Loading...
HomeMy WebLinkAboutBLD2019-01408 SFR - BLD Application - 12/11/2019 MASON COUNTY COMMUNITY SERVICES Permit No: PERMIT ASSISTANCE CENTER: •BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL U y■� (�615 W.Alder t, ILINC Phone Shelton:(360)427-9670eext 352toFax.,(360)427-7798 Phone O�V 2019 Belfair.(360)275.4467•Phone Elma:(360)482-5269 BUILDING PERMIT APPLICATION 615 W. Alder Street PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: Harbor Custom Development,Inc NAME: Harbor Custom Development,Inc MAILING ADDRESS: 11505 Burnham Dr,Ste 301 MAILING ADDRESS:11505 Burnham Dr,Ste 301 CITY:Gig Harbor STATE: WA ZIP: 98332 CITY: Gig Harbor STATE: WA ZIP: 98332 PHONE#1: 253-649-5216 PHONE: 253-649-5216 CELL: 253-7404268 PHONE#2: 253-740-4268 EMAIL: shawn@harborcustomhomes.com EMAIL: shawn@harborcustomhomes.com L&I REG# HARBOCH813P6 EXP. 10/0212021 PRIMARY CONTACT: OWNER® CONTRACTOR 0 OTHER❑ NAME Shawn Squier EMAIL shawn@harborcustomhomes.com MAILING ADDRESS 1 1505 8umham Dr,Ste 301 CITY Gig Harbor STATE WA ZIP 98332 PHONE 253-649-5216 CELL 253-740-4268 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 122185200017 ZONING R-1 R/UGA/R-1 P LEGAL DESCRIPTION(Abbreviated) Amended Plat of Lakeland Village No. 14 FIRE DISTRICT 5 SITE ADDRESS 60 E Virgil Dr CITY Allvn DIRECTIONS TO SITE ADDRESS Lakeland Village Division 14 Crossroads: Soderberg Rd and E Eugenia PI/E Virgil Dr IS THE PROJECT WITHIN 300 FT OF SLOPES)GREATER THAN 14%: YES❑ NO[R IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Checkall thatapply): SALTWATER❑ LAKE❑ RiVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW® ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.) Residence IS USE: PRIMARY R SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2 HEATED STRUCTURE? YES(Whole Bldg)® YES(FaH[s]of Bldg)❑ NO❑ DESCRIBE WORK Build New Single Family Residence SQUARE FOOTAGE:(propose 1ST FLOOR Z C7 y sq.ft. 2ND FLOOR 0 sq.ft. 3RD FLOOR 0 sq.ft BASEMENT 0 sq.ft DECK sq.ft COVERED DECK Z6D sq.ft. STORAGE 0 sq.ft OTHER sq.ft. GARAGE-7SO sq.ft. Attached Detached❑ CARPORT 0 sq.ft Attached❑ Detached El MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER® / NEW 0 EXISTING❑ PLUMBING IN STRUCTURE? YES 0 NO❑ Ifyes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES NO[] EXISTING SQ.FF. EXISTING BEDROOMS PROPOSED BEDROOMS 3 TOTAL BEDROOMS 3 OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) x 'ha-1 /;;-o& 0& 9 Signature of OWNER(M&be signed by the OWNER) / /Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT !�L•l Z PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH MASON COUNTY COMMUNITY SERVICES Permit No.