Loading...
HomeMy WebLinkAboutBLD2006-01285 Garage, Den - BLD Permit / Conditions - 8/31/2006 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 tooShelton, WA 98584 too RESIDENTIAL BUILDING PERMIT BLD2006-01285 OWNER: GENE JOHNSON RECEIVED: 7/20/2006 CONTRACTOR: LICENSE: EXP: ISSUED: 8/31/2006 SITE ADDRESS: 841 E SODERBERG RD ALLYN EXPIRES: 2/28/2007 PARCEL NUMBER: 122185000024 LEGAL DESCRIPTION: LAKELAND VILLAGE#12 PHASE II LOT: 24 PROJECT DESCRIPTION: DIRECTIONS TO SITE: add attached garage and den Enter Lakeland Villiage on Homestead , right on Old Ranch Rd to right on Soderberg to end. General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: V-B Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U-1 Lot Size: Deck: Type of Work: ADD Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building: Garage-Attached 390 Valuation: Building Height: 24 Occ. Status: Basement: addition 353 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: N 20.0 Ft. Shoreline: Ft. Water Body: Rear: S 108.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: E Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: W 5.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee CMH 7/20/2006 $319.96 B12006000 Planning Review Fee CMH 7/20/2006 $155.00 B12006000 ADJUST--Plan Check Fee RTB 8/2/2006 -$13.13 612006000 Building State Fee RTB 8/2/2006 $4.50 b12bb60t)0 Building Permit Fee RTB 8/2/2006 $472.05 B12006000 Total $938.38 BLD2006-01285 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2006-01285 CONDITIONS FOR BLD2006-01285 1) All other necessary permits from Mason County, Washington State and/or Federal Agencies that are re I�Id for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X 2) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted: 'I addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Department i to any further inspections being performed or approvals granted. X i 3) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections, l /� X r` 4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of p�' ed documents will result in failure of required building inspections. X 5) This struc;ure"11 approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit s I),be/applied for, reviewed and approved prior to the change. garage portion only addition uses existing heat. X t r� 6) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X (f 7) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval wi not,be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Building ent prior to any further inspections being performed or approvals granted. X BLD2006-01285 Please referto the following pages for conditions of this permit. 2 of 4 8) Washington State Energy Code Compliance has been approved using the following: Heat Typ,_. Iectric or other fuels, Compliance Method: IV, Window (Max U-Factor):0.40, Skylight (Max U-Factor):0.58, 'Doors (' / ax U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X 9)_ Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical cope work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 10) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If, ents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charge gall be collected by the Building Department prior to any further inspections being performed or approvals granted. X ' 11) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State ofT/as gton. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit r a i�n. X 12) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinan or gulation, must be reviewed and approved by Mason County prior to construction. X 13) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the in�rn tional codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspect ' fbe made prior to requesting additional inspections. X /. i' 14) All property lines shall be clearly identified at the time of foundation inspection. X ' 15) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a.fin I inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason Qc I rdinances and building regulations. X 16 All permits e� ire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for P P Y P Y P Y P 9 Y action for, rnot exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder�iav/l p�ev nted action from being taken. No more than one extension may be granted. X ( i BLD2006-01285 Please refer to the following pages for conditions of this permit. 3 of 4 17) Pressure ood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connecto , a�yru ashing. Install metal connectors approved for contact with the new types of pressure treated material. X /�� 18) Appr r imensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 19) This paf s Gated in a smoke management zone. Please contact a fire warden at(360)427-9670 ext. 459 for further information. X 20) Landing nd,Lairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "App}r6 i Plan" to ensure these structures are shown and meet the setback conditions listed. X % 21) By d In ti i n propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these tGr meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progressj7spection.The own,oi7br the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property 6j4l structure r rev nd inspection. 11 OWN ER OR AGENT: �� DATE: BLD2006-01285 Please referto the following pages for conditions of this permit. 4 of 4 ±�'r•,r W o CONCRETE MECHANICAL MANUFACTURED HOME lv� N o Date BY rn Footings I Setbacks Ribbons Z Gas Piping Cl) Interior Date B Interior-Date By Date By � 00 Exterior Date Exterior-Date B Z Point Load I Isolated Footings INSULATION Date By BG I SLAB INSULATION m Date By Data By FIRE DEPARTMENT m Foundation ails Floors Date By Date Dana 13 DECKS FRAMI G Walls Date By Date - 9 B Data • r'Q -� Q By PROPANE TANKS PLUMBING vault Date By Date By OTHER Groundwork Attic Date -�4 B Type- Date ray Date By D.W.v DRYWALL Type: Date By Int Brace Wall Date gy W Date By FINAL INSPECTION p Water Line Fire Separation tV Date By Date By Date By p m to Pass or Request Inspect. o Type of Insp. Fail Date Date Done By Comments t i Z Ali. 16)Na> W 3v1(r. L�OC_ 311 t r5 Loy cc jolt su 9T�u 2. n r�- LED V P Z t'/Z(IZ MCI: REA SF rc S c y Ei KF- C✓1w Fc� Z'2y-37 -Z-67 Ec, T G r\fl S � fai m owil 0 IPMason County Dept. of Community Development Mason County Bldg. 3 426 W. Cedar P.O. Box 186 (360) 427-9670 Local (360) 482-5269 Elma Shelton, WA 98584 (360) 275-4467 Belfair 14 Notice to Obtain Final Inspection November 12, 2008 GENEJOHNSON 841 E SODERBERG RD ALLYN WA 98524 Case No.- BLD2006-01285 Parcel No.: 122185000024 Proiect Description: add attached garage and den The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Building Code or the code your permit was issued and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from the date of this letter. Failure to contact our office to make the necessary scheduled inspections will result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $68.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you will be charged $68.00 again, per inspection until final inspection and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 595. Sincerely, 1 Rich Todd Balderston Mason County Department of Community Development Cc: Property File November 12, 2008 BLD2006-01285