HomeMy WebLinkAboutBLD2024-00505 Mechanical - BLD Inspections - 5/21/2024 INSPECTION CARD
Mason County
N 615 W. Alder St.
Building 8, Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
PERMIT# BLD2024-00505 PROJECT ADDRESS 26470 N US HIGHWAY 101 HOODSPORT, WA 98548
PARCEL# 323313300680 PROJECT DESCRIPTION REPLACE AIR HANDLER AND HEAT PUMP
OWNER ADDRESS PHONE
CONTRACTOR BRADLEY AIR COMPANY ADDRESS 123 E FAIRFIELD CT PHONE 360.426.1284
CONTRACTOR LICENSE BRADLAC8281-6 LENDER
INSPECTION 1. NSP D TE Comments INSPECTION INSP I DATE Comments
Mechanical/Plumbing Final
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
B DD2024-00505 MECHANICAL - RESIDENTIAL
PROJECT DESCRIPTION: REPLACE AIR HANDLER AND HEAT PUMP ISSUED: 05/02/2024
SITE ADDRESS: 26470 N US HIGHWAY 101 HOODSPORT
EXPIRES: 10/29/2024
PARCEL: 323313300680
APPLICANT: SUND SHARON J OWNER:
P O BOX 114
HOODSPORT,WA 98548
360-426-1284
CONTRACTOR: BRADLEY AIR COMPANY
123 E FAIRFIELD CTSHELTON,WA 98584
360.426.1284
GENERAL CONTRACTOR'S LICENSE: BRADLEY AIR COMPANY License: BRADLAC8281_6
123 E FAIRFIELD CTSHELTON,WA 98584 Expires: 06/26/2024
360.426.1284
FEES: Paid Due
Final Inspection $80.00 $0.00
Mechanical Fees $33.00 $0.00
State Fee-Residential $6.50 $0.00
Mechanical Base Fee $30.00 $0.00
Technology Flat Convenience $5.00 $0.00
Fee
Totals : $154.50 $0.00
FIXTURES
O.yt Mechanical Fixtures
1.0000 For each air-handling unit to and including 10,000
cubic feet per minute (cfm) (4719L/s), including
attached ducts.
1.0000 Heat Pump(s)
Printed by:Annie Wilson on:05/03/2024 08:48 AM
Page 1 of 4
w
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
MECHANICAL - RESIDENTIAL BLD2024-00505
REQUIRED INSPECTIONS
Mechanical/Plumbing Final Inspection
CONDITIONS
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED.
* All furnace installations shall meet the minimum efficiencies set forth in the current edition of the Washington state energy
code (WSEC). any portion of the mechanical system that is altered or replaced shall meet the minimum standards set forth
in the WSEC and international mechanical code.
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant one or more extension of 180 days, upon the receipt of a written extension request prior to permit
expiration. Letter must indicate that circumstances beyond the control of the permit holder prevented action from being
taken.
* The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency
(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos
containing materials have been identified and removed from the area to be demolished. Work shall not commence on an
asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B
Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
Printed by:Annie Wilson on:05/03/2024 08:48 AM
Page 2 of 4
T
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
MECHANICAL - RESIDENTIAL BLD2024-00505
• Exterior Unit must be elevated above the base flood elevation of 14 feet. All electrical must be protected from flood waters.
* This property has been identified in a FEMA(AE) Flood Hazard Area. SUBSTANTIAL IMPROVEMENT as defined in the
2021 International Building Code is any repair, reconstruction, rehabilitation, alteration, addition or other improvement of a
building or structure, the cost of which equals or exceeds 50 percent of the market value of the structure BEFORE the
improvement or repair is started. If the structure has sustained substantial damage, any repairs are considered substantial
improvement regardless of the actual repair work performed. The term does not, however, include either:
1. Any project for improvement of a building to correct existing health, sanitary or safety code violations identified by the
building and that are the minimum necessary to assure safe living conditions.
2, Any alteration of a historic structure provided that the alteration will not preclude the structure's continued designation as a
historic structure.
When Substantial Development has been determined future work including such items as change of use, additions,
alterations, and repairs are subject to the requirements of the 2021 International Existing Building Code and 2021
International Building Code Section 1612.
