Is property flagged or addressed prior to inspectior No-Will timber be cut and sold in parcel preparation? Yes Reason for land clearing: 41,r1'7 f r3c///-v in)e, Is this site being converted or replanted? Yes / o Does site require FPA or 6 yr. Moratorium? Yes/ o ` The person in charge of the fire may be liable for the cost of fire supression if the fire gets out of control or, if it becomes necessary to extinguish the fire as a result of enforcement action. Open burning shall be prohibited during any period of impaired air quality as designated by the Olympic Region Clean Air Agency, or during extreme fire danger due to dry weather conditions as designated by the Mason County Fire Marshal's Office.Information hotline(360)427-7799 Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action? Yes(tNo Burning is authorized subject to the following conditions: CfValid permit must be on site while burning. RThe following materials are prohibited and must not be burned: Garbage,dead animals,asphalt, petroleum products, paints, rubber products, plastics, paper, cardboard,treated wood, construction/demolition debris, metal, or any substance(other than natural vegetation)that normally releases toxic emissions, dense smoke,or obnoxious odors when burned. 0AII materials must originate from the property on which the burning is to occur. ®The fire must not create a nuisance from smoke, obscure visibility on public roads and highways,or endanger life and property. IMaximum pile size is twenty(20)feet in diameter, a minimum ten (10)foot firebreak must be constructed around each pile. Each pile must be at least one hundred(100)feet from any structure, at least fifty(50)feet from standing timber. Do not burn if wind is blowing more than seven(7)miles per hour. 'Do not burn if wind is blowing from (direction) #A responsible adult and eqWipment shall be required to be on site and in attendance at the fire while burning. —On site water required: es ❑ No Provide EXCAVATOR/15OZ R(with a fire extinguisher)on site with qualified operator. Provide 24 hour fire watch. - k I'Fire must be completely extinguished within three(3)days after ignition. !! Fan required L A w' LWI z � °.�.:. ❑Other ;a Upon completion of above conditions,applicant must call(360)427-9670 Ext.262 for inspection prior to burning OWNER/CONTRACTOR Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the neces- sary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property for review and inspection. rmit/application becomes null and void if work is not completed within 30 days. Permit includes two (2) inspections mapmum, addition ions requir f rxty four(64)dollars per inspection. X - Date: w��Dwners Representative/Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Dat DEPARTMENTAL REVIEW APPROVED DENIED NOTES Fire Marshal FEES Burn Permit Fee Site Inspection Violation Fee State Fee Pre-Paid at Submittal Other EXPIRES: Date: Inspector TOTAL FEES