Loading...
HomeMy WebLinkAboutProposed/Comparison Report - BLD Engineering / Geo-tech Reports - 2/25/1980 WATTSUN 5. 3 PROPOSED/COMPARISON REPORT 02/25/80 FILE: C: \WATTSUN5\NEWFILE HOUSE ID: PLAN 151jj HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Electric: Zoned System Efficiency: 100 % Modified Efficiency: 100% Design ACH: 0. 60 Heating Load(at 44F dt) : 15790 Btu/hr System Size: 4 . 6 kW Maximum Size @150%: 6.9 kW Average Annual Heat: 5452 kWh Annual Cost: $ 300 Ventilation System: Integrated Spot & Whole House Cooling System: NONE SEER: 0. 0 (Unducted) Cooling Load(at 4F dt) : 16363 Btu/hr Recommended Size @125%: 1.9 tons Annual cool requirement: *** kWh/yr Solar Access: Partially Shaded -------------------------------------------------------------------------------- j GLAZING ORIENTATION PROPOSED PROPOSED South 44 . 5ft2 North 44 . 5ft2 Southeast Northwest East 44 . 5 West 44 . 5 I Northeast Southwest -------------------------------------------------------------------------------- j Economic and energy consumption estimates are designed for comps tive purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. I WATTSUN 5. 3 PROPOSED/COMPARISON REPORT 02/25/80 FILE: C: \WATTSUN5\NEWFILE HOUSE ID: PLAN 1516 Site Address: Analyst: KEENAN DESIGN City, St Zip: Jurisdiction: MASON COUNTY Homeowner: SAME Utility: MASON COUNTY PUD Builder: LEMKE PROPERTIES House Type: Single Family Weather Data: Seattle, WA Comparison File: Climate Zone: 1 Heated Floor Area: 1516 ft2 The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. REFERENCE PROPOSED COMPARISON COMPONENT PERFORMANCE 257 226 *** BTU/hr-F ENERGY BUDGET 3 . 16 2 .48 *** kWh/ft2-yr PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA ------------------------------------------------------------------------------ Floor R38 vented Joist 16oc U-0. 025 1516 37.9 Glazing @12% **MILGARD PW AR/LE VINYL U-0. 330 8 . 0 2. 6 **MILGARD SL AR/LE U-0. 340 128 . 0 43.5 **MILGARD SGD AR/LE VINYL U-0. 390 42 . 0 16.4 Doors **STANLEY 6 PANEL METAL DOOR U-0. 060)y �23 1. 3 AG Wall R19 STD T1-11 U-0. 065 W78 83 . 1 Ceiling ---7Z R49 blown Attic STD baffled U-0. 027 ' � 1516 40.9 Infiltration - 7Advanced Air Sealing w/NHRV ACH-0. 300 12128ft3 ( 66.6) -- --__ Proposed UA 226 Struc Mass Light Frame, Sheetrock walls - 3 . 000 1516 4548 ---------------------------------------------------------------- - ------ Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 --------- --------- WATTSUN 5. 3 COMPONENT CHECKLIST 02/25/80 FILE: C: \WATTSUN5\NEWFILE HOUSE ID: PLAN 1516 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Electric: Zoned The heating system does not exceed: 6.9 kW. Ventilation: The ventilation system has been checked for proper operation. If designed for intermittent operation, the system is controlled automatically by a time-of-day timer set to run for a minumum of eight hours per day. If designed for continuous operation, the system is directly wired to a dedicated circuit in the electrical panel. Make-up air: Ports or registers supplying outside air in the quantity of 10 CFM are located in each bedroom and the main living area. Radon monitor: Radon monitor supplied to residents. Exhaust duct insulation: All exhaust ducts in unheated spaces are insulated to R4 . -------------------------------------------------------------------------------- _______________ Page 3 WATTSUN 5. 3 COMPONENT CHECKLIST 02/25/80 FILE: C: \WATTSUN5\NEWFILE HOUSE ID: PLAN 1516 Name: SAME Floor Area: 1516 ft2 Address: Heating Type: Electric: Zoned Reference: 1991 WA State Energy Cde ---------------------------------------------------------------------- FRAMING INSPECTION --------------------------------------------------------------------------- Approved plans: Are available onsite Air leakage: Soleplate is caulked or glued to subfloor. Rim joists between stories are caulked/sealed. All holes in building envelope (i.e. exterior ceilings, walls, and floors) are caulked/sealed, including all electrical, plumbing, j and HVAC penetrations. Outlets, switch boxes and recessed fixtures on exterior walls are caulked/sealed with approved sealant, or have foam face gaskets installed. Any recessed lights are IC rated, air tight, and sealed to the ceiling sheetrock. Wall framing: Net wall area: 1278 ft2 Standard framing with studs spaced 16" o.c. Structural panels: All structural sheathing is stamped "Exposure I" or "Exterior" . Windows: (MILGARD PW AR/LE VINYL 8 . 