Mason County Flood Prevention Ordinance definition (MCC 14.22.040):
"Substantial improvement" means any repair, reconstruction, or improvement of a structure, taking place DURING A TEN-
YEAR PERIOD, in which the cumulative cost equals or exceeds fifty percent of the market value of the structure either:
(1) Before the improvement or repair is started, or
(2) If the structure has been damaged and is being restored before the damage occurred. For this definition "substantial
improvement"is considered to occur when the first alteration of any wall, ceiling, floor, or other structural part of the building
commences, whether that alteration affects the external dimensions of the structure.
This term includes structures which have incurred "repetitive loss"or"substantial damage" regardless of the actual amount
of repair work performed.
The term does not, however, include either:
(1)Any project for improvement of a structure to comply with existing state or local health, sanitary, or safety code
specifications which have been identified by the local code enforcement official, and which was in existence prior to the
damage event or improvement, and which are solely necessary to assure safe living conditions, or
(2)Any alteration of a structure listed on the National Register of Historic Places or a State Inventory of Historic Places.
All future work will be evaluated at the time and by scope and value.
Printed by:Annie Wilson on:05/03/2024 08:48 AM
Page 3 of 4
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
MECHANICAL - RESIDENTIAL BLD2024-00505
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or Authorized Agent: Date:
Printed by:Annie Wilson on:05/03/2024 08:48 AM
Page 4 of 4
MASON COUNTY Mason County Permit Center Use:
• COMMUNITY SERVICES FLD 202A - QQIO?5'7
Building,Planning,Environmental Health,Community Health
615 W.Alder Street—Bldg.8,Shelton,WA 98584 Date Rcvd
Phone:(360)427-9670 Ext.352 1 Fax:(360)427-7798
Ws
0
if
FDPO Develo ment Permit Application
Applicant: Contractor: APR 2 4 2024
DUANE TAHRAN - PM BRADLEY AIR COMPANY
Mailing Address: Mailing Address: 610 W.Aidder street
26470 U.S. 101 1142 E JOHNS PRAIRIE RD
City, State,Zip City, State, Zip
HOODSPORT, WA. 98548 SHELTON, WA. 98584
Phone: (360 ) 426-1284 Phone: (360) 426-1284
Email: office@bradleyaircompany.com Email:office@bradleyaircompany.com
Parcel Number: Property Address:
32331-33-00680 26470 U.S. 101 - HOODSPORT, WA. 98548
I understand I am making application for a permit to develop in a designated flood hazard area. The
undersigned agrees that all such work shall be done in accordance with the requirements of the County Flood
Damage Prevention Ordinance,building codes and all other applicable Local, State and Federal regulations.
This application does not create liability on the part of the County or any officer or employee thereof for any
flood damage that results from reliance on this application or any administrative decision made lawfully
thereunder.
Applicants Signature: Date:
Official Use:
A. Description of Work (complete for all work):
1. Proposed Development Description:
❑ New building/Addition ❑ Manufactured home ❑ Fill/grade ❑ Other:
❑ Commercial (see section D) f2-r-E I L ,
❑ Remodel/repair to existing building (see section C)
2. The parcel has b�F-
ntified in the following Flood Hazard Area:
❑ A ❑ AO ❑ VE
3. Are any other Federal, State or local permits required? Must attach copies of permits.
❑ Yes ❑ No If yes, list type:
4. Is the proposed development in an identified floodway?
Dyes ❑ No
5. If yes to#4, a No Rise Certification must be attached.
0 Yes 0 No
4. Are any other Federal. State, or local permits required? Must attach copies of permits-
171 Yes F1 No If Yes, list type-,
5. Is the proposed development in an identified floodway?
D Yes D No IF yes, a No Rise Certification must be attached.
B. Complete for Historic Structures (must be on historic registry),
1. Provide documentation of historic registry from Federal or State.
2. Provide a detailed letter requesting a variance.
Letter must include parcel number, address of site, scope of .Njork and mitigation items regarding
wetproofing or fIlDodprocifing that are available.
No work can affect or result in increase flood heights or additional threats to public safety.
All mechanical and plumbing must be flood or wetproofed.
No variances vi-ill be granted in a Floodway.