-?)1Gt'a 6(q •Q(�°�j • PERIT BUILDINGSI PLANNING STANCE CENTER. MARSHAL n.r D I L D • 615 W.Alder St-Shelton, WA 98584 www.co.mason.wams Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 DEC 1 2019 • Phone Belfair. (360)275-4467• Phone Elma:(360)482-5269 615 W. Alder Street PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: Harbor Custom Development, Inc NAME: Harbor Custom Development, Inc MAILING ADDRESS: 11505 Burnham Dr.,Ste 301 MAILING ADDRESS: 11505 Burnham Dr,Ste 301 CITY: Gig Harbor STATE: WA ZIP: 98332 CITY: Gig Harbor STATE: WA ZIP: 98332 111 PHONE: 253-649-5216 PHONE: 253-649-5216 CELL: 253-740-4268 2nd PHONE: 253-740-4268 EMAIL : shawnC@harborcustomhomes.com EMAIL: Shawn@harborcustomhomes.com L&I PEG# HARBOCH813PB EXP. 10/02/2021 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number): 122185200017 Zoning: R-1 R/UGA/R-1 P LEGAL DESCRIPTION(Abbreviated): Amended Plat of Lakeland Village No. 14 SITE ADDRESS: 60 E Virgil Dr CITY: Allyn DIRECTIONS TO SITE ADDRESS: Lakeland Village Division 14 Crossroads: Soderberg Rd and E Eugenia PI/E Virgil Dr TYPE OF JOB: NEW x ADD ALT REPAIR OTHER USE OF BUILDING Residence LOCATION OF FIXTURES/UNITS—IsT FLOOR x 2NDFLOOR BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Tne of Fixture No.of Fixtures Fees Fuel Type:Electric LPG X Natural Gas Ductless_ Toilets 2 Twe of Unit No.of Units Fees Bathroom Sink 3 Furnace 1 Bath Tubs 2 Heat Pump Showers 1 Spot Vent Fan 4 Water Heater 1 Propane Tank 1 Clothes Washer 1 Gas Outl is 5 Kitchen Sinks 1 Woo as ellet Stove 1 -Fireplace Dishwasher 1 Kitchen aunt Hood 1 Hose bibs 2 Dryer Vent 1 Other-Laundry Sink 1 Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permittapplication becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Signature of Ownerl D to DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT J%L PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 JBN Name Harbor Custom Development Parcel# 122185200017 BLD#,�i D I Q • � I�08 Inc � • L I N Li Mason County DEC 1 1 2019 Department of Community Development yy, Alder S� eet Small Parcel Stormwater Management Application/Worksheet (page Pl Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) keir The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail:P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone:(360)-427-9670 EXT. 352 Mail:P 0 Box 1666,Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 Name Harbor Custom Development, Parcel# 122185200017 BLD# Inc Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surfacez. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X � _ Driveways X _ X = Length of drive begins at the right of way X = Parking Areas X = X = �� Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) �-i 1 1 J? If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page I of 2 NOTE: PRINT ON 11" x 11" PAPER TO ACHIEVE 1" = 20' SCALE 102'-6" 54'-0" 4T-O" t23'-411 I 20'-0" 20'-13%" 26'-24" S 88 5S 44 E 203.51' Qm x x x x x x x O ui TYP. SILT FENCE D + 12019 cv (IF NECESSARY) P.C. STOCK PILE I L v d. Alde ------- cq - E REAR 0 FACE OF EC OF 1 h DEGK POSTS W I N HOUSE / ° LOT 112018 "A" N \ �L GONG. STAIR S.S.S. LANDING CHAR. RIGHT z `- A'. w / c PLANNING TYP. EDGE OF ALT. EAT Q �� �\O r DISTURBED AREA 0' z Pt!M ADDER ® Q �� 0 �40 / Lu \` THREE CAR GARAGE i 2'- w 3 v6 ENT. 0 N FACE OF p O _ GARAGE LL 33 I=71 PLANNI � lcr N EDGE OF 10 a %LONG WALK '•*� GONG APRON 'LL SETBACKS ARE ME PFE Mous 5 `A 6/J FROM THE FURTHB$9E