HomeMy WebLinkAboutBLD2009-00771 Detached Garage - BLD Permit / Conditions - 10/21/2009 Inspection Line(360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
Shelton,WA 98584
NIP
RESIDENTIAL BUILDING PERMIT BLD2009-00771
OWNER: RORY PETERS RECEIVED: 9/4/2009
CONTRACTOR: TIMBERLAND GARAGES 360-970-5446 LICENSE: TIMBEGL957RZ EXP: 1/2/2010 ISSUED: 10/21/2009
SITE ADDRESS: 50 W CROSSWYND CT SHELTON EXPIRES: 4/21/2010
PARCEL NUMBER: 420087890101
LEGAL DESCRIPTION: W 331.36'OF TR 10 SURV 15/150 TR 1 OF SP#2375
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
NEW DETACHED GARAGE 24' X 40' US HIGHWAY 101, L ON DAYTON AIRPORT RD, R ON DAYTON TRAILS DR,
R ON CLOVERDALE DR, L ON CROSSWYND CT TO SITE ADDRESS ON
THE RIGHT SIDE
General Information Construction&Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr..' VB
Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck:
Type of Work: ACC Fire Dist.: No. of Stories: 1 Occ. Load: Building: Garage-Detached 960
Valuation: Building Height: 17 Occ. Status: Primary Basement:
Manufactured Home Information Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: S 169.0 Ft. Shoreline: Ft. Water Body:
Rear: N 100.0 Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Shoreline Desig.: Not Applicable
Side 1: E 20.0 Ft.
Year: Serial No.: Side 2: W 258.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Plan Check Fee GMM 9/4/2009 $333.09 S12009000
EH Plan Review GMM 9/4/2009 $103.00 S12009000
Planning Review Fee GMM 9/4/2009 $205.00 S12009000
Building State Fee LDK 10/1/2009 $4.50 S12009000
Building Permit Fee LDK 10/1/2009 $512.45 S12009000
Total $1,158.04
BLD2009-00771 Please refer to the following pages for conditions of this permit. 1 of 4
CASE NOTES FOR
BLD2009-00771
CONDITIONS FOR
BLD2009-00771
1) Approv@ er dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X l
2) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered.
A. Drainfield/Reserve requires a 1 Oft setback from all footing/foundations.
B. Septic tank(s) requires 5ft setback from all footing/foundations.
C. No fo� on drains within 30ft, down gradient of drainfield/reserve area.
X
3) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647- The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
J
4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Department prioyo
ny further inspections being performed or approvals granted.
X
5) Owner/Age W
sponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of��g�oved documents will result in failure of required building inspections.
X �1I JJ
7) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use
permit shall be a for, reviewed and approved prior to the change.
X
8) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X
BLD2009-00771 Please refer to the following pages for conditions of this permit. 2 of 4
9) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
X ( '�
�T
10) Per IRC -SECTION R905 -REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in
accordan th the applicable provisions of this section and the manufacturer's installation instructions.
X
11) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement,
inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the
owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel
prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes
an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are
responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system
of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of
the building permit the owner/agent/contractor iNV-
12) owledging that all components of the stormwater management system have been installed as
approved on the stormwater site plan. X
Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other
vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2).
X IGfl�?
13) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the
international cod+�nd Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved.
X
14) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X
15) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project. 1��X
16) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinanc�gulation, must be reviewed and approved by Mason County prior to construction.
X
BLD2009-00771 Please referto the following pages for conditions of this permit. 3 of 4
17) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall be made prior to requesting additional inspections.
X
18) All property lines shall be clearly identified at the time of foundation inspection. X 22
19) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason Cou�rdinances and building regulations.
X
20) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder hM
vented action from being taken. No more than one extension may be granted.
21) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
conne (, nd flashing. Install metal connectors approved for contact with the new types of pressure treated material.
X
22) Retaining walls needed to support a surchar ch as structures, roads, or to support slopes, shall require a separate building permit and approval prior
to construction of the retaining wall. X
23) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure
these structures meet the setback conditions listed.
X 14
24) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approved 1t 2n"to ensure these structures are shown and meet the setback conditions listed.
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continua' f work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress in ti n.The owner or the agent on th wners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described property and review in n.