C. u-Idmng Sites:
1. A FEMA Elevation Certificate is rgWired must be, completed by a Washington State licensed Surveyor.
Elevation Certificate must be attached_
2. Base Flood Elevationi at the building site, feet NAVD 88
3. Required lov&"-st floor elevation (including basement floor): feet NAVD88
4. In flood hazard areas without a base flood elevation (BFE), vohat is the highest adjacent_
Grade?
Structure must be a minimum of two (2) feet above the HAG.
The ireWired finish floor height is
D. Complete for Alterations, Additions, or Improvements to Existing Structures:'**
1. What is the estimated market value of the existing structure? S j L4 1r)l -FIDI 0j
Attached--
>_Assessor's Parcel Detail Report OR
Appraisal from a Washington State Licensed Appraiser
0
2. What is the cosUvaluafion of the Proposed construcfiDn? $ b,7 Percentage1 5
Attached-
Contractors Bid (FEMA Criteria) OR
County Valuation per Mason County Ordinance
When d,&--cost or valluatiDn of the, proposed construction equals or exceeds 50 percent of the,market value
of the structure, then the, substantial improvernent1repair provisions shall apply.
Is the proposed work a substaffliall repairlimprovement F-1 Yes X No
0 0 WO y K:J
If yes, complete section C above. 11-ed P-
E, Complete fflr futon-Residential l"loodproofed 4Constructiom "'
1. Type of floodproc ing method:
2. The rewired fl sodproofing elevation is. lit NAVD88
3. Floodproof-ing cer0cation by a registered engineer is attached:
❑ yes ❑ No
F. nit Developments:
1. Will the subdivision or other development contain, 50 lots or 5 acres?
❑ Y'es ❑ No
2. If yes, does the plat or proposal clearly klientify base flood elevations"?
❑ lies ❑ N4
3. Are the 100 Year Floodplain and Floodway delineated on the site plan?
❑ Yes ❑ No
Administrative
Planning Staff Signature: _ �m _ Gate:
Approved- _.� Denied.
Builtiirg Staffgr. ture: _ tANN ' Qatfi: '
Approved- Denied:
Environmental Heakh off Signature: __ Date-.
Appcoved: ..__ �_�.,..�__.. Denied:
C Ammer ondit TIn ,S GU\_b�>�
-For r'1-2�1 �-ef
�-� v r I r l�-Ir' W 1 V�e,4�`-(-pc�m n o+- o-
'"A final completed FEMA Elevation Certificate must provide priar to final inspection.
Mason County FlOuti Carnage Prevention Ordinance 41.17 & International Building Co e
-Po V�J. i v) Vt-O)OUS I J s �� oY
Lky)ijr '12 Au�g a ab.
o� l , P 11 .2 Uc-I-t/'(cc�_!
�r� �Iooj wKdT'vs ,
Patti McLean Parcel Details
Mason County Assessor 32331-33-00680/2024
411 N STH ST Active
360-42 6Wo 49184 111111 11 1E1 II 111111111 II1111111111111111111 1 11
* 3 0 0 0 0 + 4 2 2 9 9 6 3
Parcel Number: Roll Year: Type: Retired: Exempt:
32331-33-00680 2024 Active No No
Assessment Type: Description
Real Property
Primary Owner Primary Situs:
SUND, SHARON J 26470 N HWY 101, HOODSPORT 98548
Legal:
TR 68 OF GOVT LOT 4 LOT 1 OF SP#1522 AF#440364
DOR: Secondary Land Code Map Number
18-Residential-All other 34 WF
Total Acres Property Class Appraiser Initials
0.35000 TX
Field Sheet
FS 00442:
District: Neighborhood
0315-Tax District 0315 N4/AREA 3
SubDivision:
Exemption Type/Level:
Frozen Value: Category '24 New Const '24 Market '24 Assessed
Estimated Exemption Amount: 0 Land: 0 114,275 114,275
Non-Senior Amount: 0 Impr: 0 1,471,250 1,471,250
Exemption Amount: 0 Perm Crop: 0 0 0
Remaining Taxable Value: 1,585,525 Total: 0 1,585,525 1,585,525
Appraisal Summary
Land ® ® 114,277
Land rx, El 128,401 + 1 128,401
Economic Adjustment A3 N4(WF)UPDATE FOR 2024 O 171 (11)1 % (14,124)
Single Family Residence Building 1 ® ® 1,457,751
Single-family Residence 0 O 894,545 + 894,545
Economic Adjustment JA3 N4(WF)UPDATE FOR 2024 O O 63 % 1 563,206
Site Improvements ® ® 13,500
Lump Sum Septic System 0 0 8,500 + 8,500
Lump Sum Water System O 0 5,000 + 5,000
ME RIMMIElw
300002 ParcelDetails www.terrascan.com
Parcel Details Printed on 4/24/2024 9:51:52 AM Page 1 of 3
B RADLE`{ Work Order
DATE 04/26/2024
AIR COMPANY
Heating I Ventilation I Air Conditioning TIME 08:00 am-09:00 am
................................
