HomeMy WebLinkAboutBLD2014-01098 Furnance - BLD Permit / Conditions - 1/23/2015 r ' Inspection Line(MU)42/-/2ti2
C185W
�TFMASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg.426 W. Cedar
Shelton, WA 98584
RESIDENTIAL BUILDING PERMIT
BLD2014-01098
OWNER: PAMELA BERTRAND
CONTRACTOR: OLYMPIC HEATING & COOLING 360-426-9945 LICENSE: OLYMPHC986BA EXP: 1/1/2016 RECEIVED: 12/24/2014
SITE ADDRESS: 91 E SPRINGWOOD DR SHELTON ISSUED: 1/23/�015EXPIRES: 7/23/2015
PARCEL NUMBER: 420125500025
LEGAL DESCRIPTION: SPRINGWOOD LOT: 25
PROJECT DESCRIPTION: ECTIONS TO SITE:
FURNACE S LTON SPRINGS RD, R ON ISLAND LAKE RD, FOLLOW TO
SP INGWOOD DR
General Information Constructi ccup c Information Square Footage Information
No. of Bedrooms: ype onstr.:
Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Lot Size: Deck:
Type of Work: MEC Fire Dist.: 11 No. of Stories: cc. Load: Building:
Valuation: Building Height: cc. Status: Basement:
Manufactured Home Information Se Info mation Shoreline& Planning Information
Make: Length: Ft. Front: Shoreline: Ft. Water Body:
Rear: F SEPA?:
t. Slope: Ft.
Model: Width: Ft. Side 1: Ft. Shoreline Desig.:
Year: Serial No.: Side 2: Ft Comp. Plan Desig.:
Plumbing Fixtures Mech fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Furn <10 1 Building Special inspection GMM 12/24/201 $73.00 S2201500000001
Mechanical Permit Fee GMM 12/24/201 $ 18.30 S2201500000001
Mechanical Base Fee GMM 12/24/201 $28.50 S2201500000001
Total $ 119.80
BLD2014-01098 Please refer to the following pages for conditions of this permit. Page 1 of 4
CASE NOTES FOR
BLD2014-01098
+� CONDITIONS FOR
BLD2014-01098
low
1) Contractor registration laws are governed under RCW 18and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are p ential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647 2. The person signing this condition is eithitv�omeowner, agent for the owner or a registered contractor according to WA state law.
X v el
2) ALL FURNACE INSTALLATIONS SHALL MEET Tdq MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON
STATE ENERGY CODE (WSEC). ANY PORTION OF TTIE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM
STANDARIA SET FORTH IN THE WSEC AND IWNATIONAL MECHANICAL CODE.
X
3) All construction must meet or exceed all local ordini(ces and the international codes requirements as adopted and amended by Mason County and the
State of W hington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit tion. J
re
X x
y
}
BLD2014-01098 Please refer to the following pages for conditions of this permit. Page 2 of 4
L
r -4) Installation of heating equipment in a smgie-tamoy resiaence snap meet the requirements of the current ILuu/vvbtzu K4W, appncaole sections of the
IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC
systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be
available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts
shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets
equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance
to IECC/WSEC Section R403.2.2 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are
available on at the WSU-Energy Program website titles "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct
9Y 9 9 9 9 ( 9 )
tightness testing is not required if the air handler and all ducts are located within the heated space.
X 4K
5) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been
identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or
operator has ob ed written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
X
6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County or nces and building regulations.
X 4
7) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have pr ed action from being taken. No more than one extension may be granted.
X
BLD2014-01098 Please refer to the following pages for conditions of this permit. Page 3 of 4
OWNER / BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PER T APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
Si ture Date
6� OWNER - REPRESENTATIVE - CONTRACTOR
Print Na a (Circle one to indicate)
i
I
I
I
I
I
'I
I
BLD2014-01098 Please refer to the following pages for conditions of this permit. Page 4 of 4
12/24/2014 08:39 3604277466 OLYMPIC HEATING PAGE 01/02
MASON COUNTY PERMIT NO.
W DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING.PLgNNING&FIRE MARSHAL
WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352
Mason County Bldg. Ill,426 West Cedar Street (360)275-4467 Belfair exL 352
S, PO Box 279,Shelton,WA 98584 (350)482-5269 Elme ext. 352
PLUMBING & MECHANICAL PERMIT APPLICATION
OVY'NE NFOR IATION: i-6A LJ_ CONTRACTOR INFORMATION:
NAME: N
MAILING ADDRESS: \A! MAILING SS:
CITY(-))0-M Ri a STATE: IP: Z CITY lf,.hq STATE:\i _ZIP:
PHONE:'43Z-9000\)P9E CELL: PHONE• Q-Y1 CELL:
EMAIL: HAS:/tal.t EMAIL
L&I REG#crV_VAetjc',q9j C,U EXP.
PARCEL IN)F'ORMATION:
PARCEL NUMBER(12 DIGIT NUMBER): f j 7p 1 Z SEE` nc S
LEGAL DESCRIPTION(,A BREvzAY D):. rsntn,u�c �7 �!• , 5
SITE ADDRESS: 91 r ; fir;oe CITY:,ShP0�oN
DIRECTIONS TO SXTE ADDRESS:
TYPE OF JOB
NEW AbD ALT REPAIR OTHER USE OF BUILDING
LOCATION OF FIXTURES/UNITS-1sT FLOOR 2NDFLOOR BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NLMOER OF EACH) MECHANICAL UNTTS
Type of Fixture No_of Fixtures Eeej Fuel Type-Electric LPG Natural Gas Heat Pump
Toilets jpe of Unit
Bathroom Sink Furnace
of Units Fees
Furnace
Bath Tubs
Heatpump,
Showers Spot Vent Pan
Warer Heater Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks � Wood/Gos/1'ellet Stove
Dishwasher Kitchen Exhaust Hood
Flosebibs Dryer Vent
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor, I further decare
that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including
any easement holder or parties of interest regarding this project The owner or authorized agent represents that the information provided is
accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This
permit/application beoomes null&void if work or authorized construction Is not commenced within 180 days or if construction work is
suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
X )
*05Ap icant B�Owner/Owners Re resents Contracto
Print Name (indicate which on®)
:A`�A'RTMEr1T„A.I.1�.'Ir'JEVY�)�: � � '& Y''�.•._,�..._•.,,,may
BUILDING DEPARTMENT
PLANNING DEPARTMMNT
FIRE MARSHAL
2015
426 vV, CEDAR ST.
o CONCRETE MECHANICAL MANUFACTURED HOME m
0
Footings/Setbacks Gas piping By Ribbons —1
o Interior Date By Interior-Date By Date By
Exterpr Date By Exterior-Date B Z
__— —_-- Set-up p
Point Load!Isolated Footings INSULATION Date By
BG I SLAB INSULATION -- D
Date By Data By FIRE DEPARTMENT 3
Foundation Walls Floors Date By m
r
Date. By Data By DECKS D
FRAMING Walls Date By
Date By Data By PROPANE TANKS
PLUMBING Vault Data By
Date By _ OTHER -----
Groundwork Attic —
Date By Date By Type
Date By
DRYWALL
D.W.V Type-
-0 Date 8y Int Brace Wall Date. ay W
CD v Date By FINAL INSPECTION p
y Water Line Fire Separation iV
m
Dale By Dale By Date By
N 4h.
g Pass or Request Inspect. c
s Type of Insp. Fail Date Date Done By Comments
CD
a 00
0
f
c0
CD
ch
0
0
0
n_.
o'
0 -- --
y
O
—w
CA
(D
3
N
(L]
(D
0