OWNER OR AGENT: DATE:
BLD2009-00771 Please referto the following pages for conditions of this permit. 4 of 4
I
MASON COUNTY PERMIT NO.?�0a0nq - 60'�11
BUILDING PERMIT APPLICATION -
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467• Elma (360) 482-5269 7�
On the web www.co.mason.wa.us
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner �01?-J RE E12 Company Name -T1 Ma 1-AND_ �t�fl 6
Mailin Address -,'30 V-)• .S ND CT. Mailing Address 0 • SOX Z�S
City 1— State1�N-Zip Code `I'l,Sa�i' City--Tjf O State LJPr Zip Code 1:: RS7,9
Phone Other Ph. Phone Other Ph.
Lien/Title Holder Contractor Reg. #T_%M0_',E C4AzS7eZ Exp. z
E mail address E Mail Address
Drivers Lic. # DOB Drivers Lic.# DOB
SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic
Connect to Water System Name of Water System
Well Water System Name of Water System
PARCEL INFORMATION - 12 Digit Parcel No, Fire District
Legal Description__.W 331 -Ta2. l0 S�,k12j \5/150 7 Vz- 2 of
Site Address (Please include street na e, street number and city) _
Direction§to site dtJ ko 9* -� vN -A; o�-� �c�! 0►1 IIJ.
-Pr. Q
Will timb r be cut and sold in parcel preparation? Yes/ o
Is property within 200' of Saltwater Lake River/Creek Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs > 15%
Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No
TYPE OF JOB - New Add _Alt__ Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑
Use of Building Describe Work
No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor 2nd Floor
3rd Floor Basement Deck Covered Deck Other Sq. ft.
Garage Attached Detached ,;—I- Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make Model Year
Length Width en No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price $ RtpfaGQment Unit? Yes/No
Installer Name Certification No.
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is
required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.
PROOF ONTINUATIO F W IS Y MEANS A PROGRESSJNSPECTION.
X I Date: 9
Owner/ Hers Representati / r (indic e hich one) —�— t �
FOR OFFICIAL USE BEYOND THIS POINT Accepted by: LA-_ Date
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department / i 01 Nplc- C(s-
Planning Department a
Environmental Health Department L6 00 [S
Public Works Department
Fire Marshal
FEES
Building Permit Fee Site Inspection
Plan Review Fee EH Review Fee
Plumbing & Base Fee Planninq Review Fee
Mechanical & Base fee Other
Wood/Gas/ Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal
Valuation $ TOTAL FEES
PLANNING
OWNER:
?�oYy -�e-e rs
PLANNING: SITE ADDRESS:
ALL SETBACKS ARE MEASURED S �ine� u,!R '�%5%�
s FROM THE FURTHEST
PROJECTION OF THE BUILDING TAX/PARCEL#:
HZ-OagR-69'o Ian
LEGAL:
44 33l.S fo' or- IV- :10
Lb� 330' 5uRv \5/15'0 zV--1 of
SP -#t-z3:4 5
NORTH:
APPROVED
SON COUNTY DCD PLANNING
ABA
SITE PLAN REQUIRED TO BE ON SITE _
"CHINGES SUBJECT TO APPR�-V L SCALE:
B;' Date
r (00,
I
SP�sN
�LockS �� NOTES:
Z(o9' aSg',a,�/� cZo',oa Please Contact
y"tyo - Designated
Representative, Katie
r
(10 Baumley with any
questions regarding this
application.
(360)480-1005
lLdq- A 5A
AL
GRAVVL
rAz\v6 ( Puget Sound Permits
Katie Baumley
\ P.O.Box 275,Tenino,WA 98589
(360)480-1005
katie@pugetsoundpermits.com
Precise Engineering Inc. ���
1 M I_Mellen Street Centralia, to A 9853)1 � �
-1 1 5/ Fit\ Siiii-��{iii (ilil,� G�` ,��
V
December 11, 2009 4
A13 QQ`
Timberland Garages Q
PO Box 275
Tenino, WA 98589
RE: Garage wall framing for the Rory Peters Garage
Dear Mr. Binford:
I have reviewed the drawings regarding the 2'-6" wall at the front right hand side of the
garage. The door header is not required to be continuous over this portion of wall to
maintain Elie 3-Jz`I height to width ratio.
If you have any questions, or if I may be of further help, please call me at (360) 736-1137
Sinc ely yours,
Precise neering I
HAROLD HAHNENKRATT, PE
Principal
y �
75
v/ONA1. ti
- t7-