1142 E Johns Prairie Rd. DURATION 8h
Shelton, WA 98584 ....................... .............- ...............
(360) 426-1284 TECH(S) Jon Willis,John Gillham,Sabre Dahlen
office@bradleyaircompany.com ............-- ..........
JOB# 1014205958
PO#
.......................................... .. . ..........PAYMENT Direct Bill, Due Upon Receipt
CUSTOMER SERVICE LOCATION
Sharon Sund Sharon Sund
26470 U.S. 101 26470 U.S. 101
Hoodsport WA 98548 Hoodsport WA 98548
(360)490-8757 (360)490-8757
.......... ..........
JOB DETAILS Replacement of Trane heat pump system with a new Bosch M20 system. Includes removal/disposal of existing
equipment, new Honeywell controls, outdoor I pad, heat pump risers,surge protector,electrical, permits. 1
NOTES FOR Replacement of Trane heat pump system with a new Bosch M20 system. Includes removal/disposal of existing
TECHS equipment, new Honeywell controls, outdoor pad, heat pump risers,surge protector,electrical,permits.
COMPLETION
NOTES
.................-
Task Description Done
Upload photo's of job.
JOB TASKS ..........
New Maintenance Sticker/Date Existing Sticker
..........-11111111111...................
Got Parts Quote
..............I ............ .................................... ...... ..............
Description Qty Rate Total
Residential Installation Labor 32.00 $110.00 $3,520.00
Rate for installing equipment in a residence.
.............
Contracted Electrical Labor 1.00 $1,200.00 $1,200.00
Rates to hire electrician to install 240V service up to 30 Amps.
Permits 1.00 $250.00 $250.00
Mechanical Permit
....................................................................... ............................ ............. ...............-.................
RSH-50 Surge Protective Device 1.00 $94.45 $94.45
.......... ............ ......-.......... I 1.1...1----------
BVA-24WN 1-M20 1.00 $2,748.80 $2,748.80
BVA-24WNI-M20 AIR HANDLER SINGLE PIECE BOSCH 2T ECM FACTORY
...........
EHK-08B 1.00 $350.18 $350.18
EHK-08B KIT ELECTRIC HEAT 7.5KW
.......... ........................ .............
BOVA-36HDN1-M20G 1.00 $4,987.20 $4,987.20
HEAT PUMP BOSCH 20SEER 12.5EER 10.5HSPF 3T
. . . . .............................
................... ....................................................................^..............................................................................................................
'T6S,-Thermostat&6utdoor Sensor Package
(1)Redl-ink enabled Residential Thermostat $461.75
(1)Redl-ink wireless outdoor sensor
......................._............. ................ --------------
E-Lite Plastic Equipment Pad 36x36x3
E-Lite@ Plastic Equipment Pad 36x36x3-Length: 36"-Width: 36"-Height: 3"-Wt. 1.00 $80.99 $80.99
Lbs.:28
........... ............. ...............
Description Qty Rate Total
RISER,6" 4.00 $4.82 $19.28
6"One Piece Heat Pump Riser-Description:6"
...................................... ........................................................._..........._............-.,............._.-...._........._.............._..............................................._................
INC-Installation Consumables
Items used to complete installation. 1.00 $500.00 $500.00
MASON CO-2300 8.50% $1,208.08
... ...__ .... ..... ___.___ _ ....................._.......-. ..._.
SUB-TOTAL: TIME&LABOR: EXPENSES: PMTSIDEPS: TOTAL DUE:
$15,420.73 $0.00 $0.00 $10,794.00 $4,626.73
CUSTOMER MESSAGE PRE-WORK SIGNATURE 3 POST-WORK SIGNATURE
..................
Signed By: I Signed By: