Loading...
HomeMy WebLinkAboutBLD2005-01696 SFR - BLD Permit / Conditions - 10/25/2005 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2005-01696 OWNER: MARK MILLER RECEIVED: 9/27/2005 CONTRACTOR: MARK MILLER LICENSE: MARKMMC959KK EXP: 5/12/2007 ISSUED: 10/25/2005 SITE ADDRESS: 121 E BOARDWALK SHELTON EXPIRES: 5/3/2006 PARCEL NUMBER: 420122190170 LEGAL DESCRIPTION: TR 17 OF NE NW S 6/68 LOT: 3 OF SP#621 PROJECT DESCRIPTION: DIRECTIONS TO SITE: SFR(STOCK PLAN 2003-0102) HWY 101 RIGHT ON SHELTON SPRINGS RD LEFT ON BOARDWALK TO SITE ON LEFT ADJACENT TO TRANSMISSION SHOP General Information Construction &Occupancy Information Square Footage Information No.of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No.of Bathrooms: 2 Occ. Group: R-3U Lot Size: Deck: 25 Type of Work: NEW Fire Dist.: 11 No.of Stories: 1 Occ. Load: Building:1,956 Garage-Attached 521 Valuation: Building Height: 20 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: E 30.0 Ft. Shoreline: Ft. Water Body: Rear: W 50.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Shoreline Desig.: Side 1: N 15.0 Ft. Year: Serial No.: Side 2: S 20.0 Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KS 9/27/2005 $285.51 S12005000 Hosebibs 3 Furnace<100K 1 Planning Review Fee KS 9/27/2005 $155.00 S12005000 Kitchen Sink 1 Ventilation Fan 3 Address Fee GMM 10/3/2005 $140.00 522005000 Lavatories 2 Heat Pump 1 EH Plan Review CEW 10/5/2005 $75.00 522005000 Showers 1 Dryer Vent 1 Building State Fee ARC 10/20/200 $4.50 S22005000 Water Closets (Toilets) 2 Building Permit Fee ARC 10/20/200 $1,234.55 S22005000 Water Heaters 1 Mechanical Fee ARC 10/20/200 $39.65 S22005000 Bath Tubs 2 Mechanical Base Fee ARC 10/20/200 $23.50 S22005000 Clothes Washer 1 Plumbing Fee ARC 10/20/200 $82.00 S22005000 Plumbing Base Fee ARC 10/20/200 $20.00 S22005000 Mechanical Fee KS 1/25/2006 $25.45 S12006000 Mechanical Base Fee KS 1/25/2006 $7.50 S12006000 Total $2,092.66 BLD2005-01696 Please refer to the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2005-01696 CONDITIONS FOR BLD2005-01696 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X V, \---- 2) The internatioanl code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. XV__ %-- 3) OWNER MUST SHOW PROOF OF SATISFACTORY WATER SAMPLE AND WELL LOG PRIOR TO TEMPORARY/PERMANENT OCCUPANCY OF THE RESIDENCE. X i ` L-., 4) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X �4, — 5) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established. X U-_ 6) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. XL__ L___,. 7) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X �.., 8) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X BLD2005-01696 Please refer to the following pages for conditions of this permit. Page 2 of 4 9) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X I' 10) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 11) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X ' k-- 12) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window(Max U-Factor):0.40, Skylight(Max U-Factor):0.58, Doors (Type/Max U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X �Lv L-._- 13) Stock Plan Identification number: 2003-0102 This project is approved subject to the provisions identified the Mason County Stock Plan Policy. The site plan approved by the Planning Department, original building plans, and all attachments approved by the Mason County Building Department shall be available for the Mason County Building Inspector at each required inspection. Xk~-. L. 14) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X L-- 15) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X kL 16) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X BLD2005-01696 Please refer to the following pages for conditions of this permit. Page 3 of 4 17) All changes to"approved"building plans that effect compliance with the international codes as amended and adopted, or any other Mason County , ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X �^ 18) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building IInspeecct'or shall be made prior to requesting additional inspections. 