Loading...
HomeMy WebLinkAboutCOM2008-00139 Building A- Notification of Incomplete Application - COM Letters / Memos - 12/8/2008 P�oN_STgTF�� MASON COUNTY o n° �, DEPARTMENT OF COMMUNITY DEVELOPMENT o N Planning Division N Y y P O Box 279, Shelton,WA 98584 o� 1864 (360)427-9670 NOTIFICATION OF INCOMPLETE APPLICATION December 08, 2008 DWIGHT MCKAY 590 E ISLAND LAKE DR SHELTON WA 98584 ° ' �' X > S/ Parcel No.: 420122190003 Hnn-ck. Proiect Description: Building A- Storage Building 7-10'x10' units & 5-10'x40' units Dear Applicant: You have submitted a permit application (case no. COM2008-001SQ) for proposed construction on development in the county. Upon review of your application, I have determined that the:contents of the application are incomplete or do not provide enough detail for review. Therefore, review of your application will not proceed until the necessary information.is provided (see the comment section of this letter for details.) Once the information is submitted and the application is complete, I will continue to process your application accordingly. If the additional information is not provided to the County within 180 days of this request, the application shall expire and no further action on the proposed development shall take place. Please contact me at (360) 427-9670, ext. 287 if you have questions. S' c y, Pam Bennett-Cumming Land Use Planner Mason County Planning Department 12/8/2008 Page 1 of 2 COM2008-00139 NOTIFICATION OF INCOMPLETE APPLICATION 12/8/2008 Case No.: COM2008-00139 Comments: This Letter of Incompleteness applies to COM 2008-00139, COM2008-00140, COM2008-00141, COM2008-00142, COM2008-00143, and SEP2008-00157. In conducting initial review of your applications, the following issues were noted which will require correction and/or additional information to continue review. Mason County Development Regulations: Site is located within the Shelton Urban Growth Area (UGA). Self-storage units would be an allowed use. In the UGA, different types and intensities of use are sepatated from each other using Buffer Yards. Your proposed use is a Category V use. Adjacent uses are Category II uses. Therefore the proposed self-storage parcels require a 20ft buffer yard around the perimeter of the site, with three canopy trees, six understory trees, and 9 shrubs per 100 feet. The buffer yard may be reduced by 50% (to 10 feet wide), if the plantings are doubled. Because you propose a 1 Oft wide buffer yard, your plantings will be doubled. Stormwater Features in Buffer Yard - development configuration to fit on parcels. Your two sites are current) undeveloped, and you propose self-storage units specific to that site.Y p Y p p g p You will need to configure your development such that the buildings, accesses to and around the buildings, and your stormwater features, fit within the portions of your sites not already encumbered by your buffer yards, which you have already reduced to half the standard size. In order to fit the development on the parcel with appropriate fire and customer access, this may mean your building sizes may need to,be reduced accordingly. Other stormwater issues: Your engineered stormwater plan shows four self-storage buildings on two parcels (two buildings to a parcel). The project site plans show two buildings on one parcel and three on the other parcel. Your engineered stormwater plan and your proposal need to be consistent with each other, as well as being configured to fit within the parcel regulatory requirements. SEPA Checklist: Your SEPA checklist is being returned with this letter, for your completion. Right now it does not contain enough detail for an unfamiliar reader to understand the project. In addition some responses are not completed properly. For example, "none" is not an appropriate response to the question asking how you will reduce or control erosion, other impacts to the earth. You may want to work with your stormwater engineer for his assistance. Mason County Resource Ordinance Critical Aquifer Recharge Area Chapter 17.01.0880: Site is within a Category II Critical Aquifer Recharge Area. Recording of Title Notification is required. A blank title notification to gether ether with the Cha pter,apter, are enclosed. 12/8/2008 Page 2 of 2 COM2008-00139