0 ft2) (MILGARD SL AR/LE 128 . 0 ft2) (MILGARD SGD AR/LE VINYL 42 . 0 ft2) Windows are installed as shown on the approved plans. The rough opening around windows and doors is caulked/sealed. Exhaust fans, spot ventilation: Bathroom fans are 50 CFM, kitchen fans are 100 CFM. Fan ducting has minimal bends and terminates outside of the building. The whole house exhaust fan is between 80 and 120 CFM. The whole house fan is rated at 1. 5 sones or less (unless remotely located) . INSULATION INSPECTION ------------------------------------------------------------------ Wall insulation: (R19 STD T1-11 1278 . 0 ft2) Insulation fills all exterior wall cavities. It is not compressed and is cut to fit around wires, pipes, and outlet boxes. Recessed Page WATTSUN 5. 3 COMPONENT CHECKLIST02/25/80 FILE: C: \WATTSUN5\NEWFILE HOUSE ID: PLAN 1516 fixtures in exterior walls have at least R-5 insulation behind them. j Vapor retarder: 1. 0 perm or less vapor retarder (e.g. poly, kraft j paper, perm rated paint) is installed on the warm side of insulation in floors, ceilings and walls. Air sealing: A continuous air barrier is installed over the entire inside surface of exterior ceilings, walls, and floors. Recessed lights: Any recessed light fixtures in the thermal envelope are certified under ASTM E-283 and labeled showing compliance, or are sealed around the exterior to be air tight. FINAL INSPECTION --------------------------------------------------------------------- Crawl space moisture barrier: A six mil black polyethelene ground cover is installed on crawlspace floor. Floor Insulation: (R38 vented Joist 16oc 1516. 0 ft2) Insulation is supported in a permanent manner without compression. Crawlspace ventilation: At least 5. 1 Ft2 of net free ventilation is provided in the vented crawlspace. Pipe insulation: All water pipes in unheated spaces are insulated to R-3 . Hot water: Electric water heater labeled as meeting ASHRAE Standard 90A-1980 or 1987 NAECA. Tank has R-10 non-compressible pad underneath if located over slab or in unconditioned space. Shower heads allow a maximum flow rate of 3 . 0 gallons per minute. Doors: (STANLEY 6 PANEL METAL DOOR 21. 0 ft2) Weatherstripping, threshhold, and doorsweep are properly adjusted and seal well. Ceiling: (R49 blown Attic STD baffled 1516. 0 ft2) Insulation is installed to the manufacturer's recommended density and coverage. Attic access doors are insulated and weatherstripped. I Heating system: =____________________________________ Page 2 I I ti r WATTSUN 5. 3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/25/80 FILE: C: \WATTSUNS\NEWFILE HOUSE ID: PLAN 1516 Site: Analyst: KEENAN DESIGN Jurisdiction: MASON COUNTY ( ) - Utility: MASON COUNTY PUD Homeowner: SAME House Type: Single Family Floor Area: 1516 ft2 Builder: LEMKE PROPERTIES Weather Data: Seattle, WA Climate Zone: 1 (206) 426-2170 The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. REFERENCE PROPOSED COMPONENT PERFORMANCE 257 226 Btu/hr-F ENERGY BUDGET 3 . 16 2 .48 kWh/ft2-yr REFERENCE DESIGN Reference Component Value X Area = UA ------------------------------------------------------------------------------ Floor U-0. 029 1516 44 . 0 Glazing @15% U-0. 400 227 .4 91. 0 Doors U-0. 200 21. 0 4 .2 AG Wall U-0. 058 1229 71.3 Ceiling, Attic U-0. 031 1516 47.0 Infiltration ACH-0. 350 12128ft3 ( 77.7) ---------------------------- Reference UA 257 --------------------------------------------------------------------------------- PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA ------------------------------------------------------------------------------ Floor R38 vented Joist 16oc U-0. 025 1516 37.9 Glazing @12% **MILGARD _PW AR/LE VINYL U-0. 330 8 . 0 2 . 6 **MILGARD SL AR/LE U-0. 340 128 . 0 43 . 5 **MILGARD SGD AR/LE VINYL U-0. 390 42 . 0 16.4 Doors **STANLEY 6 PANEL METAL DOOR U-0. 060 1:{� 1. 3 AG Wall R19 STD T1-11 U-0. 065 1278 83 . 1 Ceiling R49 blown Attic STD baffled U-0. 027 1516 40.9 :► U Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1