19) All property lines shall be clearly identified at the time of foundation inspection. X �,—V 20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X (^--- L,_. 21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. XL-_ `_` 22) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. XL, — This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a ress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Tqn County access to he described property and structure for re iew and inpection. OWNER OR AGENT: "� DATE: n BLD2005-01696 Please refer to the following pages for conditions of this permit. Page 4 of 4 17) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. Tie construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 18) All property lines shall be clearly identified at the time of foundation inspection. X 19) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X 20) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 21) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 22) Stock Plan Identification number: SET UP 2003-0102 This project is approved subject to the provisions identified the Mason County Stock Plan Policy. The site plan approved by the Planning Department, original building plans, and all attachments approved by the Mason County Building Department shall be available for the Mason County Building Inspector at each required inspection. X 23) Installation of heating equipment in single family residences shall meet the requirement of the current WSEC. The furnace to be installed shall not exceed 200% of the heating design load or prescriptive requirements of Chapter 9. Furnace efficiency shall be .78 AFUE or higher or rated 80% combustion efficiency. All ducts shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems or tapes installed in accordance nstallation instructions. Duct tape is NOT permitted as a sealant on any ducts. Ducts in unheated spaces shall be insulated to R-8. This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended fora period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described prop structur view and ins ion. OWN ER OR AGENT DATE: BLD2005-01695 Please refer to the following pages for conditions of this permit. 4 of 4 1 00 o CONCRETE MECHANINAL MANUFACTURED HOME Footings!Setbacks Date 7/S/ B Ribbons rn Date j 3 0(5 By !.(�� Gas Piping Date By 0) Foundaflon Walls Date By Set-up Date By INSULATION Date By BG I Slab Insulation Floors FINAL I NSPECTION Date By Dates � i Dabs By FRAMIN _ Walls FIRE DEPARTMENT Date Z lot Date B)SL Date By PLU BIG Attic OTHER Groundwork Date Z By Date By WALLBOARD N LING Date ��� � ey CD D.WN _.. m Date i (,Y.j B a� m water ine FINAL INSPECTION -. Date t 3I By Date 4 By' L4 Date By Type of Insp. Pass/Fail Request Date Inspect. Date Done By Comments CD r n 0 CD oro �A% 3o Ub rLi D(�L c Y ;4: 4IMP,in �r b 0 X N rimsuK�'It 2 o7/11 4Lb 1 3 92 n i �t - - x Kira. r'1 �'�s - ,:�o I tv CD cc 0 MASON COUNTY PERMIT NO��� �) BUILDING PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, / A 98584 Shelton (360) 427-9067 0 eBelf it (v 60) 2 75-4467- Elma (360) 482-5269 CONTRACTOR INFORMATION L! C APPLICANT INFORMATION C Company Name !" -,1 I_c Ll i"(� �� I Owner .r. e N2 Mailing Address Zip Code Mailing Address 3 City State City /X `A Lm P i A State Zip Code Phone Other Ph. 8<< —t o 7 IW� -Other Ph.4C�' ^/°1 M— k--WX1�.C`15`f Ku Exp. Phone____----- Contractor Reg. # Lien/Title Holder I s( 9 3 CD"�C C S-t. NeT E Mail Address DOB E mail address 2 Drivers Lic.# Drivers Lic.# t, I '° T-3 3 C(3 DOB Existing Septic SEPTIC/WATER SYSTEM INFORMATION - Connect System to New Septic___ d e— Connect to Water System 1 rt A4j UJI e u S Well Water System '� Name of Water System Fire District ----- PARCEL INFORMATION.12 Digit Parcel No °} f U � Legal Description OW sec t 3 T ��� ,t Site Address(Please include street name, street number and city) Directions to site Will timber be cut and sold in parcel preparationnke es No River/Creek -----Pond__-- Is property within 200'of Saltwater Stream________Slopes or Bluffs ] 15% Wetland Seasonal Runoff result Of a stop Wot Is this permit submittal the Notice,Correction Notice PRIMARY RESIDENCE SEASONAL ❑ TYPE OF JOB- New Add Alt Repair Other_ �v>� S r� Describe Work 1°l S Use of Building I `/� _2nd Floor —No. of Bathrooms�-Square Footage- 1st Floor�--- Sq.it. No. of Bedrooms Covered Deck�Other 3rd Floor—_.