OF FOR Ho- �,, FRQJECTION OF THE BUILDING ENT, o ryo� 4" P.Y. . FROM DOWNSPOUT CONNECTION AT HOUSE A 10.01 TO STORM R 50.00' AS ALT D 80 13 it ZONING R-IP(40% ALLOWED IMPERVIOUS) DRI AY IF QUESTIONS, PLEASE CALL PAT McCULLOUGsH U � (LAKELAND STORM ENGINEER) 16'-0" J W (360)-215-1384 CELL: (360)-204-2356 v z a 0 �a a LOT = 13213.1 S.F. p z HOUSE = 3498 S.F. (INCLUDING OVERHANGS) �P e m� FRONT WALK = 66 S.F. (EXPOSED) U _2 DRIVE = 536 S.F. (EXPOSED) REAR PAD = 11 S,F, (EXPOSED) hQ TOTAL = 4113 S,F, = 31.13 99 IMPERVIOUS COVERAGE DISTURBED AREA = 8600 S.F, 659s (CLEARING LIMITS) ut r_ z �r SCALE: 1" = 20'-0" lK ], Q /z (A m 0' to' 20' ��I C;o Inams r �► m 40' a0 F�onF � $w�� V� 5' r G DRIVE 35 4•-37 y S�I 37 53 54 SHIN O2• i6 I 1 J 0 t• I O !ID Y cj N �� � 11 as 2 4t APPROVE® b3 µ J -1 MASON COUN o.Y DCD PLANNING � a OOLFCO� � � SITE PLAY, :'�FQtJIREb TO BE ON SITE FvtuRE — 9b = U CHANGIE'. UBJET TO APPROVAL DEv=PME 61° •�-j r „n cn � iDat� 1 L 12 '� a' ' �• I r' s Lakeland Village °� ,b r PLAN " 2018 0 � 11 ELEY. A Division 14ll 2 a RevlGfom �I •s 4 N Dote: Dreun N. ti I� Y 7 � ay u a•"� ul•au OPEN APACE r 2�23 rQFi Checked by: is Y 22 .q D"; 'I is-Is DRAINAGE Y] 21 4• 3 P= to Y't� 2 1 Shheet. Y2 Y•� t7 OF N�'OIh AN�t! NOTE: PRINT ON 11" x 11" PAPER TO ACHIEVE 1" z 2O' SCs4L1—= 102'4o" ,t 54'-O" 41-0" .!r '-10" I It 23'41 201-0" 20'-594 26'-2144" Q w S 88 59 44 E 203,51' x x x x x x �x x x x m 4 TYP. SILT FENCE O NO cd (IF NECESSARY) P.C. STOCK PILE t`+ E NVI R 0 s FACE OF EC O REAR / HE//,,��, �\ _ DECK POSTS w I T iI N HOUSE y!j�, — Q. �oT �� 20�8 II A II W N U GONG. STAIR fi Y W �\ a LANDING GAR, RIGHT z \\ TYP. EDGE OF N ALT, EAT r DISTURBED AREA V %3 z Pl!M ADDER 0 It In E--� DEC1 \\` 0 THREE CAR 'n 2019 GARAGE Lu 615 W. �. _ � 3/9 �`. 2 ENT. � � FAGS OF n � GARAGE U. 3�� N :r u- AP P ROV _ � _ in cv EDGE OF DEC 19 2019 FACE OF HOUSE aal CONC WALK GONG APRON y 5 IA 614 FACE OF PORCH C040M ENVIRONMENTAL HEALTH w G E N MASON g ENT.. Q QI to LYC 4" P.Y.0 FROM DOWNSPOUT N� CONNECTION AT HOUSE A 10.01 TO STORM R 50.00' AS ALT D 80 13 11 ZONING R-1 (40% ALLOWED IMPERVIOUS) DRI . WAY IF QUESTIONS, PLEASE CALL PAT McCULLOUGH U (LAKELAND STORM ENGINEER) 1360)-21=✓-1384 CELL: (360)-204-2356 z 3 O � LOT - 13213,1 S.F, o�y o HOUSE It34W S,F. (INCLUDING OVERWANGS) �p of FRONT WALK - (o(o S,F, (EXPOSED) U 2 DRIVE Is 538 S.F. (EXPOSED) REAR PAD - 11 S,F, (EXPOSED) TOTAL - 4113 S,F, - 31,13 96 IMPERVIOUS COVERAGE DISTURBED AREA Is 8600 S,F, 6596 (CLEARING LIMITS) I Ce, z N�N I \ \'\1ex z SCALE: 1" = 20'-0° O' ���- aol doa8S \\ � r 01 10' 20' &0' \\ s Q 40' , \� 0 O I- _ dO F�on f $1�L z 51 Deus - o 14 / u 0 � � ._Y G RPo'E 23 of 27 2e �~f I zz b7 154 so IN 2e iD — it I I1� O !f es ae I O JD y 1 LeA`N C U II 4 z � W µ r1 I e! r' ° FUTURE as x U DE4ELOPME Lakeland Village ' "' „ y PLAN • 201S Division 14 ? r' �1iI ELEV, "A s e I ROV11610m: �s• Data: Draw, e 7 2S 'fYr 92 Dr~I bq, W.JIN I t 2I OPEN SPACE 7p Checked by, e i'® 22 22 Fr�„P Date,II-113-19 DR41NiGE e J f3 Zf ,y3 FOND }0 1+15 I� sheet: 12 1e 17 r OF WO 9