---Basement Deck Detached �.c _ Detached —Carport Attached Garage - I Attached d Model Year MANUFA CTU RED HOME INFORMATION -Make No. of Bedrooms No. of Bathrooms_—__---- Length -Width Serial No. Replacement Unit? Yes/No Type of Heat Purchase Price$ Certification No. Installer Name ti owledgerrierrt of O /BUILDER powledges submission of inaccurate information may result o theracto e re that I entitled to receive this rtes.If permission is such is by signature below.I dedare that I am the owner, dedare towners hat(have obtained the permission from ill on,I have obtained permit and to do the work as proposed in the application.in interest regarding this application or the work pro a information required from any easement kidder or any other party me owner or agent on own r re spection. permission from them to apply for this permit and conduct the work t theoabove described property an c� provided is accurate and grants oyes of Mason County acts N1 PROOF CONTINU O RK tS BY MEANS OF A PROGRESS INSPECTION Date X owner/Owners Representative/Contractor indicate whit one Accepted by: Date FOR OFFICIAL USE BEYOND THIS POINT NOTES DEPARTMENTAL REVIEW APPROVED DENIED Building Department Planning Department Environmental Health Department Public Works Department Fire Marshal FEES Site Inspection Buildin Permit Fee EH Review Fee Plan Review Fee 'pz .00 Plannin Review Fee Plumbin &Base F e 3 ' 1 Other Mechanical &646 fee State Fee Wood/Gas/Pelle# Love Fee EAJC, Pre-Paid at Submittal Violation Fee 3 TOTAL FEES Valuation$ t` 2 PERMIT NO._____ MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar-P.O. Box 186, Shelton, WA 98584 Shelton (360)427-9670-Belfair(360)275-4467-Elma(360)482-5269 n the web www.co.mason.wa.us Arc—) APPLICANT INFORMATION I CONTRACTOR I TIO Owner �'�v--- M(_L--e2 W��ST rv�vto- L.,ZC Company Name C � '_IL_LL iON ST-, LAC Mailing Address � 3 la 4-- ,)� - Mailing Address S a21� City (it-�4 �-P iA State 1A):A-Zip Code S' b City State Zip Code Phone `7 S`l -Cp-7 S(4—Other Ph. 4,�- `15 / Phone Other Ph. Lien/Title Holder Contractor Reg. # 1{-RkfvtwlCq �K ip _; E mail address �( `/ 3 1 -CO& , E Mail Address s l9 0"7 Drivers Lic.#_thl IU 101-r3.3.3 C13 DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No 01 7 Fire District Legal Description N 0 5-rCl(e— 1 2- --oJ n:L td O O c r R tJ VO Site Address(Please include street name, street numb and city) L. < Directions to site f-ro`"� 1-1 W 10 1 - T- v - -C e L--mH S PP-cn b_S e v S 1r e r\. L-C Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building _777 Location of Fixtures/Units- 1 st Floor f 0 2nd Floor Basement Garage Closet PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric—LPG_Natural Gas_Heat Pump_ Toilets 2 Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs .Z Heatpumps Showers I Spot Vent Fan _ Water Heater / Propane Tank Clothes Washer I Gas Outlets Kithen Sinks t Wood/Gas/Pellet Stove Dishwasher i Kitchen Exhaust Hood Hosebibs Z_ Dryer Vent / Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate infomiation may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONMUA'nn RK IS BY MEANS OF A PROGRESS INSPECTIOry. X �K G._A -t w Date: Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ �M. Group-Type Constr.- Planning Department Environmental Health Department FEES Plumbing&Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/ Pellet Stove Fee Other Violation Fee TOTAL FEES — ..vvv ic.of rAA wco vaju ROBS EXCAVATING LLC 0001 9011,70 V Ilk 570 '"DA RT RT G. WIN ......fi EXPIRES 08�0 pA ( j �4 - MIN 7p��� 001 60 'Ag� APP OVED �<< 6SON COUNT DCD PLANN SITE PLAN REQW F�p TO BE ON SITE, (� CHANGES SLJBJ CT TO APPROVAL �Y Tf�c_ — Date 10 �d Wtk C